PORA ELECTRIC MACHINERY CO.,LTD. Setting manual Rev 2.1. Digital Strip Position Amplifier PR-DPA ora.c om

Size: px
Start display at page:

Download "PORA ELECTRIC MACHINERY CO.,LTD. Setting manual Rev 2.1. Digital Strip Position Amplifier PR-DPA ora.c om"

Transcription

1 PORA ELECTRIC MACHINERY CO.,LTD. ora.c om TH HE BE ES ST QU UA AL LT LI IT TY AN ND TR RU US ST Setting manual Rev 2.1 Digital Strip Position Amplifier

2

3 Digital Strip Position Amplifier CONTENTS Product s Features and Notice 04 Chapter 1 _ Before Using the Product Exterior Dimension 6 2. Installation and Wiring 6 3. Connection of the Terminal Block 7 4. Description of the Control Panel Specifications of the Product External Connection Diagram 13 Chapter 2 _ Display Initial Screen 14 CONTENTS 2. Basic Screen Screen of Indicating Alarms Setting Menu Screen 16 Chapter 3 _ Setting 1. Setting of the Basic Menu Setting of the Parameter Menu 20 Chapter 4 _ Other Functions & Setting 1. Test Mode Check of the Interface Operation 40 Chapter 5 _ Abnormality Check Check of Abnormal Alarms Check of Controller s Abnormality 41

4 Digital Strip Position Amplifier Product s Features and Notice (Be sure to read this before using the product) is a high-end CPC/EPC controller with a high-performance CPU. It is compatible with all the CPC/EPC sensors from our company including inductive-type and infrared-type sensors, and it can construct an automatic control system by combining a servo hydraulic unit. It adds a stagger function, which is difficult to implement by the existing analog computing method, and various setting functions to provide convenient working environment. - Please check the product for defects, and whether the packing list and the product match. - For this product s performance and safe use, use it after thoroughly understanding the following instructions. In particular, do not use this equipment for other purpose, and do not modify it arbitrarily. Product s Features Large-screen Display It uses a 5-inch large-size display to indicate the maximum 13 lines of information at a time, so that you can recognize each parameter s setting value, output signals and current operating conditions of the controller at a glance. Various Control Functions CPC control, EPC control, and stagger control functions Precise Control It is equipped with a high-performance 32-bit microprocessor to support sensor s 100% resolution, and it controls the strip precisely by processing operations quickly. Automatic Gain Control Function It supports the gain control automatically depending on the line speed. Function to Save the Strip s Initial Position When a strip is entered initially, it is automatically moved to the position being saved. Communication with RS-232 or USB The PLC environment can be built with RS-232 or USB, or all functions can be controlled remotely with a PC. Option Functions When a controller cannot be installed, a dedicated remote controller can be added to control all functions remotely. 4 PORA ELECTRIC MACHINERY CO.,LTD.

5 Precautions for Installation - Maintain the right vertical and horizontal angles of the product for installation. - Install the product in a place devoid of vibration, shock, high temperature or humidity, direct sunlight, much dust,or air containing much salt or ions. - Do not install the product within the vicinity of inflammable gases or steam or dust. - Wire the product as provided in the following drawings and check if all cables are properly connected. - Ensure the earthing terminal is correctly grounded. - Ensure the product is detached from the power supply cables or the cables with much electrical noise. Warning For the installation and wiring of the controller, completely isolate it from the external power supply. Failure to do so may result in an electrical shock or damage to the controller. Warning Use anti-explosive products where there are high risks of inflammation or explosion. Failure to do so may result in a fire or explosion. Use the anti-explosive products suitable to the given conditions. Precaution Check the surrounding environment. Do not install the controller where it can be exposed to excessive dust, conductive dust, corrosive gases, high temperature or rainy wind. It also should not be installed in the places susceptible to vibrations or shocks. Failure to do so may result in damages to, or malfunctioning or lowered performance of the controller. Precautions for Use - Unwarranted operation of the controller may cause the defects of the object materials. - Pora shall NOT be responsible for any damages to the controller caused by such operations. PORA ELECTRIC MACHINERY CO.,LTD. 5

6 Digital Strip Position Amplifier Before Using the Product 1. Exterior Dimension Cutting Dimension 2. Installation and Wiring The controller can be installed by various methods as below. Stationary Scheme When installing at a fixed location, keep the controller horizontal to place it. Panel Mount Scheme When installing on a panel, open the door and use screws to fasten the controller tightly on the panel. It is recommended to install the controller on a place where is convenient to use and easy to maintain and repair. 6 PORA ELECTRIC MACHINERY CO.,LTD.

7 3. Connection of the Terminal Block 1) Terminal Block Array TB5 TB1-1 TB1-2 TB1-3 TB1-4 TB1-5 TB1-6 TB1-7 TB1-8 TB1-9 TB TB1 2 TB2-1 TB2-2 TB2-3 TB2-4 TB2-5 TB2-6 TB2-7 TB2-8 3 TB TB3-1 TB3-2 TB3-3 TB3-4 TB3-5 TB3-6 TB3-7 TB3-8 TB3-9 TB3-10 TB3-11 TB3-12 TB3-13 TB3-14 TB3-15 TB6 TB TB6 3 TB4-1 TB4-2 TB4-3 TB4-4 TB4-5 TB4-6 TB4-7 TB4-8 TB4-9 TB4-10 TB4-11 TB4-12 TB4-13 TB4-14 TB4-15 TB (1) TB1 Terminal Array (2) TB2 Terminal Array 1 IN1 Sensor-1 input + 1 IN1 No plate input + TB1-1 2 IN2 Sensor-1 input - TB2-1 2 IN2 No plate input- UnusedOpen 3 IN3 Shield 3 IN3 Shield 1 IN4 Sensor-2 input + 1 IN4 Lamp-1 out input + TB1-2 2 IN5 Sensor-2 input - TB2-2 2 IN5 Lamp-1 out inout- UnusedClose 3 IN6 Shield 3 IN6 Shield 1 IN7-1 IN7 Lamp-2 out input + TB1-3 2 IN8 - TB2-3 2 IN8 Lamp-2 out input- UnusedClose 3 IN9-3 IN9 Shield 1 IN10-1 IN10 Rollout input + TB1-4 2 IN11 - TB2-4 2 IN11 Rollout input- UnusedOpen 3 IN12-3 IN12 Shield TB1-5 TB1-6 TB1-7 TB1-8 TB1-9 1 IN13 Position transmitter + 2 IN14 Position transmitter signal 1 IN15 Position transmitter - Linear probe signal (4~20madc) 2 IN16 Shield Linear probe (a gnd) 1 IN17 Analog shift input + 2 IN18 Analog shift input- 3 IN19 Shield 1 IN20 Line speed input + 2 IN21 Line speed input- 3 IN22 Shield 1 IN23-2 IN24-3 IN25 - TB2-5 TB2-6 TB2-7 TB2-8 1 OUT13 Control output + 2 OUT14 Control output- 3 OUT15 Shield 1 OUT16 Strip deviation output + (Cascade deviation output +) 2 OUT17 Strip deviation output- (Cascade deviation output-) 3 OUT18 Shield 1 OUT19 Cylinder position output + (Cascade deviation output +) 2 OUT20 Cylinder position output- (Cascade deviation output-) 3 OUT21 Shield 1 OUT22 Shift amount output + (Cascade deviation output +) 2 OUT23 Shift amount output- (Cascade deviation output-) ±10Vdc ±300mAdc ±5Vdc ±5Vdc ±5Vdc 3 OUT24 Shield PORA ELECTRIC MACHINERY CO.,LTD. 7

