TeSys GV2 and GV3 Manual Starter and Protector
|
|
- Blaze Taylor
- 6 years ago
- Views:
Transcription
1 GV2ME GV2P2 with GV2GH7 installed Starters TeSys GV2 and GV3 Manual Starter and Protetor Refer to 2520CT000 The GV family of produts are 3-pole, horsepower rated, UL 508 listed, manual starters. They inlude a manual disonnet, lass 0 ambient-ompensated thermal overload relay, and an instantaneous magneti trip mehanism in one ompat unit. Any GV manual starter an be used alone for loal manual ontrol of a motor with individual full-load urrents up to 220 amps. The GV family of produts may also be used in group motor installations in aordane with National Eletri Code artile Group motor installations give you greater panel density for smaller size and require fewer parts and less wiring neessary for installation when ompared to onventional panel designs. The GV2P and GV3P produts also have an additional UL 508 type E rating as a stand alone self-proteted manual ombination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P or part number GV3G66 for the GV3P. The GV2P and the GV3P self-proteted manual ombination starter may also be ombined with speifi size ontators from the LCD produt family for a UL 508 Type F ombination starter onstrution. These produts have UL-listed short iruit urrent rating from 0 00 KA depending on appliation size and voltage. See for more information. How to Order To order the basi motor starter, selet the model number (GV2ME, GV2P, or GV3P ) with the appropriate thermal setting from the table below. The thermal trip range and setting should be determined from the motor nameplate fullload urrent. Table 8.24: Thermal Setting (A) 5 V Maximum Horsepower Ratings Ø 3Ø 230 V 200 V 230 V 460 V 575 V Group Motor Appliations Max. Fuse or Ciruit Breaker GV2/3M push button GV2/3P rotary handle A GV2ME0a 59. GV2P A GV2ME02a 59. GV2P A GV2ME03a 59. GV2P A GV2ME04a 80. GV2P A GV2ME05a 80. GV2P A GV2ME06a 80. GV2P A GV2ME07a 80. GV2P / A GV2ME08a 80. GV2P / A GV2ME0a 80. GV2P A GV2ME4a 80. GV2P A GV2ME6a 224. GV2P A GV2ME20a 224. GV2P A GV2ME2a 224. GV2P A GV2ME22a 224. GV2P A GV2ME GV2P GV3P New! GV3P GV3P GV3P GV3P GV3P GV3P a For spring terminals add 3 to the atalog number, for example, GV2ME03. GV2ME32 is not available with spring terminals. 8 STARTERS GV3P GV7RE20 Table 8.25: Thermal Setting (A) 5 V Maximum Horsepower Ratings Ø 3Ø Toggle Operator 230 V 200 V 230 V 460 V 575 V Standard Interrupt High Interrupt Speifiations page 8-36 Aessories pages 8-34 to 8- Dimensions pages 8-52 to GV7RE GV7RS GV7RE GV7RS GV7RE GV7RS GV7RE GV7RS GV7RE GV7RS GV7RE00 6. GV7RS GV7RE GV7RS GV7RE GV7RS E64864 CCN NLRV LR8630 Class Shneider Eletri I Disount 8-33
2 8 STARTERS Starters Aessories GVAU6 GVAE GVAD00 Table 8.26: Voltage Trips a Voltage trips GV2 & GV3P TeSys GV2 and GV3 Manual Starters and Protetors Undervoltage or Shunt trip (external mount, blok right side only) Refer to 2502CT000 Only one trip or fault signaling ontat an be installed per GV2/GV3 devie. Desription Charateristis Voltage Frequeny a 24 V 50 Hz 60 Hz GVA 025 GVA V 50 Hz 60 Hz GVA 055 GVA V 50/60 Hz GVA V 50 Hz GVA 5 60 Hz GVA V 50 Hz GVA V 60 Hz GVA V 50 Hz GVA V 60 Hz GVA V 50 Hz 60 Hz GVA 225 GVA V 50 Hz GVA Hz GVA V 50 Hz GVA V 60 Hz GVA V 60 Hz GVA V 60 Hz GVA V 50 Hz 600 V 60 Hz GVA 505 To order an under voltage trip: replae the bullet ( ) with a U, example: GVAU025. To order a shunt trip: replae the bullet ( ) with an S, example: GVAS025. Table 8.27: Auxiliary Contat Bloks Desription Instantaneous auxiliary ontats GV2 + GV3P Fault signaling ontat + instantaneous auxiliary ontat GV2 + GV3P Mounting Loation Max. No. of Bloks Frontbg Left Hand Side 2 Left Hand Sided Contat Type Sold in lots of N.O. or N.C. GVAE 2.80 N.O. + N.C. 0 GVAEe.70 N.O. + N.O. GVAE20e.70 N.O. + N.C. GVANe.70 