Liquid Level Sensor AKS 4100/4100U
|
|
- Cassandra Elliott
- 5 years ago
- Views:
Transcription
1 MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sens /4100U /4100U - Cable Version /4100U - Coaxial Version The /4100U liquid level sens is designed specifically measure liquid levels in a wide range of refrigeration applications. The /4100U liquid level sens is based on a proven techhology called Time Domain Reflecmetry (TDR) Guided Micro Wave. /4100U liquid level sens can be used measure the liquid level of many different refrigerants in vessels, accumulars, receivers, standpipes, etc. The electrical output is a 2-wired, loop powered 4-20 ma output signal, which is proptional the refrigerant liquid level. /4100U in a cable version is suitable f most commonly used refrigerants, including R717(ammonia), HCFC, HFC and non crosive gases/ liquids except CO 2, and differing lengths from 800 mm(31.5 in.) and up (197 in.). The coaxial version of /4100U is designed f use with CO 2. It can also be used f all other appoved commonly used refrigerants. The /4100U coaxial version should always be used f marine applications f all refrigerant types. The /4100U cable version should T be used f CO 2 marine applications. Dust, foam, vapour, agitated surfaces, boiling surfaces, changes in density in the dielectric constant, εr, f the liquid have no influence on the /4100U perfmance. Oil accumulated in the botm of a standpipe will not disturb the liquid level signal and it is not necessary remove /4100U f cleaning after oil has been drained out of the standpipe. Features Approved and qualified by Danfoss f refrigeration applications One product covering several probe lengths (cable version) A single product f all commonly used refrigerants (cable version) Cable version requires less p-end clearance f installation and service Proven operation with all refrigerants in combination with oil. No need clean cable version when fully covered by oil. The cable version is very compact and easy handle, ship, install and use with different lengths and refrigerants Changes of the liquid dielectric constant (εr) do not affect operation. (197 in.) probe length with cable version 2-wire loop powered; no separate transfmer needed. Please Note: If used gether with Danfoss EKC 347 Level Controller, a V d.c supply is required. Multi language HMI. Level and setting readout in mm,cm,m( ft, in.) F further details regarding mechanical and electrical installation please refer the product instructions PI.SC0.D (CABLE version) and PI.SC0.E (COAXIAL version). Danfoss A/S (AC-MCI/MWA), DKRCI.PD.SC0.C3.02 / 520H5687 1
2 Liquid Level Sens, /4100U Contents Page Features... 1 Product concept: CABLE version:... 3 COAXIAL version:... 4 Optional HMI... 4 Measuring principle... 5 Main technical data... 5 Measuring range of /4100U - CABLE version... 6 Measuring range of /4100U - COAXIAL version... 7 Ordering /4100U... 8 Dimensions and weights...9 Technical data Quick setup: CABLE version COAXIAL version Fcing ma output Entering refrigerant dielectric gas constant Saturated vapour dielectric constant How change the language setting (Default: English) Reset facry setting DKRCI.PD.SC0.C3.02 / 520H5687 Danfoss A/S (AC-MCI/MWA),
3 Liquid Level Sens, /4100U Product concept /4100U is available in two different versions: Cable version Coaxial version Both Cable and Coaxial versions are available with two different mechanical process connections: : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT CABLE version: COAXIAL version: Danfoss M84H0021_1 Danfoss M84H0001_1 Cable version Cable version The cable version consists of: Signal converter, which can be supplied with without HMI Mechanical process connection with 5 m (197 in.) ø2 mm (0.08 in.) stainless cable Counterweight Accessy bag comprising: 3 mm set screws Red cover protect mechanical process connection pri mounting signal converter. Setting label. /4100U cable version must ALWAYS be installed in a standpipe. With the cable version it is possible adapt the /4100U any possible length in the range of 800 mm (31.5 in.) (196.9 in.) Danfoss A/S (AC-MCI/MWA), DKRCI.PD.SC0.C3.02 / 520H5687 3
