CONTA-CONNECT. Accessories Specific to the Screw Connection System
|
|
- Scot Norton
- 6 years ago
- Views:
Transcription
1 CONTACONNECT Accessories Specific to the Screw Connection System The RK accessories programme is carefully thought out and developed with the user in mind. Numerous technical applications can be realized with a minimal expenditure for accessories. Cross connections Q/QI (Potential distribution) The screwon cross connections in the. to 0 mm range, are available as insulated (QI) and noninsulated (Q) models. Due to their angled geometry, the QIs can be arranged in a stagge pattern. This allows two potentials to be conducted parallel. A high measure of flexibility is afforded by the construction of the terminal blocks and the variability of the cross connectors. External Cross Connectors AQ/AQI blocks which have a cross connection channel or in applications in which another potential needs to be cross connected, the use of the AQIs allows this to be realized. Screw Connection System Variations Numerous RK terminal blocks are available in various standard colour variations. End Plates / Visual Separation In order to make a transition from a larger to a smaller size terminal block or to switch at the end of a terminal block, an end plate must be installed. In addition, APs influence airways and leakage paths. The potentials can be marked visually using the various choice of colours.
2 Accessories Specific to the Screw Connection System Testing / Examination With the test adapters TA, which can be attached to any number of poles by means of notched plugs, the examination of cut terminal blocks can be performed quickly and securely. Every spring terminal has a corresponding test pickup through which the potential conducting contact rail is contacted. CONTACONNECT Marking The marking / identification of the screw connection terminal blocks can be carried out using different marking systems. SB, PMC, BSTR and MC are available with standard print (neutral) or without. A number of group marking carriers are included in the delivery for marking cut terminal blocks. (see General Accessories chapter on page ) Mechanical Attachment During the manufacture of the terminal blocks, end brackets must be installed on both outer ends as a mechanical fix. For this purpose CONTACLIP offers a large number of screwon and clickon end brackets, on which group marking carriers can be attached. Special Accessories The VDE regulations require that mains terminals be cove. The AD/AD covers marked with a bolt of lightning close off the actuating channel and therefore prevents the live clamping point from being activated. Test Isolation Terminals Due to the diverse accessories programme for test isolation terminals, various switch variations are possible. The specific accessories are described based on basic switching examples. 7
3 CONTACONNECT Accessories Specific to the Screw Connection System Cross Connections Q/QI (Potential Distribution) The screwon cross connection system Q/QI allow a timesaving distribution of potentials through terminal blocks with the same crosssection range. QI is safe to contact and is available with,,, and 0 poles, as is the Q cross connection system. With the QI system, different potentials can be conducted parallel in the. mm to 0 mm crosssection range without the loss of poles. Contact terminals can generally be skipped by breaking out individual contact elements in the standard contact terminals. The cross connections can be shortened using a cutting tool, whereby attention must be paid to inserting an end plate on the side which was cut in order to maintain the rated voltage. Q/QI PreAssembled Cross Connectors In preassembled cross connectors, the cross connection rails, connecting sleeves, and attachment screws corresponding to the number of poles are already preassembled so that no parts can be lost. During installation, the preassembled cross connectors only have to be inserted in the respective terminal block. The cross connection units are available in,,, and 0 pole models. Depending on the type of terminal block, we will supply the insulated cross connector QI and/or the noninsulated cross connector Q. Q QI Cross Connections (Q/QI) of a potential through more than 0 terminal blocks. The first or the last attachment screw is screwed out of the VH from the cross connection. The QS or QI without VH are put in the middle and the two attachment screws are screwed back into the VH. Q QI Single Parts Cross Connection Q (QS + VH + BS = Q) QS cross connection rails In order to cross connect several terminal blocks maintaining the same potential, cross connection rails can be used. The cross connection rails are made of copper or bronze material. The surface is galvanized with nickel. These cross connection rails are supplied in lengths with,,, and 0 poles, in coordination with each terminal width. The cross connection rail is connected electrically to the contact rail of the terminal block by means of a connecting sleeve. For some terminal block types we supply 0. m long cross connection rails. This allows the cross connections of as many poles as desi. QS VH Connecting Sleeves The length of the VHs is coordinated with the respective terminal. They are manufactu from copper or bronze materials. The surface is nickelplated. One VH must be used for each terminal to be connected. VH BS Fixing screws In order to connect the cross connection rail to the contact rail of a terminal block with the sleeve (VH), a steel fixing screw is used. The steel screw is for the permanent mechanical connection of the cross connection unit to the contact rail. BS
