TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

Similar documents
MAKING MODERN LIVING POSSIBLE. TS715Si Electronic Single Channel Timeswitch with Service Interval Timer. Installation Guide.

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

EN Wireless programmable thermostat

Radio Thermostat Clock

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Programmable Room Thermostat With RF

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

7 Day Digital Light Switch with Optional Dusk Start

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

7 Day Digital Programmer

Cronotermostato Digitale

7 Day Digital Programmer 3 Channel Surface Mount

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Comfort System T-32-P Universal Thermostat. Operation Manual

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

7 Day Digital Time Switch

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

Model IQ4-PC User Manual Revision Date:

Luminaire installation box Surface-mounted box Ceiling installation box

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Digital Time Switch. Installation & Operating Instructions

Innovative Air Systems ABN When Calling For Support Quote:.doc

HS-509 VIBRATION TRIP MODULE

XTM72E & F Real-Time Clock Modules

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

TDDFM14 OWNER S MANUAL

OPERATION AND MAINTENANCE

ST625TX Digital Room Thermostat

16 Amp Electronic 24 Hour/7 Day Time Controller

Operating Instructions

XTM72 Exerciser Timer Module

APOLO DC B Electric Thermal Radiators

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

ST9100C User Guide. Features

Digital Economy Seven Programmer

SAUTER flexotron RDT405 Manual

INSTALLATION & USER GUIDE

ChannelPlus H17XL Series 2 User Operating Instructions

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Multifunction Digital Timer

USER & ENGINEER INSTRUCTION MANUAL

STX Stairs lighting controller.

Aspect 2 Circuit Digital Scene Control

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Instruction Manual for Programmable Digital Timer

ServicePlus S17R Series 2 User Operating Instructions

4 Wiring Brochure Wiring and installation of specific control

ZoneTouch V2 Zone Control System User Manual

Junior Max (JR Max ) Controller

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

OUTDOOR IRRIGATION CONTROLLER LDC-6 LDC-11. User Manual

Waterline Room Controller - Type WLCT3

SAPLING WIRED SYSTEM

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Operating instructions. Universal timer switch display

.Power Distribution Center. PD-1. Instruction Manual

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Sample BD Tech Concepts LLC

Inserting the batteries. Basic settings of the remote control

SceneStyle2 User Guide

Operation Guide 6022 ENGLISH

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Schneider Industries SAS MTN5812../MTN MTN Time switch

Style 5S Clock / Timer

Arduino Nixie Clock Classic Rev4 and Rev5 All In One Modular Rev2

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Chronothermostat IRIDE. User Manual

User s Manual. LG Industrial Systems G3F AT4A. LG Programmable Logic Controller

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Arduino Nixie Clock Modular Rev3

INSTRUCTION & INSTALLATION GUIDE

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor

multi-function meters

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Electronic Timer Control Day Astronomic Electronic Control

Standard RS232 RS ma

DCP100 Digital Control Programmer Specifications

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

3214NXT. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

T775L Series 2000 Electronic Stand-Alone Staging Controller

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Operating instructions III / 2004

KNX Dimmer RGBW - User Manual

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

REGO Start&Go USER MANUAL

Arduino Nixie Clock Classic Rev4 and Rev5 All In One

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Danfoss Icon Programmable Room Thermostats, 230 V

Operating Instructions. Room temperature controller with clock

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Transcription:

TP7001 Range Electronic 7 Day Programmable Room Thermostat Danfoss Heating Installation Guide

For a large print version of these instructions please call Marketing on 0845 121 7400. Certification Mark Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 2 TP7001

Installation Instructions TP7001 Range Electronic Programmable Room Thermostat Index 1.0 Installation Guide...4 2.0 System Overview...4 3.0 Installation...5 3.1 Removing the wallplate...5 3.2 Installation considerations...5 3.3 Affixing the backplate...5 3.4 Wiring...6 3.5 Batteries...6 3.6 Tamperproof operation...7 3.7 Mounting the unit...7 3.8 Unit startup...7 4.0 Installer Advanced Programming Options...7 4.1 Service Interval Timer...7 4.2 Entering Installer Advanced Programming...8 5.0 Reset Procedure... 17 5.1 Partial Reset... 17 5.2 User Reset... 17 5.3 Installer Reset... 17 Danfoss Heating 3