8 Digital Strip Position Amplifier (3) TB3 Terminal Array (4) TB4 Terminal Array TB3-1 TB3-2 TB3-3 TB3-4 TB3-5 TB3-6 TB3-7 TB3-8 TB3-9 TB3-10 TB3-11 TB3-12 TB3-13 TB3-14 TB IN1 AUTO 2 IN2 MANUAL 1 IN3 CENTER 2 IN4 AUTO START 1 IN5 2 IN6 LEFT 1 IN7 RIGHT 2 IN8 SHIFT + 1 IN9 SHIFT - 2 IN10 STAGGER ON 1 IN11 INTEGRAL HOLD 2 IN12 INTEGRAL RESET 1 IN13 2 IN14 FILTER CLOGGING 1 IN15 OIL PRESSURE LOW 2 IN16 OIL TEMPERATURE HIGH 1 IN17 OIL LEVEL LOW 2 IN18 1 IN19 CPC/EPC CHANGE 2 IN20 STAGGER SELECT-1 1 IN21 STAGGER SELECT-2 2 IN22 1 IN23 2 IN24 PLG Signal 1 IN25 PLG Signal (Vcc) 2 IN26 PLG Signal (Gnd) 1 IN27 Output 24V+ (Com) 2 IN28 Output 24V+ (Com) 1 IN29 Output 24V- (Com) 2 IN30 Output 24V- (Com) 3 IN31 Output 24V- (Com) TB4-1 TB4-2 TB4-3 TB4-4 TB4-5 TB4-6 TB4-7 TB4-8 TB4-9 TB4-10 TB4-11 TB4-12 TB4-13 TB4-14 TB OUT1 HEALTHY 2 OUT2 AUTO CONTROL ACTIVE 1 OUT3 REMOTE 2 OUT4 CENTERING COMPLETE 1 OUT5 LAMP-1 OUT 2 OUT6 LAMP-2 OUT 1 OUT7 2 OUT8 ROLLOUT 1 OUT9 NO PLATE 2 OUT10 DEVIATION EXCESSIVE 1 OUT11 OIL PRESSURE LOW 2 OUT12 OIL TEMPERATURE HIGH 1 OUT13 OIL LEVEL LOW 2 OUT14 AUTO MODE 1 OUT15 FILTER CLOGGING 2 OUT16 ALARM BATCH 1 OUT17 MANUAL MODE 2 OUT18 CENTERING MODE 1 OUT19 NOT ALARM 2 OUT20 1 OUT21 2 OUT22 1 OUT23 2 OUT24 1 OUT25 2 OUT26 1 OUT27 Output 24V- (Com) 2 OUT28 Output 24V- (Com) 1 OUT29 2 OUT30 (5) TB5 Hydraulic Unit Connection Terminal (6) TB6 Power Connection Terminal TB5 1 SOLENOID POWER + (In) 2 SOLENOID POWER- (In) 3 SOLENOID POWER + (Out) 4 SOLENOID POWER- (Out) TB5 1 AC POWER 2 AC POWER 3 Earth Caution Check power input and wiring Wrong connections of power terminals (be also careful of the sequence that normal loads use power), contacts of DC input/output wires and power wires, and short circuits of output wires etc. may be a cause of serious damages. 8 PORA ELECTRIC MACHINERY CO.,LTD.

9 2) Connection of Sensors Because the wiring method is different depending on the sensor s scheme, connect it correctly as below. Caution Check the connecting terminals for each type of sensors The color of connecting terminals is different for each type of sensors. Because there may be risks of malfunctions and damages, be sure to check the connecting terminals above and connect them suitable to the color. (1) CPC Sensor TB1-1 TB (2) EPC Sensor TB1-1 TB PORA ELECTRIC MACHINERY CO.,LTD. 9

10 Digital Strip Position Amplifier 4. Description of the Control Panel Front Control Panel 2. Status Indication LED 1. Status Display Window CPC P RP CONTROL OUTPUT V R P DA STRIP DEVIATION mm D R P CYLINDER POSITION mm AR STAGGER LEVEL mm LINE SPEED mpm P D LINE SIGMA mm A D-SFT +00.0mm A-SFT mm A AR ALARM ROLL OUT LARGE DEV HEALTHY ALARM REMOTE LOCAL AUTO MANU CENTER ESC CLEAR ENTER 3. REMOTE Button 4. LOCAL Button 5. AUTO (ESC) Button 6. MANU (CLEAR) Button 7. CENTER (ENTER) Button 8. LEFT, RIGHT Button PORA P RA Electric Machinery LEFT RIGHT DIGITAL STRIP POSITION AMPLIFIER + - UP DOWN 9. SHIFT (UP,DOWN) Button SHIFT Inside Control Panel 15. USB Connection Terminal 14. DITHER-OFFSET Control Volume 13. DITHER-GAIN Control Volume 12. RS232 Connection Terminal 11. Setting Menu Button 10. Setting Menu Selection Switch 16. Display Backlight Control Volume 17. Power Switch 10 PORA ELECTRIC MACHINERY CO.,LTD.

11 Button Current status and working conditions are indicated. Description CPC/EPC Mode Indication Control Output CPC 1 Status Display Window Strip Deviation Cylinder Position Stagger Level Line Speed Line Sigma Digital Shift Alarm Indication CONTROL OUTPUT +0.00V STRIP DEVIATION mm CYLINDER POSITION mm STAGGER LEVEL mm LINE SPEED 0000mpm LINE SIGMA +00.0mm D-SFT +00.0mm A-SFT +00.0mm ALARM ROLL OUT LARGE DEV Analog Shift The backlight is turned on when manipulating a button, and it is automatically turned off when not operating for 10 minutes. Indicates normal working conditions and alarms. 2 Status Indication LED Indication of normal working conditions Indication of alarms HEALTHY ALARM 3 REMOTE Button Changes into the remote control mode, and the dedicated remote can be used to control remotely (In the remote control mode, operation of the display buttons becomes the lock condition.) 4 LOCAL Button Changes into the front panel control mode. 5 AUTO (ESC) Button Changes into the auto mode (cancel button in the setting menu mode.) 6 MANU (CLEAR) Button Changes into the manual mode. 7 CENTER (ENTER) Button It places with a guide as the center (confirm button in the setting menu mode.) 8 LEFT, RIGHT Button Moves a reel or guide to the left and right. 9 SHIFT (UP,DOWN) Button Moves a strip to the left and right. 10 Setting Menu Selection Switch It is a switch to set as the supervisor mode 11 Setting Menu Button Changes into the setting mode. 12 RS232 Connection Terminal It can connect with a PC and external devices. 13 DITHER-GAIN Control Volume Controls a gain value of the dither function (function to prevent valves from fixing.) 14 DITHER-OFFSET Control Volume Controls an offset value of the dither function (function to prevent valves from fixing.) 15 USB Connection Terminal It can connect with a PC and external devices. 16 Display Backlight Control Volume Controls brightness of the display backlight. 17 Power Switch It is the power switch. PORA ELECTRIC MACHINERY CO.,LTD. 11

12 Digital Strip Position Amplifier 5. Specifications of the Product Display Operation mode Input Output Alarm Communication Power Power consumption Sensor input Outside input I/F signal Position Transmitter Line speed PLG signal Control signal Shift amount Cylinder position Strip deviation Stagger function System normal operation detection SPECIFICATIONS AUTO / MANU / CENTER operation status Check whether there is a strip of not Strip deviation Strip error excessive Pressure of the hydraulic unit low Temperature of the hydraulic unit high Hydraulic fluid of hydraulic unit not enough 5.1 inch large screen LCD display CPC mode / EPC mode -5~5Vdc, 0~5Vdc, 4~20mAdc ±10Vdc 0~2kΩ, 4~20mAdc 0~10Vdc or 4~20mAdc Pulse signal (24Vdc) Max.freq. 1kHz, NPN Type USB, RS-232C output ( It is an option.) AC110V~AC220V 50/60Hz 100VA Operation Temperature -20~60 Weight Protection structure 6kg IP40 equivalent ±300mAdc load 20Ω (max) ±5Vdc load 1kΩ (min) Stores 4 types of setup values Transister output(photocoupler insulation) Open collector output +24Vdc/100mAdc 12 PORA ELECTRIC MACHINERY CO.,LTD.

13 13 PORA ELECTRIC MACHINERY CO.,LTD. 6. External Connection Diagram

14 Digital Strip Position Amplifier Display 1. Initial Screen It is the initial screen when power is applied, which indicates a software version of the product. SELF CHECK NOW Basic Screen It is the basic operating screen, which indicates various information and alarms. 1CPC/EPC Mode Indication 2Control Output 3Strip Deviation 4Cylinder Position 5Stagger Level 6Line Speed 7Line Sigma 8Digital Shift 9Alarm Indication CPC CONTROL OUTPUT +0.00V STRIP DEVIATION mm CYLINDER POSITION mm STAGGER LEVEL mm LINE SPEED 0000mpm LINE SIGMA +00.0mm D-SFT +00.0mm A-SFT +00.0mm ALARM ROLL OUT LARGE DEV 10Analog Shift 1Indication of CPC/EPC Mode 2Control Output 3Strip Deviation 4Cylinder Position 5Stagger Level 6Line Speed 7Line Sigma 8Digital Shift 9Alarm Indication 10Analog Shift Description Indicates CPC / EPC. Indicates current output voltages for controlling the hydraulic unit. MAX ± 9.99V (±300mA) Indicates a distance from the line s center to the strip s center as an CPC Mode absolute value. Indicates a distance from the base position to the strip edge as an EPC Mode absolute value. Indicates the cylinder position. Indicates a moving value of the stagger position. Indicates the operating speed. Indicates a sigma value of the line while the PI control is operating. Indicates internal digital shift values. Indicates errors and danger alarms. Indicates external analog shift values. 14 PORA ELECTRIC MACHINERY CO.,LTD.

