Your First Choice for Control Systems Solutions

Size: px
Start display at page:

Download "Your First Choice for Control Systems Solutions"

Transcription

1 ONTROL SYSTEMS SOLUTIONS FOR PREISION MOTION TEHNOLOGY 135 YEARS OF POSITIONING & PROESS SOLUTIONS Since 1883, Duff-Norton has been at the forefront of precision motion technology. Providing a continued commitment to leading edge manufacturing and highest quality engineered products for the most advanced industrial lifting, positioning and transfer needs for our customers worldwide. Motion technology today is expected to lift, move and precisely position heavy loads, often under extreme or adverse conditions. Whether it s creating motion to twist and pivot, open and close or keeping a production line moving, Duff-Norton has the right solution to meet the demand. Our systems can be found in industries ranging from aluminum, steel, agriculture, pharmaceutical, material handling, energy, food and beverage, and automated machinery. Your First hoice for ontrol Systems Solutions 9415 Pioneer Ave. harlotte, N Phone: (704) (800) Fax: (704) Duffnorton@cmworks.com Duff-Norton ISO 9001: QM Duff-Norton, Inc., olumbus McKinnon Engineered Products. All Rights Reserved. PB-NTL-01 01/18

2 DUFF-NORTON ONTROL SYSTEMS FOR PREISION MOTION TEHNOLOGY DUFF-NORTON ONTROL SYSTEMS TABLE OF ONTENTS Whether you need a custom turn-key solution, a standalone, or an integration into a legacy system our automated motion control solutions bring together the products and technology that improve your processes and move you into the future through each stage of production. DUFF-NORTON ONTROLS Features and Benefits TOM ONTROLS SYNHRONIZATION ONTROLS VARIABLE SPEED ONTROLS POSITIONING ONTROLS PENDANT ONTROLS DIGITAL DISPLAY ONTROLS THREE PHASE JOG ONTROLS SINGLE PHASE JOG ONTROLS OPTIONAL AESSORIES ONTROL OMPARISON HARTS Terms of sale NOTE Duff-Norton has made every effort to ensure that the information contained in the publication is accurate and reliable. Determining the suitability of our products for specific applications is the user s responsibility. WARNING The equipment shown in this catalog is intended for industrial use only and should not be used to lift, support, or otherwise transport people unless you have written statement from Duff-Norton which authorizes the specific actuator used in your applications as suitable for moving people. 2 3

3 DUFF-NORTON ONTROL SYSTEMS Why use Duff Norton ontrols? We are linear motion experts. We know our linear motion products better than anyone and understand the challenges you face navigating a dynamic marketplace that demands innovative technologies and the agility to contend with a greater need for increased productivity. Our industrial experience combined with the latest controls technologies and our broad assortment of linear motion products make us the ideal partner to work closely with you to design and implement your system solutions. Electric control systems support a wide range of applications DUFF-NORTON ONTROL SYSTEMS FEATURES AND BENEFITS Duff-Norton engineers a wide range of controls systems, and can provide turn-key solutions for applications ranging from jogging controls to complex automated systems. We offer systems from fractional horsepower sizes up to 200 HP. STANDARD FEATURES All Duff-Norton controls are designed to meet UL508A NEMA enclosures provided for all applications Labeled terminal strip for ease of field connections Motor overload protection Short circuit protection for all control voltages External Main Disconnect Switch (MDS) All wires labeled for quick troubleshooting Electrical schematics provided for all applications BENEFITS Fewer interfaces Better performance One integrated system Turn-key solutions Reduced downtime Increased productivity INDTRY EXPERTISE Synchronization controls Positioning controls STANDARD HARDWARE PLs HMIs VFDs Safety relays STANDARD SOFTWARE PROGRAMMING PL HMI Variable speed controls Jog ontrols Encoders Motor overloads Linear sensors ontactors VFD SERVO We know how to get the highest performance out of our linear motion products. Through our control solutions we can meet the most advanced industrial lifting, positioning, and transfer demands needed to help you gain a competitive advantage in the global marketplace. 4 5