4 Accessories Specific to the Screw Connection System Cross Connections Q/QI (Potential Distribution) Handling Examples Variability of the screwon cross connectors Preassembled cross connection units with,,, and 0 poles uce the installation time considerably. When using insulated cross connectors QI, there are more advantages for the terminal blocks up to 0 mm. Due to the angled construction, two QIs can be installed in a stagge arrangement. This allows two potentials to be conducted parallel. Since the QIs are insulated and, therefore, safe to contact in compliance with VDE 00 Part, no end plates or partitions for adjacent cross connections up to 00 V are needed. The QI cross connections can conduct the rated current of the terminal blocks. Skipping of terminals is possible since the individual contact bridges can be broken out of the structure. CONTACONNECT single sidebyside skipped parallel skipped extended Cross connections Q Cross connections Q (, mm ) Cross connections Q (, mm ) Cross connections Q (, mm ) Q Q Q Q 0 Q Q 0, m Voltage with without* partitions 00 V 00 V 00 V 00 V 00 V 00 V (ca. Pole+/ Pole) * DLI,/ DLIS,/ Current A A A A A A Qty. p Voltage with without* partitions Q Q Q Q 0 Q 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V Q 0, m 00 V 00 V (ca. Pole+/ Pole) * SRK,/ SRK,/ IK, IKD, Current A A A A A A Qty. p with without* partitions Q Q Q Q 0 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V Q 0, m 00 V 00 V (ca. Pole+/ Pole) RK, KBL, RKD, KBLD, * Voltage Current A A A A A Qty. p Attention: In combination with double level terminals the voltage is uced to 00 V! * All terminal blocks marked with " are absolutely safe to contact when using the corresponding cross connector as defined by the Safety Prevention Regulation "Electrical Systems and Means of Operation (VBG ) and VDE 00 Part /.. All terminal blocks marked with " are to be equipped with a cover, e.g. ADQ, EA or similar when using the corresponding cross connector, in order to guarantee contact safety. * Partitions must be inserted for adjacent cross connectors (see page )! * End plates must be inserted for adjacent cross connectors (see page )! 9
5 CONTACONNECT Accessories Specific to the Screw Connection System Cross Connections Q/QI (Potential Distribution) Cross connections Q Cross connections Q ( mm ) Cross connections Q ( mm ) Cross connections Q (0 mm ) Voltage with without* partitions Q Q Q Q 0 0 V 0 V 0 V 0 V 00 V 00 V 00 V 00 V Q 0, m 0 V 00 V Current A A A A A Qty. p (approx. poles+/ poles) * RK,/ RK,/ KBL,/ KBL, RKB RKD RKDG Attention: In combination with double level terminals the voltage is uced to 00 V! Voltage with without* partitions Q Q Q Q 0 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V Q 0, m 00 V 00 V (approx. poles+/ poles) * RK, RK, ZR RK, ZRL KBL, FF, SF, Current 7 A 7 A 7 A 7 A 7 A Qty. p Q Q Q Q 0 RK 0 KBL 0 Voltage with without* partitions 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V * Current 7 A 7 A 7 A 7 A Qty. p Cross connections Q ( mm ) Cross connections Q ( mm ) Cross connections Q ( mm ) Voltage Current Qty. Voltage Current Qty. Voltage Current Qty. with without* p. with without* p. with p. partitions partitions without* Q 00 V 00 V 7 A.0 Q 00 V 7 A 7.0 Q partitions A.0 Q 00 V 00 V 7 A.0 Q 00 V 7 A.0 Q 00 V 00 V A.0 Q 00 V 00 V 7 A 0.0 Q 00 V 7 A 0.0 Q 00 V 00 V A 0.0 Q 0 00 V 00 V 7 A 0.0 Q 0 00 V 7 A 0.0 Q 0 00 V 00 V A *.0 *.0 00 V 00 V.0 RK RK / N RK * * All terminal blocks marked with " are absolutely safe to contact when using the corresponding cross connector as defined by the Safety Prevention Regulation "Electrical Systems and Means of Operation (VBG ) and VDE 00 Part /.. All terminal blocks marked with " are to be equipped with a cover, e.g. ADQ, EA or similar when using the corresponding cross connector, in order to guarantee contact safety. * Partitions must be inserted for adjacent cross connectors (see page )! * End plates must be inserted for adjacent cross connectors (see page )! 0
6 Accessories Specific to the Screw Connection System Cross Connections Q/QI (Potential Distribution) Cross connections Q Cross connections Q ( mm ) Cross connections QI ( mm ) Cross connections QI (0 mm ) CONTACONNECT Q Q Q Q 0 RK / N Voltage with without* partitions 00 V 00 V 00 V 00 V * Current A A A A Qty. p QI QI QI QI 0 RK, RK, ZR RK, ZRL KBL, FF, SF, Voltage with without* partitions 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V * Current A A A A Qty. p QI QI QI QI 0 RK 0 KBL 0 PTK/LT PTK/QT PTK/DU Voltage with without* partitions 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V * Current 7 A 7 A 7 A 7 A Qty. p * All terminal blocks marked with " are absolutely safe to contact when using the corresponding cross connector as defined by the Safety Prevention Regulation "Electrical Systems and Means of Operation (VBG ) and VDE 00 Part /.. All terminal blocks marked with " are to be equipped with a cover, e.g. ADQ, EA or similar when using the corresponding cross connector, in order to guarantee contact safety. * Partitions must be inserted for adjacent cross connectors (see page )! * End plates must be inserted for adjacent cross connectors (see page )! Cross connection links Cross connection links are designed for pole easily separable cross connections. To be assembled with connection sleeve type VH and fixing screw BS. Cross connection link Cross connection link QL QL QL QL QL Qty. p. Connection sleeve VH VH VH 9 VH 9 VH Qty. p. Fixing screw BS BS M,x BS Mx BS Mx BS Mx Qty. p. RK, RKD RK, RK 0 RK
7 CONTACONNECT Accessories Specific to the Screw Connection System Cross Connections Q/QI (Potential Distribution) Cross connections Q / Selfassembly* Cross connections Q Cross connection rail QS Q Q Q Q 0 Q Q 0, m (approx. poles +/ poles) Cross section, mm, mm, mm, mm, mm, mm QS QS QS QS 0 QS QS 0, m Qty. p. 0 0 b,,,,,, Dimension (mm) d L d,7,7,7,7,7,7 Requi quantity Q Q Q Q 0 Q Q 0, m (approx. poles +/ poles) , mm, mm, mm, mm, mm, mm QS QS QS QS 0 QS QS 0, m ,,,,,,,7,7,7,7,7,7 Q Q Q Q 0 Q 0, m (approx. poles +/ poles) , mm, mm, mm, mm, mm QS QS QS QS 0 QS 0, m ,,,,,,7,7,7,7,7 Q Q Q Q 0 Q 0, m (approx. poles +/ poles) mm mm mm mm mm QS QS QS QS 0 QS 0, m ,,,,,,7,7,7,7,7 Q Q Q Q 0 Q 0, m (approx. poles +/ poles) mm mm mm mm mm QS QS QS QS 0 QS 0, m ,,,,, Q Q Q Q mm 0 mm 0 mm 0 mm QS QS QS QS ,,,, Q Q Q Q mm mm mm mm QS QS QS QS ,,,, Q Q Q Q mm mm mm mm QS QS QS QS ,,,, Q Q Q Q mm mm mm mm QS QS QS QS ,,,, Q f. SK / KRG SK / KRG Q f. SK / KRG SK / KRG Q f. SK / KRG SK / KRG Q 0 f. SK / KRG SK / KRG Attention: Due to construction no preassembled cross connection units possible. QS QS QS QS ,,,, * Allocation of terminals (see page 0/)
