Removal of Cable and Connector Dispersion in Time-Domain Waveform Measurements on 40Gb Integrated Circuits (slide presentation only)
|
|
- Leo Barnett
- 5 years ago
- Views:
Transcription
1 Jan Verspecht bvba Gertrudeveld Steenhuffel Belgium web: Removal of Cable and Connector Dispersion in Time-Domain Waveform Measurements on 40Gb Integrated Circuits (slide presentation only) Jonathan Scott, Babak Behnia, Marc Vanden Bossche, Alex Cognata, Jan Verspecht, Frans Verbeyst, Mark Thorn, Daniel R. Scherrer Used with Permission
2 Removal of Cable and Connector Dispersion (& Jitter) in Time-Domain Waveform Measurements on 40Gb Integrated Circuits Jonathan Scott, Babak Behnia, Jan Verspecht, Marc Vanden Bossche, Alex Cognata, Frans Verbeyst, Mark Thorn, and Daniel R. Scherrer
3 Measurement Problem Cables & connectors ruin fidelity Jitter blurs edges, corrupts averages Instrument bandwidth filters waveform June, 2002 MTT-S Page 2
4 Large-Signal Network Analyzer (LSNA) Hardware similar to a NA» + power meter» + phase reference generator Functions like a scope» Time-domain display» Arbitrary stimulus waveform Calibrates like NA Developed for precision measurement for nonlinear, active device characterization & modeling June, 2002 MTT-S Page 3
5 LSNA Constraints Prototype: 600MHz--50GHz» Soon 50MHz--50GHz» 50MHz-110GHz possible Known signal period Progress to wide release depends upon the company perceiving a market... Calibrate at (anticipate) all frequencies Similar to using sampling scope with directional coupler June, 2002 MTT-S Page 4
6 Calibration Normal 2-port NA calibration first (SOLT,LRM,etc)» Now know ratios of travelling waves at reference planes Power calibration (power ref plane) Power calibration» If on wafer, require extra 1-port cal at a coaxial connector» e.g.: On-wafer thru + coaxial SOL cal at port-2 termination» Now know absolute magnitudes of travelling waves Phase calibration» Substitute comb for sinewave (typically at power cal plane) June, 2002 MTT-S Page 5
7 Reference Comb Generator Phase of tones known Calibrated via nose-tonose sampler calibration Adequate level at all desired frequencies NIST/NPL traceability possible June, 2002 MTT-S Page 6
8 Measurement Setup IC on wafer Bias T, wafer probe & cables required Scope can attach only at arrow ( ) June, 2002 MTT-S Page 7
9 LSNA Hardware Resembles 8510 NA» slightly more complicated test set Power Meter Reference (Comb) Generator Ref Gen Power Meter Signal Gen Downconverter mw Test Set Comb source Power sensor ADC & PC June, 2002 MTT-S Page 8
10 Scope Connection View Requires» Attenuation (pad)» Bias T» Cable (distance, flexibility)» Wafer Probe Worse if scope Remote head is not small-» 4x6x12 (loaf of bread) vs...» 1x2x4 (cigarette packet) June, 2002 MTT-S Page 9
11 Measurement System Risetime 7ps (onwafer!)» Compare 12ps for 50GHz scope Some Gibbs phenomenon No (random) jitter» with NO averaging penalty No slow tail» cable response corrected 40Gb Data Amp at 1.25GB/s June, 2002 MTT-S Page 10
12 Bitstream Measurement Scope/LSNA comparison highlights difference June, 2002 MTT-S Page 11
13 Eye Measurement June, 2002 MTT-S Page 12
14 Eye Measurement Using LSNA:» Transition asymmetry visible» See true overshoot levels» Ripple uncovered» Pattern-dependent jitter (ISI) visible once random jitter reduced Simulation agrees closely with LSNA data June, 2002 MTT-S Page 13
15 Measured vs Simulated (ADS) out_eye time, psec June, 2002 MTT-S Page 14
