Signalling Devices. 516 Signalling Devices KP00 III en Preferred products in stock or available at short notice

Size: px
Start display at page:

Download "Signalling Devices. 516 Signalling Devices KP00 III en Preferred products in stock or available at short notice"

Transcription

1 516

2 Contents Audible and Visual Yodalex Super Series, GRP Combination Signal db(a) / 5 Joule YL6S 518 Sounder / Strobe, Combination db(a) / 5 Joule YL Intrinsically Safe Combination Signal db(a) / LED Beacon YL4IS 527 Intrinsically Safe Combination Signal db(a) / LED Beacon YL5IS 527 Audible Intrinsically Safe Sounder, 100 db(a) YO3IS 527 Intrinsically Safe Sounder, 100 db(a) Modular YO4IS 527 Intrinsically Safe Sounder, 105 db(a) YO5IS 527 Sounder, 115 db(a) YA Yodalex Super Series, GRP Flameproof Audible Signal db(a) YA6S 518 Sounder, 110 db(a) YA Sounder db(a) - Hazardous Area YA Hazardous Area Loudspeaker - 25 or 15 W Signal Horn, 105 db(a) Visual Yodalex Super Series, GRP Flameproof Visual Signal - 5 Joule FL6S 518 Strobe, Flash Energy 5 Joule FL GRP Explosion Proof Visual Signal 5 Joule FX Flashing Beacon and Continuous Beacon Signal Beacon - LED LED Obstruction Light, Low Intensity TEF Obstruction Light LED TEF Signal Beacon TEF Signal Beacon - Zone 2 TEF Perimeter Light - LED TEF LED Visual Flashing Signal, Intrinsically Safe FD40IS 555 LED Visual Status Signal, Intrinsically Safe SD40IS 555 Navigation Light TEF Windsock Illuminated TEF Windsock with Internal Illumination TEF Control Devices Manual Call Points MCP 572 You will find further information on the Internet Audible Sounder 8493 Visual Traffic Light 6091 Control Devices Fire Alarm Stations

3 Yodalex Super Series Series YL6S, YA6S, FL6S & > Corrosion resistant light-weight Ex d enclosure made of glass-fibre reinforced polyester > Extreme temperature range > IP66 & IP67 > Stainless steel wire guard and mounting bracket supplied as standard > ATEX & IECEx approvals Series YL6S, YA6S, FL6S 16586E00 WebCode WebCode WebCode YL6SA YA6SA FL6SA ATEX / IECEx Zone For use in x x x x Versions 17611E E E00 YL6S GRP Flameproof Combination Signal YA6S GRP Flameproof Audible Signal FL6S GRP Flameproof Visual Signal Selection Table Version 17614E00 GRP Flameproof combination signal db(a) / 5 Joule Note Gas group Rated operational voltage Lens colour IIC 24 V DC red YL6S/C-D-050-R-EN- SF-A-ST amber YL6S/C-D-050-A-EN- SF-A-ST V DC red YL6S/C-F-050-R-EN- SF-A-ST amber YL6S/C-F-050-A-EN- SF-A-ST V AC red YL6S/C-L-050-R-EN- SF-A-ST amber YL6S/C-L-050-A-EN- SF-A-ST V AC red YL6S/C-N-050-R-EN- SF-A-ST amber YL6S/C-N-050-A-EN- SF-A-ST Variations in gas group, flash energy, voltage and lens colour are available, please use the Selection Table The tone table is available on the Internet. Order number Art. no. PS Weight kg

4 & Selection Table Version 17619E00 GRP Flameproof audible signal db(a), 17620E00 GRP Flameproof visual signal - 5 Joule Note Gas group Rated operational voltage Lens colour IIC 24 V DC YA6S/C-D-EN-SF-A- ST V DC YA6S/C-F-EN-SF-A- ST V AC YA6S/C-L-EN-SF-A- ST V AC YA6S/C-N-EN-SF-A- ST IIC 24 V DC red FL6S/C-D-050-R-EN- SF-A-ST amber FL6S/C-D-050-A-EN- SF-A-ST V DC red FL6S/C-F-050-R-EN- SF-A-ST amber FL6S/C-F-050-A-EN- SF-A-ST V AC red FL6S/C-L-050-R-EN- SF-A-ST amber FL6S/C-L-050-A-EN- SF-A-ST V AC red FL6S/C-N-050-R-EN- SF-A-ST amber FL6S/C-N-050-A-EN- SF-A-ST Variations in gas group, flash energy, voltage and lens colour are available, please use the Selection Table The tone table is available on the Internet. Yodalex Super Series Series YL6S, YA6S, FL6S Order number Art. no. PS Weight kg

5 Yodalex Super Series Series YL6S, YA6S, FL6S & Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BAS IEC : 2011 / IEC : 2007 / IEC : 2013 Ex d IIB T* Ta -**... +** C Gb Ex d IIC T* Ta -**... +** C Gb Ex tb IIIC T*** C Ta -**... +** C Db IP66 Europe (ATEX) Gas and dust Certifications and certificates Certificates Design Product variant table Design Product variant table Design Product variant table Baseefa14ATEX0126 EN : 2012 / EN : 2007 / EN : 2009 (IEC : 2013) E II 2 G Ex d IIB T* Ta -**... Ta +** C Gb E II 2 G Ex d IIC T* Ta -**... Ta +** C Gb E II 2 D Ex tb IIIC T*** C Ta -**... +** C Db IP66 IECEx, ATEX YL6S Power and Temperature Max. surface Ambient temperature voltage class temperature range 24 V DC T6 T75 C C 48 V DC T6 T75 C C 115 V AC T6 T77 C C T5 T87 C C 240 V AC T6 T77 C C T5 T87 C C FL6S 5 J 24 V DC T6 T73 C C T5 T88 C C T4 T103 C C 5 J 48 V DC T6 T73 C C T5 T88 C C T4 T103 C C 5 J 115 V AC T5 T83 C C T4 T113 C C 5 J 230 V AC T6 T75 C C T5 T90 C C T4 T105 C C Design YL6S YA6S FL6S Ambient conditions Operating temperature range Certified hazardous area protection temperatures Power and Temperature Max. surface Ambient temperature voltage class temperature range 5 J 24 V DC T5 T95 C C T4 T110 C C 5 J 48 V DC T5 T95 C C T4 T110 C C 5 J 115 V AC T5 T95 C C T4 T110 C C 5 J 230 V AC T5 T95 C C T4 T110 C C YA6S Power and voltage Temperature class 24/48 V DC C 115 V AC C 230 V AC C For further information see the operation manual Max. surface temperature 24/48 V DC C 115 V AC C 230 V AC C For further information see the operation manual Ambient temperature range 24/48 V DC C 115 V AC C 230 V AC C For further information see the operation manual 520

6 & Yodalex Super Series Series YL6S, YA6S, FL6S Design YL6S YA6S FL6S Electrical data Rated operational voltage Current consumption 24 or 48 V DC 115 or 230 V AC 24 or 48 V DC 115 or 230 V AC Operational parameters + / -10 % + / -10 % + / -10 % Line monitoring yes yes yes Acoustic data Volume max. 110 db(a) max. 110 db(a) Volume control 18 db(a) adjustment 18 db(a) adjustment Sound stages 24 / 48 V DC 3 24 / 48 V DC / 230 V AC / 230 V AC 2 24 or 48 V DC 115 or 230 V AC Sound selection via DIL switch via DIL switch Luminous characteristics Light source Xenon flash tube Xenon flash tube Flash energy 5 J 5 J Flash rate 1/s 1/s Light intensity Effective Candela Effective candela seconds candela (cd) (cd) clear Lens colour 24 V DC 600 ma 48 V DC 420 ma 115 V AC 280 ma 230 V AC 115 ma * tone 1 amber, red, green, opal, blue, clear, yellow, magenta 24 V DC 280 ma 48 V DC 250 ma 115 V AC 76 ma 230 V AC 40 ma 24 V DC 320 ma 48 V DC 170 ma 115 V AC 204 ma 230 V AC 75 ma Candela seconds clear amber, red, green, opal, blue, clear, yellow, magenta Mechanical data Material Enclosure glass reinforced polyester glass reinforced polyester glass reinforced polyester Horn and trumpet flame retardant ABS flame retardant ABS Lens cover polycarbonate polycarbonate Wire guard stainless steel stainless steel Assembly parts stainless steel stainless steel stainless steel Bracket stainless steel stainless steel stainless steel Labels polyester foil, adhesive polyester foil, adhesive polyester foil, adhesive Degree of protection IP66 / IP67 acc. to IEC Mounting / Installation Connection 2.5 mm 2 terminals Accessories and Spare Parts Designation Figure Description Art. no. PS Weight kg Xenon tube Replacement xenon tube assembly PCB 15798E00 PCB assembly 24 V DC 5J PCB assembly 48 V DC 5J E00 PCB assembly 110 V AC 5J PCB assembly 230 V AC 5J PCB termination PCB assembly termination E00 521

7 Yodalex Super Series Series YL6S, YA6S, FL6S & Dimensional Drawings (All Dimensions in mm [inches]) Subject to Alterations 105 [4,13] [6,12] 155,50 75 [2,95] Ø9 [ Ø0,35] 117 [4,61] 95 [3,74] 189 [7,44] Ø145 [ Ø5,70] 403 [15,87] 178,50 [7,03] 105 [4,13] [6,12] 155,50 75 [2,95] Ø9 [ Ø0,35] 33 [1,30] 117 [4,61] 95 [3,74] 189 [7,44] Ø145 [ Ø5,70] 263,50 [10,37] 178,50 [7,03] 17150E00 40 [1,57] 105 [4,13] 117 [4,61] 75 [2,95] 189 [7,44] Ø9 [ Ø0,35] 95 [3,74] 178,50 [7,03] 287,50 [11,32] 17149E00 GRP Combination Signal Series YL6S with L-Bracket 17151E00 GRP Audible Signal Series YA6S with L-Bracket GRP Visual Signal Series FL6S with L-Bracket 3 x M6 32 [1,26] 178,50 [7,03] 75 [2,95] 403 [15,87] 3 x M6 33 [1,30] 178,50 [7,03] 75 [2,95] 263,50 [10,37] 32 [1,26] 3 x M6 178,50 [7,03] 148 [5,83] 40 [1,57] Ø145 [ 5,70] Ø 32 [1,26] 75 [2,95] Ø145 [ 5,70] Ø 16919E E00 GRP Combination Signal Series YL6S without L-Bracket 20 [ 0, 79] 117 [4,61] 17148E00 GRP Audible Signal Series YA6S without L-Bracket GRP Visual Signal Series FL6S without L-Bracket 75 [ 2, 95 ] 105 [ 4, 13 ] L-Bracket ø9 [ ø0, 35] 17159E00 522

8 & Audible and Visual Alarms Series FL60, YA60, YL60 Series FL60, YA60, YL60 WebCode WebCode WebCode FL60B YA60A YL60A 15195E00 > Audible and visual alarms Sounder Strobe Sounder/strobe combination > Omnidirectional high output sounder 110 db(a) / 1 m > 32 selectable tones meeting international regulations > Lens available in seven different colours > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > Lens guard and mounting bracket supplied as standard > Telephone initiate option available ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division For use in x x x x For use in x x x x For use in x x x x x x Versions 13974E E E00 FL60 Strobe YA60 Sounder YL60 Sounder/Strobe combination 523