4 DUFF-NORTON ONTROL SYSTEMS TOM ONTROLS ustom ontrols Duff-Norton realizes no two applications are the same. We work closely with you to understand your application and provide the best possible solution. ontrol packages can be highly customized to meet your needs. We offer a wide variety of options to meet demanding control requirements. Package options can easily be implemented to best fit your application and provide you with complete turn-key solutions. DUFF-NORTON ONTROL SYSTEMS SYNHRONIZATION ONTROLS Synchronization ontrols Synchronization controls provide smooth, reliable synchronization of multiple axis of motion. We offer a variety of solutions for synchronizing from two to six axis of motion. Our synchronization packages are designed with reliability and safety in mind. Most importantly, to hold the tolerances for your specific application. MANUAL SREEN T I/O SREEN Local Message Display MR SAFETY RELAY LIMITS OK DRIVE READY FAULT RAISE 15 HZ RAISE PEDESTAL 2 FORWARD SIDE 40 HZ LOWER 50 HZ LOWER PEDESTAL 2 60 HZ FORWARD SIDE PEDESTAL POSITION RAISE 1 - FORWARD LEFT N.NNN SOUTH SIDE 2 - FORWARD RIGHT N.NNN LOWER 3 - AFT RIGHT N.NNN SOUTH SIDE 4 - AFT LEFT N.NNN RAISE 15 HZ RAISE PEDESTAL 3 40 HZ AFT SIDE LOWER 50 HZ LOWER PEDESTAL 3 60 HZ AFT SIDE RAISE LOWER PEDESTALS PEDESTALS 15 HZ RAISE 40 HZ PEDESTAL 1 50 HZ LOWER 60 HZ PEDESTAL 1 LOAD NNNNN RAISE NORTH SIDE NNNNN NNNNN LOWER NORTH SIDE NNNNN 15 HZ RAISE 40 HZ PEDESTAL 4 50 HZ LOWER 60 HZ PEDESTAL 4 MENU MANUAL SREEN 2 SREEN 2 Local Message Display OUTPUTS O0:0 POWER LIGHT O0:1 MR POWER O0:2 RUN FORWARD O0:3 RUN REVERSE O0:4 SPARE O0:5 DRIVE FREQ 1 O0:6 DRIVE FREQ 2 O0:7 DRIVE ENABLE O0:8 RELEASE BRAKE O0:9 SPARE O0:10 SPARE O0:11 SPARE MAIN MANUAL FAULT INFO INPUTS I0:0 ENODER H A I0:1 ENODER H B I0:2 SPARE I0:3 SPARE I0:4 E-STOP ATIVE I0:5 MR IS ON I0:6 DRIVE READY I0:7 DRIVE FAULT I0:8 SPARE I0:9 SPARE I0:10 SPARE I0:11 SPARE I0:12 BRAKE RELEASED I0:13 SPARE I0:14 SPARE I0:15 SPARE I0:16 SPARE I0:17 SPARE I0:18 EXTEND LIMIT I0:19 RETRAT LIMIT FEATURES & BENEFITS HODS 6 Multiple axis of motion A or D controls Load sensing Servo applications UL, cul Requirements A large majortity of our control panels can be made available with. omplies with U L Additional ustom ontrol Options Stack lights HMI pendants Programming ports Quick disconnects Enclosure heaters Explosion proof enclosures Remote pushbutton stations Motor cables Feedback cables onsole enclosures NEMA type 4/4x enclosures LED indicators Synchronization ontrol Methods Motor starters with motor overload protection Variable Frequency Drives (VFDs) Servo motors with absolute encoders FEEDBAK Synchronization ontrol Feedback Options Incremental encoders Absolute encoders Potentiometers Linear transducers Synchronization ontrol Options Line reactors/filters for longer motor cable lengths 4-12 inch color touch screens (HMI) Pendant controls Live positioning display Strobe/stack light for motion Additional E-Stops omplies with U L 7

5 ONTROL OMPONENTS VARIABLE SPEED ONTROLS ONTROL OMPONENTS POSITIONING ONTROL Variable Speed ontrols Many applications require a variation of speeds during the motion process. Our Variable Speed ontroller allows the speed pot to be adjusted between 0% and 100%, even while the application is in motion. We offer preset, selectable speed controls with a choice of three different speeds (25%, 50% and 100%). If custom speeds are desired, they can be easily entered into a numeric keypad as a percentage ranging from 0 to 100%. You have a choice of a pushbutton controller or color touch screen operator for your application. Positioning ontrol Positioning applications can be complicated and time consuming. We offer an adaptable range of options to precisely position single or multiple axes of motion. Locations can be easily entered with our numeric entry position controls anywhere along a desired axis and then activated with the Move-To pushbutton. Duff-Norton s versatile, programmable entry position control allows up to five preset positions. Positions can be programmed, stored and changed at any time. MANUAL SREEN 1 Standard VFD Synchronization Enclosure Dimensions MR SAFETY RELAY LIMITS OK DRIVE READY Local Message Display FAULT HP HEIGHT WIDTH DEPTH 1/2 3/ /2 42 in 2 30 in 8 in /2 48 in in 10 in URRENT POSITION: NNN.NN INH NNN.NN MM NN.NN NN.NN NN.NN NN.NN NN.NN NN.NN STORE AS STORE AS STORE AS STORE AS STORE AS MOVE SETPOINT 1 SETPOINT 2 SETPOINT 3 SETPOINT 4 SETPOINT 5 POSITION MOVE TO MOVE TO MOVE TO MOVE TO MOVE TO MOVE TO SETPOINT 1 SETPOINT 2 SETPOINT 3 SETPOINT 4 SETPOINT 5 POSITION MANUAL I/O FAULT INFO AUTO STOP BENEFITS FEATURES HODS Variable Speed ontrol Advantages Allows greater flexibility for motion applications Multiple processes can be achieved with the same equipment by adjusting speeds Variable Speed ontrols Options Door mounted Speed Pot adjustable from 0 to 100%. Preset, selectable speeds using a panel mounted selector switch Standard Position ontrol Features Panel mounted emergency stop (E-Stop) Labeled terminal block for field connections enclosure Two-channel safety relay Brake relay, if required Position ontrol Methods Numeric position entry Programmable entry positions Eliminates the need for additional equipment for fast or slow processes Numeric entry speed using a HMI touch screen Fused and shafted Main Disconnect Switch (MDS) Illuminated POWER ON indicator Eliminates equipment hard starts and stops Short circuit protection Prolongs equipment life omplies with U L olor touch screen (HMI) NEMA type 12/13 wall mount omplies with U L 8 9