16 Comparison with latest scopes Faster, smaller sampler modules released 2002» Dispersion Artifact? >80GHz Bw at connector Size allows less cable Dispersion still the limit on wafer! June, 2002 MTT-S Page 15
17 Conclusion LSNA versus scope:» No cable & connection distortion» No instrument response uncertainty» No instrument jitter penalty Precision» UI complicated (product immature)» LF response gap (less serious than it looks) Effort» Expensive (vector, 2-port, traceable) Readily extended in frequency 110GHz possible (t R <3.5ps) June, 2002 MTT-S Page 16
18 Did you say 40GB/s? 40GB/s signals are sinewaves when seen with 50GHz bandwidth--- not interesting ICs are intended for 40GB/s, but tested at lower rates No 40GB source 1 year ago June, 2002 MTT-S Page 17
19 What Happens to Random Jitter? Averaging convolution by jitter PDF (*PDF) Scope averaging fi degrade response (x FT(PDF)) Trigger (instrument LO) jitter is calibrated out Pattern-dependent jitter (ISI) remains---not random Comprehensive discussion in full paper submission June, 2002 MTT-S Page 18
How advances in digitizer technologies improve measurement accuracy
How advances in digitizer technologies improve measurement accuracy Impacts of oscilloscope signal integrity Oscilloscopes Page 2 By choosing an oscilloscope with superior signal integrity you get the
More informationKeysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer. Application Note
Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer Application Note Introduction High-power devices are common building blocks in RF and microwave communication
More informationClock Jitter Cancelation in Coherent Data Converter Testing
Clock Jitter Cancelation in Coherent Data Converter Testing Kars Schaapman, Applicos Introduction The constantly increasing sample rate and resolution of modern data converters makes the test and characterization
More informationSenior Project Manager / AEO
Kenny Liao 2018.12.18&20 Senior Project Manager / AEO Measurement Demo Prepare instrument for measurement Calibration Fixture removal Conclusion What next? Future trends Resources Acquire channel data
More informationGeneration of Novel Waveforms Using PSPL Pulse Generators
Generation of Novel Waveforms Using PSPL Pulse Generators James R. Andrews, Ph.D, IEEE Fellow & Bob McLaughlin PSPL Founder & former President (retired) PSPL Sales Engineer Picosecond Pulse Labs (PSPL)
More informationThe high-end network analyzers from Rohde & Schwarz now include an option for pulse profile measurements plus, the new R&S ZVA 40 covers the
GENERAL PURPOSE 44 448 The high-end network analyzers from Rohde & Schwarz now include an option for pulse profile measurements plus, the new R&S ZVA 4 covers the frequency range up to 4 GHz. News from
More informationCalibrate, Characterize and Emulate Systems Using RFXpress in AWG Series
Calibrate, Characterize and Emulate Systems Using RFXpress in AWG Series Introduction System designers and device manufacturers so long have been using one set of instruments for creating digitally modulated
More informationWhy Engineers Ignore Cable Loss
Why Engineers Ignore Cable Loss By Brig Asay, Agilent Technologies Companies spend large amounts of money on test and measurement equipment. One of the largest purchases for high speed designers is a real
More informationTransmitter Preemphasis: An Easier Path to 99% Coverage at 300m?
