Signalling Detection Communication Lighting Installation
|
|
- Rodger Pitts
- 5 years ago
- Views:
Transcription
1 Signalling Detection Communication Lighting Installation
2 "The more we rise and the more we see far. "
3 > Lighting Bulkhead & Pendant light fittings.. p.6 Light fittings for fluorescent lamps. p.14 Floodlights... p.21 Emergency light fittings... p.25 Hand lamps... p.29
4 > Lighting features The A2S company selected products of the biggest European manufacturers. All the products are conceived and made in the United Kingdom and in Italy for a safe use in potentially explosive atmospheres. A2S proposes leading products of the certified market ATEX for a use in dangerous sectors and extreme environments all over the world. The range of lighting includes spots and ceiling lights, as well as fluorescent lighting, antifog, obstruction and portable for a use on network, with cellular or refillable batteries, in low voltage and in compressed air for pneumatic lamps. Everywhere where an explosive gas, the vapor or the dust are present, creating a risk of explosion, there is a guaranteed lamp A2S protection for the Zone 0, Zone 1 and 2 to assure safety. APPLICATIONS : Oil & Gaz offshore installation Naval Refinery and petrochemical industries Food-processing factories Pharmaceutical products Breweries and distilleries Fire-guard wrestling Water treatment Gas distribution... ADVANTAGES : ATEX and IECEx certificated Water- and dustproof /67 Anti-corrosion Mechanical and chemical U.V. stability Thermical stability Very low maintenance Large power range Compact and heavy design 4
5 Série EV p.6 EW p.6 EWA p.7 Series 6050 p.7 Series 6470 p.8 Series 6480 p.8 Ex EL p.9 Ex L p.9 Ex LF p.10 Series 6788 p.10 Series 6388 p.11 RINO-Ex SERIES p.11 RINO-Ex SERIES Oval p.12 RINO-Ex SERIES Oval II p.12 RINO-Ex SERIES Round p.13 Series 6590 p.13 FLFE / FLF p.14 EVF... p.14 EXEL p.15 LXB p.15 AVN p.16 LN p.16 EXEN p / 6414 p.17 ECOLUX 6600 p.18 T-LUX 6035 p / 6412 p.19 EXLUX 6000 / 6400 p.19 C-LUX 6100 / 6500 p.20 Series 6114 / 6514 p.20 SLFE p.21 SLEE p.21 RLEE p.22 FL 878 p.22 PL 870 p p /3 p.24 TIGER p.24 LED 877 p.25 Solas LED Floodlight p.25 NexLED Bulkhead p.26 C-LUX 6108/6118 p.26 Serie 6118 p.27 Lomond p.27 EXLUX 6008/6408 p.28 RINO-Ex SERIES p p.29 HHL20 p.29 HHL70 p.30 HEL15 p.30 HL 800 KP p.31 HL 800 KK p.31 HL 800 PP p.32 SECURLUX p.32 IL 80 p.33 HS6145, HSL145 p p.34 ML 800 p / p.35 Série 6147 p.35 5
6 EV Serie Using zone Max surface T Terminals Weight and dimensions Ex II 2 GD - Ex d IIC T3/T4/T6 T6 : + 85 C / T4 : C / T3 : C GOST R & K (Russian and Kazakh) 230 V 50/60 Hz Halogène, Spiral tube, Linear tube, LED or Mixte Free-copper aluminum body, ceramic cartridge, glass cup it borosilicate Epoxy RAL 7035 painted 2 x M20 2,5 mm2 EW Serie Max. surface T Terminals Weight and dimensions Ex II 2 GD - Ex d IIC T3/T4 T4 : C / T3 : C GOST R & K (Russian and Kazakh), consult us 230 V 50/60 Hz. Sodium or mercury Free-copper aluminum body, ceramic cartridge, glass cup it borosilicate, stainless screws Epoxy RAL 7035 painted 2 x M20 2,5 mm2 6
7 EWA Serie Max. surface T Terminals Weight and dimensions Ex II 2 GD - Ex d IIC T3/T4 T4 : C / T3 : C GOST R and K (Russian and Kazakh), consult us 230 V 50/60 Hz. Sodium, mercury ou iodide metallique lamp Free-copper aluminum body, ceramic cartridge, glass cup it borosilicate Epoxy RAL 7035 painted 2 x M20 2,5 mm Serie Certification T Voltage Installation Terminals Weight and dimensions Ex II 2 G EEx de IIC T3/T4/T5/T6 / Ex II 2 D TO size 1 : C / + 50 C ( C for light with QL lamp) size 3 : C / + 50 C IECEx, India (PESO), Kazakhstan (JSC), Naval(GL) / IP68 (Immersible until 10m of hanging depth 30 min) 220, 230, 240, 250 V AC (± 6 %), 50 Hz, other on demand High pressure sodium lamp Mercury lamp Metal halide lamp Halogen lamp Compact lamp Blended lamp Induction lamp Waterproof aluminum sea case, optional lacquered cover Assembly by rings or stirrups of fixation 2 x M 25 x 1,5; 1 x cable entrie d mm, 1 x obturating cork 4 mm2 7
8 6470 Serie Using zone Certification T Voltage Installation Terminals Weight and dimensions Ex II 3 G EEx nr II T* / Ex II 2 D TO max* / Ex II 3 D TO max* Zones 2, 21 and C to + 40 C IECEx, Russia (CTB), Kazakhstan (JSC), Bielorussia (Gospromnadzor), Ukraine (ISCVE), Naval (GL) 230 V, (± 10%), CA, 50 Hz, other on demand High pressure sodium lamp Mercury lamp Metal halide lamp Halogen lamp Compact lamp Blended lamp Induction lamp Waterproof aluminum sea case, optional lacquered cover Assembly by rings or stirrups of fixation 1,5 x M 25 4 mm2 or 6 mm2 Ceiling mounting without protection basket Ceiling mounting with protection basket Ceiling mounting with reflector 6480 Serie ATEX Certification Using zone Certification T Voltage Installation Terminals Weight and dimensions Zones 1 and 2-25 C to + 40 C / + 50 C IECEx, India (PESO), Kazakhstan (JSC), Naval (GL) 220, 230, 240, 250 V AC (± 6 %), 50 Hz, other on demand High pressure sodium lamp Mercury lamp Metal halide lamp Waterproof aluminum sea case, optional lacquered cover Wall or ceiling mounting ; Mast or duct mounting 2 x M 25 x 1,5; 1 x cable entrie d mm, 1 x obturating cork 4 mm2 8