8 Accessories Specific to the Screw Connection System Cross Connections Q/QI (Potential Distribution) Connection sleeve VH BS / SS CONTACONNECT VH VH VH VH VH VH Qty. p. Requi quantity 0 Dimension (mm) d L d,,,,,, BS M,x0 BS M,x0 BS M,x0 BS M,x0 BS M,x0 BS M,x Qty. p. Dimension M,x0 M,x0 M,x0 M,x0 M,x0 M,x0 Requi quantity 0 VH VH VH VH VH VH ,,,,,, BS M,x0 BS M,x0 BS M,x0 BS M,x0 BS M,x0 BS M,x M,x0 M,x0 M,x0 M,x0 M,x0 M,x0 0 VH, VH, VH, VH, VH, ,,,,,,,,,, BS M,x BS M,x BS M,x BS M,x BS M,x M,x M,x M,x M,x M,x 0 VH, VH, VH, VH, VH, ,,,,,,,,,, BS M,x BS M,x BS M,x BS M,x BS M,x M,x M,x M,x M,x M,x 0 VH, VH, VH, VH, VH, ,,,,,,,,,, BS Mx BS Mx BS Mx BS Mx BS Mx Mx Mx Mx Mx Mx 0 VH VH VH VH ,,,, BS Mx BS Mx BS Mx BS Mx Mx Mx Mx Mx 0 VH VH VH VH ,,,, BS Mx BS Mx BS Mx BS Mx Mx Mx Mx Mx 0 VH VH VH VH ,9,9,9,9,,,, BS Mx BS Mx BS Mx BS Mx Mx Mx Mx Mx 0 VH 7 VH 7 VH 7 VH BS Mx0 SS M BS Mx0 SS M BS Mx0 SS M BS Mx0 SS M Mx0 M Mx0 M Mx0 M Mx0 M je je je je 0 BS Mx BS Mx BS Mx BS Mx Mx Mx Mx Mx 0
9 CONTACONNECT Accessories Specific to the Screw Connection System Cross Connections ZQI, (Potential Distribution) for RK,/N/Q In the terminal block RK./N/Q, the idea of the plugin cross connection from the tension spring connection system was transfer to the screw connection system. The plugin cross connection system ZQI. allows a timesaving distribution of potentials, is contact safe and is available with to 0 poles and up to 99 poles. Different potentials can be conducted parallel without the loss of poles. The cross connections can be shortened using a cutting tool. However, attention must be paid that an end plate is inserted on the side which was cut in order to maintain the rated voltage. Examples In a cross connection channel single adjacent skipped In two cross connection channels parallel/skipped parallel/extended chain jumper
10 Accessories Specific to the Screw Connection System Cross Connections ZQI, (Potential Distribution) for RK,/N/Q Variations Up to terminal blocks can be connected to each other individually with the ZQI. cross connectors listed here. Besides its flexibility, this system is distinguished by savings in the assembly time and the associated uction in costs. CONTACONNECT ZQI,/ ZQI,/ ZQI,/ ZQI,/ ZQI,/ ZQI,/ ZQI,/7 ZQI,/ ZQI,/9 ZQI,/0 Voltage 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V 00 V Current A A A A A A A A A Qty. p
11 CONTACONNECT Accessories Specific to the Screw Connection System Insulated External Cross Connectors AQI External cross connecting bridges allow the potential to be branched at terminal blocks which have no internal cross connection channel. The AQI is an external cross connector coated in polyamide.. When external cross connections are used, the nominal crosssection is uced to the next smallest conductor. Insulated External Cross Connectors AQI AQI assembled AQI AQI // AQI // AQI // AQI 0// Qty. p. 0 0 Spacing mm SRK,/ SRK, RKD, IK, IKD, BKA, SRK,/ SRK, RKD, IK, IKD, BKA, SRK,/ SRK, RKD, IK, IKD, BKA, SRK,/ SRK, RKD, IK, IKD, BKA, AQI // AQI // AQI // AQI 0// RK, RK,/ N/Q RK, RK,/ N/Q RK, RK,/ N/Q RK, RK,/ N/Q AQI // AQI // AQI // AQI 0// RK,/ RK, RKB RKD BKA VMAK, RK,/ RK, RKB RKD BKA VMAK, RK,/ RK, RKB RKD BKA VMAK, RK,/ RK, RKB RKD BKA VMAK, AQI //7 AQI //7 AQI //7 AQI 0// RK, RK, ZR RK, ZRL TRK, RK, RK, ZR RK, ZRL TRK, RK, RK, ZR RK, ZRL TRK, RK, RK, ZR RK, ZRL TRK, AQI // AQI // AQI // RK 0 KBL 0 BKA 0 RK 0 KBL 0 BKA 0 RK 0 KBL 0 BKA 0 RKDG Insulated External Cross Connectors AQI AQI assembled AQI AQI 7// AQI 7//7 AQI 9// AQI 9// Qty. p Spacing mm RK,/ RK, RKB RKD BKA VMAK, RK, RK, ZR RK, ZRL TRK, SRK,/ SRK, RKD, BKA, OK, IKD, RK, RK,/N/Q
12 Accessories Specific to the Screw Connection System NonInsulated External Cross Connectors AQ External cross connecting bridges allow the potential to be branched at terminal blocks which have no internal cross connection channel. The AQ type is supplied with poles. Contact elements can be broken out easily by hand. The stickon insulation section IP is available for AQ. When external cross connections are used, the nominal crosssection is uced to the next smallest conductor. CONTACONNECT Insulated External Cross Connectors AQ AQ assembled AQ + IP AQ ( poles) AQ ( poles) IP Qty. p Spacing mm Length mm 0 0 Description Straight model Angled model Insulation section can be installed later as contact safety! RK 0 KBL 0 SIK 0 PTK Bridgeable PEN feedin blocks If electronic controls are of the conductor network feedin design and are connected conductor to an energy supply network, then a conductive connection must be created from the earth terminal SL to the neutral terminal N. This is fulfilled by the external cross connector AQV PEN. Bridgeable PEN feedin blocks AQV assembled AQV AQV PE/N 0 AQV PE/N AQV PE/N Qty. p SL 0/ and RK 0 SL 0/ and RK 0 SL / and RK / SL / and RK SL / and RK / SL / and RK For all other technical data and dimensions of the terminal blocks mentioned, please consult the corresponding page in the catalogue. 7