4 Liquid Level Sens, /4100U Coaxial version Coaxial version The Coaxial version consists of: Signal Converter (with without HMI) Mechanical process connection with 5 m (197 in.) Ø2 mm (0.08 in.) stainless wire Tube(s) depending on required length Accessy bag comprising: End Connecr (incl. 3 mm (0.12 in.) set screws.) 3 mm (0.12 in.) set crews (1 set screw pr. tube) Red cover protect mechanical process connection, befe Signal Converter is mounted. Setting label. The coaxial version is available in the following probe lengths:, 500 mm, 800 mm, 1000 mm, 1200 mm, 1500 mm, 1700 mm, 2200 mm U, 19.2 in. U, 30 in. U, 45 in. U, 55 in. U, 65 in. U, 85 in. /4100U, Coaxial can be installed in a standpipe (a) directly in a vessel (b). a b Optional HMI The optional HMI Service/Display unit is used f commissioning and quick on-site setup and is easily mounted on the /4100U. The service unit suppts mulitple languages in both SI and US units. Suppted standard languages: English (default), German, French, Spanish * 4-20 ma output displayed as bar graph and in percentage [%] Measurement name (in this example, ) Device tag name ➃ Measurement reading and unit ➄ Device status (markers) 1 = Hardware problem (any hardware problem making the device unable provide a crect measurement (communication, memy problem ) 2 = No Reference Pulse 3 = Low Voltage Measurement Old 4 = Level Lost ➅ Keypad butns ➆ Flashing star indicating unit in operation. Enter menu system Enter QUICK SETUP Unit change at distance/level readout: m, cm, mm, in, ft * is a display option. If the display is set the displayed value will be the distance from the Reference point the p surface of the liquid refrigerant (see page 7 and 8). ** LEVEL is display option. If the display is set LEVEL then the value displayed will be: PROBE LENGTH (entered in QUICK SETUP) (see page 7 and 8). Change between: Distance* Level** Output (%)*** Output (ma)**** *** OUTPUT (%) is display option. Will represent the level of refrigerant,in percent, scaled (entered in QUICK SETUP) accding : SCALE 4 ma (0%), SCALE 20 ma (100%) (see page 7 and 8) **** OUTPUT I (ma) is display option. Will represent the level of refrigerant,in 4-20 milliampere, scaled (entered in QUICK SETUP) accding : SCALE 4 ma (4 ma), SCALE 20 ma (20 ma) (see page 7 and 8). 4 DKRCI.PD.SC0.C3.02 / 520H5687 Danfoss A/S (AC-MCI/MWA),
5 Liquid Level Sens, /4100U Measuring principle (Cable and Coaxial) 1. The electromagnetic (EM) pulse is transmitted by the signal converter 2. The pulse goes down the probe at the speed of light in air, V1 3. The pulse is reflected 4. The pulse goes up the probe at speed, V1 5. The converter receives the pulse and recds the signal 6. The EM pulse moves at speed, V1 7. Transmitted EM pulse 8. Half of this time is equivalent the distance from the reference point of the device (the flange facing) the surface of the product 9. Received EM pulse Main technical data (see a complete list of all technical data on page 11) The /4100U electronic converter emits low-intensity, high frequency electromagnetic pulses with a width of approximately 1 nanosecond, which travel at the speed of light along the probe (wire coaxial cable) down the liquid surface. The pulses are reflected by the liquid surface, guided back along the probe, and received and analysed by the /4100U electronic converter and then converted in a liquid level reading. This method is called time domain reflecmetry (TDR) guided microwave. The dielectric constant, εr, of the liquid is a key parameter and has a direct impact on the degree of reflection of the high frequency electromagnetic pulses. Liquids with high εr values, such as ammonia, produce strong reflections, while liquids with low εr values, such as CO 2, produce weak reflections. Supply Voltage V d.c. Min/Max. Value f an output of 22 ma at the terminal. Ambient temperature supply voltage limitations: -40 C/+80 C( 40 F / +176 F) : V d.c. -20 C/+80 C( 4 F / +176 F) : V d.c. Load RL [Ω] ((Uext -14 V)/20 ma). Default (Err output set 3.6 ma) RL [Ω] ((Uext -14 V)/22 ma). (Err output set 22 ma) Cable gland PG 13, M ; (cable diameter: 6-8 mm ( in.) U ½ in. NPT temperature 60 C/100 C ( 76 F/212 F) Ambient temperature 40 C / +80 C ( 40 F / +176 F) F HMI : 20 C / +60 C ( 4 F / +140 F) Process pressure 1 barg / 100 barg ( 14.5 psig / 1450 psig) Terminals (spring loaded) mm² (~20-15 AWG) Enclosure: IP 66/67 (~NEMA type 4X) As long as the εr value of the liquid refrigerant is higher than 1.2, /4100U can detect the liquid level and level measurement accuracy is not affected. If the temperature condition in the standpipe/ vessel is known, a constant (dielectric constant of the refrigerant gas) can be entered (parameter GAS EPS.R), in der obtain improved Top and Botm Dead Zone values. Refer pages 7 8 f Measuring range of AKS 4100/4100U - CABLE version and COAXIAL version. F details of gas constant values f different temperatures and refrigerants plus the procedure f entering these via the HMI, refer pages Mechanical connection Cable version/coaxial version: : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT s The listed refrigerants are qualified and approved by Danfoss R717 / NH 3 40 C / +50 C ( 40 F / +122 F) R744 / CO 2 50 C / +15 C ( 58 F / +59 F) HCFC: R22 50 C / +48 C ( 58 F / +118 F) HFC: R404A 50 C/ +15 C ( 58 F / +59 F) R410A 50 C /+15 C ( 58 F / +59 F) R134A 40 C /+50 C ( 40 F /+122 F) The listed refrigerants may be used in the complete temperature range of /4100U, however, the accuracy may be affected if the above listed temperature range is exceeded. Other refrigerants within the groups of HCFC and HFC can be detected and measured if the following conditions are fulfilled: Reference conditions Dielectric constant Cable version be used in R717 / NH 3, HCFC and HFC εr, liquid > 5.6 The coaxial version is mandary f R744 / CO 2 εr, liquid > 1.3 and marine applications. The coaxial version can also be used in R717 / NH 3, HCFC and HFC. Danfoss A/S (AC-MCI/MWA), DKRCI.PD.SC0.C3.02 / 520H5687 5