9 Ex EL Certification T Terminals Option Ex de IIC T3/T4/T5/T6-40 C to + 50 C 220 V 50/60 Hz. High pressure sodium lamp Mercury lamp Low consumption spiral lamp Incandescence lamp Induction lamp Waterproof aluminum sea case, borosilicate glass Epoxy RAL 7035 painted 1 x M25 x 1,5. External diameter 8 to 17 mm 2,5 mm2 Ex L Certification T Terminals Option Ex de IIC T3/T4/T5/T6-40 C to + 50 C 220 V 50/60 Hz. High pressure sodium lamp Mercury lamp Low consumption spiral lamp Incandescence lamp Induction lamp Waterproof aluminum sea case, borosilicate glass Epoxy RAL 7035 painted 1 x M25 x 1,5. External diameter 8 to 17 mm 2,5 mm2 9
10 Ex LF Certification T Voltage Terminals Weight and dimensions Ex mark Ex nr T3/T4/T5/T6 DIP A21 Zones 2, 21 and C to + 50 C 230 V, (± 10%), CA, 50 Hz, other on demand High pressure sodium lamp Metal halide lamp Low consumption spiral lamp Electromagnetic induction lamp Aluminium alloy corrosion-proof and eopxy pooder finishing 3 x M 25 x 1,5 2 x 10 mm Serie Certification T Voltage Installation Terminals Dimensions Ex II 2 G EEx ed IIC T1 / T2 / T3 Zones 1-30 C to + 40 C Kazakhstan (JSC) IP64 Incandescence : 24 and 230V CA / CC, Halogen : 230V CA / CC Incandescence lamp Halogen lamp Wall and ceiling mounting 1 x M 25 x 1,5 cable entrie PE 2 x 4 mm2 192 x 349 x 193 mm 10
11 6788 Serie Certification T Voltage Installation Terminal Dimensions Ex II 3 G Ex na II T1 / T2 Zones 1 and 2-30 C to + 40 C Kazakhstan (JSC) IP64 Incandescence : 24 et 230V CA / CC, Halogènes : 230V CA / CC Incandescence lamp Halogen lamp Wall mounting and ceiling lamp 1 x M 25 x 1,5 cable entrie 2 x 4 mm2 192 x 349 x 193 mm RINO Ex Series Using zone Certification T Reflector Model Ex II 3G EEx na T4 X / Ex II 2D 130 C Zones 2, 21 and C to + 50 C 230V - 50/60 Hz white or aluminium Electromagnetic / electrical / emergency Stainless steel 11
12 Rino Ex Oval Using zone Certification T Installation Weight and dimensions Ex II 3G EEx na T6 Zones 2 and C to + 50 C IP65 230V - 50/60 Hz Wall mounting or embleded Grey RAL ,747 kg x 199 x 100 mm E108A298 E108A299 E108A300 Rino Ex Oval, 60W, wire protective cage, IP65, 1 CG Rino Ex Oval, 100W, wire protective cage, IP65, 1CG Rino Ex Oval, 100W, wire protective cage, IP65, 2CG Rino Ex Oval II Certification T Installation Weight and dimensions Ex II 3G EEx na T4 Zones 2 and C to + 50 C IP65 230V - 50/60 Hz Wall mounting or embleded Grey RAL ,14 kg x 297 x 137 mm E108A301 E108A302 E108A303 Rino Ex Oval, die-cast cage, 200 W, IP65, 1 CG Rino Ex Oval, die-cast cage, 200 W, IP65, 2 CG Rino Ex Oval, die-cast cage, W, IP65, 1 CG 12
13 Rino Ex Round Certification T Installation Weight and dimensions Ex II 3G EEx na T6 Zones 2 and C to + 50 C IP65 230V - 50/60 Hz Wall-mounting or embleded Grey RAL ,936 kg x 184 x 114 mm E108A304 Rino Ex Round, ATEX, 100 W, IP65, 1CG Serie LED 6590 Certification T Connection Weight Option Ex II 3 G Ex na II T5 Zones 2 and C to + 55 C Kazakhstan (JSC), Russia (CTB), Bielorussia (Gospromnadzor) IP64 24 V AC / CC or 48 V AC / CC, 50 / 60 Hz Polycarbonate vasque, polyamide body, EPDM ring Connecting cable ASI, 2 x 1,5 mm2 0,090 kg With fixture plate right or droite or bended E112A310 E112A311 LED 6590, ATEX, 24V AC DC, IP64 LED 6590, ATEX, 48V AC DC, IP64 13
14 FLFE Terminal Weight and dimensions Ex II 2GD Ex de IIC T6 - Ex td A21 IP 66 GOST R and K 230 V 50/60 Hz. Option : rechargeable battery 6V Halogen, Spiral tube, linear tube, LED or mixt - Aluminium alloy body - Glass tube borosilicate shock proof - Stainless steel screws - Joint neoprène résistant aux acides et aux hydrocarbures - Silicon O-ring between entre glass tube and aluminium head Epoxy RAL 7035 finishing 2 x M20 2,5 mm2 EVFD Etanchéité Alimentation Ballast type Options Ex II 2GD Ex de IIC T6 GOST R and K 230 V 50/60 Hz Single electronic channel - Aluminium alloy body - Fluorescent tube 18W, 36W et 58W - Neopren seal Acid and Hydrocarbures resistant - White reflector Epoxy RAL 7035 finish - Galvanized steel protection - Stainless steel protection - Stainless steel reflector - Installation set - Lamp - Silicon seal E202A330 E202A331 E202A332 EVFD, 1060x114x110x561 / 18W EVFD, 1672x114x110x1173 / 36W EVFD, 1972x114x110x1473 / 58W Emergency version, consult us 14
15 EXEL Ballast type Ex II 2GD Ex ed IIC T4/T5 IECEx CES , GOST R and K 110/230 V 50/60 Hz Electronique simple et intérrupteur de sécurité - Antistatic GRP body - Glass protection fire-proof et polycarbonate UV resistant - Interior frame en aluminium extruded - Stainless steel screws 316L 2 x M25 x1,5 Epoxy RAL 7035 finishing Options - Resine polyester grey body - Installation set - Lamp E202A346 EXEL, ATEX,, 785x420x185x155 mm, 2 channels, 1 lamp, 18W E202A347 EXEL, ATEX,, 1370x720x185x155 mm, 2 channels, 1 lamp, 36 W E202A348 EXEL, ATEX,, 785x420x185x155 mm, 2 channels, 2 lamps, 18W E202A349 EXEL, ATEX,, 1370x720x185x155 mm, 2 channels, 2 lamps, 36 W E202A350 EXEL, ATEX,, 785x420x185x155 mm, 1 channel, 1 lamp, 18W E202A351 EXEL, ATEX,, 1370x720x185x155 mm, 1 channel, 1 lamp, 36 W E202A352 EXEL, ATEX,, 785x420x185x155 mm, 1 channel, 2 lamps, 18W E202A353 EXEL, ATEX,, 1370x720x185x155 mm, 1 channel, 2 lamps, 36 W LXB Ballast type Ex II 2GD Ex ed IIC T4/T5 IECEx, GOST R and K 110/230 V 50/60 Hz Electronic single and security switch 2 x M25 x1,5 Options - GRP antistatic body - Glass protection fire-proof et polycarbonate UV resistant - Interior frame en aluminium extruded - Stainless steel 316L screws - Emergency unit : inverter, battery pack and LED signalling - Resin polyester grey body - Installation kit E202A366 E202A367 E202A368 E202A369 LXB, ATEX,, 730x190x195x650 mm, 1 lamp, 18W LXB, ATEX,, 1338x190x195x1258 mm, 1 lamp, 36 W LXB, ATEX,, 730x190x195x650 mm, 2 lamps, 18W LXB, ATEX,, 1338x190x195x1258 mm, 2 lamps, 36 W Emergency version, consult us 15