13 Specific accessories to the Screw connection system Feedthrough terminals / without rail contact/without PE function Screw connection system RK, PE RK,/PE CONTACONNECT RK 0/PE RK / N/PE Insulating terminal housing PA. V Rail mount on TS / TS M, M M M Connection diagram Feedthrough terminal connectors Feedthrough terminal connectors Feedthrough terminal connectors Feedthrough terminal connectors Connection type Dimension (L x W x H) with TS mm with TS x 7, mm / / /Qty. p. Rating Rated conductor crosssection mm /AWG Rated surge voltage kv/contamination degree Gauge plug acc. to EN 0 97 / Flammability class UL 9 For certifications and approvals Conductor data Single wire (solid)/stranded (flexible) mm Flexible/Flexible (with ADH acc. to DIN /) mm Contact wire range mm Insulation stripping length mm Features Number of cross connection channels Accessories End plate AP /Qty. p. /Qty. p. Partition plate TW /Qty. p. /Qty. p. Insulation plate TRS /Qty. p. Cross connector Q/Insulated cross connector QI /Qty. p. Cross connector Q/Insulated cross connector QI /Qty. p. Cross connector Q/Insulated cross connector QI /Qty. p. Cross connector Q/Insulated cross connector QI /Qty. p. Cross connector Q/Insulated cross connector QI /Qty. p. Cross connector Q/Insulated cross connector QI /Qty. p. Cross connector Q/Insulated cross connector QI /Qty. p. Cross connector Q/Insulated cross connector QI /Qty. p. External insulated cross connector AQI poles /Qty. p. External insulated cross connector AQI poles /Qty. p. Cover AD /Qty. p. Inlay profile EP /Qty. p. Hexagon socket screw key ISKS /Qty. p. Screw driver /Qty. p. Screw connection technology x x, x x 7 RK,/PE./, A V 0, 0, 0,, 7 AP,0 0./ 0./ TW,0 0./ 0./ TRS./ Q 7.0/ Q.0/ Q 9.0/ Q /0 SDB 0,x 0.0/ Screw connection technology x x, x x 7 RK,/PE./ 0 A V 0, 0, 0, AP,0 0./ 0./ TW,0 0./ 0./ TRS 0./ Q 9.0/ QI 70./ Q.0/ QI 7./ Q.0/ QI 7./ Q 0.0/0 QI 0 7./0 SDB 0,x, 0.0/ Screw connection technology x x, x x 7 RK 0/PE./ 0 A V 0,0 0,0 0,0 0,0 AP,0 0./ 0./ TW,0 0./ 0./ TRS 0./ Q 0.0/ QI 7./ Q.0/ QI 7./ Q.0/ QI 7./ Q 0.0/0 QI 0 7./0 SDB 0,x,0 07.0/ Screw connection technology x,9 x 7 RK / N/PE./ B7 V,,,, Q 7.0/ Q.0/ Q.0/0 Q 0.0/0 SDB 0,x,0 07.0/ Further accessories Further accessories like marking systems, test adapters, covers, end brackets etc. you can find on the pages for accessories specified below! Page Page Page Page
14 RK / N/PE RK /PE RK 9/PE RK /PE RK 0/PE M M M M 0 M 0 CONTACONNECT Feedthrough terminal connectors Feedthrough terminal connectors Feedthrough terminal connectors Feedthrough terminal connectors Feedthrough terminal connectors Screw connection technology Screw connection technology Screw connection technology Screw connection technology Screw connection technology x x 7 x x 79 x x 7, x x 9 x x, 9 x x, 9 x x, 9 x x 9 x x, RK / N/PE./ RK /PE 7./0 RK 9/PE./0 RK /PE 9./ RK 0/PE 70./ B9 V /0 B0 V 9 /0 B V 00 B V 0 0/0 B V,,,, Q.0/ Q.0/ Q.0/0 Q 0 7.0/0 SDB,x, 0.0/ AQI / 7./ AQI / 7./ AD / B 0.0/ EP 7.0/0 ISKS./ AQI /9 7./ AQI /9 7./ AD /9 B 0.0/ EP 9 7.0/0 ISKS 77.0/ AQI / 77./ AQI / 7./ AD / B 0.0/ EP 77.0/0 ISKS 77.0/ AQI /0 79./ AQI /0 770./ AD /0 B 0.0/ EP 0 0.0/0 ISKS 77.0/ Page Page Page Page Page 9
15 CONTACONNECT Accessories Specific to the Screw Connection System Screw Connection System Variations The following colour variations are standard colour variations. On demand and dependent on previously determined batches individual colour variants are feasible. SRK,/ SRK,/ SRK,/ SRK,/ SRK,/ SRK,/ SRK,/ SRK,/ SRK, SRK, SRK, SRK, SRK, SRK, SRK, SRK, RK, RK, RK, RK, RK, RK, RK, RK, RKD, RKD, RKD, RKD, RKD, RKD, RKD, RKD, RK, RK, RK, RK, RK, RK, RK, RK, RKD RKD RKD RKD RKD RKD RKD RKD Qty. p. Techn. spec. see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page see page see page see page see page see page see page see page see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page see page see page see page see page see page see page see page RK,/ RK,/ RK,/ RK,/ RK,/ RK,/ RK,/ RK,/ RK, RK, RK, RK, RK, RK, RK, RK, RK,/N/Q RK,/N/Q RK,/NQ RK,/NQ RK,/NQ RK,/NQ RK,/NQ RK,/NQ RKD,/ RKD,/ RKD,/ RKD,/ RKD,/ RKD,/ RKD,/ RKD,/ RK,/ RK,/ RK,/ RK,/ RK,/ RK,/ RK,/ RK,/ RKD / RKD / RKD / RKD / RKD / RKD / RKD / RKD / Qty. p. Techn. spec. see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page see page see page see page see page see page see page see page see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page 7 see page see page see page see page see page see page see page see page RK 0 RK 0 RK 0 RK 0 RK 0 RK 0 RK 0 RK 0 RK RK RK RK RK RK RK RK RK RK RK RK RK RK RK RK RK 0/ RK 0/ RK 0/ RK 0/ RK 0/ RK 0/ RK 0/ RK 0/ RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N RK / N Qty. p.. Techn. spec. 0
16 Accessories Specific to the Screw Connection System End Plates / Visual Separation AP end plates are usually inserted at the end of a clamp point. If work is carried out within a terminal block with different / various sized terminal blocks, end plates must also be inserted in order to ensure contact protection and the safety of the fingers. The outer dimensions of the end plates correspond to the dimensions of the terminal blocks. Colou end plates are often inserted in order to mark a clear distinction between different power circuits or voltage levels. In addition, the use of end plates lengthens the airways and leakage paths, which in turn influence the rated voltage. Rapid installation of the end plates is enabled by notched plugs. Due to the special construction of the RK series, no end plates must be inserted for adjacent QI cross connectors with different potentials. End plates for standard terminal blocks SRK/RK/TSK/FF/SF/PTK AP,/ AP,/ AP,/ AP,/ AP,/ AP,/ APSR APSR APSR APSR APSR APSR AP, AP, AP, AP, AP, AP, AP,0 AP,0 AP,0 AP,0 AP,0 AP,0 AP AP AP AP AP AP AP,/R AP,/R AP,/R AP,/RL AP,/RL AP,/RL AP/L/Q/D Width, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm Qty. p. End plates for double level terminal blocks RKD TYPE AP AP AP AP AP AP APG APG colour Width, mm, mm, mm, mm, mm, mm, mm, mm Qty. p. SRK,/ SRK,/ SRK,/ SRK,/ SRK,/ SRK,/ SRK, SRK, SRK, SRK, SRK, SRK, RK,/ RK, RK,/ RK, RK,/ RK, RK,/ RK, RK,/ RK, RK,/ RK, RK, RK 0, TSK, FF, SF RK, RK 0, TSK, FF, SF RK, RK 0, TSK, FF, SF RK, RK 0, TSK, FF, SF RK, RK 0, TSK, FF, SF RK, RK 0, TSK, FF,SF RK RK RK RK RK RK RK, ZR RK, ZR RK, ZR RK, ZRL RK, ZRL RK, ZRL PTK RKD, RKD RKD, RKD RKD, RKD RKD, RKD RKD, RKD RKD, RKD RKDG RKDG End plates for three level terminal blocks IKD/VMAK/IK/DLIS/DLI AP/ID, AP/ID, AP/ID, AP/VMAK AP/VMAK AP/VMAK AP/I, AP/I, AP/I, AP, S AP, D Width, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm, mm Qty. p. IKD, IKD, IKD, VMAK, VMAK, VMAK, IK, IK, IK, DLIS, DLI, End plates for disconnect and fuse terminal blocks STK/TK/STKD/SIK/SK AP/SI AP/SI AP/SI AP/SI AP/SI AP/SI AP/SID AP/SID AP/SID AP 0 AP 0 AP 0 AP/SIKRG AP/SIPA Width, mm, mm, mm, mm, mm, mm, mm, mm, mm mm mm mm mm mm Qty. p. STK TK STK TK STK TK STK STK /K STK STK /K STK STK /K STKD STKD /K STKD STKD /K STKD STKD /K SIK 0 SIK 0 SIK 0 SK SK CONTACONNECT