Transmitter Preemphasis: An Easier Path to 99% Coverage at 300m?, Jim McVey, The-Linh Nguyen Finisar Tom Lindsay - Clariphy January 24, 2005 Page: 1 Introduction Current Models Show 99% Coverage at 300m
More informationAnalyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note
Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note Products: R&S RTO2002 R&S RTO2004 R&S RTO2012 R&S RTO2014 R&S RTO2022 R&S RTO2024 R&S RTO2044 R&S RTO2064 This application
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 9500B Users Supplement Issue: 2 Part Number: 1625019 Issue Date: 9/06 Print Date: October 2005 Page Count: 6 Version 11 This supplement contains information necessary to ensure the accuracy
More informationSynthesized Clock Generator
Synthesized Clock Generator CG635 DC to 2.05 GHz low-jitter clock generator Clocks from DC to 2.05 GHz Random jitter
More informationRF Characterization Report
BNC7T-J-P-xx-ST-EMI BNC7T-J-P-xx-RD-BH1 BNC7T-J-P-xx-ST-TH1 BNC7T-J-P-xx-ST-TH2D BNC7T-J-P-xx-RA-BH2D Mated with: RF179-79SP1-74BJ1-0300 Description: 75 Ohm BNC Board Mount Jacks Samtec, Inc. 2005 All
More informationA 90 Gb/s 2:1 Multiplexer with 1 Tap FFE in SiGe Technology
A 90 Gb/s 2:1 Multiplexer with 1 Tap FFE in SiGe Technology Ekaterina Laskin, University of Toronto Alexander Rylyakov, IBM T.J. Watson Research Center October 14 th, 2008 Paper H4 Outline Motivation System
More informationExtension kit for R&S Vector Network Analysers
NM300 Data Sheet September 2012 Extension kit for R&S Vector Network Analysers Characterisation of Nonlinear RF/HF Components in Time and Frequency domain Extension kit for R&S Vector Network Analysers
More informationReceiver Testing to Third Generation Standards. Jim Dunford, October 2011
Receiver Testing to Third Generation Standards Jim Dunford, October 2011 Agenda 1.Introduction 2. Stressed Eye 3. System Aspects 4. Beyond Compliance 5. Resources 6. Receiver Test Demonstration PCI Express
More informationRF Measurements You Didn't Know Your Oscilloscope Could Make
RF Measurements You Didn't Know Your Oscilloscope Could Make Application Engineer Keysight Technologies gustaaf_sutorius@keysight.com Oscilloscope as Spectrum Analyzer Introduction Keysight oscilloscopes
More informationPAM4 signals for 400 Gbps: acquisition for measurement and signal processing
TITLE PAM4 signals for 400 Gbps: acquisition for measurement and signal processing Image V1.00 1 Introduction, content High speed serial data links are in the process in increasing line speeds from 25
More informationCombating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels
Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels Why Test the Receiver? Serial Data communications standards have always specified both the transmitter and
More informationCombating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels
Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels Why Test the Receiver? Serial Data communications standards have always specified both the transmitter and
More informationPicoScope 9300 Series migration guide
sampling oscilloscopes since 2009 The 9300 Series is a leading-edge product family resulting from a long program of product development. From late 2017, in the process of adding new 15 GHz and 25 GHz models,
More informationEmphasis, Equalization & Embedding
Emphasis, Equalization & Embedding Cleaning the Rusty Channel Gustaaf Sutorius Application Engineer Agilent Technologies gustaaf_sutorius@agilent.com Dr. Thomas Kirchner Senior Application Engineer Digital
More informationKeysight Technologies De-Embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note
Keysight Technologies De-Embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer Application Note L C Introduction Traditionally RF and microwave components have been designed in packages
More informationKeysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution
Keysight Technologies 802.11ad Waveform Generation & Analysis Testbed, Reference Solution Configuration Guide This configuration guide contains information to help you configure your 802.11ad Waveform
More informationEVLA Fiber Selection Critical Design Review
EVLA Fiber Selection Critical Design Review December 5, 2001 SJD/TAB 1 Fiber Selection CDR Decision about what fiber to install Select cable Jan 2002 Order cable Jan 2002 Receive cable May 2002 Start installation
More informationR&S ZVA-Zxx Millimeter-Wave Converters Specifications
R&S ZVA-Zxx Millimeter-Wave Converters Specifications Data Sheet Version 19.00 CONTENTS Definitions... 3 General information... 4 Specifications... 5 Test port... 5 Source input (RF IN)... 5 Local oscillator
More informationR&S ZVA-Zxx Millimeter-Wave Converters Specifications
ZVA-Zxx_dat-sw_en_5214.2033.22_umschlag.indd 1 Data Sheet 13.00 Test & Measurement R&S ZVA-Zxx Millimeter-Wave Converters Specifications 28.01.2013 15:08:06 CONTENTS General information... 3 Definitions...