16 AVN Ex II 3GD Ex na II T4/T5 Zones 2 and 22 GOST R and K IP V 50/60 Hz Double fluorescent tube - GRP antistatic body - Fireproof glass protection and polycarbonate UV resistant - White painted aluminium reflector - Stainless steel aluminium fastening hook - PLG2IXEP socket and UNI2XE polyamide cable gland Epoxy RAL 7035 finishing Options E202A376 AVN, ATEX, 18 W, IP65, 670x100x105x230 mm, 1 lamp E202A377 AVN, ATEX, 36 W, IP65, 1275x100x105x840 mm, 1 lamp E202A378 AVN, ATEX, 58 W, IP65, 1560x100x105x1140 mm, 1 lamp E202A379 AVN, ATEX, 18 W, IP65, 670x100x105x230 mm, 2 lamps E202A380 AVN, ATEX, 36 W, IP65, 1275x100x105x840 mm, 2 lamps E202A381 AVN, ATEX, 58 W, IP65, 1560x100x105x1140 mm, 2 lamps Emergency version, consult us - Fastening hook - Lamp - Surface treatment to protect against the aggression of chemical substances LN Options Ex II 3GD Ex na II T4/T5, Ex II 3D Ex Zones 2 and 22 GOST R and K IP V 50/60 Hz Fluorescent double tube with Ex N protection - Aluminium body - PLG2IXEP socket and UNI2XE polyamide cable gland Epoxy RAL 7035 finishing - Installation kit - Lamp E202A398 E202A399 E202A400 E202A401 LN, ATEX, 18 W, IP65, 730x190x195x650 mm, 1 lamp LN, ATEX, 36 W, IP65, 1338x190x195x1258 mm, 1 lamp LN, ATEX, 18 W, IP65, 730x190x195x650 mm, 2 lamps LN, ATEX, 36 W, IP65, 1338x190x195x1258 mm, 2 lamps Emergency version, consult us 16
17 EXEN Certification ATEX Ballast type Ex II 2GD Ex ed IIC T4/T5 IECEx, GOST R and K 110/230 V 50/60 Hz Single electronic and security switch 2 x M25 x1,5 Options - Glass reinforced polyester black body UV-résistant - Fireproof glass protection and polycarbonate UV resistant - Plastified aluminium internal white frame - Stainless screws - Silicon seals acids and hydrocarbures resistant - Lamp -Polyester resin grey body - Installation kit 6014 / 6414 II 2 G EEx ed IIC T4, II 3 G EEx ed IIC T :, 6414 : Zones 2, 21 and 22 Kazakhstan (JSC), Bielorussia (Gospromnadzor), Homologation Marine (GL) IP 65 (IP 64 with obturating cork) 110/230 V 50/60 Hz Version : 1, 2, 3, 4 tubes 1 cable entry M25 x 1,5 Sheet steel with cover by powder or stainless steel, color: white, similar to RAL
18 Ecolux 6600 Zones d'utilisation Terminal Ex III 3 G Ex na II T4, II Ex td A21 T*, II Ex td A22 T* Zones 2, 21 and 22 IECEx, USA (FM), Canada (CSA), Russia (CTB), Kazakhstan (JSC), Bielorussia (Gospromnadzor), Brazil (UL), Naval (GL) /IP67. IP 64 with respirating cork. IP 54 to 58 W 110/230 V 50/60 Hz 1 or 2 fluorescent tubes 18W, 36 W or 58 W - Polyester reinforces glass case, - Polycarbonate shock resistant bowl Spring border max. 2 x 2,5 mm2 (screw border, consult us) 1 x M 25 x 1,5 cable gland and 2 x M 25 x 1,5 cork T-LUX 6035 Using zone Terminal Options Ex 2 II G Ex d IIC/B T1 IIB et IIC, Ex II 2 D Ex td A21 IECEx IP 66 / IP 68 (10 m) 230 V 50/60 Hz 1 or 2 fluorescent tubes - Aluminium case, lantern useful - Borosicate glass tube (Wall or ceiling mounting) max. 2 x 2,5 mm2 2 x M20 opposed (1 obturating cork) E212A521 E212A522 E212A523 E212A524 E212A525 E212A526 T-LUX 6035, ATEX, 2 x 18 W, ballast electronic 1 channel T-LUX 6035, ATEX, 2 x 18 W, ballast in low loss compensated T-LUX 6035, ATEX, 2 x 36 W, ballast electronic 1 channel T-LUX 6035, ATEX, 2 x 36 W, ballast in low loss compensated T-LUX 6035, ATEX, 2 x 58 W, ballast electronic 1 channel T-LUX 6035, ATEX, 2 x 58 W, ballast in low loss compensated 18
19 6012 / 6412 Options 6012 : Ex II 2 G EEx ed IIC T4 et Ex II 2 D, 6412 : II 3 G EEx na II T4 et Ex II 3 D 6012 :, 6412 : Zones 2 and 22 Belarus (Gospromnadzor), Kazakhstan (JSC) IP65 220/240 V 50/60 Hz 2 or 4 tubes (2 ou 4 x 18 W; 2 ou 4 x 18 W; 2 ou 4 x 36 W; 4 x 36 W; 2 ou 4 x 58 W - Stainless steel body or sticks steel epoxy painting white RAL Central lock Epoxy RAL 9016 finishing or stainless steel in option E212A527 E212A528 E212A529 E212A530 E212A531 E212A , ATEX, 18W, 2 lamps, IP , ATEX, 18W, 4 lamps, IP , ATEX, 36W, 2 lamps, IP , ATEX, 36W, 4 lamps, IP , ATEX, 58W, 2 lamps, IP , ATEX, 58W, 4 lamps, IP65 E212A533 E212A534 E212A535 E212A536 E212A537 E212A , ATEX, 18W, 2 lamps, IP , ATEX, 18W, 4 lamps, IP , ATEX, 36W, 2 lamps, IP , ATEX, 36W, 4 lamps, IP , ATEX, 58W, 2 lamps, IP , ATEX, 58W, 4 lamps, IP65 EXLUX 6000 Terminal Ex II 2 G EEx ed IIC T4 et Ex II 2 D IP65 IECEx, USA (FM), Canada (CSA), Russia (CTB), Kazakhstan (JSC), Bielorussia (Gospromnadzor), Brazil (UL), Naval (GL) (IP64 for installation of a cork respirator) 110/240 V 50/60 Hz 1 or 2 tubes 18 W, 36 W and 58 W - Glass reinforced polyester black body UV-résistant - Fireproof glass protection and polycarbonate UV resistant - Plastified aluminium internal white frame - Stainless screws - Silicon seals acids and hydrocarbures resistant 1x M25 x 1,5 and cable entry 2 x M25 x1,5 obturating cork max. 2 x 6 mm2 (stiff driver); 2 x 4 mm2 (low diam. stiff) 19