15 3. Screen of Indicating Alarms It describes a type of alarms. CPC CONTROL OUTPUT +0.00V STRIP DEVIATION mm CYLINDER POSITION mm STAGGER LEVEL mm LINE SPEED 0000mpm LINE SIGMA +00.0mm D-SFT +00.0mm A-SFT +00.0mm ALARM ROLL OUT LARGE DEV 1) No Plate It is indicated when there is no plate ALARM NOTHING PLATE (Terminal block TB2-1-1 ~ TB2-1-2) 6) Low Oil Amount It is indicated when the hydraulic unit s oil amount is low ALARM OIL LEVEL (Terminal block TB3-9-1) 2) LAMP1 Failure It is indicated when the LAMP1 connection is failed ALARM LAMP1 FAIL (Terminal block TB2-2-1 ~ TB2-2-2) 3) LAMP2 Failure It is indicated when the LAMP2 connection is failed ALARM LAMP2 FAIL (Terminal block TB2-3-1 ~ TB2-3-2) 7) Roll Out It is indicated when a strip is deviated from the roll ALARM ROLL OUT (Terminal block TB2-4-1 ~ TB2-4-2) (Or the value is set in the parameter.) 8) Filter Blockage The alarm is indicated when the hydraulic unit s filter is blocked ALARM FILTER CLOG (Terminal block TB3-7-2) 4) Low Oil Pressure It is indicated when the hydraulic unit s pressure is low ALARM OIL PRESS (Terminal block TB3-8-1) 9) Excessive Deviation Value It is indicated when an established deviation value is exceeded ALARM LAGE DEV (The value is set in the parameter.) 5) High Oil Temperature It is indicated when the hydraulic unit s oil temperature is high ALARM OIL TEMP (Terminal block TB3-8-2) PORA ELECTRIC MACHINERY CO.,LTD. 15

16 Digital Strip Position Amplifier 4. Setting Menu Screen When pressing the [SETUP Button] on the inside control panel for 3 seconds, it changes into the setting menu, and can set the basic and detailed items. ==DATA SET== 1.EPC/CPC SELECT 2.SENSOR TYPE 3.PARAMETER SET 4.I/F CHECK 5.EPC/CPC CHANGE 6.START OPERATION 7.EXIT CPC AWIR INT LOC 1. EPC/CPC SELECT CPC / EPC 2. SENSOR TYPE AWIR / SMI 1. SENSOR ADJ 2. CYLINDER DATA 3. CENTERING DATA 3. PARAMETER SET 4. STAGGER DATA 5. MANUAL CONTROL DATA 1. LENGTH CH1 0~2000.0mm 2. LENGTH CH2 0~2000.0mm 3. ZERO CH1 CH2 Automatic Setting 4. SPAN CH1 (00000~16384) CH2 5. BIAS ~ +99.9mm 6. POLARITY 0 or 1 7. MEMORY ON / OFF 1. CYLINDER STROKE 0000~2000mm 2. ZERO READ (BCD) 3. SPAN READ (BCD) Automatic Setting (00000~16384) 4. POLARITY 0 or 1 5. MEMORY ON / OFF 1. POSI. READ(BCD) Automatic Setting (00000~16384) 2. CENT COMP 0~99.9mm 3. CENT COMP TIME 0.0~9.9SEC 4. GAIN 0~9.99V/mm 5. CYL. CENTERING 0 (use automatic centering) or 1 (no use automatic centering) 1. MANDRILL PULSE 0~9999PLS/R 2. RESOLUTION 0~20R/R 1. STAGGER1 A1 COUNT 0000~ STAGGER1 A2 COUNT 0000~ STAGGER1 LEVEL 000~999mm 4. STAGGER2 A1 COUNT 0000~ STAGGER2 A2 COUNT 0000~ STAGGER2 LEVEL 000~999mm 7. STAGGER3 A1 COUNT 0000~ STAGGER3 A2 COUNT 0000~ STAGGER3 LEVEL 000~999mm 10. STAGGER4 A1 COUNT 0000~ STAGGER4 A2 COUNT 0000~ STAGGER4 LEVEL 000~999mm 1. MANUAL LEFT 0~9.99V 2. MANUAL RIGHT 0~9.99V 3. POLARITY 0 or 1 16 PORA ELECTRIC MACHINERY CO.,LTD.

17 1. I / P / PI SELECT I / P / PI 6. I-P-PI DATA 2. P GAIN 0~300% 3. I TIME 0~99.9SEC 4. I HOLD 0~99.9mm 1. GAIN 0V~9.99V/mm 7. CONTROL OUTPUT 2. LIMIT 0~9.99V 3. DEAD ZONE 0.0~9.9mm 1. DEVIATION (5V) 0~2000.0mm 2. DEV. POLARITY 0 or 1 8. ANALOG OUTPUT 3. CYLINDER (5V) 0~2000.0mm 4. CYL. POLARITY 0 or 1 5. SHIFT (5V) 0~999.9mm 6. SHIFT POLARITY 0 or 1 1. SHIFT STEP 9.9mm 2. SHIFT CONTROL POL. 0 or 1 3. SHIFT INPUT MODE SINGLE or BOTH 4. SHIFT LIMIT 0~99.9mm 9. ETC 5. DITHER ON or OFF 6. DITHER FREQUENC 50Hz or 100Hz 7. LARGE DEVIATION 999mm 8. ROLL OUT CH_A 999mm 9. ROLL OUT CH_B 999mm 1. LINE SPEED ZERO 0000~9999mpm 2. LINE SPEED SPAN 0000~9999mpm 3. ZERO (V) 0~99V 1. LINE SPEED 4. SPAN (V) 0~99V 5. I HOLD SPEED 0000~9999mpm 3. PARAMETER SET 6. BREAK POINT X 0000~9999mpm 7. BREAK POINT Y 0~99% 8. B.P POLARITY 0 or 1 1. SHIFT LENGTH 0~999.9mm 2. ZERO READ (BCD) Automatic Setting (00000~16384) 3. SPAN READ (BCD) Automatic Setting (00000~16384) 2. ANALOG SHIFT 4. CENTER READ (BCD) Automatic Setting (00000~16384) 5. ANALOG LIMIT 999.9mm 6. CONTROL POL 0 or 1 7. ANA. CENTERING 0 (use automatic centering) or 1 (no use automatic centering) 1. DEV. POINT X1 0~99% 2. OUT. POINT Y1 0~99% 3. NONLINEAR 3. DEV. POINT X2 0~99% 4. OUT. POINT X2 0~99% 5. DEV. POINT X3 0~99% 6. OUT. POINT X3 0~99% 1. SHIFT SELECT DIG+ANA / ANALOG / DIGITAL / OFF 2. SHIFT MEMORY ON / OFF 3. LINE SPEED ON / OFF 4. USER EN/DI & ALARM 4. NOLINEAR ON / OFF SET 5. NO PLATE INPUT USE or UN-USE 6. LAMP1 FAIL INPUT USE or UN-USE 7. LAMP2 FAIL INPUT USE or UN-USE 8. ROLL OUT INPUT USE or UN-USE 1. OUTPUT 0 or 1 2. STRIP DEVIATION 0 or 1 5. DISP POLARITY 3. CYLINDER 0 or 1 4. STAGGER 0 or 1 5. SHIFT 0 or 1 4. I/F CHECK Check data 5. EPC/CPC CHANGE LOC(Local box) / REM(Remote) 6. START OPERATION LOC(Local box) / REM(Remote) 7. EXIT - PORA ELECTRIC MACHINERY CO.,LTD. 17

18 Digital Strip Position Amplifier Setting When pressing the [SETUP Button] on the inside control panel for 3 seconds, it enters into the setting menu. ( The Setting Menu Button is worked only for the MANU mode. Check whether it is the MANU Mode state for entering the setting mode.) CPC CONTROL OUTPUT +0.00V STRIP DEVIATION mm CYLINDER POSITION mm STAGGER LEVEL mm LINE SPEED 0000mpm LINE SIGMA +00.0mm D-SFT +00.0mm A-SFT +00.0mm ALARM ROLL OUT LARGE DEV ==DATA SET== 1.EPC/CPC SELECT 2.SENSOR TYPE 3.PARAMETER SET 4.I/F CHECK 5.EPC/CPC CHANGE 6.START OPERATION 7.EXIT CPC AWIR INT LOC Pressing the [SETUP Button] on the inside control panel for 3 seconds to enter the setting menu. Operating Buttons for Setting the Menu In the MANU mode, use the following keys to move items or to change the setting values. HEALTHY ALARM REMOTE LOCAL CLEAR Button In the menu mode, use the keys below to move items or to change a setting values. ENTER Button It is the confirm button to enter into a selection or to save a setting value. AUTO MANU CENTER ESC Button It cancels to enter or change a setting value, or returns to the previous step. ESC CLEAR ENTER LEFT RIGHT LEFT, RIGHT Button It moves to the left and right, and to change the selected item and the number of digits when changing the setting value. + - UP DOWN UP, DOWN Button It moves the menu item up and down, or to change a setting value. SHIFT 18 PORA ELECTRIC MACHINERY CO.,LTD.

