MAKING MODERN LIVING POSSIBLE. TS715Si Electronic Single Channel Timeswitch with Service Interval Timer. Installation Guide.

Similar documents
TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

7 Day Digital Programmer 3 Channel Surface Mount

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

7 Day Digital Programmer

16 Amp Electronic 24 Hour/7 Day Time Controller

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

7 Day Digital Light Switch with Optional Dusk Start

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Digital Time Switch. Installation & Operating Instructions

7 Day Digital Time Switch

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

TDDFM14 OWNER S MANUAL

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

XTM72 Exerciser Timer Module

ZoneTouch V2 Zone Control System User Manual

Radio Thermostat Clock

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

2 Hour Electronic Boost Timer

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Aspect 2 Circuit Digital Scene Control

Installation and Operation Manual. YMP Series Signal Programmer

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Digital Economy Seven Programmer

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

Operating Instructions Dimmer for V Incandescent Lamps

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

.Power Distribution Center. PD-1. Instruction Manual

XTM72E & F Real-Time Clock Modules

WiFi Controlled Fused Spur Time Switch

INSTALLATION, PROGRAMMING AND OPERATION MANUAL

EA350. Generator Automatic Voltage Regulator Operation Manual

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Junior Max (JR Max ) Controller

SceneStyle2 User Guide

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

4 Wiring Brochure Wiring and installation of specific control

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Programmable Room Thermostat With RF

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

multi-function meters

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Operating Instructions for Throttle Valves Using VRC Valve Positioner

OUTDOOR IRRIGATION CONTROLLER LDC-6 LDC-11. User Manual

Trusted 40 Channel 120 Vac Digital Input FTA

Magnecraft Power Relays

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Figure 1: Device components

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

MS2540 Current Loop Receiver with RS485 Communication


INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

G.R.A.S. Sound & Vibration

Automatic Transfer Switch Control PLC Operator s Manual

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Catalogue Ignitors and power switches for HID

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

PRE-INSTALLATION ELECTRICAL POWER GUIDE

Solid-State Digital Timer

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

SAUTER flexotron RDT405 Manual

Model /29S RF Splitter

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Trusted 40 Channel 120 Vac Digital Input FTA

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Instruction Manual Model # Block Upconverter

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Multifunction Digital Timer

Do not insulation test (Megger) any circuits connected to this product.

ChannelPlus H17XL Series 2 User Operating Instructions

INSTALLATION INSTRUCTIONS FOR

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Operating instructions III / 2004

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Part-Turn Electric Multi-Turn Electric

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

Sentinel I24 Digital Input and Output Configuration

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

FWD8000 Dante enabled four wire box

Satellite B or D. Satellite Inputs (LNB Trunk)

Operating Manual RISH OPTIMA VAF

Model IQ4-PC User Manual Revision Date:

Certificate of Calibration

Danfoss Icon Programmable Room Thermostats, 230 V

Transcription:

MAKIG MODER LIVIG POSSIBLE TS715Si Electronic Single Channel Timeswitch with Service Interval Timer Danfoss Heating Installation Guide

For a large print version of these instructions please call Marketing on 0845 121 7400. Certification Mark Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 2 TS715SI

TS715Si Electronic Single Channel Timeswitch with Service Interval Timer Index 1.0 Installation Overview...4 2.0 Product Specification...4 3.0 Installation 3.1 Wiring...5 3.2 DIL Switch Settings...6 4.0 Advanced Programming Options...6 5.0 Copy Functions Explained...7 6.0 Service Interval Timer...9 7.0 Wiring Conversions...10-13 Danfoss Heating 3

1.0 Installation Overview Please ote: This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations. 2.0 Product Specification Specification 230V model 24V model Power supply 230 Vac, ±15%, 50/60 Hz 24 Vac, ±15%, 50/60 Hz Switching action 1 x SPDT voltage free, Type 1B Switch rating 24-230 Vac, 3(1)A Battery back-up 24 hours minimum Setting/Running Accuracy ± 1 minute Dimensions, mm (W, H, D) 135 x 88 x 32 Design standard E 60730-2-7 Control Pollution Situation Degree 2 Rated Impulse Voltage 2.5 kv Ball Pressure Test 75 C 3.0 Installation Remove wallplate from unit by unscrewing the two screws on the bottom edge of the unit. From the top left hand corner of the wallplate, there must be clearances of at least 140 mm to the right, 15mm to the left, 30mm above and 100mm below in order to mount the plug-on module. 4 TS715SI

The wallplate must be securely mounted either directly to the wall using suitable wood screws or to a flush mounted 1-gang electrical accessory box using M3.5 screws. Cable access can either be from behind for concealed cabling, or from below for surface cabling. If surface cable is used, cut out cable access slot on plug-on module prior to mounting. For wiring connections refer to diagram below. TS715 Si models are double insulated and do not require an earth connection, however a parking terminal is provided on the wallplate. This is clearly marked with an Earth symbol. Prior to mounting the plug-on module, DIL switches on the rear of the plug-on module must be set. See diagram on page 6 for available options. Mount plug-on module to wallplate by locating tabs on top of wallplate in apertures on rear of module, hinge down and press firmly to wallplate before tightening securing screws on bottom of wallplate. 3.1 Wiring For wiring conversion tables please see pages 10-13). Please ote: Link terminals L and 1 for standard mains voltage operated systems. On 24 volt models power supply must be wired to A & B on wallplate. 230 V fused 3A COM OFF O TS715 (3066 12/01) Please ote: Always switch off mains first and never fit programmer to a live wallplate. Danfoss Heating 5

3.2 DIL Switch Settings Before mounting the unit, ensure the 4 DIL switches on the rear have been moved to the required settings. Sw.1 Sw.2 ot Used ot Used ot Used ot Used Sw.3 5/2 Day 7 Day or 24 Hour Sw.4 7 Day 24 Hour Tick the ISTALLER SETTIG box on the inside flap label to notify user in which mode their unit is set (24hr, 5/2 day or 7 day). ISTALLER SETTIG 24 Hour 5+2 Day 7 Day 4.0 Advanced Programming Options To enter advanced programming press PROG, + and DAY/HOL together and hold for 5 seconds. Option 1 - (3 or 2 On/Offs per day) Use + or - to change between 3 or 2 on/offs each day. 3 2 3 on/offs each day (Factory setting) 2 on/offs each day Option 2 - (Disable or enable auto time change) Press EXT, then use + or - to change between auto time change enabled to auto time change disabled. Auto time change enabled (Factory setting) Auto time change disabled 6 TS715SI

Option 8 - (Advanced Copy Functions) Press EXT, then + or - to change between the following copy options: (0) Standard copy in 7 day and 5+2 day. (1) Enhanced copy in 7 day, standard copy in 5+2 day. (2) Enhanced copy in 7 day and AB copy in 5+2 day. For an explanation of the copy features and how to use them please see below. Press PROG to return to RU. 5.0 Copy Functions Explained There are 3 possible copy functions available. These are; Standard Copy, Enhanced Copy, and AB copy. Copy functions are enabled/ disabled in the Advanced Programming Options (page 6). Standard Copy: Pressing copy will copy the previous days events into the displayed day. The unit will then display the 1st event for the new day. This copy function is present only if the unit is set to run in 5+2 or 7 day mode. Enhanced Copy: The enhanced copy function is available in 7 day mode only. This allows any day to be copied to any other day, or days. To use the enhanced copy function go into the event programming using the PROG button, then: 1. Use the DAY button to find the day to be copied from. 2. Press the COPY button to select the day to be copied from. When selected, the day should begin to flash. 3. Use the DAY button to find the day to be copied to. 4. Press COPY button to copy the selected day. 5. Repeat steps 3 and 4 to select and copy other days. 6. To stop copying, use the DAY button to go back to the flashing day and press the COPY button. The previously flashing day will stop flashing to indicate it has been de-selected. OTE: When a day has been copied to, it will remain visible and not flashing when the DAY button is used to select other days. Danfoss Heating 7

AB Copy: The AB copy function is available in 5+2 mode only and only if activated in the Advanced Programming setting. A and B days, when selected, can be any group of days e.g. 5+2, 4+3 etc. The days do not have to run in sequence. For example, to operate in a 5+2 day mode the days can be set as follows: A Days Mon Tues Thurs Fri Sat B Days Wed Sun To use the AB copy function press the PROG button: 1. This will show the A days, with all the days selected. 2. Use the DAY button to highlight a day. 3. Subsequent presses of the DAY button will increment through the days. 4. Press the + button to select a specific day as an A day, or press the button to specify a day as a B day. 5. Once the day has been selected as an A or B day the programme will automatically jump to the next day. 6. When the last day of the week is active, pressing +, -, or DAY will move back to the A days displayed with no selected (flashing) days (see image below). 7. Repeat 2 to 6 until all selections have been made. 8. When selections are completed, press the PROG button to move to event programming. Event Programming in AB mode 1. Programme A day events using the + (time advance), - (time decrease), and EXT (next period) buttons. 2. Press the DAY button to change to programme the B days. 3. Programme B day events using the + (time advance), - (time decrease), and EXT (next period) buttons. 8 TS715SI

6.0 Service Interval Timer The TS715 Si is fitted with an installer setback service interval timer. If this feature is required please contact our technical department. Setting instructions for this gas safety feature are only available to bona fide heating installers. Danfoss Heating 9

7.0 Wiring Conversions (Applies only to 230 volt models) Wiring conversions for other timeswitches which can be replaced with the Danfoss TS715-Si, refer to the second part of the table. If in any doubt, please contact our Technical Services Department before proceeding with the replacement. DAFOSS RADALL TS715-Si MAIS The existing wallplate may be used when replacing the following, but the wiring m link between L & COM terminals of wallplate. ACL LS111, LS711, LP111 & LP711 L DRAYTO TEMPUS OE & TEMPUS TWO L LADIS & GYR RWB3 L LADIS & GYR RWB30 L The TS75/TS15 wallplate must be used to replace the existing wallplate when repla mains voltage systems, fit wire link between terminal 1 & L of wallplate. GRASSLI 45, 45A, 45E 2 1 HOEYWELL ST6100 L HORSTMA 423 PEARL, EMERALD & TOPAZ L HORSTMA KMK2A YMK2 3 4 HORSTMA 425 COROET L DAFOSS RADALL 911 L DAFOSS RADALL 103, 103E, 103E5 & 103E7 5 6 RADALL 3020 1,7 6 DAFOSS RADALL SET1 L RADALL TSR2 3 2 PEGLER SUVIC SP20 & SP25/30 L POTTERTO MYSO EP4001 L L L 10 TS715SI

LOAD COM OFF SPARE O An additional terminal block may be required where these disconnected leads (or pairs of leads) should be terminated 1 2 3 4 A B C D ust be reconnected as shown below. In addition, in mains voltage systems, fit wire 1 2 4 3 1 3 4 2-3 1 4 2 2 3 1 4 acing the following timeswitches. Wiring details are shown below. In addition, in 3-4 1 2 3 4 - - 3-1 4 2 5 6 1-2 5 6 1 4 2 3 5 4 2 6 3-2 1 - - 2 4 3 5 5 6 2 4 1-4 5 6 7 3 4 S 5 5 2 4 A B C D Danfoss Heating 11

DAFOSS RADALL TS715-Si MAIS The TS75/TS15 wallplate must be used to replace the existing wallplate when repla mains voltage systems, fit wire link between terminal 1 & L of wallplate. SAGAMO M6 4,5 6 SAGAMO 410 FORM 8 4,5 3 SAGAMO S254 FORM 2, S408 FORM 5, S251 FORM 2 SAGAMO S610 FORM 2, S611 FORM 2, S612 FORM 2, S408 FORM 4, S408 FORM 6, S253 FORM 2, S255 FORM 2 L L L MOTOR LIVE SAGAMO S409 FORM 8 3, 3,L SAGAMO S263 FORM 2 SAGAMO S264 FORM 2 L SMITHS ID. MKI, MKII L SMITHS ID. CETROLLER 30 1 2 SMITHS ID. CETROLLER 40 1 2 SWITCHMASTER L TOWERCHRO TC 2 1 VEER VEERETTE MKIIA L VEER VEERETTE MKIVA 2 3 VEER VEOTIME (WITH EO IDICATIG CIRCUIT O) L VEER VEOTIME (WITH EO IDICATIG POWER O) L VEER VEERO, VEERO P 3 2 12 TS715SI

LOAD COM OFF SPARE O An additional terminal block may be required where these disconnected leadss (or pairs of leads) should be terminated 1 2 3 4 A B C D acing the following timeswitches. Wiring details are shown below. In addition, in 3 2 7 1 8-2 6 1 7 8 - - LOAD SWITCH LIVE - LOAD 6-1 2 - OFF O P2 - P1 P3 - - 3 4,5 6 - - 3 4,5 4-2 1 3 4-3 7 8 9 10 11 LIE - LOAD 4-1 - 1 2 3 2 1 3 1-4 Danfoss Heating 13

14 TS715SI

Danfoss Heating 15

Danfoss Ltd. Ampthill Road Bedford MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk Part o. 38163v01s7-06 01/11