20 C-lux 6100 / : Ex II 2 G EEx eds IIC T4, 6500 : II 3 G EEx n A II T4 (T3 for incandescence lamp) Zones 2, 21 and 22 Kazakhstan (JSC) IP 66 (IP 64 with respirating cork) 220/230 V 50/60 Hz Fluorescent : 1 or 2 or 3 x 8W, DULUX L : 1 x 24 W, Incandescence : 1 x 60W or 2 x 40W Terminal 1 x M25 x 1,5 - ABS case - Polycarbonate shock resistant body 2 x 4 mm2 for stiff driver. 2 x 2,5 mm2 for low diameter driver 6114 / 6514 Terminal Options 6114 : II 2 G EEx ed IIC T4, 6514 : II 3 G EEx na II T : zones 1 and 2, 6514 : 2, 21 and 22 IECEx IP V 50/60 Hz Fluorescent : 1 or 2 or 3 x 8W, DULUX L : 1 x 24 W, Incandescence : 1 x 60W or 2 x 40W - Steel case dressed in powder RAL 9016 or stainless steel - White painted reflector - Securit glass 1 x 2,5 mm2 CG 1 x M25 x 1,5 + Socket 1 x M25 x 1,5 Adhesive marking (consult us) 20
21 SLFE Options Ex II 2GD Ex de IIB T2/T3 230 V 50 Hz Sodium vapor, Mercury vapor or metal halide - Body in alloy aluminum with low copper content - Temperature shockproof frontal glass - Galvanized steel hook - Silicone seal Epoxy RAL 7035 finishing Rotative base 360. Lamp SLEE Alimentation Option II 2GD Ex de IIB + H2 T2/T3/T4 IECEx TSA , GOST R and K / IP67 110/240 V 50/60 Hz 1 or 2 tubes 18 W, 36 W and 58 W - Body in alloy aluminum with low copper content - Temperature shockproof frontal glass - Anodized aluminium reflector - Neopren seals - Internal/external stainless steel srews Epoxy RAL 7035 finishing Lamp. Other on demand 21
22 RLEE Options Ex II 2 GD Ex d IIC T3/T4, Ex II 2 GD Ex d IIB T4/T3/T2 GOST R 230 V 50 Hz Sodium vapor, mercury vapor or metal halide - Aluminium alloy body in low copper content - Borosilicate glass - Stainless steel bowl and screws - Anadized aluminium reflector Epoxy RAL 7035 finishing Lamp FL878 Terminal Options Ex II 2 G enr T3 Zones 2, 21 and 22 IP V 50/60 Hz High pressure vapor sodium, metal halide or low consumption - Aluminum case molded under pressure dressed in epoxy powder anti-corrosion - Borosilicate glass - Aluminium reflector 1 x 2,5 mm2 1 x M25 x 1,5 E301A092 E301A093 E301A094 E301A095 E301A096 FL878, ATEX, metal halide, 250 W, FL878, ATEX, metal halide, 400 W, FL878, ATEX, sodium vapor, 250 W, FL878, ATEX, sodium vapor, 400 W, FL878, ATEX, low consumption, 85 W, 22
23 PL870 Terminal Options Ex nr T3 Zones 2, 21 and 22 Nous consulter IP V 50/60 Hz High pressure vapor sodium, metal halide or low consumption - Aluminum case molded under pressure dressed in epoxy powder anti-corrosion - Borosilicate glass - Aluminium reflector 1 x 2,5 mm2 CG 1 x M25 x 1,5 1,5 E301A097 E301A098 E301A099 E301A100 PL870, ATEX, iodures metalliques, 250 W, PL870, ATEX, iodures metalliques, 400 W, PL870, ATEX, vapeur de sodium, 250 W, PL870, ATEX, vapeur de sodium, 400 W, 6121 Option Ex II 2 G EEx de IIC T4/T2 / IIB T4/T2 Kazakhstan (JSC), Russia (CTB), Bielorussia (Gospromnadzor), Naval (GL), consult us IP 66/ V 50 Hz - Halogen lamp (QT) max W - Halogen lamp metal halide (HIT) max. 400 W - High pressure sodium vapor lamp (HST) max. 600 W - Case in cast iron of aluminum - Accessories of stainless steel assembly 2 x M25 x 1,5 (1 cable gland and et 1 cork) Lamp. Other on demand 23
24 6521/3 Options Ex II 3G Ex nr IIC T / 2D Ex td A21 T Zones 2, 21 and 22 China (CQST Ex), Kazakhstan (JSC), Russia (CTB), Bielorussia (Gospromnadzor) 230 V 50 Hz Sodium vapor, halogen or metal halide halogen - Stainless steel body - Reflector in extensive or asymmetric beam 3 x M20 x 1.5 TIGER Terminal Options II 3GD Ex nr II T2/T3 et II 3D Zones 2, 21 and 22 GOST R and K IP V 50/60 Hz High pressure sodium vapor, metal halide or low consumption - Body aluminum molded under pressure - Shockproof treated glass of temperature - Aluminum symmetric or asymmetric oxided reflector and polish Silicon seals - Galvanized steel with index for follow-up of goniometer - PG13 polyamide cable gland 6.6 : in test of waterfalls and the auto-extinction 1 x 2,5 mm2 Epoxy RAL 7035 painting Lampe. Several voltages. 24
25 LED 877 Terminal Options Ex de IIC T6 IP V 50/60 Hz High pressure sodium vapor, metal halide or low consumption - Body aluminum molded under pressure with epoxy powder on surface - Glass borosilicate 1 x 2,5 mm2 Cable gland 2 x M25 x 1,5 1,5 E301A101 E301A102 E301A103 E301A104 LED 877, ATEX, 15 W, LED 877, ATEX, 30 W, LED 877, ATEX, 45 W, LED 877, ATEX, 60 W, Solas LED Emergency Ex de IIB T6 IECEx Certification IECEx BAS Certification EN IP 66/ V 50/60Hz Option 34W LEDs high power - Alloy aluminium LM6 body - Window in toughened glass and stainless steel ties 316L 2 x M20 E411A000 E411A000 E411A000 Solas LED Emergency, ATEX, 34W, -55 to +55 C, regular mode Solas LED Emergency, ATEX, 34W, -20 to +40 C, emergency mode only Solas LED Emergency, ATEX, 34W, -20 to +55 C, regular or emergency mode 25
