1 Essentials of Digital Imaging Module 3 Transcript 2016 ASRT. All rights reserved.

2 Essentials of Digital Imaging Module 3 Display 1. ASRT Animation 2. Welcome Welcome to the Essentials of Digital Imaging Module 3 Display. 3. License Agreement 4. Objectives After completing this module, you will be able to: Differentiate between a cathode ray tube and a liquid crystal display monitor. Define the characteristics of a monitor that affect image display. Explain the features of a modality workstation monitor. Describe how a modality workstation functions. 5. CRT Monitor Animation CRT technology has been around much longer than LCD equipment, and is still used to provide excellent images. An electron gun, or cathode, creates images by beaming electrons towards an anode. Instead of striking the anode, however, these electrons are deflected toward the monitor s fluorescent screen to construct the image. There are 2 types of image acquisition: interlaced and progressive. There is an obvious difference between how the image is produced based on how they acquired data is transferred to the monitor display. The progressive process fills each line from top to bottom, whereas interlaced acquisition fills every other line top to bottom and then returns to the top to fill in the missing lines of data. 6. LCD and LED-LCD Monitors The LCD and LED-LCD monitors are constructed of 2 sections of polarized glass with liquid crystals sandwiched between the glass layers. The crystals allow different light waveforms to pass through the monitor and be viewed on the screen, diffusing the light as appropriate. The difference between the two monitor types is the light source for the liquid crystals. A traditional LCD monitor uses a cold cathode fluorescent light source and the LED-LCD uses a light emitting diode as the light source. 7. Display Characteristics There are several factors that affect image display. Although technologists can t modify the image display characteristics of a digital imaging system, it s important to understand the role a display monitor has in viewing digital images. The monitors used with acquisition workstations can be cathode ray tube (CRT) or liquid crystal display (LCD) types. Their dimensional shape is one way to distinguish between them. A CRT monitor is much deeper from the screen to the back of the device. An LCD monitor is thinner from front to back. In general, a CRT monitor provides more luminance, especially in the center of the image. They have lower measurable black levels and better color reproduction. The phosphor granularity of a CRT adds to the spatial noise recognition of the image, the viewable area is actually smaller than the stated size, and the aspect ratio is 4:3. Not only are CRT monitors more responsive on redraw they are more durable than LCD monitors. On the other hand, an LCD monitor produces less screen glare, or veiling glare, offers better spatial resolution, and is easier to move and reposition. The LCD monitor consumes less energy and provides a larger viewing area that is closer to the described size. Additionally, it leaves a smaller footprint than the CRT counterpart while providing a wider screen aspect ratio of 16:9. A limitation of the LCD is that it can only display the designed resolution. There are several characteristics of the monitor that can affect its display which include spatial resolution, vertical and horizontal resolution, the size of the display, aspect and matrix ratio, pixel size and pixel pitch.

3 8. CRT and LCD Resolution For a CRT monitor, spatial resolution is determined by the bandwidth, line spacing, and electron beam size. The vertical resolution depends on line spacing and spot size which is the ability of the tube to focus the electron beam. Horizontal resolution depends on bandwidth and spot size. An LCD monitor's resolution is determined by the pixel size and pitch. The smaller the pixel size the greater the spatial resolution. The pixel pitch is the distance between the cells of the same color. The vertical and horizontal resolution is determined by the pixel pitch in that given direction. 9. Display Size The size of the display screen also plays a role in resolution. The screen is measured diagonally from corner to corner. For a CRT monitor, the measurement is taken from the outside edges of the display casing. For an LCD monitor, the screen is measured from the inside of the beveled edge. There are several display characteristics, uses, and sizes for image viewing monitors such as XGA, an extended graphics array, up through WUXGA, a wide ultra XGA display. Each display type has its own unique resolution. These resolution values are similar to a laptop computer or your home PC, with resolutions such as 1024 x 768 or 1600 x These values represent the relationship of pixels on a vertical and horizontal axis across the monitor. An important consideration is the difference in resolution between the image acquisition work station and the diagnostic workstation used by the radiologist. The increased resolution of the diagnostic workstation can display suboptimal characteristics that are not apparent on the acquisition workstation. For example, a common issue is lost spatial resolution from motion seen on the diagnostic workstation. 10. Aspect Ratio Aspect ratio is another important display characteristic. Aspect ratio refers to the proportional relationship of the width and height of the display screen. Most CRT monitors have an aspect ratio of 4:3, whereas LCD monitors have an aspect ratio of 16:9 when viewed in a landscape format. 11. Matrix Ratio Matrix size also affects how an image appears. The larger the matrix, the more pixels on the display monitors, which results in smaller pixels and greater resolution. A 1 x 1 matrix doesn't really demonstrate what is contained in the image. The 100 x 100 display matrix provides a better image of the letter R in terms of spatial resolution compared with the smaller matrix sizes. 12. Pixel Size and Pixel Pitch Pixel size and pixel pitch values vary depending on the display monitor being used. The number of pixels is an important display characteristic. As the number of pixels per square centimeter increases, the monitor is able to display radiographs in a higher-resolution. Pixel pitch, also known as dot pitch, determines the sharpness of an image. In a CRT monitor, the pitch is the distance between phosphors. Gaps between pixels represent dead space meaning no image information can be displayed in that area. In an LCD monitor, the pitch measures from the center of 1 pixel to the center of an adjacent pixel and includes any gaps between them. The closer the pixels are together, the sharper the image because there are more pixels in the area. 13. Knowledge Check 14. Knowledge Check 15. Gray Scale To accurately display the gray scale in a radiograph, the display monitor needs to be able to demonstrate at least 256 shades of gray which is equivalent to 8 bits. In addition to the minimum gray-scale display, the American College of Radiology, or ACR, has determined the minimum requirement for spatial

4 resolution on diagnostic monitors must be 2.5 line pairs per millimeter when viewing a 14 x 17-inch, or 35.6 x 43.2 cm, image. 16. Display Noise Display noise, also referred to as monitor noise, is not the sound that you hear but rather what is visible on a finished radiograph. Monitors have 2 types of display noise. Spatial noise is caused by phosphor granularity. This type of image noise is the result of random luminance variations from construction characteristics and electrical signal variability inherent in LCD monitors. Temporal noise occurs when the electron beam intensity fluctuates as the beam scans back and forth across the back of the phosphor in the monitor. 17. Contrast Resolution The contrast resolution of a monitor is the difference between the maximum and minimum luminance of the display. Color depth determines the colors that can be displayed and depends on the graphics adapter and color capabilities of the monitor. Color bit depth refers to the number of bits used to create the color of a single pixel. 18. Maximal Luminance Maximal luminance, when referring to a video display, refers to monitor brightness. Current ACR standards specify that gray-scale monitors used for interpreting radiographs provide a minimum of 171 candela per square meter. The minimum level of luminance is called the black level, and CRTs have a measurably lower black level than LCD displays. Analog display brightness differs significantly compared with digital image display brightness. This is one reason that viewing angle and ambient lighting surrounding a workstation has such a tremendous effect on a technologist's ability to evaluate a digital image. Analog images on view boxes are much brighter. A mammography view box has a luminance between 3,000 and 7,500 cd/m2 where a standard view box has a luminance between 1,500 and 3,500 cd/m2. An LCD gray-scale monitor at a technologist s workstation has a luminance of 120 to 1000 cd/m2. If the monitor is a CRT then the luminance is 120 to 450 cd/m2. As a comparison, a standard PC color monitor displays at a luminance of 65 to 130 cd/m Refresh Rate The refresh rate of CRT monitors refers to the number of times an image is drawn on the screen each second. Refresh rates range from 60 to 120 images per second. Large CRT monitors flicker more visibly. Refresh rates vary. The refresh rate for a 1280 x 1024 matrix might be 85 hertz, or 85 cycles per second, whereas a 1600 x 1200 matrix has a refresh rate of 75 Hz, or 75 cycles per second. 20. Persistence Persistence is the delayed light emission from the phosphor after a CRT screen refreshes. Persistence helps when viewing static images, but it produces image lag in a cine-type display. Persistence with LCD based monitors is the result of the liquid crystals staying in one position following the termination of the applied electrical signal. In the case of LCD based monitors, image persistence is also known as image retention. 21. Technologist Workstation The technologist workstation has modality specific software that enables the workstation to be multifunctional. Technologists often can choose the patient name and exam from a modality work list, select the type of examination performed and the processing parameters for the image data, and determine how to display the resulting image. Technologist workstation monitors are used in bright, or well lit, areas. Monitoring luminance, or the brightness of a monitor display, is an important consideration when evaluating image quality. The monitor must allow a technologist to discern motion and to ensure anatomy is demonstrated properly. The ability of the monitor to display contrast directly affects the visibility of structures in an image. The display monitor is only as functional as its video card.

5 22. Tiling Depending on the manufacturer's software, the examination list screen may display thumbnail-sized images of the examinations. Most often the display includes images recently received by the workstation as the images are acquired during a series of radiographic exposures. Thumbnails vary based on manufacturer specific designs and are selectable. Selecting a thumbnail allows technologists to view a larger image to determine whether it can be accepted or rejected according to the diagnostic principles of the examination. 23. Activity Tracking Modality workstations can track any activity associated with an imaging exam that displays on the workstation comprehensive list, such as date and time. The list of displayed items is configurable but not comprehensive. More examination data is available than is displayed on the exam list screen. For example, the times associated with an examination might include when the imaging order was received by the work list and when the patient's individual images were performed which is based on specific plate processing times, the image capture, and when the image was sent to PACS. 24. Image Data To view an individual study, the user activates a command on the screen showing all the examinations stored on the workstation. The screen then displays information about the images selected that includes the date and time the image is processed, the anatomical menu used to process the image, exposure indicator, which is identified by exposure to the digital receptor, exposure factors, in the case of cassetteless digital imaging systems, brightness level, and contrast level. The data displayed on the image frame and the examination screen can be configured by the user. However, the addition or rejection of certain data fields displayed might be restricted based on an individual technologist s permissions. An image list can offer configurable displays for patient demographics, examination data, image data, and the plate exposure number. Certain users are able to access specific data fields in addition to being able to make general modifications. 25. Knowledge Check 26. Knowledge Check 27. Super Users The terms advanced user and "super user" often apply to technologists with higher levels of access than the rest of the team. Super users can have permission to turn certain data displays on and off and add data to free fields. The configurable areas that advanced users might access include patient demographics, examination data, image data, and plate exposure number. Changes made in these areas often are more complex than simple orders to change the display or add a data column. Super users may control additional data sets or end user access to those data sets. 28. Retrieve To Display Manufacturers provide different types of user controls to manage images, even though the end product is very similar. A touch screen, mouse, or keyboard is used to activate the modality workstation for retrieveto-display commands. As with most computer-based retrieval functions, it s possible to indicate the quantity and sequence of images, or studies, the user wants to retrieve. The display screen provides a retrieval method or methods to step through the images or studies. 29. Editing Image Information The designated privilege levels restrict who can edit and modify images and demographic data. Manufacturers' systems allow varying amounts of change during and after installation. In most cases, the institution and job responsibilities of users drive who can make these changes. It s important to understand that modifying demographic and image data alters the examination and permanent patient record. Therefore, all changes must comply with institutional guidelines. If an order is

6 modified after a work list entry is generated, this change must be described in the patient's chart with an explanatory note. Again, the ability to make these changes depends on the privilege level of the user. 30. Manipulating Image Appearance Editing image data can include altering image orientation, image and display annotation, stitching, applying shuttering or a black border, adjusting image brightness and modifying image contrast. Technologists must follow departmental policy and procedure and standard practice for any and all modifications. Imaging protocols require placing the digital capture device appropriately so that the resulting image is displayed in the proper orientation. On occasion, when a patient's condition or exam parameters make this impossible, modality workstation software allows the image to be rotated or flipped. The image on the left is the original image and the image on the right has been flipped. The ability to flip images makes it critical for the technologist to use lead, left or right side, anatomical markers at the time of image acquisition. Doing so would help to minimize the potential for incorrect placement of electronic left or right side anatomical markers that might be used in addition to lead markers for image acquisition. 31. Image Flip The main processing page on Fuji s cassette-based system allows an image to be flipped. The image is flipped horizontally when the technologist selects the button on the left. This action moves the image much like how you turn the page of a book. When the button immediately to the right of the horizontal flip button is pressed, the image is flipped vertically, or upside down. These buttons can be pressed as many times as necessary until reaching the desired orientation. Konica s cassette-based system also allows an image to be flipped from the main processing page, although the user interface is very different. In this case, a menu of different images is brought up when the technologist selects image flip. These images are thumbnail size and display all the possible variations for flipping the image in horizontal and vertical directions. The technologist can look through the thumbnail images and select the one that presents the desired orientation. The image automatically is flipped once the thumbnail is selected. If the technologist does not approve of this orientation, the entire process can be quickly repeated. 32. Annotating Images Imaging departments have established protocols for the type and placement of the data displayed on a digital image. The actual display may be different on a modality workstation and a PACS workstation. There are a variety of annotations available that can be added to an image keeping in mind that left and right side anatomical markers should always be used during image acquisition for legal reasons. Technologists must include certain basic information on every digital image, just as they do for analog images. Generally, the technologist performing the examination should alter the data, and most systems provide a way to add text. Additional text may include predetermined labels such as, "erect," "10 min" and so forth. Another method adds text by using a free-form text box. When using these display annotations, technologists must follow standard practice and departmental policies and procedure. Fuji s cassette-based system allows image annotation from the processing menu. After the user selects image annotation, a menu of preset annotation markers is displayed. Fuji s system has 7 pages of markers to choose from. The technologist selects the desired marker and then clicks on the image in the general area where the marker should be displayed. The marker is automatically placed on the image where it then can be moved to an exact location and enlarged if necessary. Multiple markers can be placed on the same image. The Fuji cassette-based system also allows technologists to type free text in a marker and place it on the image using a dialog box. A technologist can type a note by clicking on the box in the image annotation menu of the processing main menu. In this case the technologist typed upright. Once the technologist has typed the necessary information, the marker can be placed on the image in the same way that other

7 annotation markers are placed. This marker also can be enlarged and moved to any desired location. Technologists should avoid placing the annotation directly over the anatomy displayed in the image. 33. Stitching For examinations such as a scoliosis series or leg length study in which the anatomical parts are longer than 43 cm, or 17 inches, multiple imaging plates or multiple exposures can be used to acquire the image. When these images are obtained, the equipment provides an indexing mark to ensure that the entire anatomical region is displayed. The technologist can open the processed images on the workstation and use a software function to join the separate images into a single-image format. This process is commonly referred to as stitching. After the cassettes are processed in the correct order, the software uses the identifying markers in the cassettes to join the anatomy, creating a continuous image. 34. Overlapping PSP An alternative to making separate exposures for a scoliosis examination or a long-leg, hip-to-ankle, examination is to use a specially designed cassette. The exam is performed as it would be with a filmscreen image receptor and only 1 exposure is needed. The cassette is designed so that the photostimulable phosphor plates, or PSPs, inside the cassette overlap slightly to cover all the relevant anatomy. Markers inside the cassette assist the stitching software to reconstruct the full-length image. After the exposure is complete, the single cassette on the top is detached from the longer cassette and placed into the plate reader to extract the image. The longer cassette on the bottom contains 2 photostimulable phosphor plates. The cassette is fed from 1 side first to unload 1 PSP. Once the image extraction process is complete for that plate, the cassette is turned around and the final PSP is extracted from the other end of the long cassette. In all, 3 cassettes are processed for a hip-to-ankle examination and 2 plates are processed for a scoliosis exam. It s important to identify the exam to the plate reader before beginning the image extraction process, or the stitching software won t automatically stitch all the images together. A beam-attenuating marker also should be placed on each PSP plate in case an image is misidentified. 35. Image Shuttering A workstation software function allows a black mask to be placed over bright areas which is a practice known as shuttering. Other terms for shuttering include black border, black mask and collimation, although this type of collimation shouldn t be confused with beam restriction. The mask can be configured to apply automatically or manually, depending on the manufacturer. The ability to adjust the mask size depends on the vendor as does the option to select a rectangle, circle, or polygon from the menu and use the computer s mouse to resize the shape to the desired shutter size over the image. Once the technologist has shuttered the image or images to the desired size, the changes are accepted. The area outside of the shuttered area is darkened, although a faint image of the anatomy can still be seen outside the shuttered area. Keep in mind that proper beam restriction, or collimation, to the area of interest is the accepted clinical practice when working with digital equipment. However, when the image is displayed, it is typically surrounded by an unexposed area that appears clear and extremely bright compared with the exposed area. This bright area can result in viewer fatigue when displayed on PACS. The black mask, border or shuttering should not be used in place of effective beam restriction to crop off anatomy. It is critical to apply the black mask or shuttering to an image outside the actual collimated border of the exposure field. This practice is important to show that the technologist exercised prudent judgment in using beam restriction. The Carestream system allows a technologist to shutter an image manually using a function called a mask. The technologist uses a touch-sensitive screen to position the boundaries of the mask in the

8 desired location. Once the lines of the mask have been properly set and accepted, the area outside the shuttered area darkens, making it easier for the radiologist to view the pertinent anatomy. 36. Image Brightness and Contrast Windowing is the term used when changing the clarity and variances of an image. By changing the window levels, the technologist is adjusting what is called the brightness and contrast of that image. Brightness refers to the overall lightness or darkness and contrast is the degree of differences in densities of adjacent structures on an image. The differences in clarity and anatomical structures are manipulated using varying degrees of technical factor selection. 37. Institutional Protocol Although the capabilities of all digital imaging displays are similar, different terminology is used and different processes are followed. It is essential to become familiar with the protocols and equipment used at each facility. 38. Knowledge Check 39. Knowledge Check 40. Conclusion This concludes Essentials of Digital Imaging: Module 3 -- Display. You should now be able to: Differentiate between a cathode ray tube and a liquid crystal display monitor. Define the characteristics of a monitor that affect image display. Explain the features of a modality workstation monitor. Describe how a modality workstation functions. 41. References AAPM Report No An exposure indicator for digital radiography. July American Association of Physicists in Medicine website. Accessed February 14, Bushong SC. Radiologic Science for Technologists: Physics, Biology, and Protection. 10th ed. St Louis, MO: Mosby Elsevier; Carlton RR, Adler AM. Principles of Radiographic Imaging: An Art and A Science. 5th ed. Clifton Park, NY: Thomson Delmar Learning; Carroll QB. Radiography in the Digital Age: Physics, Exposure, Radiation Biology. Springfield, IL: Charles C Thomas; Carter CE, Vealé BL. Digital Radiography and PACS. St Louis, MO; Mosby Elsevier; Practice Standards for Medical Imaging and Radiation Therapy. Radiography practice standards. June 19, American Society of Radiologic Technologists website. Accessed February 14, Seeram E. Digital Radiography: An Introduction for Technologists. Clifton Park, NY: Delmar Cengage Learning; Strategic Document. Version , April 11, Digital Imaging and Communications in Medicine website. Accessed February 14, 2013.

These are used for producing a narrow and sharply focus beam of electrons.

These are used for producing a narrow and sharply focus beam of electrons. CATHOD RAY TUBE (CRT) A CRT is an electronic tube designed to display electrical data. The basic CRT consists of four major components. 1. Electron Gun 2. Focussing & Accelerating Anodes 3. Horizontal

More information

Types of CRT Display Devices. DVST-Direct View Storage Tube

Types of CRT Display Devices. DVST-Direct View Storage Tube Examples of Computer Graphics Devices: CRT, EGA(Enhanced Graphic Adapter)/CGA/VGA/SVGA monitors, plotters, data matrix, laser printers, Films, flat panel devices, Video Digitizers, scanners, LCD Panels,

More information

2.2. VIDEO DISPLAY DEVICES

2.2. VIDEO DISPLAY DEVICES Introduction to Computer Graphics (CS602) Lecture 02 Graphics Systems 2.1. Introduction of Graphics Systems With the massive development in the field of computer graphics a broad range of graphics hardware

More information

Chapter 3. Display Devices and Interfacing

Chapter 3. Display Devices and Interfacing Chapter 3 Display Devices and Interfacing Monitor Details Collection of dots Matrix of dots creates character Monochrome monitor screen is collection of 350 *720 350 rows and each rows having 720 dots

More information

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide Use of the Guide Carestream CR Systems are designed to meet international safety and performance standards. Personnel operating

More information

CARESTREAM DIRECTVIEW Elite CR System

CARESTREAM DIRECTVIEW Elite CR System CARESTREAM DIRECTVIEW Elite CR System Improve workflow, productivity, and patient throughput. The CARESTREAM DIRECTVIEW Elite CR System is small, easy to install and easy to use. This powerful distributed

More information

Reading. Display Devices. Light Gathering. The human retina

Reading. Display Devices. Light Gathering. The human retina Reading Hear & Baker, Computer graphics (2 nd edition), Chapter 2: Video Display Devices, p. 36-48, Prentice Hall Display Devices Optional.E. Sutherland. Sketchpad: a man-machine graphics communication

More information

CARESTREAM DIRECTVIEW Elite CR System

CARESTREAM DIRECTVIEW Elite CR System CARESTREAM DIRECTVIEW Elite CR System Improve workflow, productivity, and patient throughput. The CARESTREAM DIRECTVIEW Elite CR System is small, easy to install and easy to use. This powerful distributed

More information

Comp 410/510. Computer Graphics Spring Introduction to Graphics Systems

Comp 410/510. Computer Graphics Spring Introduction to Graphics Systems Comp 410/510 Computer Graphics Spring 2018 Introduction to Graphics Systems Computer Graphics Computer graphics deals with all aspects of 'creating images with a computer - Hardware (PC with graphics card)

More information

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba Equipment Quality Control for Digital Radiography February 22, 2018 Imaging Physics CancerCare Manitoba Purpose An equipment quality control (QC) program establishes baseline performance levels, tracks

More information

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

DirectView Elite CR System. Improve workflow, productivity, and patient throughput. Improve workflow, productivity, and patient throughput. DirectView DirectView Compact, single cassette CR systems designed to improve workflow, productivity, and patient throughput. The is small, easy

More information

1 Your computer screen

1 Your computer screen U.S.T.H.B / C.E.I.L Unit 7 Computer science L2 (S2) 1 Your computer screen Discuss the following questions. 1 What type of display do you have? 2 What size is the screen? 3 Can you watch TV on your PC

More information

Display Systems. Viewing Images Rochester Institute of Technology

Display Systems. Viewing Images Rochester Institute of Technology Display Systems Viewing Images 1999 Rochester Institute of Technology In This Section... We will explore how display systems work. Cathode Ray Tube Television Computer Monitor Flat Panel Display Liquid

More information

Reading. 1. Displays and framebuffers. History. Modern graphics systems. Required

Reading. 1. Displays and framebuffers. History. Modern graphics systems. Required Reading Required 1. Displays and s Angel, pp.19-31. Hearn & Baker, pp. 36-38, 154-157. OpenGL Programming Guide (available online): First four sections of chapter 2 First section of chapter 6 Optional

More information

Objectives: Topics covered: Basic terminology Important Definitions Display Processor Raster and Vector Graphics Coordinate Systems Graphics Standards

Objectives: Topics covered: Basic terminology Important Definitions Display Processor Raster and Vector Graphics Coordinate Systems Graphics Standards MODULE - 1 e-pg Pathshala Subject: Computer Science Paper: Computer Graphics and Visualization Module: Introduction to Computer Graphics Module No: CS/CGV/1 Quadrant 1 e-text Objectives: To get introduced

More information

3. Displays and framebuffers

3. Displays and framebuffers 3. Displays and framebuffers 1 Reading Required Angel, pp.19-31. Hearn & Baker, pp. 36-38, 154-157. Optional Foley et al., sections 1.5, 4.2-4.5 I.E. Sutherland. Sketchpad: a man-machine graphics communication

More information

Part 1: Introduction to computer graphics 1. Describe Each of the following: a. Computer Graphics. b. Computer Graphics API. c. CG s can be used in

Part 1: Introduction to computer graphics 1. Describe Each of the following: a. Computer Graphics. b. Computer Graphics API. c. CG s can be used in Part 1: Introduction to computer graphics 1. Describe Each of the following: a. Computer Graphics. b. Computer Graphics API. c. CG s can be used in solving Problems. d. Graphics Pipeline. e. Video Memory.

More information

High-resolution screens have become a mainstay on modern smartphones. Initial. Displays 3.1 LCD

High-resolution screens have become a mainstay on modern smartphones. Initial. Displays 3.1 LCD 3 Displays Figure 3.1. The University of Texas at Austin s Stallion Tiled Display, made up of 75 Dell 3007WPF LCDs with a total resolution of 307 megapixels (38400 8000 pixels) High-resolution screens

More information

+ Human method is pattern recognition based upon multiple exposure to known samples.

+ Human method is pattern recognition based upon multiple exposure to known samples. Main content + Segmentation + Computer-aided detection + Data compression + Image facilities design + Human method is pattern recognition based upon multiple exposure to known samples. + We build up mental

More information

Reading. Displays and framebuffers. Modern graphics systems. History. Required. Angel, section 1.2, chapter 2 through 2.5. Related

Reading. Displays and framebuffers. Modern graphics systems. History. Required. Angel, section 1.2, chapter 2 through 2.5. Related Reading Required Angel, section 1.2, chapter 2 through 2.5 Related Displays and framebuffers Hearn & Baker, Chapter 2, Overview of Graphics Systems OpenGL Programming Guide (the red book ): First four

More information

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline Medical Display Performance and Evaluation Mike Silosky, MS University of Colorado, School of Medicine Dept. of Radiology 1 Objectives Review display function, QA metrics, procedures, and guidance provided

More information

CMPE 466 COMPUTER GRAPHICS

CMPE 466 COMPUTER GRAPHICS 1 CMPE 466 COMPUTER GRAPHICS Chapter 2 Computer Graphics Hardware Instructor: D. Arifler Material based on - Computer Graphics with OpenGL, Fourth Edition by Donald Hearn, M. Pauline Baker, and Warren

More information

2.4.1 Graphics. Graphics Principles: Example Screen Format IMAGE REPRESNTATION

2.4.1 Graphics. Graphics Principles: Example Screen Format IMAGE REPRESNTATION 2.4.1 Graphics software programs available for the creation of computer graphics. (word art, Objects, shapes, colors, 2D, 3d) IMAGE REPRESNTATION A computer s display screen can be considered as being

More information

Displays. History. Cathode ray tubes (CRTs) Modern graphics systems. CSE 457, Autumn 2003 Graphics. » Whirlwind Computer - MIT, 1950

Displays. History. Cathode ray tubes (CRTs) Modern graphics systems. CSE 457, Autumn 2003 Graphics. » Whirlwind Computer - MIT, 1950 History Displays CSE 457, Autumn 2003 Graphics http://www.cs.washington.edu/education/courses/457/03au/» Whirlwind Computer - MIT, 1950 CRT display» SAGE air-defense system - middle 1950 s Whirlwind II

More information

CS2401-COMPUTER GRAPHICS QUESTION BANK

CS2401-COMPUTER GRAPHICS QUESTION BANK SRI VENKATESWARA COLLEGE OF ENGINEERING AND TECHNOLOGY THIRUPACHUR. CS2401-COMPUTER GRAPHICS QUESTION BANK UNIT-1-2D PRIMITIVES PART-A 1. Define Persistence Persistence is defined as the time it takes

More information

Display Technologies CMSC 435. Slides based on Dr. Luebke s slides

Display Technologies CMSC 435. Slides based on Dr. Luebke s slides Display Technologies CMSC 435 Slides based on Dr. Luebke s slides Recap: Transforms Basic 2D Transforms: Scaling, Shearing, Rotation, Reflection, Composition of 2D Transforms Basic 3D Transforms: Rotation,

More information

Radiography and Mammography Viewing Systems

Radiography and Mammography Viewing Systems Radiography and Mammography Viewing Systems For assistance contact your authorized RADX Dealer, or call S&S Technology at 800-231-1747 E-mail salessupport@radx.com www.ssxray.com Mammography Digital Viewing

More information

Display Devices & its Interfacing

Display Devices & its Interfacing Display Devices & its Interfacing 3 Display systems are available in various technologies such as i) Cathode ray tubes (CRTs), ii) Liquid crystal displays (LCDs), iii) Plasma displays, and iv) Light emitting

More information

Module 7. Video and Purchasing Components

Module 7. Video and Purchasing Components Module 7 Video and Purchasing Components Objectives 1. PC Hardware A.1.11 Evaluate video components and standards B.1.10 Evaluate monitors C.1.9 Evaluate and select appropriate components for a custom

More information

Monitor QA Management i model

Monitor QA Management i model Monitor QA Management i model 1/10 Monitor QA Management i model Table of Contents 1. Preface ------------------------------------------------------------------------------------------------------- 3 2.

More information

This talk covers currently available display technology.

This talk covers currently available display technology. Introduction to Current Display Technologies for Medical Image Viewing Perspectives for the TG270 Update on Display Quality Control Alisa Walz-Flannigan, PhD (DABR) Mayo Clinic, Rochester, Minnesota AAPM

More information

Introduction to Computer Graphics

Introduction to Computer Graphics Introduction to Computer Graphics R. J. Renka Department of Computer Science & Engineering University of North Texas 01/16/2010 Introduction Computer Graphics is a subfield of computer science concerned

More information

Part 1: Introduction to Computer Graphics

Part 1: Introduction to Computer Graphics Part 1: Introduction to Computer Graphics 1. Define computer graphics? The branch of science and technology concerned with methods and techniques for converting data to or from visual presentation using

More information

PTIK UNNES. Lecture 02. Conceptual Model for Computer Graphics and Graphics Hardware Issues

PTIK UNNES. Lecture 02. Conceptual Model for Computer Graphics and Graphics Hardware Issues E3024031 KOMPUTER GRAFIK E3024032 PRAKTIK KOMPUTER GRAFIK PTIK UNNES Lecture 02 Conceptual Model for Computer Graphics and Graphics Hardware Issues 2014 Learning Objectives After carefully listening this

More information

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology High Frequency X-Ray Technology Wide Screen Control with Touch-Technology The Q-VISION HF Series TM The Q-VISION Series TM integrates innovative high frequency design along with superb functionality, resulting

More information

Monitor and Display Adapters UNIT 4

Monitor and Display Adapters UNIT 4 Monitor and Display Adapters UNIT 4 TOPIC TO BE COVERED: 4.1: video Basics(CRT Parameters) 4.2: VGA monitors 4.3: Digital Display Technology- Thin Film Displays, Liquid Crystal Displays, Plasma Displays

More information

Basically we are fooling our brains into seeing still images at a fast enough rate so that we think its a moving image.

Basically we are fooling our brains into seeing still images at a fast enough rate so that we think its a moving image. Basically we are fooling our brains into seeing still images at a fast enough rate so that we think its a moving image. The formal definition of a Moving Picture... A sequence of consecutive photographic

More information

CHAPTER 4 OSCILLOSCOPES

CHAPTER 4 OSCILLOSCOPES CHAPTER 4 OSCILLOSCOPES 4.1 Introduction The cathode ray oscilloscope generally referred to as the oscilloscope, is probably the most versatile electrical measuring instrument available. Some of electrical

More information

JEFFERSON COLLEGE. Image Intensification & Equipment

JEFFERSON COLLEGE. Image Intensification & Equipment JEFFERSON COLLEGE COURSE SYLLABUS RAD175 Image Intensification & Equipment 3 Credit Hours Revised by: Janet E. Akers BS RT (R)(M) Date: October 3, 2013 Kenny Wilson, Director, Health Occupation Programs

More information

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria Nicholas B. Bevins, Ph.D. TG270 Co-chair Display Check 2 1 TG270 Goals Provide an update

More information

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria Nicholas B. Bevins, Ph.D. TG270 Co-chair Display Check 2 TG270 Goals Provide an update to

More information

General Items: Reading Materials: Miscellaneous: Lecture 8 / Chapter 6 COSC1300/ITSC 1401/BCIS /19/2004. Tests? Questions? Anything?

General Items: Reading Materials: Miscellaneous: Lecture 8 / Chapter 6 COSC1300/ITSC 1401/BCIS /19/2004. Tests? Questions? Anything? General Items: Tests? Questions? Anything? Reading Materials: Miscellaneous: F.Farahmand 1 / 14 File: lec7chap6f04.doc What is output? - A computer processes the data and generates output! - Also known

More information

D-ILA PROJECTOR DLA-G15 DLA-S15

D-ILA PROJECTOR DLA-G15 DLA-S15 D-ILA PROJECTOR DLA-G15 Outstanding Projection Im Breakthrough D-ILA projector offers high-contrast 350:1, 1500 ANSI lumen brightness and S-XGA resolution Large-size projection images with all the sharpness

More information

Computer Graphics Hardware

Computer Graphics Hardware Computer Graphics Hardware Kenneth H. Carpenter Department of Electrical and Computer Engineering Kansas State University January 26, 2001 - February 5, 2004 1 The CRT display The most commonly used type

More information

Guidelines for Assuring Softcopy Image Quality

Guidelines for Assuring Softcopy Image Quality Guidelines for Assuring Softcopy Image Quality What s inside? Quality Control Guidelines Softcopy QA testing and frequencies Danny Deroo Product and R&D Manager QA Products ABSTRACT To ensure diagnostic

More information

CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR

CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR OSCILLOSCOPE 3.1 Introduction The cathode ray oscilloscope (CRO) provides a visual presentation of any waveform applied to the input terminal. The oscilloscope

More information

Display Quality Assurance: Considerations When Establishing a Display QA Program. Mike Silosky, M.S. 8/3/2017

Display Quality Assurance: Considerations When Establishing a Display QA Program. Mike Silosky, M.S. 8/3/2017 Display Quality Assurance: Considerations When Establishing a Display QA Program Mike Silosky, M.S. 8/3/2017 Objectives and Outline Why, Who, What, When, Where? Discuss the resources that may be needed

More information

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison Sep 09, 2002 APPLICATION NOTE 1193 Electronic s Comparison Abstract: This note compares advantages and disadvantages of Cathode Ray Tubes, Electro-Luminescent, Flip- Dot, Incandescent Light Bulbs, Liquid

More information

BUREAU OF ENERGY EFFICIENCY

BUREAU OF ENERGY EFFICIENCY Date: 26 th May, 2016 Schedule No.: 11 Color Televisions 1. Scope This schedule specifies the energy labeling requirements for color televisions with native resolution upto 1920 X 1080 pixels, of CRT,

More information

iii Table of Contents

iii Table of Contents i iii Table of Contents Display Setup Tutorial....................... 1 Launching Catalyst Control Center 1 The Catalyst Control Center Wizard 2 Enabling a second display 3 Enabling A Standard TV 7 Setting

More information

ENERGY STAR Program Requirements Product Specification for Televisions. Eligibility Criteria Version 5.3

ENERGY STAR Program Requirements Product Specification for Televisions. Eligibility Criteria Version 5.3 ENERGY STAR Program Requirements Product Specification for Televisions Eligibility Criteria Version 5.3 Following is the Version 5.3 ENERGY STAR Product Specification for Televisions. A product shall meet

More information

PROFESSIONAL D-ILA PROJECTOR DLA-G11

PROFESSIONAL D-ILA PROJECTOR DLA-G11 PROFESSIONAL D-ILA PROJECTOR DLA-G11 A new digital projector that projects true S-XGA images with breakthrough D-ILA technology Large-size projection images with all the sharpness and clarity of a small-screen

More information

1. Introduction. 1.1 Graphics Areas. Modeling: building specification of shape and appearance properties that can be stored in computer

1. Introduction. 1.1 Graphics Areas. Modeling: building specification of shape and appearance properties that can be stored in computer 1. Introduction 1.1 Graphics Areas Modeling: building specification of shape and appearance properties that can be stored in computer Rendering: creation of shaded images from 3D computer models 2 Animation:

More information

Computer Graphics : Unit - I

Computer Graphics : Unit - I Computer Graphics Unit 1 Introduction: Computer Graphics it is a set of tools to create, manipulate and interact with pictures. Data is visualized through geometric shapes, colors and textures. Video Display

More information

Dental Line. High frequency intraoral x-ray unit. radiology ahead

Dental Line. High frequency intraoral x-ray unit. radiology ahead Dental Line High frequency intraoral x-ray unit radiology ahead enhance your operating process Hi-frequency generator, for shorter exposures and reduced dose Wireless X-ray pushbutton, available for ultimate

More information

Ride the Lightning. A Review of Radiographic Physics

Ride the Lightning. A Review of Radiographic Physics Ride the Lightning A Review of Radiographic Physics Overview Basic principles of x-ray production Imaging equipment Quality Control Technical Factors Image QA Preparing for the registry The ARRT just wants

More information

B. TECH. VI SEM. I MID TERM EXAMINATION 2018

B. TECH. VI SEM. I MID TERM EXAMINATION 2018 B. TECH. VI SEM. I MID TERM EXAMINATION 2018 BRANCH : COMPUTER SCIENCE ENGINEERING ( CSE ) SUBJECT : 6CS4A COMPUTER GRAPHICS & MULTIMEDIA TECHNIQUES Q 1. Write down mid point ellipse drawing algorithm.

More information

Technical Developments for Widescreen LCDs, and Products Employed These Technologies

Technical Developments for Widescreen LCDs, and Products Employed These Technologies Technical Developments for Widescreen LCDs, and Products Employed These Technologies MIYAMOTO Tsuneo, NAGANO Satoru, IGARASHI Naoto Abstract Following increases in widescreen representations of visual

More information

Overview of Graphics Systems

Overview of Graphics Systems CHAPTER - 2 Overview of Graphics Systems Video Display Devices Instructions are stored in a display memory display file display list Modes: immediate each element is processed and displayed retained objects

More information

MX215. Your advantages. 2MP Medical-Display

MX215. Your advantages. 2MP Medical-Display MX215 Your advantages The EIZO MX215 features factory-preset DICOM tonal values and displays greyscale tones of radiological images in accordance with the requirements of the object. The advantage here

More information

D-ILA PROJECTOR DLA-G15 DLA-S15

D-ILA PROJECTOR DLA-G15 DLA-S15 D-ILA PROJECTOR Outstanding Projection Im Breakthrough D-ILA projector offers high-contrast 350:1, 1500 ANSI lumen brightness and S-XGA resolution Large-size projection images with all the sharpness and

More information

Computer Graphics: Overview of Graphics Systems

Computer Graphics: Overview of Graphics Systems Computer Graphics: Overview of Graphics Systems By: A. H. Abdul Hafez Abdul.hafez@hku.edu.tr, 1 Outlines 1. Video Display Devices 2. Flat-panel displays 3. Video controller and Raster-Scan System 4. Coordinate

More information

PROFESSIONAL D-ILA PROJECTOR DLA-G11

PROFESSIONAL D-ILA PROJECTOR DLA-G11 PROFESSIONAL D-ILA PROJECTOR DLA-G11 A new digital projector that projects true S-XGA images with breakthrough D-ILA technology Large-size projection images with all the sharpness and clarity of a small-screen

More information

Computer Graphics Prof. Sukhendu Das Dept. of Computer Science and Engineering Indian Institute of Technology, Madras Lecture - 5 CRT Display Devices

Computer Graphics Prof. Sukhendu Das Dept. of Computer Science and Engineering Indian Institute of Technology, Madras Lecture - 5 CRT Display Devices Computer Graphics Prof. Sukhendu Das Dept. of Computer Science and Engineering Indian Institute of Technology, Madras Lecture - 5 CRT Display Devices Hello everybody, welcome back to the lecture on Computer

More information

MODULE I MCA COMPUTER GRAPHICS ADMN APPLICATIONS OF COMPUTER GRAPHICS

MODULE I MCA COMPUTER GRAPHICS ADMN APPLICATIONS OF COMPUTER GRAPHICS MODULE 1 1. APPLICATIONS OF COMPUTER GRAPHICS Computer graphics is used in a lot of areas such as science, engineering, medicine, business, industry, government, art, entertainment, advertising, education

More information

Table of content. Table of content Introduction Concepts Hardware setup...4

Table of content. Table of content Introduction Concepts Hardware setup...4 Table of content Table of content... 1 Introduction... 2 1. Concepts...3 2. Hardware setup...4 2.1. ArtNet, Nodes and Switches...4 2.2. e:cue butlers...5 2.3. Computer...5 3. Installation...6 4. LED Mapper

More information

Lecture Flat Panel Display Devices

Lecture Flat Panel Display Devices Lecture 13 6.111 Flat Panel Display Devices Outline Overview Flat Panel Display Devices How do Displays Work? Emissive Displays Light Valve Displays Display Drivers Addressing Schemes Display Timing Generator

More information

Design of VGA Controller using VHDL for LCD Display using FPGA

Design of VGA Controller using VHDL for LCD Display using FPGA International OPEN ACCESS Journal Of Modern Engineering Research (IJMER) Design of VGA Controller using VHDL for LCD Display using FPGA Khan Huma Aftab 1, Monauwer Alam 2 1, 2 (Department of ECE, Integral

More information

decodes it along with the normal intensity signal, to determine how to modulate the three colour beams.

decodes it along with the normal intensity signal, to determine how to modulate the three colour beams. Television Television as we know it today has hardly changed much since the 1950 s. Of course there have been improvements in stereo sound and closed captioning and better receivers for example but compared

More information

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency CATHODE RAY OSCILLOSCOPE Basic block diagrams Principle of operation Measurement of voltage, current and frequency 103 INTRODUCTION: The cathode-ray oscilloscope (CRO) is a multipurpose display instrument

More information

L14 - Video. L14: Spring 2005 Introductory Digital Systems Laboratory

L14 - Video. L14: Spring 2005 Introductory Digital Systems Laboratory L14 - Video Slides 2-10 courtesy of Tayo Akinwande Take the graduate course, 6.973 consult Prof. Akinwande Some modifications of these slides by D. E. Troxel 1 How Do Displays Work? Electronic display

More information

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO) 2141274 Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University Cathode-Ray Oscilloscope (CRO) Objectives You will be able to use an oscilloscope to measure voltage, frequency

More information

Performance Evaluation of Industrial Computed Radiography Image Display System

Performance Evaluation of Industrial Computed Radiography Image Display System Performance Evaluation of Industrial Computed Radiography Image Display System More info about this article: http://www.ndt.net/?id=21169 Lakshminarayana Yenumula *, Rajesh V Acharya, Umesh Kumar, and

More information

BID SPECIFICATION FOR PRODUCTION CRT MONITORS

BID SPECIFICATION FOR PRODUCTION CRT MONITORS BID SPECIFICATION FOR PRODUCTION CRT MONITORS MODEL NUMBER PVM-136 INSTRUCTIONS: REMOVE THIS COVER PAGE AND ADD TO REQUESTS FOR QUOTATION AND PROPOSALS. THE OBJECTIVE OF THIS BID SPECIFICATION IS TO ASSIST

More information

How to Match the Color Brightness of Automotive TFT-LCD Panels

How to Match the Color Brightness of Automotive TFT-LCD Panels Relative Luminance How to Match the Color Brightness of Automotive TFT-LCD Panels Introduction The need for gamma correction originated with the invention of CRT TV displays. The CRT uses an electron beam

More information

The Cathode Ray Tube

The Cathode Ray Tube Lesson 2 The Cathode Ray Tube The Cathode Ray Oscilloscope Cathode Ray Oscilloscope Controls Uses of C.R.O. Electric Flux Electric Flux Through a Sphere Gauss s Law The Cathode Ray Tube Example 7 on an

More information

MX215. Your advantages. 2MP Medical-Display

MX215. Your advantages. 2MP Medical-Display MX215 Your advantages The EIZO MX215 features factory-preset DICOM tonal values and displays greyscale tones of radiological images in accordance with the requirements of the object. The advantage here

More information

Beyond the Resolution: How to Achieve 4K Standards

Beyond the Resolution: How to Achieve 4K Standards Beyond the Resolution: How to Achieve 4K Standards The following article is inspired by the training delivered by Adriano D Alessio of the Lightware a leading manufacturer of DVI, HDMI, and DisplayPort

More information

Understanding Multimedia - Basics

Understanding Multimedia - Basics Understanding Multimedia - Basics Joemon Jose Web page: http://www.dcs.gla.ac.uk/~jj/teaching/demms4 Wednesday, 9 th January 2008 Design and Evaluation of Multimedia Systems Lectures video as a medium

More information

Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel:

Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel: Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel:+82-31-737-2211 Fax:+82-31-737-2210 Factory 236-4 Sangdaewon-dong, Seongnam-si,

More information

VIDEO 101 LCD MONITOR OVERVIEW

VIDEO 101 LCD MONITOR OVERVIEW VIDEO 101 LCD MONITOR OVERVIEW This provides an overview of the monitor nomenclature and specifications as they relate to TRU-Vu industrial monitors. This is an ever changing industry and as such all specifications

More information

Guidance for Quality Assurance of PACS Diagnostic Display Devices

Guidance for Quality Assurance of PACS Diagnostic Display Devices Guidance for Quality Assurance of PACS Diagnostic Display Programme NPFIT DOCUMENT RECORD ID KEY Sub-Prog / PACS Project NPFIT-PAC-DES-0042.06 Prog. Director Max Jones Owner Jerry Norman Version 1.0 Author

More information

DCI Memorandum Regarding Direct View Displays

DCI Memorandum Regarding Direct View Displays 1. Introduction DCI Memorandum Regarding Direct View Displays Approved 27 June 2018 Digital Cinema Initiatives, LLC, Member Representatives Committee Direct view displays provide the potential for an improved

More information

How to Chose an Ideal High Definition Endoscopic Camera System

How to Chose an Ideal High Definition Endoscopic Camera System How to Chose an Ideal High Definition Endoscopic Camera System Telescope Laparoscopy (from Greek lapara, "flank or loin", and skopein, "to see, view or examine") is an operation performed within the abdomen

More information

CATHODE-RAY OSCILLOSCOPE (CRO)

CATHODE-RAY OSCILLOSCOPE (CRO) CATHODE-RAY OSCILLOSCOPE (CRO) I N T R O D U C T I O N : The cathode-ray oscilloscope (CRO) is a multipurpose display instrument used for the observation, measurement, and analysis of waveforms by plotting

More information

OUTPUT DEVICES MONITORS

OUTPUT DEVICES MONITORS OUTPUT DEVICES MONITORS Task 1 Describe the monitor of your computer Is it a monochrome or a colour monitor? What size is the screen? Does it have a cathode ray tube or a flat LCD screen? How can you change

More information

Samsung LED technology A cost-effective, eco-friendly alternative to conventional LCD technology

Samsung LED technology A cost-effective, eco-friendly alternative to conventional LCD technology Samsung LED technology A cost-effective, eco-friendly alternative to conventional LCD technology Contents Introduction 3 Samsung LED screens outperform CCFL screens in picture quality and reliability 3

More information

Introduction...2. Features...2 Safety Precautions...2. Installation...4

Introduction...2. Features...2 Safety Precautions...2. Installation...4 PE1900 Contents Introduction...2 Features...2 Safety Precautions...2 Installation...4 Unpacking the Display...4 Locations and Functions of Controls...4 Connections...5 Using Your Display...7 Turning the

More information

Scope: All CT staff technologist

Scope: All CT staff technologist APPROVED BY: Radiology Technical Director Page 1 of 6 Purpose: The QC program assesses relative changes in system performance as determined by the technologist, service engineer, qualified medical physicist,

More information

2G Video Wall Guide Just Add Power HD over IP Page1 2G VIDEO WALL GUIDE. Revised

2G Video Wall Guide Just Add Power HD over IP Page1 2G VIDEO WALL GUIDE. Revised 2G Video Wall Guide Just Add Power HD over IP Page1 2G VIDEO WALL GUIDE Revised 2016-05-09 2G Video Wall Guide Just Add Power HD over IP Page2 Table of Contents Specifications... 4 Requirements for Setup...

More information

MODEL NUMBER PVM-20L5

MODEL NUMBER PVM-20L5 BID SPECIFICATION FOR PRODUCTION CRT MONITORS MODEL NUMBER PVM-20L5 INSTRUCTIONS: REMOVE THIS COVER PAGE AND ADD TO REQUESTS FOR QUOTATION AND PROPOSALS. THE OBJECTIVE OF THIS BID SPECIFICATION IS TO ASSIST

More information

Global Trade Medical Supplies

Global Trade Medical Supplies Features: Achieve Clarity True to the Source Data A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD

More information

Module 1: Digital Video Signal Processing Lecture 3: Characterisation of Video raster, Parameters of Analog TV systems, Signal bandwidth

Module 1: Digital Video Signal Processing Lecture 3: Characterisation of Video raster, Parameters of Analog TV systems, Signal bandwidth The Lecture Contains: Analog Video Raster Interlaced Scan Characterization of a video Raster Analog Color TV systems Signal Bandwidth Digital Video Parameters of a digital video Pixel Aspect Ratio file:///d

More information

Digital High Resolution Display Technology. A New Way of Seeing Things.

Digital High Resolution Display Technology. A New Way of Seeing Things. R Digital High Resolution Display Technology A New Way of Seeing Things. Raytheon s Digital Display Digital Light Processing (DLP ) by Texas Instruments is a revolutionary new way to project and display

More information

Understanding PQR, DMOS, and PSNR Measurements

Understanding PQR, DMOS, and PSNR Measurements Understanding PQR, DMOS, and PSNR Measurements Introduction Compression systems and other video processing devices impact picture quality in various ways. Consumers quality expectations continue to rise

More information

DISPLAY TECHNOLOGIES. Group 6: Steve Lenhart, Ryan King, Ramsey Akl, and Andrew Scheib

DISPLAY TECHNOLOGIES. Group 6: Steve Lenhart, Ryan King, Ramsey Akl, and Andrew Scheib DISPLAY TECHNOLOGIES Group 6: Steve Lenhart, Ryan King, Ramsey Akl, and Andrew Scheib DISPLAY TECHNOLOGIES Group 6: Steve Lenhart, Ryan King, Ramsey Akl, and Andrew Scheib Introduction First computers

More information

1. General Description

1. General Description LP2X05 Product Specification. General Description The LP2X05 is a Color Active Matrix with an integral Cold Cathode Fluorescent Lamp(CCFL) backlight system. The matrix employs asi Thin Film Transistor

More information

Power Consumption Trends in Digital TVs produced since 2003

Power Consumption Trends in Digital TVs produced since 2003 Power Consumption Trends in Digital TVs produced since 2003 Prepared by Darrell J. King And Ratcharit Ponoum TIAX LLC 35 Hartwell Avenue Lexington, MA 02421 TIAX Reference No. D0543 for Consumer Electronics

More information

Technology White Paper Plasma Displays. NEC Technologies Visual Systems Division

Technology White Paper Plasma Displays. NEC Technologies Visual Systems Division Technology White Paper Plasma Displays NEC Technologies Visual Systems Division May 1998 1 What is a Color Plasma Display Panel? The term Plasma refers to a flat panel display technology that utilizes

More information

Computer Graphics. Introduction

Computer Graphics. Introduction Computer Graphics Introduction Introduction Computer Graphics : It involves display manipulation and storage of pictures and experimental data for proper visualization using a computer. Typically graphics

More information