Operating Instructions

Size: px
Start display at page:

Download "Operating Instructions"

Transcription

1 Drive Technology \ Drive Automation \ System Integration \ s Operating Instructions Stationary Energy Supply MOVITRANS Installation Material TCS, TVS, TLS, TIS Edition 04/ / EN

2 SEW-EURODRIVE Driving the world

3 Contents Contents 1 General Information How to use this documentation Structure of the safety notes Rights to claim under limited warranty Exclusion of liability Copyright Product names and trademarks Safety Notes Preliminary information General information Target group Designated use Transport Storage Installation Functional safety technology Electrical connection Safe disconnection Startup/operation Inspection/maintenance Unit Design Type designation Nameplate Scope of delivery TCS compensation box TVS connection distributor TLS line cable/supply cable TIS10...-V..-0 installation plate TIS...-X..-0 retaining plate TIS...-H..-0 holding fixture TIS...P..-0 rigid profile section TIS...-F..-0 flexible profile section TIS...-A..-0 cable bushing Installation General information Prefabrication of the TLS line cable Prefabrication of the TLS supply cable Connecting the TLS line cable to the TCS compensation box Connecting the TLS line cable to the TVS connection distributor Connecting the TLS supply cable to the TVS connection distributor Eartch connection of the compensation box / connection distributor Earth connection of compensation box / connection distributor Installing the TIS10A equipment Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 3

4 Contents Disposal Technical Data Applicable standards and directives Certifications TLS line cable/supply cable Dimension Sheets TCS10A / TCS10B compensation box TVS10A / TVS10B connection distributor TIS...-V..-0 installation plate TIS...-X..-0 retaining plate TIS...-H..-0 holding fixture TIS...-P..-0 rigid profile section TIS...-F..-0 flexible profile section TIS...-A..-0 cable bushing Shielding plate Address List Index Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

5 General Information How to use this documentation 1 MOVITRANS Æ Installation Material TCS, TVS, TLS, TIS 1 General Information 1.1 How to use this documentation The documentation is an integral part of the product and contains important information on operation and service. The documentation is written for all employees who assemble, install, startup, and service this product. The documentation must be accessible and legible. Make sure that persons responsible for the system and its operation, as well as persons who work independently on the unit, have read through the documentation carefully and understood it. If you are unclear about any of the information in this documentation, or if you require further information, contact SEW-EURODRIVE. 1.2 Structure of the safety notes Meaning of the signal words The following table shows the grading and meaning of the signal words for safety notes, notes on potential risks of damage to property, and other notes. Signal word Meaning Consequences if disregarded DANGER Imminent danger Severe or fatal injuries WARNING Possible dangerous situation Severe or fatal injuries CAUTION Possible dangerous situation Minor injuries NOTICE Possible damage to property Damage to the drive system or its environment INFORMATION Useful information or tip: Simplifies the handling of the drive system Structure of the section-related safety notes Section safety notes do not apply to a specific action, but to several actions pertaining to one subject. The used symbols indicate either a general or a specific hazard. This is the formal structure of a section safety note: SIGNAL WORD Type and source of danger. Possible consequence(s) if disregarded. Measure(s) to prevent the danger Structure of the embedded safety notes Embedded safety notes are directly integrated in the instructions just before the description of the dangerous action. This is the formal structure of an embedded safety note: SIGNAL WORD Nature and source of hazard. Possible consequence(s) if disregarded. Measure(s) to prevent the danger. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 5

6 1 General Information Rights to claim under limited warranty 1.3 Rights to claim under limited warranty A requirement of fault-free operation and fulfillment of any rights to claim under limited warranty is that you adhere to the information in the documentation. Read the documentation before you start working with the unit! 1.4 Exclusion of liability You must comply with the information contained in this documentation to ensure safe operation of MOVITRANS and to achieve the specified product characteristics and performance features. SEW-EURODRIVE assumes no liability for injury to persons or damage to equipment or property resulting from non-observance of these operating instructions. In such cases, any liability for defects is excluded. 1.5 Copyright 2011 SEW-EURODRIVE. All rights reserved. Unauthorized duplication, modification, distribution or any other use of the whole or any part of this documentation is strictly prohibited. 1.6 Product names and trademarks All brands and product names in this documentation are trademarks or registered trademarks of their respective titleholders. 6 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

7 Safety Notes Preliminary information 2 2 Safety Notes 2.1 Preliminary information The following basic safety notes must be read carefully to prevent injury to persons and damage to property. The operator must ensure that the basic safety notes are read and observed. Make sure that persons responsible for the plant and its operation, as well as persons who work independently on the units, have read through the documentation carefully and understood it. Consult SEW-EURODRIVE if you have any questions or if you require further information. The following safety notes are primarily concerned with the use of MOVITRANS units. If you use other SEW components, also refer to the safety notes for the respective components in the corresponding documentation. Please also observe the supplementary safety notes in the individual sections of this documentation. 2.2 General information Removing covers without authorization, improper use as well as incorrect installation or operation may result in severe injuries to persons or damage to property. 2.3 Target group Any mechanical work may only be performed by adequately qualified personnel. Qualified personnel in this context are persons who are familiar with the setup, mechanical installation, troubleshooting and maintenance for the units. Further, they are qualified as follows: Training in mechanical engineering, e.g. as a mechanic or mechatronics technician (final examinations must have been passed). Knowledge of this documentation Any electronic work may only be performed by adequately qualified electricians. Qualified electricians in this context are persons who are familiar with the electronic installation, startup, troubleshooting and maintenance for the units. Further, they are qualified as follows: Training in electrical engineering, e.g. as an electrician or mechatronics technician (final examinations must have been passed). Knowledge of this documentation All work in further areas of transportation, storage, operation and waste disposal may be carried out only by persons who are trained appropriately. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 7

8 2 Safety Notes Designated use 2.4 Designated use Note the designated use of the following MOVITRANS units: MOVITRANS units in general MOVITRANS units are intended for use in industrial and commercial installations for the operation of contactless power transmission systems. TPS stationary converter and TAS transformer modules TPS stationary converters and TAS transformer modules are designed to be installed in control cabinets. Only connect MOVITRANS devices that are designed and suitable for connection to TPS stationary converters and the TAS transformer modules, such as TLS line cables, TVS connection distributors and TCS compensation boxes. TLS line cables The TLS lines cables are laid along the transmission line. The TLS line cables are suitable for the connection to the TAS transformer module on the output side. TCS compensation boxes In longer transmission lines, the TCS compensation boxes are connected in series to the TLS line cables. TVS connection distributor The TVS connection distributors are used as connection points for the TLS line cable in the field. TIS installation material The installation components TIS may only be used with flat pick-ups THM..E. The installation components TIS may only be used with U-shaped pick-ups THM..C. Observe all information on the technical data and the permitted conditions where the units are operated. Do not start up the unit (operate in the designated fashion) until you have established that the machine complies with the EMC Directive 2004/108/EC and that the end product categorically conforms to Machinery Directive 2006/42/EC (with reference to EN 60204). The rules and regulations of the German employers' liability insurance association ["Berufsgenossenschaft" - BG], in particular BG rules B11 concerning electromagnetic fields, must be observed during installation, startup and operation of systems with contactless energy transfer by induction for use in industrial workplaces. 8 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

9 Safety Notes Transport Transport Observe the following instructions when you receive a shipment: Inspect the shipment for any damage that may have occurred in transit as soon as you receive the delivery. Inform the shipping company immediately about any damage. Do not startup any units if they were damaged in transit. Observe the following notes for the transportation of MOVITRANS units: Make sure that the units are not subject to mechanical impact during transport. Use suitable, sufficiently rated handling equipment. Observe the notes on the climatic conditions in the "Technical Data" chapter. Remove transport fixtures prior to startup. 2.6 Storage Observe the following instructions when shutting down or storing MOVITRANS units: Make sure that the units are not subject to mechanical impact during storage. In case of long-term storage, connect the TPS stationary converter to the power supply for at least 5 minutes every 2 years. Observe the notes on storage temperature in the "Technical Data" chapter. 2.7 Installation Observe the following notes for installing the MOVITRANS units: Protect the MOVITRANS units from excessive strain. Ensure that components are not deformed and/or insulation spaces are maintained, particularly during transportation and handling. Electric components must not be mechanically damaged or destroyed. The following applications are prohibited unless the unit is explicitly designed for such use: Use in potentially explosive atmospheres. Use in areas exposed to harmful oils, acids, gases, vapors, dust, radiation, etc. Use in applications that are subject to mechanical vibration and shock loads in excess of the requirements in EN Functional safety technology MOVITRANS units may not execute any safety functions without master safety systems. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 9

10 2 Safety Notes Electrical connection 2.9 Electrical connection Observe the following notes for the electrical connection of MOVITRANS units: Do not connect or disconnect any cables, plug connectors or conductor rails while they are energized. Observe applicable national accident prevention guidelines when working on live parts of MOVITRANS units. Perform electrical installation according to the pertinent regulations (e.g. cable crosssections, fusing, protective conductor connection). For any additional information, refer to the applicable documentation. Preventive measures and protection devices must correspond to the regulations in force (e.g. EN or EN 50178). Required preventive measures: Ground the units Required protection device: Over-current protection devices for the supply system lead Take suitable steps to ensure that the preventive measures and protection devices described in the operating instructions for the individual MOVITRANS units have been implemented correctly Safe disconnection The TPS stationary converter meets all requirements for safe disconnection of power and electronics connections in accordance with EN All connected circuits must also maintain the requirements for safe disconnection. 10 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

11 Safety Notes Startup/operation Startup/operation Observe the following notes for starting up and operating the MOVITRANS units: Only qualified electricians with the relevant accident prevention training are allowed to perform installation, startup and service work on the unit. They must also comply with the regulations in force (e.g. EN 60204, VBG 4, DIN-VDE 0100/0113/0160). Never install damaged units and put them into operation. Do not deactivate monitoring and protection devices even for a test run. Take appropriate measures (for example, connect binary input DI00 "/CONTROL- LER INHIBIT" to DGND on the TPS stationary converter) to ensure that the system does not start up unintentionally when power is switched on. During operation, the MOVITRANS units can have live, bare and movable or rotating parts as well as hot surfaces, depending on their degree of protection. When the unit is switched on, dangerous voltages are present at the output terminals and at any connected cables, terminals and MOVITRANS units. Dangerous voltages can be present even when the TPS stationary converter supply is disabled and the system is at a standstill. The fact that the operation LED V1 and other display elements are no longer illuminated on the TPS stationary converter does not indicate that the device and connected MOVITRANS units have been disconnected from the power supply and do not carry any voltage. Safety functions within the unit may cause system standstill. Removing the cause of the problem or performing a reset can result in an automatic restart of the plant. If safety reasons prohibit this action, disconnect the TPS10A stationary converter from the power supply before correcting the fault. Before removing the protective cover, disconnect the units from the supply system. Dangerous voltages may still be present in the units and the connected MOVITRANS devices for up to 10 minutes after disconnection. With the protective cover removed, the MOVITRANS units have enclosure IP00. Dangerous voltages are present at all components. All units must be closed during operation. Please wear appropriate protective clothing during assembly, especially when soldering the TLS line cables. Take appropriate security measures to prevent burns by the soldering iron or by hot solder. Take appropriate measures to prevent hot solder from leaking Inspection/maintenance Only SEW-EURODRIVE is authorized to carry out repairs. Never open the unit. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 11

12 3 Unit Design Type designation 3 Unit Design 3.1 Type designation Type designation of the TCS compensation box The type designation of the TCS compensation box comprises following characteristic data: TCS E Design of the flange plate/connections: 1 = 4 M25, 4 M25 3 = 2 M32, 2 M32 Compensation capacity: 090 = 900 nf 120 = 1200 nf Line cable current: 06 = 60 A 08 = 85 A Enclosure: E = Increased degree of protection IP65 Version: A = Housing in protection class I B = Housing in protection class II Series and generation: 10 = Standard Type of installation: S = Stationary Component: C = Compensation box Type: T = MOVITRANS Type designation of the TVS connection distributor The type designation of the TVS connection distributor comprises following characteristic data: TVS 10.-E Design of the flange plate/connections: 1 = 4 M25, 2 M32 2 = 2 M32, 2 M32 Compensation capacity: Not installed Line cable current: 06 = 60 A 08 = 85 A Enclosure: E = Increased degree of protection IP65 Version: A = Housing in protection class I B = Housing in protection class II Series and generation: 10 = Standard Type of installation: S = Stationary Component: V = Connection distributor Type: T = MOVITRANS 12 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

13 Unit Design Type designation TLS line cable The type designation of the TLS line cable comprises following characteristic data: T L S 10 E Design: 1 = Standard Number of single cores: 01 = Single-core 06 = Six-core Cable cross section: 006 = 6 mm = 8 mm = 16 mm = 25 mm = 41 mm 2 Line cable design: E = Round Series and generation: 10 = Standard Type of installation: S = Stationary Component: L = High-frequency line cable Type: T = MOVITRANS Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 13

14 3 Unit Design Type designation TIS Installation components The type designation of the TIS installation components comprises following characteristic data: T I S 10 A Design: 0 = Standard Cable bushing: A00 = Grommet A74 = Cable bushing 8 mm 2 Flexible profile section (cable duct), 2.2 m long: F33 = Flexible, installation dimension 33 mm F74 = Flexible, installation dimension 74 mm Support complete (for profile section): H00 = AFT profile 180 H02 = Dürr profiile 180, universal Fixed profile section (cable duct), 3 m long: P33 = Fixed, installation dimension 33 mm P74 = Fixed, installation dimension 74 mm Installation plate (cable bridge): V00 = Straight installation plate with cover Retaining plate (for TCS, TVS and TIS10A008-H02-0): X00 = AFT profile 180 X02 = Dürr 180 XH2 = Universal Cable cross section of the line cable: 008 = 8 mm = 25 mm 2 Version: A Series and generation: 10 = Standard Type of installation: S = Stationary Component: I = Installation equipment Type: T = MOVITRANS 14 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

15 Unit Design Nameplate Nameplate Nameplate of the TCS compensation box The following figure shows an example for a TCS compensation box nameplate: Type Type designation C Compensation capacity I Current T Ambient temperature f Frequency Nameplate of the TVS connection distributor The following figure shows an example of a TVS connection distributor nameplate: Type Type designation f Frequency I Current T Ambient temperature Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 15

16 3 Unit Design Scope of delivery 3.3 Scope of delivery TCS compensation box TCS10A The following components are included in the scope of delivery of the TCS10A compensation box: Compensation box TCS10A-E0X-XXX-1 TCS10A-E0X-XXX-3 Scope of delivery 1 compensation box with blanking plugs installed 2 M8 combi pan head screws, each with lock washer and plain washer 1 M5 combi pan head screw with lock washer and plain washer TCS10B The following components are included in the scope of delivery of the TCS10B compensation box: Compensation box TCS10B-E0X-XXX-1 TCS10B-E0X-XXX-3 Scope of delivery 1 compensation box with blanking plugs installed 2 M8 combi pan head screws, each with lock washer and plain washer 1 M5 combi pan head screw with lock washer and plain washer 1 insulation insert TVS connection distributor TVS10A The following components are included in the scope of delivery of the TVS10A connection distributor for line cable currents of 60 A: Connection distributor Scope of delivery TVS10A-E connection distributor with 4 M25 blanking plugs and 2 M32 blanking plugs installed 1 M5 combi pan head screw with lock washer and plain washer 8 M6 hex nuts 8 jumpers The following components are included in the scope of delivery of the TVS10A connection distributor for line cable currents of 85 A: Connection distributor TVS10A-E TVS10A-E Scope of delivery 1 connection distributor with blanking plugs installed 1 M5 combi pan head screw with lock washer and plain washer 4 hex nuts M8 4 jumpers TVS10B The following components are included in the scope of delivery of the TVS10B connection distributor for line cable currents of 60 A: Connection distributor Scope of delivery TVS10B-E connection distributor with 4 M25 blanking plugs and 2 M32 blanking plugs installed 1 M5 combi pan head screw with lock washer and plain washer 8 M6 hex nuts 8 jumpers 1 insulation insert The following components are included in the scope of delivery of the TVS10B connection distributor for line cable currents of 85 A: Connection distributor TVS10B-E TVS10B-E Scope of delivery 1 connection distributor with blanking plugs installed 1 M5 combi pan head screw with lock washer and plain washer 4 hex nuts M8 4 jumpers 1 insulation insert 16 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

17 Unit Design Scope of delivery TLS line cable/supply cable The following components are included in the scope of delivery of the TLS line cable/ supply cable: Line cable/supply cable TLS10E TLS10E TLS10E TLS10E TLS10E Scope of delivery TLS line cable/supply cable with required length (Specify the required length in meters in your order.) TIS...-V..-0 installation plate The following components are included in the scope of delivery of the TIS...-V..-0 installation plate: Installation plate Scope of delivery TIS10A025-V installation plate with cover 6 rubber studs TIS...-X..-0 retaining plate The following components are included in the scope of delivery of the TIS...-X..-0 retaining plate: Holding plate TIS10A008-X00-0 TIS10A008-X02-0 TIS10A008-XH2-0 Scope of delivery Holding plate with 2 socket head screws M6 25 matching AFT aluminum profile rail 180 (VPE = 10 pieces) Holding plate with 2 socket head screws M6 25 matching Dürr aluminum profile rail (VPE = 10 pieces) 1 universal holding plat for mounting the (universal) holding fixture TIS10A008-H TIS...-H..-0 holding fixture for profile section The following components are included in the scope of delivery of the TIS...-H..-0 holding fixture for profile section: Holding fixture TIS10A008-H00-0 TIS10A008-H02-0 Scope of delivery 1 holding fixture with 2 rotary supports, matching AFT aluminum profile rail (universal) holding fixture with 2 rotary supports matching Dürr aluminum profile rail 180 and TIS10A008-XH2-0 universal holding plate Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 17

18 3 Unit Design Scope of delivery TIS...-P..-0/TIS...-F..-0 profile section The following components are included in the scope of delivery of the TIS...-P..-0 profile section: Holding fixture TIS10A008-P33-0 TIS10A008-P74-0 Scope of delivery 1 fixed profile section, installation dimension 33 mm, 3 m long 1 fixed profile section, installation dimension 74 mm, 3 m long The following components are included in the scope of delivery of the TIS...-F..-0 flexible profile section: Holding fixture TIS10A008-F33-0 TIS10A008-F74-0 Scope of delivery 1 flexible profile section, installation dimension 33 mm, 2.2 m long 1 flexible profile section, installation dimension 74 mm, 2.2 m long TIS...-A..-0 cable bushing The following components are included in the scope of delivery of the TIS...-A..-0 cable bushing: Cable bushing TIS10A008-A00-0 TIS10A008-A74-0 Scope of delivery 1 cable bushing grommet 1 cable entry frame 18 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

19 Unit Design TCS compensation box TCS compensation box Design The following figure shows the TCS compensation box: [2] [3] [1] [3] [2] [1] CS10A / TCS10B compensation box [2] Flange plate 1/2 [3] With TCS10A: PE connection (M5) With TCS10B: Earth connection Blanking plugs The following table provides the number and size of blanking plugs for the two flange plates of the individual compensation boxes, and their protection class. Number and size of blanking plugs Protection Compensation box type Flange plate 1 Flange plate 2 class TCS10A-E I 4xM25 4xM25 TCS10A-E I TCS10A-E x M32 2 x M32 I TCS10B-E II 4xM25 4xM25 TCS10B-E II TCS10B-E x M32 2 x M32 II Other capacities are available on request Function The TCS compensation box is used to compensate the track inductance. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 19

20 3 Unit Design TVS connection distributor 3.5 TVS connection distributor Design The following table shows the TVS connection distributor: [3] [4] [1] [4] [2] [1] TVS10A / TVS10B connection distributor [2] Flange plate 1 [3] Flange plate 2 [4] With TVS10A: PE connection (M5) With TVS10B: Earth connection Blanking plugs The following table provides the number and size of blanking plugs for the two flange plates of the individual connection distributors, and their protection class. Connection distributor Number and size of blanking plugs Protection type Flange plate 1 Flange plate 2 class TVS10A-E I 2xM32 4xM25 TVS10A-E I TVS10A-E x M32 2 x M32 I TVS10B-E II 2xM32 4xM25 TVS10B-E II TVS10B-E x M32 2 x M32 II Function The TVS connection distributor is used to connect the TLS supply cable (supply cabinet energy transmission line). Couple the TLS line cables to the power transmission system. 20 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

21 Unit Design TLS line cable/supply cable TLS line cable/supply cable Design The following figure shows the TLS line cable/supply cable: [1] [2] [3] [4] [1] TLS10E line cable (cable cross section 8 mm 2 ) [2] TLS10E line cable (cable cross section 16 mm 2 ) [3] TLS10E / TLS10E line cables (cable cross section 25 mm 2 / 41 mm 2 ) [4] TLS10E supply cable (cable cross section 6 6 mm 2 ) Function TLS10E line cable: Medium-frequency cable for THM pick-up Routed as current loop in plastic profile section system TLS10E line cable: Medium-frequency cable for THM pick-up Routed on or in the floor TLS10E /TLS10E line cable: Medium-frequency cable for THM pick-up Routed as current loops in or on the floor TLS10E supply cable: Fine litz wires as supply cable from supply cabinet power transmission system Fixed installation, e.g. in cable duct or as a cable carrier application Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 21

22 3 Unit Design TIS10...-V..-0 installation plate 3.7 TIS10...-V..-0 installation plate design The following figure shows the TIS...-V..-0 installation plate: [3] [2] [1] [1] TIS10A025-V00-0 installation plate [2] Cover [3] Rubber studs Function The TIS installation plates are mounted to the floor along the straight transmission line. The TLS line cable with a 25 mm 2 cross section and a 60 A or 85 A line cable current is inserted into the TIS installation plate. 22 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

23 Unit Design TIS...-X..-0 retaining plate TIS...-X..-0 retaining plate Design The following figure shows the TIS...-X..-0 retaining plate: [1] [2] [3] [1] TIS10A008-X00-0 retaining plate matching AFT aluminum profile rail 180 [2] TIS10A008-X02-0 reatining plate matching Dürr aluminum profile rail 180 [3] TIS10A008-XH2-0 universal retaining plate for mounting the TIS10A008-H02-0 (universal) holding fixture Function The TIS...-X..-0 retaining plate is used to mount a TCS compensation box or a TVS connection distributor to an aluminum profile rail. There are correspondingly adjusted retaining plates available for the different aluminum profiles. The TIS...-X..-0 retaining plate is delivered with two M6x25 socket head screws. The TIS...-XH2-0 universal retaining plate is used to mount the TIS...-H02-0 (universal) holding fixture to an aluminum or steel construction. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 23

24 3 Unit Design TIS...-H..-0 holding fixture 3.9 TIS...-H..-0 holding fixture Design The following figure shows the TIS...-H..-0 holding fixture: [1] [2] [1] TIS10A008-H00-0 holding fixture matching AFT profile 180 [2] TIS10A008-H02-0 (universal) holding fixture matching Dürr profile 180 and TIS10A008- XH2-0 universal retaining plate Function The TIS...-H..-0 holding fixture is used to mount the TIS...-P..-0 / TIS...-F..-0 profile section. 24 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

25 Unit Design TIS...P..-0 rigid profile section TIS...P..-0 rigid profile section Design The following figure shows the TIS...-P..-0 rigid profile section: [1] [2] [1] TIS10A008-P33-0 rigid profile section [2] TIS10A008-P74-0 rigid profile section Function The TIS...-P..-0 profile section (cable duct) in rigid design supports the TLS line cable preferably for straight sections. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 25

26 3 Unit Design TIS...-F..-0 flexible profile section 3.11 TIS...-F..-0 flexible profile section Design The following figure shows the TIS...-F..-0 flexible profile section: [1] [2] [1] TIS10A008-F33-0 flexible profile section [2] TIS10A008-F74-0 flexible profile section Function The profile section TIS...-F..-0 in flexible design supports the TLS line cable preferably for curved sections. 26 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

27 Unit Design TIS...-A..-0 cable bushing TIS...-A..-0 cable bushing Design The following figure shows the TIS...-A..-0 cable bushing: [1] [2] [1] TIS10A008-A00-0 cable bushing grommet [2] TIS10A008-A74-0 cable bushing grommet Function You use the cable bushing TIS...-A..-0 in case you have to interrupt the transmission line. A transmission line is interrupted: In the point area of a transmission line. In case of connection to a TCS compensation box or an TVS connection distributor. At the end of a transmission line (track termination). Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 27

28 4 Installation General information 4 Installation 4.1 General information WARNING Faulty installation. Severe or fatal injuries. It is essential to comply with the safety notes in chapter 2 during installation. 4.2 Prefabrication of the TLS line cable Tools The following figure shows tools suitable for prefabricating TSL line cables: [1] [2] [3] [4] [5] [6] [1] Diagonal cutter [4] Soldering pot with solder [2] Knife [5] Hatchet-type soldering iron (min. 300 W) with solder [3] Shrink tubing [6] Vise 28 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

29 Installation Prefabrication of the TLS line cable Cable type The TLS line cables are medium-frequency cables. The core of the medium-frequency cable consists of numerous thin wires that are insulated from each other by a coating Procedure The TLS line cable ends are soldered to a cable lug during prefabrication. Do not press the cable lugs. We recommend a soldering pot and a hatchet-type soldering iron for soldering the cable lugs. To prefabricate the TLS line cables proceed as follows: 1. Push the shrinking tube over the cable end. 2. Mark the length you want to strip Remove the insulation at the end of the cable Remove the insulation (coating) of the individual wires and solder the cable lug. You have the following options: Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 29

30 4 Installation Prefabrication of the TLS line cable A With hatched-type soldering iron: Pour the solder into the cable lug to halfway. Insert the stripped cable end in the cable lug. Heat the cable lug with the hatchet-type soldering iron until the insulation of the individual wires melts and leaks out of the cable lug as brown waste B With soldering pot and hatchet-type soldering iron: WARNING Danger of burns due to hot solder. Severe injuries Wear heat-resistant gloves during soldering activities with soldering pot and hatchet-type soldering iron. Hold the stripped cable end in the soldering pot until the insulation of the individual wires melts and floats to the top of the soldering cup. When the wires expand, you can wipe them off with a heat-resistant cloth and put them into shape again. Pour the solder into the cable lug to halfway. Insert the cable end in the cable lug. Heat the cable lug with the hatchet-type soldering iron again Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

31 Installation Prefabrication of the TLS line cable 4 C With gas flame: Pour the solder into the cable lug to halfway. Insert the stripped cable end in the cable lug. Heat the cable lug with the gas flame until the insulation of the individual wires melts and leaks out of the cable lug as brown waste. Make sure that the insulation (coating) of the individual wires melts and leaks out of the cable lug during soldering! This is essential for a good connection with low contact resistance. 5. Push the shrinking tube over the soldering point. 6. Heat the shrink tubing until it closes tightly around the soldering point Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 31

32 4 Installation Prefabrication of the TLS supply cable 4.3 Prefabrication of the TLS supply cable Cable type The TLS supply cable is a six-core cable. There are 3 blue cores and 3 black ones. In the supply cable, the conductor wires are not insulated against one another. Three cores of the same color are used as outgoing cables or return cables Procedure To prefabricate the TLS supply cable proceed as follows: Using a standard tool, press each core end together with a ring cable lug. For cable lug types, refer to section "Technical data/tls line cable/tls supply cable" (page 46) 4.4 Connecting the TLS line cable to the TCS compensation box Procedure for the TCS10A compensation box Proceed as follows to connect the TLS line cable to the TCS compensation box: 1. Remove the blanking plugs according to the number of TLS line cables to be connected. 2. Insert the correct number of M25/M32 cable glands in place of the blanking plugs. 3. Open the TCS10A compensation box. To do so, remove the four M5 hex head screws from the housing cover. 4. Insert the prefabricated TLS line cable through the cable gland into the wiring space of the TCS10A compensation box. 5. Connecting the TLS line cable to TCS10A: Remove the two M8 combi pan head screws from the connector plate of the TCS10A compensation box. Connect the TLS line cables prefabricated with cable lugs to the terminal studs. Screw the two combi pan head screws back into the terminal studs. The following figure shows the TLS line cable connected to the TCS10A compensation box: Attach the housing cover and the gasket using the four M5 hex head screws. 7. Make sure that the gasket is properly seated and the screws are securely tightened to ensure degree of protection IP Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

33 Installation Connecting the TLS line cable to the TCS compensation box Procedure for the TCS10B compensation box Proceed as follows to connect the TLS line cable to the TCS10B compensation box: 1. Remove the blanking plugs according to the number of TLS line cables to be connected. 2. Insert the correct number of M25/M32 cable glands in place of the blanking plugs. 3. Open the TCS10B compensation box. To do so, remove the four M5 hex head screws from the housing cover. 4. Remove the insulation insert. 5. Insert the prefabricated TLS line cable through the cable gland into the wiring space of the TCS10B compensation box. 6. Connecting the TLS line cable to TCS10B: Remove the two M8 combi pan head screws from the connector plate of the TCS10B compensation box. Connect the TLS line cables prefabricated with cable lugs to the terminal studs. Loosely screw the two combi pan head screws back into the terminal studs. Connect the TLS line cables with a cable tie. Securely tighten the two combi pan head screws. The following figure shows the TLS line cable connected to the TCS10B compensation box [1]: [4] [3] [2] [1] [1] TCS10B compensation box [3] Insulation insert [2] Nomex paper [4] Housing cover Install the insulation insert [3]. Make sure that the Nomex paper [2] is fitted between insulation insert and inner wall of the housing. 8. Attach the housing cover [4] and the gasket using the four M5 hex head screws. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 33

34 4 Installation Connecting the TLS line cable to the TVS connection distributor 9. Make sure that the gasket is properly seated and the screws are securely tightened to ensure degree of protection IP Connecting the TLS line cable to the TVS connection distributor Procedure for the TVS10A compensation box Do the following to connect the TLS line cable to the TVS 10A connection distributor: 1. Remove the blanking plugs according to the number of TLS line cables to be connected. 2. Insert the correct number of M25/M32 cable glands in place of the blanking plugs. 3. Open the TVS10A connection distributor. To do so, remove the four M5 hex head screws from the housing cover. 4. Insert the prefabricated TLS line cable through the cable gland into the wiring space of the TVS10A connection distributor. 5. Connecting the TLS line cable to TVS10A: On the terminal board, unscrew the M6/M8 hex nuts from the connection stud bolts. The number of nuts to be removed depends on the number of TLS line cables to be connected. Connect the jumpers according to the circuit diagram. Connect the TLS line cables prefabricated with cable lugs to the connection stud bolts on the terminal board. Screw the M6/M8 hex nuts onto the connection stud bolts. The following figure shows the TLS line cable connected to the TVS10A connection distributor: 60 A A Attach the housing cover and the gasket using the four M5 hex head screws. 7. Make sure that the gasket is properly seated and the screws are securely tightened to ensure degree of protection IP Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

35 Installation Connecting the TLS line cable to the TVS connection distributor Procedure for the TVS10B compensation box Do the following to connect the TLS line cable to the TVS10B connection distributor: 1. Remove the blanking plugs according to the number of TLS line cables to be connected. 2. Insert the correct number of M25/M32 cable glands in place of the blanking plugs. 3. Open the TVS10B connection distributor. To do so, remove the four M5 hex head screws from the housing cover. 4. Remove the insulation insert. 5. Insert the prefabricated TLS line cable through the cable gland into the wiring space of the TVS10B connection distributor. 6. Connecting the TLS line cable to TVS10B: On the terminal board, unscrew the M6/M8 hex nuts from the connection stud bolts. The number of nuts to be removed depends on the number of line cables to be connected. Connect the jumpers according to the circuit diagram. Connect the TLS line cables prefabricated with cable lugs to the connection stud bolts on the terminal board. Loosely screw the M6/M8 hex nuts onto the connection stud bolts. Join the TLS line cables using a cable tie. Securely tighten the M6 / M8 hex nuts. The following figure shows the TLS line cable connected to the TVS10B connection distributor: 60 A A Install the insulation insert. Make sure that the Nomex paper is fitted between insulation insert and inner wall of the housing. 8. Attach the housing cover and the gasket using the four M5 hex head screws. 9. Make sure that the gasket is properly seated and the screws are securely tightened to ensure degree of protection IP65. Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 35

36 4 Installation Connecting the TLS supply cable to the TVS connection distributor 4.6 Connecting the TLS supply cable to the TVS connection distributor Procedure for the TVS10A compensation box To connect the TLS supply cable to the TVS connection distributor, proceed as follows: 1. Remove a blanking plug (M32) from the TVS connection distributor. 2. Insert an M32 cable gland in place of the blanking plug. 3. Open the TVS10A connection distributor. To do so, remove the four M5 hex head screws from the housing cover. 4. Press a ring cable lug (6 mm 2 with 6 mm hole) onto each of the 6 cores of the supply cable. 5. Insert the supply cable that is prefabricated with cable lugs through the cable gland and into the wiring space of the TVS10A connection distributor. 6. Connecting the TLS supply cable to TVS10A: On the terminal board, unscrew the M6 hex nuts from the connection stud bolts. The number of nuts to be removed depends on the number of TLS line cables to be connected. Connect the jumpers according to the circuit diagram. Connect 3 cores of the supply cable that are the same color, prefabricated with cable shoes, to the connection stud bolts on the terminal board. Screw the M6 hex nuts back onto the connection stud bolts. The following figure shows the TLS supply cable connected to the TVS10A connection distributor: Attach the housing cover and the gasket using the four M5 hex head screws. 8. Make sure that the gasket is properly seated and the screws are securely tightened to ensure degree of protection IP Procedure for the TVS10B compensation box Do the following to connect the TLS supply cable to the TVS10B connection distributor: 1. Remove one blanking plug (M32) from the connection distributor. 2. Insert an M32 cable gland in place of the blanking plug. 3. Open the TVS10B connection distributor. To do so, remove the four M5 hex head screws from the housing cover. 4. Remove the insulation insert. 5. Press a ring cable lug (6 mm 2 with 6 mm hole) onto each of the 6 cores of the supply cable. 6. Insert the supply cable that is prefabricated with cable lugs through the cable gland and into the wiring space of the TVS10B connection distributor. 36 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

37 Installation Eartch connection of the compensation box / connection distributor 4 7. Connecting the TLS supply cable to TVS10B: On the terminal board, unscrew the M6 hex nuts from the connection stud bolts. The number of nuts to be removed depends on the number of TLS line cables to be connected. Connect the jumpers according to the circuit diagram. Connect 3 cores of the TLS supply cable that are the same color, prefabricated with cable shoes, to the connection stud bolts on the terminal board. Screw the M6 hex nuts back onto the connection stud bolts. Join the supply wires (3 blue, 3 black) with one cable tie each. The following figure shows the TLS supply cable connected to the TVS10B connection distributor: Install the insulation insert. Make sure that the Nomex paper is fitted between insulation insert and inner wall of the housing. 9. Attach the housing cover and the gasket using the four M5 hex head screws. 10.Make sure that the gasket is properly seated and the screws are securely tightened to ensure degree of protection IP Eartch connection of the compensation box / connection distributor Guidelines The TCS10A compensation box and the TVS10A connection distributor are qualified as equipment of protection class I. Comply with following directives when grounding the TCS10A compensation box and the TVS10A connection distributor: Ground the unit using the shortest possible route. Use a green/yellow grounding cable Procedure Proceed as follows to ground the TCS10A compensation box and the TVS10A connection distributor: 1. Connect the earth connection (cable cross section 16 mm 2 ) to the local ground potential (e.g. to an aluminum rail of overhead trolley systems) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 37

38 4 Installation Eartch connection of the compensation box / connection distributor [1] [2] [1] Flange plate (different connections depending on type) [2] Earth connection 38 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

39 Installation Earth connection of compensation box / connection distributor Earth connection of compensation box / connection distributor Guidelines The TCS10B compensation box and the TVS10B connection distributor are qualified as equipment of protection class II. If there is a risk of external voltage, for example by a 50/60 Hz line voltage, you may connect the earth connection (chassis) to the local equipotential bonding. Comply with the following guideline when establishing the earth connection for the TCS10B compensation box and the TVS10B connection distributor: Route the earth connection by the shortest possible route Procedure in the event of external voltage Do the following to establish earth connection for the TCS10B compensation box and the TVS10B connection distributor: 1. Connect the earth connection with the local equipotential bonding. [1] [2] [1] Flange plate (different connections depending on type) [2] Earth connection Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 39

40 4 Installation Installing the TIS10A equipment 4.9 Installing the TIS10A equipment Guidelines The TIS10A008.. installation equipment (holding fixtures, profile sections, retaining plates, cable bushings) are suitable for installation on aluminum profile rails (e.g. overhead trolley systems) or universal installation on machines. Use an aluminum shielding plate for installation on a steel construction. Comply with the following guidelines for installation on aluminum profile rails and universal installation: Following TIS...-H..-0 holding fixtures are required for the secure mounting of the TIS...-P..-0/TIS...-F..-0 profile sections: Profile sections For straight segments: TIS...-P..-0 rigid profile section For curves: TIS...-F..-0 flexible profile section Number of required holding fixtures 2 pieces/meter 1 piece/termination 3 pieces/meter 1 piece/termination NOTICE Deflection of the profile section due to material expansion in the event of high temperature differences. Longitudinal extension might cause undulated deformation. Install the individual profile sections leaving a 10 mm (0.4 in) gap in between. TIS 10A008-H02-0, TIS 10A008-XH2-0 TIS 10A008-P74-0 / TIS 10A008-F74-0 TIS 10A008-P33-0 / TIS 10A008-F33-0 Profile section (straight or curve) 10 mm (0.4 in) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

41 Installation Installing the TIS10A equipment Procedure Proceed as follows for the installation on aluminum profile rails and for universal installation: 1. Insert the TIS...-H..-0 holding fixtures into the aluminum profile rail (or into the TIS...- XH2-0 universal retaining plate for universal installation). Install a holding fixture at the start and another one at the end for each transmission line. On straight tracks, there is a distance of ca. 50 cm between the holding fixtures. In curves, the distance is ca. 33 cm. 2. Ensure that all of the holding fixtures' screw plugs are open. 3. Press the TIS...-P..-0/TIS...-F..-0 profile sections into the TIS...-H..-0 holding fixtures until they snap (see fig.[a]). 4. Adjust the TIS...-P..-0/TIS...-F..-0 profile sections Observe the distances due to material expansion (see guidelines (page 40)). 5. Close the screw plugs of the TIS...-H..-0 holding fixtures (see fig. [B]). [A] [B] [1] [2] [3] [4] [1] [2] [3] [4] [1] Aluminum profile rail (for universal installation: Construction with TIS10A008-XH2-0 universal retaining plate) [2] TIS...-H..-0 holding fixture [3] Screw plug [4] TIS...-P..-0/TIS...-F..-0 profile section Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 41

42 4 Installation Installing the TIS10A equipment Installation on aluminum profile rail The following figure shows the TIS10A008...installation equipment mounted to an aluminum profile rail: [A] [B] [1] [2] [9] [3] [4] [5] [6] [7] [8] [9] [A] [B] Installation of a TCS compensation box/tvs connection distributor Installation of the entire TIS profile section system [1] TIS10A008-X...-0 retaining plate matching aluminum profile rail [2] TIS10A008-A00-0 cable bushing grommet [3] TIS10A008-A74-0 cable bushing frame for line cable 8 mm 2 [4] TIS10A008-H...-0 holding fixture matching aluminum profile rail [5] TIS10A008-P74-0 rigid profile section [6] TIS10A008-P33-0 rigid profile section [7] TIS10A008-F33-0 flexible profile section [8] TIS10A008-F74-0 flexible profile section [9] Aluminum profile rail (not included in the scope of delivery) Installation dimension The following figure shows the installation dimension of the installed profile section system (dimensions in mm (in)): 33 (1.3) 74 (2.9) 33 (1.3) 74 (2.9) 180 (7.09) [A] [B] [A] [B] Installation dimension for AFT profile 180 with matching holding fixture (...-H00-0) and profile section Installation dimension for Dürr profile 180 with matching holding fixture (...H02-0) and profile section 42 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

43 Installation Installing the TIS10A equipment 4 Universal installation The following figure shows the installation equipment TIS10A mounted to an aluminum construction [A] and to a steel construction [B]: [1] [A] [2] [3] [9] [4] [5] [6] [7] [B] [3] [9] [4] [5] [6] [7] [8] [A] [B] Installation on an aluminum construction Installation on a steel construction [1] TIS10A008-A00-0 cable bushing grommet [2] TIS10A008-A74-0 cable bushing frame for line cable 8 mm 2 [3] TIS10A008-H02-0 (universal) holding fixture matching Dürr aluminum profile rail 180 and TIS10A008-XH2-0 universal retaining plate [4] TIS10A008-P74-0 rigid profile section [5] TIS10A008-P33-0 rigid profile section [6] TIS10A008-F33-0 flexible profile section [7] TIS10A008-F74-0 flexible profile section [8] Shielding plate for installation on a steel construction (not included in the delivery) [9] TIS10A-008-XH2-0 universal retaining plate for TIS10A008-H02-0 (universal) holding fixture Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 43

44 4 Installation Installing the TIS10A equipment Installation dimension The following figure shows the installation dimension of the installed profile section system with a TIS10008-XH2-0 retaining plate for the TIS10A008-H02-0 (universal) holding fixture (dimensions in mm (in)): 33 (1.3) 74 (2.9) 74 (2.9) 33 (1.3) 120 (4.72) [A] [B] [A] [B] Installation dimension for installation on aluminum construction Installation dimension for installation on steel construction with shielding plate 44 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

45 Disposal 5 5 WARNING Loss of preventive measure (protective insulation) for TCS10B / TVS10B while operating the system in the event of flooding of the compensation box / connection distributor. Severe or fatal injuries. Immediately switch off the system. Never put a damaged system into operation. Procedure in the event of flooding 1. Immediately switch off the system. 2. Leave the system switched off when removing the flooding. 3. Request electrically qualified personnel to check the interior of each TCS10B compensation box and each TVS10B connection distributor for dryness and intactness of electric contacts, in particular of housings installed in the floor. 4. Do not take the system into operation until this check has been carried out successfully. 5.1 Disposal Observe the latest national regulations in effect! Dispose of materials separately in accordance with the regulations in force, for example: Electronics scrap Plastics Sheet metal Copper Aluminum Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 45

46 6 kva i P n f Hz Technical Data Applicable standards and directives 6 Technical Data 6.1 Applicable standards and directives The development and verification of the MOVITRANS TCS10B compensation box and the MOVITRANS TVS10B connection distributor is based on the following standards: EN Protection against electric shock, chapter 7.3 Protection class II equipment EN /2 Graphical symbols for use on equipment EN Safety of machinery, chapter 8 equipotential bonding 6.2 Certifications The following table shows the valid approvals for MOVITRANS components: Component Type Approval Supply cable TLS10E UL, CSA Line cable TLS10E UL Line cable TLS10E UL Line cable TLS10E UL Line cable TLS10E UL Profile section TIS10A...-P..-0/TIS...-F..-0 UL94-V0 Holding fixtures for profile UL94-V0 E, UL94-V0 TIS10A...-H..-0 section Cable bushing frame TIS10A...-A..-0 UL94-V0 6.3 TLS line cable/supply cable Mechanical properties The following table shows the mechanical properties of the TLS line cable/supply cable: Line cable type Cable cross section Outer diameter Installation type Bending radius [mm 2 ] [mm] [mm] TLS10E ±0.3 Fixed or flexible 80 TLS10E ± TLS10E ± Fixed TLS10E ± TLS10E ± Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

47 Technical Data TLS line cable/supply cable kva i P n f Hz Electrical properties The following table shows the electrical properties of the TLS line cable/supply cable: Line cable type TLS10E Insulation/sheathing material 1) Electrical cable losses per track meter Electrical cable losses 1) Operating voltage [mm 2 ] [W/m] [V] 15 (bei 60 A) (at 60 A) TLS10E Thermoplast / Polyurethane 20 (at 60 A) (2 parallel cables) TLS10E TLS10E (at 60 A) 25 (at 85 A) 1000 TLS10E (at 85 A) Data for connecting the TLS line cable/supply cable with terminal stud M8 The following tables show the data for connecting the TLS line cable/supply cable to the following components using M8 terminal studs: TCS compensation box TVS10.-E connection distributor TAS10A040 transformer module With UL approval The following table shows the data for cable lugs with UL approval: Line cable type Cable lug (with UL approval) Use Cable gland Clamping area Type Width [mm] (Plastic) [mm] TLS10E Klauke 1R/6 12 TAS10A040 M TLS10E Klauke 3R/8 15 TCS M TLS10E Klauke 4R/8 16 TCS TLS10E Klauke 6SG/8 TVS10.-E08 17 TLS10E Klauke 7SG/8 TAS10A040 M25 M Without UL approval The following table shows the data for cable lugs without UL approval: Line cable type Cable lug (without UL approval) Use Cable gland Clamping area Type Width [mm] (Plastic) [mm] TLS10E Klauke TAS10A040 M TLS10E Klauke 702F8 16 TCS M TLS10E Klauke 705F8 18 TCS TLS10E Klauke 706F8 21 TVS10.-E08 M TAS10A040 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 47

48 6 kva i P n f Hz Technical Data TLS line cable/supply cable Data for connecting the TLS line cable/supply cable with terminal stud M6 The following tables show the data for connecting the TLS line cable/supply cable to the TVS10.-E connection distributor with M6 terminal studs. With UL approval The following table shows the data for cable lugs with UL approval: Line cable type Cable lug (with UL approval) Cable glands Clamping area Type Width [mm] (Plastic) [mm] TLS10E Klauke 1R/6 12 M TLS10E Klauke 3R/6 12 M TLS10E Klauke 4R/6 14 M25 TLS10E Klauke 6SG/6 15 M Without UL approval The following table shows the data for cable lugs without UL approval: Line cable type Cable lug (without UL approval) Cable glands Clamping area Type Width [mm] (Plastic) [mm] TLS10E Klauke M TLS10E Klauke 702F6 12 M TLS10E Klauke 705F6 17 M25 M Data for connecting the TLS line cable/supply cable with terminal stud M10 The following table shows the data for the connection of the TLS line cable/supply cable to the TAS10A160 transformer module with M10 terminal studs. With UL approval The following table shows the data for cable lugs with UL approval: Line cable type Cable lug (with UL approval) Type Width [mm] TLS10E Klauke 1R/10 17 TLS10E Klauke 4R/10 18 TLS10E Klauke 6SG/10 19 TLS10E Klauke 7SG/10 19 Without UL approval The following table shows the data for cable lugs without UL approval: Line cable type Cable lug (without UL approval) Type Width [mm] TLS10E Klauke TLS10E Klauke 705F10 18 TLS10E Klauke 706F Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

49 Dimension Sheets TCS10A / TCS10B compensation box kva i P n f Hz 7 7 Dimension Sheets 7.1 TCS10A / TCS10B compensation box The following figure shows the dimension drawing of the TCS10A / TCS10B compensation box, dimensions in mm (in): (0.26) 76 (3.0) 100 (3.94) (0.2) 100 (3.94) (4.547) [A] [B] 210 (8.27) 227 (8.94) 240 (9.45) [A] Flange plate 1 [B] Flange plate TCS...-1 blanking plugs The following figure shows the dimension drawing of the TCS...-1 blanking plugs, dimensions in mm (in): [A] [B] 80 (3.1) 80 (3.1) 35 (1.4) (4x) M25 x 1.5 (4x) M25 x (1.4) 38 (1.5) 38 (1.5) [A] Flange plate 1 [B] Flange plate 2 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 49

50 7 kva i P n f Hz Dimension Sheets TVS10A / TVS10B connection distributor TCS...-3 blanking plugs The following figure shows the dimension drawing of the TCS...-3 blanking plugs, dimensions in mm (in): 80 (3.1) [A] (2x) M32 x 1.5 (2x) M32 x 1.5 [B] 80 (3.1) 45 (1.8) 45 (1.8) [A] Flange plate 1 [B] Flange plate TVS10A / TVS10B connection distributor The following figure shows the dimension drawing of the TVS10A / TVS10B connection distributor, dimensions in mm (in): 6.5 (0.26) 76 (3.0) 100 (3.94) 5 (0.2) 100 (3.94) (4.547) [A] [B] 210 (8.27) 227 (8.94) 240 (9.45) [A] Flange plate 1 [B] Flange plate 2 50 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

51 Dimension Sheets TVS10A / TVS10B connection distributor kva i P n f Hz TVS...-1 blanking plugs The following figure shows the dimension drawing of the TVS...-1 blanking plugs, dimensions in mm (in): [A] [B] 80 (3.1) 75 (3.0) 35 (1.4) (4x) M25 x 1.5 (2x) M32 x (1.6) (1.5) (1.3) [A] Flange plate 1 [B] Flange plate TVS...-2 blanking plugs The following figure shows the dimension drawing of the TVS...-2 blanking plugs, dimensions in mm (in): 80 (3.1) [A] (2x) M32 x 1.5 (2x) M32 x 1.5 [B] 80 (3.1) 45 (1.8) 45 (1.8) [A] Flange plate 1 [B] Flange plate 2 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 51

52 7 kva i P n f Hz Dimension Sheets TIS...-V..-0 installation plate 7.3 TIS...-V..-0 installation plate TIS10A025-V00-0 installation plate The following figure shows the dimension drawing of the TIS10A025-V00-0 installation plate, dimensions in mm (in): 500 (19.7) 350 (13.8) 28 (1.1) 25 (0.98) 250 (9.84) 500 (19.7) 340 (13.4) 250 (9.84) 240 (9.45) 140 (5.51) 100 (3.94) 15 (0.59) 17 (0.67) Ø 14 Ø 18 (Ø 0.55) (Ø 0.71) The figure below shows the dimension drawing of the cover of the TIS10A025-V00-0 installation plate, dimensions in mm (in): (19.7) (13.8) 3 (0.1) (14.8) (9.84) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

53 Dimension Sheets TIS...-X..-0 retaining plate kva i P n f Hz TIS...-X..-0 retaining plate TIS10A008-X00-0 retaining plate The following figure shows the dimension drawing of the TIS10A008-X00-0 retaining plate (matching the ATF profile 180), dimensions in mm (in): (0.63) 18 (0.71) (0.226) (4.311) 76 (3.0) M6 Ø5.5 (Ø0.22) 92.5 (3.64) TIS10A008-X02-0 retaining plate The following figure shows the dimension drawing of the TIS10A008-X02-0 retaining plate (matching the Dürr profile 180), dimensions in mm (in): M (6.06) (3.0) Ø5.5 (Ø0.22) 15.3 (0.602) 4.6 (0.18) 25 (0.98) (3.65) (4.748) (5.488) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 53

54 7 kva i P n f Hz Dimension Sheets TIS...-X..-0 retaining plate TIS10A008-XH2-0 universal retaining plate The following figure shows the dimension drawing of the TIS10A008-XH2-0 universal retaining plate (matching the TIS10A008-H02-0 holding fixture), dimensions in mm (in): 145 (5.71) 130 (5.12) 75 (3.0) 45 (1.8) 60 (2.4) Ø5.5 (Ø0.22) 45 (1.8) 154 (6.06) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

55 Dimension Sheets TIS...-H..-0 holding fixture kva i P n f Hz TIS...-H..-0 holding fixture TIS10A008-H00-0 holding fixture The following figure shows the dimension drawing of the TIS10A008H00-0 holding fixture (matching the ATF profile 180), dimensions in mm (in): 160 (6.30) 100 (3.94) 50 (2.0) 40 (1.6) 120 (4.72) (0.55) (0.75) (0.91) TIS10A008-H02-0 holding fixture The following figure shows the dimension drawing of the TIS10A008-H02-0 holding fixture (matching the Dürr profile 180 and universal retaining plate), dimensions in mm (in): (6.047) 100 (3.94) 50 (2.0) 40 (1.6) 120 (4.72) (0.43) (0.55) (0.75) TIS...-P..-0 rigid profile section TIS10A008-P33-0 profile section The following figure shows the dimension drawing of the TIS10A008-P33-0 profile section, dimensions in mm (in): 18.1 (0.713) (0.6083) +0.2 ( ) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 55

56 7 kva i P n f Hz Dimension Sheets TIS...-F..-0 flexible profile section TIS10A008-P74-0 profile section The following figure shows the dimension drawing of the TIS10A008-P74-0 profile section, dimensions in mm (in): 15,09 (0.5941) ( ) 59,47 (2.341) TIS...-F..-0 flexible profile section TIS10A008-F33-0 profile section The following figure shows the dimension drawing of the TIS10A008-F33-0 profile section, dimensions in mm (in): (0.6083) (0.4390) 2200 (86.61) 4 (0.2) 18.1 (0.713) x39.29 (1.468) (54x1.547) TIS10A008-F74-0 profile section The following figure shows the dimension drawing of the TIS10A008-F74-0 profile section, dimensions in mm (in): (0.5941) 2200 (86.61) 4 (0.2) (2.341) 50 (2.0) x39.29 (1.607) (54x1.547) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

57 Dimension Sheets TIS...-A..-0 cable bushing kva i P n f Hz TIS...-A..-0 cable bushing Cable bushing grommet TIS10A008-A00-0 The following figure shows the dimension drawing of the TIS10A008-A00-0 cable bushing grommet, dimensions in mm (in): Ø13 (Ø0.51) 3(0.1) 8(0.3) 14 (0.55) Ø9.5 (Ø0.37) Ø17.5 (Ø0.689) TIS10A008-A74-0 cable bushing frame The following figure shows the dimension drawing of the TIS10A008-A74-0 cable bushing frame, dimensions in mm (in): 74 (2.9) 8.5 (0.33) Ø11.8 (Ø0.465) Ø11.8 (Ø0.465) 55.5 (2.19) (1.4) (0.55) 70.5 (2.78) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 57

58 7 kva i P n f Hz Dimension Sheets Shielding plate 7.9 Shielding plate The shielding plate is not included in the scope of delivery. It is mandatory that you make the shielding plate of aluminum. The following figure shows the dimension drawing of the shielding plate, dimensions in mm (in): Ø 10.5 (Ø 0.413) Ø 5.5 (Ø 0.22) R15 (R0.59) 220 (8.66) 150 (5.91) 130 (5.12) (0.1) 25 (0.98) 220 (8.66) 60 (2.4) 500 (19.7) 720 (28.3) 60 (2.4) 975 (38.4) 1000 (39.37) 120 (4.72) Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

59 Address List 8 8 Address List Germany Headquarters Production Production / Industrial Gears Competence Center Bruchsal Bruchsal Central North East South West SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Straße 42 D Bruchsal P.O. Box Postfach 3023 D Bruchsal SEW-EURODRIVE GmbH & Co KG Christian-Pähr-Str.10 D Bruchsal SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Straße 1 D Graben-Neudorf SEW-EURODRIVE GmbH & Co KG Alte Ricklinger Straße D Garbsen (near Hannover) SEW-EURODRIVE GmbH & Co KG Dänkritzer Weg 1 D Meerane (near Zwickau) SEW-EURODRIVE GmbH & Co KG Domagkstraße 5 D Kirchheim (near München) SEW-EURODRIVE GmbH & Co KG Siemensstraße 1 D Langenfeld (near Düsseldorf) Electronics SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Straße 42 D Bruchsal Drive Hotline / 24 Hour Additional addresses for service in Germany provided on request! Tel Fax sew@sew-eurodrive.de Tel Fax Tel Fax sc-mitte@sew-eurodrive.de Tel Fax sc-nord@sew-eurodrive.de Tel Fax sc-ost@sew-eurodrive.de Tel Fax sc-sued@sew-eurodrive.de Tel Fax sc-west@sew-eurodrive.de Tel Fax sc-elektronik@sew-eurodrive.de SEWHELP euro cents/min on the German landline network. Max 42 euro cents/min from a German mobile network. Prices for mobile and international calls may differ. France Production Haguenau SEW-USOCOME route de Soufflenheim B. P F Haguenau Cedex Production Forbach SEW-USOCOME Zone industrielle Technopôle Forbach Sud B. P F Forbach Cedex Bordeaux Lyon SEW-USOCOME Parc d'activités de Magellan 62 avenue de Magellan - B. P. 182 F Pessac Cedex SEW-USOCOME Parc d'affaires Roosevelt Rue Jacques Tati F Vaulx en Velin Tel Fax sew@usocome.com Tel Tel Fax Tel Fax Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 59

60 8 Address List France Nantes Paris SEW-USOCOME Parc d activités de la forêt 4 rue des Fontenelles F Le Bignon SEW-USOCOME Zone industrielle 2 rue Denis Papin F Verneuil I'Etang Additional addresses for service in France provided on request! Tel Fax Tel Fax Algeria Alger REDUCOM Sarl 16, rue des Frères Zaghnoune Bellevue El Harrach Alger Tel Fax info@reducom-dz.com Argentina Buenos Aires SEW EURODRIVE ARGENTINA S.A. Centro Industrial Garin, Lote 35 Ruta Panamericana Km 37, Garin Tel Fax sewar@sew-eurodrive.com.ar Australia Melbourne SEW-EURODRIVE PTY. LTD. 27 Beverage Drive Tullamarine, Victoria 3043 Tel Fax enquires@sew-eurodrive.com.au Sydney SEW-EURODRIVE PTY. LTD. 9, Sleigh Place, Wetherill Park New South Wales, 2164 Tel Fax enquires@sew-eurodrive.com.au Austria Wien SEW-EURODRIVE Ges.m.b.H. Richard-Strauss-Strasse 24 A-1230 Wien Tel Fax sew@sew-eurodrive.at Belarus Minsk SEW-EURODRIVE BY RybalkoStr. 26 BY Minsk Tel / Fax sales@sew.by Belgium Brussels SEW-EURODRIVE Researchpark Haasrode 1060 Evenementenlaan 7 BE-3001 Leuven Tel Fax info@sew-eurodrive.be Competence Center Industrial Gears SEW-EURODRIVE Rue de Parc Industriel, 31 BE-6900 Marche-en-Famenne Tel Fax service-wallonie@sew-eurodrive.be Brazil Production Sao Paulo SEW-EURODRIVE Brasil Ltda. Avenida Amâncio Gaiolli, Rodovia Presidente Dutra Km 208 Guarulhos SP SAT - SEW ATENDE Tel Fax sew@sew.com.br 60 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

61 Address List 8 Bulgaria Sofia BEVER-DRIVE GmbH Bogdanovetz Str.1 BG-1606 Sofia Cameroon Douala Electro-s Rue Drouot Akwa B.P Douala Tel Fax bever@bever.bg Tel Fax electrojemba@yahoo.fr Canada Toronto Vancouver SEW-EURODRIVE CO. OF CANADA LTD. 210 Walker Drive Bramalea, ON L6T 3W1 SEW-EURODRIVE CO. OF CANADA LTD. Tilbury Industrial Park 7188 Honeyman Street Delta, BC V4G 1G1 Montreal SEW-EURODRIVE CO. OF CANADA LTD Rue Leger Lasalle, PQ H8N 2V9 Additional addresses for service in Canada provided on request! Tel Fax l.watson@sew-eurodrive.ca Tel Fax b.wake@sew-eurodrive.ca Tel Fax a.peluso@sew-eurodrive.ca Chile Santiago de Chile SEW-EURODRIVE CHILE LTDA. Las Encinas 1295 Parque Industrial Valle Grande LAMPA RCH-Santiago de Chile P.O. Box Casilla 23 Correo Quilicura - Santiago - Chile Tel Fax ventas@sew-eurodrive.cl China Production Tianjin SEW-EURODRIVE (Tianjin) Co., Ltd. No. 46, 7th Avenue, TEDA Tianjin Tel Fax info@sew-eurodrive.cn Suzhou SEW-EURODRIVE (Suzhou) Co., Ltd. 333, Suhong Middle Road Suzhou Industrial Park Jiangsu Province, Tel Fax suzhou@sew-eurodrive.cn Guangzhou SEW-EURODRIVE (Guangzhou) Co., Ltd. No. 9, JunDa Road East Section of GETDD Guangzhou Tel Fax guangzhou@sew-eurodrive.cn Shenyang SEW-EURODRIVE (Shenyang) Co., Ltd. 10A-2, 6th Road Shenyang Economic Technological Development Area Shenyang, Tel Fax shenyang@sew-eurodrive.cn Wuhan SEW-EURODRIVE (Wuhan) Co., Ltd. 10A-2, 6th Road No. 59, the 4th Quanli Road, WEDA Wuhan Tel Fax wuhan@sew-eurodrive.cn Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 61

62 8 Address List China Xi'An SEW-EURODRIVE (Xi'An) Co., Ltd. No. 12 Jinye 2nd Road Xi'An High-Technology Industrial Development Zone Xi'An Additional addresses for service in China provided on request! Tel Fax Colombia Bogotá SEW-EURODRIVE COLOMBIA LTDA. Calle 22 No Bodega 6, Manzana B Santafé de Bogotá Tel Fax sewcol@sew-eurodrive.com.co Croatia Zagreb KOMPEKS d. o. o. Zeleni dol 10 HR Zagreb Tel Fax kompeks@inet.hr Czech Republic Prague SEW-EURODRIVE CZ S.R.O. Business Centrum Praha Lužná 591 CZ Praha 6 - Vokovice Tel Fax sew@sew-eurodrive.cz Denmark Copenhagen SEW-EURODRIVEA/S Geminivej DK-2670 Greve Tel Fax sew@sew-eurodrive.dk Egypt Cairo Copam Egypt for Engineering & Agencies 33 EI Hegaz ST, Heliopolis, Cairo Tel Fax copam@datum.com.eg Estonia Tallin ALAS-KUUL AS Reti tee 4 EE Peetri küla, Rae vald, Harjumaa Tel Fax veiko.soots@alas-kuul.ee Finland Lahti SEW-EURODRIVE OY Vesimäentie 4 FIN Hollola 2 Tel Fax sew@sew.fi Production Karkkila SEW Industrial Gears Oy Valurinkatu 6, PL 8 FI Karkkila, Karkkila Tel Fax sew@sew.fi Gabon Libreville ESG Electro s Gabun Feu Rouge Lalala 1889 Libreville Gabun Tel Fax esg_services@yahoo.fr 62 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

63 Address List 8 Great Britain Normanton SEW-EURODRIVE Ltd. Beckbridge Industrial Estate Normanton West Yorkshire WF6 1QR Tel Fax info@sew-eurodrive.co.uk Drive Hotline / 24 Hour Tel Greece Athens Christ. Boznos & Son S.A. 12, K. Mavromichali Street P.O. Box GR Piraeus Tel Fax info@boznos.gr Hong Kong Hong Kong SEW-EURODRIVE LTD. Unit No , 8th Floor Hong Leong Industrial Complex No. 4, Wang Kwong Road Kowloon, Hong Kong Tel Fax contact@sew-eurodrive.hk Hungary Budapest SEW-EURODRIVE Kft. H-1037 Budapest Kunigunda u. 18 Tel Fax office@sew-eurodrive.hu India Registered Office Vadodara SEW-EURODRIVE India Private Limited Plot No. 4, GIDC POR Ramangamdi Vadodara Gujarat Tel , Fax , salesvadodara@seweurodriveindia.com Chennai SEW-EURODRIVE India Private Limited Plot No. K3/1, Sipcot Industrial Park Phase II Mambakkam Village Sriperumbudur Kancheepuram Dist, Tamil Nadu Tel Fax saleschennai@seweurodriveindia.com Vadodara SEW-EURODRIVE India Private Limited Unit No. 301, Savorite Bldg, Plot No. 143, Vinayak Society, off old Padra Road, Vadodara Gujarat Tel Fax salesvadodara@seweurodriveindia.com Ireland Dublin Alperton Engineering Ltd. 48 Moyle Road Dublin Industrial Estate Glasnevin, Dublin 11 Tel Fax info@alperton.ie Israel Tel-Aviv Liraz Handasa Ltd. Ahofer Str 34B / Holon Tel Fax office@liraz-handasa.co.il Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 63

64 8 Address List Italy Solaro SEW-EURODRIVE di R. Blickle & Co.s.a.s. Via Bernini,14 I Solaro (Milano) Tel Fax Ivory Coast Abidjan SICA Société industrielle & commerciale pour l'afrique 165, Boulevard de Marseille 26 BP 1115 Abidjan 26 Tel Fax Japan Iwata SEW-EURODRIVE JAPAN CO., LTD 250-1, Shimoman-no, Iwata Shizuoka Tel Fax Kazakhstan Almaty ТОО "СЕВ-ЕВРОДРАЙВ" пр.райымбека, г. Алматы Республика Казахстан Latvia Riga SIA Alas-Kuul Katlakalna 11C LV-1073 Riga Lebanon Beirut Gabriel Acar & Fils sarl B. P Bourj Hammoud, Beirut Jordan Kuwait Saudi Arabia Syria Beirut Middle East Drives S.A.L. (offshore) Sin El Fil. B. P Beirut Lithuania Alytus UAB Irseva Statybininku 106C LT Alytus Тел. +7 (727) Факс +7 (727) Tel Fax info@alas-kuul.com Tel Fax ssacar@inco.com.lb Tel Fax info@medrives.com Tel Fax info@irseva.lt Luxembourg Brussels SEW Caron-Vector Research park Haasrode Evenementenlaan 7 BE-3001 Leuven Tel Fax info@sew-eurodrive.be Malaysia Johore SEW-EURODRIVE SDN BHD No. 95, Jalan Seroja 39, Taman Johor Jaya Johor Bahru, Johor West Malaysia Tel Fax sales@sew-eurodrive.com.my 64 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

65 Address List 8 Mexico Quéretaro SEW-EURODRIVE MEXICO SA DE CV SEM M93 Tequisquiapan No. 102 Parque Industrial Quéretaro C.P Quéretaro, México Tel Fax scmexico@seweurodrive.com.mx Morocco Casablanca Afit Route D El Jadida KM 14 RP8 Province de Nouaceur Commune Rurale de Bouskoura MA Casablanca Tel Fax fatima.haquiq@premium.net.ma Netherlands Rotterdam VECTOR Aandrijftechniek B.V. Industrieweg 175 NL-3044 AS Rotterdam Postbus NL-3004 AB Rotterdam Tel Fax info@sew-eurodrive.nl New Zealand Auckland SEW-EURODRIVE NEW ZEALAND LTD. P.O. Box Greenmount drive East Tamaki Auckland Tel Fax sales@sew-eurodrive.co.nz Christchurch SEW-EURODRIVE NEW ZEALAND LTD. 10 Settlers Crescent, Ferrymead Christchurch Tel Fax sales@sew-eurodrive.co.nz Norway Moss SEW-EURODRIVE A/S Solgaard skog 71 N-1599 Moss Tel Fax sew@sew-eurodrive.no Pakistan Karachi Industrial Power Drives Al-Fatah Chamber A/3, 1st Floor Central Commercial Area, Sultan Ahmed Shah Road, Block 7/8, Karachi Tel Fax seweurodrive@cyber.net.pk Peru Lima SEW DEL PERU MOTORES REDUCTORES S.A.C. Los Calderos, Urbanizacion Industrial Vulcano, ATE, Lima Tel Fax sewperu@sew-eurodrive.com.pe Poland Lodz SEW-EURODRIVE Polska Sp.z.o.o. ul. Techniczna 5 PL Łódź Tel Fax sew@sew-eurodrive.pl 24 Hour Tel ( SEW SEW) serwis@sew-eurodrive.pl Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 65

66 8 Address List Portugal Coimbra SEW-EURODRIVE, LDA. Apartado 15 P Mealhada Tel Fax Romania Bucharest Sialco Trading SRL str. Madrid nr Bucuresti Tel Fax Russia St. Petersburg ZAO SEW-EURODRIVE P.O. Box St. Petersburg Russia Tel Fax Senegal Dakar SENEMECA Mécanique Générale Km 8, Route de Rufisque B.P. 3251, Dakar Serbia Beograd DIPAR d.o.o. Ustanicka 128a PC Košum, IV floor SCG Beograd Tel Fax Tel / Fax office@dipar.rs Singapore Singapore SEW-EURODRIVE PTE. LTD. No 9, Tuas Drive 2 Jurong Industrial Estate Singapore Tel Fax sewsingapore@sew-eurodrive.com Slovakia Bratislava SEW-Eurodrive SK s.r.o. Rybničná 40 SK Bratislava Žilina Banská Bystrica Košice SEW-Eurodrive SK s.r.o. Industry Park - PChZ ulica M.R.Štefánika 71 SK Žilina SEW-Eurodrive SK s.r.o. Rudlovská cesta 85 SK Banská Bystrica SEW-Eurodrive SK s.r.o. Slovenská ulica 26 SK Košice Tel Fax sew@sew-eurodrive.sk Tel Fax sew@sew-eurodrive.sk Tel Fax sew@sew-eurodrive.sk Tel Fax sew@sew-eurodrive.sk Slovenia Celje Pakman - Pogonska Tehnika d.o.o. UI. XIV. divizije 14 SLO Celje Tel Fax pakman@siol.net 66 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

67 Address List 8 South Africa Johannesburg SEW-EURODRIVE (PROPRIETARY) LIMITED Eurodrive House Cnr. Adcock Ingram and Aerodrome Roads Aeroton Ext. 2 Johannesburg 2013 P.O.Box Bertsham 2013 Tel Fax info@sew.co.za Cape Town SEW-EURODRIVE (PROPRIETARY) LIMITED Rainbow Park Cnr. Racecourse & Omuramba Road Montague Gardens Cape Town P.O.Box Chempet 7442 Cape Town Tel Fax Telex cfoster@sew.co.za Durban SEW-EURODRIVE (PROPRIETARY) LIMITED 2 Monaco Place Pinetown Durban P.O. Box 10433, Ashwood 3605 Tel Fax cdejager@sew.co.za Nelspruit SEW-EURODRIVE (PTY) LTD. 7 Christie Crescent Vintonia P.O.Box 1942 Nelspruit 1200 Tel Fax robermeyer@sew.co.za South Korea Ansan-City SEW-EURODRIVE KOREA CO., LTD. B 601-4, Banweol Industrial Estate , Shingil-Dong Ansan Tel Fax master.korea@sew-eurodrive.com Busan SEW-EURODRIVE KOREA Co., Ltd. No , Songjeong - dong Gangseo-ku Busan Tel Fax master@sew-korea.co.kr Spain Bilbao SEW-EURODRIVE ESPAÑA, S.L. Parque Tecnológico, Edificio, 302 E Zamudio (Vizcaya) Tel Fax sew.spain@sew-eurodrive.es Sweden Jönköping SEW-EURODRIVE AB Gnejsvägen 6-8 S Jönköping Box 3100 S Jönköping Tel Fax jonkoping@sew.se Switzerland Basel Alfred lmhof A.G. Jurastrasse 10 CH-4142 Münchenstein bei Basel Tel Fax info@imhof-sew.ch Thailand Chonburi SEW-EURODRIVE (Thailand) Ltd. 700/456, Moo.7, Donhuaroh Muang Chonburi Tel Fax sewthailand@sew-eurodrive.com Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 67

68 8 Address List Tunisia Tunis T. M.S. Technic Marketing Zone Industrielle Mghira 2 Lot No Fouchana Tel Fax tms@tms.com.tn Turkey Istanbul SEW-EURODRIVE Hareket Sistemleri San. ve Tic. Ltd. Sti. Bagdat Cad. Koruma Cikmazi No. 3 TR Maltepe ISTANBUL Tel / Fax sew@sew-eurodrive.com.tr Ukraine Dnepropetrovsk SEW-EURODRIVE Str. Rabochaja 23-B, Office Dnepropetrovsk Tel Fax sew@sew-eurodrive.ua United Arab Emirates Sharjah Copam Middle East (FZC) Sharjah Airport International Free Zone P.O. Box Sharjah Tel Fax copam_me@eim.ae USA Production Southeast Region Northeast Region Midwest Region Southwest Region SEW-EURODRIVE INC Old Spartanburg Highway P.O. Box 518 Lyman, S.C SEW-EURODRIVE INC. Pureland Ind. Complex 2107 High Hill Road, P.O. Box 481 Bridgeport, New Jersey SEW-EURODRIVE INC West Main Street Troy, Ohio SEW-EURODRIVE INC Platinum Way Dallas, Texas Western Region SEW-EURODRIVE INC San Antonio St. Hayward, CA Additional addresses for service in the USA provided on request! Tel Fax Fax Manufacturing Fax Fax Confidential/HR cslyman@seweurodrive.com Tel Fax csbridgeport@seweurodrive.com Tel Fax cstroy@seweurodrive.com Tel Fax csdallas@seweurodrive.com Tel Fax cshayward@seweurodrive.com Venezuela Valencia SEW-EURODRIVE Venezuela S.A. Av. Norte Sur No. 3, Galpon Zona Industrial Municipal Norte Valencia, Estado Carabobo Tel Fax ventas@sew-eurodrive.com.ve sewfinanzas@cantv.net 68 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

69 Address List 8 Vietnam Ho Chi Minh City All sectors except for ports, mining and offshore: Nam Trung Co., Ltd 250 Binh Duong Avenue, Thu Dau Mot Town, Binh Duong Province HCM office: 91 Tran Minh Quyen Street District 10, Ho Chi Minh City Hanoi Ports, mining and offshore: DUC VIET INT LTD Industrial Trading and Engineering s A75/6B/12 Bach Dang Street, Ward 02, Tan Binh District, Ho Chi Minh City Nam Trung Co., Ltd R.205B Tung Duc Building 22 Lang ha Street Dong Da District, Hanoi City Tel Fax namtrungco@hcm.vnn.vn truongtantam@namtrung.com.vn khanh-nguyen@namtrung.com.vn Tel Fax totien@ducvietint.com Tel Fax namtrunghn@hn.vnn.vn Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 69

70 Index Index A Aluminum profile rail Disconnection Safe...10 Disposal...45 B Blanking plugs TCS compensation box...19 TVS connection distributor...20 C Cable bushing TIS...-A..-0 Dimension drawing...57 Cable gland...47, 48 Cable lug...47, 48 Cable outlet TLS supply cable...32 Cable type TLS line cable...29 Certifications...46 Clamp area...48 Clamping area...47 Connection Safety notes...10 TLS line cable to TCS10A...32 TLS line cable to TCS10B...33 TLS line cable to TVS10A...34, 36 TLS line cable to TVS10B...35 TLS supply cable to TVS10B...36 Copyright...6 CSA certifications...46 D Dimension drawing Cable bushing TIS...-A Shielding plate...58 TCS10A compensation box...49 TCS10B compensation box...49 TIS...-A..-0 cable bushing grommet...57 TIS...-F..-0 profile section...56 TIS...-H..-0 holding fixture...55 TIS...-P..-0 profile section...55, 56 TIS...-V..-0 installation plate...52 TIS...-X..-0 retaining plate...53, 54 TVS10A connection distributor...50 TVS10B connection distributor...50 E Earth connection TCS10B compensation box...39 TVS10B connection distributor...39 Electrical connection...10 Embedded safety notes...5 EN EN / EN Exclusion of liability...6 F Functional safety technology...9 G Grounding TCS10A compensation box...37 TVS10A connection distributor...37 I Installation...9 Aluminum profile rail...42 TIS...-F..-0 profile section...41 TIS...-P..-0 profile section...41 Universal installation...43 Installation components TIS Installation...40 Installation dimension Installation on aluminum profile rail...42 Universal installation...44 N Nameplate TCS compensation box...15 TVS connection distributor...15 Notes Designation in the documentation...5 O Operation Safety notes Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

71 Index P Prefabrication TLS line cable...28 TLS supply cable...32 Tools...28 Product names...6 R Rights to claim under limited warranty...6 S Safe disconnection...10 Safety functions...9 Safety notes Designation in the documentation...5 General...7 Preliminary information...7 Structure of the embedded safety notes...5 Structure of the section-related safety notes...5 Section-related safety notes Shielding plate Dimension drawing...58 Signal words in the safety notes...5 Startup Safety notes...11 Storage...9 Supply TLS Connection to TAS...47 Connection to TCS...47 T Target group...7 TCS compensatio box design...19 TCS compensation box blanking plugs...19 Dimension drawing...49 Function...19 Nameplate...15 scope of delivery...16 Type designation...12 TCS10A Compensation box Connection to TLS...32 TCS10A compensation box Earth connection...37 TCS10B compensation box Earth connection...39 TCS10BA Compensation box Connection to TLS...33 TIS installation components type designation...14 TIS...-A..-0 cable bushing design...27 function...27 scope of delivery...18 TIS...-A..-0 cable bushing frame certifications...46 TIS...-A..-0 cable bushing grommet Dimension drawing...57 TIS...-F..-0 profile section certifications...46 design...26 dimension drawing...56 function...26 Installation...41 scope of delivery...18 TIS...-H..-0 holding fixture certifications...46 design...24 dimension drawing...55 function...24 scope of delivery...17 TIS...-P..-0 profile section certifications...46 design...25 dimension drawing...55, 56 function...25 Installation...41 scope of delivery...18 TIS...-V..-0 installation plate design...22 Dimension drawing...52 function...22 scope of delivery...17 TIS...-X..-0 retaining plate design...23 Dimension drawing...53, 54 function...23 scope of delivery...17 Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS 71

72 Index TLS line cable Cable type...29 certifications...46 Connection to TAS...47 connection to TAS...48 Connection to TCS...47 Connection to TCS10A...32 Connection to TCS10B...33 connection to TVS...48 Connection to TVS10A...34, 36 Connection to TVS10B...35 design...21 electrical properties...47 function...21 mechanical properties...46 Prefabrication...28 scope of delivery...17 Soldering cable lugs...30 technical data...46 type designation...13 TLS supply cable cable outlet...32 certifications...46 connection to TAS...48 Connection to TVS10B...36 design...21 electrical properties...47 function...21 mechanical properties...46 prefabrication...32 scope of delivery...17 technical data...46 Tools Prefabrication...28 Trademarks...6 Transport...9 TVS connection distributor Blanking plugs...20 design...20 Dimension drawing...50 function...20 Nameplate...15 scope of delivery...16 Type designation...12 TVS10A Compensation box Connection to TLS...34 TVS10A compensation box Connection to TLS...36 TVS10A connection distributor Earth connection...37 TVS10B Compensation box Connection to TLS...35, 36 TVS10B connection distributor Earth connection...39 Type designation TCS compensation box...12 TIS installation components...14 TLS line cable...13 TVS connection distributor...12 U UL certifications...46 Universal installation Operating Instructions MOVITRANS Installation Material TCS, TVS, TLS, TIS

73

74

75

76 SEW-EURODRIVE Driving the world SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 D Bruchsal/Germany Phone Fax

3 Cleaning. 4 Technical data

3 Cleaning. 4 Technical data EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution

More information

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E. www.wampfler.com Page 1 of 27 Index Page 1 Basics...4 2 Basic understanding of an IPT -system...5 3 General rules regarding metal parts in close proximity...6 3.1 Envelope free of ferromagnetic material...6

More information

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130 Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control Operating Instructions for Netter Static Adjustable Frequency Control Series SRF July 2016 No.1451E Page 1/23 These operating instructions apply to Netter Static Adjustable Frequency Control NetterVibrotron

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16) Satellite multiswitch Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16) EMP-CENTAURI is a registered trademark Dear Customer, Thank you for buying the EMP-Centauri

More information

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16) Satellite multiswitch Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-AP-12 (13/12) P.160-CP-12 (13/12) P.160-AP-16 (13/16) P.160-CP-16 (13/16) EMP-CENTAURI is a registered trademark Dear

More information

NewScope-7A Operating Manual

NewScope-7A Operating Manual 2016 SIMMCONN Labs, LLC All rights reserved NewScope-7A Operating Manual Preliminary May 13, 2017 NewScope-7A Operating Manual 1 Introduction... 3 1.1 Kit compatibility... 3 2 Initial Inspection... 3 3

More information

Installation instructions Ex frames

Installation instructions Ex frames General information Installation and maintenance: For European member countries of GENELEC shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Dragonfly Quad. User Manual V1.4. Order code: EQLED101 Dragonfly Quad User Manual V1.4 Order code: EQLED101 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! USER MANUAL DE-1 Police-light CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! For your own safety, please read this user manual carefully before you

More information

Optical Distribution Box 300 Installation Guide. Version : R0.0

Optical Distribution Box 300 Installation Guide. Version : R0.0 Optical Distribution Box 300 Installation Guide Document No. : OD16-546-L-01 Version : R0.0 Date: 21-Mar-2018 IMPORTANT INSTRUCTIONS When using fiber optic equipment, basic precautions should always be

More information

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide In-Ceiling Electric Motorized Front Projection Screen Evanesce Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The

More information

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device 3 x cinch/s-video socket Order no. 33 1532 xx USB/3.5 mm audio socket Order no. 33 1539 xx VGA socket Order no. 33 1540 xx VGA socket with screw-in lift terminals Order no. 33 1541 xx High definition socket

More information

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723 User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723 Preface Read this user manual carefully before using this product. Pictures shown in this manual is

More information

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex. Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX 2562089B REV. B 110 Printed in U.S.A. MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

More information

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0109-001 PRODUCT REVISION: 1 PNP202 Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the PNP202 Interconnect Box is greatly appreciated. We are sure you will find it

More information

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians Radio receiver EXL 4-channel / up to 1000 memory locations Mounting and operating instructions for qualified electricians Please keep these instructions so that you have them available if you have any

More information

Keysight 16048G/H Test Leads

Keysight 16048G/H Test Leads Keysight 16048G/H Test Leads Operation and Service Manual Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is

More information

Installation Manual for New or Retrofit Installations

Installation Manual for New or Retrofit Installations Installation Manual for New or Retrofit Installations Release Date: 24-August-2015 c Able Applied Technologies LTD. READ THE ENTIRE MANUAL COMPLETELY AND CAREFULLY BEFORE STARTING BEFORE YOU BEGIN ASSEMBLY

More information

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN Deadbreak Apparatus Connectors MN650017EN Effective January 2016 Supersedes S600-46-2 July 2014 COOPER POWER SERIES 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions DISCLAIMER

More information

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS CERN INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 Edms 335813 TIS IS 48 Edited by: TIS/GS Publication Date: June 2001 Original: English FIRE PREVENTION FOR CABLES, CABLE

More information

S Regulators. Supplement 1. Contents. Control Replacement Assembly Installation Instructions Supplement

S Regulators. Supplement 1. Contents. Control Replacement Assembly Installation Instructions Supplement Regulators Control Replacement Assembly Installation Instructions Supplement Service Information S225-40-1 Supplement 1 Figure 1. CL-6A Control Replacement Assembly. Contents Safety Information... 2 Product

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED 0 INTRODUCTION Video Lift is an electro-mechanical device which, once installed in the ceiling, allows vertical movement (ceiling floor ceiling) for loads of up to 19 Kg and with maximum runs of 1 metre

More information

Product information. Front-door station series with video for surface-mount

Product information. Front-door station series with video for surface-mount Product information Front-door station series with video for surface-mount series VPES series VPDS 2 05/2006 Table of contents Scope of delivery...3 Safety notices...3 General notes on the cabling in TCS

More information

LED Thunder S-150 Code 1097

LED Thunder S-150 Code 1097 LED Thunder S-150 Code 1097 User Manual 1 1 SAFETY INSTRUCTIONS This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely

More information

Register your product and get support at www.philips.com/welcome SDV8625T/27 User manual Contents 1 Important 4 Safety 4 For indoor use 4 For outdoor use 4 Notice for USA 4 Notice for Canada 5 Recycling

More information

MANUAL ENGLISH Core Club Ordercode: D2314

MANUAL ENGLISH Core Club Ordercode: D2314 MANUAL ENGLISH Core Club Ordercode: Highlite International B.V. Vestastraat 2 6468 EX Kerkrade the Netherlands Table of contents Warning... 2 Unpacking Instructions... 2 Safety Instructions... 2 Operating

More information

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR 3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR Instructions July 2010 78-8135-0094-5-K 3 1.0 General 1.1 3M Fiber Optic Splice Closure 2178-XSB The

More information

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2179-CD Series Fiber Optic Splice Closure. Installation Instructions 2179-CD Series Fiber Optic Splice Closure Installation Instructions 1.0 Product Introduction The new 3M TM 2179-CD Series Fiber Optic Splice Closure can be used in buried, underground, aerial, and pedestal

More information

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR 3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR Instructions July 2010 3 1.0 Contents 1.0 General...3 2.0 Kit Contents...3 3.0 Cable Preparation...4 4.0

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

Galaxias. Flex LED display. User Manual

Galaxias. Flex LED display. User Manual Galaxias Flex LED display User Manual Conterts Specifications 2 Dimension 3 Attentions 4 Introduction 5 Transportation 6 Installation 7 Maintenance 10 Troubleshooting 11 01 Specifications on Galaxias Series

More information

Operation and Maintenance Guide Electric Needle Scalers

Operation and Maintenance Guide Electric Needle Scalers Operation and Maintenance Guide Electric Needle Scalers Models Covered Model Number ENS100V ENS200V Electric Needle Scaler, 110V-1ph Electric Needle Scaler, 220V-1ph Description IMPA Number 59 12 01 59

More information

3M Distribution Box (DDB)

3M Distribution Box (DDB) 3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure

More information

Spectra Batten (Order code: LEDJ95)

Spectra Batten (Order code: LEDJ95) www.prolight.co.uk Spectra Batten (Order code: LEDJ95) Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

Install Guide Incredible Technologies, Inc. All Rights Reserved

Install Guide Incredible Technologies, Inc. All Rights Reserved Install Guide 2015 Incredible Technologies, Inc. All Rights Reserved Preface Using this Guide The following icons are used to highlight specific areas of interest and to indicate when extreme caution is

More information

DS1 Cross-Aisle Panel

DS1 Cross-Aisle Panel DS1 Cross-Aisle Panel Model 005-0005-0100 Installation Guide 1.1 Overview 1.1.1 Inspection Compare the contents of the DS1 Cross-Aisle Panel shipping container with the packing list. Call Telect if anything

More information

VGAD-12 ORDERCODE

VGAD-12 ORDERCODE VGAD-12 ORDERCODE 101220 Congratulations! You have bought a great, innovative product from DMT. The DMT Media Spinner brings excitement to any venue. Whether you want simple plug-&-play action or a sophisticated

More information

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2 User Manual PS-684 All Rights Reserved Version: UHBT70P_2016V1.2 Preface Read this user manual carefully before using this product. Pictures shown in this manual is for reference only, different model

More information

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL www.prolight.co.uk TRANSCENSION 6-CHANNEL PACK (order code: BOTE40) USER MANUAL SAFETY WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this

More information

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR Instructions September 2017 78-8130-5055-2-M 2 September 2017 78-8130-5055-2-M 1.0 Kit Contents 2.0 General...

More information

Vibratory Deck Sieves 15 in. (380 mm)

Vibratory Deck Sieves 15 in. (380 mm) Instruction Sheet P/N 1604433-01 Vibratory Deck Sieves 15 in. (380 mm) Introduction This instruction sheet covers the vibratory deck sieves listed in the following tables. 15-Inch Deck Sieves with 2.5

More information

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC CHECK LINE BY ELECTROMATIC Stationary Stroboscope Model LS-36-LED Operating Manual Table of Contents 1.0 Introduction... 02 1.1 Unpacking 1.2 Optional Accessories 2.0 Safety Information... 3 3.0 Controls...

More information

Industrial Monitor Update Kit

Industrial Monitor Update Kit Industrial Monitor Update Kit (Bulletin Number 6157) Installation Instructions 2 Table of Contents Table of Contents Industrial Monitor Update Kit... 3 Overview... 3 Part 1 - Initial Preparation... 5 Part

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

16 Amp Electronic 24 Hour/7 Day Time Controller

16 Amp Electronic 24 Hour/7 Day Time Controller 16 Amp Electronic 24 Hour/7 Day Time Controller Model: ELU56 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

DLP200M 2 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless

More information

Gear Pump Units For single-line centralized lubrication systems

Gear Pump Units For single-line centralized lubrication systems 1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,

More information

Heating thermostat Series AMHs B Operating Instructions 11.06/

Heating thermostat Series AMHs B Operating Instructions 11.06/ Heating thermostat Series AMHs-1-80 B 60.3045.0 Operating Instructions 11.06/ 00367556 Typographical conventions Warning signs The signs for Danger and Warning are used in this manual under the following

More information

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010 Operating instructions Retro-reflective sensor OJ50xx laser 70481 / 00 05 / 010 Contents 1 Preliminary note3 1.1 Symbols used 3 Safety instructions 3 4 Installation 4 4.1 Installation of the supplied mounting

More information

Fusion 120 Zoom. User Manual. Order code: EQLED068

Fusion 120 Zoom. User Manual. Order code: EQLED068 Fusion 120 Zoom User Manual Order code: EQLED068 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

Panel-Mounted Thermostat

Panel-Mounted Thermostat Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief

More information

Operation Manual VMS 3.0 Video System

Operation Manual VMS 3.0 Video System Operation Manual VMS 3.0 Video System for the AlterG Anti-Gravity Treadmill 1 This manual covers operation procedures for the following AlterG products: AlterG Video System model VMS 3.0 NOTE: The following

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our

More information

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version Spectra Flood Q40 Exterior Fixture User Manual Order code: LEDJ284-40 Version LEDJ284N - 15 Version Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

Installation Guide VL-MV10. Model No.

Installation Guide VL-MV10. Model No. Installation Guide Model Name Model No. Main Monitor Station VL-MV0 R Main monitor station is described as "main monitor" in this guide. R In this guide, the suffix of each model number (e.g., the "EX"

More information

Filters for Power Lines (Low Leakage Current)

Filters for Power Lines (Low Leakage Current) Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures

More information

Installation Manual Original Instructions - IW4001

Installation Manual Original Instructions - IW4001 Installation Manual Original Instructions - IW4001 Installation Manual 1 General Operator and Supervisor Information Signal Word Definition Signal Word Panel Table of Contents Operator and Supervisor Information

More information

TRF STEP-DOWN TRANSFORMER USER MANUAL

TRF STEP-DOWN TRANSFORMER USER MANUAL TRF STEP-DOWN TRANSFORMER USER MANUA www.ventilation-system.com 2013 ! WARNING The present operation manual consisting of the technical details, operating instructions and technical specification applies

More information

DSP 18 Sub active subwoofer. user manual

DSP 18 Sub active subwoofer. user manual DSP 18 Sub active subwoofer user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 05.11.2018,

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Operating instructions Through-beam sensor. OJ51xx laser / / 2010 Operating instructions Through-beam sensor OJ5xx laser 70480 / 00 05 / 200 Contents Preliminary note. Symbols used 2 Safety instructions Functions and features 4 4 Installation 4 5 Electrical connection5

More information

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Website:   Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide Website: www.flexispot.com Tel: -855-4-808 ADDRESS: 6475 Las Positas Rd. Livermore, CA 9455 Item No. E5B/E5S Installation Guide Specifications Step Column 3 Max. Weight Capacity 0 Ibs (00 kg) Speed 38mm/s

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Power Injector 1520 Series

Power Injector 1520 Series Power Injector 1520 Series Technical Specifications Input voltage 100 to 240 VAC Output voltage 56.0 VDC Voltage range tolerance 54 VDC to 57 VDC Maximum current 1.43 A No load current 15 ma 56VDC@0.71A

More information

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc.. At first, thank you for purchasing QUADRO 24. For the sake of safety and regular operation of this projector, please read this manual carefully before using and operating it, lest incur any personal injury

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL SERIAL NUMBER CUSTOMER: SALES REP.: CONTENTS Mixer Installation / Assembly / Dimension Drawings Safety... 1 Customer Service Contact... 1 Initial Inspection... 2 Installation...2

More information

Installation Manual SaVi Note Underwater LED Light

Installation Manual SaVi Note Underwater LED Light Installation Manual SaVi Note Underwater LED Light Model Numbers SAVI-NOTE7, SAVI-NOTE0 Table of Contents Safety Precautions...2 SaVi Note Install Instructions...3- M Instructions...- Warnings READ AND

More information

LED Spot 300W. Please read this user manual before your operation

LED Spot 300W. Please read this user manual before your operation LED Spot 300W Please read this user manual before your operation 1. Introduction 2. General Guideline 3. Safety Instructions 4. Cleaning and Maintenance 5. Technical Parameters 6. DMX Channels 7. Remark

More information

4 Wiring Brochure Wiring and installation of specific control

4 Wiring Brochure Wiring and installation of specific control - Wiring Brochure tekmarnet 4 User Switch 480 W 480 09/09 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500 Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B

More information

Installation instructions Cable transit device Roxtec RS ES Ex

Installation instructions Cable transit device Roxtec RS ES Ex General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure Box Fan R87B CSM_R87B_DS_E_4_2 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.andinst.com Instrument Model Number Instrument Serial Number MODEL RSP SANITARY

More information

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L Commander 384 w w w. p r o l i g h t. c o. u k U S E R M A N U A L 1, Before you begin 1.1: Safety warnings...2 3 1.2: What is included...4 1.3: Unpacking instructions...4 2, Introduction 2.1: Features...4

More information

Monochrome Video Monitors

Monochrome Video Monitors Instructions for Use Monochrome Video Monitors En F D E NL I LTC 2009 LTC 2012 LTC 2017 Philips Communication & Security Systems GB F D E NL I Instructions for Use...1.1 Mode d emploi...2.1 Bedienungsanleitung...3.1

More information

EXT-HBT70-SET_2016V1.2

EXT-HBT70-SET_2016V1.2 USER MANUAL EXT-HBT70-SET HDBaseT Extender Set 70m All Rights Reserved Version: EXT-HBT70-SET_2016V1.2 Preface Read this user manual carefully before using this product. Pictures shown in this manual is

More information

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1 User Manual TP70L HDBaseT Extender All Rights Reserved Version: TP70L2016V1.1 Preface Read this user manual carefully before using this product. Pictures shown in this manual is for reference only, different

More information

Figure 1: Device components

Figure 1: Device components Order No. : 2860 10 Order No. : 2830 10 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe

More information

Achat 115 Sub A active subwoofer. user manual

Achat 115 Sub A active subwoofer. user manual Achat 115 Sub A active subwoofer user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Deutschland Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c User Guide Single-Link DVI Active Cable Extender DVI-7171c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

Trusted TMR I/O SmartSlot Slot Cables

Trusted TMR I/O SmartSlot Slot Cables PD-TC500 Trusted Trusted TMR I/O SmartSlot Slot Cables Product Overview This document provides detailed information for the types of Trusted input/output (I/O) Cables available within the SmartSlot group.

More information

HCS - HES Cabling Systems

HCS - HES Cabling Systems HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the

More information

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces Automatic s 2004 Automatic. All rights reserved. pdf 1.0 3-18-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable Plugs...................

More information

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL LED Beam Moving Head TWIST-150LED Order No. 38.7970 INSTRUCTION MANUAL MONACOR INTERNATIONAL GmbH & Co. KG Zum Falsch 36 28307 Bremen Germany www.monacor.com 01.30.11.2016 ELECTRONICS FOR SPECIALISTS ELECTRONICS

More information

Trusted 40 Channel 120 Vac Digital Input FTA

Trusted 40 Channel 120 Vac Digital Input FTA PD-T8824 Trusted Trusted 40 Channel 120 Vac Digital Input FTA Product Overview The Trusted 40 Channel 120 Vac Digital Input Field Termination Assembly (FTA) T8824 is designed to act as the main interface

More information

NOTE: The illustrations in this manual may not look the same as your product, but your unit will function in the same way.

NOTE: The illustrations in this manual may not look the same as your product, but your unit will function in the same way. 1 OVERVIEW The Ethernet Black Box Sonar allows you to connect select transducers and accessories to your SOLIX, ONIX, or ION control head. Connect up to two Black Box Sonars on your Ethernet network. Example

More information

Colour Explosion Proof Video Camera USER MANUAL VID-C

Colour Explosion Proof Video Camera USER MANUAL VID-C Colour Explosion Proof Video Camera USER MANUAL VID-C Part Number: MAN-0036-00 Rev 4 Copyright 2002 Net Safety Monitoring Inc. Printed in Canada This manual is provided for informational purposes only.

More information

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you

More information