EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

Similar documents
Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Electronic Timer Control Day Astronomic Electronic Control

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

Installation and Operation Manual. YMP Series Signal Programmer

GRASSLIN - DEFROST TIMER GRASSLIN DTMV SERIES SPECIFIERS GUIDE

Inserting the batteries. Basic settings of the remote control

TORK MODEL DZM200A 2 CHANNEL DIGITAL TIME SWITCH WITH MOMENTARY CONTACT

TORK MODEL DWZ100A 1 CHANNEL DIGITAL TIME SWITCH

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

SSPT724A Timer Quick Start Guide

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

Overview: Specifications: Installation Instructions:

OPERATION AND MAINTENANCE

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

A Motor can be in many groups, by assigning additional channel# on it.

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

TDDFM14 OWNER S MANUAL

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Comfort System T-32-P Universal Thermostat. Operation Manual

1 Channel Multi-Purpose Programmer User Instructions

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

7 Day Digital Programmer 3 Channel Surface Mount

Dimensions and Weight Size 2.79 HEIGHT X 1.6 WIDTH X 1.19 DEPTH IN, HEIGHT X WIDTH X DEPTH MM

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

Electronic 1-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Electronic 2-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

Installation & Programming Manual. Please read before using this timer.

16 Amp Electronic 24 Hour/7 Day Time Controller

Master Clock Controller. User Guide. pyramidtimesystems.com

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

Softwired Clock. Total Lighting Control. Catalog Number: RCLK8SWS DESCRIPTION FEATURES. Installation Instructions IMRCLK8SWS 1

EN Wireless programmable thermostat

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

Off Site Maintenance Goes Mobile Electronic Cellular Time Switch

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Master Time Clock MTC Users Manual

Modular Lube Lubrication Systems System Controls

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

User s Guide. ECx Features: Automatic Sprinkler System Timer

Master Clock Controller. User Guide. pyramidtimesystems.com

User s Guide. GreenKeeper 212 Features: Automatic Sprinkler System Controller

7 Day Digital Programmer

ComfortChoice Touch Thermostat. Designed for ZigBee R Wireless Technology USER GUIDE

Master Clock Controller. User Guide. pyramidtimesystems.com

User s Guide. ECx Features: Automatic Sprinkler System Timer

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

Digital Time Switch. Installation & Operating Instructions

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Philips LightMaster. KNX Timeclock Installation and Operation Manual

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

) AMANO. ,i CINCINNATI ELECTRONIC TIME RECORDER EX 6000 SERIES

Operation Guide 6022 ENGLISH

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Junior Max (JR Max ) Controller

XTM72E & F Real-Time Clock Modules

Three Phase - General Purpose. THREE PHASE: 3 kva - 9 kva Epoxy Encapsulated Series 76 ISO-Shield

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

INSTALLATION, PROGRAMMING AND OPERATION MANUAL

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Battery Operated Controllers

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Waterline Room Controller - Type WLCT3

Mechanical Time Switches

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

TouchNet. Central Control System for OSMAC. User s Guide. Installation Programming Operation Service

Magnecraft Power Relays

MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

DCP100 Digital Control Programmer Specifications

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

Integrated Remote Commander

7 Day Digital Time Switch

ST9100C User Guide. Features

Stage Right Party 10-Watt Mini Beam Moving Head LED Light

Part-Turn Electric Multi-Turn Electric

FD Trinitron Colour Television

Automatic Transfer Switch Control PLC Operator s Manual

HEVAC HTC DIGITAL SERIES STEP BY STEP GUIDE FOR COMMON PROGRAMMING

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

USER & ENGINEER INSTRUCTION MANUAL

Cronotermostato Digitale

Transcription:

http://waterheatertimer.org/paragon-timers-and-manuals.html#ec Replacement timer http://waterheatertimer.org/intermatic-et-series-timers-and-manuals.html#et1700 EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls GENERAL INSTRUCTIONS SPECIFIC CAPABILITIES 16 Setpoints - A setpoint defines the type of event (ON, OFF or duration) as well as the time and day(s) on which the event will occur. 24-hour or 7-day Programming - Allows the same schedule or a different schedule for each day of the week. Selectable Clock Format - 12 hour (AM/PM) or 24 hour format. Manual Override - Reverses current output state; begins immediately when initiated and remains until overridden again or until next setpoint is reached.

