TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

Size: px
Start display at page:

Download "TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4"

Transcription

1 TITLE SPECIFICATION FOR DANGER AND DATE: NOVEMBER 2006 PAGE: 1 OF 13 TABLE OF CONTENTS Page FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE S WARNING TAPE Material Size Thickness Colour CABLE TRENCH DANGER TAPE Material Size Thickness Colour and markings MARKING, PACKING AND DOCUMENTATION Marking Packing Documentation QUALITY ASSURANCE... 6 Annex A - Bibliography... 7 Annex B - Revision information... 8 Annex C Item No. 1 Warning tape SAP No

2 PAGE 2 OF 13 Item No. 1 Warning tape SAP No Item No. 2 Cable trench danger tape SAP No Annex D Stock Items... 13

3 PAGE 3 OF 13 FOREWORD Recommendations for corrections, additions or deletions should be addressed to the: Technology Services Manager City Power Johannesburg (Pty) Ltd P O Box Booysens 2016

4 PAGE 4 OF 13 INTRODUCTION To achieve standardisation and rationalisation, good quality PVC danger and warning tapes which shall be easily visible and resistant to deterioration shall be used. The cable trench danger tape shall be used to bring into attention the presence of cables in the proximity when excavating and the warning tape for cordoning off hazardous and dangerous areas. 1 SCOPE This specification covers City Power s requirements for cable trench danger and warning tapes. 2 NORMATIVE S The following documents contain provisions that through reference in the text constitute requirements of this specification. At the time of publication the editions indicated were valid. All standards and specifications are subject to revision and parties to agreements based on this specification are encouraged to investigate the possibility of applying the most recent editions of the documents listed below. SANS 1186: Symbolic safety signs. 3 WARNING TAPE 3.1 Material The tape shall be of a non-adhesive polyvinyl chloride (PVC) type. 3.2 Size The tape shall be provided in rolls of 500 m long X 90 mm wide. 3.3 Thickness The tape shall have a thickness of 100 µm. 3.4 Colour The chevron tape shall be white with non-fading red diagonal stripes The diagonal stripes shall be 53 mm wide at an angle of 45 0 apart to the edge of the tape The red diagonal stripes shall be spaced 75 mm along the edge of the tape.

5 PAGE 5 OF 13 4 CABLE TRENCH DANGER TAPE 4.1 Material The tape shall be of a non-adhesive polyvinyl chloride (PVC) type. 4.2 Size The tape shall be provided in rolls of 500 m long X 450 mm wide. 4.3 Thickness The tape shall have a thickness of 100 µm. 4.4 Colour and markings The tape shall be yellow with non-fading black printing The printing shall be suitably spaced and repeated every 1000 mm over the full length of the tape The printing shall be as follows: a) Electricity (danger) logo, sign WW7, as per SANS 1186, and lettering 12 mm high followed by the notice DANGER / GEVAAR / INGOZI, followed by. b) ELECTRIC CABLE / ELEKTRIESE KABEL in black lettering, 30 mm high. 5 MARKING, PACKING AND DOCUMENTATION 5.1 Marking The tape core shall be clearly and indelibly marked with the following: a) Brand name or trade mark. 5.2 Packing The tapes shall be individually packed, in acceptable plastic wrapping, so that they are adequately protected from damage during normal transit Each roll shall be supplied on a suitable reel which shall be sturdy and hard Catalogue number shall be marked on each roll City Power s SAP number shall be clearly shown on the label. 5.3 Documentation Documentation shall be submitted in a technical catalogue format The technical catalogue shall specify the sizes, dimensions, reference numbers, and if applicable, the complete range of other products and accessories available.

6 PAGE 6 OF 13 6 QUALITY ASSURANCE A quality management system shall be set up in order to assure the quality of the tapes during development, production, and installation. Guidance on the requirements for a quality management system may be found in the following standards: SANS ISO 9000, SANS ISO 9001, SANS ISO 9002, SANS ISO 9003 and SANS ISO The details shall be subject to agreement between the purchaser and supplier.