6 ONTROL OMPONENTS PENDANT ONTROLS Pendant ontrols Duff-Norton pendant controls provide ease of movement around applications. We offer an option of 3, 5, 7, and 9 button pendants. Each pendant control comes standard with an easily accessible emergency stop (E-Stop) button on the pendant. ustomize your pendant with selector switches, momentary pushbuttons, indicators, and nameplates to meet your application need. Pendant controls are available to control packages for jogging, synchronization, positioning, and variable speed uses. ONTROL Digital Display ontrols OMPONENTS DIGITAL DISPLAY ONTROLS Positioning applications are becoming increasingly popular in today s industry. Duff-Norton controls provide easy-to-read, live, positioning feedback and can be used with encoder, linear transducer, or potentiometer feedback. Scaling a linear application is easy using the panel mounted pushbuttons on the digital display. Display Resolution inches Digital Display ontrols Features Input Types Potentiometer (0-10K OHM) Encoder Analog 4-20 Ma Power A and D models available FEATURES BENEFITS Standard Pendant ontrol Features Three, five, seven, and nine button pendants Emergency Stop (E-Stop) on pendant ustom Pendant ontrol Features Selector switches Momentary pushbuttons Indicators ustom nameplates Additional Pendant ontrol Options LOAL/REMOTE keyed switch Illuminated E-Stop ustomizable pendant cable lengths omplies with U L Standard Benefits of Digital Display ontrols Digital display controls can easily be zeroed with the press of a single button Digital display controls offer live feedback for precise positioning Displays can be set up to display up to five decimal positions No need for excitation power supplies for potentiometer applications Additional pull-up resistors are not required for encoder applications Digital Display ontrols Options Multiple displays can be used in the same control panel Optional outputs for indicators or alarms Displays can be provided for existing applications omplies with U L Three Button ontrol Pendant Five Button ontrol Pendant Nine Button ontrol Pendant 10 11

7 ONTROL OMPONENTS THREE PHASE JOG ONTROL ONTROL OMPONENTS SINGLE PHASE JOG ONTROL Three Phase Jog ontrol Duff-Norton standard three phase jogging motor controls provide simple operation and reliable service. To start motion simply press and hold the extend or retract pushbutton. To stop motion release either the extend or retract pushbutton. Our three phase jogging motor controls come standard with a power on indicator to inform users that the panel is under power. Standard three phase jog panels include an auxiliary brake relay if fast stopping is required. Labeled terminal strips are included for easy termination of end-of-travel limit switches. Single Phase Jog ontrol Duff-Norton offers single phase jogging control panels that meet a wide variety of single phase voltages. All of our control panels come standard with short circuit protection devices as well as adjustable motor overload protection. Three Phase Jog ontrols Specifications Single Phase Jog ontrols Specifications Motor Sizes Voltage Enclosure Dimensions Enclosure Mounting Motor Sizes Voltage Enclosure Dimensions Enclosure Mounting Up to 10 HP 460 VA/3 PH/60 Hz 20"H x 16"W x 6"D Wall Mount Up to 1.5 HP 110/115/120 VA/1 PH/ 50/60 Hz 220/230/240 VA/1 PH/ 50/60 Hz 16"H x 14"W x 6"D Wall Mount FEATURES FEATURES Standard Features for all ontrol Boxes Twist-to-release, Illuminated LED EMERGENY STOP button Labeled terminal block for field connections Fused and shafted Main Disconnect Switch (MDS) Fused 120VA transformer for control voltage NEMA type 12/13 wall mount enclosure Interlocked reversing contactor Adjustable motor overload Brake relay provided for fast braking applications Additional Feature Options Illuminated EXTEND/RETRAT pushbuttons MOTOR OVERLOAD indicator Pendant controls Strobe/stack light alarm Maintained operations 230/575V available omplies with U L Standard Features for all ontrol Boxes Twist-to-release Illuminated LED EMERGENY STOP button Labeled terminal block for field connections Door mounted Main Disconnect Switch (MDS) NEMA type 12/13 wall mount enclosure Electrical/mechanical interlocked motor starters Adjustable motor overload Illuminated POWER ON indicator Momentary EXTEND/RETRAT pushbuttons Additional Feature Options Shafted Interlocked MDS Illuminated EXTEND/RETRAT pushbuttons MOTOR OVERLOAD indicator Pendant controls Strobe/stack light alarm Maintained operation omplies with U L Illuminated POWER ON indicator Momentary EXTEND/RETRAT pushbuttons 12 13

