Index. English. English User Manual Eco.X

Similar documents
Cronotermostato Digitale

Chronothermostat IRIDE. User Manual

Radio Thermostat Clock

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Instruction Manual for Programmable Digital Timer

Style 5S Clock / Timer

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

APOLO DC B Electric Thermal Radiators

Programmable Room Thermostat With RF

EN Wireless programmable thermostat

DLP200M 2 Relay Module for Heating and Cooling Plants

16 Amp Electronic 24 Hour/7 Day Time Controller

SAUTER flexotron RDT405 Manual

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Pulse Counters, electronic

Actuators IC 20, IC 40

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

Operating instructions. Universal timer switch display

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Digital Time Switch. Installation & Operating Instructions

Operating Manual. Basic Control BC16. two-channel for eco moon

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

Sequential and Combination Timer TK-415 with RS-232 communication

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Turnout Decoder TD Maxi. User Manual - version 0.1.6

Luminaire installation box Surface-mounted box Ceiling installation box

Battery Operated Controllers

7 Day Digital Time Switch

MULTIS L72. Operating instructions

SOFT LED 4 Vari-White INSTRUCTION MANUAL

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

SH2RE16A4. Output relay module. Benefits. Description

REGO Start&Go USER MANUAL

Art Stand-alone proximity reader

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

Capacitance Limit Detection nivotester FTC 420/421/422

XTM72E & F Real-Time Clock Modules

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

Professional-Practice

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Automatic Transfer Switch Control PLC Operator s Manual

Assembly. Front view. LEDs. Parametrization interface. Power Bus

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

aquauno INSTRUCTIONS WATER TIMER VIDEO VIDEO

Ultra flat Pool & Spa LED light OWNER S MANUAL. Ultra flat shape 2 wire 12VAC ON/OFF control NoAir PAR56 Retrofit

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Sensopress LCD Special English

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

CountDown Touch User Manual

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

FIELD MOUNTED RATE TOTALISER MODEL 202D

Ducasa Digital Programmer

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Litile34 OPERATION MANUAL

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

Ultra thin LED lamp for Pool & Spa OWNER S MANUAL

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Art M Digital codelock module

Programmable time switches Multiple function - daily/weekly

28 4K LED monitor. User Manual M284K

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

02/11/2015

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Operating instructions III / 2004

Operating instructions - High Performance LED Timer / / /

Converts any TV to Digital. MFR-300 User Guide

E3/DS3 Fibre Extender

Operating instructions

Operation Guide 6022 ENGLISH

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

CONTROL UNIT BIOS1 HR Programmable Control board for sliding gates

7 Day Digital Programmer

TDDFM14 OWNER S MANUAL

Single cable multiswich programmer PC102W

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

LCD VALUE SERIES (32 inches)

LW10-T600. P10 Led Wall Display

Installation and Operation Manual Next Generation On-Camera Prompter Displays

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

MICROMASTER Encoder Module

Weighing Scale. 10key&12key User manual

XTM72 Exerciser Timer Module

Operating instructions Electronic preset counter Type series 717

USER MANUAL. EMF Meter. Model EMF510. Additional User Manual Translations available at

12.1 Inch CGA EGA VGA SVGA LCD Panel - ID #492

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Multifunction Digital Timer

Gamma instabus. Technical product information

Standard RS232 RS ma

Transcription:

Index Safety Warnings Page 18 Technical Specifications Page 18 Display and Programming Page 19 Initial start up / Reset Page 21 Clock Setting Page 22 Language Selection Page 22 Automatic Operation Page 23 Programme Setting Page 24 Temperatures Setting Page 25 Manual Operation Page 26 Replacing the Batteries Page 28 Reference Standards Page 29 Dimensions Page 30 Mounting Page 31 Connection diagram Page 32-17 -

SAFETY WARNINGS During the installation and operation of the instrument, follow the instructions below: 1) The instrument should be installed by qualified personnel 2) Before gaining access to the connection terminals make sure that the conductors to be connected to the instrument or already connected are not live 3) Do not power or connect the instrument if any part of it is damaged 4) Follow the connection diagrams in this manual and on the instrument TECHNICAL SPECIFICATIONS Daily (Eco.X-D) or weekly (Eco.X-W) programming versions Power supply: 2x1,5 V micro stylus alkaline batteries (AAA) Autonomy: 12 months minimum (with alkaline batteries 1100 ma/h at 23 C) Charge reserve: about 2 minutes for batteries replacement Battery charge condition indication with failed batteries signalling Output: bistable relay with max. 8(5)A (250V AC) exchange contact 2 temperatures, SUN and MOON, are settable by means of a trimmer: - SUN : +2 C +30 C comfort temperature regulation - MOON : +2 C +22 C saving temperature regulation ON/OFF temperature regulation with fixed differential of 0,3 C Clock: weekly/daily Eco.X-W: language selection for the display of the day of the week chosen between: Italian,, French, German, Spanish Programming resolution: 1h Temperature measured resolution: 0,1 C Precision: ±0,5 C Temperature measurement update every 60s Temperature measured: 0 C +40 C Operating temperature: 0 C +50 C Temperature regulation field: +2 C +30 C Storage temperature: -10 C +65 C LCD display with visualization of temperature, time, daily programme and relay activation state and day of the week (in Eco.X-W only) Protection level: IP40 Test on each device - 18 -

Eco.X digital chronothermostat Code Model Description VN161600 Eco.X-D Weekly chronothermostat White VN160800 Eco.X-W Daily chronothermostat White VN975900 Cover Aluminium-raider CR Cover for Eco.X chronothermostat VN976700 Cover Grigio-iron AC Cover for Eco.X chronothermostat VN977500 Cover Nero-lux NR Cover for Eco.X chronothermostat VN978300 Cover Blu-lagon BJ Cover for Eco.X chronothermostat VN979100 Cover Metallic GF Cover for Eco.X chronothermostat DISPLAY AND PROGRAMMING LCD DISPLAY KEYS AND HANDLES The LCD display shows the following information: 1 2 3 5 4 SUN / MOON time programming with 24 SUN symbols and 24 MOON symbols related to 0 23 time. DAY (weekly version only) day of the week in 5 languages selected by the user. TIME shows the time (HH:MM). TEMPERATURE shows the temperature (in C). FIRE shows the relay activation - 19 -

KEYS AND HANDLES D H M R O K D H M R (Reset) OK day of the week setting (in the weekly version only) increases the hour field increases the minutes field resets the functions to the default values programming, language selection, exit to normal operating mode SUN comfort temperature indication; during programming it sets the comfort temperature MOON saving temperature indication; during programming it sets the saving temperature SUN HANDLE comfort temperature regulation MOON HANDLE saving temperature regulation Hold down the keys to activate their respective operations. During the programme or language setting, if no key is pressed for 30s, the chronothermostat returns to normal operating mode and memorizes the modified operations. By pressing H or M, the value in the field to be modified increases with constant acceleration. - 20 -

INITIAL START UP / RESET Insert the batteries and press R (Reset) with a pencil or a pointed object. This operation will reset all the data and programmes previously set, which will be initialised as default. For all the days of the week this condition will set the following data: SUN comfort temperature from 07:00 to 21:59 MOON saving temperature from 22:00 to 06:59 M Reset R O K 3s All the segments of the display will be switched on and the relay will be activated for about 3s. The display will be switched off, the clock will restart from 00:00 on Monday (in Eco.X-W version only). Until the first clock set the display shows the ambient temperature and the time (flashing). Regulation begins only after the time setting. - 21 -

CLOCK SETTING Press D, H and M to set respectively the day (in Eco.X-W version only), the hour and the current minutes. Press one of these keys to increase their respective value of one ( H and M have the autorepeat function). Once the clock has been set, the chronothermostat moves to the automatic operation. D H M R O K Note: at any time it is possible to change the current day and time by pressing D, H and M and following the above mentioned instructions. LANGUAGE SELECTION AVAILABLE IN CHRONOTHERMOSTAT Eco.X-W ONLY Press OK for at least 3 seconds to modify the language display of the day of the week R 3sOK D H M - 22 -

The available languages are (in order): Italian (ita) (eng) French (fra) German (deu) Spanish (esp) Press D, H or M to select the language It is possible to abandon the selection by pressing OK or after 30s from the last key pression AUTOMATIC OPERATION In automatic operation the temperature regulation is active and the LCD display shows the following information: Current time (HH:MM) Temperature measured Temperature unit of measure ( C) FIRE symbol (if the relay is ON) SUN or MOON for each time of the day as per current daily programme Day of the week in the selected language (in Eco.X-W version) - 23 -