6 Liquid Level Sens, /4100U Measuring range of /4100U - CABLE version Botm deadzone values based on the facry setting of dielectric constant length range Botm dead zone Ammonia, HFC, HCFC [mm] [in.] [mm] [in.] Improved Botm dead zone values after the adjustment of dielectric constant length range Botm dead zone Ammonia, HFC, HCFC [mm] [in.] [mm] [in.] Top dead zones 120 mm (4.7 in.) Measuring range Standpipe diameter: 2-4 in. Reference point length* 20 ma (100 %)* Surface level Distance 4 ma (0 %)* Inner length of the standpipe * Values be entered in HMI Quick Setup menu and recded on the setting label. Stick the setting label on the Signal Converter either inside outside. Botm dead zone (see tables) Counterweight: 33 mm (1.3 in.) Danfoss M84H0017_1 Steel wire insertion length: 12 mm (0.5 in.) Min: 20 mm (0.8 in.) 6 DKRCI.PD.SC0.C3.02 / 520H5687 Danfoss A/S (AC-MCI/MWA),
7 Liquid Level Sens, /4100U Measuring range of /4100U - COAXIAL version Please note: It is mandary input dielectric constant f CO 2 applications. Dielectric Constant εr always set during Quick Setup Botm Botm Dead Dead Zone Zone [mm] [in.] [mm] [in.] CO U Dielectric Constant εr always set during Quick Setup Botm Botm Dead Dead Zone Zone [in.] [in.] [mm] CO Top dead zone 120 mm (4.7 in.) Reference point 20 ma (100 %)* Facry setting Ammonia Botm Dead Zone Botm Dead Zone [mm] [in.] [mm] [in.] Improved Botm dead zone values after the adjustment of dielectric constant Ammonia Facry setting HCFC,HFC Botm Dead Zone Botm Dead Zone [mm] [in.] [mm] [in.] Botm Dead Zone Botm Dead Zone [mm] [in.] [mm] [in.] Improved Botm dead zone values after the adjustment of dielectric constant HCFC,HFC Botm Dead Zone Botm Dead Zone [mm] [in.] [mm] [in.] Facry setting Ammonia Botm Botm Dead Dead Zone Zone [in.] [in.] [mm] Improved Botm dead zone values after the adjustment of dielectric constant Botm Botm Dead Dead Zone Zone [in.] [in.] [mm] Ammonia Facry setting HCFC,HFC Botm Botm Dead Dead Zone Zone [in.] [in.] [mm] Improved Botm dead zone values after the adjustment of dielectric constant Botm Botm Dead Dead Zone Zone [in.] [in.] [mm] HCFC,HFC Measuring range Botm dead zone (see tables) Danfoss M84H0026_1 Standpipe diameter: 2-4 in. length* Surface level Min: 30 mm (1.2 in.) Ø2 mm (0.08 in.) stainless wire Distance 4 ma (0 %)* * Values be entered in HMI Quick Setup menu and recded on the setting label. Stick the setting label on the Signal Converter either inside outside. Inner length of the stand pipe Danfoss A/S (AC-MCI/MWA), DKRCI.PD.SC0.C3.02 / 520H5687 7
8 Liquid Level Sens, /4100U Ordering /4100U Cable version - /4100U Description * When dering without HMI please observe: Code number With HMI Code number Without HMI* with 5 m (197 in.) Ø2 mm (Ø0.08 in.) stainless cable and counterweight 084H H4500 U with 5 m (197 in.) Ø2 mm (Ø0.08 in.) stainless cable and counterweight 084H H4520 Each / must always be programmed via the HMI display unit. The HMI display unit can be dered separately and there are two possibilities: 084H4540 /4100U HMI display unit with rear cover and mounting bracket. The mounting bracket is very useful when the AKS 4100/4100U have be programmed. The same /4100U HMI display unit can be used programme me AKS 4100/4100U and both Cable and Coaxial versions. Coaxial version - /4100U (available in predefined lengths, with without HMI) Description length mm 084H4548 /4100U HMI display unit (usually spare part). in. Code number With HMI Code number Without HMI* - Coaxial H H Coaxial H H Coaxial H H Coaxial H H Coaxial H H Coaxial H H Coaxial H H4509 U - Coaxial H H4524 U - Coaxial H H4525 U - Coaxial H H4526 U - Coaxial H H4527 U - Coaxial H H4528 U - Coaxial H H4529 Accessies Description Code number /4100U HMI Service/Display unit with rear cover and mounting bracket 084H4540 /4100U HMI Display 084H4548 Description Code number /4100U Signal Converter without HMI, excluding cable gland 084H4541 Service kits Description Cable and counterweight f /4100U - CABLE version Content Code number Cable - 5 m (197 in.) Ø2 mm (Ø0.08 in.) 084H4542 Crimp Counterweight End connecr incl screws f /4100U - COAXIAL version End connecr (incl. 3 mm (0.12 in) set screws) Process connection, counterweight and 5 m (197 in.) Ø2 mm (Ø0.08 in.) cable f - CABLE and COAXIAL version 1in. process connection Process connection, counterweight and 5 m (197 in.) Ø2 mm (Ø0.08 in.) cable f U - CABLE and COAXIAL version 3/4in. NPT process connection Counterweight Counterweight 084H H H4546 Other spare parts Description 8 Code number /4100U Coaxial tube. Tube length : 680 mm (26.8 in.) 084H4543 /4100U blank p cover f signal converter 084H4544 /4100U Aluminium gaskets (10 pcs.) f 1in. process connection 084H in. welding connection 027F1010 DKRCI.PD.SC0.C3.02 / 520H5687 Danfoss A/S (AC-MCI/MWA),