7 PAGE 7 OF 13 CP 62/442: CABLE MARKER TAB TAPE Annex A - Bibliography

8 PAGE 8 OF 13 Annex B - Revision information DATE. NO. NOTES Aug First issue Jan Second issue Basic editing Added study committee members Clause 4.2 Changed the width of the tape from 150mm to 450mm

9 PAGE 9 OF 13 Annex C Item No. 1 Warning tape SAP No Schedule A: Purchaser's specific requirements Schedule B: Guarantees and technical particulars of equipment offered Item Subclause of CP_TSSPEC_083 Description Schedule A Schedule B 1 Manufacturer xxxx Printing of stripes Colour of tape and stripe Non-fading ink White with red diagonal stripes Width of tape mm Length of tape m Width of stripe mm Distance between stripes mm Thickness of tape µm Markings comply Required Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

10 PAGE 10 OF 13 Item No. 1 Warning tape SAP No Deviation schedule Any deviations offered to this specification shall be listed below with reasons for deviation. In addition, evidence shall be provided that the proposed deviation will at least be more costeffective than that specified by City Power. Item Subclause of CP_TSSPEC_083 Proposed deviation Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

11 PAGE 11 OF 13 Annex C - Item No. 2 Cable trench danger tape SAP No Schedule A: Purchaser's specific requirements Schedule B: Guarantees and technical particulars of equipment offered Item Subclause of CP_TSSPEC_083 Description Schedule A Schedule B 1 Manufacturer xxxx Printing of letters Colour of tape, print and logo Non-fading ink Yellow with black printing Width of tape mm Length of tape m Width of letters mm Pitch of lettering mm Every one meter Thickness of tape µm Markings comply Required Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

12 PAGE 12 OF 13 Item No. 2 Cable trench danger tape SAP No Deviation schedule Any deviations offered to this specification shall be listed below with reasons for deviation. In addition, evidence shall be provided that the proposed deviation will at least be more costeffective than that specified by City Power. Item Subclause of CP_TSSPEC_083 Proposed deviation Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

13 PAGE 13 OF 13 Annex D Stock Items Material Group: CONT-TAPE Item SAP N o. SAP Short Description SAP Long Description TAPE DANGER YELLOW BLACK TAPE WARNING RED WHITE TAPE, DANGER, NON ADHESIVE, POLYVINYL CHLORIDE, 500M X 450MM, YELLOW WITH BLACK PRINT FOR WARNING AND CABLE MARKING PURPOSES, ITEM SPECIFICATION NO. CP_TSSPEC_083 TAPE, CHEVRON, NON ADHESIVE, POLYVINYL CHLORIDE, 500M X 90MM, RED AND WHITE FOR WARNING PURPOSE, ITEM SPECIFICATION NO. CP_TSSPEC_083

3WS(Cape Town/Secretariat)1

3WS(Cape Town/Secretariat)1 For IEC use only 3WS(Cape Town/Secretariat)1 2005-10-04 INTERNATIONAL ELECTROTECHNICAL COMMISSION Technical Committee No. 3: Information structures, documentation and graphical symbols Occurrence-related

More information

IndyGo Facility Upgrades Project 35671EE

IndyGo Facility Upgrades Project 35671EE SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Identification of power and control cables. 3. Identification for

More information

Signalling Cable Equivalent Sizes

Signalling Cable Equivalent Sizes Signalling Cable Equivalent Sizes Signatures removed from electronic version Submitted by... Jim Harper Nominated Responsible Manager Synopsis This Standard Authorises the use of cables to GS/ES 0872 as

More information

ISO/IEC INTERNATIONAL STANDARD. Information technology - 8 mm wide magnetic tape cartridge for information interchange - Helical scan recording

ISO/IEC INTERNATIONAL STANDARD. Information technology - 8 mm wide magnetic tape cartridge for information interchange - Helical scan recording INTERNATIONAL STANDARD ISO/IEC 9 First edition 993-07-5 Information technology - 8 mm wide magnetic tape cartridge for information interchange - Helical scan recording Technologies de I informa tion -

More information

Identification - electrical services

Identification - electrical services Identification - electrical services Aesthetic All live phase cable sheathing to be brown coloured and neutral phase cable sheathing to be blue coloured, all labelled L1, L2, L3 & N respectively in accordance

More information

Numerous cables one solution: Serpa cable organization

Numerous cables one solution: Serpa cable organization Serpa a brand of H. Hiendl GmbH & Co. KG Industriestraße 5 + 6 94327 Bogen, Germany Contact: Telephone +49 (0) 94 22/8518-0 info@serpa.de www.serpa.de H.Hiendl GmbH & Co.KG, Design: Gestaltungsbüro Schultes,

More information

Draft for Public Comment

Draft for Public Comment Draft for Public Comment Form 36 Version 6.1 DPC: 03/302646 DC Head Office 389 Chiswick High Road London W4 4AL Telephone: +44(0)20 8996 9000 Fax: +44(0)20 8996 7001 Date: 27 March 2003 Origin: National

More information

AES standard for audio connectors - Modified XLR-3 Connector for Digital Audio. Preview only