More informationElectrical Sampling Modules
Electrical Sampling Modules 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV Datasheet Applications Impedance Characterization and S-parameter Measurements for Serial Data Applications Advanced
More informationMeasurement Accuracy of the ZVK Vector Network Analyzer
Product: ZVK Measurement Accuracy of the ZVK Vector Network Analyzer Measurement deviations due to systematic errors of a network analysis system can be drastically reduced by an appropriate system error
More informationKeysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note
Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer Application Note Table of Contents Coniguration 1 Standard 2-port coniguration... 3 Coniguration 2 Measurements
More informationUSB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1
USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1 Triarchy Technologies Corp. Page 1 of 17 USB Mini Spectrum Analyzer User Manual Copyright Notice Copyright 2013 Triarchy Technologies,
More informationELECTRICAL PERFORMANCE REPORT
CIRCUITS & DESIGN ELECTRICAL PERFORMANCE REPORT DENSIPAC 4 ROW Date: 06-12-2006 Circuits & Design EMEA Circuits & Design 1/21 06/12/2006 1 INTRODUCTION... 3 2 CONNECTORS, TEST BOARDS AND TEST EQUIPMENT...
More information100Gb/s Single-lane SERDES Discussion. Phil Sun, Credo Semiconductor IEEE New Ethernet Applications Ad Hoc May 24, 2017
100Gb/s Single-lane SERDES Discussion Phil Sun, Credo Semiconductor IEEE 802.3 New Ethernet Applications Ad Hoc May 24, 2017 Introduction This contribution tries to share thoughts on 100Gb/s single-lane
More informationRF Record & Playback MATTHIAS CHARRIOT APPLICATION ENGINEER
RF Record & Playback MATTHIAS CHARRIOT APPLICATION ENGINEER Introduction Recording RF Signals WHAT DO WE USE TO RECORD THE RF? Where do we start? Swept spectrum analyzer Real-time spectrum analyzer Oscilloscope
More informationPrecise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN BEAMS DEPARTMENT CERN-BE-2014-002 BI Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope M. Gasior; M. Krupa CERN Geneva/CH
More informationElectrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV
Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV The DSA8300 Series Sampling Oscilloscope, when configured with one or more electrical sampling modules,
More informationAgilent FieldFox RF Analyzer N9912A
Contents Agilent FieldFox RF Analyzer N9912A Quick Reference Guide Do You Have Everything?... 2 The Power Button and LED... 2 Battery Usage... 3 Measure Return Loss... 4 Measure Cable Loss (1-Port)...
More informationComparison Between DRS4 Chip-Based Boards and ADCs for a Flexible PET Electronics
Comparison Between DRS4 Chip-Based Boards and ADCs for a Flexible PET Electronics D. Stricker-Shaver 1, S. Ritt 2, B. Pichler 1 1 Laboratory for Preclinical Imaging and Imaging Technology of the Werner
More informationAgilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012
Revision 1.11 19-Jul 2012 Agilent Method of Implementation (MOI) for HDMI 1.4b Cable Assembly Test Using Agilent E5071C ENA Network Analyzer Option TDR 1 Table of Contents 1. Modification Record... 4 2.