9 Liquid Level Sens, /4100U Dimensions and weights CABLE version Ø104 mm (Ø4.1 in.) Ø2 mm Ø0.08 in. 33 mm 1.3 in. Ø22 mm Ø0.9 in. Ø92 mm Ø3.6 in mm (5.6 in.) 34.2 mm 1.4 in. length Weight: approx. 2.0 kg (4.4 lbs) COAXIAL version Ø104 mm (Ø4,1 in.) Ø14 mm Ø0,6 in. Ø21 mm Ø0,8 in. 141,3 mm (5,6 in.) 34,2 mm 1,4 in. Lunghezza sonda Weight: approx. 3.5 kg (7.7 lbs) Danfoss A/S (AC-MCI/MWA), DKRCI.PD.SC0.C3.02 / 520H5687 9
10 Liquid Level Sens, /4100U Technical data Measuring system Measuring principle 2-wire loop-powered level transmitter; Time Domain Reflecmetry (TDR ) Application range Level measurement of liquid refrigerants. Approved refrigerants: Primary measured value Secondary measured value Halogen Free / Environmently friendly: R717 / NH 3, R744 / CO 2 HCFC: R22 HFC: R404A, R410A, R134A Time between the emitted and received signal Distance level Design Options Max. measuring range types Cable Mechanical process connection with 5 m (197 in.) Ø2 mm (0.08 in.) stainless cable: Mechanical thread on the mechanical process connection : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT Coaxial Mechanical process connection with 5 m (197 in.) Ø2 mm (0.08 in.) stainless cable: Mechanical thread on the mechanical process connection : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT Stainless steel tubes suppting the available probe length LCD display Coaxial : 500, 800, 1000, 1200, 1500, 1700 and 2200 mm U: 19.2, 30, 45, 55, 65, 85 in. Single cable Ø2 mm / 0.08 in.: 800- ( in.) Dead zone This depends on the type of probe. (see pages 7 and 8) Display and User interface Display Interface languages Operating conditions : Ambient temperature Srage temperature Process connection temperature ure: Operating pressure Other conditions: Liquid dielectric constant (εr) Vibration resistance Protection categy Integrated LCD display pixels in 8-step greyscale with 4-butn keypad English (default), German, French, Spanish 40 C / +80 C ( 40 F / +175 F) F HMI : 20 C / +60 C ( 4 F / +140 F) C / F Standard 60 C/100 C ( 76 F/212 F) Standard: 1 barg / 100 barg ( 14.5 psig / 1450 psig) Cable version be used in R717 / NH 3, HCFC and HFC εr, liquid > 5.6 Coaxial version is mandary in R744 / CO 2 εr, liquid > 1.3 EN (1...9 Hz: 3 mm / Hz:1g; 10g shock half-wave sinusoidal: 11 ms) IP 66/67 equivalent NEMA type 4X (housing) and type 6P (probe) Installation conditions Dimensions and weights See page DKRCI.PD.SC0.C3.02 / 520H5687 Danfoss A/S (AC-MCI/MWA),
11 Liquid Level Sens, /4100U Technical data (continued) Material Housing Aluminium Coaxial (segmented) Standard: Stainless steel ( / 316L) Single cable Standard: Stainless steel ( / 316) Process fitting Standard: Stainless steel ( / 316L) Gaskets EPDM ( C / F) Cable gland Plastic (black) Process connections Thread: Single cable Ø2 mm / 0.08 Coaxial Electrical connections Power supply Current output load Cable gland Cable entry capacity (terminal) : G1 inch pipe thread. Aluminium gasket included U: ¾ in. NPT : G1 inch pipe thread. Aluminium gasket included U: ¾ in. NPT Terminals output: V d.c. Min./Max. Value f an output of 22 ma at the terminal. Ambient temperature limitations: -40 C/+80 C( 40 F / +176 F) : V d.c. -20 C/+80 C( 4 F / +176 F) : V d.c. RL [Ω] ((Uext -14 V)/20 ma). Default (Err output set 3.6 ma) RL [Ω] ((Uext -14 V)/22 ma). (Err output set 22 ma) : PG 13, M ; (cable diameter: 6-8 mm ( in.) U: ½ in. NPT mm 2 (~20-15 AWG) Input and output Current output: Output signal 4 20 ma ma acc. NAMUR NE 43 Resolution drift Err signal ±3 μa Typically 75 ppm/k High: 22 ma; Low: 3.6 ma acc. NAMUR NE 43; Hold (frozen value - not available with NAMURNE 43 compliant output. Approvals and certification CE Other standards and approvals: EMC LVD NAMUR This device fufills the statury requirements of the EMC directives. The manufacturer certifies successful testing of the product by applying the CE mark. EMC Directives 2004 / 108 / EC and 93 / 68 / EEC in conjunction with EN (2006) and EN (2006). The device confms these standards if : - the device has a coaxial probe - the device has a single probe that is installed in a metallic tank. Low-Voltage Directives 2006 / 95 / EC and 93 / 68 / EEC in conjunction with EN (2001) NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and Labary Control Equipment NAMUR NE 43 Standardization of the Signal Level f the Failure Infmation of Digital Transmitters Minimum power supply voltage Use this graph find the minimum power supply voltage f a given current output load: Current output load R L [Ω] Power supply U [VDC] Minimum power supply voltage f an output of 22mA at the terminal Danfoss A/S (AC-MCI/MWA), DKRCI.PD.SC0.C3.02 / 520H