26 NexLED Terminal Option Ex II 2 GD Ex e ib mb IIC T4 Zones 1 and 21 IEC Ex BAS Baseefa04ATEX0245 /IP V AC/DC 2 x 1W LEDs (green) and 8 x 1W LEDs (green) - Case in alloy aluminum LM6 with pressed glass - Aluminum brushed reflector 4 x 4 mm2 E411A003 E411A003 E411A003 E411A003 Nex LED, ATEX, 2W, /IP67 Nex LED, ATEX, 8W, /IP67 Nex LED emergency, ATEX, 2W, /IP67 Nex LED emergency, ATEX, 8W, /IP67 C-LUX Séries 6108 / : Ex II 2 G EEx eds IIC / II 2 D T75 C 6508 : Ex II 3 G Ex na II T4 / II 2 D T75 C 6108 : zones 1, 2, 21 and : zones 2, 21 and 22 Kazakhstan (JSC) IP 66 (IP 64 with respirating cork) 220/230 V 50/60 Hz 1 x 8W Terminal 1 x M25 x 1,5 - ABS case - Polycarbonate shockproof bowl 2 x 4 mm2 for stiff driver. 2 x 2,5 mm2 for driver of low diameter E412A007 E412A008 C-LUX 6108, ATEX, 8W, C-LUX 6508, ATEX, 8W, 26
27 Série 6118 Terminal Options Ex II 2 G EEx edm IIC T4 Zones 1 and 2 Belarus (Gospromnadzor) IP 65 AC: V, 50 / 60 Hz Fluorescente 1 x 8 W - Steel case dressed in powder RAL 9016 (or optional stainless steel) - White painted reflector - Safety glass 2 x 4 mm2 for stiff driver. 2 x 2,5 mm2 for driver of low diameter 1 cable gland M25 x 1,5 and 2 sockets M25 x 1,5 Adhesive marking (consult us) E412A009 E412A010 E412A , ATEX, Ceiling, 1 x 8W, IP , ATEX, Wall, 1 x 8W, IP , ATEX, Pendant, 1 x 8W, IP65 Lomond Terminal Ex II 2 GD Ex d IIC (8W & 18W) and Ex II 2 GD Ex d IIB (36W) Zones 1 and 21, IP67 and IP V - 254V 50/60Hz (18W, 36W, 58W) et 110V - 130V 50/60Hz (18W, 36W - /120) 1 or 2 tubes 18 W, 36 W and 58 W - Alloy aluminium LM6 body - Borosilicate protection glass - Stainless painted reflector 2 x M20 3 x 4 mm2 for driver with buckle. 4 x 4 mm2 in mode emergency 27
28 Ex LUX 6008 Terminal Option Ex II 2 G Ex edm IIC T4 Zones 1, 21 and 22 IECEx, India (PESO), Kazakhstan (JSC), Russia (CTB), Ukraine (IECVE), Bielorussia (Gospromnadzor), Naval (GL) /IP V, 50 / 60 Hz ( V; 50/60 Hz possible on demand) 2 tubes 18 W and 36 W max. 2 x 6 mm2 (stiff driver), 2 x 4 mm2 (driver of low diameter) E412A023 E412A024 E412A025 E412A025 Ex LUX 6008, ATEX, standard luminous, 2 x 18 W, /67 Ex LUX 6008, ATEX, standard luminous, 2 x 36 W, /67 Ex LUX 6008, ATEX, tube mounting, 2 x 18 W, /67 Ex LUX 6008, ATEX, tube mounting, 2 x 36 W, /67 Rino Ex Serie Option Ex II 3G EEx na T5 X / II 2D 85 C Zones 2, 21 and 22 IP V 50 Hz Fluorescent (1+1) x 18 W or 36 W - Stainless steel body - White or aluminium reflector E408A027 E408A028 E408A029 Rino Ex Emergency, ATEX, (1+1)x36W, white reflector, 1300x200x100 mm, Rino Ex Emergency, ATEX, (1+1)x18W, aluminium reflector, 690x200x100 mm, Rino Ex Emergency, ATEX, (1+1)x36W, aluminium reflector, 1300x200x100 mm, 28
29 6140 Battery Working time Ex II 1 G EEx ia IIC T4 / II 1 D IP65 T130 C Zones 0, 1, 2, 20, 21 and 22 IP65 3 x batteries LR14 > 48 hours (permanent functioning) 1 LED 3 watts high power (very powerful) - Polyamide body, antistatic - Polycarbonate bowl E512A , ATEX, LED 3W, IP65 HHL20 Colors s Working time Weight Option Ex I M2 / II 1G Ex ia I/IIC T4 Zones 0, 1 and 2 DEMKO 07 ATEX IECEx UL IP67 Security colors orange and black White LED 1W Luxeon (luminous flux : 30 lumen) - Body in ultra-shockproof polypropylene - Unbreakable lens it polycarbonate - Neopren seals ultra-resistant in acids and in hydrocarbons 20 hours 116 g (with Alkaline battery) 2 batteries "D" E502A002 HHL20, ATEX, LED 1W, IP67 29
30 HHL70 Color Working time Weight Option Ex I M2 / II 1G Ex ia I/IIC T4 Zones 0, 1 and 2 DEMKO 07 ATEX IECEx UL IP67 Security colors : orange and black White LED 1W Luxeon (luminous flux: 45 lumen) - Polypropylen ultra-shock resistant body - Unbreakable lens it polycarbonate - Neopren seals ultra-resistant in acids and in hydrocarbons 70 hours 448 g (with Alkaline battery) 2 batteries "D" E502A003 HHL70, ATEX, LED 1W, IP67 HEL15 Color s Weight Option Ex I M2 / II 1G Ex ia I/IIC T4 Zones 0, 1 and 2 DEMKO 08 ATEX IECEx UL IP67 Security colors : orange and black White LED CRE XRE (luminous flux : 75 lumen) Aditional LEDs : 2 reds (night) and 1 green (for inspection) - Polypropylen ultra-shock resistant body - Unbreakable lens it polycarbonate 234 g (with Alkaline battery) 3 batteries "AA" E502A004 HEL15, ATEX, LED CRE XRE, IP67 30
31 HL 800 KP Working time Lampe type Color Charging Ex eib op is IIC T3 and Ex I IEC I M2 Zones 1 and 2 Halogen : 3 hours, LED : 2 hours Bulbe halogen 2.4 or LED high intensivity - Polypropylen ultra-shock resistant body - Unbreakable lens it polycarbonate 56 mm x 3 mm - High power battery NiMH 6V NiMH 1350 mah Black Charger for one or two batteries. Ultra-fast charging Weight 512 g (torch 375 g + battery 137 g) E516A005 E516A006 HL 800 KP, ATEX, halogène, HL 800 KP, ATEX, LED, HL 800 KK Working time Lampe type Color Charging Ex eib op is IIC T3 and Ex I IEC I M2 Zones 1 and 2 Halogen : 3 hours, LED : 2 hours Halogen bulb 2.4 or LED high intensivity - Polypropylen ultra-shock resistant body - Unbreakable lens it polycarbonate 56 mm x 3 mm - High power battery NiMH 6V NiMH 1350 mah Black Charger for one or two batteries. Ultra-fast charging Weight 512 g (torch 375 g + battery 137 g) E516A007 E516A008 HL 800 KK, ATEX, halogen, HL 800 KK, ATEX, LED, 31