9 Audible and Visual Alarms Series FL60, YA60, YL60 & Selection Table Version Group Flash energy 13974E00 FL60 Strobe, ATEX certification, standard devices Rated operational voltage Lens colour Order number Art. no. PS Weight kg IIB + H 2 5 Joule 24 V DC amber FL60/C/D50/A/EU red FL60/C/D50/R/EU V AC amber FL60/C/L50/A/EU red FL60/C/L50/R/EU V AC amber FL60/C/N50/A/EU red FL60/C/N50/R/EU Selection Table Version Group Rated operational voltage Order number Art. no. PS Weight kg IIB + H 2 24 V DC YA60/C/D/EU V AC YA60/C/L/EU V AC YA60/C/N/EU E00 YA60 Sounder, ATEX certification, standard devices Selection Table Version Group Flash energy Rated operational voltage Lens colour Order number Art. no. PS Weight kg IIB + H 2 5 Joule 24 V DC amber YL60/C/D50/A/EU red YL60/C/D50/R/EU V AC amber YL60/C/L50/A/EU red YL60/C/L50/R/EU V AC amber YL60/C/N50/A/EU red YL60/C/N50/R/EU E00 YL60 Sounder/ Strobe combination, ATEX certification, standard devices Note Variations in gas group, flash energy, voltage and lens colour are available, please use the Selection Table The tone table is available on the Internet. 524

10 & Audible and Visual Alarms Series FL60, YA60, YL60 Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BAS X IIB+H2 Ex d IIB+H2 T4 Gb (Ta = C) Ex tb IIIC T135 C Db IP 66 (Ta = C) Ex d IIB+H2 T6 Gb (Ta = C) Ex tb IIIC T85 C Db IP 66 (Ta = C) Europe (ATEX) Gas and dust Certifications and certificates Certificates Electrical data Rated operational voltage Rated operational current Baseefa 02ATEX0222X IIB+H2 EII 2 G Ex d IIB+H2 T4 Gb (Ta = C) EII 2 D Ex tb IIIC T135 C Db IP 66 (Ta = C) EII 2 G Ex d IIB+H2 T6 Gb (Ta = C) EII 2 D Ex tb IIIC T85 C Db IP 66 (Ta = C) IECEx, ATEX, Brazil (INMETRO), India (PESO), Taiwan (ITRI), USA (UL) 24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters + or -10 % YL60 YA60 24 V DC 570 ma 350 ma 48 V DC 435 ma 300 ma 115 V AC 200 ma 110 ma 230 V AC 100 ma 55 ma Acoustic data Volume Sound selection Luminous characteristics Effective candela Flash energy Flash rate FL60 24 V DC 5 J 220 ma 10 J 500 ma 20 J 1100 ma 48 V DC 5 J 135 ma 10 J 300 ma 20 J 560 ma 115 V AC 5 J 90 ma 10 J 105 ma 20 J 260 ma 230 V AC 5 J 45 ma 10 J 53 ma 20 J 107 ma 110 db(a) / 1 m via DIL-switch FL60 YL60 5 J 5 J Clear lens 30 cd Clear 30 cd Yellow lens 29 cd Yellow 29 cd Amber lens 17 cd Amber 17 cd Red lens 9 cd Red 9 cd Blue lens 6 cd Blue 6 cd Green lens 7 cd Green 7 cd No figures for Magenta lens No figures for Magenta or Opal lens 10 J Clear lens cd 20 J Clear lens 301 cd FL60: 5, 10 or 20 Joule YL60: 5 Joule 60 FPM 525

11 Audible and Visual Alarms Series FL60, YA60, YL60 & Technical Data Ambient conditions Ambient temperature T4: C T6: C Mechanical data Material Enclosure aluminium, seawater resistant Horn ABS, flame retardant Lens cover polycarbonate Fixings stainless steel Mounting bracket mild steel with black polyester powder coat finish; supplied as standard Product label metalised polyester UL certified variants supplied with stainless steel label Degree of protection IP66 IEC NEMA 4X UL 50 Cable entries 2 cable entries, equipped with stopping plug (1x) and dust cap (1x) UL devices: equipped with M20 / 1/2 adapters (2x) Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 75 [2,95] M8 276 [10,87] 75 [2,95] M8 288 [11,34] 75 [2,95] M8 420 [16,54] 145 [5,71] 145 [5,71] 145 [5,71] 13978E E E00 FL60 Strobe YA60 Sounder YL60 Sounder/Strobe combination Accessories and Spare Parts Designation Figure Description Order number Art. no. PS WebCode Cable glands Ex d & Ex e Compound barrier cable gland CMP-20PXSS2K PXSS2KA for all types of unarmoured and braid armour cables (nickel plated brass) Note 15793E00 Ex d & Ex e Compound barrier cable gland for all types of armoured cables (SWA, braided, tape) 15791E00 (nickel plated brass) Approvals of cable entries have to be observed. CMP-20PX2K PX2KA 526

12 & Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS 13989E00 > Intrinsically safe Sounders and Sounder/Strobe combinations > High sound output > 32 selectable tones meeting international regulations > Meets UKOOA/PFEER requirements > Sound selection via DIL switch > Lens of Sounder/Strobe combinations available in six different colours > Monitoring facility > Stainless steel fixings > Flame retardant ABS enclosure > Robust and reliable WebCode WebCode WebCode YL5ISA YL4ISA YO5ISA ATEX Zone For use in x x x x x x WebCode WebCode YO4ISA YO3ISA Selection Table Version Enclosure colour Safety barrier Temperature class Order number Art. no. PS Weight kg red flame (RF) ISC T4 YO3/ISC/T T6 YO3/ISC/T YO3IS Sounder, ATEX certification, standard devices 13995E00 Selection Table Version Enclosure colour Safety barrier Temperature class Order number Art. no. PS Weight kg red normal (RN) ISC T4 YO4/ISC/T T6 YO4/ISC/T YO4IS Sounder, ATEX certification, standard devices 15239E00 527

13 Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS & Selection Table Version Enclosure colour Safety barrier Temperature class Order number Art. no. PS Weight kg red flame (RF) ISC T4 YO5/ISC/T T6 YO5/ISC/T YO5IS Sounder, ATEX certification, standard devices 13996E00 Selection Table Version Enclosure colour Safety barrier Temperature class Lens colour Order number Art. no. PS Weight kg red normal (RN) ISC T4 amber YL4/ISC/T4/A/RN red YL4/ISC/T4/R/RN green YL4/ISC/T4/G/RN opal YL4/ISC/T4/O/RN blue YL4/ISC/T4/B/RN clear YL4/ISC/T4/C/RN YL4IS Sounder/Strobe, ATEX certification, standard devices 15240E00 Selection Table Version Enclosure colour Safety barrier YL5IS Sounder/Strobe, ATEX certification, standard devices Note 13998E00 Temperature class Lens colour Order number Art. no. PS Weight kg red flame (RF) ISC T4 amber YL5/ISC/T4/A/RF Variations in gas group, flash energy, voltage and lens colour are available. Please contact your local sales office for details. The tone table is available on the Internet. red YL5/ISC/T4/R/RF green YL5/ISC/T4/G/RF opal YL5/ISC/T4/O/RF blue YL5/ISC/T4/B/RF clear YL5/ISC/T4/C/RF

14 & Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS Technical Data Explosion protection Europe (ATEX) Gas and dust YO3IS, YO4IS, YO5IS YL4IS, YL5IS BAS02ATEX1190X Baseefa08ATEX0194X Certifications and certificates Certificates Electrical data Rated operational voltage Current consumption Certified input parameters YO*/IS*/T4 YO*/IS*/T6 YL4IS, YL5IS ATEX, India (PESO) E II 1 G Ex ia IIC T4 Ga E II 1 D Ex ia IIIC T190 C Da E II 1 G Ex ia IIC T6 Ga E II 1 D Ex ia IIIC T75 C Da E II 1 G Ex ia IIC T4 Ga E II 1 D Ex ia IIIC T190 C Da V DC Power Certified barrier / Current consumption Sound output db(a)/1 m supply isolator parameters YO5IS YO4IS YO3IS YO5IS YO4IS, YO3IS 24 V DC 28 V / 300 Ω 28 ma 25 ma 25 ma 103 db(a)/1 m 100 db(a)/1 m 18 V DC 28 V / 300 Ω 21 ma 20 ma 19 ma 99 db(a)/1 m 98 db(a)/1 m Power Certified barrier / Current consumption Sound output db(a)/1 m supply isolator parameters tone 1 *) YL5IS, YL4IS YL5IS YL4IS 24 V DC 28 V / 300 Ω 24 ma 100 db(a)/1 m 99 db(a)/1 m 18 V DC 28 V / 300 Ω 33 ma 97 db(a)/1 m 94 db(a)/1 m *) combined supply YO5IS, YO4IS YO3IS U i = 30 V I i = 133 ma P i = 0.7 W C i = 0 L i = 0 Acoustic data Volume YL5IS, YL4IS Independent wiring Combined beacon sounder supply U i = 30 V 30 V 30 V I i = 200 ma 133 ma 133 ma P i = 0.7 W 0.7 W 0.7 W C i = L i = YO3IS, YO4IS, YL4IS: max. 100 db(a) YO5IS, YL5IS: max. 105 db(a) Volume control 15 db(a) adjustment (T4 Models only) Sound stages 2 Sound selection via DIL-switch Luminous characteristics Version YL5IS, YL4IS Light source 8 array LED Flash rate 1/s Lens colour amber, red, green, opal, blue, clear Ambient conditions Operating C temperature range Storage temperature C Max. relative humidity 95 % at 40 C 529

15 Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS & Technical Data Mechanical data Cable entries Material Enclosure Assembly parts Labels Degree of protection Accessories and Spare Parts 1 x M20 ABS, flame retardant stainless steel fixings polyester foil, adhesive YO3IS, YO4IS, YL4IS: IP55 acc. IEC YO5IS, YL5IS: IP56 acc. IEC Designation Figure Description Order number Art. no. PS WebCode Safety barrier single channel 9001/ A dual channel 9002/ A 02326E00 Galvanic isolator single channel 9176/ s A dual channel 9176/ s A Cabel gland 12530E /8-M mm 2 50 pieces (delivery lot *) ) 8161/8-M A 13027E00 *) Purchase order quantity in [pieces], the delivery quantity is automatically rounded to the delivery lot. 530

16 & Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 85 [3,35] 9 [0,35] 118 [4,65] 102 [4,02] 89 [3,50] 128 [5,04] 9 [0,35] 169 [6,65] 153 [6,02] 136 [5,35] M20 89 [3,50] 18 [0,71] ø 6 [ø 0,24] 136 [5,35] ø 8 [ø 0,32] M20 25 [0,98] YO3 Sounder 14001E00 YO5 Sounder 14011E00 91,50 [3,60] 82,50 [ 3,25] 183 [7,20] 13999E00 YO4 Sounder 128 [5,04] 88 [3,46] 169 [6,65] 153 [6,02] 136 [5,35] 88 [3,46] 91,50 [3,60] 82,50 [3,25] 136 [5,35] 194,50 [7,66] ø 8 [ø 0,32] 274,50 [10,81] M20 9 [0,35] 25 [0,98] YL5 Sounder/Strobe combination 14002E00 YL4 Sounder/Strobe combination 16643E00 Note Non-Ex versions can be found in the catalogue Audible & Visual Signals. 531