1.0 Installation Guide Please Note: This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations. 2.0 System Overview Thermostat Features TP7001 TP7001M Power supply Memory backup Factory set calendar clock Switching action of output relay Switch rating of relay contact Remote sensor inputs Rated Impulse Voltage Dimensions (mm) 2 x AA/MN1500/LR6 230V ± 15% 50Hz alkaline batteries Retained for the life of the product Automatic summer/winter time change 1 x SPDT, Type 1B 3(1) A, 10-230 Volts Up to three remote sensors, which can be set by the installer for remote temperature sensor, limit sensor, outdoor sensor, window contact or telephone activated switch contacts 2.5 kv 140 wide x 91 high x 28 deep Ball Pressure Test 75 C Temperature Range 5-30 C Design Standard EN 60730-2-7 Control Pollution Situation Degree 2 Time accuracy Temperature accuracy ± 1 minute per month ±1 C 4 TP7001

3.0 Installation 3.1 First remove the wallplate from the back of the unit. 3.2 From the top left hand corner of the wallplate, there must be clearances of at least 21mm to the right, 21mm to the left, 36mm above and 106mm below in order to mount the plug-in module. 3.3 Fix the TP70001/TP7001M and its optional remote room sensor at a height of approximately 1.5m from the floor, away from draughts or heat sources such as radiators, open fires or direct sunlight. Danfoss Heating 5

3.4 For wiring connections please refer to the diagrams below: Battery Version Room/outdoor/limit sensor or contact 1 2 3 4 5 6 7 b C d S COM Mains Powered Version HTG OFF HTG COM HTG ON Z Y Power Supply X 1 2 3 4 5 6 7 8 9 10 b C d S COM X, Y and Z can be connected to Room/Outdoor/Limit Sensor or contact HTG COM HTG ON HTG OFF L N The TP7001 and TP7001M can incorporate three inputs/sensor types by using input b, C and d. The sensor types are as follows: 1) Remote room temperature sensor (sold as an accessory). 2) Limit sensor, for example, floor temperature sensor (sold as an accessory). Note: F10 in display - The underfloor temperature has exceeded the threshold temperature. 3) Outdoor sensor (sold as an accessory). 4) Window contacts, card reader contacts or teleswitch contacts. Note: See Installer Advanced Programming Options for set-up instructions. 3.5 For the TP7001 battery version, insert the batteries making sure that they are correctly oriented. 6 TP7001

3.6 The unit can be made tamperproof if required by setting the DIL switches which will disable the keyboard, and/or the reset functions. The DIL switches are located on the back of the unit. SW. No OFF ON SW.1 SW.2 Keyboard Disabled Reset Disabled Keyboard Enabled Reset Enabled 3.7 Mount the unit on the wallplate Note: Always switch the mains off first and never fit/remove the thermostat to/ from a live wallplate. 3.8 With the unit powered up, it is recommended to press and release the RESET button to start up the TP7001 unit. 4.0 Installer Advanced Programming Options The TP7001 incorporates a number of advanced features which can be set by the user. These are accessed via the User Advanced Programming Mode, please refer to User Advanced Programming in the User Instructions for details. The TP7001 incorporates an additional number of advanced features which can be set by the installer to improve the operating efficiency of the system and where required, to change the user functionality of the product. These are accessed via an Installer Advanced Programming Mode. These settings are optional and need only be accessed if there is a demand for the enhanced functions. 4.1 Service Interval Timer Instructions on how to access this feature are available from our customer support desk. Please note these are only issued to boni-fide heating installers. Danfoss Heating 7

4.2 Entering Installer Advanced Programming To access the Installer Advanced Programming Mode follow the steps below: a) Press and hold V and PROG for 3 seconds to enter User Advanced Programming, the display will change to look like the image opposite. b) Press and hold V, Λ and PROG for 5 seconds to enter Installer Advanced Programming, the display will change to look like the image opposite. c) Use the + and - keys to scroll backwards and forwards between options then the V and Λ keys to change the option settings. The flashing digits in the centre of the display indicate the number of the selected option. The large characters in the top or bottom of the display indicate the option value selected. d) To return to RUN, press and hold PROG until the display returns to previous RUN mode. Option 30 - Set Temperature Upper Limit This allows the upper limit of the thermostat setting range to be limited. Press + until Option 30 is displayed, use V or Λ to select required setting. Can be set to any value between 40.0 C and 5 C in 0.5 C steps Factory setting = 30 C 8 TP7001