12 Liquid Level Sens, /4100U Note: The signal converter can be programmed with without mechanical process connecr assembled. Quick Setup (all values below are only examples) Connect the device the power supply (see the section "Electrical installation/ connection". 3 times. SCALE 20 ma mm STORE select either STORE STORE. QUICK SETUP? change of SCALE 4 ma. change the curs position. decrease the value Default screen appears: PROBE TYPE SINGLE CABLE select either SINGLE COAXIAL. PROBE LENGTH 0 change of SCALE 20 ma. change the curs position. decrease the value Quick Setup completed You have the possibility of checking your settings by pressing twice. QUICK SETUP COMPLETED IN 8 change the PROBE LENGTH. change the position of the curs. decrease the value Wait f QUICK SETUP complete 8-second timeout AKS 4100 QUICK QUICKSTART SETUP? SINGLE CABLE (0%) 4 ma (100%) 20 ma default screen mm 120 mm return SCALE 4 ma mm 12 DKRCI.PD.SC0.C3.02 / 520H5687 Danfoss A/S (AC-MCI/MWA),
13 Liquid Level Sens, /4100U COAXIAL version Quick Setup (all values below are only examples) When CO2 is used: Connect the device the power supply (see the product instruction f detail on electrical installation/connection). 3 times. change the PROBE LENGTH. change the position of the curs. decrease the value QUICK SETUP? PROBE TYPE SINGLE CABLE PROBE LENGTH 0 QUICK SETUP COMPLETED IN 8 Wait f QUICK SETUP complete. Count down from 8 sec. AKS 4100 QUICK QUICKSTART SETUP? STORE SCALE 4 ma mm select between SINGLE COAXIAL. Choose COAXIAL and press LIQUID CO2? () confirm change of SCALE 4 ma. change the curs position. decrease the value select between STORE STORE. Default screen appears: SCALE 20 ma mm GAS EPS R? change GAS EPS.R. (Select the crect value from the tables on page 16) change cursposition. decrease the value change of SCALE 20 ma. change the curs position. decrease the value Quick Setup completed You have the possibility of checking your settings by pressing twice. COAXIAL 2200 mm (0 %) 4 ma 1900 mm (100 %) 20 ma 70 mm return default screen. F all other refrigerants: Connect the device the power supply 3 times. QUICK SETUP? change the PROBE LENGTH. change the position of the curs. decrease the value QUICK SETUP COMPLETED IN 8 Wait f QUICK SETUP complete. Count down from 8 sec. AKS 4100 QUICK START SETUP? SCALE 4 ma mm PROBE TYPE SINGLE CABLE select between SINGLE COAXIAL. Choose COAXIAL and press change of SCALE 4 ma. change the curs position. decrease the value SCALE 20 ma LIQUID CO2? mm () confirm PROBE LENGTH 0 Danfoss A/S (AC-MCI/MWA), change of SCALE 20 ma. change the curs position. decrease the value DKRCI.PD.SC0.C3.02 / 520H5687 STORE select between STORE STORE. Default screen appears: Quick Setup completed 13
14 Liquid Level Sens, /4100U CABLE and COAXIAL version Fcing ma output (all values below are only examples) Default screen 4 times return default screen TESTS Default screen appears: AKS 4100 START? QUICK SETUP SET OUTPUT Fce ma completed and disabled SUPERVISOR SET OUTPUT 3.5 ma decrease the value SET OUTPUT 8 ma Enter passwd: INFORMATION Optional Procedure If the temperature condition in the stand pipe is known, a constant (dielectric constant of the refrigerant gas) can be entered (parameter GAS EPS.R), in der obtain lower Top and Botm Dead Zone values (see pages 7 and 8). Entering refrigerant dielectric gas constant (all values below are only examples) Default screen AKS 4100 QUICK START SETUP? GAS EPS. R APLICATION 4 times TRACING VEL. 3 times. STORE SUPERVISOR 2 times GAS EPS. R select between STORE STORE. Select STORE by pressing Default screen appears: Enter passwd: INFORMATION 14 change GAS EPS.R. (Select the crect value from the tables on page 16) change cursposition. decrease the value Entering the dielectric constant of refrigerant gas completed GAS EPS. R DKRCI.PD.SC0.C3.02 / 520H5687 Danfoss A/S (AC-MCI/MWA),
15 Liquid Level Sens, /4100U Saturated vapour dielectric constant (default value: 1.066) R717 (NH 3 ) range: 40 C +50 C ( 40 F +122 F) [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R R744 (CO 2 ) range: 50 C +15 C ( 58 F +59 F) [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R R22 range: 50 C +48 C ( 58 F +118 F) [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R R134a range: 40 C +50 C ( 40 F +122 F) [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R R410A range: 50 C +15 C ( 58 F +59 F) [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R R404A range: 40 C +15 C ( 40 F +59 F) [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R Danfoss A/S (AC-MCI/MWA), DKRCI.PD.SC0.C3.02 / 520H