17 CONTACONNECT Accessories Specific to the Screw Connection System Single and fourfold covers The VDE regulations require that network connection terminals be cove. The covers marked with a bolt of lightning or the covers EA and AD close off the actuating and cross connection channels of the terminal block, thus preventing the activation of the live clamping point. The EA and AD covers are pushed onto the terminal blocks from above until they catch. The variation can be labelled using the marking pen BS or the marking system EMS. The AD s, which are designed with the appropriate crosssection for four terminal blocks, are fixed mechanically by means of two plastic screws. Two variations of overprint [German and English ( /E)] are available. Single cover EA EA EA EA EA /B EA /B EA /B Qty. p. Marking neutral neutral neutral RK, RK, RK 0 RK, ZR RK, ZRL FF, SF, SL, SL SL 0 Single cover AD AD / AD /N AD / AD / AD / N AD / N AD / AD / AD / B AD / N/B AD / B AD / B AD / N/B AD / N/B AD / B AD / B AD / B AD /9 B AD / B AD /0 B Qty. p. Marking neutral neutral neutral neutral neutral neutral neutral neutral RK, KBL, RK, N Q RK, KBL, RK 0 KBL 0 RK / N RK / N RK RK RK, KBL, RK, N Q RK, KBL, RK 0 KBL 0 RK / N RK / N RK RK RK RK 9 RK RK 0 Fourfold cover AD AD / B AD / B AD / B AD / B AD / B/E AD / B/E AD / B/E AD / B/E Qty. p. Marking Fixing screw BSK M, x BSK M, x BSK M x BSK M x BSK M, x BSK M, x BSK M x BSK M x Qty. p. RK, KBL, RK, RKD KBL, KBLD RK, KBL, RK 0 KBL 0 RK, KBL, RK, RKD KBL, KBLD RK, KBL, RK 0 KBL 0 Cross Connection Channel Covers AD Q For the RK., RK 0, RK. ZRL, FF. and SF. terminal blocks, 0 mm long covers are available which can be used to protect against contact when using noninsulated cross connectors. The section consists of polamide. and is supplied in the colours transparent and. Cross Connection Channel Covers AD Q AD Q transparent AD Q Qty. p. transparent RK, RK 0 RK, ZR RK, ZRL FF, SF, RK, RK 0 RK, ZR RK, ZRL FF, SF,
18 Accessories Specific to the Screw Connection System Cover Section AD in combination with the partition TWMF Several safety regulations, for example "Electrical Systems and Means of Operation (VBG ) and VDE 00 Part /., require that contact with the live parts of electrical means of operation must be protected against. In terminal blocks this protection must be provided by additional covers of cross connectors Q or test jacks are used. For this purpose there are cover sections with assigned support brackets which can be used on the most important terminal sizes. The support brackets can be arranged at the end of the terminal or dispersed. They can be attached to the mounting rail TS or TS. CONTACONNECT TWMF AD TWMF TWMF TWMF AD /0 mm Qty. p. m transparent Partitions TW When cross connections are used, partitions must be inserted between the noninsulated cross connectors as a rule. This is requi to maintain the necessary airways and leakage paths. Partitions TW TW, TW,0 TW TW TW, TW,/ Qty. p. RK, RK,/ KBL, KBL,/ RKB FF / RK, KBL, RK, RK 0 KBL, KBL 0 SL SL / SL 0 SL 0/ FF, SF, RK RK SRK,/ SRK, Insulation plates TRS When cross connections are used, insulation plates are used with some types of terminals in order to maintain the necessary airways and leakage paths. Partition chips can be inserted between the cross connectors at a later point in time. Insulation plates TRS TRS TRS 0.. Qty. p. RK, RK 0 RK KBL, KBL 0 RK,/ KRG RK / KRG RK / KRG RK 0/ KRG RK / KRG PTK RK,/ KBL,/ RK, KBL, RK, KBL, RKD, KBLD, RKD KBLD DLIS, DLI, Connection Sleeves VBS Connection sleeves for joining two or three levers of the of the fuse disconnecting terminals STK and SIK 0 or SIK 0Z and STRD. The VBS plastic sleeves are pushed onto the levers from the side, combining them mechanically into two or three pole units. This allows the simultaneous disconnection from multipole power circuits. Connection Sleeves VBS VBS /0 VBS /0 VBS /0Z VBS /0Z Qty. p. SIK 0 STK / STKD SIK 0 STK / STKD SIK 0 / Z SIK 0 / Z
19 CONTACONNECT Accessories Specific to the Screw Connection System Testing / Examination Test adapter TA With the test adapter TA, which can be attached to any number of poles by means of notched plugs, the examination of cut terminal blocks can be performed quickly and securely. Wires in the 0. to.0 mm crosssection range can be crimped or solde by means of the spring action sensor stylus. The test adapters contact the screw head, cross connection or contact plate, depending on the model. The test adapter sets consist of a housing, spring, and sensor stylus. An end plate is supplied in addition with the TAD models. All test adapters can be marked by means of the quick identification system PMC. Test adapter TA TA /NQ TS /ST TA /Q TA /ST TA /Q Dimension Height dimension to be added to the corresponding terminal block in mm Length mm Modular width mm /Qty. p. Conductor data Flexible / flexible (with ADH acc. to DIN /) mm Insulation stripping length mm TA /NQ.0/0 0, RK,/N/Q, 7, TS /ST.0/0 0, RK,, 7, TA /Q.0/0 0, RK,, 7, TA /ST.0/0 0, RK,, 7, TS /Q.0/0 0, RK, Test adapter TA TA /ST TA /Q TAD /S TAD /S Dimension Height dimension to be added to the corresponding terminal block in mm Length mm Modular width mm /Qty. p. Conductor data Flexible / flexible (with ADH acc. to DIN /) mm Insulation stripping length mm, 7, TA /ST 7.0/0 0, RK 0, 7, TA /Q 7.0/0 0, RK ,7 TAD /S.0/0 0, RKD, 9 77,7 TAD /S.0/0 0, RKD