AES standard for audio connectors - Modified XLR-3 Connector for Digital Audio. Preview only Reaffirmed 2017 AES standard for audio connectors - Modified XLR-3 Connector for Digital Audio Published by Audio Engineering Society, Inc. Copyright 2011 by the Audio Engineering Society Abstract This

More information

PTS RABKA TRADE AND PRODUCTION COMPANY

PTS RABKA TRADE AND PRODUCTION COMPANY PTS RABKA TRADE AND PRODUCTION COMPANY The PTS Rabka Company is a manufacturer of top quality warning and warning-detection tapes for marking telecommunication, gas, sewage and energy systems. The PTS

More information

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0 Proposed SMPTE Standard for Television Date: TP Rev 0 SMPTE 424M-2005 SMPTE Technology Committee N 26 on File Management and Networking Technology SMPTE STANDARD- --- 3 Gb/s Signal/Data Serial

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61834-2 First edition 1998-08 Recording Helical-scan digital video cassette recording system using 6,35 mm magnetic tape for consumer use (525-60, 625-50, 1125-60 and 1250-50

More information

Guidelines for use of the Access to HE trademarks

Guidelines for use of the Access to HE trademarks Guidelines for use of the Access to HE trademarks September 2016 Introduction 1. The Access to Higher Education (HE) trademarks comprise the Access to HE logos and wordmarks. They act as a visual marker

More information

ISO/IEC INTERNATIONAL STANDARD

ISO/IEC INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 148 First edition 199-1-15 Information technology -,81 mm wide magnetic tape cartridge for information interchange - Helical scan recording - DATA/DAT-DC format using 60

More information

ISO/IEC INTERNATIONAL STANDARD

ISO/IEC INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 80 First edition 996-08-0 Information technology -,65 mm wide magnetic tape cartridge for information interchange - Helical scan recording - Data-D format Technologies de

More information

ETSI ES V1.1.1 ( )

ETSI ES V1.1.1 ( ) ES 202 319 V1.1.1 (2004-06) Standard Transmission and Multiplexing (TM); Passive optical components and cables; Optical fibre cables to be used for patchcord applications for single-mode optical fibre

More information

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 USER MANUAL European Models American Models 60/100/120 3/4/5 24/40/48 3/4/5 Read the instructions before using the machine. EN (Original Instruction) 9124097 / 1704 KEEP THIS USER MANUAL FOR FUTURE USE

More information

Preview only.

Preview only. AES49-2005 (r2010) AES standard for audio preservation and restoration - Magnetic tape - Care and handling practices for extended usage Published by Audio Engineering Society, Inc. Copyright 2005 by the

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62447-1 First edition 2007-06 Helical-scan compressed digital video cassette system using 6,35 mm magnetic tape Format D-12 Part 1: VTR specifications Commission Electrotechnique

More information

UHF RFID Tag Data Sheet LXMS21ACNP-184

UHF RFID Tag Data Sheet LXMS21ACNP-184 1. General descriptions is an innovative RFID module designed to operate in electronic products/applications. It incorporates an industry standard IC. [Features] -Small package design -Reflow SMT compatible

More information

Technical Data Sheet. Scotchlite Reflective Material Series 6100 High Gloss Trim Series 6200 High Gloss Film. Retroreflective Performance.

Technical Data Sheet. Scotchlite Reflective Material Series 6100 High Gloss Trim Series 6200 High Gloss Film. Retroreflective Performance. Technical Data Sheet 3 Scotchlite Reflective Material Series 6100 High Gloss Trim Series 6200 High Gloss Film Technical Data Sheet August 1999 Description 3M Scotchlite Reflective Material - High Gloss

More information

IEEE 383 Standard for Qualifying Electric Cables and Splices for. NPEC January 2015 Robert Konnik. Nuclear Facilities Preview II

IEEE 383 Standard for Qualifying Electric Cables and Splices for. NPEC January 2015 Robert Konnik. Nuclear Facilities Preview II IEEE 383 Standard for Qualifying Electric Cables and Splices for NPEC January 2015 Robert Konnik Nuclear Facilities Preview II IEEE 383 Background This standard provides guidance for developing a program

More information

case 5 temperature sensor cosine sensor sine sensor ground + 5V phase 2- phase 2+ phase 1- phase 1+

case 5 temperature sensor cosine sensor sine sensor ground + 5V phase 2- phase 2+ phase 1- phase 1+ Motor Cables Accessories Motor Cables Extension cables tailo for use with Norgren NP Linear Motors are available in two different versions; standard and high flex for the use in trailing chains or cable