N.O. + N.O. GVAN20e.70 N.O. (fault) + N.O. GVAD00.00 N.O. (fault) + N.C. GVAD00.00 N.C. (fault) + N.O. GVAD00.00 N.C. (fault) + N.C. GVAD00.00 Short iruit signaling ontat GV2 + GV3P Left Hand Side SPDT GVAM.70 b Mounting of a GVAE ontat blok or a GV2AK00 visible isolation blok on GV2P. Choie of N.C. or N.O. ontat operation, depending on whih way the reversible blok is mounted. d The GVAD is always mounted next to the starter. e For spring terminals add 3 to the atalog number. Example: GVAE3 f One trip or one fault signaling an be fitted per GV3. g Cannot be used with GV2GH7 insulator. Table 8.28: Voltage Trips Tehnial Data (GV2AU, GV2AS) h Rated Voltage 660 Va Model Inrush Sealed Pik-Up Voltage Drop-Out Voltage Operating Timeh GVAU 2 VA / 8 W 3.5 VA /. W 0.8 to. 0. to to 5 ms GVAS 4 VA / 0.5 W 5 VA /.6 W 0.7 to. 0.2 to to 5 ms From the loss of voltage at the trip terminals to the opening of the starter ontats. Table 8.29: GV3P Aessories New! Desription For GV3P Set of 3-pole 5 A busbars (tap-offs: 2, pith: 64 mm) GV3P GV3G Set of 3-pole 5 A busbars (tap-offs: 3, pith: 64 mm) GV3P GV3G Cover Larger Spaing UL 508 type E (Only one over required on supply side) GV3P GV3G IP 20 over (Two overs required per starter) GV3P LAD Padloking devie For use with up to 4 padloks (not supplied) GV3P GV3P Ø 6 mm shank maximum GV2V GVAN Shneider Eletri CP0 I Disount
3 8 STARTERS Starters Aessories LSD30 TeSys Manual Starters and Protetors LS Fuseholders mm wide (same dimensions as GV2ME) Available with srew lamp and spring type terminals Mounts diretly to LCD09 D32 ontators (with use of GV2AF3 or GV2AF4) Meets appliation needs for fusible starter Uses GV2AE instantaneous ontat bloks to open ontrol iruits DIN rail mounted Refer to 2502CT000 Table 8.33: Dimensions Desription Fuse Type IN mm Use In Spring terminals, 3-pole CC, KTK-R 0.4 x x 38 US Markets LSD Srew lamp terminals, 3-pole CC, KTK-R 0.4 x x 38 US Markets LSD Spring terminals, 3-pole am, gg 0.39 x.5 0 x 38 European Markets LSD Srew lamp terminals, 3-pole am, gg 0.39 x.5 0 x 38 European Markets LSD Auxiliary main pole adder am, gg 0.39 x.5 0 x 38 European Markets LA8D324a 65. a Can be mounted on left-hand or right-hand side of the 3-pole LSD32 blok. Table 8.34: Speifiations Type LSD30, LSD303 LSD32, LSD323, LSDT32 Max. voltage 600 V 3 Phase Max. urrent 30 A Conforming to standards IEC , , , EN60204, BS484, UL 508, CSA No. 4, NFC , 63-20, 79-30, VDE 03, 0660 Produt approvals UL, CSA BV Protetive treatment TH TH Ambient air temperature operation -58 to 58 o F (-50 to +70 o C) Wiring of ondutors and ross setional area (.s.a.) Max. Min. Solid able 2 #8 AWG (2 6 mm 2 ) 2 #6 (2 mm 2 ) Flexible able without able end 2 #8 AWG (2 6 mm 2 ) 2 #4 (2 mm 2 ) Flexible able with able end 2 #0 AWG (2 4 mm 2 ) 2 #6 AWB (2 mm 2 ) Resistane to mehanial impat onforming to IEC J Tightening torque 5 in-lb (.7 N m) Sensitivity to phase failure No Table 8.: Speifiations Operating Positions: File E64864 CNN NLRV File LR8630 Class Rated voltage 600 V Rated thermal urrent 25 A (GV2), 63 A (GV3) Mehanial life: GV2: 00,000 operations Shok resistane 30 g (onforming to IEC ) Vibration resistane 5 g (5 to 50 Hz) (IEC ) Ambient temperature: -40 to 76 o F (-40 to +80 o C) for storage -4 to 40 o F (-20 to +60 o C) open operation -4 to 04 o F (-20 to +40 o C) enlosed operation Maximum operating life 25 operations per hour Operating urrent of magneti trip is approximately 3 times maximum thermal trip (non-adjustable setting) Shneider Eletri I Disount
