1 8 mm connector, 4-pin Visible red light Programming via teach cable or multi-function button Operating voltage: VDC IO-Link 2 x PNP output, changeover contact Light/dark operation Wiring Diagram Type designation Ident no Operating mode Photoelectric sensor for plastic fibers Light type Red Wavelength 660 nm Ambient temperature Operating voltage VDC Residual ripple < 10 % U ss DC rated operational current ð 40 ma Short-circuit protection yes Reverse polarity protection yes Output function NO/NC, PNP & IO-Link Switching frequency 5 khz Readiness delay ð 500 ms Response time typical < 0.2 ms Functional principle Glass or fiber optics are the optimum choice for high temperature or space restricted applications. Fiber optics transfer the light from the sensor to a remote object. Individual fiber optics are used for opposed mode sensing, whereas bifurcated fiber optics are suited for diffuse mode operation. Excess Gain Curve Approvals CE, culus listed IO-Link Specification V 1.1 IO-Link port type Class A Communication Mode COM 2 (38.4 kbaud) Process data width 16 bit Frame type Type_2_2 Minimum cycle time 2 ms Function Pin 4 IO-Link Function Pin 2 DI Maximum cable length 20 m Profilunterstützung Smart Sensor Profil Design Rectangular,DF-G1 Dimensions 79.3 mm x 10 mm x 33 mm Housing material Plastic, ABS, Black Electrical connection Connectors, M12 1 Cable cross section 4 mm 2 Protection class IP50 Special features Switching state Excess gain indication Pushbutton IO-Link LED,Yellow 7-digit LED 1 / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
2 Accessories DIN DIN rail, width 35 mm, length 70 mm DIN DIN rail, width 35 mm, length 105 mm DIN DIN rail, width 35 mm, length 140 mm Wiring accessories PKG4S-2/TEL Connection cable, female Ø 8 mm, straight, 4-pin, snap-on type, cable length: 2 m; sheath material: PVC, sheath color: black, culus approved, RoHS conform, protection class IP67 PKW4S-2/TEL Connection cable, female Ø 8 mm, straight, 4-pin, snap-on type, cable length: 2 m; sheath material: PVC, sheath color: black, culus approved, RoHS conform, protection class IP67 PKG4M-2-RSC4.4T/TXL Extension cable, M8 female - M12 male, straight, 4-pin, 2 m, sheath material: PVC, black; culus approval; other cable lengths and qualities available, see PKG4M-2/TEL Connection cable, female M8, straight, 4-pin, cable length: 2 m, sheath material: PVC, black; culus approval; other cable lengths and qualities available, see 2 / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
3 BL67-4IOL channel IO-Link Master module for the modular BL67 I/Osystem BL20-E-4IOL IO-Link master module for the modular BL20 I/O system, 4- channel USB-2-IOL IO-Link Master with integrated USB port TBIL-M1-16DXP channel I/O-hub for the connection of 16 digital PNP signals to an IO-Link master (input/output freely selectable per channel) TBEN-S2-4IOL Compact multiprotocol I/O module, 4 IO-Link Master 1.1 Class A, 4 universal PNP digital channels 0.5 A 3 / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
4 BL20-E-4IOL IO-Link master module for the modular BL20 I/O system, 4- channel PBT16U Plastic fibre-optic sensor, operating mode: Diffuse mode, threaded sleeve M3 x 0.75 mm, field wireable wire without PBT26U Plastic fiber, sensing mode: Diffuse mode, threaded bush M3 x 0.75 mm, preassembled wire without end tip, polyethylene jacket, ambient temperatures -30 PBT46U Plastic fibre-optic sensor, operating mode: Diffuse mode, threaded sleeve M3 x 0.75 mm, field wireable wire without PBT66U Plastic fibre-optic sensor, operating mode: Diffuse mode, threaded sleeve M6 x 0.75 mm, pre-assembled wire without 4 / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
5 PIT16U Plastic fibre-optic sensor, operating mode: Opposed mode, PIT26U Plastic fiber, sensing mode: Opposed mode, threaded bush M3 x 0.5 mm, preassembled wire without end tip, polyethylene jacket, ambient temperatures -30 PIT46U Plastic fibre-optic sensor, operating mode: Opposed mode, PIT66U Plastic fibre-optic sensor, operating mode: Opposed mode, 5 / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ
Transmission of process value and parametrization via IO-link Cable with male end, PVC, M8 x 1, 4-pin, 150 mm Protection class IP67 LED, all-round visible Coaxial optics Sensitivity adjusted via teach
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 310 mm Laser class 1, red, 655 nm, acc.
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 610 mm Laser class 1, red, 655 nm, acc.
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 100 mm Laser class 1, red, 655 nm, acc.
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 300 mm Laser class 1, red, 655 nm, acc.
More informationUltrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151
Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:
More informationUltrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD
ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment
More informationCapacitive sensor BCT5-S18-UP6X2T-H1151
M18 1 threaded barrel Plastic, PA12-GF30 Teach-in and configuration via buttons on the device, pin 5 and IO-Link Wiring Diagram Functional principle Type designation Ident no. 2101100 Remark to product
More informationContactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationBL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog
More informationContactless encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED LED indicates measuring range Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024,
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationContactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. output 25 bit, Gray-coded clock rate: 62.5 KHz 1 MHz Single or multiturn, length
More informationContactless encoder Ri360P0-QR24M0-HESG25X3-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. SSI output 25 bit, Gray-coded SSI clock rate: 62.5 KHz 1 MHz Single or multiturn,
More informationInductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151
Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog
More informationRead/write head TN-CK40-H1147
Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated only via BL ident
More informationContactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 16 bits singleturn Process value in 32 bit telegram 3 error bits 16 bits singleturn 15
More informationRead/Write Head TNLR-Q80L400-H1147L
For roller conveyors The approach direction of the data carrier can be both, diagonal as well as longitudinal to the read/write head. Rectangular, 80 x 400 mm, height 25 mm Active face on top Plastic,
More informationRead/Write Head TNSLR-Q42TWD-H1147
Rectangular, height 42.5 mm Active face on top Plastic, PA12-GF30 /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030424 Mounting conditions Non-flush Ambient temperature -25 +70 C Operating
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationRead/write head TN-M18-H1147
Threaded barrel, M18 x 1 Chrome-plated brass Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated solely via BLident interface module M12 x 1 male,
More informationRotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181
Clamping flange, Ø 58 mm Solid shaft, Ø 10mm x 20mm Optical measuring principle Shaft material, stainless steel Protection class IP67 on the shaft side -40 +85 C Max. 6000 rev/min (continuous operation
More informationRead/Write Head TN-M30-H1147
Threaded barrel, M30 x 1.5 Chrome-plated brass /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030004 Mounting conditions Non-flush Ambient temperature -25 +70 C Operating voltage 10 30
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationRadio Transmission System Point-to-point Gateway DX80G2M6S-PM8
External antenna (RG58 RP-SMA connection) Integrated signal strength indicator Configuration via DIP switch Modbus RTU communication, RS485 interface Deterministic data transmission Frequency hopping FHSS
More informationContactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151
Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output
More informationRead/Write Head TN-CK40-H1147
Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030006 Mounting conditions Non-flush Ambient temperature -25
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSet for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8
Type code Ident no. 1545077 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between
More informationBL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog
More informationCSM Color sensors. Color sensors for the detection of a single color in restricted space conditions
CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance
More informationBL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 4 analog
More informationMobile data carrier TW-L49-46-F-B128
EEPROM, memory 128 byte Functional principle The HF read/write heads operating at a frequency of 13.56 MHz, form a transmission zone the size of which (0 500 mm) varies, depending on the combination of
More informationAmplifier for fiber optics. Dimensioned drawing
Amplifier for fiber optics Dimensioned drawing up to 525mm up to 120mm 10-30 V DC 3-digit display for indicating and setting the switching threshold NEW: AutoSet function for easy sensor adjustment Menu
More informationTW-R30-K2. FRAM memory 2 kb. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission
FRAM memory 2 kb Functional principle The HF read/write heads operating at a frequency of 13.5 MHz, form a transmission zone the size of which (0 0 mm) varies, depending on the combination of read/write
More informationBL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P
On-Machine kompakt fieldbus I/O blokları CANopen slave 10, 20, 50, 125, 250, 500, 800, or 1000 kbps Two 5-pin M12 male receptacles for fieldbus connection 2 rotary coding switches for node-address IP 69K
More informationPressure sensors with display
412 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 sensors P sensors PK series series Multifaceted pneumatic specialists The PK pressure sensors are especially designed for pneumatic
More informationTW-R16-B128. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission
EEPROM, memory 8 byte Functional principle The HF read/write heads operating at a frequency of 13.56 MHz, form a transmission zone the size of which (0 0 mm) varies, depending on the combination of read/write
More informationConnectivity for Ethernet
Industrial Ethernet standards such as Modbus TCP, EtherNet/IP, PROFINET and Ether- CAT have firmly established themselves in automation technology. These real-time Ethernet solutions differ both in terms
More informationADVANCED ultrasonic sensors with analog output. Dimensioned drawing
ADVANCED ultrasonic sensors with analog output Dimensioned drawing en 07-2017/02 50124880 4...20 ma 0...10 V 25 400mm 150 1300mm 15-30 V DC We reserve the right to make changes PAL_DMU418BX3LTVC_en_50124880.fm
More informationInductive coupling. 10 mm +/-0.2 mm
Data carrier for direct mounting on metal The mounting position (arrow) as well as the alignment of the data carrier towards the read/write head must be observed under all circumstances in order to achieve
More informationSU17 Series Fiber Optic Sensors
SU17 Series Fiber Optic Sensors Fiber Optic Diffuse and Thru-Beam Mode See page 750 Sensing Range: Determined by fiber optic cable Output: NPN, PNP Built-in auto-tuning Digital display Mutual interference
More informationBMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description
Component Systems Technical Description Features Applications The mini optical series of sensors are among smallest sensors in the world. Mini optical sensors require almost no space and with their low
More informationYour Global Automation Partner. Ultrasonic Sensors. Operating Instructions
Your Global Automation Partner RU CK40 RU CP40 Ultrasonic Sensors Operating Instructions Contents 2 Hans Turck GmbH & Co. KG T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com Contents 1
More informationTechnical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.
Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options
More informationElectrical connection
Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication
More informationEtherCAT Set in IP20 TI-BL20-E-EC-S-4
A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BLident M12 extension
More informationElectrical connection
Colour sensors Dimensioned drawing en 02-2014/05 50109619-01 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct
More informationtechnical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current
Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationW100L: Laser Sensor in Mini- Format
Product group W00 Laser Photoelectric proximity switch energ. Photoelectric reflex switch W00L: Laser Sensor in ini- Format Through-beam photoelectric switch Where applications demand it, the sensor can
More informationD12 Expert Series TEACH-Mode Fiber Optic Sensors
TEACH-Mode Fiber Optic Sensors One-button programmable sensors for use with glass or plastic fibers D Expert Features Fiber optic sensors for DIN rail mounting; 0 to 30V dc operation Visible red (680 nm)
More informationHigh Resolution Multicolor Contrast Scanner. Dimensioned drawing
Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes
More informationThe full range of performance
sensors sensors P sensors PS series series The full range of performance The sensors of this series cover all important pressure ranges from -1 +600 bar with an accuracy of 0.5% f.s.. Bar, psi and further
More informationTechnical data. General specifications. Indicators/operating means
Model Number Single head system Features Sensor head bidirectional and rotatable Function indicators visible from all directions Quick mounting bracket Selectable sound lobe width Programmable Diagrams
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationW 190 L: Application-based Laser Technology, the optimum solution for demanding applications
Photoelectric proximity switches Photoelectric reflex switches W 90 L: Application-based Laser Technology, the optimum solution for demanding applications Do your customers require reliable sensors suitable
More informationYour Global Automation Partner. Ultrasonic Sensors
Your Global Automation Partner Ultrasonic Sensors At TURCK, we understand that not every application is the same. That s why we dedicate ourselves to finding the optimal engineered solution for every application;
More informationElectrical connection
Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in
More informationDimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.
Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin,
More informationFiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements
NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected
More informationSet for Simple I/O Communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-2
Tip kodu İdent no. 1545074 Kanal sayısı 2 Boyutlar (W x L x H) 72.5 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between interface
More informationV 180 Series Photoelectric Switches
D A T A S H E E T V 180 Series Photoelectric Switches VS 180 / VE 180 1 m x VL 180 m 1 m*) *) with polarizing filter v VT 180 110 mm 00 mm n Photoelectric switches of cylindrical design in threaded metal
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationSensor technologies Proximity sensors Series ST4. Brochure
Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with
More informationElectrical connection
Splice sensor Dimensioned drawing en 04-2014/06 50116166-01 4mm 12-30 V DC We reserve the right to make changes DS_IGSU14CSD_en_50116166_01.fm Reliable detection of splice on paper web or plastic web With
More informationENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:
ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationLUT Luminescence scanners: Seeing what no-one else can
LUT Luminescence scanners Luminescence scanners LUT Luminescence scanners: Seeing what no-one else can Special features: A semi-conductor light source is used in the LUT series no lamp change required.
More informationWLS27 Multicolor LED Strip Light with EZ-STATUS
WLS7 Multicolor LED Strip Light with EZ-STATUS Instruction Manual Banner's WLS7 Multicolor LED Strip Light has a sturdy aluminum housing and is encased in a shatterproof, UV-stabilized, copolyester shell,
More informationWF next: Fork sensors for a wide range of applications
WF next: Fork sensors for a wide range of applications D ATA S H E E T Fork sensors TThe detection of labels, marks and double sheets, as well as holes and edges are typical applications for the new WF
More informationultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs
18, 30 1 design M18x1 M30x1.5 dif. reflection sensor sensing range (teachable) 30... 400mm 60... 500mm 100... 800mm 80... 1500mm 200... 2000mm 300... 3500mm PBT plastic sleeve devices with thread to EURONORM
More informationDCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor
Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital
More informationOrdering details. Approval. Classification
Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation
More informationInstallation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors
Mechanical Electrical Optical Cat No. Strobing Models COS Models Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors Polarized Retroreflective Retroreflective Standard Diffuse
More informationAmplifier for fiber optics. Dimensioned drawing
Amplifier for fiber optics Dimensioned drawing with cable en 01-2012/09 50118006 up to 1050mm up to 270mm with M8 connector 10-30 V DC We reserve the right to make changes DS_LV463_en_50118006.fm wo, large,
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationDF-G3 Long Range Expert Dual Display Fiber Amplifier
DF-G3 Long Range Expert Dual Display Fiber Amplifier Quick Start Guide Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies; single or dual independent output
More information1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for
More informationElectrical connection
(I)GSU 14C Ultrasonic Label Fork Dimensioned drawing en 06-2011/12 50109234-01 4mm 12-30 V DC 4 m/s We reserve the right to make changes DS_IGSU_14C_en.fm Ultrasonic forked sensor for universal application
More informationOperating Instructions
CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target
More informationDatasheet - SRB-E-201ST
27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574
More informationSlot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON
Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationCylindrical Photoelectric Sensor CY-100 SERIES
Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector
More informationENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:
ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental
More informationOnline data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS
Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information
More informationSensor technologies Distance measuring sensors Series SM6. Brochure
Series SM6 Brochure Series SM6 6 mm groove with cable without wire end ferrule, tin-plated, -pin with distance measuring sensor, measurement range - 56 mm 6 mm groove with cable Plug, M8x, -pin, with knurled
More informationEZ-STATUS WLS28-2 Multicolor LED Strip Light
EZ-STATUS WLS8- Multicolor LED Strip Light Datasheet Banner's WLS8- Multicolor LED Strip Lights have sturdy aluminum housings, shatterproof windows, and environmental ratings that make it ideal for harsh
More informationDF-G3 Long Range Expert Dual Display Fiber Amplifier Instruction Manual
DF-G3 Long Range Expert Dual Display Fiber Amplifier Instruction Manual Original Instructions 187436 Rev. F 21 April 2017 Banner Engineering Corp. All rights reserved 187436 Contents 1 Product Description...3
More informationW 9-2: A Versatile, Complete and Compact Series
suitable sensor can be selected from the W 9- series. Overview of the sensors: WT 9-, with adjustable background suppression, max. scanning distance 0 mm, WT 9-, energetic, max. scanning distance 0 mm,
More informationDF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Instruction Manual
DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Instruction Manual Original Instructions 190341 Rev. E 21 April 2017 Banner Engineering Corp. All rights reserved 190341 Contents
More informationPressure transmitter COMPACT IO-Link,
Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationRLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:
RLS Series RLS-GD-20/20 -UV Detection of Glass Coating - Insensitive to outside light due to clocked UV illumination - Receiver (20 ) and reference - Storing of up to 31 gloss degrees (gloss values) -
More informationSPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)
SPECTRO Series SPECTRO-3-30-UV - Measuring range typ. 15 mm... 80 mm - Ideal adjustment to luminescent objects - Up to 31 colors can be stored - RS232 interface (USB or Ethernet adapter is available) -
More information45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5
SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable