1 Product Certificate Number Applicant CER Huawei Technologies España Parque Empresarial Las Tablas, Federico Mompou 5, Ed. 1 planta Las Tablas. Madrid, Spain. Series Model/ Variant models Type of generating unit Technical Data See page 2-8 String Inverters SUN 2000-KTL, IA240 Series, EM24 DIN, CTD-1X, SUN KTL, Moxa / IA240, Carlo Gavazzi / EM24-DIN.AV5.3.D.IS.X, Carlo Gavazzi / CTD-1X.200.5A.XXX Inverters: SUN KTL, SUN KTL, SUN KTL, SUN KTL, SUN KTL, SUN KTL, SUN KTL-A, SUN KTL Three Phase Inverter / Control Manager / Power Analyzer / Current sensor Standard UNE IN: 2015: Requisitos y ensayos para sistemas que eviten el vertido de energía a la red de distribución. Having assessed the test report number: TR performed by Certification Entity for Renewable Energies based on the requirements of the EN ISO/IEC 17025:2005 The above-mentioned generating unit complies with the requirements of the: UNE IN: 2015: Requisitos y ensayos para sistemas que eviten el vertido de energía a la red de distribución. This certification is according the CERE internal process PET-CERE-09 Rev 11 based on the requirements of the EN ISO/IEC 17065:2012. For this certification process the conformity assessment activities were based on: Testing of production samples selected by CERE. Audit of quality system according ISO 9001 with certificate number: ES13/14411 issued by a certification body accredited according EN ISO/IEC Inspection of the software implementation process. Madrid, October 6, This certificate is valid until October 6, 2020 Miguel Martínez Lavin Certification Manager This document cannot be reproduced partially. Nº CER Page 1 of 9
2 Inverters: HUAWEI Technical Specifications SUN2000-8KTL SUN KTL Max. DC Usable Power 9000 W W Max. Voltage 1000 V 1000 V Max. Current per 18 A 18 A Min. Operating Voltage / Start Voltage 25 A 25 A 200 V / 250 V 200 V / 250 V Full Power Voltage Range 320 V ~ 800 V 380 V ~ 800 V Operating Voltage Range 200 V ~ 950 V 200 V ~ 950 V Rated Voltage 620 V 620 V Max. Number of s 4 4 Number of MPP Trackers 2 2 Rated AC Active Power 8000 W W Max. AC Apparent Power 8800 VA VA Max. AC Active Power (cos Φ = 1) 8800 W W Rated Voltage 220 V / 380 V, 230 V / 400 V, 220 V / 380 V, 230 V / 400 V, Rated AC Grid Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Max. Current 13,4 A 20 A Adjustable Power Factor 0,8 LG 0,8 LD 0,8 LG 0,8 LD -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester Type II Type II AC Surge Arrester Type II Type II Insulation Detection Residual Current Monitoring Unit This document cannot be reproduced partially. Nº CER Page 2 of 9
3 Technical Specifications SUN KTL SUN KTL Max. DC Usable Power W W Max. Voltage 1000 V 1000 V Max. Current per 18 A 18 A Min. Operating Voltage / Start Voltage 25 A 25 A 200 V / 250 V 200 V / 250 V Full Power Voltage Range 400 V ~ 800 V 480 V ~ 800 V Operating Voltage Range 200 V ~ 950 V 200 V ~ 950 V Rated Voltage 620 V 620 V Max. Number of s 6 6 Number of MPP Trackers 3 3 Rated AC Active Power W W Max. AC Apparent Power VA VA Max. AC Active Power (cos Φ = 1) W W Rated Voltage 220 V / 380 V, 230 V / 400 V, 220 V / 380 V, 230 V / 400 V, Rated AC Grid Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Max. Current 28,4 A 33,4 A Adjustable Power Factor 0,8 LG 0,8 LD 0,8 LG 0,8 LD -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester Type II Type II AC Surge Arrester Type II Type II Insulation Detection Residual Current Monitoring Unit This document cannot be reproduced partially. Nº CER Page 3 of 9
4 Technical Specifications SUN KTL SUN KTL Max. DC Usable Power W W Max. Voltage 1000 V 1000 V Max. Current per 18 A 18 A 25 A 25 A Max. input current (3 s) 54 A 54 A Min. Operating Voltage 200 V 200 V Voltage Range 480 V ~ 800 V 480 V ~ 800 V Rated Voltage 620 V 620 V Max. Number of s 6 6 Number of MPP Trackers 3 3 Rated AC Active Power W W Max. AC Active Power (cos Φ = 1) Rated Voltage 220 V V /380 V V, 227 V / 480 V, 3W+PE Rated AC Grid Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Max. Current 33,5 A 33,5 A Adjustable Power Factor 0,8 LG 0,8 LD 0,8 LG 0,8 LD -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester Type II Type II AC Surge Arrester Type III Type III Insulation Detection Residual Current Monitoring Unit This document cannot be reproduced partially. Nº CER Page 4 of 9
5 Technical Specifications SUN KTL-A SUN KTL Max. DC Usable Power W W Max. Voltage 1100 V 1100 V Max. Current per 22 A 22 A Min. Operating Voltage / Start Voltage 30 A 30 A 200 V / 250 V 200 V / 250 V Full Power Voltage Range 480 V ~ 800 V 480 V ~ 850 / 400 Vac Operating Voltage Range 200 V ~ 1000 V 200 V ~ 1000 V Rated Voltage 620 V 620 / 400Vac Max. Number of s 8 8 Number of MPP Trackers 4 4 Rated AC Active Power W W Max. AC Apparent Power VA VA Max. AC Active Power (cos Φ = 1) W Default 40000W; 36000W optional in settings Rated Voltage 230 V / 400 V, default 220 V / 380 V, 230 V / 400 V, default ; 3W+PE optional in settings 227V/480V, 3W+PE Rated AC Grid Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Max. Current 48 A (@400V) 60,8 A / 57.8 A / 48,2 Adjustable Power Factor 0,8 LG 0,8 LD 0,8 LG 0,8 LD -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester Type II Type II AC Surge Arrester Type II Type II Insulation Detection Residual Current Monitoring Unit This document cannot be reproduced partially. Nº CER Page 5 of 9
6 Technical Specifications Max. DC Usable Power Max. Voltage Max. Current per Min. Operating Voltage / Start Voltage Full Power Voltage Range Operating Voltage Range Rated Voltage SUN KTL W 1100 V 22 A 30 A 200 V / 250 V 580 V ~ 850 V 200 V ~ 1000 V 720 V Max. Number of s 8 Number of MPP Trackers 4 Rated AC Active Power Max. AC Apparent Power Max. AC Active Power (cos Φ = 1) Rated Voltage Rated AC Grid Frequency Max. Current Adjustable Power Factor -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester AC Surge Arrester Insulation Detection Residual Current Monitoring Unit W VA Default 47000W; 42000W optional in settings 277 V / 480 V, 3W+PE 50 Hz / 60 Hz 56,6 A 0,8 LG 0,8 LD Type II Type II This document cannot be reproduced partially. Nº CER Page 6 of 9
7 Control manager: CPU RAM Flash OS LAN Serial Ports Serial Power input Power consumption Operating temperature Storage temperature Baudrate Moxa/IA240 Moxa ART ARM9 32-bit CPU 192 MHz 64MB 16 MB Linux Auto-sensing 10/100 Mbps x 2 with built-in 1.5 KV magnetic isolation protection; RJ45 Connector RS-232/422/485 4, RJ45 Connector 15 KV ESD for all signals 12 to 48 VDC 7W -10 to 60 C, (14 to 140 F), 5 to 95% RH -20 to 80 C, (-4 to 176 F), 5 to 95% RH 50 bps to kbps Relay: Moxa/IoLogik E1214 s and s Digital inputs 6 channels Relay s 6 channels Isolation 3 k VDC or 2k Vrms Digital Sensor Type Wet Contact (NPN or PNP), Dry Contact I/0 Mode DI OR Event Counter Counter frequency 250 Hz Digital Filtering Time Interval Software Configurable Relay Contact current rating Resistive Load: 5 30 VDC, 250 VAC, 110 VAC Breakdown voltage 500 VAC Relay On/Off time 1500 ms (max.) Power Analyzer: Carlo Gavazzi/EM24-DIN.AV5.3.D.IS.X Range codes Rated Voltage 3x230 V (400) V Current range 0,05 5 (10) A Sampling rate Hz Operating temperature -25ºC to 55ºC Accuracy 0,5% This document cannot be reproduced partially. Nº CER Page 7 of 9
8 Current sensor: Carlo Gavazzi/CTD-1X.200.5A.XXX Specifications Operating frequency 48 to 62 Hz Rated primary current 200A Max. System voltage 0.72 kv Rated insulation level 3 Hz Insulation class E (max 75 ºC) Short-time current rating Ith Typical 100In/1s Idyn 2.5 Ith Specifications Rated secondary current 5 A Accuracy 0,5% Switch of grid (Contactor): Contactor application Utilisation category System Voltage Ie rated operational current Uc control circuit voltage Overvoltage category I th Ui rated insulation voltage Schneider/LC1DT80AF7 Resistive load AC V AC Hz power circuit 80 A 110 V III 80 A 690 V This document cannot be reproduced partially. Nº CER Page 8 of 9
9 Electrical Diagram: The sample selected to test was representative of the production. The sample was selected in: (1) Huawei Technologies España Parque empresarial Las Tablas, Federico Mampou 5, edificio Madrid (2) Green Power Monitor Av. de Josep Tarradellas, Barcelona, Spain Sample Report Number: The inspection of manufacturing process was performed in: On October 5, 2017 Inspection Report Number: (1) TM (2) TM Tempel Group Carrer del Cobalt, L'Hospitalet de Llobregat Barcelona, Spain IF This document cannot be reproduced partially. Nº CER Page 9 of 9
Assembly. Front view. LEDs. Parametrization interface. Power Bus
otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit
More informationSUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL
STP 8000TL-10 / STP 10000T-10 / STP 12000TL-10 / STP 15000TL-10 / STP 17000TL-10 SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL Economical Reliable Flexible Simple Maximum efficiency of
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More informationOrdering details. Approval. Classification
Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation
More informationPROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS
INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationLONWORKS Fibre Optic Router
LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS
More informationStandard RS232 RS ma
1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision
More informationLONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationThe Three-Phase Inverter Not Only for Your Home...
SUNNY TRIPOWER 5000TL 12000TL STP 5000TL-20 / STP 6000TL-20 / STP 7000TL-20 / STP 8000TL-20 / STP 9000TL-20 / STP 10000TL-20 / STP 12000TL-20 NEW available as 10 kva and 12 kva versions Economical Flexible
More informationPRINCIPLES AND APPLICATIONS
GENERATION & NETWORK Digital Automation Measuring and Control Devices AMS7000 PROCOM The optimum operation of an electrical network depends particularly on the reliability and the availability of the protection,
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationPRELIMINARY Sunny Boy 240-US
PRELIMINARY Sunny Boy 240-US SB 240-US-10 Optimized reliability Simple installation Unrivaled monitoring SMA-backed security Multigate technology allows for reduced component count Private band powerline
More informationDatasheet - SRB-E-201ST
27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationFibre optic router for TP/FT-10 LRW-112PP
Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT
More informationFibre Optic Modem ODW-611
Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationAdvantys STB DATA SHEET. Advantys STB Output Module. Description. Features
Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The
More informationINSTALLATION MANUAL FT-FOTR-1VDE-ST-S
INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package
More informationOperating Instructions
COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic Preselection Counter Two preselections NE 216 Contents Page 1 Safety indications... 2 2 Get to know your NE 216... 4 2.1 NE216 components...
More information1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationMCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features
Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: ICAO: IEC: 61822 CENELEC: AC 150/5345-10 (current edition), L-828, L-829. Aerodrome Design Manual Part 5, para. 3.2 (current
More informationZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features
Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationType Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model
Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications.
More informationMAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams
MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic
More informationOperating instructions Electronic preset counter Type series 717
Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range
More informationSPACESCAN SERIES SS 02
Description 0-10 metre sensing range 12 to 384 channels Available with channel spacing of 5, 10 or 20 mm Active length of 225 mm to 1920 mm Housing length of 300 mm to 1980 mm Plug connection 18-30 V dc
More informationFibre Optic Modem ODW-622
Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.
More informationDATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.
Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features
More informationMAP110 AC-DC Series Data Sheet
Description Single-Output Model Selection VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012
More informationTime-Lag Relays. User s Handbook (General Model)
Time-Lag Relays User s Handbook (General Model) 651.601.387 Rev: V39 Date: 09/2016 Electrotécnica Arteche Smart Grid, S.L. This document, including texts, photos, graphics and any other content, is protected
More informationAF-300 E11 Adjustable Frequency Drive
AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed
More informationMultifunction Digital Timer
Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
More informationSingle output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.
RoHS Lead-Solder-Exemption Compliant New 3.3 V and 5 V Output Models Universal Input 85-264 VAC Industry-Standard Footprint: 7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm) Input Transient & ESD Compliance
More informationLXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O
Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number
More informationT +31 (0) F
Thomas Feed is a computer for the control of a dry feed system that is used to give all of your animals ad-lib feeding. This computer is exceptionally easy to use. Icons on the large screen show the available
More informationElectronic converter for level transmitters MT03L Instructions manual
Electronic converter for level transmitters MT03L Instructions manual R-MI-MT03L Rev.: 1 English version PREFACE Thank you for choosing the MT03L converter from MT03 series of Tecfluid S.A. This instruction
More informationDA E: Series of Narrowband or Wideband Distribution Amplifiers
DA1-150-10-E: Series of Narrowband or Wideband Distribution Amplifiers Key Features Dual A and B inputs. Automatic or manual switchover, configured by the Ethernet port. 1-150 MHz wideband operation. Other
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationGenerator protection relay
Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Off-the-shelf generator protection relay for small and medium sized power generators Three-phase time overcurrent and
More informationType Contact form Model
Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationElectrical connection
Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication
More informationDCP100 Digital Control Programmer Specifications
DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,
More information2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR
2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR Power supply It is based upon the latest switch mode power supply technology, offering size reduction (i.e. 19 rack, 3U power supply), good
More informationSolid-State Digital Timer
Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,
More informationGPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs
ED5219LGT Series GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs The ACI ED5219LGT series is a high-power multi-ports EDFA optical booster with gain spectrum bandwidth from 1545 to
More informationSlot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON
Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationSelf Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual
Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual s * Use for reference purpose only and not a genuine Marathon product. 1. INTRODUCTION Sensing Input
More informationRK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLight Curtain Type LA
Light Curtain Type LA Status: 2011-04-27 Subject to change without notice. No responsibility is taken for the correctness of this information. Your suggestions for corrections or improvements are welcome!
More informationWeekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N
Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control
More informationElectrical connection
Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in
More information2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer
LE7M-2 W72 H72mm, Weekly/Yearly Timer Features Easy to check and change the program setting Customizable weekly or yearly unit time setting and control by user Includes daylight saving time function Built-in
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More informationSPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)
SPECTRO Series - Measuring range typ. 10 mm... 150 mm - Big dynamic range due to focused white-light operation - Up to 31 colors can be stored - RS232 interface (USB or Ethernet adapter available) - 8x
More informationLC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationAccessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards
BREAK-TW-V.4/4, BREAK--V.4/4 BOX DIN RACK IP56 Optoconverters are designed to transfer videosignal and or data. I FM modulation I AGC optical loss I Universal for MM and SM fibres I Up to 3 independent
More informationE8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors
Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSelection matrix for electronic pressure switches
Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film
More informationFLOMAT Electromagnetic Insertion Flowmeter
LOMAT Electromagnetic Insertion lowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction or use in large diameter pipes or open channels as an
More informationElectronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,
Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999
More informationA new generation of access control.
TM A new generation of access control. 2 or 4 Door Expandable Controller INSTALLATION MANUAL Installation overview: Installation Diagram Switch Alpha 4 Alpha 4 + PoE Alpha 4 + PoE Alarm central Accessory
More informationQuick Operation Guide of LTN7700/7600 Series NVR
Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More information6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000
6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000 NEWPORT PRODUCT INFO MANUAL (HTML) - (PDF Version) P6000A/P5000 - INPUT OPTIONS
More informationG5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type
s with Built-in Linear Motor Type R88D-KN@-ECT-L Contents Ordering Information Specifications General Specifications Characteristics Servo Drives with 100 VAC Input Power Servo Drives with 200 VAC Input
More informationZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.
CSM DS_E_1_1 Continuously monitor dust fallout and particles which detract from product quality. Compact design ideal for continuous monitoring Equipped with various interfaces such as a LAN port. Accurately
More informationManual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12
R60722.0002 - Index 3 Analog (U/I) Manual Absolute multiturn encoder Order code: 8.M36X1.XXXX.XX12 Order code: 8.M3661R.XXXX.XX12 Order code: 8.M5861.XXXX.XX12 Publisher Kübler Group, Fritz Kübler GmbH
More informationMINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description
Frequency transducers Data sheet 105_en_01 PHOENIX CONTACT 01-08-19 1 Description Configurable -way isolated frequency transducer. The device is suitable for the connection of NAMUR proximity sensors (IEC
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSPECIFICATION ESD FSP500-80MPD. Released Date:2015/07/27-14:41:38
SPECIFICATION ESD14050296 FSP500-80MPD Released Date:2015/07/27-14:41:38 1/9 禁止翻印外洩 All rights reserved ESD14050296-R3.pdf 檔案建立時間 :2015/7/27 2:41 下午 SPECIFICATION FSP500-80MPD Main Feature: Active PFC
More informationDatasheet IVU.box.touch
Datasheet IVU.box.touch Standard Features CPU Freescale ARM11 i.mx 35 @ 532MHz Operating System Microsoft Windows CE 6.0 Internal mass storage device RAM Removable mass storage device Human User Interface
More informationPanel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features
NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description
More informationMG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV
MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper
More informationInstallation and User Guide 458/CTR8 8-Channel Ballast Controller Module
Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach
More informationInstruction Manual Model BlockUpconverter
Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationSPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:
SPECTRO Series SPECTRO-3-30-UV-ANA - Measuring range typ. 15 mm... 80 mm - Transmitter power of UV LED can be adjusted for excitation of luminescent marks - Up to 3 colors (or color groups) can be stored
More informationLC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil
Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil
Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More informationSPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:
SPECTRO Series SPECTRO-3-50-COF-...-CL - Measuring range typ. 30 mm... 70 mm - Integrated transmitter and receiver optics (confocal) - Up to 31 colors can be stored - RS232 interface (USB or Ethernet adapter
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationmulti-function meters
multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6
More informationEA350. Generator Automatic Voltage Regulator Operation Manual
Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator For General Generators Compatible with Marathon SE350* * Use for reference purpose only and not a genuine
More informationFOM-9010, FOM-9011 and FOM-9012
Control and Alarm Voltage sense, open collector, or contact inputs Features: FOM-00: Voltage Sense, Open Collector, or Dry Contact Inputs. State Detection for TIA-, TIA-, and TTL Signals. FOM-0: SPDT Form
More informationWeekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min
Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable
More informationORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA
BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps
More informationHYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.
Constant current LED driver DALI Dimmable Product description Dimmable Independent constant current Adjustable output current between 350 and 1,050mA via DIP switch Max. output power 35 W Up to 88 % efficiency
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationProduct Range Power Supplies
aschenbrenner a elektronik gmbh Product Range Power Supplies Aktualisiert 2018 / 04 Phone.: +49 (0) 8031-6506-0 www.aschenbrenner-elektronik.de DC / DC Power Supplies 12 V DC Output type numbers: 00791
More informationMT03A Electronic converter for flow rate transmitters
Instructions manual MT03A Electronic converter for flow rate transmitters The art of measuring R-MI-MT03A Rev.: 0 English version PREFACE Thank you for choosing a Tecfluid S.A product. This instruction