More information

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:00 Date: 08.03.2010 SPECIFICATION OF 192F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-192/SM/MTY(F)-MFN-O9.1 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

ENGINEERING COMMITTEE

ENGINEERING COMMITTEE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 61 2012 Test Method for Jacket Web Separation NOTICE The Society of Cable Telecommunications Engineers (SCTE)

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION ISSUED : OCT. 02, 2006 PAGE : 1 OF 9 REV. : 1 TECHNICAL SPECIFICATION FOR GST 2006-043A LOOSE TUBE DRY CORE CABLE SINGLE JACKET/SINGLE ARMOR (SJSA CABLE) Prepared By : Oh-Heoung Kwon Engineer Optical Technical

More information

AS/NZS :2011

AS/NZS :2011 AS/NZS 62087.2.2:2011 Incorporating Amendment Nos 1 and 2 Australian/New Zealand Standard Power consumption of audio, video and related equipment Part 2.2: Minimum energy performance standards (MEPS) and

More information

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:01 Date: 07.10.06 SPECIFICATION OF 96F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-96/SM/MTY(F)-MFN-O6.3 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

CONSOLIDATED VERSION IEC Digital audio interface Part 3: Consumer applications. colour inside. Edition

CONSOLIDATED VERSION IEC Digital audio interface Part 3: Consumer applications. colour inside. Edition CONSOLIDATED VERSION IEC 60958-3 Edition 3.2 2015-06 colour inside Digital audio interface Part 3: Consumer applications INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 33.160.01 ISBN 978-2-8322-2760-2 Warning!

More information

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited MSF1000 MSF Radio Time Code Receiver User Manual Version 1.1 World Time Solutions World Time Solutions Limited COPYRIGHT 2011-2014 World Time Solutions Limited. All Rights Reserved. All information contained

More information

BML-M0 _-I -A _-... User's Guide

BML-M0 _-I -A _-... User's Guide BML-M0 _-I -A _-... User's Guide english www.balluff.com 1 Notes to the user 4 1.1 Validity 4 1.2 Symbols and conventions 4 1.3 Scope of delivery 4 2 Safety 5 2.1 Intended use 5 2.2 General safety notes

More information

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009 Medium Voltage 12/20 (24)kV NF C 33-226 cable system Xavier Brosse Luanda May 2009 1 Evolution of French standard for MV cables Late 70 s : NF C 33-223 Cable Standard in France result of the move from

More information

35PM-FCD-ST app-2e Sony Pictures Notes doc. Warning

35PM-FCD-ST app-2e Sony Pictures Notes doc. Warning WORKING DRAFT Interoperable Master Format Application #2 Extended Page 1 of 7 pages 35PM-FCD-ST-2067-21-app-2e-20130503-Sony Pictures Notes 6-5-13.doc Warning This document is not a SMPTE Standard. It

More information

MANUAL CABLE MARKING SYSTEM PMP-30 PUSH-IN CABLE MARKERS WITH HOLDERS

MANUAL CABLE MARKING SYSTEM PMP-30 PUSH-IN CABLE MARKERS WITH HOLDERS MANUAL CABLE MARKING SYSTEM Provides alternative manual systems for identifying cables, tubes, conduit, components and equipment. PMP push-in cable markers for use with PM transparent holders RMS and FMS

More information

Your friendly local supplier of:

Your friendly local supplier of: A family owned manufacturer of quality library supplies since 2001 Your friendly local supplier of: Book Covering Products Adhesive Printer Labels Lamina ng film & laminator service Adhesive tapes Security

More information

SMT Splice Tape Series. Increase Pick & Place Machine output by 5%-30% Use all components on the carrier tape. Reduce reel change downtime

SMT Splice Tape Series. Increase Pick & Place Machine output by 5%-30% Use all components on the carrier tape. Reduce reel change downtime SMT Splice Tape Series The Splice Tape is used for various industry,for all kinds of carrier tape. A fast, precise way to connect SMT component reels. Increase Pick & Place Machine output by 5%-30% Use

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60286-3 Fourth edition 2007-06 Packaging of components for automatic handling Part 3: Packaging of surface mount components on continuous tapes Commission Electrotechnique Internationale

More information

ISO/IEC INTERNATIONAL STANDARD. Information technology Data interchange on 12,7 mm, 384-track magnetic tape cartridges Ultrium-1 format