More informationPractical De-embedding for Gigabit fixture. Ben Chia Senior Signal Integrity Consultant 5/17/2011
Practical De-embedding for Gigabit fixture Ben Chia Senior Signal Integrity Consultant 5/17/2011 Topics Why De-Embedding/Embedding? De-embedding in Time Domain De-embedding in Frequency Domain De-embedding
More informationLOW POWER DIGITAL EQUALIZATION FOR HIGH SPEED SERDES. Masum Hossain University of Alberta
LOW POWER DIGITAL EQUALIZATION FOR HIGH SPEED SERDES Masum Hossain University of Alberta 0 Outline Why ADC-Based receiver? Challenges in ADC-based receiver ADC-DSP based Receiver Reducing impact of Quantization
More informationFluke 190-Series II Firmware Upgrade V11.44
Fluke 190-Series II Firmware Upgrade V11.44 Requirements 1. Fluke 190- Series II ScopeMeter with firmware prior to V11.44 2. Supported models are: 190-102, 190-104, 190-062, 190-202, 190-204, 190-502,
More informationLimitations of a Load Pull System
Limitations of a Load Pull System General Rule: The Critical Sections in a Load Pull measurement setup are the sections between the RF Probe of the tuners and the DUT. The Reflection and Insertion Loss
More informationAgilent 8720E Family Microwave Vector Network Analyzers
Agilent 8720E Family Microwave Vector Network Analyzers Data Sheet 8719ET Transmission/reflection vector network analyzer 8719ES S-Parameter vector network analyzer 50 MHz to 13.5 GHz 8720ET Transmission/reflection
More informationGT Dual-Row Nano Vertical Thru-Hole High Speed Characterization Report For Differential Data Applications
GT-16-97 Dual-Row Nano Vertical Thru-Hole For Differential Data Applications 891-007-15S Vertical Thru-Hole PCB 891-001-15P Cable Mount Revision History Rev Date Approved Description A 8/31/2016 R. Ghiselli/G.
More informationUSB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5
USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5 Triarchy Technologies, Corp. Page 1 of 17 USB Mini Spectrum Analyzer User Manual Copyright Notice Copyright 2013
More informationMILLIMETER WAVE VNA MODULE BROCHURE
MILLIMETER WAVE VNA MODULE BROCHURE General Information OML, founded in 1991, is an expert at millimeter wave (mm-wave) measurements. Our successful foundation is built on mm-wave S-parameter measurements,
More informationBe ahead in 5G. Turn visions into reality.
e n e Be ahead in 5G. Turn visions into reality. 5G test solutions ) www.rohde-schwarz.com/5g 20937_003_5G Flyer_3606-8620-32_V0100_170310.indd 3 5G test challenge: Measuring new 5G systems 5G challenges
More informationDesigning High Performance Interposers with 3-port and 6-port S-parameters
DesignCon 2015 Designing High Performance Interposers with 3-port and 6-port S-parameters Joseph Socha, Nexus Technology joe.socha@nexustechnology.com Jonathan Dandy, Tektronix jonathan.s.dandy@tektronix.com
More informationJD725A Cable and Antenna Analyzer - Dual Port
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD725A Cable and Antenna Analyzer - Dual Port Key Features Portable and lightweight handheld instrument Built-in wireless frequency bands as well as the most
More information40G SWDM4 MSA Technical Specifications Optical Specifications
40G SWDM4 MSA Technical Specifications Specifications Participants Editor David Lewis, LUMENTUM The following companies were members of the SWDM MSA at the release of this specification: Company Commscope
More informationSwitching Solutions for Multi-Channel High Speed Serial Port Testing
Switching Solutions for Multi-Channel High Speed Serial Port Testing Application Note by Robert Waldeck VP Business Development, ASCOR Switching The instruments used in High Speed Serial Port testing are
More informationTechniques for Extending Real-Time Oscilloscope Bandwidth
Techniques for Extending Real-Time Oscilloscope Bandwidth Over the past decade, data communication rates have increased by a factor well over 10X. Data rates that were once 1Gb/sec and below are now routinely
More informationHigh-Frequency IC Design & Test Webinar Part 2 (Test) Inphi Corporation June 25, 2003
High-Frequency IC Design & Test Webinar Part 2 (Test) Inphi Corporation June 25, 2003 Introduction! Why this webinar is important Attendees will learn innovative techniques for high-frequency and high-speed
More informationSMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0
Proposed SMPTE Standard for Television Date: TP Rev 0 SMPTE 424M-2005 SMPTE Technology Committee N 26 on File Management and Networking Technology SMPTE STANDARD- --- 3 Gb/s Signal/Data Serial
More informationHP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications
HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications 100 Hz to 26.5 GHz The HP 71910A/P is a receiver for monitoring signals from 100 Hz to 26.5 GHz. It provides a cost effective combination
More informationNCTA Technical Papers
EXPANDED BANDWIDTH REQUIREMENTS IN CATV APPLICATIONS DANIEL M. MOLONEY DIRECTOR, SUBSCRIBERMARKETING JOHN SCHILLING DIRECTOR, RESIDENTIAL EQUIPMENT ENGINEERING DANIELMARZ SENIOR STAFF ENGINEER JERROLD
More informationTroubleshooting Your Design with the TDS3000C Series Oscilloscopes
Troubleshooting Your Design with the 2 Table of Contents Getting Started........................................................... 4 Debug Digital Timing Problems...............................................