19 1. Setting of the Basic Menu ==DATA SET== 1.EPC/CPC SELECT 2.SENSOR TYPE 3.PARAMETER SET 4.I/F CHECK 5.EPC/CPC CHANGE 6.START OPERATION 7.EXIT CPC AWIR INT LOC 1) Set a control mode to be used. Select the 1. EPC/CPC SELECT item to choose a sensor to be used. EPC = It would be selected when carrying out the EPC control. CPC = It would be selected when carrying out the CPC control. 2) Select a sensor to be used. Select the 2. SENSOR TYPE item to choose a sensor to be used. If using the CPC control AWIR = Select if using an infrared type CPC sensor (PR-AW). SMI = Select if using an inductive type CPC sensor (PR-SMI). If using the EPC control AWIR = Select if using an infrared type EPC sensor. 3) Set the control method Select the 5. EPC/CPC CHANGE item to choose a control method to be used. INT = It operates in the local box to control it. EXT = It operates remotely to control it. 4) Set a operating method Select the 6. START OPERATION item to choose an operating method to be used basically when turning power on. LOC = The local box operating method is selected basically when turning power on. REM = The remote operating method is selected basically when turning power on. PORA ELECTRIC MACHINERY CO.,LTD. 19

20 Digital Strip Position Amplifier 2. Setting of the Parameter Menu When pressing the [ENTER Button] in the 3. PARAMETER SET, it is indicated a screen to set parameters. ==DATA SET== 1.EPC/CPC SELECT 2.SENSOR TYPE 3.PARAMETER SET 4.I/F CHECK 5.EPC/CPC CHANGE 6.START OPERATION 7.EXIT CPC AWIR INT LOC ==PARAMETER SET== 1.SENSOR ADJ 2.CYLINDER DATA 3.CENTERING DATA 4.STAGGER DATA 5.MANUAL CONTROL DATA 6.I-P-PI DATA 7.CONTROL OUTPUT 8.ANALOG OUTPUT 9.ETC [NEXT] Pressing the [ENTER Button] in the 2. PARAMETER SET to enter the parameter setting menu. ==PARAMETER SET== 1.LINE SPEED 2.ANALOG SHIFT 3.NONLINEAR 4.USER EN/DI & ALARM SET 5.DISP POLARITY 1) Setting of Sensors When pressing the [ENTER Button] in the 1, SENSOR ADJ., a screen is indicated as below. (1) When Using the CPC Sensor --SENSOR ADJ-- 1.LENGTH CH mm 2.LENGTH CH mm 3.ZERO CH CH SPAN CH CH BIAS +00.0mm 6.POLARITY 0 7.MEMORY OFF 1 Set a detecting range. Select the 1. LENGTH CH1 and 2. LENGTH CH2 items to enter a detecting range (set within 0~2000mm.) (Maximum Width - Minimum Width) = Input Value 2 20 PORA ELECTRIC MACHINERY CO.,LTD.

21 2 Set a zero value. Select the 3. ZERO CH item to load an A/D value with zero state automatically. 3 Set a span value. Select the 4. SPAN item to load an A/D value with zero state automatically. 4 Adjust if there is a mechanical error. If an error is occurred due to a mechanical structure, select the 5. BIAS item to compensate the error. ( In the initial setting, set it as 00.0mm.) 5 Set normal/reverse. In general, set it as a normal direction (Polarity = 0 ). ( After testing, if output values of the left/right sensors are generated reversely, select the 7. POLARITY item to change normal/reverse.) 6 Setting to use the function of storing a strip position. In general, set the memory function as OFF state. If using the memory function, when turning on the 7. MEMORY item to change from the MANU mode to the AUTO mode, the position value of current strip is stored to control the strip based on the position. PORA ELECTRIC MACHINERY CO.,LTD. 21

22 Digital Strip Position Amplifier (2) When Using the EPC Sensor --SENSOR ADJ-- 1.LENGTH mm 2.ZERO READ(BCD) SPAN READ(BCD) BIAS +00.0mm 5.POLARITY 0 6.MEMORY OFF 1 Set a detecting range. Select the 1. LENGTH items to enter a detecting range (set within 0~2000mm.) (Maximum Width - Minimum Width) = Input Value 2 2 Set a zero value. Select the 2. ZERO READ(BCD) item to load an A/D value with zero state automatically. 3 Set a span value. Select the 3. SPAN READ(BCD) item to load an A/D value with span state automatically. 4 Adjust if there is a mechanical error. If an error is occurred due to a mechanical structure, select the 4. BIAS item to compensate the error. ( In the initial setting, set it as 00.0mm.) 5 Set normal/reverse. In general, set it as a normal direction (Polarity = 0 ). (After testing, if output values of the left/right sensors are generated reversely, select the 5. POLARITY item to change normal/reverse.) 6 Setting to use the function of storing a strip position. In general, set the memory function as OFF state. If using the memory function, when turning ON the 6. MEMORY item to change from the MANU mode to the AUTO mode, the position value of current strip is stored to control the strip based on the position. 22 PORA ELECTRIC MACHINERY CO.,LTD.

23 2. Setting of the Cylinder ( 2. CYLINDER DATA ) When pressing the [ENTER Button] in the 2. CYLINDER DATA, a screen is indicated as below. --CYLINDER-- 1.CYLINDER STROKE mm 2.ZERO READ (BCD) SPAN READ (BCD) POLARITY 0 5.MEMORY OFF 1) Set a range of the cylinder stroke. Select the 1. CYLINDER STROKE item to set the maximum moving distance of cylinder. (The setting range is 0~2000mm.) 2) Set a ZERO value of the cylinder. Select the 2. ZERO READ (BCD) item to set a ZERO value of the cylinder automatically. It is automatically set by using an A/D value. 3) Set a SPAN value of the cylinder. Select 3. SPAN READ (BCD) item to set a span value of the cylinder automatically. It is automatically set by using an A/D value. 4) Change output values of the cylinder In general, it is set as the normal direction (Polarity = 0 ). (After testing, if output values of the cylinder are generated reversely, select 4. POLARITY item to change it.) 5) Cylinder memory function. Set the memory function as OFF state. PORA ELECTRIC MACHINERY CO.,LTD. 23

24 Digital Strip Position Amplifier 3. Setting of the Centering Data ( 3. CENTERING DATA ) When pressing the [ENTER Button] in the 3. CENTERING DATA, a screen is indicated as below. --CENTERING-- 1.POSI. READ(BCD) CENT COMP 01.0mm 3.CENT COMP TIME 1.0SEC 4.GAIN 3.00V/mm 5.CYL. CENTERING 0 1) Set the center position of a cylinder. If selecting the 1. POSI. READ (BCD) item, the center position of a cylinder is set automatically. 2) Set a center range of the cylinder. For a safe operation, select the 2. CENT COMP item to set a center range of the cylinder. 3) Set a time to check a center of the cylinder. Select the 3. CENT COMP TIME item to set a stop time for checking whether it is a center of the cylinder. 4) Set a GAIN value of the cylinder. Select 4. GAIN item to set a GAIN value of the cylinder. 5) Set a method of setting the cylinder s center position. Select 5. CYL. CENTERING item to establish a setting method of the cylinder center. 0 = Set the cylinder s central position according to the setting of POSI and READ. 1 = Set the cylinder s central position based on ZERO and SPAN values. ( 1. POSI. READ (BCD) setting is not required.) 24 PORA ELECTRIC MACHINERY CO.,LTD.

25 4. Setting of the Stagger ( 4. STAGGER DATA ) When pressing the [ENTER Button] in the 4. STAGGER DATA, a screen is indicated as below. --STAGGER-- 1.MANDRILL PULSE 2.RESOLUTION 3.[NEXT] 0020PLS/R 01R/R 1. STAGGER1 A1 COUNT A2 COUNT LEVEL 000mm 4. STAGGER2 A1 COUNT A2 COUNT LEVEL 000mm 7. STAGGER3 A1 COUNT A2 COUNT LEVEL 000mm 10. STAGGER4 A1 COUNT A2 COUNT LEVEL 000mm It can move to the next page by pressing the ENTER button in the [NEXT]. If you want to use the stagger function, after connecting the proximity sensor, the ON signal terminal of the stagger should be connected with the Com terminal. Connecting of the Proximity Sensor The proximity sensor uses the NPN type, install it as below and connect with the terminal block. Install a detecting pin of metallic material on the rotating axis so that the proximity sensor can detect the number of revolutions of the roller. Connecting of the Stagger ON Signal with the Com If connecting the Stagger On terminal with the Com, the stagger becomes an ON state. PORA ELECTRIC MACHINERY CO.,LTD. 25

26 Digital Strip Position Amplifier 1) Set the MANDRILL pulse. Select the 1. MANDRILL PULSE item to set the number of pulses for moving the stagger by a step. ex) If setting the MANDRILL pulses as 5, a pulse would be generated when the winder rotates 5 times. Proximity Sensor Signal Stagger Triggering Pulse 3) Set a resolution of the stagger. A resolution can be minutely adjusted by selecting the 2. RESOLUTION item to set it. The resolution can be set within a range from 1/1 to 1/20 proportional to the (MANDRILL pulses / the number of winder revolutions). Set a value of the 1. MANDRILL PULSE to be a multiple of the setting value for the stagger resolution. (If the 1. MANDRILL PULSE value is not a multiple of the setting value for the stagger resolution, an error is occurred as below.) << INPUT ERROR!!! >> When setting the resolution as 1 Outputs directly proportional to the established MANDRILL pulse value and the signal setting value Cross section of the strip on the winder MANDRILL Pulse Resolution When setting the resolution as 2 The resolution is doubled to decrease the moving distance per a pulse by 1/2, and the MANDRILL pulse value becomes as 1/2 to compensate the number of revolutions. MANDRILL Pulse 2 Resolution 2 When setting the resolution as 4 The resolution is multiplied by 4 to decrease the moving distance per a pulse by 1/4, and the MANDRILL pulse value becomes as 1/4 to compensate the number of revolutions. MANDRILL Pulse 4 Resolution 4 26 PORA ELECTRIC MACHINERY CO.,LTD.