17 Hazardous Area Audible Signal db(a) Series YA11 & Series YA E00 > Max sound output 100 db(a) / 1 m > IP66, NEMA 4X rated as standard > Single stage alarm > 32 sound tones available meeting international regulations > Low profile (28 mm) light weight aluminium enclosure > 3 metre (118 ) 2 core pre wired cable fitted and prepared ready for installation > Panel sealing gasket and fixings provided > Low current consumption > High performance red paint finish as standard WebCode YA11A ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division For use in x x For use in x x For use in x x x x Selection Table Version Enclosure colour Rated operational voltage Order number Art. no. PS Weight kg YA11 Sounder, standard devices red standard (R) V DC YA11/1-D-..-RN Note The tone table is available on the Internet. Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BAS X Ex na IIC T4 Gc Ex tc IIIC T90 C Dc IP66 (-40 C (Ta (+70 C) Europe (ATEX) Gas and dust Customer must specify the required sound tone at the point of ordering. The sound tone cannot be changed by the customer. There are 32 tones available, please see the order number supplement below, for example if tone 18 is required please use the order number YA11/1-D-18-RN Baseefa 10 ATEX 0252X E II 3 GD Ex na IIC T4 Gc Ex tc IIIC T90 C Dc (-40 C ( Ta ( +70 C) Certifications and certificates Certificate IECEx, ATEX, Canada ( CUL), USA (UL) Ship approval Lloyds Register Electrical data Rated operational voltage 24 V DC ( V DC) Current consumption 70 ma Acoustic data Volume 100 db(a) / 1 m Ambient conditions Operating temperature range C Mechanical data Material Enclosure aluminium / ABS Assembly parts stainless steel fixings and foam sealing gasket Degree of protection IP66, NEMA 4X 532

18 & Technical Data Mounting / Installation Assembly Hazardous Area Audible Signal db(a) Series YA11 3 metre (118 ) 2 core pre wired cable fitted and prepared ready for installation to ensure the integrity of seal between the sounder and panel is maintained, the neoprene sponge gasket should be fitted and a torque value of 2.2 to 2.6 Nm (19.5 to 23.0 lbs ins) applied to each screw and nut panel mount via 6 holes on 124 mm (4.9 ) PCD at 60 spacing Panel cut out 109 mm (4.3 ) panel sealing gasket supplied mounting hardware supplied screws are designed to fit a panel thickness of 4 mm max. Tone Table Tone no. Version Frequency Repetition rate (sec) Special application Tone 01 Alternate two-tone Fire alarms - Level crossing Tone 02 Alternate two-tone Security alarms Tone 03 Alternate fast two-tone Increased urgency - Level crossing Tone 04 Alternate fast two-tone Security deterrent Tone 05 Alternate two-tone /0.1 AFNOR, France Tone 06 Alternate two-tone Tone 07 Alternate very fast two-tone Tone 08 Alternate very fast two-tone Tone 09 Alternate two-tone Turn out, Sweden Tone 10 Continuous note 700 All-clear, Sweden Tone 11 Continuous note 1000 Tone 12 Continuous note 1000 Tone 13 Continuous note 2300 Tone 14 Continuous note 440 Tone 15 Interrupted tone Tone 16 Interrupted tone AS2220, Australia Tone 17 Interrupted tone Tone 18 Interrupted tone Tone 19 Interrupted tone Tone 20 Interrupted tone 700 6/12 Pre-vital message, Sweden Tone 21 Interrupted tone Tone 22 Interrupted tone Air-raid alarm, Sweden Tone 23 Interrupted tone Local warning, Sweden Tone 24 Interrupted tone /0.3 Industrial alarm, Germany Tone 25 Interrupted, fast, rising volume Tone 26 Fast siren Tone 27 Rising constant, fall /40/10 Industrial alarm, Germany Tone 28 ISO 8201 Evacuation As standard International evacuation alarm Tone 29 Fast whoop Tone 30 Slow whoop Evacuation, The Netherlands Tone 31 Reverse sweep Evacuation, Germany Tone 32 Siren Accessories and Spare Parts Designation Description Art. no. PS Weight kg Replacement installation kit gasket, screws, nuts, locking devices and washers Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations X ø [ø 5,81] ø 1 24 [ø 4,88] 65 [2,56] ø 10 5 [ø 4,13] 36 [1,42] 14850E00 X = 6 x holes dia 5.3 mm (0.2") and c'bored 10.2 mm (0.4") equispaced on a 124 mm (4.9") PCD 533

19 Flameproof Audible Signal 115 db(a) Series YA90 & Series YA90 WebCode YA90A 13912E00 > Max sound output 115 db(a) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light weight glass reinforced polyester (GRP) Ex enclosure > Sound selection via 5 way DIL switch > Adjustable stainless steel ratchet bracket providing positive setting > Enclosure finished in red high performance paint with ABS flare > Monitoring facility (DC voltages only) > Dual 20 mm gland entries as standard ATEX / IECEx NEC 500 Class I Class II Class III Zone Division For use in x x x x For use in x Technical Data Explosion protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust North America (culus & ULc listed) Gas and dust EAC (TR) Gas and dust Certifications and certificates Certificates YA90/B versions: YA90/C versions: YA90/B+C versions: YA90/B versions: YA90/C versions: YA90/B+C versions: YA90/B versions: YA90/C versions: YA90/B+C versions: YA90/B versions: YA90/C versions: YA90/B+C versions: YA90/B+C versions: YA90/B versions: YA90/C versions: TC RU C-DE.AA71.B YA90/B versions: YA90/C versions: IECEx BAS X IECEx BAS X EN :2009, EN : , EN :2008 Ex d IIB T6 Ta ºC Gb Ex d IIC T6 Ta ºC Gb Ex tb IIIC T85ºC Ta ºC Db IP66 Baseefa 08 ATEX 0191 X Baseefa 08 ATEX 0189 X EN :2009, EN :2007, EN :2009 E II 2 G Ex d IIB T6 Ta ºC Gb E II 2 G Ex d IIC T6 Ta ºC Gb E II 2 D Ex tb IIIC T85ºC Ta ºC Db IP66 E USL: UL 464 / ISA CNL: CAN/ULC-S525-07, Edition / A C22.2 No. 213 USL, CNL - Class I, Div. 2, Groups C and D Hazardous Locations Operating temperature ºC Audible signal appliance, fire alarm service private mode USL, CNL - Class I, Div. 2, Groups A, B, C and D Hazardous Locations Operating temperature ºC Audible signal appliance, fire alarm service private mode 1 Ex d IIB T6 (Tamb -60 C C ) Gb X Ex tb IIIC T85 C Db X 1 Ex d IIC T6 (Tamb -60 C C ) Gb X Ex tb IIIC T85 C Db X IECEx, ATEX, Brazil (INMETRO), China (China-Ex), India (PESO), Korea (KGs), Kazakhstan (TR), North America (culus, ULc), Russia (TR), Belarus (TR) 534

20 & Technical Data Electrical data Rated operational voltage Rated operational current 24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters + or -10 % 24 V DC 300 ma 48 V DC 160 ma 115 V AC 80 ma 230 V AC 45 ma Flameproof Audible Signal 115 db(a) Series YA90 UL calculate the current using RMS Root mean square which gives the following measurement and is the figure reported on UL variant product labels: Acoustic data Volume Alarm stages Sound selection Sound signal selection Ambient conditions Ambient temperature 24 V DC 500 ma 48 V DC not available UL certified variants 115 V AC 130 ma 230 V AC 90 ma 115 db(a) / 1 m Sound output for products gas groups IIC 2 stage alarm via DIL switch 32 (see table Sound Tone Selection) All sounders have 32 sound signal selections. From the 32 sound signals, any signal may be chosen as the first stage alarm and any signal for the second stage alarm. Sound output level and current consumption depends upon the signal selected. ATEX/IECEx variants 24/48 V DC C 115 V AC C 230 V AC C culus & ULC listed C Max. relative humidity 95 % at 40 C Mechanical data Material Enclosure GRP Horn ABS Flame retardant Fixings Screws - A4-80 Bracket Stainless steel DIN EN / AISI 316L Degree of protection IP66 BS EN NEMA 4X UL 50 Enclosure entries 2 x M20 cable entries equipped with 1 x stopping plug & 1 x dust cover UL Product variants supplied with 2 x M20 / 1/2 adaptors Mounting / Installation Assembly stainless steel mounting bracket provided, holes to suit M6, pitch 60 mm 535

21 Flameproof Audible Signal 115 db(a) Series YA90 & Selection Table Version Gasgruppe Rated operational voltage YA90 Sounder, ATEX & IECEx certification, standard devices YA90 Sounder, North America culus & ULc listed, standard devices YA90 Sounder, EAC certification, standard devices Note Order number Art. no. PS Weight kg IIC 24 V DC YA90/C-D-EN-RN-ST V AC YA90/C-L-EN-RN-ST V AC YA90/C-N-EN-RN-ST A, B, C & D 24 V DC YA90/C-D-UL-RN-ST V AC YA90/C-L-UL-RN-ST V AC YA90/C-N-UL-RN-ST IIC 24 V DC YA90/C-D-RU-RN-ST V AC YA90/C-L-RU-RN-ST V AC YA90/C-N-RU-RN-ST Variations in gas group, voltage and certification are available Tag labels can be added, please contact your local sales office for more details Type Code Variant Option Code YA90 / RN - ST Gas group ATEX / IECEx products culus listed products IIB C, D Groups B IIC A, B, C, D Groups C C Rated operational voltage 24 V DC D 48 V DC F 115 V AC L 230 V AC N Certification ATEX & IECEx EN culus & ULc listed UL EAC (TR) RU Body Colour Red RN Specification Standard ST Options None 00 Tag label TL Duty label DL Tag & Duty label DT Activation Standard 00 Telephone TI Local certification Standard 00 INMETRO IN PESO PE KCs KC CQST CQ 536

22 & Flameproof Audible Signal 115 db(a) Series YA90 Accessories and Spare Parts Designation Figure Description Order number Art. no. PS WebCode Cable glands Ex d & Ex e Compound barrier cable gland for all types of unarmoured and braid armour cables (nickel plated brass) CMP-20PXSS2K PXSS2KA 15793E E00 Ex d & Ex e Compound barrier cable gland for all types of armoured cables (SWA, braided, tape) (nickel plated brass) CMP-20PX2K PX2KA Note Approvals of cable entries have to be observed. Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 325 [12,80] ø210 [ø 8 27] 143,50 [5,65] 30 [1,18] ø 7 [ø 0,28] 181 ø 12,7 [ø 0,50] [ 7,13] 60 [2,36] 13971E00 537

23 Hazardous Area Loudspeaker - 25, 15 or 8 W Series 8494 & > Max. sound pressure level 121 db(a) > Extreme temperature range C > Degree of protection IP66 & IP67 > Antistatic polyamid enclosure > Stainless steel fixing > Ex e connection chamber > Spring clamp terminals > Corrosion resistant device Series E00 WebCode 8494A ATEX / IECEx NEC 505 NEC 506 Class I Zone Zone For use in x x x x For use in x Selection Table Version Group Flare size Hazardous area loudspeaker - 25 Watt Series 8494, standard devices Watt options Impedance / Transformer Order number Art. no. PS Weight kg IIC short 25 W 8 Ω 8494/C-S-EN-ST Ω 8494/C-S-EN-ST W V 8494/C-S-EN-ST tappings line transformer long 25 W 8 Ω 8494/C-L-EN-ST Ω 8494/C-L-EN-ST W + tappings 100 V line transformer Order Number Supplement Hazardous area Variations Type code: please fill in fields loudspeaker Series 8494, Gas group acc. to specification IIB + H2 IIC Flare short long Certification ATEX / IECEx / NEC/CEC 505 Company specification standard B C S L EN ST Options 15 W 8 Ω W 20 Ω W 8 Ω W 20 Ω W 100 V line transformer W 100 V line transformer 15 8 W 100 V line transformer W 70 V line transformer W 70 V line transformer 18 8 W 70 V line transformer 19 Local certification standard /C-L-EN-ST Order Number 8494/ _ - _ - _ - _ - _ - _ 538

24 & Technical Data Explosion protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust North America (NEC, CEC) Gas and dust Certifications and certificates Certificates Electrical data Device version Line options Impedance Acoustic data Short flare version Hazardous Area Loudspeaker - 25, 15 or 8 W Series 8494 IIB + H2, IIC IECEx PRE X IIB + H2 IIC IIB + H2, IIC IIB + H2 IIC IECEx, ATEX, Canada (clcus), USA (clcus) 100 or 70 V 8 or 20 Ω II 2 G Ex d e mb IIB+H2 T4 (-50 C ( Ta ( +60 C) Gb IP66/67 II 2 D Ex tb IIIC T105 C (-50 C ( Ta ( +60 C) Db IP66/67 II 2 G Ex d e mb IIC T4 (-50 C ( Ta ( +60 C) Gb IP66/67 II 2 D Ex tb IIIC T105 C (-50 C ( Ta ( +60 C) Db IP66/67 PRE 14 ATEX 5555X E II 2 G Ex d e mb IIB+H2 T4 (-50 C ( Ta ( +60 C) Gb IP66/67 E II 2 D Ex tb IIIC T105 C (-50 C ( Ta ( +60 C) Db IP66/67 E II 2 G Ex d e mb IIC T4 (-50 C ( Ta ( +60 C) Gb IP66/67 E II 2 D Ex tb IIIC T105 C (-50 C ( Ta ( +60 C) Db IP66/67 IIB + H2, IIC CAN/A-C22.2 No :2011 & UL :2009, CAN/A-C22.2 No :2011 & UL :2009, A-C22.2 No :2012 & UL 60065:2007 IIB + H2 IIC Class 1 Zone 1 AEx d IIB+H2 T4 Gb -50 C ( Ta ( +50 C, IP 66/IP67 Class 1 Zone 1 AEx d IIC T4 Gb -50 C ( Ta ( +50 C, IP 66/IP /.-S IIB + H2 IIC Sound pressure level at 1 W 105 db(a) 1 W / 1m 102 db(a) 1 W / 1m Sound pressure level at 25 W 118 db(a) 1m 115 db(a) 1m Frequency range Hz Hz Dispersion (-6 db) 1 khz khz Directivity factor at 1 khz Sound pressure level vs frequency at 1 W db Hz K 2K 5K 10K 20K 16888E00 539

25 Hazardous Area Loudspeaker - 25, 15 or 8 W Series 8494 & Technical Data Acoustic data Long flare version 8494/.-L IIB + H2 IIC Sound pressure level at 1 W 109 db(a) 1 W / 1m 106 db(a) 1 W / 1m Sound pressure level at 25 W 121 db(a) / 1m 118 db(a) / 1m Frequency range Hz Hz Dispersion (-6 db) 1 khz khz Directivity factor at 1 khz Sound pressure level vs db frequency at 1 W Hz K 2K 5K 10K 20K Ambient conditions Operating C temperature range Mechanical data Cable entries 2 x M20 supplied with 2 x dust cover Material Enclosure Anti static polyamid Flare Anti static polyamid Bracket Anti static polyamid supplied as standard Labels Polyester foil External fixings Stainless steel Degree of protection IP66 / IP67 acc. to IEC Mounting / Installation Mounting via bracket Connection 4 mm spring clamp terminals 50 pieces Accessories and Spare Parts Designation Figure Description Order number Art. no. PS Web- Code Cable gland 8161/7-M /7-M A mm 2 (delivery lot *) ) E E00 Stopping plug 04840E /3-M /3-M20 1 piece 100 pieces 8290/3-M A 8290/3-M A Bracket stainless steel 1 piece 01789E00 *) Purchase order quantity in [pieces], the delivery quantity is automatically rounded to the delivery lot. 540

26 & Hazardous Area Loudspeaker - 25, 15 or 8 W Series 8494 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations A 170 [6,69] 188 [ 7,40 ] 30 [1,18] Ø 7 [ Ø 0,28] ø 10,5 [ø 0,41] 207 [8,15] X X 120 [4,72] 144,50 [5,69] A 144 [5,67] Hazardous Area Loudspeaker - Short Flare Series 8494 Bracket (A) supplied as standard 43 [1,69] 17003E00 A 170 [6,69] 275 [10,83] 30 [1,18] Ø 7 [ Ø 0,28] ø 10,5 [ø 0,41] 348 ±3 [13,70±0,12] X X 120 [4,72] 144,50 [5,69] A 200 [7,87] Hazardous Area Loudspeaker - Long Flare Series 8494 Bracket (A) supplied as standard 43 [1,69] 16814E00 541

27 Signal Horn 105 db(a) Series 8491/1, 8491/2 & > Fixed signal tone > Volume max. 105 db(a) / 1 m > Installation by means of angle mounting > AC and DC versions Signal Horn Series 8491/1 > With trumpet and connection cable Signal Horn Series 8491/2 Series 8491/1, 8491/ E00 > Compact design with connection chamber and cable gland WebCode 8491A ATEX Zone /1: For use in x x 8491/2: For use in x x x x Selection Table Version Rated operational voltage Order number Art. no. PS Weight 24 V AC, 50 Hz 8491/ V AC, 50 Hz 8491/ V AC, 50 / 60 Hz 8491/ V AC, 60 Hz 230 V AC, 50 Hz 8491/ V DC 8491/ kg 00446E E V AC, 50 Hz 8491/ V AC, 50 / 60 Hz 8491/ V AC, 60 Hz V AC, 50 Hz 8491/ V AC, 50 Hz 8491/ V DC 8491/

28 & Signal Horn 105 db(a) Series 8491/1, 8491/2 Technical Data Explosion protection Europe (ATEX) Gas and dust Certifications and certificates Certificates 8491/1 8491/2 EN :2012 EN :2009 EN :2012 EN :2007 EN :2009 EN :2009 E II 2 G Ex e mb IIC T5 Gb E II 2 G Ex mb IIC T5 Gb - - E II 2 D Ex tb IIIC T70 C Db IP65 ATEX, China (China-Ex), Kazakhstan (TR), Russia (TR), Serbia (SRPS), Ukraine (TR), Belarus (TR) ATEX, China (China-Ex), Kazakhstan (TR), Russia (TR), Serbia (SRPS), Ukraine (TR), Belarus (TR) Material Enclosure PC/ABS, black PC/ABS, black Degree of protection IP55 IP65 Connection type LAPPTHERM 145, 2 x 0.75 mm 2, 3 m screw terminal in the connection chamber max. connection cross-section 2.5 mm 2 1 x M16 cable gland mm cable dia. range Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Signal horn with trumpet Series 8491/ E00 Signal horn, compact design with connection chamber Series 8491/ E00 543

29 GRP Flameproof Visual Signal 5 Joule Series FX15 & Series FX E00 > Suitable for offshore / onshore & harsh environments > Corrosion resistant light-weight enclosure made of glass-fibre reinforced polyester (GRP) > Stainless steel and fixings and guard > High ingress protection IP66 & IP67 > Extreme temperature range C > Flexible mounting options > Light enhancing lens design WebCode FX15A ATEX IECEx Zone For use in x x x x Selection Table Version Group Rated operational voltage ATEX & IECEx standard variants Note Lens colour Order number Art. no. PS Weight kg IIC 24 V DC amber FX15/C-D-050-A-EN-SF-A blue FX15/C-D-050-B-EN-SF-A clear FX15/C-D-050-C-EN-SF-A green FX15/C-D-050-G-EN-SF-A magenta FX15/C-D-050-M-EN-SF-A opal FX15/C-D-050-O-EN-SF-A red FX15/C-D-050-R-EN-SF-A yellow FX15/C-D-050-Y-EN-SF-A V DC amber FX15/C-F-050-A-EN-SF-A blue FX15/C-F-050-B-EN-SF-A clear FX15/C-F-050-C-EN-SF-A green FX15/C-F-050-G-EN-SF-A magenta FX15/C-F-050-M-EN-SF-A opal FX15/C-F-050-O-EN-SF-A red FX15/C-F-050-R-EN-SF-A yellow FX15/C-F-050-Y-EN-SF-A V AC amber FX15/C-L-050-A-EN-SF-A blue FX15/C-L-050-B-EN-SF-A clear FX15/C-L-050-C-EN-SF-A green FX15/C-L-050-G-EN-SF-A magenta FX15/C-L-050-M-EN-SF-A opal FX15/C-L-050-O-EN-SF-A red FX15/C-L-050-R-EN-SF-A yellow FX15/C-L-050-Y-EN-SF-A V AC amber FX15/C-N-050-A-EN-SF-A blue FX15/C-N-050-B-EN-SF-A clear FX15/C-N-050-C-EN-SF-A green FX15/C-N-050-G-EN-SF-A magenta FX15/C-N-050-M-EN-SF-A opal FX15/C-N-050-O-EN-SF-A red FX15/C-N-050-R-EN-SF-A yellow FX15/C-N-050-Y-EN-SF-A FX15 Beacons are supplied without a bracket. These must be ordered separately (see accessories table). 544

30 & GRP Flameproof Visual Signal 5 Joule Series FX15 Technical Data Explosion protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust Product variant table Certifications and certificates Certificates IIB IECEx BAS X IIC IECEx BAS IIB, IIC IEC : 2011 / IEC : / IEC : 2008 IIB Ex d IIB T* Gb (Ta = -60 +** C) Ex tb IIIC T*** C Db IP 66 (Ta = -60 +** C) IIC Ex d IIC T* Gb (Ta = -60 +** C) Ex tb IIIC T*** C Db IP 66 (Ta = -60 +** C) * temperature class on the table IIB Baseefa13ATEX0007X IIC Baseefa13ATEX0006 IIB, IIC EN : 2012 / EN : 2007 / EN : 2009 IIB EII 2 G Ex d IIB T* Gb (Ta = -60 +** C) EII 2 D Ex tb IIIC T*** C Db IP 66 (Ta = -60 +** C) IIC EII 2 G Ex d IIC T* Gb (Ta = -60 +** C) EII 2 D Ex tb IIIC T*** C Db IP 66 (Ta = -60 +** C) * temperature class on the table Power and voltage 5 J 24 V DC 5 J 48 V DC 5 J 115 V AC 5 J 230 V AC IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (TR), Russia (TR), Belarus (TR) Electrical data Rated operational voltage 24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters +/-10 % Rated operational current 24 V DC 300 ma 48 V DC 185 ma 115 V AC 140 ma 230 V AC 75 ma Luminous characteristics Effective candela Candela seconds Clear lens 9.96 cds 49 cd Flash energy 5 J Flash rate 1 per second Operating temperature range 24 & 48 V DC C 115 V AC C 230 V AC C Mechanical data Material Enclosure GRP Lens cover polycarbonate Wire guard stainless steel Degree of protection IP66 & IP67 IEC Cable entries 3 x M20, product supplied with 3 x dust cover Weight 2.4 kg Temperature class Max. surface temperature Ambient temperature range T6 T73 C C T5 T88 C C T4 T103 C C T6 T73 C C T5 T88 C C T4 T103 C C T5 T83 C C T4 T113 C C T6 T75 C C T5 T90 C C T4 T105 C C 545

31 GRP Flameproof Visual Signal 5 Joule Series FX15 & Accessories and Spare Parts Designation Figure Description Art. no. PS WebCode Mounting brackets Stainless steel L-bracket - see dimensional drawings Cable glands 15795E E00 Stainless steel backstrap mounting bracket - see dimensional drawings Ex d & Ex e Compound barrier cable gland for all types of unarmoured and braid armour cables (nickel plated brass) PXSS2KA 15793E00 Ex d & Ex e Compound barrier cable gland for all types of armoured cables (SWA, braided, tape) (nickel plated brass) PX2KA Xenon tube 15791E00 Replacement xenon tube assembly PCB PCB termination 15798E E00 PCB assembly 24 V DC 5J PCB assembly 48 V DC 5J PCB assembly 110 V AC 5J PCB assembly 230 V AC 5J PCB assembly termination Flange 15785E00 Flange assembly standard clear E00 546

32 & GRP Flameproof Visual Signal 5 Joule Series FX15 Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 148 mm / 5.83 " 105 mm / 4.13 " 78 mm / 3.07 " 87 mm / 3.43 " 164 mm / " 78 mm / 3.07 " 152 mm / 5.98 " ø 8,50 mm / ø 0.33 " 239 mm / 9.41 " 245 mm / 9.65 " 265 mm / " 253 mm / 9.96 " 137 mm / 5.39 " 15739E E E00 FX15 Beacon FX15 Beacon with L bracket FX15 Beacon with backstrap bracket 78 mm / 3.07 " ø 8,50 mm ø 0.33 " 75 mm / 2.95 " ø9 mm ø0.35 " 180 mm / 7.09 " 152 mm / 5.98 " 25 mm 0.98 " 180 mm / 7.09 " 28 mm 1.10 " 15743E E00 Backstrap bracket 20 mm 0.79 " 75 mm / 2.95 " 87 mm / 3.43 " 105 mm / 4.13 " ø9 mm ø0.35 " 15742E E00 L-shaped bracket 547

33 Flashing Beacon and Continuous Beacon Series 6161 & > Robust, seawater resistant aluminium enclosure > Flashing frequency 1 Hz > Flashing energy 5 Joules > Integrated Ex e connection chamber > Available with signal yellow, red, orange, green, blue and clear light dome > Steady beacon in LED technology > Extreme temperature range C Series E00 WebCode 6161A ATEX / IECEx Zone For use in x x x x Selection Table Version Nominal voltage Internal fuse Order number Art. no. PS Weight 6161/2 Flashing Beacon 6161/3 Continuous Beacon 230 V AC, Hz V AC, Hz V AC, Hz and V DC kg 315 mat 6161/ mat 6161/ / V DC 6161/ V AC, Hz 24 V AC / DC, 0 Hz, Hz 200 mat 6161/ mat 6161/ Order Number Supplement Colour of glass signal yellow 6161/ clear 6161/ red 6161/ blue 6161/ green 6161/ orange 6161/ Note The optical beacons are supplied without attachment materials and wire guard. These must be ordered separately! 548

34 & Flashing Beacon and Continuous Beacon Series 6161 Technical Data Version 6161/2 Flashing Beacon 6161/3 Continuous Beacon Explosion protection Global (IECEx) Gas and dust IECEx LCI X IECEx LCI X Ex d e IIC T* Gb -40 C T amb +** C Ex d e IIC T* Gb -40 C T amb +** C Ex tb IIIC T* Db IP66-40 C T amb +** C Ex tb IIIC T* Db IP66-40 C T amb +** C IEC : 2011 IEC : IEC : IEC : 2008 ** see ambient conditions for the temperature class IEC : 2011 IEC : IEC : IEC : 2008 ** see ambient conditions for the temperature class Europe (ATEX) Gas and dust LCIE 02 ATEX 6062 X LCIE 02 ATEX 6062 X E II 2 G Ex d e IIC T* Gb -40 C T amb +** C E II 2 G Ex d e IIC T* Gb -40 C T amb +** C E II 2 D Ex tb IIIC T* Db IP66-40 C T amb +** C E II 2 D Ex tb IIIC T* Db IP66-40 C T amb +** C EN : 2012 EN : 2007 EN : 2007 EN : 2009 Conditions of certificate: If wire guard is not installed, the apparatus shall be submitted to low mechanical impact only. EN : 2012 EN : 2007 EN : 2007 EN : 2009 Conditions of certificate: If wire guard is not installed, the apparatus shall be submitted to low mechanical impact only. ** see ambient conditions for the temperature class ** see ambient conditions for the temperature class Certifications and certificates Certificates IECEx, ATEX, China (China-Ex) IECEx, ATEX, China (China-Ex) Ship approval GL Back-up fuse Rated values 4 AT (Fuse slow-blow or automatic circuit breaker C characteristic) V AC Hz A V AC Hz 0.11 A 230 V AC Hz 0.08 A V DC A V DC A Flashing energy 5 Joules Flashing frequency 1Hz Ambient temperature ** Temperature Class ** Temperature Class Type T amb Gas Dust 6121/2 +40 C T6 T85 C +50 C T5 T100 C 4 AT (Fuse slow-blow or automatic circuit breaker C characteristic) 24 V AC / DC 0 Hz, Hz 0.12 A 230 V AC Hz 0.02 A Type T amb Gas Dust 6121/3 +40 C T6 T65 C +50 C T6 T75 C Degree of protection IP66 according to IEC/EN Protection class I (internal and external PE connection terminal according to IEC/EN 60598) Material Enclosure aluminium alloy copper-free, yellow/black powder-coated Light dome polycarbonate, prismatic Special lock Ex d enclosure; M4 hexagon socket stud Cable entries 1 x M20 x 1.5 stopping plug 1 x M20 x 1.5 cable gland metal cable gland on request Connection type screw terminal block, 3-pole 549

35 Flashing Beacon and Continuous Beacon Series 6161 & Accessories and Spare Parts Designation Figure Description Art. no. PS Weight Mounting plate Pipe clamp 04279E00 material: stainless steel, includes mounting screws, for wall or floor mounting material: stainless steel includes mounting screws R 1 1 / 4 kg E00 R 1 1 / 2 R Ceiling or wall-mounting bracket material: stainless steel includes mounting screws E00 Wire guard material: stainless steel E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Optical beacon 6161 Mounting accessories 09345E00 106, E E E00 Ceiling and wall-mounting bracket Pipe clamp Mounting plate 550

36 & Signal Beacon - LED Series 6162 Series 6162 WebCode 6162A 06147E00 > Versions rotating mirror beacon rotating beacon beacon with double flash (9+5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seewater resistant aluminium enclosure with glass dome > Integrated Ex e connection chamber > Glass dome available in: signal yellow, red, orange and blue respectively clear > Available with 20 W / 35 W halogen bulb or as LED-continuous beacon / LED-rotating beacon ATEX / IECEx Zone For use in x x x x Technical Data Explosion protection Global (IECEx) Gas and dust IECEx PTB Ex d e llc T3... T6 Gb* Ex tb lllc T80 C... T160 C Db* Europe (ATEX) Gas and dust PTB 06 ATEX 1037 E ll 2 G Ex d e llc T3... T6 Gb* Certifications and certificates Certificates Rated operational voltage Lamp wattage Rotation speed E ll 2 D Ex tb lllc T80 C... T160 C Db* * Temperature classes are dependent on lamp wattage (see selection table) IECEx, ATEX, Kazakhstan (TR), Russia (TR), Serbia (SRPS), Ukraine (TR), Belarus (TR) see selection table see selection table rotating mirror beacon: 180 rpm rotating beacon: 60 rpm Ambient temperature see selection table Degree of protection IP66 Protection class I (acc. to IEC/EN 60598) Material Enclosure aluminium powder coated, seawater resistant Light dome glass, resistant to thermal shocks Cable entries 1 x M20 x 1.5 (d mm) 1 x M20 x 1.5 stopping plug metal cable gland on request Connection cross-section L1, N, PE 2.5 mm 2 finely-stranded 4 mm 2 solid 551

37 Signal Beacon - LED Series 6162 & Selection Table Version Rated operational voltage Lamp wattage Temperature class Max. surface temperature Max. ambient temperature Order number Art. no. PS Weight 06128E00 Rotating mirror beacon Rotating beacon 05759E00 24 V AC / DC, Hz 115 V AC, Hz 230 V AC, Hz 24 V AC / DC, Hz 115 V AC, Hz 230 V AC, Hz 20 W T4 T4 35 W T3 T3 35 W T3 T3 20 W T4 T4 35 W T3 T3 20 W T6 T5 35 W T4 T4 35 W T4 T4 20 W T6 T5 35 W T4 T4 24 V DC J T5 T5 115 V AC, Hz 230 V AC, Hz J T5 T J T5 T5 105 C 115 C 150 C 160 C 150 C 160 C 105 C 115 C 150 C 160 C 80 C 90 C 105 C 115 C 105 C 115 C 80 C 90 C 105 C 115 C 85 C 95 C 90 C 100 C 85 C 95 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C kg 6162/ / / / / / / / / / / / / E00 Beacon with double flash 24 V AC / DC (± 15 %), Hz V AC, Hz V AC, Hz 15 J T6 T6 15 J T5 T4 15 J T6 T6 75 C 75 C 95 C 105 C 80 C 80 C 40 C 50 C 40 C 50 C 40 C 50 C 6162/ / / E00 Flashing beacon Order Number Supplement Colour of glass signal yellow 6162/ clear 6162/ red 6162/ blue 6162/ orange 6162/ Note The optical beacons are supplied without mounting accessories and wire guard. These must be ordered separately! 552

38 & Signal Beacon - LED Series 6162 Selection Table Version Colour of glass Rated operational voltage Lamp wattage Temperature class Max. surface temperature Max. ambient temperature Order number Art. no. PS Weight signal yellow 24 V DC 5 W T6 T6 T V AC, Hz 5 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C kg 6162/ / E00 LED-continuous beacon 12629E00 LED-continuous beacon red 24 V DC 5 W T6 T6 T V AC, Hz 5 W T6 T6 T5 orange 24 V DC 5 W T6 T6 T V AC, Hz 5 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C 40 C 50 C 60 C 40 C 50 C 60 C 6162/ / / / E00 LED-continuous beacon signal yellow 24 V DC 3.6 W T6 T6 T V AC, Hz 3.6 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C 6162/ / E00 LEDrotating beacon red 24 V DC 3.6 W T6 T6 T V AC, Hz 3.6 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C 6162/ / E00 LEDrotating beacon 12696E00 LEDrotating beacon Note orange 24 V DC 3.6 W T6 T6 T V AC, Hz 3.6 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C The optical beacons are supplied without mounting accessories and wire guard. These must be ordered separately! 6162/ /

39 Signal Beacon - LED Series 6162 & Accessories and Spare Parts Designation Figure Description Art. no. PS Weight kg Halogen lamp G W / 12 V 2 pc W / 24 V 2 pc E00 35 W / 12 V 2 pc W / 24 V 2 pc Mounting plate Pipe clamp 04279E00 material: stainless steel, includes mounting screws, for wall or floor mounting R 1 1 / 4 R 1 1 / 2 R Mounting bracket 04223E00 material: stainless steel, includes mounting screws Wire guard 04281E00 material: stainless steel, includes mounting screws E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 336 X , ,50 M6 Ø 210 Ø X 04282E00 Signal beacon Series 6162 Mounting accessories Y Y , ¼" (Ø 42) 1½" (Ø 48) 2" (Ø 60) 1¼" ½" " , E E E00 Mounting bracket Pipe clamp Mounting plate 554

40 & Instrinsically Safe LED Visual Flashing or Status Signal Series FD40IS, SD40IS > 8 LED array flashing or status beacon > High light intensity > Long life LED design > Lens available in six different colours > Flame retardant ABS enclosure > Up to 4 modules in any combination of colours Series FD40IS, SD40IS 13913E00 WebCode FD_SD40ISA ATEX Zone For use in x x x x x x Selection Table Version Base colour Rated operational voltage Instrinsically Safe LED Visual Flashing Signal FD40IS signal, ATEX certification, standard single module devices Instrinsically Safe LED Visual Status Signal SD40IS signal, ATEX certification, standard single module devices Note red normal (RN) red normal (RN) Lens colour Order number Art. no. PS Weight kg V amber FD40IS/X/A/RN red FD40IS/X/R/RN green FD40IS/X/G/RN opal FD40IS/X/O/RN blue FD40IS/X/B/RN clear FD40IS/X/C/RN V amber SD40IS/X/A/RN red SD40IS/X/R/RN green SD40IS/X/G/RN opal SD40IS/X/O/RN blue SD40IS/X/B/RN clear SD40IS/X/C/RN Multiple module units are available. Contact your local sales office for details. example module combinations base colour 14004E E E E00 Single device Double device Triple device Quadruple device red normal (RN) 555

41 Instrinsically Safe LED Visual Flashing or Status Signal Series FD40IS, SD40IS & Technical Data Explosion protection Europe (ATEX) Gas and dust Certifications and certificates Certificates Electrical data Rated operational voltage Current consumption Certified input parameters Baseefa05ATEX0075 E II 1G Ex ia IIC T4 Ga E II 1D Ex ia IIIC T190 C Da ATEX, India (PESO) V Power supply Certified barrier / Current consumption isolator parameters 24 V DC 28 V / 300 Ω 22 ma 18 V DC *) 28 V / 300 Ω 14 ma *) Light output reduced U i = 30 V I i = 200 ma P i = 0.7 W C i = 0 L i = 0 Line monitoring yes Luminous characteristics Light source 8 array LED Flash rate 1/s (FD40IS only) Lens colour amber, red, green, opal, blue, clear Ambient conditions Operating C temperature range Storage temperature C Max. relative humidity 90 % at 40 C Mechanical data Cable entries 1 x M20 Material Enclosure ABS, flame retardant Lens polycarbonate, flame retardant Assembly parts stainless steel fixings Labels polyester foil, adhesive Degree of protection IP65 acc. to IEC Mounting / Installation Mounting All units are supplied separately from the base for ease of installation. The base should be mounted to a reasonably flat surface or bulkhead. A gasket is supplied, should the surface be uneven, or if the unit is to be used in wet conditions. The installation is completed by fitting the beacon onto the base by means of the supplied screws. Connection Each beacon should be wired independently. 2.5 mm 2 terminals 556

42 & Instrinsically Safe LED Visual Flashing or Status Signal Series FD40IS, SD40IS Accessories and Spare Parts Designation Figure Description Order number Art. no. PS WebCode Safety barrier single channel 9001/ A dual channel 9002/ A 02326E00 Galvanic isolator single channel 9176/ s A dual channel 9176/ s A Cabel gland 12530E /8-M pieces mm 2 (delivery lot *) ) 8161/8-M A 13027E00 *) Purchase order quantity in [pieces], the delivery quantity is automatically rounded to the delivery lot. Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 60,40 [2,38] 30,20 81,50 [3,21] 91,50 [3,60] 91,50 [3,60] A 1 x M20 A 1 x M20 5 [0,20] A ø 50,80 [ø 2,0 0] 1 x M20 [1,19] 45 A = knockout hole B 4 x M5 30,20 [1,19] 60,40 [2,38] C 4 x M E00 B = drill hole C = knockout hole A 2 x M E 557

43 LED Obstruction Light Low Intensity Series TEF 2430 > Complies with: ICAO annex 14 vol. 1 CH. 6, low intensity type B > Integrated terminal box > Low maintenance > Rugged construction > Low power consumption > Resistant to vibrations > Very long operating life Series TEF E00 WebCode T2430B ATEX / IECEx Zone For use in x x Selection Table Version Light intensity Voltage Order number Art. no. PS Luminaire Red LED 32 cd V AC TEF Omni-directional V AC TEF V AC / DC TEF Technical Data Explosion protection Global (IECEx) Gas IECEx DNV X Ex d e op is IIB T5 Gb Europe (ATEX) Gas NEMKO 03 ATEX 064 E II 2 G Ex d e op is IIB T5 Gb Certifications and certificates Certificates IECEx, ATEX, Canada (A), USA Rated voltage 220 / 254 V AC 50 / 60 Hz 110 / 120 V AC 50 / 60 Hz 24 V AC / DC Power consumption max W Service life min. 50,000 working hours Light intensity > 32 cd. according to ICAO annex 14 vol. I Ch. 6 low intensity type B Luminous intensity distribution Ambient temperature C Cable glands 4 x M25 cable gland delivered with: 2 x M25 stopping plugs 2 x M25 cable glands E00 558

44 LED Obstruction Light Low Intensity Series TEF 2430 Accessories and Spare Parts Designation Description Order number Art. no. PS Globe globe with guard, LED s and LED driver TEF Mounting plate complete with transformer V AC TEF O-Ring for globe / guard ring TEF Cable gland cable gland, M25 TEF Stopping plug drain plug EEx e M25 TEF stopping plug EEx e, M25 TEF Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 226 [8,90] 175 [6,89] 304 [11,97] 08471E00 559

45 Signal Beacon Series TEF 2430 > Rugged and low profile > Easy to install and maintain > Degree of protection IP66 / IP67 > Long lamp life due to compact fluorescent tube > Wide range of coloured globes > Short ignition time at low temperatures > Resistant to vibration Series TEF E00 WebCode T2430C ATEX / IECEx Zone For use in x x Selection Table Version Voltage Lamps Colour Order number Art. no. PS Luminaire 230 V 2 x 7 W clear TEF green TEF red TEF yellow TEF V 1 x 13 W clear TEF green TEF red TEF yellow TEF V DC 1 x 10 W clear TEF Technical Data Explosion protection Global (IECEx) Gas IECEx DNV X Ex d e IIB T5 Gb Europe (ATEX) Gas NEMKO 03 ATEX 064 E II 2 G Ex d e IIB T5 Gb Certifications and certificates Certificates IECEx, ATEX, Canada (A), USA Light intensity > 10 candela red > 70 candela yellow > 80 candela white Ambient temperature C Degree of protection IP66 / IP67 Material cast copper alloy globe: polycarbonate lexan Cable glands 4 x M25 stopping gland 1 x M25 cable glands green TEF red TEF yellow TEF blue TEF amber TEF

46 Signal Beacon Series TEF 2430 Accessories and Spare Parts Designation Description Order number Art. no. PS Fluorescent tube 7 W TEF PLC 13 W 120 V TEF PLC 10 W / 827 G24, 24 V TEF Light fitting insert 230 V, complete TEF V AC, complete TEF V DC, complete TEF Lamp holder G23 TEF Globe clear TEF green TEF red TEF yellow TEF blue TEF yellow amber TEF O-Ring for globe / guard ring TEF Cable gland cable gland, M25 TEF Reactor fluor. tube 2 x 7 W, 230 V / 240 V 50 / 60 Hz TEF fluor. tube 2 x 7 W, 230 V / 240 V 50 / 60 Hz TEF Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 226 [8,90] 175 [6,89] 304 [11,97] 08471E00 561

47 Signal Beacon - Zone 2 Series TEF 2440 Series TEF 2440 WebCode T2440A 06432E00 > Application deck lighting signal lighting obstacle marking > Rugged construction > Easy to install and maintain > Degree of protection IP66 / IP67 > Long lamp life due to compact fluorescent tube > Versatility offering variable mounting positions > Optional internal lamp reflector > Wide range of coloured globes available > Short ignition time at low temperatures > Resistant to vibrations ATEX Zone For use in x Selection Table Version Lamps Rated voltage Colour of glass Order number Art. no. PS Weight kg Signal light Series TEF 2440 Technical Data Explosion protection Europe (ATEX) Gas 1 x 13 W 230 V AC clear TEF green TEF red TEF amber TEF blue TEF yellow TEF V AC clear TEF red TEF amber TEF blue TEF NEMKO 03ATEX3336 E II 3 G EEx na II T3/T4 Certifications and certificates Certificates ATEX Rated voltage 230 V AC 50/60 Hz 120 V AC 60 Hz Power consumption 18 W Lamp version PL-C compact fluorescent tube, max. 13 W Lamp holder G 24 D / 1 Light intensity > 10 cd red > 80 cd yellow > 90 cd white Ambient temperature C Degree of protection IP66 / IP67 Material Enclosure acid proof stainless steel, powder coated (RAL 9002) Globe polycarbonate Colour of glass white, yellow, red, blue, green and amber Cable entries 1 x cable gland M25 1 x stopping plug M25 562

48 Signal Beacon - Zone 2 Series TEF 2440 Accessories and Spare Parts Designation Description Order number Art. no. PS Weight kg Globe clear, spare part kit TEF green, spare part kit TEF red, spare part kit TEF yellow amber, spare part kit TEF blue, spare part kit TEF Ballast ballast and lamp holder, spare part kit TEF Fluorescent lamps PLC 13 W / V TEF PLC 10 W / V TEF PLC 13 W 120 V TEF Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 163,30 [6,43] 146,30 [5,76] 120 [4,72] 4 x ø 6,50 [ 4 x ø 0,26] 100 [3,94] 140 [5,51] 78,50 [3,09] 205 [8,07] 06430E00 563

49 Obstruction Light LED Series TEF 2460 Series TEF E00 > Complies with: ICAO Annex 14 Vol. 1 Ch. 6, Low intensity type A or B > Integrated terminal box with drain plug/breather > Low maintenance > Rugged construction > Encapsulated electronics. No risk of water intrusion to LED s and electronics > Instant light > Resistant to vibrations WebCode T2460A ATEX / IECEx Zone For use in x x Selection Table Version Lamps Light intensity Voltage Order number Art. no. PS Obstruction Light LED red LED 10 cd 24 V DC ±30 % TEF Series TEF V AC TEF cd 24 V DC ±30 % TEF V AC TEF red + IR 10 cd 24 V DC ±30 % TEF version is NVG compatible 32 cd 24 V DC ±30 % TEF Technical Data Explosion protection Global (IECEx) Gas IECEx Pre Ex e mb op is IIC T5 Gb Europe (ATEX) Gas PRESAFE 14 ATEX 4571 Certifications and certificates Certificates Electrical data Rated voltage IECEx, ATEX Power consumption Service life Luminous characteristics Light intensity Ambient conditions Ambient temperature C Operating temperature C Mechanical data Degree of protection IP66 Cable glands 2 x M25 x V AC 24 V DC ±30 % W (depending on the version) Min. 50,000 working hours > 32 cd and 10 cd versions, according ICAO Annex 14 Vol. I, low intensity type A and B Accessories and Spare Parts Designation Description Order number Art. no. PS Dome with gasket TEF Screw M5x16 red. shank TEF Drain plug drain plug EEx e M25 TEF Stopping plugs M25 TEF Cable glands M25 d11-15/15-20 mm TEF Terminal insert TEF

50 Perimeter Light LED Series TEF 2460 > Integrated terminal box with drain plug/breather > Low maintenance > Rugged construction > Encapsulated electronics. No risk of water intrusion to LED s and electronics > Instant light > Resistant to vibrations Series TEF E00 WebCode T2460B ATEX / IECEx Zone For use in x x Selection Table Version Lamps Light intensity Voltage Order number Art. no. PS Perimeter light LED Series TEF 2460 green LED 30 cd V AC TEF V DC ±30 % TEF green/red LED 30 cd 24 V DC ±30 % TEF Technical Data Explosion protection Global (IECEx) Gas IECEx Pre Ex e mb op is IIC T5 Gb Europe (ATEX) Gas PRESAFE 14 ATEX 4571 Certifications and certificates Certificates IECEx, ATEX Electrical data Rated voltage V AC 24 V DC ±30 % Power consumption 4 W Service life Min. 50,000 working hours Luminous characteristics Light intensity > 30 cd > 15 cd > 3 cd < 60 cd in all directions (according ICAO Annex 14 Vol. II and CAP 437) Ambient conditions Ambient temperature C Operating temperature C Mechanical data Degree of protection IP66 Cable glands 2 x M25 x 1.5 Accessories and Spare Parts Designation Description Order number Art. no. PS Glas dome TEF Terminal insert TEF Cable glands M25 d11-15/15-20 mm TEF Stopping plugs M25 TEF Drain plug drain plug EEx e M25 TEF Screw M5x16 red. shank TEF

51 Navigation Light Series TEF 2850 Series TEF E00 > Integrated terminal box > Hinged on top - enabling quick replacement of light source > All round lanterns are delivered with mounting bracket for 2 pipe > Designed for use in arctic and tropical waters > Resistant to vibrations > Lens of through-coloured glass - no de-colouration throughout the lifetime of the lantern WebCode T2850A ATEX Zone For use in x Selection Table Version Version of light fitting Colours Light aperture Order number Art. no. PS Weight Navigation light Series TEF 2850 Technical Data Explosion protection Europe (ATEX) Gas kg Masthead white 225 TEF Starboard green TEF Port red TEF Stern white 135 TEF Stern towing yellow 135 TEF Suez red red 135 TEF Allround white white 360 TEF Allround green green 360 TEF Allround red red 360 TEF NEMKO Ex 99Y060 E nr II T5 (Only on request) Certifications and certificates Certificates ATEX Ship approval DNV Rated voltage 24, 120, 230 V AC / DC Lamp version 55 W for vessels m 85 W for vessels >50 m Degree of protection IP56 Lamp holder B22 / E27 / P28S Power consumption W, dependant on light source Operating temperature range C Material Enclosure Aluminium Lens glass coloured glass 566

52 Navigation Light Series TEF 2850 Accessories and Spare Parts Designation Description Order number Art. no. PS Lens clear TEF green TEF red TEF yellow TEF grey TEF Lamp holder B22 TEF E27 TEF Light source 65cd, B22, 230 V TEF cd, B22, 120 V TEF cd, B22, 230 V TEF cd, B22, 120 V TEF cd, B22, 24 V TEF W, P28S, 24 V TEF Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Pg E Pg E00 Sector lantern TEF 2850 All round lantern TEF

53 Windsock Illuminated Series TEF 9967 Series TEF 9967 WebCode T9967A 06366E00 > Wind indication on: Helicopter landing areas Airports Bridges Highways > Rugged and solid construction > 4 certified luminaires mounted in SS316L reflector with junction box > Easy to install and maintain > 1 or 2 obstruction lights on top > To be mounted on top of 2 tube > Cable for power supply through 2 tube > Resistant to vibrations > Bearing for rotating the wind cone encapsulated in solid brass housing ATEX Zone For use in x x Selection Table Version Luminaires Voltage Size Use in Order number Art. no. PS Windsock without d = 0.6 m TEF Series TEF 9967 L = 2.4 m d = 1.0 m L = 3.6 m TEF with Series TEF 2430 with Series TEF V d = 0.6 m L = 2.4 m 230 V d = 1.0 m L = 3.6 m 120 V d = 0.6 m L = 2.4 m 120 V d = 0.6 m L = 2.4 m 230 V d = 1.0 m L = 3.6 m Zone 1 TEF Zone 1 TEF Zone 2 TEF safe area TEF Zone 2 TEF Technical Data Rated voltage 230 / 240 V AC, 50 / 60 Hz 110 / 120 V AC, 60 Hz Power consumption <100 W Degree of protection IP66 / IP67 (acc. to IEC 529) Material Cover in acid proof steel (SS316L). Bearing in solid brass. The arrangement can be equipped with different models of luminaires from Tranberg, dependant on the area of use. Weight with luminaire Series TEF 2440, Zone 2 / safe area: 57 kg with luminaire Series TEF 2430, Zone 1: 78 kg 568

54 Windsock Illuminated Series TEF 9967 Accessories and Spare Parts Designation Description Order number Art. no. PS Windsock d = 0.5 m; L = 2.0 m; colour: orange TEF d = 0.6 m; L = 2.4 m; colour: orange TEF d = 1.0 m; L = 3.6 m; colour: orange TEF Dimensional Drawings (All Dimensions in mm) - Subject to Alterations (2000) (1000) (3600) 06362E00 569

55 Windsock with Internal Illumination Series TEF 9968 Series TEF 9968 WebCode T9968A 17797E00 > Rugged and solid construction > Easy to install and maintain, maintenance free lights > The windsock is internally lit with red light, causing minimal glare and minimal reduction in pilot s ability to see in the dark > Delievered with 10 m flying lead armored cable (other lenghts on request) > Red + IR (NVG compatible) obstruction light available > Resistant to vibrations > Bearing for the rotation wind vane, is encapsulated in solid brass housing > EN/DIN mounting flange for 60.3 mm pipe > Delivered with one spare windsock kit ATEX / IECEx Zone For use in x x Selection Table Version Light intensity Rated voltage Size Colour Order number Art. no. Windsock Series TEF Cd 24 V DC d = 0.3 m L = 1.3 m orange TEF on request d = 0.6 m L = 2.4 m orange TEF on request d = 1.0 m L = 3.6 m orange TEF on request 230 V AC d = 0.3 m L = 1.3 m orange TEF on request d = 0.6 m L = 2.4 m orange TEF on request d = 1.0 m L = 3.6 m orange TEF on request 32 Cd IR 24 V DC d = 0.3 m L = 1.3 m orange TEF on request d = 0.6 m L = 2.4 m orange TEF on request d = 1.0 m L = 3.6 m orange TEF on request 230 V AC d = 0.3 m L = 1.3 m orange TEF on request d = 0.6 m L = 2.4 m orange TEF on request d = 1.0 m L = 3.6 m orange TEF on request Note The windsocks is supplied with Obstruction Lights Series TEF Special option: colour white/red on request Technical Data Explosion protection Global (IECEx) Gas IECEx PRE Ex e mb op is IIC T5 Gb Europe (ATEX) Gas Presafe 14ATEX4571 E II 2 G Ex e mb op is IIC T5 Gb Certifications and certificates Certificates IECEx, ATEX, IMO, CAA CAP 437, ICAO Annex

56 Windsock with Internal Illumination Series TEF 9968 Technical Data Electrical data Rated voltage 24 V DC +/-30 % V AC Power consumption 15 W Mechanical data Degree of protection IP66 / IP67 (acc. to IEC 60529) Material brass and stainless steel (EN ), polycarbonate dome on lamps Weight approx. 50 kg Ambient temperature Luminaires with Series TEF 2460 Obstruction Light Accessories and Spare Parts Designation Description Order number Art. no. PS Windsock d = 0.3 m; L = 1.3 m; colour: orange TEF d = 0.6 m; L = 2.4 m; colour: orange TEF d = 0.6 m; L = 2.4 m; colour: red/white TEF d = 1.0 m; L = 3.6 m; colour: orange TEF Full bearing for windsock arrangement TEF Flange for mounting on 60.3 mm pipe, max Ø = 61 mm, TEF on request complete with bolts and nuts for welding to 60.3 mm pipe, EN , TEF on request complete with bolts and nuts Power supply Please contact Tranberg AS or R. STAHL for a suitable power supply on request on request Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 165 [ 6,50] Ø Ø 125 [4,92] 125 [4,92] 4 x Ø18 [ Ø 0,71] opr.: Ex: C C L Dimensions in mm L d1 d2 TEF TEF TEF [42,72] d1 d E00 571

57 Flameproof Manual Call Points Series MCP & > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied with reset key and lift flap > Optional extras include stainless steel lift flap, duty and tag labels Series MCP 13915E00 WebCode MCPA ATEX / IECEx Zone For use in x x x x Selection Table Version Action type Enclosure colour Order number Art. no. PS Weight kg MCP Manual Call Points, Atex certification, standard devices Type Code Break glass red normal (R) MCP/BG/SP/Ex/A+B+C+D/EU/R Push button red normal (R) MCP/PB/SP/Ex/A+B+C+D/EU/R Variations MCP / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ Version break glass BG push button PB Contacts 1 change over SP 2 change over DP Explosion protection Cable entries standard standard 4 x M20 with 3 x Ex d stopping plugs and 1 x dust cap glands to be ordered separately Certification ATEX EU IECEx IN GOST R RU Colour red R blue B green G yellow Y black BK yellow / black stripe YB Accessories Labels (please specify wording) lift flap (break glass version only) end of line resistor inline resistor end of line and Inline resistor LED signal duty label tag label Ex A+B+C+D LF EOL IL ILEOL LED D T Additional approvals L 572

58 & Flameproof Manual Call Points Series MCP Versions Break Glass (BG) 14716E00 Push Button (PB) 04035E00 Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BAS X IEC : 2011 / IEC : / IEC : 2008 Ex d IIC T6 Ta C Gb Ex tb IIIC T85 C Ta C Db IP66 Europe (ATEX) Gas and dust Certifications and certificates Electrical data Rated operational voltage Switching capacity Baseefa 08ATEX0269X EN : 2009 / EN : 2007 / EN : 2009 E II 2 G Ex d IIC T6 Ta C Gb E II 2 D Ex tb IIIC T85 C Ta C Db IP66 IECEx, ATEX, Brazil (INMETRO), India (PESO) V DC, V AC DC V 3 A V 1 A AC V 5 A Contact element standard: 1 change-over contact optional: 2 change-over contacts Switch NO or NC System test Test key provided Ambient conditions Operating temperature range C Mechanical data Material Enclosure material glass fibre reinforced polyester (GRP) Surface finish two pack, acrylic polyurethane, various colour options Degree of protection IP66 acc. to IEC Cable entries 4 cable entries, supplied with (3x) Ex d stopping plugs and (1x) dust cap Position of cable entries Break glass call point Connection Terminals 7 way terminal block., 4 mm 2 Earth connection provided as standard 13952E E E00 Break glass call point with lift flap Push button call point 573

Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60 > Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable

More information

Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60 > Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Pendant Light Fittings Series 6050

Pendant Light Fittings Series 6050 > Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

EXLUX ECOLUX 6480 Series

EXLUX ECOLUX 6480 Series EXLUX ECOLUX 6480 Series L I G H T I N G 6000 6008 6400 6408 6600 6608 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

EXLUX ECOLUX C-LUX 6480 Series

EXLUX ECOLUX C-LUX 6480 Series EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

Horn loudspeaker, Ex proof, short/long flare

Horn loudspeaker, Ex proof, short/long flare Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure

More information

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder EXEL - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22 Reinforced polyester resin body G13 bi-pin lamp holder Internal emergency batteries

More information

Optical Signal Devices. Free-standing Beacons

Optical Signal Devices. Free-standing Beacons Free-standing Beacons Overview Free-standing Permanent Beacons Flashing Beacons 200/203 201/204 (LED) 209 209 (LED) 210/213 211/214 (LED) 219 219 (LED) 202 Flashing 205 Flashing 209 Flashing Beacon 212

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations LED Class I, Division 2, Groups A, B, C, & D Class II, Divisions 1 & 2, Groups E, F & G Class III UL 1598A Marine Outside Type UL 1598 Wet Locations UL 844 Hazardous Locations UL 8750 LED Safety Tested

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

XML LED X M L L E D. Explosionproof Linear LED Lighting

XML LED X M L L E D. Explosionproof Linear LED Lighting LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924

More information

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS 3-6VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure

More information

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof 2 x 58 W Compliance Data: ATEX IECEx: ATEX IECEx CE Ex d IIB Ex d IIC

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

Model JDF Field Indicator

Model JDF Field Indicator Data Sheet DS/JDF-EN Rev. F Model JDF Field Indicator Engineered solutions for all applications Measurement made easy Digital LCD provides reliable and clear indications Flexible configuration facilities

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-12360 This is to certify that the Cable Gland with type designation(s) ADE & RE; AD; FF; MM; SP; ET; LN. Manufactured by COOPER CAPRI SAS

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem

More information

I Ex-protected connectors exlink I

I Ex-protected connectors exlink I Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell

More information

PROPORTIONAL VALVES Sentronic plus

PROPORTIONAL VALVES Sentronic plus 04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital

More information

Champ-Pak Wall Pack Luminares

Champ-Pak Wall Pack Luminares Restricted Breathing Cl. I, Div. 2 & Zone 2 ( S826) ( S826TB) Cl. III & Simultaneous Presence Marine & Wet Locations The first low-profile wall pack designed specifically for hazardous areas. The Eaton

More information

PRE Series 16 Amp Plugs and Sockets Increased Safety

PRE Series 16 Amp Plugs and Sockets Increased Safety s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 16 Amp s and Sockets - IK09/10 Applications s and receptacles are used with portable or stationery electrical equipment

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

Installation instructions Cable transit device Roxtec RS ES Ex

Installation instructions Cable transit device Roxtec RS ES Ex General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent Areamaster LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2 AEx na IIC, Ex na IIC Type 3R, 4, 4X /67 NEC: Marine Outside Type (Salt Water) Wet Locations Applications

More information

Pressure transmitter For applications in hazardous areas Model IS-3

Pressure transmitter For applications in hazardous areas Model IS-3 Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine

More information

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance Technic Cross-Flow Fans T R A N S F O R M E R C O O L I N G S O L U T I O N S Transformer Cross-Flow Fans General Information provides optimal solutions for air forced cooling of transformers. High performance

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

Installation instructions Ex frames

Installation instructions Ex frames General information Installation and maintenance: For European member countries of GENELEC shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,

More information

LIGHTING SOLUTIONS. The bright side of the ship

LIGHTING SOLUTIONS. The bright side of the ship LIGHTING SOLUTIONS The bright side of the ship Philosophy Three things you should know about us 1Established by experienced specialists in 1995, Lightpartner has developed into the leading provider of

More information

TECHNICAL DATA. Type. TMC2X Design Specification. Category B ATEX Certificate. Code of Protection. IECEx SIR X Code of Protection

TECHNICAL DATA. Type. TMC2X Design Specification. Category B ATEX Certificate. Code of Protection. IECEx SIR X Code of Protection CABLE CONNECTION SPECIALISTS E F D G B A REMOVABLE ARMOR STOP TMC2X CABLE CONNECTOR TECHNICAL DATA TMC2X Wet & Hazardous Location Cable Connector Type TMC2X Design Specification EN 50262, BS 6121:Part

More information

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

EX-PROTECTED PORTABLE POWER SUPPLY UNITS EX-PROTECTED PORTABLE POWER SUPPLY UNTS 125 A for Zone 1 Special requirements apply for power distributions for the use and operation of portable equipment in hazardous areas in Zones 1, 2, 21 and 22.

More information

General Specifications

General Specifications General Specifications FVX110 Fieldbus Segment Indicator The FVX110 is a field indicator that allows you to switch and display up to 16 indicated values for FOUNDATION TM fieldbus devices. Turn the scroll

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

Illustrated Feature. Options

Illustrated Feature. Options Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

Installation instructions Roxtec RS ES Ex

Installation instructions Roxtec RS ES Ex General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix Contents 1. Introduction 2. Selecting a model 2.1 Mounting 2.1.1 Field mounting 2.1.2

More information

Panel Mount Signaling Alarms

Panel Mount Signaling Alarms Panel Mount Signaling Alarms Bulletin 855P Panel Mount Signaling Alarms Build a Catalog Number Mounts in standard 22.5 mm hole Watertight panel alarms in three different sizes Sound output 72 105 db @

More information

Product Data Sheet 4656 ZW

Product Data Sheet 4656 ZW The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

VDI structed cabling system and warning devices. Flashing and rotating lights. Industrial bells (P. 324) (P. 325) VDI structured cabling system

VDI structed cabling system and warning devices. Flashing and rotating lights. Industrial bells (P. 324) (P. 325) VDI structured cabling system VDI structured cabling system P. 322 LCS patch panels and units Bells, sirens, buzzers and warning lights P. 324 Electromechanical sirens P. 325 Flashing and rotating lights VDI structed cabling system

More information

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure

More information

Product Data Sheet 8506 VW-691

Product Data Sheet 8506 VW-691 The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

ENCODERS FOR OIL & GAS

ENCODERS FOR OIL & GAS ENCODERS FOR OIL & GAS Explosive atmospheres demand extraordinary encoder solutions Even in the toughest environments Leine & Linde encoders have to be reliable and work perfectly. With a development process

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA

More information

ExCam XPT Q6055. User Manual

ExCam XPT Q6055. User Manual ExCam XPT Q6055 User Manual Table of contents 1 Introduction... 4 2 Technical data... 5 2.1 Explosion protection... 5 2.2 Electrical parameters of the camera... 5 2.3 Connection cable Ex-d - Ex-e (ASKDP03-T)...

More information

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2 IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2 10. Cable entry systems and blanking elements 10.2 Selection of cable

More information

PMG. Vibration Energy Harvesters

PMG. Vibration Energy Harvesters FEATURES Designed to power high performance Wireless Sensor Nodes. High power output up to 27.5mW High reliability design, including hermetically-sealed stainless steel case. Intrinsically Safe for use

More information

STROBE SIGNAL LIGHT. Catalog Number Logic ES X (CEN)* Series Constant. Signal Type X Strobe

STROBE SIGNAL LIGHT. Catalog Number Logic ES X (CEN)* Series Constant. Signal Type X Strobe KILLARK ESX SERIES STROBE SIGNAL LIGHT Class I, Div. 1 & 2, Groups C,D Class I, Zones 1 & 2, Groups IIB, IIA Class ll, Div. 1 & 2 Groups E,F,G Class lll, Div. 1 & 2 Suitable for wet locations UL Marine

More information

NEW NEW NEW. Page 137. Page 138. Page 128. Page 136. Page 134. Page 134 Page 139

NEW NEW NEW. Page 137. Page 138. Page 128. Page 136. Page 134. Page 134 Page 139 Page 137 Page 138 Page 128 Page 134 Page 136 Page 134 Page 139 Summary Optical-Audible Signal Devices Page 135 Page 125 Installation LED/Buzzer Combination 150 420 Page 137 Page 124 Free-standing version

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

Safety dialogue solutions

Safety dialogue solutions Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

Linear flow control with actuator IFC

Linear flow control with actuator IFC Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20

More information

Loudspeakers. < Makes the world sound >

Loudspeakers. < Makes the world sound > Loudspeakers < Makes the world sound > April 2005 < Makes the world sound > The original DNH design DNH designs and manufactures one of the world's largest range of loudspeakers. New Products Since the

More information

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS SERIES BNC 50, COAXIAL MINIATURE CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER BNC is still one of the most popular connector series, featuring a two stud bayonet coupling mechanism, which is particularly

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.

USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -. d.o.o. tel. 049 900, fax 049 46 450 email: tepex@tepex.hr www.tepex.hr USER MANUAL FOR EPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE. Doc. No: TEPEx.RS.058 Ver : 0 Date: 11.014. SADRŽAJ 1. Manufacturer

More information

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance

More information

Datasheet EC-750 Ex DOME Camera

Datasheet EC-750 Ex DOME Camera Product: EC-750 Ex DOME Camera Description and highlights Explosion proof color TV camera with swivelling head and zoom Chemical, shock and vibration resistant Water- and dustproof IP68 Compact and light

More information

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups

More information

Product Data Sheet 4656 EZ

Product Data Sheet 4656 EZ The engineer's choice 4656 EZ INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

82540/ /2-way diaphragm valves

82540/ /2-way diaphragm valves > > ort size: DN 8... 50, 1/4... 2 (ISO G/NT) > > Valve operates without differential pressure > > High flow rate > > For robust industry solutions > > Damped operation > > Suitable for vacuum > > Solenoid

More information

Level Measurement Point level measurement RF Capacitance switches

Level Measurement Point level measurement RF Capacitance switches Siemens AG 2018 Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces,

More information

Linear flow controls VFC Linear flow controls with actuator IFC

Linear flow controls VFC Linear flow controls with actuator IFC Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or

More information

WLB SERIES HID Lighting for Hose Down Applications

WLB SERIES HID Lighting for Hose Down Applications WLB SERIES W LB HID Lighting for Hose Down Applications Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations NEMA 4X NSF Certified Food Equipment CUL Heavy Hose

More information

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination Engineering Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division factory-sealed LED luminaire for general illumination High-performance, high-brightness Hazard Gard EVLL LED Luminaire

More information

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0

More information

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced) Siemens AG 07 Y Article No. Pressure transmitters for absolute pressure from differential pressure series, SITRANS P DS III with HART 7 M 4-7 7 7 7 7-7 7 7 7 Click on the Article No. for the online configuration

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

Eddy Current Probe System

Eddy Current Probe System CMSS 785 Eddy Current Probe System API-670 Proximity transducer system, 5 mm and 8 mm Eddy Current Probe System The CMSS 785 system is an eddy current type non-contact displacement/ vibration system, used

More information

Safety Light Curtains GuardShield

Safety Light Curtains GuardShield Description The Allen-Bradley Guardmaster safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. safety light curtains are general purpose presence

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information