16 Liquid Level Sens, /4100U How change the language setting (Default: English) Default screen Enter passwd: INFORMATION AKS 4100 START? QUICK SETUP LANGUAGE 6 times DISPLAY see the language possibilities STORE LANGUAGE SUPERVISOR LANGUAGE ENGLISH times select between STORE STORE. Select STORE by pressing Default screen appears: Language setup completed Reset facry setting Default screen Enter passwd: once and SERVICE twice twice CONFIG/RESET RESET FACTORY SENSOR Select by pressing with and confirm 3 times return default screen. Default screen appears: RESET FACTORY Facry reset completed 16 DKRCI.PD.SC0.C3.02 / 520H5687 Danfoss A/S (AC-MCI/MWA),
Liquid Level Sensor Type AKS 4100/4100U
Data sheet Liquid Level Sensor Type /4100U /4100U - Cable Version /4100U - Coaxial Version The /4100U liquid level sensor is designed specifically measure liquid levels in a wide range of refrigeration
More informationLiquid Level Sensor AKS 4100U
MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sensor U U - Cable Version U - Coaxial Version The U liquid level sensor is designed specifically to measure liquid levels in a wide range
More informationLiquid Level Sensor Type AKS 4100U
Data sheet Liquid Level Sensor Type U U - Cable Version U - Coaxial Version The U liquid level sensor is designed specifically to measure liquid levels in a wide range of refrigeration applications. The
More informationLiquid Level Sensor AKS 4100U
MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sensor U www.danfoss.us Liquid Level Sensor, U Contents Page Introduction...3 Features...3 Product concept...3 Cable Version...................................................................................3
More informationType AKS 4100/4100U Coaxial D14 version
Instruction Type /4100U Coaxial D14 version Available lengths:, 500 mm, 800 mm, 1000 mm, 1200 mm, 1500 mm, 1700 mm, 2200 mm M84H0030_1 U, 19.2 in. U, 30 in. U, 45 in. U, 55 in. U, 65 in. U, 85 in. Push
More informationSITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43
Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More information2291 Guided Wave Radar Level Transmitter
2291 Guided Wave Radar Level Transmitter Product description / Function The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids,
More informationTEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions
Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The
More informationOPTIFLEX 1100 C Handbook
OPTIFLEX 1100 C Handbook Guided Radar (TDR) Level Meter Continuous level measurement of liquids and solids KROHNE : IMPRINT ::::::::::::::::::::::::::::::::::::::: All rights reserved. It is prohibited
More informationOPTIFLEX 2200 C/F Technical Datasheet
OPTIFLEX 2200 C/F Technical Datasheet Guided Radar (TDR) Level Transmitter for storage and process applications Modular design of housing and sensor ensures suitability for a variety of mounting positions
More informationGuided Wave Radar Level Meter
Guided Wave Radar Level Meter Guided Wave Radar Level Meter Instruction 1. Product Description 1.1 principle of measurement Guided Wave Radar is the measuring instruments that based on the time travel
More informationCapacitance Level Measurement Electronic insert FEC 12
Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation
More informationGuided Radar (TDR) Level Transmitter for storage and process applications
OPTIFLEX 2200 C/F Technical Datasheet Guided Radar (TDR) Level Transmitter for storage and process applications Modular design of housing and sensor ensures suitability for a variety of mounting positions
More informationMechanical flow switch for On/Off control
Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationDissolved Oxygen Transmitter
3 YEAR SENSOR WARRANTY 5.4 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. General MJK Oxix s are designed
More informationDissolved Oxygen Transmitter
Data Sheet 3 YE A SEN R WAR SOR RAN TY 5.4 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL:
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full
More informationLevel Measurement Point level measurement - RF Capacitance switches
Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationTFRH Hygienic RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy
More informationPendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationFlow Measurement SITRANS F M
Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate
More informationLevel Measurement silometer FMC 420, FMC 423
Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationLevel Measurement Point level measurement RF Capacitance switches
Siemens AG 2018 Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces,
More informationSignet 2250 Hydrostatic Level Sensor