More informationTektronix Inc. DisplayPort Standard
DisplayPort Standard 06-12-2008 DisplayPort Standard Tektronix MOI for Sink Tests (AWG Jitter Generation using Direct Synthesis and calibration using Real Time DPO measurements for Sink Devices) DisplayPort
More informationApplication Note DT-AN-2115B-1. DTA-2115B Verification of Specifations
DTA-2115B Verification of Specifations APPLICATION NOTE January 2018 Table of Contents 1. Introduction... 3 General Description of the DTA-2115B... 3 Purpose of this Application Note... 3 2. Measurements...
More informationTest time metrics for TP2 waveforms
Test time metrics for TP2 waveforms Two possible methods to examine pattern waveforms instead of eyes Factors that control test times Accuracy issues Post processing/making measurements Page 1 TP2 waveform
More informationResearch Results in Mixed Signal IC Design
Research Results in Mixed Signal IC Design Jiren Yuan, Professor Department of Electroscience Lund University, Lund, Sweden J. Yuan, Dept. of Electroscience, Lund University 1 Work packages in project
More informationWhat to look for when choosing an oscilloscope
What to look for when choosing an oscilloscope Alan Tong (Pico Technology Ltd.) Introduction For many engineers, choosing a new oscilloscope can be daunting there are hundreds of different models to choose
More informationProspect and Plan for IRS3B Readout
Prospect and Plan for IRS3B Readout 1. Progress on Key Performance Parameters 2. Understanding limitations during LEPS operation 3. Carrier02 Rev. C (with O-E-M improvements) 4. Pre-production tasks/schedule
More informationMemory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope
Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope Application Note 1495 Table of Contents Introduction....................... 1 Low-frequency, or infrequently occurring jitter.....................
More informationThe EMC, Signal And Power Integrity Institute Presents
The EMC, Signal And Power Integrity Institute Presents Module 12 Pre-emphasis And Its Impact On The Eye Pattern And Bit-Error-Rate For High-Speed Signaling By Dr. David Norte Copyright 2005 by Dr. David
More informationMCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010
MCP Signal Extraction and Timing Studies Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010 Outline Studying algorithms to process pulses from MCP devices. With the goal of
More informationUSB Mini Spectrum Analyzer User s Guide TSA5G35
USB Mini Spectrum Analyzer User s Guide TSA5G35 Triarchy Technologies, Corp. Page 1 of 21 USB Mini Spectrum Analyzer User s Guide Copyright Notice Copyright 2011 Triarchy Technologies, Corp. All rights
More information2016 PDV Conference. Time Alignment of Multiple Real-Time High Bandwidth Scope. Channels
Time Alignment of Multiple Real-Time High Bandwidth Scope Channels 1 Time Synchronization Between Scope Channels for Data Acquisition Large Acquisition Systems Often Require Synchronization of Multiple
More informationGHz Sampling Design Challenge
GHz Sampling Design Challenge 1 National Semiconductor Ghz Ultra High Speed ADCs Target Applications Test & Measurement Communications Transceivers Ranging Applications (Lidar/Radar) Set-top box direct
More informationTP1a mask, noise and jitter for SRn
TP1a mask, noise and jitter for SRn Piers Dawe Avago Technologies IEEE P802.3ba Quebec May 2009 TP1a mask, noise and jitter for SRn 1 Supporters Mike Dudek Jonathan King Brian Misek John Petrilla Independent*
More informationMicrowave Interconnect Testing For 12G-SDI Applications
DesignCon 2016 Microwave Interconnect Testing For 12G-SDI Applications Jim Nadolny, Samtec jim.nadolny@samtec.com Corey Kimble, Craig Rapp Samtec OJ Danzy, Mike Resso Keysight Boris Nevelev Imagine Communications
More informationKeysight FieldFox Microwave Analyzers
Quick Reference Guide Contents Keysight FieldFox Microwave Analyzers Do you have everything?... 1 The Power Button and LED... 1 Battery Usage... 2 Measure Return Loss (CAT Mode)... 3 Measure 1-Port Cable
More informationBasic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal. Application Note
Basic RF Amplifier Measurements using a R&S ZNB Analyzer and SMARTerCal Mark Bailey 2013-03-05, 1ES, Version 1.0 Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal.