27 2) Set the stagger signal. Select the 3. [NEXT] item to set the signal. A working signal of the stagger can be set, and the setting data can be changed by an external switch after storing the signal data up to 4 types. A1 - It sets a time to reach the highest point of a signal. A2 - It sets a time to keep the highest point of a signal. LEVEL - It adjusts a signal s height. Connecting of the changeover switch for stagger data The stagger data is set as Stagger 1 that is a basic value, and an external switch connection is required for changing into the other data. SW1 SW2 STAGGER DATA SELECT OFF ON OFF OFF OFF ON Use the STAGGER 1 data Use the STAGGER 2 data Use the STAGGER 3 data ON ON Use the STAGGER 4 data Stagger setting example 1) 1.MANDRILL PULSE 2.RESOLUTION 0010PLS/R 01R/R 1. MANDRILL PULSE Set as 10 PLS/R 2. RESOLUTION Set as 1 R/R 1. STAGGER1 A1 COUNT A2 COUNT LEVEL 100mm 1. STAGGER1 A1 COUNT Set as A2 COUNT Set as LEVEL Set as 100mm It moves by 10mm (LEVEL/A1) every 10 rotations as a counter when the tension reel is rotated 10 times, moves 100mm during 100 rotations of A1 s 10 counts (PULSE A1=100 rotations), stops during 50 rotations of A2 s 5 counts (PULSE A2=50 rotations), and then repeats to A1 again. Stagger setting example 2) 1.MANDRILL PULSE 2.RESOLUTION 0005PLS/R 01R/R 1. MANDRILL PULSE Set as 5 PLS/R 2. RESOLUTION Set as 1 R/R 1. STAGGER1 A1 COUNT A2 COUNT LEVEL 200mm 1. STAGGER1 A1 COUNT Set as A2 COUNT Set as 2 3. LEVEL Set as 200mm It moves by 4mm (LEVEL/A1) every 10 rotations as a counter when the tension reel is rotated 5 times, moves 200mm during 250 rotations of A1 s 50 counts (PULSE A1=250 rotations), stops during 10 rotations of A2 s 5 counts (PULSE A2=10 rotations), and then repeats to A1 again. PORA ELECTRIC MACHINERY CO.,LTD. 27

28 Digital Strip Position Amplifier 5. Setting of the Manual Control ( 5. MANUAL CONTROL DATA ) When pressing the [ENTER Button] in the 5. MANUAL CONTROL DATA, a screen is indicated as below. --MANUAL CONTROL-- 1.MANUAL LEFT 5.00V 2.MANUAL RIGHT 5.00V 3.POLARITY 0 1) Set a moving speed of the cylinder. Setting of a speed moving to the left Select 1. MANUAL LEFT item to set a speed of moving the cylinder to the left by the LEFT Button. (A moving speed can be set from 0 to 9.99V, and it is set as 3V in general.) Setting of a speed moving to the right Select 2. MANUAL RIGHT item to set a speed of moving the cylinder to the right by the RIGHT Button. (A moving speed can be set from 0 to 9.99V, and it is set as 3V in general.) 2) Change a moving direction of the cylinder. In general, it is set as the normal direction (Polarity = 0.) (After testing, if the cylinder is moved in the opposite direction, select 3. POLARITY item to change the moving direction.) 28 PORA ELECTRIC MACHINERY CO.,LTD.

29 6. Setting of the Control Mode ( 6. I-P-PI DATA ) When pressing the [ENTER Button] in the 6. I-P-PI DATA, a screen is indicated as below. --I-P-PI DATA-- 1.I/P/PI SELECT P 2.P GAIN 100% 3.I TIME 00.0SEC 4.I HOLD 00.0mm 1) Select a control mode. Select 1. I / P / PI SELECT item to choose a control mode. In general, it sets as the I mode, if it requires a faster control, it selects the P or PI control. I Control Mode = It can do a rapid control based on sensors because it controls by using detected signals and line speed of the sensors. P Control Mode = It can control stably without hunting because it sets the reference ratio by using line speeds of sensors and cylinders. PI Control Mode = It can move by an amount of sigma to the line speed established by using the sigma of sensors and cylinders, and can control it. (Used for a case of offsetting to one side.) 2) Set the P GAIN value. (Used in the P or the PI control mode) It is used in the P and PI control mode, and it can set the ratio of cylinders and sensors by selecting 2. P GAIN item. Ex1) A strip deviation is 10mm, and a setting value is 100% mm = 10mm (The control output is 0V when the cylinder is positioned at 10mm.) 100% Ex2) A strip deviation is 10mm, and a setting value is 50% mm = 20mm (The control output is 0V when the cylinder is positioned at 20mm.) 100% Ex3) A strip deviation is 10mm, and a setting value is 200% mm = 5mm (The control output is 0V when the cylinder is positioned at 5mm.) 100% 3) Set the maximum operating speed. (Used in the PI control mode) In general, it sets as 0 SEC in the I control mode. It is used in the PI control mode, and select the 3. I TIME item to set the maximum operating speed. Input Value for Operating Speed Operating Speed = Established Operating Speed Maximum Operating Speed 4) Setting of the hold range. In general, it sets as 0mm in the I control mode. It is used to set an effective center range in the PI control mode, and select the 4. I HOLD item to set it. The guide becomes a hold condition within the established deviation. PORA ELECTRIC MACHINERY CO.,LTD. 29

30 Digital Strip Position Amplifier 7. Setting of the Control Output ( 7. CONTROL OUTPUT ) When pressing the [ENTER Button] in THE 7. CONTROL OUTPUT, a screen is indicated as below. --CONTROL OUTPUT-- 1.GAIN 1.50V/mm 2.LIMIT 5.00V 3.DEAD ZONE 0.0mm 1) Set a GAIN value. A voltage value per 1mm of strip deviation can be set up to 9.99V by selecting the 1. GAIN item. 2) Set a limit value of the control output. Select 2. LIMIT item to set a limit value of the control output. In general, it is set as 5.00V. 3) Set a DEAD ZONE. Select 3. DEAD ZONE item to set a no-operation section. Because output voltages are not generated from the established deviation section, it can control the strip safely and efficiently. 30 PORA ELECTRIC MACHINERY CO.,LTD.

31 8. Setting of the Analog Output ( 8. ANALOG OUTPUT ) When pressing the [ENTER Button] in 8. ANALOG OUTPUT, a screen is indicated as below. --ANALOG OUTPUT-- 1.DEVIATION (5V) mm 2.DEV. POLARITY 0 3.CYLINDER (5V) mm 4.CYL. POLARITY 0 5.SHIFT (5V)) mm 6.SHIFT POLARITY 0 1) Set the analog output value due to the strip deviation. Select 1. DEVIATION (5V) item to set the deviation. The strip deviation is outputted as a voltage value. If an input deviation value is the maximum value and the maximum deviation, then 5V is outputted. (When setting as 100mm, 5V is outputted if the strip deviation becomes 100mm.) 2) It changes normal/reverse of analog output values on the strip deviation. Select 2. DEV. POLARITY item to change output values on 1. DEVIATION (5V) into normal/reverse. (When it sets as reverse and 100mm, -5V is outputted if the strip deviation becomes 100mm.) 3) It sets analog output values according to the cylinder position. Select 3. CYLINDER (5V) item to output the cylinder position as a voltage value. If the entered cylinder position is the maximum value and the maximum deviation, then 5V is outputted. (When setting as 100mm, 5V is outputted if the cylinder position becomes 100mm.) 4) It changes normal/reverse of analog output values on the cylinder position. Select 4. CYL. POLARITY item to change output values on 3. CYLINDER (5V) into normal/reverse. (When it sets as reverse and 100mm, -5V is outputted if the cylinder position becomes 100mm.) 5) It sets analog out values according to the shift value. Select 5. SHIFT (5V) item to output the shift value (control shift value + analog shift value) as a voltage value. If the entered deviation value is the maximum, then 5V is outputted. 6) It changes normal/reverse of analog output values according to the shift value. Select 6. SHIFT POLARITY item to change output values on 5. SHIFT (5V) into normal/reverse. (When it sets as reverse and 100mm, -5V is outputted if the shift value becomes 100mm.) PORA ELECTRIC MACHINERY CO.,LTD. 31