Signet 2250 Hydrostatic Sensor *32250.090* 32250.090 Rev. A 10/06 English English Safety Instructions 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confi
More informationAbsolute Encoders Multiturn
The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft
More information48x24. Options ORDER NUMBER OF TYPE PFL B
Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationPressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display
Sens Mini-Cube Sens with Easy-to-Read LED Display Industry s smallest, lightest l Both analog bar and digital pressure values are displayed Two independent outputs plus one analog output are available
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationCapacitance Limit Detection nivotester FTC 420/421/422
Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications
ABB MEASUREMENT & ANALYTICS DATA SHEET AZ00 series Zirconia oxygen analyzer for small boiler applications AZ 00 SE RIE S Z I RCON I A OX YG EN ANALY ZE R FOR SMALL BOILE R APPLIC ATIONS DS/AZ00-E N RE
More informationGRUNDFOS alldos product information. The solution for complex dosing tasks
GRUNDFOS alldos product information The solution for complex dosing tasks Measurements Measurements a h d Electric actuator b Pneumatic actuator g e Ø 9mm k f i m 1 m 2 k j c n l 1 l 2 DMH model Measurements
More informationPanel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features
NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description
More informationFLOMAT Electromagnetic Insertion Flowmeter
LOMAT Electromagnetic Insertion lowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction or use in large diameter pipes or open channels as an
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More informationMaterial: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More informationDMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationFlow Measurement SITRANS F M
Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationOperating Instructions 09/2013
Guided Wave Radar SITRANS LG250 4 20 ma/hart - two-wire Operating Instructions 09/2013 2 SITRANS LG250 - Operating Instructions PBD-51041047 Contents 1 About this document 1.1 Function... 5 1.2 Target
More informationDMP 331i / DMP 333i LMP 331 i
DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma
More informationRIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values
Technical Information RIA46 Field meter Digital field meter with control unit for monitoring and visualizing analog measured values Application Process recording and supervision Process control Signal
More informationFIELD MOUNTED RATE TOTALISER MODEL 202D
FIELD MOUNTED RATE TOTALISER MODEL 202D 16 June 2003 Introduction 1 1. INTRODUCTION The Model 202Di Rate Totaliser is a microprocessor based instrument which accepts a frequency or pulse input from
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationFilters for Power Lines (Low Leakage Current)
Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures
More informationInductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151
Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog
More informationFTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process
FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]
More informationLevel Measurement Continuous level measurement - Capacitance transmitters
Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationTECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT
RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense
More informationWeekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N
Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control
More informationCAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry
CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001
More informationHow to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil
Integrated Display Type Flow rate range 0 2 5 Symbol 0 02 03 0 Specifications ow Order PFA7 0 0 27 0l/min 5 l/min 0 00l/min 20 200l/min 0l/min Port size /8 / 3/8 /2 Model Measured fluid Detection type
More informationMaterial: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More informationDS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection
with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges
More informationLinear flow control with actuator IFC
Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20
More information7 Lighting Technology
7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection
More informationDATA SHEET Panorama Rudder Indicator, TRI-2
DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive
More informationStandard RS232 RS ma
1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision
More informationOrdering Information. Self-Powered Tachometer H7ER. Subminiature Tachometers With Improved Appearance and Features. H Large display with 8.