ISO/IEC INTERNATIONAL STANDARD. Information technology Data interchange on 12,7 mm, 384-track magnetic tape cartridges Ultrium-1 format INTERNATIONAL STANDARD ISO/IEC 22050 First edition 2002-10-01 Information technology Data interchange on 12,7 mm, 384-track magnetic tape cartridges Ultrium-1 format Technologies de l'information Échange

More information

American National Standard for Electric Lamps Double-Capped Fluorescent Lamps Dimensional and Electrical Characteristics

American National Standard for Electric Lamps Double-Capped Fluorescent Lamps Dimensional and Electrical Characteristics American National Standard for Electric Lamps Double-Capped Fluorescent Lamps Dimensional and Electrical Characteristics Secretariat: National Electrical Manufacturers Association Approved August 15, 2014

More information

ISO INTERNATIONAL STANDARD. Information and documentation Requirements for binding materials and methods used in the manufacture of books

ISO INTERNATIONAL STANDARD. Information and documentation Requirements for binding materials and methods used in the manufacture of books INTERNATIONAL STANDARD ISO 11800 First edition 1998-04-15 Information and documentation Requirements for binding materials and methods used in the manufacture of books Information et documentation Prescriptions

More information

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITHOUT METALLIC SCREEN

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITHOUT METALLIC SCREEN Engineering Specification Electrical Networks MESP 030000-02 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED Version: 1 Issued: March 2014 Owner: Electrical

More information

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014 Sumitomo Cable Specification SE-*RU Litepipe Ribbon Indoor Plenum Cable OFNP Rated Central Tube Cable with 12-432 Optical Fibers Issued: December 2014 78 Alexander Drive, Research Triangle Park, NC 27709

More information

Standards for the Format and Binding of a Thesis

Standards for the Format and Binding of a Thesis Purpose of Guidance The procedure sets out regulatory standards for the format and binding of postgraduate research theses to provide clarity and consistency. This applies to theses submitted for assessment

More information

ENGINEERING COMMITTEE

ENGINEERING COMMITTEE ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE 63 2015 Test Method for Voltage / Spark Test of Outer Jacket NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-28809-9 SOUTH AFRICAN NATIONAL STANDARD Set-top box decoder for free-to-air digital terrestrial television WARNING This standard references other documents normatively. Published by SABS

More information

STANDARDS AND INFORMATION DOCUMENTS

STANDARDS AND INFORMATION DOCUMENTS STANDARDS AND INFORMATION DOCUMENTS AES standard for forensic purposes Criteria for the authentication of analog audio tape recordings Users of this standard are encouraged to access http://www.aes.org/standards

More information

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION PART 1 - GENERAL 1.1 SUMMARY SCOPE SECTION 25170 TESTING, IDENTIFICATION AND ADMINISTRATION 1. This section includes the minimum requirements for the testing, certification administration and identification

More information

TENSIONED ELPRO CONCEPT Motorized projection screen for wall or ceiling installations

TENSIONED ELPRO CONCEPT Motorized projection screen for wall or ceiling installations Motorized projection screen for wall or ceiling installations Watch the video: Product specifications: Electrically operated projection screen 230 volt (50Hz) with a usage of no more than 0.53 Ampere (121.9

More information

Chicago Pneumatic Brand Identity Manual for Distributors

Chicago Pneumatic Brand Identity Manual for Distributors Chicago Pneumatic Brand Identity Manual for Distributors www.cp.com This manual is aimed at distributors with a valid Chicago Pneumatic agreement. Working with Chicago Pneumatic Chicago Pneumatic has worldwide

More information

Gear up for the future.

Gear up for the future. OptiC@ t5e Gear up for the future. OptiC@t 5e cables will take you there. Gear up for the future. Future-proof your home! The communication cable OptiC@t 5e is a combo of a four pair Cat5e and two bend-insensitive

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60921 Edition 2.1 2006-06 Edition 2:2004 consolidated with amendment 1:2006 Ballasts for tubular fluorescent lamps Performance requirements IEC 2006 Copyright - all rights reserved

More information

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor Part Number: Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor Product Description Four Cat 6 23 AW G solid bare copper conductors, bonded pair polyolefin Insulation, DATATUFF

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100

More information

Scotch Heavy Duty Vinyl Electrical Tape 22

Scotch Heavy Duty Vinyl Electrical Tape 22 Scotch Heavy Duty Vinyl Electrical Tape 22 Data Sheet July 2015 Description Agency Approvals & Self Certifications Scotch Heavy Duty Vinyl Electrical Tape 22 is a premium grade, 10-mil thick, vinyl insulating