20 Accessories Specific to the Screw Connection System Testing / Examination Test Plugs PS The test plugs PS. and PS allow a direct measurement at the contact rail of the respective screw connection terminals in the. mm and mm crosssection range. As opposed to the test adapters TA, the test plugs PS do not click into place mechanically with the terminal. The adapter plug ZS./ allows the transition from a mm. CONTACONNECT Test Plugs PS PS. PS ZS./ /Qty. p. In combination with jack STB PS. 07.0/ STB./. (7.0) STB /. (0.0) STB (7.0) STB 7 (7.0) PS.0/ STB / (.0) STB / (7.0) ZS./.0/ STB / (.0) STB / (7.0) ATTENTION: See also accessories specific to the tension spring connection system, test plugs, page 70. Socket contacts STB Cocket contacts STB are screwed into the contact rail or in place of the terminal screw in the terminal blocks. The test plugs PS are inserted into them. Socket contacts STB STB STB./. STB /. STB / STB / STB STB 7 /Qty. p. 7.0/ 0.0/.0/ 7.0/ 7.0/ 7.0/ L, 7 L, 7, 9,, Dimension mm L L d d,, 7,, d M, Jacks STB 0, STB 0, STB 0, STB 0, grey STB 0, STB 0, STB 0, STB 0, STB 0, violett /Qty. p..0/.0/.0/.0/.0/ 7.0/.0/ L 0, 0, 0, 0, 0, 0, 0, L L Dimension mm L d,,,,,,, d d 7, 7, 7, 7, 7, 7, 7, M
21 CONTACONNECT Accessories Specific to the Screw Connection System Test Disconnection Terminals PTK Test disconnection terminals are used primarily in the area of electricity generation and supply. They are tailo to the various prevailing switching requirements of the current transformer secondary circuit. When replacing measuring instruments, electricity meters and when making comparative measurements, current transformers must exhibit a closed secondary circuit. CONTACLIP test disconnection terminals are available in the following three models Socket conects can be attached to all models for a test pickup using the test plug PS. All models are contact safe in compliance with VBG. The current or voltage paths are disconnected by means of a permanent sliding disconnector. The switch position can be seen readily at all times, since the disconnection screw has a insulation casing. Necessary products for basic switching examples. PTK/LT PTK/DU AP/L/Q/D STB / QVS VH 9 STB Quantity PTK/QT AP/L/Q/D STB / QSB Quantity PTK/LT PTK/QT PTK/DU AL/L/Q/D STB / STB 0, QS VH BS M x QSB Quantity
22 Accessories Specific to the Screw Connection System Test Disconnection Terminals Accessories Cross switches QVS Cross switches In order to attach the cross switch bridge QVS, connection sleeves VH 9 and attachment screws BS or jacks STB are needed. The attachment screws and jacks are available with and without colour markings. QI QSB QVS VH 9 CONTACONNECT /Qty. p. /Qty. p. /Qty. p. /Qty. p. QI 7./ QI 7./ QI 7./ QI 0 7./0 QSB 7.0/ QSB 7.0/ QSB 7.0/ QVS 97.0/ QVS 9.0/ QVS 99.0/ VH 9.0/ Socket contacts STB In the test disconnection terminals, the test plugs PS or the short circuit plugs KSS are inserted into the socket contacts STB. Socket contacts STB are also used when testing has to take place at the same time the QVS is used. Socket contacts STB STB / BS BS Socket contacts STB / Socket contacts STB / can be screwed into the cross connection channel. The test plugs PS or the short circuit plug KSS are inserted into the jacks. /Qty. p. /Qty. p. /Qty. p. /Qty. p. STB.0/ STB.0/ STB violett 9.0/ STB /.0/ BS.0/ BS.0/ BS violett.0/ BS 0.0/ Test Plug PS The test probe PS serves the final testing of wi test switches. A cross connection between the two PTK terminals can be established with the short circuit plug KSS. Test Plugs PS KSS /Qty. p. /Qty. p. /Qty. p. /Qty. p. PS.0/ KSS.0/0 7
Content. Accessories I.1
Content Accessorries Overview.2 -.3 Visual separation side covers.4 -.5 Colour coding options.6 -.7 Potential distribution.8 -.13 Testing/Checking.14 -.15 Protective covers.16 -.18 for modular disconnect
More informationAccessories. Contents. Accessories. Accessories I.1
Contents Overview.2 Visual separation side covers.4 Colour coding options.6 Potential distribution.8 Testing/Checking.14 Protective covers.16 for modular disconnect test terminals.20.1 Overview The extra
More informationFeed-through terminal, 4 mm², Screw connection, Wemid, dark beige, TS 35
General ordering data Order No. 1020100000 Part designation WDU 4 Version EAN 4008190150617 Qty. 100 pc(s). Feed-through terminal,, Screw connection, Wemid, dark beige, TS Product notes Note, ordering
More informationHARTING Ethernet cabling cables and connectors, 4 wire
Industrial Cat. 5e Standard cable, 4-wire Type A for permanent installation or to build-up PROFINET system cables PVC X 8 wire X Cat. 5e X Cat. 6 Cat. 6 A Cat. 7 Cable structure Core structure Wire insulation
More informationFeed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35
General ordering data Order No. 1020000000 Part designation WDU 2.5 Version EAN 4008190099633 Qty. 100 pc(s). Feed-through terminal,, Screw connection, Wemid, dark beige, Product notes Note, ordering data
More informationCONTACT-DUO-PROFILE. Contact-Duo-Profile overview
13 6.3 13 6.3 4.7 20.7 24.6 +1/-0 24.6 +1/-0 2.5 24.6 +1/-0 20.7 4.3 +0.3-0.4 3.6 ±0.3 32.5 32.5 32.5 5 2 CONTACT-DUO-PROFILE Contact-Duo-Profile overview 13 6.3 13 6.3 4.7 2.5 16±0.8 4.7 2.5 4.7 2.5 2.6
More informationExtra functions. Accessories W-Series. Terminals, W-Series. Visual separation Side covers Page E.98
Accessories W-Series xtra functions Weidmüller offers the user of W-Series s a comprehensive range of accessories, providing optimum solutions to every conceivable task even outside the range of standard
More informationGrounding-type plugs and sockets K Product information
Product information Plugs and sockets for harsh conditions. SCHUO by MENNEES with the hammer symbol. Acc. to VDE 0105 part 115. Made of high-grade AMAPLAST. Acc. to VDE 0620 for harsh conditions. Application
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationPanel-mounting Thermostats EM Series
Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page /2 Panel-mounting Thermostats EM Series with, 2, 3 or 4 single-pole snap-action
More informationAutomatic Test System AT-S + with STAR + Technology Features
AT-S + with STAR + Technology Features AT-S + offers all the known benefits of our STAR technology, now also for AC safety power sources. It is the perfect symbiosis of CEWA GUARD and STAR technology.