8 14 ONTROL OMPONENTS OPTIONAL AESSORIES & OMPARISON HARTS Optional ontrols Accessories At Duff-Norton our goal is to provide high quality, reliable control solutions that get your application up and running fast. Our optional accessories include the following: motor cables, VFD cables, sensor cables and cord grips. With minimal time and effort, you ll have all the parts you need to install your new control system. OPTIONAL AESSORIES ontrol Accessory Options Encoder cables Limit switch cable Potentiometer cable VFD cable Motor cable Linear transducer cable ord Grips Strain reliefs Switches - mechanical/ electrical omparison harts Accuracy Potentiometer 0.60 Positioning Device Accuracy Encoder Servo Linear Sensor Device Encoder able Strain Relief Encoder cables are available in four standard lengths 4, 10, 15, and 20 meters. Ask about custom lengths. Positioning / Synchronization Accuracy By ontrol Type and Feedback Device Blue ord Grip Black Brown White Jogging Jogging motion is the simplest and most common type of motion. Jogging an electric motor can be accomplished in two ways, 0.40 momentary or maintained. Momentary jogging dictates continual input from a user. The user must press and hold a pushbutton to jog the motor in one direction or the other. Maintained jogging is accomplished through a one-time command such as pressing and releasing a pushbutton. Momentary jogging stops when the user releases a pushbutton. Maintained jogging stops when the user presses the stop 0.25 pushbutton or the motor reaches a limit switch Positioning Positioning applications move an electric motor to a specific position. Positioning can be accomplished using an A, D, or servo motor along with a feedback device. Servo motors and certain A and D motors have encoders mounted on the motor. These devices run in a closed loop to accurately move the electric motor to a desired position. Positioning devices typically use a HMI and input from a user to 0.10 position the electric motor Synchronization Synchronization motion allows two or more electric motors to be moved in the same direction together. Synchronization motion Servo - Servo - VFD - VFD - VFD - ontactors - ontactors - ontactors - is most useful in applications that cannot be mechanically coupled. Synchronization provides a means to electrically couple the electric Linear Absolute Linear Encoder Potentiometer Linear Sensor Encoder Potentiometer motors. Synchronization uses positional feedback from multiple motors to hold a tolerance between the motors. Synchronization motion uses Transducer Encoder Transducer multiple types of feedback as well as motor control devices. ontrol Type - Feedback Device Variable Speed Variable speed motion allows an electric motor to be moved at various speeds. Variable speed applications are common in Note: Accuracy is dependent on speed and type of actuator. The above chart is a general guideline for accuracy. applications where the manufacturing process changes frequently. Variable speed applications are useful in applications where the motor needs to start slowly and ramp up to speed. HMIs, speed pots, and selector switches can be used to vary the speed of an electric motor. HMIs provide the most flexibility by allowing the user to Ph: input (800) a desired speed. Fax: (704) Accuracy (Inch) Flexibility Variable Speed Device Flexibility Selector Switch Speed Pot HMI Entry Variable Speed Device Accuracy Synchronization Device Accuracy Motor ontactors VFDs Servo Motors Motor ontrol Device Glossary HMI Human Machine Interface. Typically a 4 10 inch color touch screen used as a central point for system input. HMIs reduce the need for multiple pushbuttons, indicators, and selector switches. HMIs are extremely versatile and completely customizable. HMIs relay information about a systems I/O, status, status of switches and sensors, as well as specific fault messages. HMIs reduce setup time, troubleshooting, maintenance, and down time. VFD Variable Frequency Drives. VFDs or inverters are used to vary the speed of an electric A or D motor. VFDs can use single phase or three phase A input voltage to drive three phase A motors. VFDs are extremely beneficial in applications where synchronization, positioning, or variable speed is required. VFDs can be programmed to ramp up, accelerate, or ramp damp, decelerate, over a specific period of time. PL Programmable Logic ontroller. PLs are controllers that utilize microprocessors to make quick calculations and control peripheral devices. PLs are often used to read analog inputs as well as encoder inputs. PLs are flexible and easily allow for process changes as well as equipment upgrades. MDS Main Disconnect Switch. MDSs are used to turn the facility service to a control panel on and off. MDSs can be locked out and tagged out to keep personnel safe while maintenance is being performed. E-Stop Emergency Stop. E-Stops are typically an illuminated or non-illuminated pushbutton used to stop equipment in the case of an emergency. E-Stops are hardwired to disconnect power to an electric motor(s) as well as de-energize control relays. Terminal Strip Terminal strips consist of several individual terminal blocks aligned in a row. Terminal blocks pass wires from one point in a control panel to another point. Terminal blocks are extremely advantageous when wiring field installed devices such as encoders, motors, and switches. Terminal blocks allow wiring of these devices to be terminated at the terminal block as opposed to being terminated at a PL, VFD, or motor contactor. Panel Meter Panel meters are used to display feedback from a number of input devices. Panel meters are digital displays that provide visual indication of a devices current position. Panel meters use input from potentiometers, linear sensors, encoders, or other analog devices. The signals are then scaled using the panel meter to display position in a meaningful value such as inches or percentage. Types of feedback Incremental encoders Incremental encoders provide digital pulses or counts back to a PL or VFD. A PL can be programmed to use encoder pulses to synchronize, position, or vary the speed of an electric motor. Incremental encoders can be mounted on limit switches, reducers, or electric motors. Incremental encoders offer a variety of different pulses per revolution (PPR). Incremental encoders can provide as little one pulse per revolution up to several thousand pulses per revolution. Absolute encoders Absolute encoders work similarly to incremental encoders. Pulses or counts are monitored by a PL or VFD. Ethernet/IP encoders communicate with a PL over an Ethernet cable. Unlike incremental encoders, absolute encoders do not lose position or counts when power is cycled. There is no need to reference or home absolute encoders after a power cycle. Potentiometers Potentiometers provide a 0 10 VD analog output signal. This analog signal can be used by a PL to scale the position of a device. Potentiometer feedback can be found in rotary or string type devices. Rotary potentiometers can be mounted on limit switches. String type potentiometers are usually mounted to equipment. Potentiometers are useful when an extremely precise degree of accuracy is not needed. Linear Sensors Linear sensors output a 0 10 VD, or 4 20mA analog output signal. Like a potentiometer this analog signal can be used by a PL to scale and position or control an electric motor. Depending on the location of the linear sensor in an application, linear sensors provide the highest degree of accuracy. Linear sensors come in a variety of configurations. Rod, magnetic, and non-contact sensors are most frequently used. Load ells Load cells are feedback devices that detect load. Load cells can detect load in tension, compression, or both tension and compression. Load cells are ideal for applications where load detection or load processes are needed. Load cells like linear sensors come in a variety of configurations such as pancake, donut, or pin style. Types of motion 15

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

Single Axis Position Controller

Single Axis Position Controller SERIES P9511 Single Axis Position Controller Compact Construction Simple Go-to operation Integrated Relay Output Integrated Mains Power Supply ELEKTRO-TRADING sp. Z o.o. 44-109 Gliwice, ul. Mechaników

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information

Label Applicator HERMA 400

Label Applicator HERMA 400 Label Applicator HERMA 400 Info GB V6.0 / 30.3.07 [ Facts & Data ] R Constructional variant Right-hand or left-hand version, always flexible to use L Power supply / Line voltage Max. power consumption

More information

PSC300 Operation Manual

PSC300 Operation Manual PSC300 Operation Manual Version 9.10 General information Prior to any attempt to operate this Columbia PSC 300, operator should read and understand the complete operation of the cubing system. It is very

More information

Revision 1.2d

Revision 1.2d Specifications subject to change without notice 0 of 16 Universal Encoder Checker Universal Encoder Checker...1 Description...2 Components...2 Encoder Checker and Adapter Connections...2 Warning: High

More information

MICROMASTER Encoder Module

MICROMASTER Encoder Module MICROMASTER Encoder Module Operating Instructions Issue 01/02 User Documentation Foreword Issue 01/02 1 Foreword Qualified Personnel For the purpose of this Instruction Manual and product labels, a Qualified

More information

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder

More information

Understanding VFD. Variable Frequency Drive. nfi. nfi

Understanding VFD. Variable Frequency Drive. nfi. nfi Understanding VFD Variable Frequency Drive Practical Demonstration of VFD Delta- M Series 1.5 KW I/P: 230V 1/3 Phase O/P: 230 3 Phase VFD Status Screen Motor OFF Command Freq. Parameters Direction Amperes

More information

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO Model 207 Automatic GTAW Welding System 1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small

More information

Condition Monitoring Custom Products

Condition Monitoring Custom Products Features: CMCP500 Series Transmitters World s Most Popular HMI Machine Mimics Historical and Real Time Trending Current and Historical Alarm Lists Standard MODBUS A to D Converter Other Protocols Optional

More information

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!

More information

(Catalog No HSCE) Product Data

(Catalog No HSCE) Product Data (Catalog No. 1746-HSCE) Product Data The High-Speed Counter Module, Catalog Number 1746-HSCE, is used in control applications where the ability to detect high-speed machine or process motion is critical.

More information

Multi-functional safety relay modules PROTECT SRB-E

Multi-functional safety relay modules PROTECT SRB-E Multi-functional safety relay modules PROTECT SRB-E PROTECT SRB-E The configurable User-friendly Up to 16 different applications can be selected Monitoring of all conventional safety switchgear Safety

More information

ROTARY ENCODER SELECTION. A Step by Step Guide

ROTARY ENCODER SELECTION. A Step by Step Guide ROTARY ENCODER SELECTION A Step by Step Guide ENCODER SELECTION (THE BASICS) Choosing the right encoder may seem overwhelming. There are so many options and configurations that you may or may not require

More information

Basic, cost-effective motor control in one unit: MOVITRAC 07.

Basic, cost-effective motor control in one unit: MOVITRAC 07. Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services Basic, cost-effective motor control in one unit: MOVITRAC 07. Frequency inverter 2 Basic, cost-effective motor control

More information

AF-300 E11 Adjustable Frequency Drive

AF-300 E11 Adjustable Frequency Drive AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed

More information

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Operating Instructions for Throttle Valves Using VRC Valve Positioner ThrottleMaster TM Operating Instructions for Throttle Valves Using VRC Valve Positioner p/n: X709116 $10.00 3/2012 Throttlemaster is a registered trademark of Vacuum Research Corporation Introduction The

More information

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz. HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with

More information

ADJUSTABLE SPEED DRIVES. nc1 Drive

ADJUSTABLE SPEED DRIVES. nc1 Drive ADJUSTABLE SPEED DRIVES nc1 Drive Ultra-Compact Sub-Micro Drive The nc1 is a sub-micro, or nano-sized drive with a full range of features to meet the needs of nearly any user. The nc1 is designed to be

More information

Digital Ratio Controller

Digital Ratio Controller Digital Ratio Controller RSC-406 Control Panel USER S MANUAL RATIO CONTROLLER SPEED RUN PRG ERR RATIO % CH RSC-406 Prelude Thank you for applying our RSC-406 Ratio Controller (abb.406) to you machinery