PROGRAMME SETTING Once the device is operating, the chronothermostat is set with the default programme ( SUN from 07:00 to 21:59 and MOON from 22:00 to 06:59) Press OK to modify this programme R O K D H M The display shows the word SET instead of the temperature, TIME field shows the current time (without minutes), the SUN / MOON symbol, relating to the displayed time, flashes and DAY field shows the day of the current week (weekly version only) Press or to set, for the time displayed, respectively the comfort or saving temperature (see paragraph TEMPERATURES SETTING ). Once the programme has been set, it is possible to move to the next hour and update the HOUR field (the flashing graphic field will step up clockwise). To modify the programme of a particular hour, press H till reaching the chosen hour (each time the key is pressed time increases of an hour without modifying the programme; the autorepeat function is active) then press or to set the temperature desired - 24 -

In Eco.X-W model only: press D to change the day of the week; each time this key is pressed the day increases of one. Press OK to return to the automatic operation If no key is pressed for 30s, the chronothermostat will abandon the programming function and memorize the modified settings Note: During the programme setting, regulation and relay operation are suspended TEMPERATURES SETTING Comfort (SUN) and saving (MOON) temperatures are set by means of two 3/4 turn handles. Press or in TEMPERATURE field to display the temperature (flashing) set by means of the respective handle; in the " DAY field the word SET is displayed Rotate the respective handle to modify the temperature. The temperature stops flashing for about 2s 10 5 15 20 25 30-25 -

Press or a second time to return to the display of the temperature measured It is possible to return to the automatic operation by pressing OK too It is also possible to modify the "SUN"/"MOON" temperatures without pressing the respective keys, operating just the handles. In this case the set temperature is not displayed Note: If no key is pressed or if the handle is not operated for about 30s, the chronothermostat will return to the automatic operation and memorize the modified settings MANUAL OPERATION Press or for at least 3s to move from automatic to manual operation. In manual operation the regulation temperature is prefixed in SUN or MOON for each time of the day. The operation type is indicated by the word MAN in DAY field and by all the suns and moons switched on. Press or to modify the regulation temperature. 3s 3s - 26 -

In DAY field the word SET is shown and the temperature begins to flash. To change the temperature operate the respective handle (as in the automatic operation). Temperature can be modified without pressing one of the or keys too. In this case the set temperature is not displayed. During the setting it is possible to move from SUN temperature to the MOON one and vice versa by pressing the respective key. Press or or OK again to move back to the manual operation. 30s after the last regulation the chronothermostat automatically returns to the manual operation. In MANUAL operation it is possible to modify hours and minutes, display SUN and MOON temperatures. On the contrary, it is not possible to modify neither the set programmes nor the selected language (in Eco.X-W). If the day of the week is modified (in Eco.X-W version only) you move back to the AUTOMATIC operation. Press or for at least 3s to move back to the automatic operation. - 27 -

REPLACING THE BATTERIES When the batteries are close to exhaustion, the display will flash and show the word BAT in DAY field (both in Eco.X-D and in Eco.X-W). The chronothermostat operates regularly, regulation included When batteries are removed, the display switches off and all the functions are interrupted, except for the clock update, until the nex batteries are inserted + + D H M R O K The maximum battery replacement time is about 2 minutes When the new batteries are inserted the chronothermostat immediately restarts. In case this does not happen press the Reset R key. - 28 -

REFERENCE STANDARDS Conformity to the EU directives: 73/23/CEE, modified by 93/68/CEE (low voltage) 89/336/CEE, modified by 92/31/CEE and 93/68/EEC (EMC) is declared with reference to the following standards: SAFETY EN 60730-2-9: Automatic electric command devices for household and similar use. Part 2: particular provisions for thermosensitive command devices. EN 60730-2-7: Automatic electric command devices for household and similar use. Part 2: particular provisions for timers. ELECTROMAGNETIC COMPATIBILITY EN 55014-1: General regulation on the immunity in household, commercial and light industrial environments. Electromagnetic compatibility Provisions for electrical appliances and tools and similar. Part 1: Emission. EN 55014-2: Electromagnetic compatibility Provisions for electrical appliances and tools and similar. Part 2: Immunity. - 29 -

DIMENSIONS 18 21 24 3 6 15 10 20 25 5 30 10 5 15 20 22 91 15 9 12 115 91 29 104-30 -

MOUNTING 21 24 3 15 10 20 10 15 18 6 5 25 30 5 20 22 15 12 9-31 -

- 32 -