HMP FULLY AUTOMATIC HEAT TREATMENT CONSOLE

Similar documents
PCR AUTOMATIC HEAT TREATMENT CONSOLE

Engineered to meet your needs T he oldest name in stud welding,

multi-function meters

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

AHP-1200CPV Cold/Warm Plate Product Manual Volume 1.3

Modular Lube Lubrication Systems System Controls

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

TeSys circuit-breakers

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

DCP100 Digital Control Programmer Specifications

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Operating Instructions

INSTALLATION & USER GUIDE

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

GV2ME. Main. Device short name. Device application

Model KT 53 Cooling incubators with thermoelectric cooling

Automatic Transfer Switch Control PLC Operator s Manual

Model IQ4-PC User Manual Revision Date:

ULTRALOW TEMPERATURE FREEZERS -86 C

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS

BE3-GPR GENERATOR PROTECTIVE RELAY

OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Sample BD Tech Concepts LLC

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2P05. Main. Device short name. Device application

INSTALLATION INSTRUCTIONS FOR

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO NOTE

Model KT 115 Cooling incubators with thermoelectric cooling

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

WELDING CONTROL UNIT: TE 450 USER MANUAL

AC1036. Definite Purpose Contactors

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Blown Film Extrusion. Line Control. 5 Layers CD Series IBC Temperature USER MANUAL

Certificate of Calibration

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

Sprite TL Quick Start Guide

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Operating instructions Electronic preset counter Type series 717

Single Axis Position Controller

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME. Main. Device short name. Device application

Sample BD Tech Concepts LLC

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

263 Series LED Bargraph Indicator and Controllers

Part-Turn Electric Multi-Turn Electric

SCALE & WEIGHT DISPLAYS

MS2540 Current Loop Receiver with RS485 Communication

Junior Max (JR Max ) Controller

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

ICS Digital Menu. Installation Guide Version 1.1

MON3-2W/HR MON4-2W/HR (Document P/N Rev-B)

SAPLING WIRED SYSTEM

Technical data. General specifications. Indicators/operating means

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

AS09..S 3-pole Contactors - Spring Terminals

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Panel-Mounted Thermostat

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

User Manual Power and Harmonics Analyzer Model PQ3350

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

Series CT7N Bimetallic Overload Relays

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Hotplate/Stirrers. Performance, Selection, Control

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

EDL8 Race Dash Manual Engine Management Systems

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Installation and Operation Manual. YMP Series Signal Programmer

Active UTP Transceiver Hub Installation Guide

2002 Martin Professional A/S, Denmark.

Model KT 170 Cooling incubators with thermoelectric cooling

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

Installation Instructions

VAT 20 Adjustable Frequency Drive

Standard signal metering in wall-mounting case

Three Phase - General Purpose. THREE PHASE: 3 kva - 9 kva Epoxy Encapsulated Series 76 ISO-Shield

Transcription:

Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: www.maritimestress.com E-mail: info@maritimestress.com OPERATION MANUAL HMP2008-6 FULLY AUTOMATIC HEAT TREATMENT CONSOLE

HMP2008-6 Fully Automatic Six Way Heat Treatment Console: 2 DESCRIPTION: The HMP2008 fully Automatic touch screen heat treatment console is designed to control various heat treatment processes by closely monitoring and adjusting the set point temperature and the ramp rate. It incorporates the latest microprocessor based technology and is simple to set up and operate. Each zone can be used in the fully automatic mode (individually or the channels can be slaved to the previous programmed channel i.e. Channel 1 set as programmer, Channels 2-6 set as slave). It incorporates the latest microprocessor based technology and is simple to set up and operate. The heatmanager pro touch screen system has a built in paperless recorder and built in data logger with export to excel using a USB stick. Control setting is by means of touch screen and an LCD screen provides visual indication of program position and output status at any time. The HMP2008-6 is equipped with a digital amp meter and a 6 position switch, which is the utmost importance for checking the current to the ceramic pad heaters to make sure they are all operating. SPECIFICATIONS HMP2008-6 Fully Automatic Touch Screen Six Way Heat Treatment Console: Length: 33 Width: 26.5 Height: 35 Weight: Approx. 892lbs Material: 12 gauge stainless steel cabinet Wheels: 900 lbs capacity each with brake (4) (or SS mounting brackets available upon request) Handling: Two heavy duty top lifting eye lugs and forklift access. Inputs: Voltage: Current: Power: Frequency: 380-415-440-480-575, 3 Phase 100 amp or optional 125 amps for 380/415 VAC 75 KVA Isolated Copper Wound 60 Hz / 50 Hz Output Per Zone: Zones: 6 Voltage: 65 or 85 VAC, single phase Current: 192 amps @ 65 V or 156 amps 85V Power: 12.5 KVA Activation: 200 amp contactor Control per zone: Digital temperature controller Control Circuit: HMP2008-6 Fully Automatic Heat Treatment Console REV 0, 01/08 www.maritimestress.com