More informationPanel-Mounted Thermostat
Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief
More informationConnecting cables NEBS, for sensors
Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Product range overview Function Version Type code Connection technology (Electrical connection 2) Connecting cable Cable characteristic
More informationElectromechanical Relays
Industrial Plugin Electromagnetic Relays Description Relays of general application - the new relays are distinguished by a modern design, high reliability and functionality. Modern technology ensures high
More information10 PDUs 19 PDUs Zero-U PDUs
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com 10 PDUs Page 1. GENERL CHRCTERISTICS...1 2. EQUIPMENT ND PERFORMNCE...3
More informationPATCH PANEL Easy Patch INSTRUCTION MANUAL
Page 1 BDA82-0 PATCH PANEL Easy Patch 96 Bantam (TT) Jacks 50 pin D-subminiature NPPA-TT-SD50 Easy Patch NPPA-TT-SD50 Page 2 BDA82-0 Index page 1 Electrical configuration 3 2 Re-Configuration and Replacement
More informationConnecting cables for valves, round plug connectors Product range overview
Connecting cables for valves, round plug connectors Product range overview Version Type code Connection technology (Electrical connection 2) Electrical connection 1: socket M8x1 4-pin NEBV-M8W4L Plug M8x1,
More information3 Cleaning. 4 Technical data
EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution
More informationKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More information-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.
Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.6 N LE 3 NEBV Connecting cables for valves Connection technology on left, field device side B2 Socket type B to industry standard,
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors
Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our
More informationPushbutton Units and Indicator Lights
Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded
More informationConnecting cables for valves, Sub-D Type codes
Type codes NEBV C S1 G 44 K Function NEBV Connecting cables for valves Product design Standard C Easy to clean design Connection technology, left, field device side S1 S7 Sub-D socket Sub-D HD socket Cable
More informationNational Wire and Cable and National Cable Molding Headquarters Los Angeles California
National Wire and Cable and National Cable Molding Headquarters Los Angeles California CAPABILITIES Medical Business Machines Communications Equipment Computer Equipment Audio Systems General Instrumentation
More informationMax. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm
21.610/1 RAK: Universal thermostat How energy efficiency is improved Demand-led controlling, monitoring and limiting, without auxiliary energy. Areas of application For controlling and monitoring the temperature
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationAutomatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces
Automatic s 2004 Automatic. All rights reserved. pdf 1.0 3-18-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable Plugs...................
More informationConnecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath
Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803
More informationVIP-2/SC/FLK20. Extract from the online catalog. Order No.:
Extract from the online catalog VIP-2/SC/FLK20 Order No.: 2315049 The illustration shows a 16-position version VARIOFACE module, with screw connection and flat-ribbon cable plug connector, for mounting
More informationPre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports
RJ45 - Cat. 6A Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports Compatible with FO trunks Modern data centre trunk solution in modular cassette technology Pre-terminated
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More information1.2 EUREKA Series... from page c.14
.2 EUREKA Series................................................................................................. from page c.4 This latest generation of industrial plugs, connectors and socket outlets
More informationVIP-3/SC/FLK40. Extract from the online catalog. Order No.:
Extract from the online catalog VIP-3/SC/FLK40 Order No.: 2315078 VARIOFACE module, with screw connection and flat-ribbon cable plug connector, for mounting on NS 32 or NS 35/7.5, with pin strip and short
More informationInstallation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.
www.wampfler.com Page 1 of 27 Index Page 1 Basics...4 2 Basic understanding of an IPT -system...5 3 General rules regarding metal parts in close proximity...6 3.1 Envelope free of ferromagnetic material...6
More informationAmphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics
Amphenol C 6- / C 6- Circular Circular Connectors Connectors Amphenol-Tuchel Electronics General information We reserve the right to change the design due to improvement in quality, development or production
More information3M Locator Plate N
M Locator Plate 44-107N Instructions for the assembly of.100 x.100 preassembled socket connectors 1.0 General The M Locator Plate 44-107N is designed to aid in the assembly of the preassembled socket connector
More informationConnectors for mains connection IEC
Connectors for mains connection IEC 60947-5-2 Product description Compact connectors for mains and control lead connections. Robust design, by a safety bracket, vibration-proof plug connection, can be
More informationHN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/
Connectors Introduction 2004 Automatic Connector. All rights reserved. pdf 1.0 4-13-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable
More informationLCS2 Cat. 6 RJ 45 Patch panels and units
87045 LIMOGES Cedex Telephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88 LCS2 Cat. 6 RJ 45 CONTENTS Page 1. General characteristics....1 2. Presentation...2 3. Installation...2 4. Technical characteristics...2
More informationLCS 2 RJ 45 Cat. 6A HD panels and units
87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Page 0 335 85/86 1. General characteristics....1 2. Presentation...1 3. Positioning...1 4. Technical characteristics...1
More informationSTE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance
Technic Cross-Flow Fans T R A N S F O R M E R C O O L I N G S O L U T I O N S Transformer Cross-Flow Fans General Information provides optimal solutions for air forced cooling of transformers. High performance
More informationCANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR
CANNON STANDARD page 1 of 18 1 General Information... 2 1.1 Scope... 2 2 Ordering Code... 3 2.1 Housing / Motor Side... 3 2.2 Cable Side... 3 3 Explosion Drawing... 3.1 Explosion Complete Assembly... 3.2
More informationIdentification - electrical services
Identification - electrical services Aesthetic All live phase cable sheathing to be brown coloured and neutral phase cable sheathing to be blue coloured, all labelled L1, L2, L3 & N respectively in accordance
More information19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43
19" TiRAX cabinet system from page 3 19" NETcell cabinet system from page 31 Open 19" racks from page 43 all-mounting/stand-alone distribution systems from page 53 all-mounting enclosure systems from page
More informationMID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J
MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationCOMBINATION UNITS MARCH 2018
COMBINATION UNITS MARCH 2018 2 COMBINATION UNITS STATIONARY SOCKET OUTLET COMBINATIONS Variants 5 Dimensions 6 Wall-mounted Distributor Boxes (plastic) Series 45 8 Wall-mounted Distributor Boxes (plastic)
More informationElectromechanical Relays
Electromechanical Relays Industrial Plugin Electromagnetic Relays Description Relays of general application - the new relays are distinguished by a modern design, high reliability and functionality. Modern
More informationOperating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics
Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective
More informationLevel Measurement silometer FMC 420, FMC 423
Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level
More informationPivot Power RJ45 Modular Plug Connectors
Pivot Power RJ45 Modular Plug Connectors Application Specification 114-32052 07 OCT 13 i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters
More informationNewScope-7A Operating Manual
2016 SIMMCONN Labs, LLC All rights reserved NewScope-7A Operating Manual Preliminary May 13, 2017 NewScope-7A Operating Manual 1 Introduction... 3 1.1 Kit compatibility... 3 2 Initial Inspection... 3 3
More informationLED MODULES READYLINE DL
LED MODULES READYLINE DL BUILT-IN MODULE LED-MODULE READYLINE DOWNLIGHT DL WU-M-538 / WU-M-539 / WU-M-540 Typical Applications Downlights Replacement for CFL DIRECT MAINS CONNECTION REDUCED FLICKER HIGH
More informationHinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA
Hinges with built-in safety multiple switch SUPER ECHNO POLYMER IP RoHS PA +0-0 MAERIAL Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black or grey colour RAL 00 (C). Rotation pin: glass-fibre
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63
Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC
More informationConnecting cables for valve terminals, M9x0.5 Type codes
Type codes KVI CP 3 KVI Connecting cables for valve terminals Usage CP CPI interface Cable characteristic 3 Suitable for energy chains Connection technology on the left, field device side GS WS Straight
More informationIntroduction. Audio Normalling
Patch Panels 119 Content Page NPPA-Series - 96 Bantam (TT) Jacks... 121 NPP-TB-Series - 48 B-Gauge Jacks... 123 1/4" Patch Panel... 125 MA 96 and XPM 96 Bantam Patchbays... 127 LF 48 B-Gauge Patchbays...