More informationAdvanced Test Equipment Rentals ATEC (2832)
E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar
More informationBasic Verification of Power Loadpull Systems
MAURY MICROWAVE 1 Oct 2004 C O R P O R A T I O N Basic Verification of Power Loadpull Systems Author: John Sevic, MSEE Automated Tuner System Technical Manager, Maury Microwave Corporation What is Loadpull
More informationBoosting Performance Oscilloscope Versatility, Scalability
Boosting Performance Oscilloscope Versatility, Scalability Rising data communication rates are driving the need for very high-bandwidth real-time oscilloscopes in the range of 60-70 GHz. These instruments
More informationImproving the accuracy of EMI emissions testing. James Young Rohde & Schwarz
Improving the accuracy of EMI emissions testing James Young Rohde & Schwarz Q&A Who uses what for EMI? Spectrum Analyzers (SA) Test Receivers (TR) CISPR, MIL-STD or Automotive? Software or front panel?
More informationLow Level RF for PIP-II. Jonathan Edelen LLRF 2017 Workshop (Barcelona) 16 Oct 2017
Low Level RF for PIP-II Jonathan Edelen LLRF 2017 Workshop (Barcelona) 16 Oct 2017 PIP-II LLRF Team Fermilab Brian Chase, Edward Cullerton, Joshua Einstein, Jeremiah Holzbauer, Dan Klepec, Yuriy Pischalnikov,
More informationAgilent 86100C Infiniium DCA-J
Agilent 86100C Infiniium DCA-J The fastest way to the right answer Time Domain Reflectometer Digital Communications Analyzer The multi-functional analysis tool Wide Band Oscilloscope Jitter Analyzer DCA-J:
More informationApplication Note DT-AN DTU-315 Verification of Specifications
DTU-315 Verification of Specifications APPLICATION NOTE January 2018 Table of Contents 1. Introduction... 3 General Description of the DTU-315... 3 Purpose of this Application Note... 3 2. Measurements...
More informationAFRL-RY-WP-TR
AFRL-RY-WP-TR-2017-0172 SIGNAL PROCESSING UTILIZING RADIO FREQUENCY PHOTONICS Preetpaul S. Devgan RF/EO Subsystems Branch Aerospace Components & Subsystems Division SEPTEMBER 2017 Final Report See additional
More informationHalf-Rate Decision-Feedback Equalization Di-Bit Response Analysis and Evaluation EDA365
DesignCon 2008 Half-Rate Decision-Feedback Equalization Di-Bit Response Analysis and Evaluation Jihong Ren, Rambus Inc. jren@rambus.com Brian Leibowitz, Rambus Inc. Dan Oh, Rambus Inc. Jared Zerbe, Rambus
More informationVXIbus Microwave Downconverter
1313B Phase Matrix, Inc ṬM Instruments You Can Count On VXIbus Microwave Downconverter High-Performance Downconversion For Analysis of Microwave Signals 1 MHz to 26.5 GHz Frequency Range -135 to +30 dbm
More informationKeysight N1055A Remote Head Module 35/50 GHz 2/4 Port TDR/TDT
Keysight N1055A Remote Head Module 35/50 GHz 2/4 Port TDR/TDT For the 86100D DCA-X Series Oscilloscope Mainframe Data Sheet Engineered for easy, accurate impedance and S-parameter measurements on multi-port
More informationThe Challenges of Measuring PAM4 Signals
TITLE The Challenges of Measuring PAM4 Signals Panelists: Doug Burns, SiSoft Stephen Mueller, Teledyne LeCroy Luis Boluña, Keysight Technologies Mark Guenther, Tektronix Image Jose Moreira, Advantest Martin
More information100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013
100GBASE-SR4 Extinction Ratio Requirement John Petrilla: Avago Technologies September 2013 Presentation Summary Eye displays for the worst case TP1 and Tx conditions that were used to define Clause 95
More informationWideband Downconverters With Signatec 14-Bit Digitizers
Product Information Sheet Wideband Downconverters With Signatec 14-Bit Digitizers FEATURES 100 khz 27 GHz Frequency Coverage 3 Standard Selectable IF Bandwidths 100 MHz, 40 MHz, 10 MHz 3 Optional Selectable
More informationSoftware vs Hardware Machine Control: Cost and Performance Compared
Software vs Hardware Machine Control: Cost and Performance Compared SOFTWARE VS HARDWARE MACHINE CONTROL WHITE PAPER SOFTWARE VS. HARDWARE MOTION CONTROL WHITE PAPER In this paper, we will compare a software-based
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 48-3 2011 Test Procedure for Measuring Shielding Effectiveness of Braided Coaxial Drop Cable Using the GTEM Cell
More informationInterface Practices Subcommittee SCTE STANDARD SCTE Hard Line Pin Connector Return Loss
Interface Practices Subcommittee SCTE STANDARD SCTE 125 2018 Hard Line Pin Connector Return Loss NOTICE The Society of Cable Telecommunications Engineers (SCTE) / International Society of Broadband Experts
More informationN4917BACA Optical Receiver Stress Test Solution 100 Gb/s Ethernet
N4917BACA Optical Receiver Stress Test Solution 100 Gb/s Ethernet 25GBASE-LR/-ER/-SR, 100BASE-LR4/-ER4/-SR4 and MSAs Complete optical receiver stress test solution for 100GbE optical transceivers with
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Mainline Pin (plug) Connector Return Loss
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 125 2007 Mainline Pin (plug) Connector Return Loss NOTICE The Society of Cable Telecommunications Engineers (SCTE)
More informationCable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief
Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators Technical Brief Quickly and easily apply a level correction table to compensate for external losses or power variations
More informationAdvanced Skills with Oscilloscopes
Advanced Skills with Oscilloscopes A Hands On Laboratory Guide to Oscilloscopes using the Rigol DS1104Z By: Tom Briggs, Department of Computer Science & Engineering Shippensburg University of Pennsylvania
More information30 GHz Attenuator Performance and De-Embedment
30GHz De-Embedment Application Note - Page 1 of 6 Theory of De-Embedment. Due to the need for smaller packages and higher signal integrity a vast majority of todays RF and Microwave components are utilizing
More informationKeysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution. Solution Brochure
Keysight Technologies 802.11ad Waveform Generation & Analysis Testbed, Reference Solution Solution Brochure 02 Keysight 802.11ad Waveform Generation & Analysis Testbed, Reference Solution - Solution Brochure
More information40G SWDM4 MSA Technical Specifications Optical Specifications
40G SWDM4 MSA Technical Specifications Specifications Participants Editor David Lewis, LUMENTUM The following companies were members of the SWDM MSA at the release of this specification: Company Commscope
More informationMM-wave Partial Information De-embedding: Errors and Sensitivities. J. Martens
MM-wave Partial Information De-embedding: Errors and Sensitivities J. Martens MM-wave Partial Information De-embedding: Errors and Sensitivities J. Martens Anritsu Company, Morgan Hill CA US Abstract De-embedding
More information100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013
100G SR4 Link Model Update & TDP John Petrilla: Avago Technologies January 2013 100G 100m Transceivers Summary Presentation Objectives: Provide an update of the example link model for 100G 100m MMF Discuss
More information