3 Voltage: Current: Power: Auxiliary: 110 VAC, single phase 5 amp circuit breaker 1.2 KVA winding on power transformer 110 VAC supply, single phase 6 Channel Temperature Programmer/slave function: TOUCH SCREEN: Temperature Range: Thermocouple: 4 LCD Color 0-2200 F Type K Digital Amp Meter: Primary Amperage: Secondary Amperage: Up to 200 amps 5 amps Protection: 120-VAC Control Circuit: 5 amp circuit breaker Heater Power: Isolation contactor for each zone Console Power: 100 amp main circuit breaker Power Transformer: 392 F (200 C) over temperature thermostat per phase Cooling fan: 340 CFM - Thermally protected HMP2008-6 Fully Automatic Heat Treatment Console REV 0, 01/08 www.maritimestress.com

Maintenance Requirements: 4 Inspection and Cleaning: ITEM INSPECTION FREQUENCY ACTION Contactors Burned or Pitted Every 6 months Clean or replace contacts Heatmanger pro/programmer Calibration Every 12 months Check accuracy and adjust if required System Cleanliness Every 6 months Vacuum with power disconnected System Electrical Loose connections Every 6 months Tighten all terminal connections Air Vents and fan Dust or dirt build up Every 3 months Clean with vacuum with power disconnected Check bolts and screws Loose Every 6 months Tighten HMP2008-6 Fully Automatic Heat Treatment Console REV 0, 01/08 www.maritimestress.com

HMP2008-6 Fully Automatic Six Way Heat Treatment Console Operating Instructions: 5 1. Switch 100 amp main circuit breaker to the ON position. 2. Make sure zones used are indicating the actual temperature on the heatmanager pro prior to start and then turn rocker switches to the ON position which are in use. 3. Decide on the heat treatment specification and set as follows: HMP2008-6 Fully Automatic Heat Treatment Console REV 0, 01/08 www.maritimestress.com

HeatManager Pro USER MANUAL REV. 1.1 6, 8 OR 12 PROGRAMMERS / CONTROLLERS 6, 8 OR 12 TC INPUTS 1) Introduction 2) Main Menu a) Lock function 3) Profile Settings a) Step,Target Temp, Ramp, Soak and Link settings b) Programmer, Slave and Unused selection 4) Operation Mode a) Operation RUN/STOP screen b) Output monitoring screen c) Programm changing while running d) All channels Trend screen e) Detail channel screens f) Step function g) Programm Hold h) Calibration screen i) PID setting screen j) Programmer trend screen 5) Basic Settings a) Auto Hold Settings b) Hot/Cold start selection c) Language selection d) Date and time settings e) Copy data 6) Other Settings a) Brightness setting b) TC reverse detection 6, 8 OR 12 TC OUTPUTS 1) Introduction First of all, we like to thank you for purchasing our HeatManagerPro. We are confident it will meet 100% of your needs for Heat Treatment Applications. The HeatManagerPro is a state of the art controller for Heat Treatment Applications and combines user friendly operation with the newest technology. The heart of the HeatManagerPro is the Full color TFT touch-screen from which you can set-up and run your system. The control is done by a dedicated rack-mounting system that is located inside the cabinet. The HeatManagerPro is availlable as a 6-loop, 8-loop and 12-loop system. Basic features: Color TFT touch-screen 6, 8 or 12 loop controller Free selectable programmer/slave combinations Up to 8 ramp/soaks per programm Auto Hold and Manual Hold function Step function Both C and F available TC break and reverse detection Calibration function Realtime trend-charts (paperless recorder) Output status monitor Lock function against unauthorized operation Datalogging function with export to excel