More information

Graphic Protection Options Overlaminates and clears Product Bulletin

Graphic Protection Options Overlaminates and clears Product Bulletin 3M Europe, Effective March 2015 Graphic Protection Options Overlaminates and clears Product Bulletin Product Bulletin Products This Bulletin provides an overview of all 3M graphic protection options. All

More information

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited GPS000 GPS Time Receiver System User Manual Version. World Time Solutions World Time Solutions Limited COPYRIGHT 0-0 World Time Solutions Limited. All Rights Reserved. All information contained within

More information

User Manual MagniLink Mira

User Manual MagniLink Mira User Manual MagniLink Mira LVI Low Vision International Verkstadsgatan 5 Tel: +46 470 727700 E-mail: info@lvi.se 352 46 Växjö SWEDEN Fax: +46 470 727725 Internet: www.lvi.se CONTENTS 1. GENERAL INFORMATION...

More information

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) 2-3, Marunouchi 2-chome, Chiyoda-ku, Tokyo 100-8322, Japan No. FB-KL4001C for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) Aug 2014 1 1. General This specification describes

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 14 2016 Test Method for Hex Crimp Tool Verification/Calibration NOTICE The Society of Cable Telecommunications

More information

SDTV 1 DigitalSignal/Data - Serial Digital Interface

SDTV 1 DigitalSignal/Data - Serial Digital Interface SMPTE 2005 All rights reserved SMPTE Standard for Television Date: 2005-12 08 SMPTE 259M Revision of 259M - 1997 SMPTE Technology Committee N26 on File Management & Networking Technology TP Rev 1 SDTV

More information

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN 1.1 TECHNICAL DATA PRODUCT DESCRIPTION Screens made with the following projection fabrics: SOFT WHITE, MATT WHITE SOFT, SOFT WHITE TRANSOUND,

More information

GUIDANCE DOCUMENT No 9 ON THE APPLICATION OF THE DIRECTIVE ON THE SAFETY OF TOYS BOOKS

GUIDANCE DOCUMENT No 9 ON THE APPLICATION OF THE DIRECTIVE ON THE SAFETY OF TOYS BOOKS EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Single Market for Goods Internal Market and its International Dimension Last updated: 10/12/2013 GUIDANCE DOCUMENT No 9 ON THE APPLICATION

More information

Installation instructions Roxtec CM PE systems

Installation instructions Roxtec CM PE systems Safety information Roxtec recommends that all installations are performed without facility operation. Follow national regulations and installation codes. ny action affecting the routed service should be

More information

PJLink Specification and Handling Rules for Trademark and Logo

PJLink Specification and Handling Rules for Trademark and Logo Annex A PJLink Specification and Handling Rules for Trademark and Logo September 27, 2016 Japan Business Machine and Information System Industries Association (JBMIA) PJLink Specification and Handling

More information

Introduction. Introduction

Introduction. Introduction Introduction Introduction Note: In this user guide Pronto is used for both ProntoPro and Pronto remote controls. RFX6000 is compatible with TSU3000 and TSU6000. About the RFX6000 Most remote control systems

More information

Installation instructions Cable transit device Roxtec RS ES Ex

Installation instructions Cable transit device Roxtec RS ES Ex General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60958-1 Second edition 2004-03 Digital audio interface Part 1: General Reference number IEC 60958-1:2004(E) Publication numbering As from 1 January 1997 all IEC publications

More information

Installation instructions Roxtec RM PE B

Installation instructions Roxtec RM PE B Installation instructions Roxtec RM PE B Environmental side Termination/ interior side Pipe Cable screen/armor Layers Termination/ interior side Cable sheath Layers Environmental side Plastic film Conductive

More information

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1: Part Number: 7929A Cat 5e MSHA DataTuff, (4 pr) 24 AW G Solid BC, PO/PVC, Foil Shld, CMR, CMX-Outdoor Product Description Four Cat 5e 24 AW G Bonded-Pairs solid bare copper conductors, polyolefin insulation,

More information

Logo Usage Guide TUV AUSTRIA TURK. Guide for document designs Rev. 04 / GUI-001a Rev.4 /

Logo Usage Guide TUV AUSTRIA TURK. Guide for document designs Rev. 04 / GUI-001a Rev.4 / TUV AUSTRIA TURK Logo Usage Guide Guide for document designs Rev. 04 / 12.01.2018 www.tuvaustriaturk.com GUI-001a Rev.4 / 12.01.2018 Sayfa 1 / 14 Page 1 Contents Introduction... 3 Logo... 4 Important:

More information

Micro duct Cable with HDPE Sheath for Installation by Blowing

Micro duct Cable with HDPE Sheath for Installation by Blowing Optical Fiber Cable Technology Specification INTERNAL Optical Fiber Cable Specification Micro duct Cable with HDPE Sheath for Installation by Blowing GCYFY-12/24/36/48/72/96/144/288/432/576B1.3 V7.0 2018-3-20,CCopyright.