32 Digital Strip Position Amplifier 9. Other Setting ( 9. ETC ) When pressing the [ENTER Button] in the 9. ETC, a screen is indicated as below. --ETC-- 1.SHIFT STEP 0.0mm 2.SHIFT CONTROL POL. 0 3.SHIFT INPUT MODE BOTH 4.SHIFT LIMIT 10.0mm 5.DITHER ON 6.DITHER FREQUENC 100Hz 7.LARGE DEVIATION 900mm 8.ROLL OUT CH_A 900mm 9.ROLL OUT CH_B 900mm 1) It sets a moving distance for the SHIFT button. Select the 1. SHIFT STEP item to set the moving distance when pressing the [9. SHIFT (UP, DOWN) Button] once within a range of 0~9.9mm. 2) It changes normal/reverse of the SHIFT button. Select the 2. SHIFT CONTROL POL. item to change normal/reverse of the shift direction. 3) It sets an input mode of the SHIFT. Select the 3. SHIFT INPUT MODE item to set an input mode of the shift. SINGLE = Operates only as a digital shift. BOTH = Operates by adding digital and analog shifts. 4) It sets a limit value of the SHIFT. Select the 4 SHIFT LIMIT item to set a limit value of the shift. 5) Setting of the dither function Turns the 5. DITHER function ON/OFF. 6) Setting of the dither function s frequency Select the 6. DITHER FREQUENC item to set an oscillating frequency of the dither function 50Hz = It generates vibrations of 50 times per second. 100Hz = It generates vibrations of 100 times per second. 7) Setting of the alarm to warn the excessive strip deviation Select the 7. LARGE DEVIATION item to set a range to indicate the alarm of excessive strip deviation. 8) Setting of a range to indicate the alarm for strip deviations of the A side s sensor Select 8. ROLL OUT CH_A item to set a range to indicate the alarm for strip deviations of the A side s sensor. 9) Setting of a range to indicate the alarm for strip deviations of the B side s sensor Select 9. ROLL OUT CH_B item to set a range to indicate the alarm for strip deviations of the B side s sensor. 32 PORA ELECTRIC MACHINERY CO.,LTD.

33 10. Setting of the Line Speed ( 1. LINE SPEED ) When pressing the [ENTER Button] in 1. LINE SPEED after moving to the [NEXT], a screen is indicated as follows. It is used when required to control the GAIN value automatically depending on the line speed. --LINE SPEED-- 1.LINE SPEED ZERO 0000mpm 2.LINE SPEED SPAN 1000mpm 3.ZERO (V) 00V 4.SPAN (V) 10V 5.I HOLD SPEED 0000mpm 6.BREAK POINT X 1000mpm 7.BREAK POINT Y 50% 8.B.P POLARITY 0 1) Set the minimum line speed. Select the 1. LINE SPEED ZERO item to set the minimum line speed. 2) Set the maximum line speed. Select the 2. LINE SPEED SPAN item to set the maximum line speed. 3) Set external voltages entered from the minimum line speed. Select the 3. ZERO (V) item to set external voltages entered from the minimum line speed. 4) Set external voltages entered from the maximum line speed. Select the 4. SPAN (V) item to set external voltages entered from the maximum line speed. 5) Set a line speed (Used in the PI control.) It is used in the PI control mode, and select the 5. I HOLD SPEED item to set a line speed for initial moving. 6) Set a line speed for initial moving. Select the 6. BREAK POINT X item to set a line speed for initial moving when controlling it according to the line speed. 7) Set a gain value for initial moving. Select the 7. BRAKE POINT Y item to set a gain value for initial moving when controlling it according to the line speed. 8) Set normal/reverse of the break point Select the 8. B.P POLARITY item to change the break point. PORA ELECTRIC MACHINERY CO.,LTD. 33

34 Digital Strip Position Amplifier 11. Setting of the Analog Shift ( 2. ANALOG SHIFT ) When pressing the [ENTER Button] in the 2. ANALOG SHIFT, a screen is indicated as below. --ANALOG SHIFT-- 1.SHIFT LENGTH 010.0mm 2.ZERO READ(BCD) SPAN READ(BCD) CENTER READ(BCD) ANALOG LIMIT 050.0mm 6.CONTROL POL 0 7.ANA. CENTERING 0 1. SHIFT LENGTH Set the maximum shift distance. 2. ZERO READ (BCD) Set the minimum value for the analog shift. After decreasing the analog shift volume to the minimum, the minimum value is set when pressing the [ENTER Button]. 3. SPAN READ (BCD) Set the maximum value for the analog shift. After increasing the analog shift volume to the maximum, the maximum value is set when pressing the [ENTER Button]. 4. CENTER READ (BCD) Set the intermediate value for the analog shift. After turning the analog shift volume to make the A/D value around intermediate on the bottom of display, the intermediate value is set when pressing the [ENTER Button]. 5. ANALOG LIMIT Set a distance to limit moving of the analog shift. 6. CONTROL POL Change a moving direction of the analog shift into normal/reverse. 7. ANA. CENTERING 0 = Setting of the cylinder s central position according to the setting of CENTER READ. 1 = Setting of the cylinder s central position based on the ZERO and SPAN values. (It is not required to set the 4. CENTER READ (BCD).) 34 PORA ELECTRIC MACHINERY CO.,LTD.

35 12. Setting of the Nonlinear ( 3. NONLINEAR ) When pressing the [ENTER Button] in the 3. NONLINEAR, a screen is indicated as below. --NONLINEAR-- 1. DEV. POINT X1 25% 2. OUT. POINT Y1 25% 3. DEV. POINT X2 50% 4. OUT. POINT Y2 50% 5. DEV. POINT X3 75% 6. OUT. POINT Y3 75% 1) Set a deviation distance. 1. DEV. POINT X1 Set a deviation position of X1. 3. DEV. POINT X2 Set a deviation position of X2. 5. DEV. POINT X3 Set a deviation position of X3. 2) Set a control output. 2. OUT. POINT Y1 Set a deviation position of Y1. 4. OUT. POINT Y2 Set a deviation position of Y2. 6. OUT. POINT Y3 Set a deviation position of Y3. If arbitrary setting values are not worked normally, set them as the following values. X1=25%, X2=50%, X3=75% Y1=25%, Y2=50%, Y3=75% PORA ELECTRIC MACHINERY CO.,LTD. 35

36 Digital Strip Position Amplifier 13. User Setting Screen ( 4. USER EN/DI & ALARM SET ) When pressing the [ENTER Button] in the 4. USER EN/DI & ALARM SET after moving to the [NEXT], a screen is indicated as below. --USER EN/DI & ALARM SET-- 1. SHIFT SELECT OFF 2. SHIFT MEMORY OFF 3. LINE SPEED OFF 4. NOLINEAR OFF 5. NO PLATE INPUT UN-USE 6. LAMP1 FAIL INPUT UN-USE 7. LAMP2 FAIL INPUT UN-USE 8. ROLL OUT INPUT UN-USE 1) Setting of the shift control Select the 1. SHIFT SELECT item to choose a shift control method. DIG+ANA = It uses both digital and analog shift values. ANALOG = It uses only analog shift. DIGITAL = It uses only digital shift. DISABLE = It does not use shift. 2) Setting to use the shift memory Select the 2. SHIFT MEMORY item to use or clear the shift memory function. 3) Setting to use the function to interwork the line speed Select the 3. LINE SPEED item to use or clear the function to control the line speed. 4) Setting to use the nonlinear Select the 4. NONLINEAR item to use or clear the nonlinear function. 5) Setting to use the alarm of no strip Select the 5. NO PLATE INPUT item to set whether or not to operate the alarm signal terminal and lamp of no-strip. 6) Setting to use the lamp1 alarm Select the 6. LAMP1 FAIL INPUT item to set whether or not to operate the lamp1. 7) Setting to use the lamp2 alarm Select the 7. LAMP2 FAIL INPUT item to set whether or not to operate the lamp2. 8) Setting to use the alarm of strip deviation Select the 8. ROLL OUT INPUT item to set whether or not to operate the alarm signal terminal and lamp of strip deviation. 36 PORA ELECTRIC MACHINERY CO.,LTD.