2) Main Menu When you power-up the system, the general Information screen with company information of your supplier will be shown automatically. To exit this introduction screen, just touch the screen and you will swap to the Main Menu. On the Main Menu, you can select to go to the Operation mode, the Profile setting mode or the Basic setting mode, by pushing the corresponding button. Push the GENERAL INFORMATION button to go back to the introduction screen. 2 a) Lock function From the main menu, the operator can lock the complete system to prevent unauthorized operation by pushing the left down side corner for about 5 seconds. By pushing this touch-area, the system will automatically swap to the operation locked screen, where the start/stop buttons are disabled. To return from the operation locked screen, push again the left down side corner for about 5 seconds. In Lock mode, the operator still has the possibility to swap to the all channels trend, by pushing the button TREND. Touching the trend screen just anywhere, returns you to the RUN/STOP LOCK screen. 3) Profile settings a) Push the PROGRAMM SETTINGS button to swap to the Profile Setting menu, where you can start setting the profile of channel number 1. *Note that for all channels except channel 1, the operator can select whether that channel is a programmer, a slave (of the previous programmer) or unused. Due to this possibility, the system can have one programmer with all other channels set as slaves, all channels set as individual programmers or just every combination in between. **Note that once you have entered the PROGRAMM SETTING mode, you have to go through all the channels to get back in the MAIN MENU. On the profile setting screen, there are four parameters that can be set for each segment. First select the segment you want to set by touching the segment number. The keypad will pop-up and you can select the segment you want to programm, from segment 1 to segment 8. Always start your programm in segment number one! Next, programm the target setpoint for that segment, the ramp to setpoint in deg. per hour and the dwell time in minutes. Use the small dwell time help to calculate your minutes and save them in the dwell time by pushing the copy to dwell time button. Max. is 99 hours and 59 minutes. Remember to do so for each segment! After setting the temperatures and times for the first segment, you have to set the link-segment. This is the segment where the programm jumps to, after the current segment has elapsed. Setting range is 0 to 8, where 0 means no jump to another segment. After setting the first segment, increase the segmentnumber and repeat setting the values for that segment. Due to that procedure, you can create a programm of max. 8 ramps and 8 soaks that ends at the last segment (number 8), or that keeps on repeating by setting the link-segment at 1 in the last segment. Of course, it is also possible to repeat a part of the programm by setting the link segment at X (for example 4) in segment 8. Segment 4 till 8 will then be repeated till the operator pushes the stop button. After you have set your programm, push the NEXT CHANNEL button to swap to the next channel selection page. Top of document 2

b) On the Channel selection screen you can select each channel to be programmer, slave of the previous programmer or unused, by pushing the corresponding button. You can go back to the previous channel at any time, by pushing BACK button. Also, if you have selected that channel to be a slave, you can set a setpoint offset compared to the setpoint of the previous channel. After setting the channel function, push NEXT. If you choose PROGRAMMER, you will automatically swap to the channel 2 profile setting screen. If you have selected UNUSED or SLAVE, you will swap to the next channel selection screen. From here, you repeate the same procedure to set all channels. After you have set all channels to be a programmer, slave or unused you will enter the End Programmsetting page that confirms that all channels have been set. Also, if you are not sure you did set all channels in a proper way, you can go back to the previous channel by pushing the BACK button. Push NEXT to swap to the MAIN MENU 4) Operation Mode Push the OPERATION button to swap to the Operation Mode, where you can RUN and STOP your programmers by pushing the corresponding channel number button. For each channel, the P, the S or the U indicates wether that channel is a Programmer, a Slave or Unused. Programmers can easily be recognized by the blue rectangle surrounding the channelnumber. a) To RUN or STOP a programm, toggle the the corresponding programmer channel button for one second. The one second delay on these buttons is to prevent the operator for running and stopping channels by incident. The slaves belonging to that programmer will automatically follow. In the STATUS column, you can see for each channel if it is in RUN or STOP mode. In the OUT (OUTPUT) column you can see which outputs are active. In the HOLD column you can see on the word ON if that programmer is in Hold. ON will only be displayed on the programmers. On the yellow leds in the HOLD column, you can see which channel(s) are responsible for the programmer s hold. This can be the programmer itself, any of its slaves, or any combination. b) If you touch the OUTPUTMONITOR button on the operation RUN/STOP screen, you will swap to the output monitor screen, where you can view the output percentage per channel and also the TC break indicator. Both screens look quite similar, however the function of the channel number buttons (CH1 ~ CH6) has changed. *Note that if a TC break appears while in RUN mode, the HeatManagerPro will automatically swap to the OUTPUTMONITOR screen. c) On the OUTPUTMONITOR screen you can use the CH1 ~ CH6 buttons to enter the profile setting mode for the programmer channels. Slave and unused channels will be ignored. Also note that this is only possible when the programmer is not in Hold status. After pushing the channel number button of a programmer that is not in Hold, you swap to the corresponding setting screen, even when that channel is in RUN mode. You are now able to change the running step, or one of the other steps, in the same way as described in chapter 3a. Pushing the Back button will bring you back to the OUTPUTMONITOR screen. Pushing the OPERATION button on the output monitoring screen will bring you back to the operation RUN / STOP screen. Top of document 3

d) Touch the TREND button on both the RUN/STOP or OUTPUTMONITOR screen to swap to the all channels trend screen where you can view all 6 Process values at the same time over the last 6 hours. In case of the 8 and 12 loop system, push the same TREND button on the corresponding channel screen. Touching the trend screen just anywhere will return the operator to the previous screen. e) To swap to the DETAIL CHANNEL SCREEN, you have to touch the blue rectangled programm channelnumber. This means you can see the detail information of all different programmers by touching the corresponding channel. On the DETAIL CHANNEL SCREEN you can find usefull information about the programmer status. Push the BACK button to return to the Operation RUN/STOP or OUTPUTMONITOR screen. f) Push the NEXT SEGMENT button to activate the step function. The running programm will skip directly to the next segment. Remember that each segment exists of one ramp and one soak. So, if you push the NEXT SEGMENT button, you will directly jump to the start of the next ramp. *Note: Step function will only work when the programmer is not in Hold. **Note: The elapsed soak time will reset when changing from ramp to soak state. This means that if you STEP while a soak is running, and jump to the start of a new ramp, the elapsed soaktime of the previous step will be shown until the ramped setpoint has reached the target setpoint of that step and start soaking. g) Push the programm Hold button to activate the Hold function manually. Pushing the button again will release the manual Hold function. h) Push the CALIBRATE button to swap to the calibration screen. On the calibration screen the operator can add or substract some degrees of the process values to calibrate the controller with your paper trend chartrecorder. Touch the number to set the value by the pop-up keypad. Touch the up and down keys to directly add or substract one. Push the reset screen to zero the applicable channels. Push BACK to return to the detail channel page. Password protection: As the CALIBRATION and PID SETTINGS screens are password protected, type USER in CAPITAL letters to enter these screens. After 1 minute not touching the screen, the password is timed-out and the operator has to type USER again if he wants to enter again or leave the calibration screen. i) Push the PID SETTINGS button to enter the PID settings menu, where you can edit the PID settings. Please note that the factory settings are carefully choosen for this application and will work well in most situations. *Note that you can set different PID settings for each segment of each channel. By touching the segmentnumber, a small touch-pad will pop-up to change the segment. After you have changed the segment, you can edit the PID valued for that segment using the same pop-up touchpad. Push Back to return to the previous screen. Top of document 4