4 GV2GH7 LAD3 LAD3 Starters Aessories Table 8.36: GV2 Mounting Aessories TeSys GV2 Manual Starters and Protetors Refer to 2502CT000 Desription Appliation Standard Pak b Eah Common mounting plate For GV2 plus any 3-pole LCD09 thru LCD25 ontator. (supplied with GVG02 onnetor) GK2AF Adapter plate For srew mounting of GV2M 0 GV2AF Interonnet for GV2 plus any 3-pole LCK or LPK ontator 0 GV2AF0 4.0 Combination blok Interonnet GV2 and LCD09 thru D32 0 GV2AF Interonnet GV2 and LCD09 thru D32 mounted on LAD3 0 GV2AF mm ompensation plate To allow mounting of GV2M and GV2P on a ommon bus bar 0 GVF Mounting plate For mounting GV2ME or GV2P and ontator LCD09 thru D32 0 LAD LAD Table 8.37: GV2 Cabling Aessories Bus Bars 3-Pole, 63 A Bus Bar Desription Appliation Pith Standard Pak b Eah For feeding 2 GV2 starters Table 8.38: GV2 Other Cabling Aessories 72 GV2G2 GV2G2 GV2G For feeding 3 GV2 starters GV2G3 GV2G For feeding 4 GV2 starters 72 GV2G4 GV2G4 GV2G For feeding 5 GV2 starters GV2G Desription Appliation Standard Pak b Eah Top feed for use with bus bars GVG Terminal bloks Bottom feed, to be used with bus bars; an be fitted with GVL3 urrent limiter GV2G Protetive end over To over unused bus bar outlets 5 GVG pole flexible onnetor For onneting a GV2 to an LCD09 thru D25 ontator 0 GVG Conduit adapter ( 2" NPT) GV2AK 6.20 Inoming line insulator For GV2P when used in UL 508 Type E appliationsa 0 GV2GH a Cannot be used with front-mounted auxiliary ontat blok. Table 8.39: GV2 Other Aessories Desription Appliation Standard Pak b Eah Visible isolation blok - GV2P Front mount, 3-pole visible isolation on inoming side of GV2P GV2AK Current limiter - GV2M Inreases interrupt apaity when attahed to GV2M GVL Through-Door operator - GV2P For operating GV2P through enlosure door (red handle, yellow legend plate) For NEMA use. IP GV2AP02.00 Table 8.40: GV2 Enlosures Desription Mounting Rating Eah Enlosures for GV2M Surfae mount NEMA, IP4 GV2MC0.00 IP55 GV2MC with or without aessories (maximum of aessory Flush mount NEMA, IP4 GV2MP0 3.0 on right and left) IP55 GV2MP02.00 Enlosures are not UL or CSA listed. Flush mount redued width NEMA, IP4 GV2MP (max. of aessory on right) IP55 GV2MP Table 8.4: GV2 Enlosures Aessories Desription Type Standard Pakb Eah Padloking devie for GV2M (when padloked, starter is automatially in Off position) GV2V Spring return GV2K0.90 Mushroom head stop push button Key release (Ronis key no. 5) GV2K (40 mm, red) Lathing Turn to Release GV2K Lathing / Padlokable Turn to Release GV2K Sealing kit For enlosures GV2MC0 and GV2MP0 0 GV2E V Green 0 GV2SN3 0 V Red 0 GV2SN4 0 V Orange 0 GV2SN5 0 V White 0 GV2SN7 220/240 V Green 0 GV2SN23 Pilot Light (neon) 220/240 V 220/240 V Red Orange 0 0 GV2SN24 GV2SN /240 V White 0 GV2SN27 380/440 V Green 0 GV2SN33 380/440 V Red 0 GV2SN34 380/440 V Orange 0 GV2SN 380/440 V White 0 GV2SN37 b Orders must speify multiples of quantities listed. Supplied with IP55 sealing kit. 8 STARTERS GV2AF3 / GV2AF Shneider Eletri I Disount 8-37
5 Dimensions TeSys Manual Starters and Protetors Refer to 2520CT000 GV2M GV2AD, AM, AN, AU, AS, AX GV2AE Mounting of GV2M Blok GV2AD, AM, AN Blok GV2AU, AS, AX On mm rail C 78.5 mm (3.09") on AMDP200 ( x 7.5 mm) C 86 mm (3.39") on AMDE200, ED200 ( x 5 mm) GV2P GV2AD, AM, AN, AU, AS, AX GV2AK00 Mounting of GV2P Blok GV2AD, AM, AN Blok GV2AU, AS, AX On mm rail C 98.5 mm (3.88") on AMDP200 ( x 7.5 mm) C 06 mm (4.7") on AMDE200, ED200 ( x 5 mm) 8 STARTERS GV2AF4 + LAD3 GV2P + GV2GH7 GV2P + GV2GH7 + TeSys D ontator Combination GV2ME + TeSys D range ontator Combination GV2P + TeSys D range ontator for UL 508 Type E appliation for UL 508 Type E appliation d d.77 b.77 b (9.4) 3.6 (9.4) 3.8 (96.52) 3.8 (96.52) GV2ME + LC2D09 to D8 LC2D25 and D32 GV2P + LC2D09 to D8 LC2D25 and D32 b 7.4 (88.6) 7.8 (99) b 6.6 (68.) 7.9 (99.5) 3.6 (92.7) 3.9 (99) 4.6 (6.8) 4.6 (6.8) 3.9 (98.2) 4. (04.5) 4.8 (22.3) 4.8 (22.3) d 3.9 (98.3) 3.9 (98.3) d 4. (03.8).4 (03.8) Surfae mounting enlosure GV2MC0 Flush mounting enlosure GV2MP0 (braket ut-out) a 2xØ5.3x b b a knok-outs for 6 mm plasti able glands or no. 6 onduit....6 / GV2 b b IN mm IN mm MP0, MP MP03, MP Shneider Eletri
6 Dimensions TeSys Manual Starters and Protetors Refer to 2520CT000 GV2M with GK2AF0 and LCK GV2M with GV2AF0 and LCK GV2M with GV2AF0 and LC2K Adapter plate GK2AF0 dimensions in mm Ø ±5 4.3 ± Mounting external operator GV2AP0 Door ut-out GV2M on panel with GV2AF02 adapter plate 7.5 mm height ompensation plate GVF / min.50 max Sets of bus bars, GV2G4, GV2G4, GV2G472 with terminal blok GV2G l p 4xØ Ø /60.97/2.36 Sets of bus bars with terminal blok GVG Sets of bus bars GV2G2, GV2G2, GV2G272 l 8 STARTERS I P GV2G4 0.6 x.8" (4 x mm) 7.0" (79 mm).8" ( mm) GV2G4 0.6 x 2." (4 x mm) 8." (206 mm) 2." ( mm) GV2G x.8" (4 x mm) 0.2" (260 mm) 2.8" (72 mm) Dimensions GV3 P I GV2G x.8" (2 x mm) 3.5" (89 mm) GV2G x 2." (2 x mm) 3.9" (98 mm) GV2G x 2.8"(2 x 72 mm) 4.6" (6 mm) GV2G3 0.2 x 2." (3 x mm) 6.0" (52 mm) Mounting on rail AM DE200 or AM ED20 36 X X () (2) X Eletrial learane (ISC max) 40 mm for Ue < 500 V, 50 mm for Ue < 690 V Mounting on panel, using M4 srews Bloks GV ANpp, GV ADpp, GV AM Blok GV3 AUpp and GV3 ASpp Mounting on pre-slotted mounting plate AM PA 83 AF EA4 6 3xØ4 37,5 37, ,5 36 8,7 8,7 Note: Leave a spae of 9 mm between 2 manual motor protetors: either an empty spae or side-mounting add-on ontat bloks. Horizontal mounting is possible: please onsult your regional sales offie Shneider Eletri 8-53
TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325
Referenes For motor ontrol up to 75 kw at 400 V, in ategory AC-3 Control iruit: a.., d.. or low onsumption 3-pole ontators for onnetion by srew lamp terminals or onnetors (1) 810356 Standard power ratings
More informationTeSys circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping
More informationGV2ME. Main. Device short name. Device application
Product datasheet Characteristics GV2ME32 TeSys GV2-Circuit breaker-thermal-magnetic - 24...32 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationGV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink
Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.
Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.
Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationGV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals
Product datasheet Characteristics GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - spring terminals Main Range Product name Device short name Product or component type Device application
More informationGV2ME. Main. Device short name. Device application
Product datasheet Characteristics GV2ME10 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2ME Circuit breaker Motor Thermal-magnetic
More informationGV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals
Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology
More informationGV2P05. Main. Device short name. Device application
Product datasheet Characteristics GV2P05 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2P Circuit breaker Motor Thermal-magnetic
More informationautomatic source-changeover system with 2 devices
MEL GE AC-EC292-1 MEL GE AC-EC292-1 U U U U Masterpat: funtions and harateristis mati soure-hangeover systems 025186 Masterpat mati soure-hangeover system 05061 05060 05058 Masterpat soure-hangeover systems
More informationLC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationLC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationGV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori
Podatkovni list proizvoda Karakteristike GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori Glavno Range Product name Device short name Product or component type Device application
More informationLC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationLC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil
Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil
Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.