More information

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1100, SM-1500 and SM-1600 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating

More information

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive nfi Practical Demonstration of VFD Motor Speed Directly Proportional to Frequency Motor RPM= (120*F)/P Powerflex- 4M 0.4 KW= 0.5 Hp

More information

Frequency Converter EFC 3610, EFC 5610

Frequency Converter EFC 3610, EFC 5610 Frequency Converter EFC 3610, EFC 5610 2 EFC 3610, EFC 5610 frequency converter Using valuable energy responsibly Using valuable energy responsibly Rising energy costs and increasing demands for environmentally-friendly

More information

Sentinel I24 Digital Input and Output Configuration

Sentinel I24 Digital Input and Output Configuration Application Bulletin: #155 Date: October 19, 2007 Sentinel I24 Digital Input and Output Configuration The Sentinel I24 can communicate with external hardware using digital inputs and outputs. There are

More information

SPECIFICATION NO NOTE

SPECIFICATION NO NOTE NOTE The Model 207-1 is a special version of the standard M-207 Power Supply. It has been altered for a special applications requiring low current operation at high arc voltages in ambient and pressurized

More information

MTL Software. Overview

MTL Software. Overview MTL Software Overview MTL Windows Control software requires a 2350 controller and together - offer a highly integrated solution to the needs of mechanical tensile, compression and fatigue testing. MTL

More information

SC26 Magnetic Field Cancelling System

SC26 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields

More information

Frequency Converter EFC 3610, EFC 5610

Frequency Converter EFC 3610, EFC 5610 Frequency Converter EFC 3610, EFC 5610 2 EFC 3610, EFC 5610 frequency converter Using valuable energy responsibly Using valuable energy responsibly Rising energy costs and increasing demands for environmentally-friendly

More information

SECTION COMMERCIAL DOOR OPERATORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION COMMERCIAL DOOR OPERATORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08 71 13 COMMERCIAL DOOR OPERATORS Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2010-2010 ARCAT, Inc. - All rights reserved ** NOTE TO SPECIFIER ** Overhead Door Corporation;

More information

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442) BOSTON GEAR CONTROLLERS ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers ACE 10 Series Noted for exceptionally low motor noise, high starting torque and cool operation in a compact

More information

Bulletin 150, 154 Softstarters Quick Selection Table

Bulletin 150, 154 Softstarters Quick Selection Table Bulletin 50, 54 Quick Selection Table Type Current Range Bulletin No. 50 50 50 SMC-3 Controller 85 A SMC-Delta Controller 47 A SMC Flex Controller 54 480 A Soft Start Kickstart Current Limit Dual Ramp

More information

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: ICAO: IEC: 61822 CENELEC: AC 150/5345-10 (current edition), L-828, L-829. Aerodrome Design Manual Part 5, para. 3.2 (current

More information

AUTOMATING YOUR SUCCESS

AUTOMATING YOUR SUCCESS AUTOMATING YOUR SUCCESS OUR HISTORY The latest edition to the Absolute Group of Companies, Absolute Robot, was founded on the same customer focused mindset that has allowed Absolute Machinery and Absolute

More information

SRV02-Series. Rotary Pendulum. User Manual

SRV02-Series. Rotary Pendulum. User Manual SRV02-Series Rotary Pendulum User Manual Table of Contents 1. Description...3 2. Purchase Options...3 2.1 Modular Options...4 3. System Nomenclature and Components...5 4. System Configuration and Assembly...6

More information

VAT 20 Adjustable Frequency Drive

VAT 20 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive The VAT 0 is a small, flexible, low cost, well performing AC drive designed for use in small machines such as fans and conveyors. The drive

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets MicroSafe MCF4700 C US File No. LR90200 MicroSafe Flexible MCF4700-12, MCF4700-20, MCF4700-30 12 mm, 20 mm and 30 mm resolution versions Compact segmented light curtain 1.02 inch (26 mm) x 1.1 inch (28

More information

The CIP Motion Peer Connection for Real-Time Machine to Machine Control

The CIP Motion Peer Connection for Real-Time Machine to Machine Control The CIP Motion Connection for Real-Time Machine to Machine Mark Chaffee Senior Principal Engineer Motion Architecture Rockwell Automation Steve Zuponcic Technology Manager Rockwell Automation Presented

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Nidec Industrial Solutions Applying Encoders in Mining

Nidec Industrial Solutions Applying Encoders in Mining Nidec Industrial Solutions Applying Encoders in Mining Nidec Industrial Solutions EXTREME MACHINES THROUGHOUT THE WORLD Mining Marine Metals Cranes Energy: Wind, Oil, & Gas Forest Products Introduction

More information

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders Scott Hewitt, President SICK STEGMANN, INC. Dayton, OH www.stegmann.com sales@stegmann.com 800-811-9110 The

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

Rotary Knife Controller

Rotary Knife Controller PCM-22 Rotary Knife Controller Information furnished by EMERSON Motion Control is believed to be accurate and reliable. However, no responsibility is assumed by EMERSON Motion Control for its use. EMERSON

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

Simple motion control implementation

Simple motion control implementation Simple motion control implementation with Omron PLC SCOPE In todays challenging economical environment and highly competitive global market, manufacturers need to get the most of their automation equipment