j) Push the TREND CH button to swap to the trend screen of the corresponding programmer. On this screen the operator can view the elapsed setpoint and the process value trend. Push anywhere on the screen to return to the previous screen. 5) Basic settings Touch the BASIC SETTINGS button on the Main Menu screen to swap to the BASIC SETTINGS screen. As the basic settings are Password protected, you have to type-in the word MASTER in CAPITAL letters, to enter the BASIC SETTINGS mode. Please note that the BASIC SETTINGS mode is only mentioned for skilled personnel. As the BASIC SETTINGS do have serious influence on the control of the unit, all channels have to be in STOP mode. If one or more channels are still in RUN mode when you try to enter the BASIC SETTINGS mode, you will get an ATTENTION screen. Push BACK to return to the MAIN MENU and go back to the Operation RUN/STOP screen to STOP all channels, before you can enter the BASIC SETTINGS mode. After you have entered the BASIC SETTINGS mode you can select if you want to change the hold settings, the hot/cold start selection and the desired Language. Also you can set the correct date and time, needed for correct datalogging of your process values. With the copy data function you can copy the logged data onto you memory-stick. a) Push the HOLD SETTINGS button to enter the Hold setting menu, where you can switch between used and unused by pushing the corresponding button. A small pop-up touchpad will allow the operator to set the correct value between 3 and 100. Factory settings for the HOLD function is OFF and a deviation value of 100 degrees. Push BACK to return to the Basic Setting menu. b) At the HOT/COLD START SELECTION page, you can select the mode after power failure. When you want to return in RUN mode after powerfalure, please select HOT START. When you want to return in STOP mode after powerfalure, please select COLD START. Push BACK to return to the BASIC SETTINGS menu. Top of document 5

c) On the LANGUAGE SELECTION page you can switch between English, German and Nederlands (Dutch). In the future there will also be other languages availlable. d) On the DATE AND TIME SETTINGS page you can set the correct date and time that will be used in the automatic datalogging feature. This will make sure that the correct date and times are used in the.csv file that you can create on the COPY DATA page. The blue numbers are the current settings, the white settings are the new settings. Just touch the white numbers, and type in the desired date and time. The new values are active inmediately. e) Push the COPY DATA button to enter the COPY DATA screen. A batchnumber can be set, that will be used as a filenumber when copying the data to your USB stick. Of course, make sure your USB stick is connected. After copying the.csv file to your USB stick by just pushing the COPY DATA TO USB button, you can delete the logfile by pushing the DELETE DATA button for 3 seconds. By this action, the Batchnumber will be reset also and the ALL CHANNELS trend will be cleared as well! The individual channel trends must be cleared by hand. Return to the MAIN MENU by pushing the corresponding button at the leftside. 6) Other settings Brightness Brightness can be set by toggeling the two top corners of the touch area. At the bottom, an eight step selection box is shown where you can select the brightness you like. After you selected the right brightness, just touch the X button and the selection box will disapear. TC reverse connection When the operator has connected the thermocouple wrong by changing the plus and minus, the temperature on the display will decrease while the real temperature will increase due to the output power of the heating elements. When the system measures a temperature of 50 degrees (the real temp is 90 degrees), the operator will see a warning message on the screen. Touching this screen will return the operator to the operation RUN/STOP screen where the operator can see which channel is connected wrongly. Top of document 6

HMP2008-6 Fully Automatic 6 Way Heat Treatment Console System Connections: 6 Thermocouple Cable 1 2 3 4 5 6 Secondary Cable 3 way splitter 3 way splitter Note: The HMP2008-6 connections for circuit number 6 shown. Circuit numbers 1, 2, 3, 4, & 5 should be connected in the same manner CP10 CP10 Parallel connection of heaters Thermocouple Wire CP10 HMP2008-6 Fully Automatic Heat Treatment Console REV 0, 01/08 www.maritimestress.com