More informationControl cabinet interface and cable entry systems
Modlink MPV Control cabinet interface The Modlink MPV control cabinet interface provides the connection from the control cabinet to the fieldbus environment (outside) in a simple way. Durable connection
More informationwww.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~
More informationTender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*
Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* General Scope of Work: Supply and installation of Computer Laboratory setup in MIU Location of Installation:
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationCatalog. Industrial Plugs & Sockets The complete range
Catalog Industrial Plugs & Sockets The complete range Contents Type Page Introduction... 4 IEC 60309-2 (clock)... 5 Product overview Critical & Safe... 6 Tough & Safe... 7 Easy & Safe... 8 Plugs Splashproof...
More informationSensor technologies Proximity sensors Series ST4. Brochure
Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationSTB Distribution Box Screw or IDC Type Indoor DP Outdoor DP Wall & Pole DP Pillar DP
Distribution Boxes STB Distribution Box Screw or IDC Type Indoor DP Outdoor DP Wall & Pole DP Pillar DP BOOK 1.indd 27 9/22/10 7:22:14 PM STB Distribution Box for Telecommunication 2 Pair Distribution
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationABB i-bus EIB Universal dimmer 6155 EB for Installation
73-1 - 5975 23459 ABB i-bus EIB Universal dimmer 6155 EB - 101-500 for Installation Operating instructions only for authorized, skilled electricians with EIB training Important instructions Attention It
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A
More information-V- New. Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.
Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803
More information12G Broadcast connectors
12G Broadcast connectors Delivering 12G in a single punch www.coax-connectors.com Welcome to COAX 12G BNC Plug return loss COAX Connectors Ltd is a leading UK designer, manufacturer and supplier of high
More informationALLEN BRADLEY TIMING RELAY
ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY
More information7 Lighting Technology
7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection
More informationSupport Frame STB Technical Instruction Manual
Support Frame STB Technical Instruction Manual Fig. 2.1: Support frame STB 450 Fig. 2.2: Support frame STB 300 Fig. 2.3: Brace bracket SK 150 Product Characteristics The support frames are mainly used
More informationXW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations
Terminal Boxes XWD CSM_XWD_DS_E Simple Wiring of Sensor Actuators Greatly reduce wiring in combination with the Smartclick XS. Insert the connector and turn / of a turn to lock the connectors. Higher rated
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationTeSys circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping
More informationTelemetry Receiver Installation Guide
BBV Telemetry Receiver Installation Guide Models covered Rx200 Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323
More informationES-Mega MegaBeans. Access Control System. User Manual. People in Motion
ES-Mega MegaBeans Access Control System User Manual / Order No. Device People in Motion Contents 1. General description..3 2. Installation Instructions..4 3. Start-up..4 4. Audible signals..4 5. Operating
More informationContactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 16 bits singleturn Process value in 32 bit telegram 3 error bits 16 bits singleturn 15
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More information20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)
OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for
More informationTechnical Information
Reference: For use with LED light engines Geometry (l x w x h): Line voltage, nominal Perm. voltage fluctuations Line current, nominal Inrush current, typical Line frequency Protection Class Output operating
More informationPower Injector 1520 Series
Power Injector 1520 Series Technical Specifications Input voltage 100 to 240 VAC Output voltage 56.0 VDC Voltage range tolerance 54 VDC to 57 VDC Maximum current 1.43 A No load current 15 ma 56VDC@0.71A
More informationRead/write head TN-CK40-H1147
Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated only via BL ident
More informationElectrical connection
Splice sensor Dimensioned drawing en 04-2014/06 50116166-01 4mm 12-30 V DC We reserve the right to make changes DS_IGSU14CSD_en_50116166_01.fm Reliable detection of splice on paper web or plastic web With
More informationMedia Tube HO RGB. 896mm mm mm kg 1.8lbs. 0.4kg 0.9lbs. 1.24kg 2.7lbs. 1.02kg 2.3lbs
Date: Quantity: Company: Project: Media Tube HO RGB Media Tube HO family is a range of versatile media border lighting system for media façade application. It comes with the variety of LED options and
More informationSINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical
More informationcase 5 temperature sensor cosine sensor sine sensor ground + 5V phase 2- phase 2+ phase 1- phase 1+
Motor Cables Accessories Motor Cables Extension cables tailo for use with Norgren NP Linear Motors are available in two different versions; standard and high flex for the use in trailing chains or cable
More informationSQM40/41 Actuators for air and gas dampers
SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The
More informationDFLK-D37 SUB/S. Extract from the online catalog. Order No.:
Extract from the online catalog DFLK-D37 SUB/S Order No.: 2280336 The illustration shows version DFLK-D37 SUB/B VARIOFACE panel feed-through module, for direct coupling of single signal lines of up to
More informationSatellite Dish Installation Manual (Ver. 2) 1
Satellite Dish Installation Manual Provided by DiscoverNet, Inc. Satellite Dish Installation Manual (Ver. 2) 1 Table of Contents Section 1: Introduction Page 3 Section 2: Recommended Tools and Materials
More informationINSTALLATION INSTRUCTIONS FOR. MODEL 2230LED
INSTALLATION INSTRUCTIONS FOR MODEL 2230LED www.sportablescoreboards.com 1 Table of Contents MODEL 2230LED... 3 8 X 4 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:...
More informationINSTALLATION INSTRUCTIONS FOR
INSTALLATION INSTRUCTIONS FOR MODEL 2240LED www.sportablescoreboards.com 1 Table of Contents 8 X 7 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR
More informationSECTION 7 -- CROSS-CONNECT SYSTEMS
DETAIL ENGINEERING REQUIREMENTS AT&T March, 2016 Section 7, ATT-TP-76400 Revised NA SECTION 7 -- CROSS-CONNECT SYSTEMS CONTENTS PAGE 1. GENERAL... 7-2 1.1. Introduction... 7-2 1.2. Cable Holes... 7-2 1.3.
More informationI Ex-protected connectors exlink I
Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity
More informationMedia Tube HO RGBW. High intensity SMT RGB and White LEDs Million additive RGB colors; White CCT 6500K
Date: Quantity: Company: Project: Media Tube HO RGBW Media Tube HO family is a range of versatile media border lighting system for media façade application. It comes with the variety of LED options and
More information