Option 31 - Set Temperature Lower Limit This allows the lower limit of the thermostat setting range to be limited. Press + until Option 31 is displayed, use V or Λ to select required setting. Can be set to any value between 5.0ºC and 40.0ºC in 0.5ºC steps Factory setting = 5ºC Option 32 - Enable Off at Lower Limit This enables an OFF function to be selected if a set point below the lower limit is selected. Press + until Option 32 is displayed, use V or Λ to select required setting. 0 = Disabled 1 = Enabled (Factory setting) Option 33 - Enable On at Upper Limit This enables an ON function to be selected if a set point above the upper limit is selected. Press + until Option 33 is displayed, use V or Λ to select required setting. 0 = Disabled (Factory setting) 1 = Enabled Option 34 - Select On/Off or Chrono-Proportional This allows the thermostat to be set to run in On/Off mode or for a chrono-proportional cycle rate to be selected. Press + until Option 34 is displayed, use V or Λ to select required setting. 0 = On/Off 3 = 3 cycles/hour 6 = 6 cycles/hour (Factory setting) 9 = 9 cycles/hour 12 = 12 cycles/hour Danfoss Heating 9

Option 35 - Set Integration Time (Option 34 set to 3, 6, 9 or 12) This adjusts the integration time of the PI algorithm to increase control accuracy. It is only active if Option 34 has been set to Chrono 3, 6, 9 or 12. It should only be adjusted after seeking advice from the manufacturer. Press + until Option 35 is displayed, use V or Λ to select required setting. (NB Seek advice prior to adjusting) 2.5 = Integration time set to 2.5% (Factory Setting) 5 = Integration time set to 5% 10 = Integration time set to 10% Option 36 - Set Temperature Override Rule This establishes the degree of temperature override available to the user. Press + until Option 36 is displayed, use V or Λ to select required setting. This option is not possible if the thermostat is set to STAT in Option 40. 0 = No limit (Factory Setting) 1 = Limited to ±2ºC (±3ºF) 2 = No override allowed Option 37 - Set Time Duration of Override Rule This establishes the duration of a temperature override available to the user. Press + until Option 37 is displayed, use V or Λ to select required setting. This option is not possible if the thermostat is set to STAT in Option 40 or Override Limit is disabled. 0 = Next Event (Factory Setting) 1 = 1 Hour 2 = 2 Hours 3 = 3 Hours 4 = 4 Hours 10 TP7001

Option 38 - Relay State on Low Battery Detect (Battery powered versions only) This establishes the position that the relay is driven to when the unit shuts down due to low battery state. Press + until Option 38 is displayed, use V or Λ to select required setting. This option is only possible on battery versions. 0 = Output OFF (Factory setting) 1 = Output ON Option 40 - Number of Events per Day This sets the thermostat to operate with either 2, 4 or 6 switching events per day or to run in stat mode. Press + until Option 40 is displayed, use V or Λ to select required setting. 1 = Stat (Manual operation - no programming function) 2 = 2 Events per day 4 = 4 Events per day 6 = 6 Events per day (Factory setting) Option 41 - Operating Mode (7 Day, 5/2 Day or 24 Hour) This sets the thermostat to operate using either 7 day, 5/2 day or 24 hour mode. Press + until Option 41 is displayed, use V or Λ to select required setting. This option is not possible if the thermostat is set to STAT in option 40. 7 = 7 Day (Factory Setting) 5-2 = 5+2 Day (or A-B if A days is set in option 1) 24 = 24 Hour Danfoss Heating 11

Option 70 - Keyboard Disable Rules This establishes the degree of functionality of the keyboard available to the user. It is only active if DIL switch 1 is set to disabled. Press + until Option 70 is displayed, use V or Λ to select required setting. 0 = Normal Lock - Programming Functions Locked (Factory Setting) 1 = Full Lock - All keys are disabled Option 71 - Random Start Rules (24V/230V versions only) This enables a random start on power-up following a power cut to reduce load on the electrical network. Random delay is in the range of 2-90 seconds. Press + until Option 71 is displayed, use V or Λ to select required setting. 0 = Disabled (Factory setting) 1 = Enabled Option 72 - Owner Site Reference Number This enables multi-site owners to store a site reference number in the thermostat. Press + until Option 72 is displayed, use V or Λ to select required setting. 00 (Factory setting) 01 to 99, with scroll over Option 73 - Owner Thermostat Reference Number This enables site owners to store a thermostat reference number in the thermostat. Press + until Option 73 is displayed, use V or Λ to select required setting. 000 (Factory setting) 001 to 999, with scroll over 12 TP7001