INTRODUCTION The EC7000, EC7004 and EC7005 are single-channel, electronic time control that provides simple, inexpensive control of lighting, heating, ventilation, air-conditioning, security systems, motors, pumps, fans or any load with a time-of-day schedule. The control may be utilized as a 24-hour or 7-day control. as a 24-hour control, the same ON/OFF program is utilized each day of the week. Saturday and/or Sunday, or any other day may be skipped. When schedules vary from day to day, the 7-day programming capability allows a different schedule for each day of the week. With 16 setpoints available, this time control provides programming versatility. The EC7001 provides two individually programmable durations of 1-59 seconds in addition to the maintained ON and OFF setpoints. This provides ideal control for the ringing chimes, school bells, factory bells, remote animal feeders, and air and water purity samplers. On events can be combined with duration events to obtain to-the-second ON times such as one minute and fifteen seconds or two minutes and thirty seconds, providing excellent control for loads that require precise ON durations longer then 59 seconds. EC7000 SPDT EC7004 SPST N L (24, 120 or 277) L2 L1 (208 or 240) N L (120 or 277V) L2 L1 (208 or 240V) EC7005 SPST See jumpers below 1 2 3 4 120V jumpers 1 2 3 4 208 or 240V jumpers L N (120v) L1 L2 (208 or 240V) L N (277V no jumpers needed)

Output UL Ratings CONTACT RATINGS CSA Ratings EC7000 EC7000 Normally open contacts: Normally open contacts: 20 amp resistive at 24-240 Vac 10 amp resistive at 24-240 Vac 1 Hp at 120 Vac 1/2 Hp at 120 Vac 2 Hp at 240 Vac 1 Hp at 240 Vac 5 amp tungsten at 120-240 Vac 5 amp tungsten at 120-240 Vac 6 amp ballast at 277 Vac Normally closed contacts: Normally closed contacts: 10 amp resistive at 24-240 Vac 10 amp resistive at 24-240 Vac 1/4 Hp at 120 Vac 1/4 Hp at 120 Vac 1/2 Hp at 240 Vac 1/2 Hp at 240 Vac 3 amp tungsten at 120-240 Vac 3 amp tungsten at 120-240 Vac 3 amp ballast at 120-277 Vac 3 amp ballast at 120-277 Vac EC7004 EC7004 Normally open contacts: Normally open contacts: 30 amp resistive at 24-240 Vac 30 amp resistive at 120 Vac 1 Hp at 120 Vac 10 amp resistive at 240 Vac 2 Hp at 240 Vac 1 Hp at 120 Vac 5 amp tungsten at 120-240 Vac 2 Hp at 240 Vac 6 amp ballast at 120-277 Vac 5 amp tungsten at 120-240 Vac 6 amp ballast at 277 Vac EC7005 Please refer to inner door instructions on unit or contact factory NOTE: Paragon solid state controls utilize dry contacts, input power enables the control to keep time, store programmed information and carry out instructions but input power does not power the load. To make circuits function, you must provide power to the contacts.

WIRING Terminals can accommodate 10-16 AWG wire. POWER OUTAGE CARRY-OVER The program and time-of-day are maintained during a power outage for a minimum of 4 days. A built-in special capacitor eliminates the inconvenience of battery replacement. ENVIRONMENTAL EC7000 & EC7004 should be mounted indoors in an environment that is free from excessive contaminants such as oil, moisture and dirt. EC7005 is suitable for both indoor and outdoor use. PHYSICAL EC7000 and EC7004 Monuting- EC7005 Mounting- NEMA 1 enclosure mounting NEMA 3 enclosure mounting Weight - Approx. 2 lbs.(0.9kg) Weight - Approx. 3 lbs.(1.4kg) Dimensions- Dimensions- Width 10.8 cm (4-1/4 ) Width 16.7 cm (6-9/16 ) Height 20.0 cm (7-7/8 ) Height 23.1 cm (8-1/8 ) Depth 7.6 cm (3 ) Depth 9.8 cm (3-7/8 ) EC7000 Bracket Mounting Dimensions- Width 10.4 cm (4-1/8 ) Height19 cm (7-1/2 ) Depth 6.7 cm (2-5/8 )

KEYPAD DESCRIPTION EC7000, EC7004 and EC7005 RUN- Returns timer to the RUN mode. The timer will only control the load when in the RUN mode. MODE- Advances from one programming mode to the next. the order of programming modes is as follows: Clock Format Select, Run, Set Time, Setpoint Programming, Set Duration 1 and Set Duration 2. After the last mode, the control will loop back to the Run Mode. " Rolls through the parameter currently being programmed. ENTER- In all programming modes, what is shown in the display is what exists in memory. Pressing the ENTER key simply advances to the next parameter to be programmed. (i.e. hours to minutes).

UNDERSTANDING SETPOINTS Before you begin programming, make sure you understand setpoints and durations. A setpoint defines the type of event - ON, OFF or momentary, as well as the time of the event and the day(s) on which the event will occur. For example, to turn the lights on at 8: A.M each day of the week, a setpoint like this would be required: ON 8:00 A.M., Mon-Tue-Wed-Thur-Fri-Sat-Sun. Setpoint programming provides built-in skip-a-day capability; to skip any day(s), simply do not add the day(s) to the setpoint. As a simple example, consider the following schedule for turning lights on and off. SUN: No lighting required MON through FRIDAY: Lights ON at 7:30 AM, OFF at 5:30 PM SAT:On at 7:30 AM, OFF at 12:30 PM NOTE: When programming, no on the display means no event is required at that setpoint on the particular day. YES means an event is required (either on or off) at that setpoint on that day. The sample schedule would be arranged as follows: 1st setpoint: required: (ON at 7:30 AM Monday through Saturday only) Set as follows - SUN: no MON through SAT:(YES) ON at 7:30 AM 2nd setpoint: required: (OFF at 5:30 PM Monday through Friday only) Set as follows - SUN: no MON through FRI:(YES) OFF at 5:30 PM SAT: no 3rd setpoint: required: (OFF at 12:30 PM Saturday only) Set as follows - SUN through FRI: no SAT:(YES) OFF at 12:30 PM

PROGRAMMING INSTRUCTIONS These timers initially power up in the Clock Format Select Mode. This mode is only accessible once. If the clock format needs to be changed, the timer will have to be reset. To reset the timer, insert a pointed object into the reset hole to the right of the display. CLOCK FORMAT SELECT mode STEP KEY DESCRIPTION 1. Apply power to timer. Control displays 12 Hr, indicating 12 hour clock format. 2. " Toggles between 12 hour (AM/PM) and 24 hour (17:00 = 5:00 P.M.) clock formats. Choose the format desired. 3. ENTER Advances to RUN mode. SET TIME mode STEP KEY DESCRIPTION 1. MODE Advances to SET TIME mode. Control displays time with hours flashing. TOD is also displayed to indicate that Time of Day is being set. 2. " Advance to current hour. 3. ENTER Minutes begin flashing. 4. " Advance to current minute. 5. ENTER Day of week begins flashing. 6. " Advance to current day of week, then go directly to setpoint programming mode below.

SETPOINT PROGRAMMING mode (Refer to Understanding Setpoints and your worksheet.) STEP KEY DESCRIPTION 1. MODE Advances from the SET TIME mode to the SETPOINT PROGRAMMING mode. The timer displays 1 at bottom of display and :. The 1 indicates that the first of 16 setpoints is being programmed. The dashes indicate that this setpoint is clear. 2. ENTER Display shows SU and no. This indicates that Sunday is not included in the setpoint. 3. " Display toggles between YES and no. If the event is desired for the particular day select YES, if not select no. Then go to step 4 on next page. 4. ENTER Display shows MO and no. Repeat steps 3 and 4 to select which day(s) to include in the setpoint. After programming Saturday, the display will show the setpoint with the hours flashing. Dashes in the hour location indicate that the setpoint is still clear. 5. " Advance to desired hour. 6. ENTER Minutes begin flashing. 7. " Advance to desired minute. 8. ENTER Event type begins flashing. 9. " Display toggles between ON and OFF event types. Choose the type of event desired. 10. ENTER Advances to next setpoint. Repeat steps 2 through 10 to program additional setpoints. When all setpoints required, are programmed, advance to steps 11. 11. RUN Returns to the RUN mode when programming is complete. NOTE: Once programming has been completed through step 11, the display should sow correct Time-of-Day, Dayof-Week and Setpoint status (ON/OFF). If present load status should be an ON event, but shows as on OFF event, press ENTER/OVR to turn load ON and to initiate programmed schedule.

TO REVIEW SETPOINTS STEP KEY DESCRIPTION 1. MODE Advances from RUN mode to SET TIME mode. (TOD displays.) 2. MODE Advances from SET TIME mode to SETPOINT PROGRAMMING mode. The control will display the first setpoint (1 displays at bottom.) To modify the setpoint, go to step 2 of the SETPOINT PROGRAMMING mode instructions. 3. " Advance through the remaining setpoints. 4. RUN Returns to RUN mode when done reviewing setpoints. OVERRIDE: Manual override reverses the current output state. loads that are ON turn Immediately OFF; loads that are OFF turn immediately ON. The timer displays OVR to indicate that the current load state is the result of an override. the override remains in effect until overridden again or until the next setpoint is reached. To initiate override, press OVR (ENTER) key while in the RUN mode. NOTE: After an override has been initiated the OVR will display until the next programmed setpoint is reached, even if the timer is overridden again. Display will show if the load is on or off.

TROUBLESHOOTING TIPS Problem Nothing happens when a setpoint occurs to turn the load ON or OFF. Solution Review programmed setpoints making sure the day has not been skipped. Problem You wish to clear the control s memory and start over. Solution Depress the reset switch to the right of the display. Problem Manual override does not work. Solution Check the load for proper wiring. remember, the contacts on these units only switch what is applied to them. (Dry or isolated contacts.) Problem Blank Display Solution Check the input power source, insure proper connection. Problem Control does not operate after programming. Solution If programming was not performed (changing clock time or entering a setpoint) the control will not update itself. Press the ENTER key and override the load until the next scheduled setpoint. Customer Service 800-951-5526 Technical Support 800-732-8400 ISO 9002 registered Maple Chase Company 2820 Thatcher Road Downers Grove, Illinois 60515 Made in Mexico Paragon Electric Canada, Ltd. 5875 Kennedy Road Mississauga, Ontario L4Z 2G3 From outside North America 630-719-5500 110-724B