32 HL 800 PP Working time Color Charging Ex eib op is IIC T3 and Ex I IEC I M2 Zones 1 and 2 Halogen : 3 hours, LED : 2 hours Halogen bulb 2.4 or LED high intensivity - Body in ultra-shockproof polypropylene - Unbreakable lens polycarbonate 56 mm x 3 mm - Battery high power NiMH 6V NiMH 1350 mah Black Charger for one or two batteries. Ultra-fast charging Weight 512 g (torch 375 g + battery137 g) E516A009 E516A010 HL 800 KK, ATEX, halogen, HL 800 KK, ATEX, LED, Securlux Battery Color Weight Option Ex II 2G Ex e ib IIC T3 IP 66 Zones 1 and 2 IP67 6 V 4 Ah. Ni-Cd. Charger 12 VDC and 230 VAC (charging in 24h) Xenon 5,4W (E10) - Thermoplastic housing - Case and battery housing in synthetic material Red and black 3,6 kg E502A001 Securlux, ATEX, Xenon 5,4W, IP67 32
33 IL 800 Battery Working time Lampe type Color Charging Weight Ex II 1G Ex ia IIC T4 Ga / Ex II 2D Ex tb IIIC 100ºC IP67 Db Zones 0, 1 and 2 6V rechargeable NiMH battery IP67 High power : 6 h, Low power : 12 h 3 LEDs high luminous, 200/80 lumen (high/low power). Lifetime : h - Body in ultra-shockproof polypropylene - Toughened glass - High power battery NiMH Black 5,5 h 1,1 kg E516A011 IL 800, ATEX, 3 LED, IP67 HS 6145 Battery Functioning Charging Weight Ex II 2 G EEx e ib IIC T4 Zones 1 and 2 Kazakhstan (JSC) IP54 Battery NiCd, fix securly Main lamp : 4,8 V / 4 W (BA15d); Eco lamp : 4,8 V / 1,5 W (BA9s) Molded plastic, resisting to abrasion, resisting to cold T, antistatic Permanent or twinkling lighting, with main or eco lamp Charger for one or two batteries. Ultra-fast load 1,9 kg E516A012 E516A013 E516A014 E516A015 HS 6145, ATEX, Projector with integrated electronic control, IP54 Charger 230 V, without function of emergency lighting Charger 230 V, with function of emergency lighting 12 V / 24 V, without function of emergency lighting for installation in a vehicle 33
34 6142 Working time Color Charging Battery Ex II 2 G EEx ib IIC T4 Zones 1 and 2 Kazakhstan (JSC) IP54 Switched on constantly during 6 h, Flashing during 2 h Filament (break control - switching automatically on economic lamp Polyamide case, shock resistant, black Black Sector voltage : 230 V AC 50/60 Hz and 12/24 V DC Battery lead with fuse; 4 V; 3,5 Ah E516A016 E516A017 E516A , ATEX, Portable projector without charger, IP , ATEX, Portable projector with charger, IP54 Charger (12/24 V CC and 230 V CA) ML 800 Battery Working time Color Weight and dimensions Option Ex II 2 GD Ex op is IIC T4 / Ex id 21 T1 30 C Zones 21 and 22 6V 1,8Ah rechargeable NiMH battery 7 h 1W or 3W High-Power LED Polypropylen antistatic case ultra shock resistant Yellow and black 370 g x 63 x 54mm E516A019 E516A020 E516A021 ML 800, ATEX, 1W, ML 800, ATEX, 3W, Charger MICA MLC 34
35 6149 Serie Working time Color Weight Ex II 2 G Ex d IIC T4 / Ex II 2 D Ex td A21 IP6X TO max* IECEx, Brazil (UL), Kazakhstan (JSC), Russia (CTB), Bielorussia (Gospromnadzor) / IP67 Halogène : 3 hours, LED : 2 hours 2 or 4 x CCFL 320 mm, cold cathod lamps (130 / 205 Lux at 1 m long) - Handle aluminum dressed of NBR / PVC (EPDM) - Case tube polycarbonate - Aluminium cork black 1,6 kg E516A022 E516A023 E516A024 E516A , 2 lamps, ATEX, 110 to 230 V CA, 50 / 60 Hz 6149, 2 lamps, ATEX, 24 to 48 V CA / CC 6149, 4 lamps, ATEX, 110 to 230 V CA, 50 / 60 Hz 6149, 4 lamps, ATEX, 24 to 48 V CA / CC P Code Replace P with : A = With protection basket S = Without protection basket 6147 Serie Working time Weight Ex II 2 G Ex de IIC T4/T3 & Ex II 2 D Ex td A21 T145 C Kazakhstan (JSC) IP65 Halogen : 3 hours, LED : 2 hours Incandescente, in 25 W, 40 W or 60 W - Body in light metal covered with vulcanized rubber forming the handle - Guard of safety: thread of steel, galvanized and painted, covered with PVC - Shockproof pressing glass of temperature - Ring coutchouc soft absorbing shocks 2,050 kg E516A , ATEX, IP65 35
Pendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationPendant Light Fittings Series 6050
> Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket
More information7 Lighting Technology
7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection
More informationEXLUX ECOLUX C-LUX 6480 Series
EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent
More informationEXLUX ECOLUX 6480 Series
EXLUX ECOLUX 6480 Series L I G H T I N G 6000 6008 6400 6408 6600 6608 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent
More informationEXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder
EXEL - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22 Reinforced polyester resin body G13 bi-pin lamp holder Internal emergency batteries
More informationLighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof
ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof 2 x 58 W Compliance Data: ATEX IECEx: ATEX IECEx CE Ex d IIB Ex d IIC
More informationSAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations
LED Class I, Division 2, Groups A, B, C, & D Class II, Divisions 1 & 2, Groups E, F & G Class III UL 1598A Marine Outside Type UL 1598 Wet Locations UL 844 Hazardous Locations UL 8750 LED Safety Tested
More information3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications
. Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire
More informationEXPlora. Introduction
Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationExplosion Proof Audible Signal db(a) Series YA60
> Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable
More informationHelyum. Vyrtych Product Brochure LOCATION CERTIFICATES REFERENCES. Brezno / Czech Republic CQS,FTZU,EZU,ATEX,CE
2016 Vyrtych Product Brochure LOCATION Brezno / Czech Republic - 1951 CERTIFICATES CQS,FTZU,EZU,ATEX,CE REFERENCES Netherlands VOPAK Project, USA HALLIBURTON Project, Malesia TANJUNG Project, Turkey LUKOIL
More informationChamp-Pak Wall Pack Luminares
Restricted Breathing Cl. I, Div. 2 & Zone 2 ( S826) ( S826TB) Cl. III & Simultaneous Presence Marine & Wet Locations The first low-profile wall pack designed specifically for hazardous areas. The Eaton
More informationOptical Signal Devices. Free-standing Beacons
Free-standing Beacons Overview Free-standing Permanent Beacons Flashing Beacons 200/203 201/204 (LED) 209 209 (LED) 210/213 211/214 (LED) 219 219 (LED) 202 Flashing 205 Flashing 209 Flashing Beacon 212
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationXML LED X M L L E D. Explosionproof Linear LED Lighting
LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924
More informationHazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination
Engineering Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division factory-sealed LED luminaire for general illumination High-performance, high-brightness Hazard Gard EVLL LED Luminaire
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and
More informationLIGHTING SOLUTIONS. The bright side of the ship
LIGHTING SOLUTIONS The bright side of the ship Philosophy Three things you should know about us 1Established by experienced specialists in 1995, Lightpartner has developed into the leading provider of
More informationIllustrated Feature. Options
Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups
More informationJUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full
More informationTFRH Hygienic RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy
More informationLIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances
Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationExplosion Proof Audible Signal db(a) Series YA60
> Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable
More informationM A R I N E B R I G H T S O L U T I O N S
M A R I N E B R I G H T S O L U T I O N S L I G H T I N G F I X T U R E S Sea Bright has become a well-known and sought brand for the design and manufacture of lighting fixtures. The company is oriented
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A
More informationCAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry
CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001
More informationHorn loudspeaker, Ex proof, short/long flare
Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure
More informationWLB SERIES HID Lighting for Hose Down Applications
WLB SERIES W LB HID Lighting for Hose Down Applications Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations NEMA 4X NSF Certified Food Equipment CUL Heavy Hose
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationJUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell
More information- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request
DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationS020 fluorescent tube luminary
S020 fluorescent tube luminary DESCRIPTION: Fluorescent lamps S020 are suitable above all for uniform lighting of bigger areas. Lamps from the range S020 are manufactured from extruded aluminium profile
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationPressure transmitter For applications in hazardous areas Model IS-3
Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine
More informationEx td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread
I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem
More informationUSER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.
d.o.o. tel. 049 900, fax 049 46 450 email: tepex@tepex.hr www.tepex.hr USER MANUAL FOR EPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE. Doc. No: TEPEx.RS.058 Ver : 0 Date: 11.014. SADRŽAJ 1. Manufacturer
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending)
More information9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218
9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,
More informationApplications. Standard Materials
Mercmaster III Low Profile Luminaires : Enclosed and Gasketed Area HID Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing
More informationPRE Series 16 Amp Plugs and Sockets Increased Safety
s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 16 Amp s and Sockets - IK09/10 Applications s and receptacles are used with portable or stationery electrical equipment
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationOperating instructions
108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical
More informationLMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor
LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 26 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Data Sheet Page /5
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationCaveled Tunnel Lighting Series. SL-Caveled/100277AC (UL) - B Type - UL certified (E326344) Features. Typical Applications.