37 14. Setting of the Display ( 5. DISP POLARITY ) When pressing the [ENTER Button] in the 5. DISP POLARITY, a screen is indicated as below. --DISP POLARITY-- 1. OUTPUT 0 2. STRIP DEVIATION 0 3. CYLINDER 0 4. STAGGER 0 5. SHIFT 0 1) Setting to indicate output voltages Signs (+/-) of output voltages can be changed reversely to be indicated on the display by selecting 1. OUTPUT item. 2) Setting to indicate the strip deviation values Signs (+/-) of the strip deviation values can be changed reversely to be indicated on the display by selecting 2. STRIP DEVIATION item. 3) Setting to indicate the cylinder position values Signs (+/-) of the cylinder position values can be changed reversely to be indicated on the display by selecting 3. CYLINDER item. 4) Setting to indicate the stagger control voltage values Signs (+/-) of the stagger control voltage values can be changed reversely to be indicated on the display by selecting 4. STAGGER item. 5) Setting to indicate the shift value Signs (+/-) of the shift value can be changed reversely to be indicated on the display by selecting 5. SHIFT item. PORA ELECTRIC MACHINERY CO.,LTD. 37

38 Digital Strip Position Amplifier Other Functions & Setting 1. Test Mode When pressing the [AUTO Button] in the AUTO mode for 5 seconds, it enters into the test mode. Without entering into the setting menu even in operation, the following setting items can be changed. <TEST MODE> CPC STAGGER OFF A-SFT +00.0mm OUT +0.00V D-SFT +00.0mm DEV mm SPEED 0000.mpm CYL mm STG mm SIGMA +00.0mm PLS 000 R I/P/PI P STG A P GAIN 100% STG A I TIME 00.0s STG L 000mm OUTGAIN 1.00V PULSE 0000P/R [EXIT] Buttons to be handled when setting the test mode Enter into the test mode by using keys below to move items or to change the setting values. HEALTHY ALARM Button to enter into the test mode / confirm Pressing for 3 seconds Entering into the test mode Pressing once Confirm button REMOTE LOCAL AUTO MANU CENTER ESC CLEAR ENTER Buttons to move items/ change setting values LEFT RIGHT SHIFT button + - UP DOWN SHIFT How to Change the Setting Values - When pressing the [Button to enter into the test mode / confirm] for 3 seconds, it enters into the test mode. - Press the [Buttons to move items / change setting values] to move to the desired item. - When pressing the [Button to enter into the test mode / confirm] once, it becomes the state enabling to change the setting values. - Press the [Buttons to move items / change setting values] to change into the desired setting value, and press the [Button to enter into the test mode / confirm] once to return. - After the setting is completed, press the [Buttons to move items / change setting values] to move to the EXIT item, and press the [Button to enter into the test mode / confirm] to exit the test mode. 38 PORA ELECTRIC MACHINERY CO.,LTD.

39 1 Selection of Control Mode 2 Setting of P GAIN Value 3 Setting of I TIME Value 4 Setting of Control Output GAIN Value <TEST MODE> CPC STAGGER OFF A-SFT +00.0mm OUT +0.00V D-SFT +00.0mm DEV mm SPEED 0000.mpm CYL mm STG mm SIGMA +00.0mm PLS 000 R I/P/PI P STG A P GAIN 100% STG A I TIME 00.0s STG L 000mm OUTGAIN 1.00V PULSE 0000P/R [EXIT] 5 Setting of Stagger A1 Signal 6 Setting of Stagger A2 Signal 7 Setting of Stagger Level 8 Setting of Stagger Pulse 9 Exit of Test Mode 1) Setting of the Control Mode ( Refer to page 29 for how to set the control mode) [1 Selection of Control Mode] I/P/PI It selects the control mode. [2 Setting of P GAIN Value] P GAIN It sets the P GAIN value. (Use for the P or PI control mode.) [3 Setting of I TIME Value] I TIME It sets the maximum operating speed. (Use for the PI control mode.) 2) Setting of Control Output Value ( Refer to page 30 for how to set the control output value) [4 Setting of Control Output GAIN Value] OUTGAIN It can select the 1. GAIN item to set the voltage value per 1mm of strip deviation up to 9.99V. 3) Setting of Stagger ( Refer to page 25 for how to set the stagger.) [5 Setting of Stagger A1 Signal] STG A1 It sets a time to reach the highest point of a signal. [7 Setting of Stagger Level] STG L It adjusts a stagger signal s height. [6 Setting of Stagger A2 Signal] STG A2 It sets a time to keep the highest point of a signal. [8 Setting of Stagger Pulse] PULSE It sets the number of pulses for moving a stagger by a step. 4) Exit of the Test Mode [9 Exit of Test Mode] EXIT If the setting is completed, it exits the test mode. PORA ELECTRIC MACHINERY CO.,LTD. 39

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 OWNER S MANUAL PW MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 ANY CHANGES OR MODIFICATIONS IN CONSTRUCTION OF THIS UNIT DEVICE WHICH IS NOT APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIACE COULD VOID

More information

K3NX Process Meter OPERATION MANUAL

K3NX Process Meter OPERATION MANUAL Cat.No. N90 E1 1 K3NX Process Meter OPERATION MANUAL K3NX Process Meter Operation Manual Produced January 1998 Notice: OMRON products are manufactured for use according to proper procedures by a qualified

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

Revision 1.2d

Revision 1.2d Specifications subject to change without notice 0 of 16 Universal Encoder Checker Universal Encoder Checker...1 Description...2 Components...2 Encoder Checker and Adapter Connections...2 Warning: High

More information

800 Displaying Series Flowmeter

800 Displaying Series Flowmeter TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

1. Safety precautions (Must Read)

1. Safety precautions (Must Read) Table of contents 1. Safety precautions (Must Read)... 2 2. Components... 4 3. Names of parts... 5 4. Dimensional drawing of main unit... 5 5. Installation and precautions... 6 6. Wiring and precautions...

More information

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter Cat. No. N093-E1-1A K3NR Frequency/Rate Meter K3NR Frequency/Rate Meter Operation Manual Revised February 2001 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

Smart-Encoder : Optical Incremental

Smart-Encoder : Optical Incremental 1. Introduction The Smart-Encoder effectively eliminates multiple encoder part numbers by bringing intelligence and security to its design. In seconds, a four-digit LED display with two push-buttons enables

More information

DH551C/DH550C/DL550C Double Sided Display User Manual

DH551C/DH550C/DL550C Double Sided Display User Manual DH551C/DH550C/DL550C Double Sided Display User Manual Disclaimer BenQ Corporation makes no representations or warranties, either expressed or implied, with respect to the contents of this document. BenQ

More information

Digital differential Pressure switch Model DPS Instruction manual

Digital differential Pressure switch Model DPS Instruction manual Digital differential Pressure switch Model DPS Instruction manual DPSeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054 Nova

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

GC61 Digital Pressure Gauge. Operation Manual

GC61 Digital Pressure Gauge. Operation Manual TY-GC61-009A エ GC61 Digital Pressure Gauge Operation Manual 2016. 3 TY-GC61-009A 1/24 For proper and safe operation GC61 Digital Pressure Gauge is a compact digital pressure gauge which complies with the

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

17 19 PROFESSIONAL LCD COLOUR MONITOR ART 17 19 PROFESSIONAL LCD COLOUR MONITOR ART. 41657-41659 Via Don Arrigoni, 5 24020 Rovetta S. Lorenzo (Bergamo) http://www.comelit.eu e-mail:export.department@comelit.it WARNING: TO REDUCE THE RISK OF FIRE

More information

GC30 Digital Differential Pressure Gauge Operation Manual

GC30 Digital Differential Pressure Gauge Operation Manual TY-GC30-001A GC30 Digital Differential Pressure Gauge Operation Manual NAGANO KEIKI CO., LTD 2004.02.12 For safety of use TY-GC30-001A In order to safely and correctly utilize this device, please read

More information

ADJUSTABLE SPEED DRIVES. nc1 Drive

ADJUSTABLE SPEED DRIVES. nc1 Drive ADJUSTABLE SPEED DRIVES nc1 Drive Ultra-Compact Sub-Micro Drive The nc1 is a sub-micro, or nano-sized drive with a full range of features to meet the needs of nearly any user. The nc1 is designed to be

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

C200H-AD002/DA002 Analog I/O Units Operation Guide

C200H-AD002/DA002 Analog I/O Units Operation Guide C200H-AD002/DA002 Analog I/O Units Operation Guide Revised September 1995 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes

More information

16-CH Color Full Duplex Multiplexer Instruction Manual

16-CH Color Full Duplex Multiplexer Instruction Manual 16-CH Color Full Duplex Multiplexer Instruction Manual 707-V1.5(S) Index: 1. Safety Warning 3 2. Introduction 3 3. Features 4 4. Specification 5 5. Front Panel Keypad 6 6. Back Panel Connection 10 7. Menu

More information

COLOR TFT LCD MONITOR WITH MULTI-TOUCH FUNCTION Manual

COLOR TFT LCD MONITOR WITH MULTI-TOUCH FUNCTION Manual COLOR TFT LCD MONITOR WITH MULTI-TOUCH FUNCTION Manual DEAR CUSTOMERS Thank you for choosing our TFT LCD (liquid crystal display) monitor. This product employs integrate circuits, low power consumption,

More information

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment) OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for

More information

COLOR TFT LCD MONITOR. User Manual

COLOR TFT LCD MONITOR. User Manual COLOR TFT LCD MONITOR User Manual 0 GENERAL INFORMATION Thank you for choosing our TFT LCD (liquid crystal display) monitor. This product employs integrate circuits, low power consumption, and no radiation

More information

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR 28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. TABLE OF CONTENTS 1, General information...

More information

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated) INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

VITEK VTM-TLM191 VTM-TLM240

VITEK VTM-TLM191 VTM-TLM240 VTM-TLM191 VTM-TLM240 19 & 24 Professional LED Monitors with HDMI, VGA, and Looping BNC VITEK FEATURES 19 & 24 Wide Screen LED Display Panel HDMI, VGA, and Looping BNC Composite Video Inputs & Stereo Audio

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

INST No.CP CP Computing unit. Instruction Manual. Important Notice. Keep this manual with due care after understanding operation.