TO CHANGE SECONDARY AND PRIMARY CONNECTIONS FOLLOWS THESE INSTRUCTIONS: 7 1. Switch off main breaker and disconnect primary power cable supply. 2. Loosen the primary power cable clamp. 3. Remove panel labelled Back Panel to change secondary and primary connections. 4. Change connections as per requirements and make sure the connections are tight. 5. Make sure nothing is left inside the enclosure. 6. Put the Back Panel back on. 7. Tighten the primary power cable clamp. 8. Hook up primary power cable supply and then switch on main breaker when ready. 75 KVA/60 KW 0 VAC 0 VAC 0 VAC 65 VAC 65 VAC 65 VAC Primary 380/415/440/480/575, 3 Phase 85 VAC 85 VAC 85 VAC Secondary 0/65/85, Single Phase 575 VAC 575 VAC 575 VAC (1 P.H.) 110 volt @ 1200 VA, Single Phase 480 VAC 480 VAC 440 VAC 380 VAC 440 VAC 380 VAC 415 VAC 415 VAC 480 VAC 440 VAC 380 VAC 415 VAC Isolation Copper wound Over temperature thermostat per phase Transformer: Weight: 660 lbs (approx.) Dimensions: 24 L x 17 W x 21 H Features: All connections in back for easy access. Class 220 insulation. 150 degrees C. temperature rise. CSA certified. UL listed. Manufactured to ISO9001 quality certification. ORDERING INFORMATION: MSPART# - 75KVA #7-3 phase isolated copper wound power transformer. Primary 380/415/440/480/575, 50/60 Hz secondary 0/65/85 (Thermal trips per phase to prevent overload). PRIMARY VOLTAGE CHANGING TAPPINGS: CURRENT 18 x 80V Heaters CONNECTION 575 VAC 76 amps 1-1-1 480 VAC 91 amps 2-2-2 440 VAC 99 amps 3-3-3 415 VAC 105 amps 4-4-4 380 VAC 114 amps 5-5-5 SECONDARY CURRENT CONNECTION VOLTAGE 65 volts 384 amps per phase 65-65-65 as marked 85 volts 312 amps per phase 85-85-85 as marked **NOTE: Optional 125 amp circuit breaker required for 380VAC/415 Primary Voltage HMP2008-6 Fully Automatic Heat Treatment Console REV 0, 01/08 www.maritimestress.com

SPARE PARTS FOR HMP2008-6 HEAT TREATMENT CONSOLE 8 MS Part No. 900Wheel Heatmanagerpro 75KVA #7 Amp Meter Selector Switch CT A10 PP-20-KX A37-EL A38 46F4171 Merlin 100 amp Merlin 125 amp 56F874 56F876 F-A18 Fan Description Of Part Wheel Swivel Caster (900 lb Capacity with brake) Heatmangerpro 75 KVA - 3 Phase Isolated copper wound power transformer: Primary 380/415/440/480/575, 50/60 Hz Secondary 0/65/85 (Thermal trips per phase to prevent overload) Digital Amp Meter 0-200 amps Six Channel Selector Switch with Plate & Knob Current Transformer 0-200 amps 300 amp Female Panel Mount Socket Complete Thermocouple Extension Cable 200 amp contactor (100% Duty Cycle) 110 Volt Neon ON/OFF Rocker Switch 100 amp - 3 phase Circuit Breaker with 120 volt uv Release Optional for 380/415: 125 amp - 3 phase Circuit Breaker with 120 volt uv Release 5 amp Circuit Breaker 10 amp Circuit Breaker Female Thermocouple Panel Mount (Type K ) 340 CFM Cooling Fan 120 V 120 VAC Ground Fault Receptacle 96F4496 3 Pole Terminal Block #1 Tinned #1 Tinned Cable with lugs (please specify length) #4 Tinned #4 Tinned Cable with lugs (please specify length) 90F7177 AL1/4 Lug 1/0-3/8 Hole Aluminium Lugs 1/4" Hole HMP2008-6 Fully Automatic Heat Treatment Console REV 0, 01/08 www.maritimestress.com