More information

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI 620 014. CONTROLS AND INSTRUMENTATION/FB DATA SHEET FOR MULTICORE, ARMOURED, CONTROL CABLE Project: Ennore Sez, 2 x 660 MW,

More information

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv INSTALLATION INSTRUCTION PEM1124ENG 2010-05 STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv ENGLISH 4 CORE 3+1 CORE 2/8 PEM1124ENG

More information

User Manual. Applications. See for more detailed information. Manual Version: Software Version: 2.03.

User Manual. Applications. See   for more detailed information. Manual Version: Software Version: 2.03. User Manual Applications Manual Version: 2.00 Software Version: 2.03 Language: English See www.idig-system.com for more detailed information. Safety Information: Magnets Use caution with the powerful magnets

More information

Installation instructions Roxtec RS ES Ex

Installation instructions Roxtec RS ES Ex General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61947-2 First edition 2001-09 Electronic projection Measurement and documentation of key performance criteria Part 2: Variable resolution projectors IEC 2001 Copyright - all

More information

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK J. Becker NEXANS BENELUX S.A. F. Musique ELECTRABEL S.A. ABSTRACT In order to tackle the deregulated market with confidence and in a realistic way,

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD IEC 61966-9 Second edition 2003-11 Multimedia systems and equipment Colour measurement and management Part 9: Digital cameras Systèmes et appareils multimédia Mesure et gestion de

More information

Installation instructions Roxtec RM ES B

Installation instructions Roxtec RM ES B Installation instructions Roxtec RM ES B Environmental side Termination/ interior side Pipe Cable screen/armor Layers Termination/ interior side Cable sheath Layers Environmental side Vertical screen Plastic

More information

AWT150C/AWT150CS/ AWT151C CCD Camera

AWT150C/AWT150CS/ AWT151C CCD Camera AWT150C/AWT150CS/ AWT151C CCD Camera ISSUED OCTOBER 2018 WARNING Failure to follow all instructions and safety precautions in this manual, in the vehicle and body manufacturers' manuals and on the safety

More information

Touch Panel RGB LED Controller Part No. touch-panel-rgb

Touch Panel RGB LED Controller Part No. touch-panel-rgb 11235 West Bernardo Court, Suite 102 San Diego, CA 92127 888-880-1880 Fax: 707-281-0567 EnvironmentalLights.com Touch Panel RGB LED Controller Part No. touch-panel-rgb The Touch Panel RGB LED Controller

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61966-9 Second edition 2003-11 Multimedia systems and equipment Colour measurement and management Part 9: Digital cameras Systèmes et appareils multimédia Mesure et gestion de

More information

3M Knifeless Tape. Finish Line Perf Line Bridge Line Design Line Tri Line Precision Line PPF Line. Product Description. Commercial Solutions Division

3M Knifeless Tape. Finish Line Perf Line Bridge Line Design Line Tri Line Precision Line PPF Line. Product Description. Commercial Solutions Division Effective January 2017 Commercial Solutions Division 3M Knifeless Tape Finish Line Perf Line Bridge Line Design Line Tri Line Precision Line PPF Line Product Description 3M Knifeless Tapes are filament

More information

01. Who is eligible to use the RICS Registered Valuer logo?

01. Who is eligible to use the RICS Registered Valuer logo? 01. Who is eligible to use the? RICS Registered Valuer is the international mark of valuation expertise, and is open to all RICS qualified members undertaking valuations under RICS Valuation Professional

More information

Graphic Protection Options Overlaminates and clears Product Bulletin

Graphic Protection Options Overlaminates and clears Product Bulletin 3M Europe, Effective June 2013 Graphic Protection Options Overlaminates and clears Product Bulletin Products Standard Overlaminates This Bulletin provides an overview of all 3M graphic protection options.