More information

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

Ecoline S series. Precision solutions for quality production. Innovations for a better world. Ecoline S series. Precision solutions for quality production. Innovations for a better world. Precision solutions for quality production. Die casting with confidence. The Ecoline S is a series of cold-chamber

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

Micro-DCI 53ML5100 Manual Loader

Micro-DCI 53ML5100 Manual Loader Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with

More information

Session 1 Introduction to Data Acquisition and Real-Time Control

Session 1 Introduction to Data Acquisition and Real-Time Control EE-371 CONTROL SYSTEMS LABORATORY Session 1 Introduction to Data Acquisition and Real-Time Control Purpose The objectives of this session are To gain familiarity with the MultiQ3 board and WinCon software.

More information

GENMARK Engineering & Management # Street Edmonton, AB T5S 1R5 CANADA Phone (780) Fax (780)

GENMARK Engineering & Management # Street Edmonton, AB T5S 1R5 CANADA Phone (780) Fax (780) GENMARK Engineering & Management #200 10459-178 Street Edmonton, AB T5S 1R5 CANADA Phone (780) 461-9234 Fax (780) 461-9624 GENMARK Engineering & Management Contract engineering and management services

More information

Function Manual SIMATIC HMI TP900. Operator Panel.

Function Manual SIMATIC HMI TP900. Operator Panel. Function Manual SIMATIC HMI TP900 Operator Panel Edition 10/2016 www.siemens.com Introduction 1 Safety notes 2 Medium-voltage converters SIMATIC Description 3 Screens 4 Installing software 5 Function

More information

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap Description: The TR5000 is a Full Logic Control Process ratemeter that can display up to three separate values of rate and compare them to programmable set points. Rates A & B can be programmed by the

More information

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications. MIRAL The Admiral Type family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications. Its features include: Extremely easy connection and

More information

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & & Exercise 4-2 EXERCISE OBJECTIVE To describe the operation of an electrical counter; To assemble and test a continuous reciprocation system; To extend and retract a cylinder a definite number of times using

More information

R-1580A Microwave Downconverter. Product Brochure

R-1580A Microwave Downconverter. Product Brochure R-1580A Microwave Downconverter Product Brochure Jan 2018 Highlights The DSII Model R-1580A Microwave Downconverter extends the coverage of the R-1550A, or other DSII wide range receivers, to 22 GHz. The

More information

GP-500 SERIES - Low Voltage

GP-500 SERIES - Low Voltage M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

Designing Intelligence into Commutation Encoders

Designing Intelligence into Commutation Encoders I Designing Intelligence into Commutation Encoders By: Jeff Smoot, CUI Inc C U I NC Encoder users traditionally have been reluctant to change with good reason. Motor control on the factory floor or in

More information

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5. EF User Guide UD51 Second encoder small option module for Unidrive Part Number: 0460-0084-05 Issue Number: 5 www.controltechniques.com Safety Information The option card and its associated drive are intended

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

icontrol Integrated Control System Operator s Card

icontrol Integrated Control System Operator s Card icontrol Integrated Control System Operator s Card WARNING: Allow only qualified personnel to operate this equipment. Follow the safety instructions in this document and all other related documentation.

More information

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 LINEAR ACTUATORS Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for

More information

Auxiliary states devices

Auxiliary states devices 22 Auxiliary states devices When sampling using multiple frame states, Signal can control external devices such as stimulators in addition to switching the 1401 outputs. This is achieved by using auxiliary

More information

Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide BBV Telemetry Receiver Installation Guide Models covered Rx400P Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323

More information

PT9150. Heavy Industrial Incremental Encoder

PT9150. Heavy Industrial Incremental Encoder PT950 Heavy Industrial Incremental Encoder Linear Position to 550 inches (00 cm) luminum or Stainless Steel Enclosure Options VLS Option To Prevent Free-Release Damage IP67 NEM 6 Protection GENERL Full

More information

Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide BBV Telemetry Receiver Installation Guide Models covered Rx200 Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323

More information

General Specifications

General Specifications General Specifications WG41F11C Compact O Frame GS 14M04B10-20E-Z1 [Style: S1] Overview The WG41F11C Compact O frame is a space-saving frame designed for coating lines of battery electrode sheets. This

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5) Operator Manual Transfer Switch 40-1000 Amperes OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) English Original Instructions 10-2015 962-0131 (Issue 5) Table of Contents 1. SAFETY PRECAUTIONS...

More information

APQ Series Type C Power Factor Correction Banks

APQ Series Type C Power Factor Correction Banks APQ Series Type C Power Factor Correction Banks N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Regardless of the load size or type, APQ will work

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information

Quick-disconnect cables. Adjustable mounting brackets

Quick-disconnect cables. Adjustable mounting brackets MiniSafe File No. LR90200 Operation MiniSafe 1.0 inch (25.4 mm) resolution 100 foot (30.5 m) range Individual Beam Indicator lights covered by U.S. and international patents Compact size 2.25 x 1.8 inches

More information

Topic: Instructional David G. Thomas December 23, 2015

Topic: Instructional David G. Thomas December 23, 2015 Procedure to Setup a 3ɸ Linear Motor This is a guide to configure a 3ɸ linear motor using either analog or digital encoder feedback with an Elmo Gold Line drive. Topic: Instructional David G. Thomas December

More information

MAXIMUM PRODUCTIVITY DUE TO SHORTEST CONVERSION TIMES

MAXIMUM PRODUCTIVITY DUE TO SHORTEST CONVERSION TIMES EN crimp module MAXIMUM PRODUCTIVITY DUE TO SHORTEST CONVERSION TIMES The C1370 and C1340 crimp modules guarantee the shortest changeover times on the latest fully automatic wire processing machines from

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

DX-10 tm Digital Interface User s Guide

DX-10 tm Digital Interface User s Guide DX-10 tm Digital Interface User s Guide GPIO Communications Revision B Copyright Component Engineering, All Rights Reserved Table of Contents Foreword... 2 Introduction... 3 What s in the Box... 3 What

More information

M Traverse User Manual Revision F

M Traverse User Manual Revision F M Traverse User Manual 0001-0122 Revision F i Technical Assistance If you have comments or questions concerning the operation of the M Traverse, a member of our Technical Support Staff will be happy to

More information

DM1624, DM1612, DM812

DM1624, DM1612, DM812 Installation Guide Hardware and Software DM Series Digital Processors models DM1624, DM1612, DM812 LECTROSONICS, INC. 1 Installation Specific Information Only This guide covers only installation related

More information

Frequency Converter EFC 3610, EFC 5610

Frequency Converter EFC 3610, EFC 5610 Frequency Converter EFC 3610, EFC 5610 2 EFC 3610, EFC 5610 frequency converter Using valuable energy responsibly Using valuable energy responsibly Rising energy costs and increasing demands for environmentally-friendly

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

51109 Köln St. Asaph, Denbigshire LL17OLJ

51109 Köln St. Asaph, Denbigshire LL17OLJ Commissioning the Digital Shaft Copier (DSC) Kollmorgen Steuerungstechnik KOLLMORGEN LIFT CONTROLS Broichstraße 32 Unit 17, St. Asaph Business Park 51109 Köln St. Asaph, Denbigshire LL17OLJ Telefon +49

More information

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL INTRODUCTION The Gemini 5200 is another unit in a multi-purpose series of industrial control products that are field-programmable to solve multiple

More information

Dancer control slims down while gaining functionality

Dancer control slims down while gaining functionality Dancer control slims down while gaining functionality Delta Servo drives with onboard control plus integrated HMI eliminate the need for a PLC on a film handling module. When Company X decided to build

More information

April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION

April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION World-Class Detection Anritsu's Side View applies the XR75's renowned detection to rigid and tall products. Anritsu HD imaging technology is now available

More information

Section C Recorders. DPR mm Digital Strip Chart Recorder

Section C Recorders. DPR mm Digital Strip Chart Recorder 91-00-01-01 Section C Recorders Contents Product Type Literature No. Overview 40-00-02-02 LeaderLine PC Software 51-52-03-16 SCF Software Configuration Tool 51-52-03-26 SDA Software Data Analysis Tool

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

SAPLING WIRED SYSTEM

SAPLING WIRED SYSTEM SAPLING WIRED SYSTEM Sapling 2-Wire System DESCRIPTION The Sapling 2-Wire System is one of the most innovative and advanced wired systems in the synchronized time industry. It starts with the SMA Series

More information

Power Performance Drill Upgrades. TorqReg. ARDVARC Advanced Rotary Drill Vector Automated Radio Control. Digital Drives Upgrade

Power Performance Drill Upgrades. TorqReg. ARDVARC Advanced Rotary Drill Vector Automated Radio Control. Digital Drives Upgrade TorqReg Digital Drives Upgrade ARDVARC Advanced Rotary Drill Vector Automated Radio Control ARDVARC CONCEPT 1. Create an Automated drill system that would allow the mine operator to train new personnel

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

PT8420 Cable Actuated Sensor Industrial ma 0..20mA PT8 Cable ctuated Sensor Industrial.. m..m bsolute Linear Position to 6 inches (5 mm) luminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 / NEM 6 Hazardous rea Certification

More information

A Full Line of Robots for Injection Molding: YS and ST Series Sprue Pickers SB Series Servo Robots SC Series Heavy Duty Servo robots

A Full Line of Robots for Injection Molding: YS and ST Series Sprue Pickers SB Series Servo Robots SC Series Heavy Duty Servo robots Machinery Center Inc. Presents A Full Line of Robots for Injection Molding: YS and ST Series Sprue Pickers SB Series Servo Robots SC Series Heavy Duty Servo robots APEX DYNAMICS, INC. A worldwide leading

More information

Pulse Generator for the Industry. Transit Time Sensors from wenglor

Pulse Generator for the Industry. Transit Time Sensors from wenglor Pulse Generator for the Industry Transit Time Sensors from wenglor Pioneering in the Field of Optical Sensor Technology WinTec: wenglor Innovation As an internationally established technology leader for

More information

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering USER GUIDE DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version 1.35 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487 www.dmengineering.com Overview:

More information

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4. DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER For the DAAB EP104 automatic control system with software version 4.07 Revision: 12 FAAC Nordic AB BOX 125, SE-284 22 PERSTORP SWEDEN, +46

More information