R Self-Powered Tachometer Subminiature Tachometers With Improved Appearance and Features H Large display with 8.6 mm (0.338 in) height H Available with backlit LCD H Revolutions displayed up to five digits
More informationMetric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar
Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series U 5-Point NIST Traceable
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationEx td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread
I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem
More informationRIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values
Technical Information RIA45 Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values Application Plant and apparatus engineering and construction Control
More informationLinear flow controls VFC Linear flow controls with actuator IFC
Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or
More informationHygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C
Hygrotest 600 Instruction manual en WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C Contents Introduction...2 Handling instructions...3 Dimensions of measuring instrument...3
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSmart-Encoder : Optical Incremental
1. Introduction The Smart-Encoder effectively eliminates multiple encoder part numbers by bringing intelligence and security to its design. In seconds, a four-digit LED display with two push-buttons enables
More informationTUC: Universal thermostat
Product data sheet 3.1 21.700 TUC: Universal thermostat How energy efficiency is improved Control, monitoring and limiting according to needs and with no auxiliary energy. Features Regulates and monitors
More informationRK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationRoof-mounted Blue e+ cooling unit Integration solution VX25
Roof-mounted Blue e+ cooling unit Integration solution VX25 Ease of use Intuitive operation via touch display Integration solution VX25 and Blue e+ Cooling unit with 1.3 kw and Blue e+ technology with
More informationCenturion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series.
Sultan Sonar Manual Rev 1.0 A Higher Level of Performance Manual Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com Table of Contents Contents Overview 3 Principle
More informationFTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process
FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]
More informationModel # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red
Datasheet Large Multicolor that Alternates Between Active Inputs Bright, uniform indicator light Alternates between colors when multiple inputs are active Models are available with up to five colors in
More informationPressure transmitter COMPACT IO-Link,
Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationFLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids
Flowmeters Instrumentation for fluids Series FLOMT FLOMT Electromagnetic Insertion Flowmeter: Introduction For use in large diameter pipes or open channels as an economical solution for liquid metering.
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.
Siemens G 2009 Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits
More informationUser Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:
User Manual M1 Thermocouple type K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 27 mm without plug-in
More informationwww.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~
More informationInstruction Manual. Universal Flow Controller Model 261 / 261-EC-01
Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical
More informationSensor technologies Proximity sensors Series ST4. Brochure
Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with
More informationSINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd
SINGLE ZONE CLIMATE ZONING SYSTEM Technical Manual Polyaire Pty Ltd 11-13 White Road GEPPS CROSS South Australia, 5094 Tel: (08) 8349 8466 Fax: (08) 8349 8446 www.polyaire.com.au CONTENTS Features 1 Application
More informationMicro-Machined Silicon Transducers
Micro-Machined Silicon Transducers wet/wet differential Pressure Models mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series Standard
More informationLPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06
LPUM - Local Power Unit General Product Data Sheet January 2013 SD 1520-0E06 TM LPUM - Local Power Unit January 2013 Description The LPUM - (Local Power Unit) - is an integrated electro-hydraulic system
More informationOperating Instructions
Operating Instructions LEVEL TRANSMITTER 8188 4 20 ma/hart two-wire Rod and cable probe 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbols used... 4 2 For your
More informationEA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS
EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION The Eltra singleturn Pro bus encoder series (Identi cation Number 0x0599) is complying to the Pro bus DP standard as described on the European Standard
More informationOperating Instructions 09/2013
Guided Wave Radar SITRANS LG260 4 20 ma/hart two-wire Operating Instructions 09/2013 2 SITRANS LG260 - Operating Instructions PBD-51041057 Contents 1 About this document 1.1 Function... 5 1.2 Target group...
More informationSelection matrix for electronic pressure switches
Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationSITRANS F M. Transmitter MAG 5000/6000 4/33
Siemens AG 2011 Flow Measurement Overview Design The transmitter is designed as either IP67 NEMA X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack
More information