More information

This document is a preview generated by EVS

This document is a preview generated by EVS CONSOLIDATED VERSION IEC 60958-3 Edition 3.2 2015-06 colour inside Digital audio interface Part 3: Consumer applications IEC 60958-3:2006-05+AMD1:2009-10+AMD2:2015-06 CSV(en) THIS PUBLICATION IS COPYRIGHT

More information

Installation instructions Roxtec RM PE

Installation instructions Roxtec RM PE Installation instructions Roxtec RM PE Environmental side Environmental side Pipe Cable screen/armor Layers Layers Cable sheath Plastic film Conductive tape Integrated environmental sealing system for

More information

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE SPEC NO. TEC-OPTIC-81101A(Rev.4)-2014.07 TECHNICAL PROPOSAL FOR OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE ( Span length : Max. 100m ) APPROVED BY : J.Y. LEE / HEAD OF TEAM ENGINEERING TEAM

More information

2002, Cisco Systems, Inc. All rights reserved.

2002, Cisco Systems, Inc. All rights reserved. 2002, Cisco Systems, Inc. All rights reserved. 1 Panduit Network Infrastructure Essentials Chapter 8 Tools of the Trade Learning Objectives Learn about common tools used in the telecommunications cabling

More information

Class B digital device part 15 of the FCC rules

Class B digital device part 15 of the FCC rules Class B digital device part 15 of the FCC rules The Federal Code Of Regulation (CFR) FCC Part 15 is a common testing standard for most electronic equipment. FCC Part 15 covers the regulations under which

More information

ISO INTERNATIONAL STANDARD. Digital cinema (D-cinema) packaging Part 4: MXF JPEG 2000 application

ISO INTERNATIONAL STANDARD. Digital cinema (D-cinema) packaging Part 4: MXF JPEG 2000 application INTERNATIONAL STANDARD ISO 26429-4 First edition 2008-09-01 Digital cinema (D-cinema) packaging Part 4: MXF JPEG 2000 application Emballage du cinéma numérique (cinéma D) Partie 4: Application MXF JPEG

More information

5S Floor Marking Color Standard

5S Floor Marking Color Standard 5S Floor Marking Color Standard www.bradyid.com/toughstripe Government Regulations & Industry Standards While several OSHA regulations dictate that permanent aisles and passageways must be clearly marked,

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3821:1998 IEC 60406:1997 Australian/New Zealand Standard Cassettes for medical X-ray diagnosis Radiographic cassettes and mammographic cassettes AS/NZS 3821:1998 This Joint Australian/New Zealand

More information

BUREAU OF ENERGY EFFICIENCY

BUREAU OF ENERGY EFFICIENCY Date: 26 th May, 2016 Schedule No.: 11 Color Televisions 1. Scope This schedule specifies the energy labeling requirements for color televisions with native resolution upto 1920 X 1080 pixels, of CRT,

More information

KENYA ELECTRICITY GENERATING COMPANY PLC. KGN-HYD

KENYA ELECTRICITY GENERATING COMPANY PLC. KGN-HYD KENYA ELECTRICITY GENERATING COMPANY PLC. KGN-HYD-050-208. TENDER FOR SUPPLY, INSTALLATION AND COMMISSIONING OF A COMMERCIAL GRADE DISPLAY SCREEN AT KAMBURU CONTROL CENTRE. 7 th January, 209. ADDENDUM

More information

Tender Notification for the procurement of a Scanning Electron Microscope" at IISc (Last Date for submission of tenders: 3 rd October 2018)

Tender Notification for the procurement of a Scanning Electron Microscope at IISc (Last Date for submission of tenders: 3 rd October 2018) Tender Notification for the procurement of a Scanning Electron Microscope" at IISc (Last Date for submission of tenders: 3 rd October 2018) Dear Sir/Madam, We are looking for a high-resolution scanning

More information

Specific Concerns with draft ErP Display Regulation (reference WTO notice EU 433) >> indicates change suggestions.

Specific Concerns with draft ErP Display Regulation (reference WTO notice EU 433) >> indicates change suggestions. To: Internal Market, Industry, Entrepreneurship and SMEs Directorate General Avenue des Nerviens 105 Brussels Belgium, 1040 Email: GROW EU TBT@ec.europa.eu From: Mr. Lauren Crane Manager, Product Environmental

More information

Installation instructions Roxtec RM ES

Installation instructions Roxtec RM ES Installation instructions Roxtec RM ES Environmental side Environmental side Pipe Cable screen/armor Layers Layers Cable sheath Vertical screen Plastic film Conductive tape Integrated environmental sealing

More information

Purchase Now ANSI/ICEA S

Purchase Now ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE Publication S-87-640 Fourth Edition September 2006 Published By Insulated Cable Engineers Association, Inc. (ICEA) P.O. Box 1568 Carrollton,

More information

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA TABLE OF CONTENTS Section Title Page 5901 GENERAL... 2 5902 DESIGN CRITERIA... 2 5902.1 Codes and Standards... 2 5902.2 Signal

More information