Caveled Tunnel Lighting Series Features ight source: High Power LED NO UV or IR light radiation Special batwing and asymmetrical light patterns. CRI typical 70 Optimized heat management system 100V-240V
More informationI Ex-protected connectors exlink I
Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
Pressure Transmitter for Shipbuilding and Offshore ceramic sensor accuracy: 0.25 % FSO BFSL (0.50 % FSO IEC 60770) nominal pressure ranges from 0... 0.6 bar up to 0... 600 bar The pressure transmitter
More informationLevel Measurement Point level measurement - RF Capacitance switches
Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,
More informationDatasheet EC-750 Ex DOME Camera
Product: EC-750 Ex DOME Camera Description and highlights Explosion proof color TV camera with swivelling head and zoom Chemical, shock and vibration resistant Water- and dustproof IP68 Compact and light
More informationCircuit-Breakers for Motor Protection Series 8523/8
> Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting
More informationModel JDF Field Indicator
Data Sheet DS/JDF-EN Rev. F Model JDF Field Indicator Engineered solutions for all applications Measurement made easy Digital LCD provides reliable and clear indications Flexible configuration facilities
More informationDS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections
Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded
More informationSITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43
Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationGOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET
PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS 3-6VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination
More informationDS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0
More informationAreamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
Areamaster LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2 AEx na IIC, Ex na IIC Type 3R, 4, 4X /67 NEC: Marine Outside Type (Salt Water) Wet Locations Applications
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationl e a d i n g l i g h t
leading light LED Light sources LED Labs has been established in 2006. We are a distributor of technologically advanced LED products and a manufacturer of aluminum profiles for the installation of complete
More informationLevel Measurement Point level measurement RF Capacitance switches
Siemens AG 2018 Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces,
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationDMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.
DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output
More informationDS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection
with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges
More informationGENERAL CATALOGUE EN013 E C
GEERL CTLOGUE F H E013 E C L IDEX Certifications page 3 Foot mounted electric vibrators MVSI MVSI-TS MVSI-CC MVSI-E MVSS CDX MVTX MICRO M3 M3-E MVCC Electric vibrators page 6 Electric vibrators with split
More informationLoudspeakers. < Makes the world sound >
Loudspeakers < Makes the world sound > April 2005 < Makes the world sound > The original DNH design DNH designs and manufactures one of the world's largest range of loudspeakers. New Products Since the
More informationMotor Protection Circuit Breaker Series 8146/5-V27
> For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure
More informationVIA 1.5 LED PENDANT DIRECT W W W. L U M E N W E R X. C O M
AND DIM TO WARM IMPORTANT: a qualified integration consultant is required to ensure proper installation and function of any network ORDER GUIDE Shown with HLO optics DESCRIPTION PROJECT: Via 1.5 is the
More informationSafety dialogue solutions
Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,
More informationMaterial: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More information3 Large Housing. Assembly Guide. To order a UNIPAK fixture, see page 29. Complete luminaire consists of : To order separate components, order
Assembly Guide Complete luminaire consists of : a Mounting Style Ballast Tank Globe or Refractor Optional Guard and/or Refractor To order a UNIPAK fixture, see page 29. To order separate components, order
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationHeavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas
Heavy industrial LED lighting Champ Pro PFM LED luminaires Champ PFM LED floodlights for heavy industrial areas Champ Pro PFM LED floodlights Safe. Reliable. Efficient. Featuring the industry's broadest
More informationDMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure
More informationWFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations
WFH SERIES W FH Fluorescent High-Bay Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL Listed for Wet & Hazardous Locations CUL Listed
More information12W LED Underground OPTIONS ON REQUEST. 160mm LED UNDERGROUND LIGHT. Item Code: Model No.: RS-UG12W-PM. 110mm 145mm
-High efficiency light source, Cree 1W high power led. -High quality 304SS+ Alumimum lamp fixture, Beautiful appearance and reasonable w aterproof structure. -Tempered glass as cover, heat-resisting and
More informationFigure 1. High Efficiency T8 LED Tube. Figure 3. Full View of Light High Efficiency T8 LED Tube
Figure 1. Figure 2. Lighting the with Enclosure Figure 3. Full View of Light Copyrights 2000-2013, Analog Technologies, Inc. All Rights Reserved. Updated on 1/31/2013. 1 FEATURES Cut electricity bill by
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationChamp VMV LED luminaires for hazardous areas
Hazardous Area LED Lighting Champ VMV LED Luminaires Champ VMV LED luminaires for hazardous areas 3,000 to 25,000 lumen LED high bay luminaires Champ VMV LED Safe. Reliable. Efficient. Featuring the industry's
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationDMP 331i / DMP 333i LMP 331 i
DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma
More informationNEW! Wide Area Lighting - Rough Service Fluorescent. MULTIVOLTAGE Automatically Operates at 120 to 277 VAC 50 or 60 Hz *1142 only
Wide Area Lighting - Rough Service Fluorescent 1100 and 1200 Series Wide Area Lighting These portable overhead lights have been engineered to meet the need for safe, temporary, economical lighting for
More informationMaterial: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More informationMODEL HS35 DRAWWORKS OPTICAL ENCODER
MODEL HS35 DRAWWORKS OPTICAL ENCODER Product Description This specially configured DrawWorks Model HS35 encoder combines rugged, heavy-duty features into a unique through-shaft style for use as a winchturns
More informationFlow Measurement SITRANS F M
Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate
More informationFOUNTAIN LIGHTING. Adding light to your life. atecpool.com
FOUNTAIN LIGHTING Adding light to your life atecpool.com 133 Fountain Ring LED Light Atecpool Fountain Ring LED Lights - AYP Series Made of S.S. 316 Ring Series Circular LED Lights with a central hole
More informationMax. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm
21.610/1 RAK: Universal thermostat How energy efficiency is improved Demand-led controlling, monitoring and limiting, without auxiliary energy. Areas of application For controlling and monitoring the temperature
More information>Inductive. REFERENCE guide. Proximity
>Inductive REFEREE guide Proximity DATALOGIC: SOLUTIONS FOR INDUSTRIAL AUTOMATION Datalogic Industrial Automation is an industry-leader in products and solutions for material handling, traceability, inspection
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationINSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN
INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN 1.1 TECHNICAL DATA PRODUCT DESCRIPTION Screens made with the following projection fabrics: SOFT WHITE, MATT WHITE SOFT, SOFT WHITE TRANSOUND,
More informationKRONA-IV Recessed LED Downlight
Recessed LED Downlight Recessed LED Downlight KRONA-IV is a fixed recessed down light using 4 high power LEDs. Typical applications include general and display lighting for retail locations, office and
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.
Siemens G 2009 Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits
More informationPMG. Vibration Energy Harvesters
FEATURES Designed to power high performance Wireless Sensor Nodes. High power output up to 27.5mW High reliability design, including hermetically-sealed stainless steel case. Intrinsically Safe for use
More information