More informationLC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil
Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil
Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range
More informationLC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationAC1036. Definite Purpose Contactors
Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous
More informationManual Motor Starter Specifcations
Technical Data Manual Motor Starter Specifcations Bulletin 140A Topic Page Product Selection 2 Accessories 3 Specifications 6 Approximate Dimensions 13 Additional Resources These documents contain additional
More informationContactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationAgency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines
More informationSafety dialogue solutions
Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,
More informationllen-bradley 194R-HM4-NFPA3
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationPower Circuit of a UL508A Panel. Typical UL489 Application
Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech
More informationCT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL
Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)
More informationDMX and 4000 air circuit breakers from 800 to 4000 A
DMX 3 20 and 00 air circuit breakers from 800 to 00 NEW 286 56 + 288 02 (p. 4) 286 4 + 288 02 (p. 4) 28 56 + 288 02 (p. 4) Dimensions (p. to 53) Electrical characteristics (p. 54 to 5) ir circuit breakers
More informationType: DILM25 10(24V50HZ) Article No.:
Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationCatalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3
PowerPact Multistandard Catalogue numbers Functions and characteristics A-1 Installation recommendations B-1 Dimensions C-1 Wiring diagrams D-1 Additionals characteristics E-1 H-Frame, J-Frame unit-mount
More informationData sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286
CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have
More informationCircuit-Breakers for Motor Protection Series 8523/8
> Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting
More informationSeries CDP2 Definite Purpose Contactors
Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationSeries CDP2 Definite Purpose Contactors
Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationMinicontactorrelay,2NO/2NC,DCoperated
Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Manual Motor Protectors Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays....................
More informationType: DILM12 10(24VDC) Article No.:
Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More information4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+
/2 Introduction / 5SV RCCBs /10 5SM3 RCCBs /13 SIQUENCE 5SM3/5SU1 universal -sensitive RCCBs, type B and type B+ /18 Additional components /22 5SM2 RC units /30 5SU1 RCBOs /38 5SM6 AFD units /1 5SM6 AFD
More informationData Sheet Definite Purpose Contactors Ex9CK Series
Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed
More informationProtection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type
More informationwith handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...
More informationDIN Power Module - Phase Adaptive
DIN Power Module ow Capacity Phase Adaptive DIN Power Module - Phase Adaptive 369849a 1 08.06.15 The Phase Adaptive Power Module family is a group of modular products for the control of lighting loads.
More informationA V 50Hz / V 60Hz
A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationXT IEC Power Control Combination Motor Controllers
7 Product Family Overview May 007 Contents Description Page Standards and Certifications............. 7 Catalog Selection................ 76 Product Selection.......... 77 Accessories............... 7
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More informationMovable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability
Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide
More informationSQM40/41 Actuators for air and gas dampers
SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The
More informationDatasheet - SRB-E-201ST
27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationType: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles
Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationPart-Turn Electric Multi-Turn Electric
Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1
More informationClimatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC
Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63
Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC
More informationInstallation and User Guide 458/CTR8 8-Channel Ballast Controller Module
Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective
More informationI r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Circuit-breaker,3p,160A Partno. NZMN2-M160 CatalogNo. 265724 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationMagnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A
72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature
More informationKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More informationCAMTO LTD. Arc detecting system DC/AC
CAMTO LTD Arc detecting system DC/AC Arc detecting system DC/AC The system is based on experience with arc protection since 1962. The system units are built into boxes that all fit on a 35 mm DIN-rail.
More informationFeed-through terminal, 4 mm², Screw connection, Wemid, dark beige, TS 35
General ordering data Order No. 1020100000 Part designation WDU 4 Version EAN 4008190150617 Qty. 100 pc(s). Feed-through terminal,, Screw connection, Wemid, dark beige, TS Product notes Note, ordering
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationLXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O
Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control
IEC Contactors and Starters. Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete
More informationDC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.
HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with
More informationSelection guide siemens.com/sirius-modular-system
SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control
Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete motor protection solution by
More informationFeed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35
General ordering data Order No. 1020000000 Part designation WDU 2.5 Version EAN 4008190099633 Qty. 100 pc(s). Feed-through terminal,, Screw connection, Wemid, dark beige, Product notes Note, ordering data
More informationOrdering details. Approval. Classification
Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation