1 DF Series Manual

2 DF Series Manual Version DF Series Manual Version /60

3 Inhalt 1 Introduction Manufacture Safety instruction Quickstart guide Unpacking and installation Webbrowser Network connection Network settings [Windows 7] Proxy configuration [Windows 7] Web interface Mounting Placement Website guide Homepage Signalbar Newdata Power supply Alarm settings Torquemeter Measuring Analog settings Frequency settings Filter settings CAN settings CAN state CAN configuration State Ethernet settings General settings Service page Technical specs Pinallocations X770 Power supply / Frequency output X771 Analogue / CAN / Alarm / Input X772 Ethernet X773 Central cable General technical data High resolution speed encoder option Mechanical data DF Series Manual Version /60

4 6.8.1 Single sided clutch device Dimension rotor DF standard type [mm] Dimension stator Dimension TCUIV Dimension with couplings Torque and acceleration DF Series Manual Version /60

5 1 Introduction Dear customer, before leaving our company every unit is tested by extensive function and quality examinations, which guarantee that the system complies with the stated specifications. Nevertheless should there be any problem, please contact us. Before shipping a system, the serial number of each component of your configuration is registered by our company, so that an individual and short-term support can be guaranteed. It is understood that we will inform you about innovations and modifications of the system 1.1 Manufacture Konrad-Zuse-Str Alsdorf Phone: +49 (0) Fax: +49 (0) info@atesteo.com DF Series Manual Version /60

6 2 Safety instruction The Manual must be read carefully before start-up, maintenance work or any other work on the torque measuring system. Prerequisite for the safe and proper handling of the equipment knows all safety instructions and safety regulations of the attachment. Every safeguard needs to be correctly mounted and fully functional before any start-up. Measurement shafts mounted to the torque meter must be properly designed, so that critical bending speed is avoided. Exclusively qualified laborers are allowed to do maintenance work on any electrical components. Note Improper use and handling as well as constructional changes will invalidate the EC declaration of conformity. DF Series Manual Version /60

7 3 Quickstart guide 3.1 Unpacking and installation The package contains the following items 1 : 1. Torque meter (Rotor) 2. DF-Stator 3. TCU IV (Torque Control Unit) 4. Central cable pin connector pin connector Follow the next instructions to connect the system. Mount torque meter and antenna as described in the 2 Mounting guide Connect DF-Stator and TCU IV with the central cable Connect the 12-pin and 16-pin connectors to the TCU IV Note Pin allocations are specified under 4 TECHNICAL SPECS Important Power supply pins are mandatory. Power supply rating: 24V±1V/1A 1 Depending on your order he delivery content can vary DF Series Manual Version /60

8 3.2 Webbrowser One of the following web browsers is required, to use the web interface: Firefox Chrome Internet Explorer If none of the browsers is installed yet, follow the instruction after downloading the browser. Note Please use the latest version of the browser DF Series Manual Version /60

9 3.3 Network connection Before startup ensure that the TCU IV is connected properly. Please check: Central cable of Receiver Correct Position of Receiver Power supply connection Requires: Patch cable with RJ45 connector Three options to connect to network: 1. Connect in domain network: Connect the TCU IV using the patch cable with a free network socket. 2. Connect with network-to-usb adapter: The adapter needs to be installed on the computer. Now connect TCU IV with a patch cable to the adapter. 3. Connect directly Connect with a patch cable directly from the Ethernet socket of the computer. DF Series Manual Version /60

10 3.4 Network settings [Windows 7] Network settings need to be changed, if option one or two is selected. 1. Open Control Panel 2. Navigate to Network and Sharing Center 3. Open the Status window of the connection 4. To open Connection Properties click on 5. Select Internet Protocol Version 4 and click on 6. Enter the following values a. IP address: b. Subnet mask: Note Administrator rights are required DF Series Manual Version /60

11 DF Series Manual Version /60

12 DF Series Manual Version /60

13 3.5 Proxy configuration [Windows 7] 1. Open Control Panel 2. Navigate to Internet Properties 3. Choose the Connections tab 4. Click on 5. Navigate to Proxy Settings by clicking 6. Input the new proxy exception a. Proxy exception: * DF Series Manual Version /60

14 DF Series Manual Version /60

15 4. LAN Settings 5. Proxy Settings DF Series Manual Version /60

16 3.6 Web interface The web address of the TCU IV is needed to open the web interface. The web address contains of "torque20-" and [SERIAL NUMBER]. Use the following IP address to open the web interface: Or use the following web address (requires a DNS-Server): NUMBER] The serial number can be seen on the type label of the TCU. Note Type in the serial number without "[ ]" and ignore "TCUIV-" on the type label. DF Series Manual Version /60

17 4 Mounting Mounting torque meter with input side to drive train. Type Amount of screws Tightening torque DF1 6x M Nm DF2 8x M Nm DF3 8x M Nm DF4 8x M Nm DF5 8x M Nm DF Series Manual Version /60

18 4.1 Placement Outer edge oft he flange The DF stator must be positioned under the measuring flange that the output flange of the rotor covers the black area of the stator. Note: Radial air-gap between receiver and torque-meter: 3mm +1mm /-2mm. Axial displacement of black area: ±1mm DF Series Manual Version /60

19 The following images show the placement options with and without the speed option. Optimal 6mm DF Series Manual Version /60

20 5 Website guide LOGIN Web interface is opened as described in the quick start guide. The login password must be entered. By default the password is: admin. Important The password can be changed in the menu item Settings. Protect your device against unauthorized access! DF Series Manual Version /60

21 5.1 Homepage The login leads to the homepage. Device information: This overview of currently connected devices includes information about the name of the TCU and the serial number of the stator and the torque sensor. The device name is editable in the Settings menu. Measurement features. The measuring signal is set to zero by pushing the button. The test signals are enabled or disabled by the buttons. DF Series Manual Version /60

22 Test signal [controller] generates a full-scale deflection on every system output independent of the measured inputs. Test signal [torque sensor] generates a half-scale deflection at the torque sensor of torque input 1 and 2. The deflection is generated by an offset jump of the first amplifiers of the respective measurement chain. Note: Test signals must be disabled before measuring DF Series Manual Version /60

23 Graph overview Diverse signals are displayed in the main part of the home page. These signals graphically represent Torque input 1, Torque input 2 2, Acceleration input 1, the Speed input 1 and the Temperature of the torque sensor. Graphs are automatically scaled according to their nominal value. Note Signals are not displayed in real-time. This may lead to delayed representations. Navigation menu If the navigation bar is closed, click on the company logo to open it again. 2 Depending on the configuration of the current system DF Series Manual Version /60

24 5.2 Signalbar The signal bar is shown on the right-hand side of the website. General states B A C The General tab contains information about the transmission of the system. The LED Transmission quality provides information about transmission quality of measured data from torque meter to torque control unit. The Sensor supply LED indicates the status of the torque sensor supply voltage. Alarm states Alarm values are displayed in the Alarm section. Red indicates that threshold is exceeded. Alarms can be reset by pressing button. Alarm limits can be set in the Alarm settings menu. Measured data Below the alarm states the measured data of the different system inputs Torque input 1, Torque input 2 3, Acceleration input 1, Speed input 1, Power supply torque sensor, Power supply controller and torque sensor Temperature are displayed numerical. Note Signals are not displayed in real-time. This may lead to delayed representations. Important Check the supply voltage and the orientation between torque sensor and stator-antenna to guarantee an optimal transmission quality. A B C Optimal (green) Okay (yellow) Bad (red) Transmitting (green) No Transmitting (gray) Value below Threshold (green) Value above Threshold (red) 3 Depending on the configuration of the current system DF Series Manual Version /60

25 5.3 Newdata In the case that another torque meter is connected, the adjusted values of the torque meter and the TCU IV are compared. If the values are different following dialog appears: By pressing the button, the values of the torque meter are transferred to the TCU IV. The outputs are adjusted accordingly. DF Series Manual Version /60

26 5.4 Power supply In the menu Power supply the supply voltage of the torque sensor will be adjusted. The power-switch activates and deactivates the power supply. On activation the last adjusted voltagevalue will be reactivated. Because the inductively transmitted power depends on the gap between torque sensor and stator-antenna the supply voltage has to be readjusted after change of position. The optimal supply voltage of the torque sensor is 9.5 V +/- 0.5 V. There are 2 methods for adjusting: 1. By pressing the button, the optimal supply voltage is automatically set. 2. The torque sensor voltage is set manually with the slider. Changes are applied in realtime. The further the slider is moved to the right, the higher the torque sensor supply voltage gets. In the following section, the influence of the torque sensor voltage to the signal quality is shown: Sensor voltage LED Sensor supply Description 9,5 V ± 0,5 V Green Optimal supply voltage 9,5 V ± 1,0 V Yellow Supply voltage is ok. Possibly interrupted transmission, if the supply voltage vary to much during the operation of the test bench 9,5 V ± > 1,0 V Red Poor supply voltage. Possibly interrupted transmission, possibly invalid measurement values Important The optimal torque sensor supply voltage should be at 9.5V. Power supply will be deactivated and set back to zero, if a critically value is adjusted, in order to prevent damage of inductive power supply components. DF Series Manual Version /60

27 5.5 Alarm settings Alarm thresholds for speed 4, acceleration 1 and torque can be adjusted. Torque input limit An alarm for the torque signal can be set. Alarm is triggered when threshold is exceeded. In dual range systems only the large measurement range 1 is observed. Speed input limit 1 An alarm for the speed signal can be set. Alarm is triggered when threshold is exceeded. Acceleration input limit 1 An alarm for the acceleration signal can be set. Alarm is triggered when threshold is exceeded. 4 Depending on the configuration of the current system DF Series Manual Version /60

28 5.6 Torquemeter Important Output switch 5 Improper values can falsify measurements or in worst case damage the measurement device. Proper values can be found in the test report. Output signals can be swapped. The output swap affects the following outputs: Effects of the output swap Output Website output Frequency output 1 Analog output (voltage) 1(*) Analog output (current) 1(*) CAN output 1 State Swapped Swapped Swapped Not swapped Not swapped (*) Only output 1 and output 2 Input settings Rated torque and sensitivity of the measurement system can as well as Torque input 1 and Torque input 2 1 be adjusted. 5 Depending on the configuration of the current system DF Series Manual Version /60

29 5.7 Measuring 1 The Measuring Menu appears if the system measures acceleration. Data input is performed as described in the previous chapter. DF Series Manual Version /60

30 5.8 Analog settings Voltage 6 range of analog outputs can be adjusted. Current 1 range of analog outputs can be adjusted. Output calibration Outputs must not be calibrated by an untrained user. Incorrect values can falsify the measurement. Outputs are calibrated at the factory and usually do not need to be recalibrated. 6 Depending on the configuration of the current system DF Series Manual Version /60

31 5.9 Frequency settings Diverse output ranges can be set in the menu item Frequency. Output 1 to 2 1 can be configured. Output calibration Outputs must not be calibrated by an untrained user. Incorrect values can falsify the measurement. Outputs are calibrated at the factory and usually do not need to be recalibrated. For further information please contact our support Filter settings The filter-settings influences the input signal. The filter is a digital IIR filter 1st order and is related to the torque input channels. For each input channel, the filter can be activated and the cut-off frequency can be set in the corresponding dropdown-box. The following cut-off frequencies between 1 Hz and 4000 Hz are supported: 1 Hz, 10 Hz, 50 Hz, 100 Hz, 150 Hz, 250 Hz, 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz. The button is clicked to save the settings. DF Series Manual Version /60

32 5.11 CAN settings CAN communication can be configured in the CAN menu. Scaling factor Received torque values need to be divided by the scale factor manually by the user. DF Series Manual Version /60

33 CAN state CAN transmission is enabled and disabled by toggling the button. The CAN State tab also contains information about the current state of the CAN bus. The different states are explained in the following sections. MODULE_ACTIVE: The CAN bus is working without any significant problems. The receive error counter (RX) and the transmit error counter (TX) are < 128. MODULE_PASSIV: The CAN bus works, however, a transmission or reception error occurred. TX or RX is > 127. In case that no more errors occurred, the counters are decremented and the status changes to MODULE_ACTIVE. Otherwise, the bus should be checked. BUS_OFF: The CAN module has been disconnected due to many transmission errors (TX > 255).Check the CAN settings and perform a CAN reset. INIT_ERROR: The CAN module cannot connect to the CAN bus. Check the CAN settings and perform a CAN reset. NOTE: CAN State can be reset by switching the output off and on again. DF Series Manual Version /60

34 CAN configuration The general CAN transmission can be configured. Selected values need to fit the values of the current receiver system. Baud (250kbit, 500kbit, 1Mbit) Transmit interval (between 1 and 1000 ms) Data format (Intel, Motorola) Identifier-Length (11 Bit, 29 Bit) Send configuration DF Series Manual Version /60

35 CAN messages are formatted (dependent on configurations) in the following way: Intel Data byte 0-3 Data byte 4-7 Identifier D0 D1 D2 D3 D4 D5 D6 D7 CAN-Identifier Torque 1 x Factor Torque 2 x Factor CAN-Identifier Speed 0 Motorola Identifier D3 D2 D1 D0 D7 D6 D5 D4 CAN-Identifier Torque 1 x Factor Torque 2 x Factor CAN-Identifier Speed 0 DF Series Manual Version /60

36 Four CAN messages at most can be configured. CAN Messages can be enabled and disabled. Messages one, two and three can be manually chosen and adjusted. The fourth message cannot be configured. It is reserved for watchdog and state and the transmit interval is fixed at 1000ms. Receive configuration The receiving identifier for CAN message can be chosen. The following CAN messages can be received: Messages Type Hex Dec Zero 0x4B Test signal (on) 0x4B Test signal (off) 0x4B MD1/MD2 0x4B MD2/MD1 0x4B State reset 0x4BB 1211 Request state 0x4BC 1212 Power supply (off) 0x Power supply (on) 0x Alarm reset 0x Request Ethernet settings 0xD The command must be included in the first 4 bytes [data bytes 0-3]. While receiving, distinction is made between Motorola and Intel. A response message is sent if a message is successfully received. The response massage is formatted in the following way: Response message Identifier Data byte [0-3] Data byte [4-7] receive identifier +1 last command state DF Series Manual Version /60

37 GENERAL STATES MEASUREMENT STATES ERROR STATES 5.12 State The status word is a 16-bit long data word, and is structured in the following way: STATE DESCRIPTION Bit alarm rx aborted transmission 15 alarm md exceeded the torque threshold 14 alarm n exceeded the speed threshold 13 alarm acc exceeded the acceleration threshold 12 signal quality poor signal quality 11 current error shutdown due overcurrent 10 current warning excessive current. current error in 4 minutes md2/md1 channel switch is active 8 9 zero zero adjustment was performed 7 test mode torque sensor test signal is on 6 test mode TCU test signal is on 5 - reserved 4 - reserved 3 - reserved 2 - reserved 1 power power supply is active 0 DF Series Manual Version /60

38 5.13 Ethernet settings Relevant adjustments for embedded measurement system in the intranet can be configured. Important Improper settings can break the device. In some cases the device cannot be reconfigured! In that case the torque control unit must be reprogrammed in factory. Administration must be consulted before configuring to get the proper settings. If the network settings of the TCU have been forgotten, the settings can be queries via the following CAN command: Messages Type Hex Dec Request Ethernet settings 0xD The response of the TCU has the following structure: Type IP Address Subnet Mask Byte i Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Content (HEX) Result (DEC) AC FF FF FF DF Series Manual Version /60

39 5.14 General settings A password and a custom name for the measurement system can be adjusted. Following characteristics must be fulfilled: Total length between 4 and 8 signs At least one upper-case letter At least one lower-case letter At least one digit Important Write down your password and keep it in a safe place. The password cannot be set back to default! DF Series Manual Version /60

40 5.15 Service page The up to date firmware version of the device and manufacturer s contact details can be found on the Service page. For service purposes, it s also possible to export a list of system parameters. DF Series Manual Version /60

41 6 Technical specs 6.1 Pinallocations 6.2 X770 Power supply / Frequency output 12-pin connector, type M23 Pin Signal Description Cable color (cable optional) Cross- Section in mm 1 F2_out- * 1 Frequency output ch. 2 RS422 White 0,25 2 F2_out+ * 1 Brown 0,25 3 N2_out+ * 1 Speed pulses output track 2 Gray 0,25 4 N2_out- * 1 RS422 Pink 0,25 5 N1_out+ * 1 Speed pulses output track 1 Blue 0,25 6 N1_out- * 1 RS422 Red 0,25 7 F1_out- Frequency output ch. 1 RS422 Yellow 0,25 8 F1_out+ Green 0,25 9 Aux_in Not used TTL 3.3 or TTL 5.0 White 0,5 10 Power+ Supply voltage Green 0,5 11 Power V / 1 A Yellow 0,5 12 Digital GND Ground connection of digital signals Brown 0,5 DF Series Manual Version /60

42 6.3 X771 Analogue / CAN / Alarm / Input 16-pin connector, type M23 1 Test_in Activate pos. full range of all outputs White 0,25 TTL 3.3 or TTL Zero_in Zero balance input TTL 3.3 or TTL Brown 0, Digital GND Ground connection of digital signals Green 0,25 4 Digital GND Yellow 0,25 5 CAN_H CAN HIGH connection Grey 0,25 6 CAN_L CAN LOW connection Pink 0,25 7 An4_out * 1 Galvanic isolated analog voltage output Blue 0,25 8 An2_out * 1 Galvanic isolated analog voltage output Red 0,25 9 An3_out * 1 Galvanic isolated analog voltage output Black 0,25 10 An1_out * 1 Galvanic isolated analog voltage output Purple 0,25 11 Alarm MD_out Alarm torque limit open-collector Grey/Pink 0,25 12 Analog GND Ground connection of analog signals Red/Blue 0,25 13 Alarm N_out Alarm speed limit open-collector White/Green 0,25 14 Alarm Rx_out Alarm receiving limit open-collector Brown/Green 0,25 15 Alarm Reset_in Reset all alarms TTL 3.3 or TTL 5.0 White/Yellow 0,25 16 IP Reset_in Coming soon Yellow/Brown 0,25 DF Series Manual Version /60

43 6.4 X772 Ethernet Can be connect with a standard Kat 5e cable for diagnostics or setup. For permanent installation inside the teststand use the special connector. Hummel - 7R X773 Central cable 15-pin connector, type M16 not for external periphery Pin Signal Description Cable color Cross-Section in mm / typ A Power+ Supply voltage White 0,5 / straight B Power- * 2 Brown 0,5 / straight C 7V-Power+ Green 0,5 / straight 1 Data-in+ Digital rotor data LVDS White 0,25 / twisted 2 Data-in- Brown 0,25 / twisted 3 7V-Power- * 2 Supply voltage (Reserved) NC 0,25 / twisted 4 N2- Speed-pulses track 2 Green 0,25 / twisted 5 N2+ Yellow 0,25 / twisted 6 N1- Speed-pulses track 1 Grey 0,25 / twisted 7 N1+ Pink 0,25 / twisted 8 PICUP Frequency pic up NC NC for analog systems (Reserved) 9 PICLVOUT+ System diagnostic (Reserved) NC NC 10 PICLVOUT- NC NC 11 PICLVIN+ NC NC 12 PICLVIN- NC NC * 1 Optional depending on the configuration of the system * 2 Pin B and Pin 3 are connected together in the circuit-board of the stator-antenna The following applies to double channel systems: Channel 1 corresponds to the measuring channel with the lower rated torque. Channel 2 corresponds to the measuring channel with the higher rated torque. DF Series Manual Version /60

44 6.6 General technical data Type DF1S DF2S DF3S DF4S DF5S Single Range Operation Rated Torque Mn nom Nm 1) 50 2) 100 3) 200 4) (500) Measuring range % of Mn nom 120 Accuracy class % ) (200) 2) 500 3) ) (1000) 2) ) ) ) 5000 Nominal speed rpm Rel. standard deviation % FSO 0.03 of repeatability Overload rating % 300 Temperature influence on zero point TK0 Temperature influence on nominal value TKC Signal span frequency output Signal span voltage output Signal span current output (option) Rated Temperature C Range Zero point stability at % FSO 0.03 reference temperature (48h) Operating temperature C 0 85 range Measurement frequency khz 3 range, -3dB, at zero frequency of 60kHz Protection Class IP 54 % 0.05 FSO/10 K % 0.05 FSO/10 K khz 10 ± 5 60 ± ± ± 120 V 0 ± 5 0 ± 10 2,5 ± 2,5 5 ± 5 ma 12 ± 8 1) (5000) 2) DF Series Manual Version /60

45 Type DF1S DF2S DF3S DF4 S DF5S Dual Range Operation Smallest second range 1:5 Accuracy Class for each range Overload Rating % of high range 6.7 High resolution speed encoder option Type DF1S DF2S DF3S DF4S DF5S Measurement principle Magnetized speed encoder with high resolution sensor head Output signal V 2 square wave signals 90 degree phase shifted, 5V (RS422) Nominal pulses per ppr revolution Minimum pulse number ppr (option) Maximum pulse number ppr (option) Reference Pulse on request Maximum counting rpm speed Maximum allowable rpm speed Cyclic error arc sec ± 30 Max. counting frequency khz 8 Max. axial displacement mm 1 between encoder and sensor Airgap Encoder Sensor mm 0,1-1 DF Series Manual Version /60

46 6.8 Mechanical data Ty pe DF1 DF2 DF3 DF4 DF5 Maximum rated torque Alternating torque Nm 1) 50 2) 100 3) 200 4) 500 Nm 1) 200 2) 500 3) ) ) ) 3000 equal selected maximum rated torque 1) ) ) ) Torsional stiffness Torsional angle Radial stiffness Axial stiffness Max. bending moment Radial load limit at run out error of 0,02mm Axial load limit knm/rad 1) 115 2) 177 3) 177 4) 272 1) 0,02 2) 0,03 3) 0,06 4) 0,11 kn/mm 1) 59,3 2) 82,1 3) 82,1 4) 119 kn/mm 1) 254 2) 331 3) 331 4) 456 Nm 1) 41 2) 57 3) 57 4) 83 kn 1) ) ) ) 2372 kn 1) 8 2) 10 3) 10 4) 14 Mass kg 1) 1,4 2) 1,4 3) 1,4 4) 1,4 1) 431 2) 391 3) 658 1) 0,03 2) 0,07 3) 0,09 1) 168 2) 156 3) 245 1) 530 2) 509 3) 705 1) 127 2) 119 3) 273 1) ) ) ) 16 2) 15 3) 21 1) 1,8 2) 1,8 3) 1,9 1) ) ) ) 0,05 2) 0,07 3) 0,07 1) 231 2) 374 3) 511 1) 497 2) 711 3) 914 1) 180 2) 292 3) 399 1) ) ) ) 15 2) 22 3) 28 1) 2,9 2) 3 3) 3 1) ) ) 0,06 2) 0,06 1) 534 2) 659 1) 686 2) 816 1) 427 2) 527 1) ) ) 21 2) 25 1) 4,35 2) 4,4 1) ) ) 0,05 2) 0,07 1) 559 2) 930 1) 517 2) 982 1) 537 2) 892 1) ) ) 16 2) 30 1) 7,7 2) 8 DF Series Manual Version /60

47 Inertia kgm² 1) 0, ) 0, ) 0, ) 0,00202 Balancing Q 2.5 class 1) 0, ) 0, ) 0, ) 0,0095 2) 0,0095 3) 0,0096 1) 0,0197 2) 0,0197 1) 0,057 2) 0,052 Mechanical Shock (EN ) Vibration Loads (EN ) Quantity n 1000 Frequency range Hz Duration ms 3 Duration Hz 2.5 Acceleration m/s² 650 Acceleration m/s² Single sided clutch device COUPLING ON OUTPUT SIDE Type DF1CR DF2CR DF3CR DF4CR DF5CR Rated torque (nominal) Nm 1) 50 2) 100 3) 200 4) 450 Nominal Speed rpm 1) ) ) ) ) (200) 2) 500 3) ) ) ) ) ) ) ) ) ) ) ) (5000) 2) ) ) 5600 input output DF Series Manual Version /60

48 6.8.2 Dimension rotor DF standard type [mm] Type Nominal rated torque DF1S 50/ 100 / 200/ (500) Nm ØD1 without speed encoder ØD1 with speed encoder ØD2 B B1 B DF2S (200)/ 500 / 1000 Nm DF3S (1000)/ 2000/ 3000) Nm DF4S 4/ 5 knm DF5S (5)/ 10 knm DF Series Manual Version /60

49 Type Nominal rated torque ØC T1 T2 PCD 1 N PCD 2 DF1S 50/ 100 / 200/ (500) Nm 57 H6/ g / Ø9 6x 84 / M8 DF2S (200)/ 500 / 1000 Nm 75 H6/ g ,5 / Ø11 8x 101,5 / M10 DF3S (1000)/ 2000 / 3000 Nm 90 H6/ g / Ø13 8x 130 / M12 DF4S 4/ 5 knm 11 0 H6/ g5 DF5S (5)/ 10 knm 14 0 H6/ g ,5 /Ø / Ø17 8x 8x 155,5 / M / M16 Note Dimension will change with adapted couplings DF Series Manual Version /60

50 6.8.3 Dimension stator DF Series Manual Version /60

51 6.8.4 Dimension TCUIV Dimension with couplings DF Series Manual Version /60

52 DF Series Manual Version /60

53 DF Series Manual Version /60

54 Type Rated torque (Nm) DF1CR 50/100 /200/ (450) DF2CR (200)/ 500 Max speed (rpm) L (mm) D1 (without speed encoder) D1 (with speed encoder) C1 (mm) Ø101 Ø107 Ø57 H Ø122 Ø128 Ø75 H6 DF2CR Ø122 Ø128 Ø75 H6 DF3CR (1000)/ Ø152 Ø158 Ø H6 DF3CR Ø152 Ø158 Ø90 H6 DF4CR Ø181 Ø187 Ø110 H6 DF4CR Ø181 Ø187 Ø110 H6 DF5CR (5000) Ø224 Ø230 Ø140 H6 DF5CR Ø224 Ø230 Ø140 H6 T1 (m m) PCD1 (mm, quantity, drill hole) B1 (m m) 4.2 Ø84 6x Ø Ø10 1,5 4.2 Ø10 1,5 4.2 Ø Ø Ø15 5,5 4.2 Ø15 5,5 4.2 Ø Ø19 6 8x 8x 8x 8x 8x 8x 8x 8x Ø1 1 Ø1 1 Ø1 3,5 Ø1 3,5 Ø1 5,5 Ø1 5,5 Ø1 7,5 Ø1 7, DF Series Manual Version /60

55 Type Rated torque (Nm) D2 (mm) C2 (mm) C3 (mm) T2 (mm) B2 (mm) PCD2 (mm, quantity, thread size) k a DF1CR 50/ 100 /200/ (450) DF2CR (200)/ 500 Ø136 Ø75 h7 Ø148 Ø85 h7 DF2CR 1000 Ø166 Ø95 h7 DF3CR (1000)/ Ø201 Ø h7 DF3CR 3000 Ø223 Ø130 h7 DF4CR 4000 Ø223 Ø130 h7 DF4CR 5000 Ø275 Ø160 h7 DF5CR (5000) Ø275 Ø160 h7 DF5CR Ø315 Ø170 h7 Ø126 h9 Ø138 h9 Ø156 h9 Ø191 h9 Ø213 h9 Ø213 h9 Ø265 h9 Ø265 h9 Ø305 h Ø114 4 x 3 M6 22, Ø123 6 x 3 M Ø140 6 x 3 M Ø172 6 x 3 M Ø193 6 x 3 M Ø193 6 x 3 M Ø239 6 x 3 M Ø239 6 x 3 M Ø275 6 x 3 M DF Series Manual Version /60

56 6.8.6 Torque and acceleration Specification Acceleration Sensor Range g ±12g ±25g ±50g ±100g ±200g ±400g Frequency Hz Response Max. Mechanical g Shock Non- Linearity % of span Available Torque Ranges combined with Acceleration Measurement DF1S Nm 50 / 100 DF2S Nm (200) / 500 / 1000 DF3S Nm (1000) / 2000 / 3000 DF4S Nm 4000 / 5000 DF5S Nm (5000) / Specification Acceleration Sensor Output Signal span frequency output khz 10 ± 5 60 ± ± ± 120 Signal span voltage output V 0 ± 5 0 ± 10 2,5 ± 2,5 5 ± 5 Measurement frequency range, -3dB, at zero frequency of 60kHz khz 3 DF Series Manual Version /60

57 DF Series Manual Version /60

58 DF Series Manual Version /60

59 DF Series Manual Version /60

60 Want to learn more about our products, solutions and services in the fields of measurement systems, vehicle equipment and actuators? Then please call us under +49 (0) or us at Your personal ATESTEO contact is always at your disposal. Konrad-Zuse-Str Alsdorf T +49 (0) F +49 (0) info@atesteo.com Art. No DF Series Manual Version /60

DF Series Manual Version /06

DF Series Manual Version /06 DF Series Manual DF Series Manual Version 1.7 2017/06 Konrad-Zuse-Str. 3 52477 Alsdorf T +49 (0) 2404 9870-0 F +49 (0) 2404 9870-59 info@atesteo.com DF Series Manual Version 1.7 2017/06 2/48 Inhalt 1 Introduction...

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P n n n n n Compact design: 59 mm mounting depth for single or multiturn Aids for start up and operation: diagnostic LED, preset key with optical response Parameterization: Resolution, code type, direction,

More information

Absolute encoders multiturn

Absolute encoders multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANopenift interface and optical sensor technology are the right encoders for all CANopen or CANopenift applications. With a maximum resolution

More information

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface O P E R A T I O N M A N U A L Version 01/05 RF-Reader Stand-alone-Reader Leser 2plus with RS-232 interface Important! Read by all means! To maintain the perfect shipping conditions and to ensure safe operation

More information

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads Product Information RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads May 2014 RIQ 425 Absolute rotary encoders Synchro flange 01C Solid shaft for separate shaft

More information

GFT channel Time Interval Meter

GFT channel Time Interval Meter Key Features Five-channel Time-Interval Meter: One Start and four Stops - 13 picosecond resolution - < 50 picosecond RMS jitter - > 100 second range - 10 MHz sample rate per channel Common GATE input Input

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. output 25 bit, Gray-coded clock rate: 62.5 KHz 1 MHz Single or multiturn, length

More information

Revision 1.2d

Revision 1.2d Specifications subject to change without notice 0 of 16 Universal Encoder Checker Universal Encoder Checker...1 Description...2 Components...2 Encoder Checker and Adapter Connections...2 Warning: High

More information

MICROMASTER Encoder Module

MICROMASTER Encoder Module MICROMASTER Encoder Module Operating Instructions Issue 01/02 User Documentation Foreword Issue 01/02 1 Foreword Qualified Personnel For the purpose of this Instruction Manual and product labels, a Qualified

More information

SAT IF distribution system

SAT IF distribution system 7. Technical specifications Type cs43 RF input frequency range pr. 50-350 MHz inputs number 4 level pr. 55...88 dbµv 60...93 dbµv symbol rate 3 45 Ms/s return loss/impedance > 0 db/75 Ω LNB powering/control

More information

EZ Encoder : Optical Incremental (P Series)

EZ Encoder : Optical Incremental (P Series) 1. Introduction Our EZ Encoders effectively eliminate multiple encoder part numbers by bringing intelligence and security to the design. A four-digit LED display with two push-buttons enables the user

More information

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff Ocean Sensor Systems, Inc. Wave Staff, OSSI-010-002F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff General Description The OSSI-010-002E Wave Staff is a water level sensor that

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

VIDEO GRABBER. DisplayPort. User Manual

VIDEO GRABBER. DisplayPort. User Manual VIDEO GRABBER DisplayPort User Manual Version Date Description Author 1.0 2016.03.02 New document MM 1.1 2016.11.02 Revised to match 1.5 device firmware version MM 1.2 2019.11.28 Drawings changes MM 2

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25) Appendices 1 (25) Project designation R5 RIC Document title CONTENTS 2 (25) 1 References... 4 2 Dimensions... 5 3 Connectors... 6 3.1 Power input... 6 3.2 Video I... 6 3.3 Video Q... 6 3.4 Sync... 6 3.5

More information

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Digital Video Recorder

Digital Video Recorder Digital Video Recorder Quick Operation Guide UD.6L0202B0067A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

IP LIVE PRODUCTION UNIT NXL-IP55

IP LIVE PRODUCTION UNIT NXL-IP55 IP LIVE PRODUCTION UNIT NXL-IP55 OPERATION MANUAL 1st Edition (Revised 2) [English] Table of Contents Overview...3 Features... 3 Transmittable Signals... 3 Supported Networks... 3 System Configuration

More information

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX Description This Ethernet Switch Module has been designed with 4x10/100Base-TX ports and 1x100Base-FX fiber optic port for the interconnection

More information

-TECH DIGITAL. Explore The High DefinitionWorld. Website: Hot Line: [US] USER MANUAL

-TECH DIGITAL. Explore The High DefinitionWorld. Website:  Hot Line: [US] USER MANUAL -TECH DIGITAL Explore The High DefinitionWorld Website: www.jtechdigital.com Hot Line: 1-888-610-2818[US] USER MANUAL J-Tech Digital ProAV H.264 Encoder/Decoder Many to Many HDMI Extender RoHS 1 Operating

More information

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach NEW DRS: Incremental encoders, number of lines and zero pulse width freely programmable DRS: s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide DS-7200HVI/HFI-SH Series DVR Quick Operation Guide UD.6L0202B0019A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is

More information

Smart-Encoder : Optical Incremental

Smart-Encoder : Optical Incremental 1. Introduction The Smart-Encoder effectively eliminates multiple encoder part numbers by bringing intelligence and security to its design. In seconds, a four-digit LED display with two push-buttons enables

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

Type SCH94FO. Type SCH94FO. Description

Type SCH94FO. Type SCH94FO. Description Type SCH94FO Hollow Shaft Fiber Optic Encoder - Ø 94 mm Dual Output Option (Digital & Fiber Optic) Fiber Optic Transmission up to 2,000 meters (~ 1.25 miles) No Degradation of Encoder Signal from Electrical

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement

More information

Video Server SED-2100R/S. Quick Installation Guide

Video Server SED-2100R/S. Quick Installation Guide Video Server SED-2100R/S Quick Installation Guide Feb.10,2006 1 1 Getting Started 1.1 PACKAGE CONTENTS SED-2100 Warranty Card Software CD Hook up & Screws Terminal Blocks for Power & DI/O Power Adaptor

More information

User Manual V2.6. Omniksol WIFIKIT User Manual. Omnik New Energy Co., Ltd.

User Manual V2.6. Omniksol WIFIKIT User Manual. Omnik New Energy Co., Ltd. User Manual V2.6 Omniksol WIFIKIT User Manual Omnik New Energy Co., Ltd. Overview of WIFIKIT Function Omniksol-WIFIKIT is developed by Omnik as an external communication monitoring device, which integrates

More information

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 Operating Instruction

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 Operating Instruction H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 Operating Instruction 1 Introduction This HDMI over IP Extender use the advanced H.264 as the compression type, which makes it occupy lower

More information

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/ 11/6/2009 www.elber.com elber@elber.it TCU/RCU RF Head Control Units User Manual Elber s.r.l.- Via Pontevecchio, 42W Phone +39-0185.35.13.33 16042 Carasco (GE) Italy Fax +39-0185.35.13.00 1 Sommario 2

More information

CI-218 / CI-303 / CI430

CI-218 / CI-303 / CI430 CI-218 / CI-303 / CI430 Network Camera User Manual English AREC Inc. All Rights Reserved 2017. l www.arec.com All information contained in this document is Proprietary Table of Contents 1. Overview 1.1

More information

DIRECT DRIVE ROTARY TABLES SRT SERIES

DIRECT DRIVE ROTARY TABLES SRT SERIES DIRECT DRIVE ROTARY TABLES SRT SERIES Key features: Direct drive Large center aperture Brushless motor design Precision bearing system Integrated position feedback Built-in thermal sensors ServoRing rotary

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual Field Test 2 Installation and operation manual OPDAQ 17.08.25 Installation and operation manual January 2016 How to get copies of OpDAQ technical publications: 53, St-Germain Ouest Rimouski, Québec Canada

More information

Modbus for SKF IMx and Analyst

Modbus for SKF IMx and Analyst User manual Modbus for SKF IMx and SKF @ptitude Analyst Part No. 32342700-EN Revision A WARNING! - Read this manual before using this product. Failure to follow the instructions and safety precautions

More information

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT) MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT) TECHNICAL DATA Measurement taken Position read sampling time (typical) Shock test DIN IEC68T2-27 Vibrations DIN

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator 20 Channel Digital Delay Generator Features of the 745T-20C: 20 Independent delay channels - 100 ps resolution - 25 ps rms jitter - 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every

More information

VNS2200 Amplifier & Controller Installation Guide

VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation 1. Determine the installation location for the VNS2200 device. Consider the following when determining the

More information

Magnetic Sensor - Incremental EHP

Magnetic Sensor - Incremental EHP small design: 12 x 13 x 35 mm stainless steel case resolution up to 0,5 μm; hysteresis ± 1μm pole pitch:1; 2 mm output signal: Digital (TTL-RS422) or analog (1 Vpp) direct connection to control / display

More information

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V 18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V With its characteristics of power stability whatever the load, very fast response time when pulsed (via external modulated signal), low ripple,

More information

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4... LVDT Inductive Position Transducer Series SM ø12 mm ranges 2...200 mm linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6 out: AC, 0...10 V, 0...5 V, 4...20 ma with external or integrated cable electronics repeatability

More information

BRIGHTLINK HDMI EXTENDER OVER ETHERNET - H METER MODEL: BL-EXT-IP-264

BRIGHTLINK HDMI EXTENDER OVER ETHERNET - H METER MODEL: BL-EXT-IP-264 BRIGHTLINK HDMI EXTENDER OVER ETHERNET - H.264-120 METER MODEL: BL-EXT-IP-264 Operating Instructions BRIGHTLINKAV.COM 1 Introduction This HDMI over IP Extender use the advanced H.264 as the compression

More information

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions For installation queries contact Customer Services +49 - (0)3 69 25-9 00 90 kundenservice@rutenbeck.de TCR IP 4 Operating instructions GB Device overview External buttons (for manual switching) Temperature

More information

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet Cable Extension Position Sensors with internal magnetic encoder Position Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

GFT Channel Digital Delay Generator

GFT Channel Digital Delay Generator Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Fours Triggers Three are repetitive from three

More information

Incremental Hollow Shaft Encoder

Incremental Hollow Shaft Encoder www.scancon.dk Incremental Hollow Shaft Encoder RMHF Introduction Mini hollow shaft encoder (blind end) mm diameter - up to 00 pulses/turn Up to 0000 counts Std. IP ( option; Ribbon cable +IDC connector

More information

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice.

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice. 1. Introduction 1.1 Overview The RFL VS800 CODEC enables high quality video transmission combined with voice and data over E1 (2.048Mbit/s), T1 (1.55Mbit/s) or Ethernet links. This provides an alternative

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

Dimming actuators GDA-4K KNX GDA-8K KNX

Dimming actuators GDA-4K KNX GDA-8K KNX Dimming actuators GDA-4K KNX GDA-8K KNX GDA-4K KNX 108394 GDA-8K KNX 108395 Updated: May-17 (Subject to changes) Page 1 of 67 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2 TECHNICAL DATA...

More information

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH Industriefunkuhren Technical Manual OEM Sync-Module FE1000 (IRIG-B) ENGLISH Version: 07.02-24.03.2014 2 / 19 FE1000 IRIG-B Synchronisation - V07.02 IMPORTANT NOTES Version Number (Firmware / Manual) THE

More information

User Manual K.M.E. Dante Module

User Manual K.M.E. Dante Module User Manual K.M.E. Dante Module Index 1. General Information regarding the K.M.E. Dante Module... 1 1.1 Stream Processing... 1 1.2 Recommended Setup Method... 1 1.3 Hints about Switches in a Dante network...

More information

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing. Product Data Electrical Data SST (Transmitter) SSR (Receiver) Supply voltage 18 30 V dc Max. Voltage ripple 15 % (within supply range) Current consumption 100 ma (RMS) 75 ma Digital - 100 ma Max. outputs

More information

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80 LWC Series LWC-80 Laser Wire Counting - Insensitive to outside light (due to interference filter, modulated light) - Visible laser spot (red light 670 nm) - Parameterisable through integrated switch and

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. SSI output 25 bit, Gray-coded SSI clock rate: 62.5 KHz 1 MHz Single or multiturn,

More information

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation... Li nearenc oder s wi t httlout put Us ermanual Index 1.0 Introduction..........................2 This Manual...........................2 2.0 Safety Summary......................3 Terms in this Manual....................3

More information

Technical data. General specifications. Indicators/operating means

Technical data. General specifications. Indicators/operating means Model Number Single head system Features Sensor head bidirectional and rotatable Function indicators visible from all directions Quick mounting bracket Selectable sound lobe width Programmable Diagrams

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

Electronic converter for level transmitters MT03L Instructions manual

Electronic converter for level transmitters MT03L Instructions manual Electronic converter for level transmitters MT03L Instructions manual R-MI-MT03L Rev.: 1 English version PREFACE Thank you for choosing the MT03L converter from MT03 series of Tecfluid S.A. This instruction

More information

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff Ocean Sensor Systems, Inc. Wave Staff III, OSSI-010-008 With 0-5V & RS232 Output and A Self Grounding Coaxial Staff General Description The OSSI-010-008 Wave Staff III is a water level sensor that combines

More information

DINOX&Digital&Video&Recorder&

DINOX&Digital&Video&Recorder& DINOX&Digital&Video&Recorder& & & & & & & & & & &&&Quick&Operation&Guide& UD.7L0X02B1228B01& Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact

More information

K-BUS Dimmer Module User manual-ver. 1

K-BUS Dimmer Module User manual-ver. 1 K-BUS Dimmer Module User manual-ver. 1 KA/D0103.1 KA/D0203.1 KA/D0403.1 Content 1. Introduction... 3 2. Technical Parameter... 3 3. Dimension and Connection Diagram... 4 3.1 KA/D0103.1... 4 3.2 KA/D0203.1...

More information

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151 Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

SC26 Magnetic Field Cancelling System

SC26 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

VIDEO ALARM VERIFICATION UNIT VIVER

VIDEO ALARM VERIFICATION UNIT VIVER VIDEO ALARM VERIFICATION UNIT VIVER viver_en 09/08 The VIVER module provides remote video alarm verification, based on image sequences transmitted from cameras installed in the protected facility. The

More information

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V 14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V With its characteristics of power stability independent of the load, very fast response time when pulsed (via external modulated signal), low

More information

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500 Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

Clamps, mounting plate EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles

Clamps, mounting plate EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles PRDS2 Magnetic Angle Encoder with Incremental Output Magnetic angle encoder 0-360 degrees in a flat housing with 36 mm dia. Measurement range 0 to 360 Protection class IP67 / IP69K Incremental encoder

More information

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder

More information

randomrhythm Bedienungsanleitung User Guide

randomrhythm Bedienungsanleitung User Guide randomrhythm Bedienungsanleitung User Guide EN Foreword Whether random really exists or is just an illusion, shall be discussed by philosophers and mathematicians. At VERMONA, we found a possibility to

More information

MT03A Electronic converter for flow rate transmitters

MT03A Electronic converter for flow rate transmitters Instructions manual MT03A Electronic converter for flow rate transmitters The art of measuring R-MI-MT03A Rev.: 0 English version PREFACE Thank you for choosing a Tecfluid S.A product. This instruction

More information

Outdoor Pixel-Router. User Guide

Outdoor Pixel-Router. User Guide Outdoor Pixel-Router User Guide 2017 Schnick-Schnack-Systems GmbH Version October 2017: All technical data and the weight and dimension information were carefully created errors reserved. Any colour deviations

More information

EZ Encoder : Optical Incremental

EZ Encoder : Optical Incremental 1. Introduction The EZ25 Encoder is a 2.5 incremental optical encoder, designed for optical shaft encoder motion control and precision sensor systems. Our ET7272 available models are short circuit proof

More information

Scanning System S-2100

Scanning System S-2100 2D laser measurement system The fastest 2D laser measurement system in the world 119 m range Scan rate >1 million points/sec 360 vertical field of view System description The PENTAX Scanning System S-2100

More information

T3316 IP QAM Modulator User Manual

T3316 IP QAM Modulator User Manual T3316 IP QAM Modulator User Manual SW Version: 1.02 HW version: 0.70.0.0 Web NMS version: 1.02 Intended Audience About This Manual This user manual has been written to help people who have to use, to integrate

More information

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T DM 4-2 T 4940280 DM 8-2 T 4940285 Updated: Jun-16 (Subject to change) Page 1 of 70 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2

More information

Standard RS232 RS ma

Standard RS232 RS ma 1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision

More information

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie. Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin,

More information

FS3. Quick Start Guide. Overview. FS3 Control

FS3. Quick Start Guide. Overview. FS3 Control FS3 Quick Start Guide Overview The new FS3 combines AJA's industry-proven frame synchronization with high-quality 4K up-conversion technology to seamlessly integrate SD and HD signals into 4K workflows.

More information

FRQM-2 Frequency Counter & RF Multimeter

FRQM-2 Frequency Counter & RF Multimeter FRQM-2 Frequency Counter & RF Multimeter Usage Instructions Firmware v2.09 Copyright 2007-2011 by ASPiSYS Ltd. Distributed by: ASPiSYS Ltd. P.O.Box 14386, Athens 11510 (http://www.aspisys.com) Tel. (+30)

More information

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features Description Page 1 of 8 The EM1 is a transmissive optical encoder module. This module is designed to detect rotary or linear position when used together with a codewheel or linear strip. The EM1 consists

More information

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator Z-IP Stream 004/008 User Guide and Installation Manual Four or Eight Input QAM Encoder / Modulator MPEG-2 / H.264 HD ENCODER with QAM /IP/ & ASI Outputs Contents Safety Precautions... 3 Package Contents...

More information

H m HDMI Wallplate Extender over IP

H m HDMI Wallplate Extender over IP Operating Instructions H.264 120m HDMI Wallplate Extender over IP Support PC Tool Control, POE, Audio Extraction at Receiver Operating Instruction 1 Introduction This HDMI Wallplate Extender over IP use

More information

HS-509 VIBRATION TRIP MODULE

HS-509 VIBRATION TRIP MODULE HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an

More information