Option 74 - Date Format for Calendar Clock This allows date format to be chosen. Press + until Option 74 is displayed, use V or Λ to select required setting. 0 = European (dd/mm/yy) (Factory setting) 1 = American (mm/dd/yy) Option 75 LCD Switch Off This option allows the measured temperature part of the display to be disabled or all of the display to be switched off when not in use. Press + until Option 75 is displayed, use V or Λ to select required setting. 0 = Display off after 5 minutes 1 = Measured Temperature display disabled 2 = LCD always active (Factory setting) Option 80 - Enable / Disable + Hours Function Enables or disables the +Hours button. Press + until Option 80 is displayed, use V or Λ to select required setting. 0 = Disabled 1 = Enabled (Factory setting) Option 81 - Thermometer Calibration Bias This allows the thermostat calibration to be biased by up to ±1.5 C. Press + until Option 81 is displayed, use V or Λ to select required setting. Any value between -1.5ºC and 1.5ºC in 0.5ºC steps Factory setting is 0.0ºC Danfoss Heating 13

Option 90 - Define Remote Sensor Type (Remote sensor 1 - Backplate connection b) This allows type of remote sensor input type to be defined. Press + until Option 90 is displayed, use V or Λ to select required setting. 0 = No Sensor (Factory setting) 1 = Remote room or Duct sensor, internal sensor disabled 2 = Remote limit (floor) sensor, define setpoint in option 93 3 = Digital input for window, card reader, or teleswitch, define functionality in option 94 4 = Outdoor temperature sensor (information only - no control via sensor reading) Option 91 - Define Remote Sensor Type (Remote sensor 2 - Backplate connection C) This allows type of remote sensor input type to be defined. Press + until Option 91 is displayed, use V or Λ to select required setting. 0 = No Sensor (Factory setting) 1 = Remote room or Duct sensor, internal sensor disabled 2 = Remote limit (floor) sensor, define setpoint in option 93 3 = Digital input for window, card reader, or teleswitch, define functionality in option 94 4 = Outdoor temperature sensor (information only - no control via sensor reading) 14 TP7001

Option 92 - Define Remote Sensor Type (Remote sensor 3 - Backplate connection d) This allows type of remote sensor input type to be defined. Press + until Option 92 is displayed, use V or Λ to select required setting. 0 = No Sensor (Factory setting) 1 = Remote room or Duct sensor, internal sensor disabled 2 = Remote limit (floor) sensor, define setpoint in option 93 3 = Digital input for window, card reader, or teleswitch, define functionality in option 94 4 = Outdoor temperature sensor (information only - no control via sensor reading) Note: Only one of each type of sensor may be fitted - the choices within options 90-92 will automatically be limited once remote sensor types are chosen. Option 93 - Set Limit Sensor Set-Point (One of options 90-92 set to 2) This allows the thermostat limit sensor to be set, typical application is floor heating. Press + until Option 93 is displayed, use V or Λ to select required setting. If the temperature sensed by the limit sensor exceeds the limit setting the output will be turned off until the temperature has dropped by 2 C. F10 will flash in the display while the output is disabled. This option is only possible if one remote sensor option is set to Remote Limit (Floor) Sensor (Setting 2) Any value between 20.0ºC and 50.0ºC in 0.5.0ºC steps Factory setting is 27ºC The temperature set for the limit point sensor will be determined by the type of floor. The recommended limits are: Tiles on chipboard and wooden floors 27 C Carpet or vinyl on chipboard 35 C Tiles on concrete floor 40 C Concrete, screed, etc 45 C Danfoss Heating 15

Option 94 - Configure Digital Input Switch Type (One of options 90-92 set to 3) This allows the switch type of the digital input to be configured. Press + until Option 94 is displayed, use V or Λ to select required setting. This option is only possible if one remote sensor option is set to Digital Input (Setting 3) 0 = Contacts Normally Closed, open circuit contact to force unit into thermostat mode, short circuit contacts to return to normal operation. 1 = Contacts Normally Open, short circuit contacts to force unit into thermostat mode, open circuit contacts to return to normal operation (Factory setting) 16 TP7001

5.0 How to Reset the Unit 5.1 Partial reset Partial reset is used if the display freezes for any reason. 1. Press and release the RESET button. This does not reset any programmes or the time or date. It will simply restore operation in the unlikely event the unit has become unresponsive. 5.2 User full reset 1. Hold down the PROG button 2. Press and release the RESET button This resets event times and any User Advanced Programme settings, but does not reset time or date. 5.3 Installer full reset 1. Press and hold V and PROG for approx. 3 seconds to enter User Advanced Programming 2. Press and hold V, Λ and PROG for approx. 5 seconds to enter Installer Advanced Programming 3. Hold down the PROG button 4. Press and release the RESET button This resets event times and all User and Installer Advanced Programming settings and returns them to factory settings, however, time, date and service due date are not reset. Danfoss Heating 17

18 TP7001

Danfoss Heating 19

Danfoss Ltd. Ampthill Road Bedford MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk Part No. 37034v02 11/12