INST No.CP CP Computing unit. Instruction Manual. Important Notice. Keep this manual with due care after understanding operation. INST No.CP970-2 CP Computing unit Model CP970 Instruction Manual Important Notice Keep this manual with due care after understanding operation. 新栄熱計装株式会社 - Contents - Preface... 1 1 Outline... 2 2 Specifications...

More information

M-CT6 Camera-Top Monitor

M-CT6 Camera-Top Monitor M-CT6 Camera-Top Monitor Owner s Manual 1 Thank you for purchasing a Marshall M-CT6 camera-top monitor. The M-CT6 is a great tool for focusing, composing, and viewing images/video clips directly from your

More information

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference. 4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. CONTENTS 1. GENERAL INFORMATION...3 2. 3. 1.1. 1.2. 1.3. 2.1.

More information

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL Installation and programming Manual v2.2 1 MARSS Solar Defender SYSTEM This guidebook provides the essential instructions to install and configure the

More information

Label Applicator HERMA 400

Label Applicator HERMA 400 Label Applicator HERMA 400 Info GB V6.0 / 30.3.07 [ Facts & Data ] R Constructional variant Right-hand or left-hand version, always flexible to use L Power supply / Line voltage Max. power consumption

More information

EZ Encoder : Optical Incremental (P Series)

EZ Encoder : Optical Incremental (P Series) 1. Introduction Our EZ Encoders effectively eliminate multiple encoder part numbers by bringing intelligence and security to the design. A four-digit LED display with two push-buttons enables the user

More information

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope Quick Start RSHS1000 Series Handheld Digital Oscilloscope General Safety Summary Carefully read the following safety precautions to avoid personal injury and prevent damage to the instrument or any products

More information

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Model DT-311J And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL 1. GENERAL The DT-311J DIGITAL

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Installation and Maintenance Instructions for GC51 Rangeable Pressure Transmitter

Installation and Maintenance Instructions for GC51 Rangeable Pressure Transmitter Installation and Maintenance Instructions for GC51 Rangeable Pressure Transmitter LOOK FOR THIS AGENCY MARK ON OUR PRODUCTS Version 6.03 5/11 2011 Ashcroft Inc. 250 East Main Street, Stratford, CT 06614

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Operating Instructions

Operating Instructions Operating Instructions LCDRV700 Digital LCD Color Monitor Please read this manual thoroughly before operating the unit, and keep it for future reference. V1.0 Contents 1. Precautions 2. Features 1 3 3.

More information

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor Touch Display LCD Monitor User Manual Installation Guide 15 Resistive Touch LCD Monitor MODEL: KK1500-TR i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com User

More information

Single Axis Position Controller

Single Axis Position Controller SERIES P9511 Single Axis Position Controller Compact Construction Simple Go-to operation Integrated Relay Output Integrated Mains Power Supply ELEKTRO-TRADING sp. Z o.o. 44-109 Gliwice, ul. Mechaników

More information

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance: AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

Good Display Specifications

Good Display Specifications Specifications Type: Model No. Description: 5.0inch TFT LCD module GD567M03-GTI050TN22 5.0 LCD with 640 x RGB x 480 dots Supports CVBS/Video & VGA input RoHS Compliant Prepared: Xiaoli Lan Checked: Moon

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display Sens Mini-Cube Sens with Easy-to-Read LED Display Industry s smallest, lightest l Both analog bar and digital pressure values are displayed Two independent outputs plus one analog output are available

More information

PSM-003. Micro Polarization Controller/Scrambler. User Guide

PSM-003. Micro Polarization Controller/Scrambler. User Guide PSM-003 Micro Polarization Controller/Scrambler User Guide Version: 1.0 Date: August 23, 2012 General Photonics, Incorporated is located in Chino California. For more information visit the company's website

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

FRQM-2 Frequency Counter & RF Multimeter

FRQM-2 Frequency Counter & RF Multimeter FRQM-2 Frequency Counter & RF Multimeter Usage Instructions Firmware v2.09 Copyright 2007-2011 by ASPiSYS Ltd. Distributed by: ASPiSYS Ltd. P.O.Box 14386, Athens 11510 (http://www.aspisys.com) Tel. (+30)

More information

COLOR TFT LCD MONITOR. Manual

COLOR TFT LCD MONITOR. Manual COLOR TFT LCD MONITOR Manual Safety defended: Properly maintains your system to be possible to guarantee its service life and to reduce the damage risk. It should avoid the damp and exceeding temperature

More information

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD Our component video switcher allows four different component video and stereo/digital audio sources to share two video displays. Manage multiple

More information

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade) USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade) This Manual is revisable without further notice Contents CONTENTS ------------------------------------------------------------------- 1

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing. Product Data Electrical Data SST (Transmitter) SSR (Receiver) Supply voltage 18 30 V dc Max. Voltage ripple 15 % (within supply range) Current consumption 100 ma (RMS) 75 ma Digital - 100 ma Max. outputs

More information

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES Programmable DC Source Sink and Source Capability Conventional DC sources usually have the function of power supply (source) only without power absorption (sink) function. In addition to the source function,

More information

48x24. Options ORDER NUMBER OF TYPE PFL B

48x24. Options ORDER NUMBER OF TYPE PFL B Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Contactless encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED LED indicates measuring range Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024,

More information

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.

More information

Digital differential pressure controller Model DPD Instruction manual

Digital differential pressure controller Model DPD Instruction manual Digital differential pressure controller Model DPD Instruction manual DPDeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054

More information

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions TABLE OF CONTENTS Important Safety Instructions...1 1.1 Safety precautions and maintenance....1 1.2 Use.......4 1.3 Installation Notes.......7 Package Content...9 2.1 Unpacking...9 2.2 Accessories......10

More information

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216 Light Program Controller VLC-3 USER'S MANUAL +50,1 +50,1 1 : $ ' 2 7. 6 8 ' 5, 7 6 6. $ ( 3 352*5$0 0,16(& )81&7,216 6(77,1*6 & 8 5 5 ( 1 7 3 ( 5, 2 ' M 890-00189 rev. 04 K 895-00406 rev. 00 GENERAL...

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0 AN2 Series 900tvl CMOS Technology High Resolution Sensor P/N 01.BSM.16.2000030 V1.0 Product Made in China under ISO9001 & ISO1400 standards Manual Printed in China v1.0 elinetechnology.com CAUTION RISK

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure

More information

USER S MANUAL. FX2N-8AD Analog input block

USER S MANUAL. FX2N-8AD Analog input block USER S MANUAL FX2N-8AD Analog input block FX2N-8AD Analog input block Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar

More information

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS KingWash 7QX 7x40w,Zoom 5-60degree User manual Please read the instructions carefully before use TABLE OF CONTENTS 1. Safety Instructions... 2 2. Technical Specifications... 4 3. How To Control The Unit...

More information

Digital Indicating ORP Meter AER-101-ORP. Instruction Manual

Digital Indicating ORP Meter AER-101-ORP. Instruction Manual Digital Indicating ORP Meter AER-101-ORP Instruction Manual Preface Thank you for purchasing our AER-101-ORP, Digital Indicating ORP Meter. This manual contains instructions for the mounting, functions,

More information

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5. EF User Guide UD51 Second encoder small option module for Unidrive Part Number: 0460-0084-05 Issue Number: 5 www.controltechniques.com Safety Information The option card and its associated drive are intended

More information

EVENT INPUT/OUTPUT MODULE [PUME]

EVENT INPUT/OUTPUT MODULE [PUME] PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm

More information

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display. ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read

More information

OPERATION MANUAL. USF-402AADC Audio Analog Digital Converter. 1 st Edition

OPERATION MANUAL. USF-402AADC Audio Analog Digital Converter. 1 st Edition OPERATION MANUAL USF-402AADC Audio Analog Digital Converter 1 st Edition Precautions Important Safety Warnings [Operation] Hazard [Transportation] Hazard [Circuitry Access] Do not operate the unit under

More information

User Manual Color video door phone

User Manual Color video door phone User Manual Color video door phone CDV-70AR3 Thank you for purchasing COMMAX products. Please carefully read this User s Guide (in particular, precautions for safety) before using a product and follow

More information

DCP100 Digital Control Programmer Specifications

DCP100 Digital Control Programmer Specifications DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

Marine LCD Display MV-1504/1704/1904/2104

Marine LCD Display MV-1504/1704/1904/2104 Marine LCD Display MV-1504/1704/1904/2104 Operating Manual (04-0-13122013) St. Petersburg 2013 v.0.0 Table of Contents 1. GENERAL INFORMATION...4 2. DELIVERY SET...4 3. SPECIFICATIONS...5 4. MOUNTING AND

More information

Electronic Pulse Counter Combination device

Electronic Pulse Counter Combination device Electronic Pulse Counter Combination device measuring monitoring analysing Input: pulse counter, time meter Display: 6-digit LED Height of digits: 14/8 mm Operation with front-panel buttons Material: plastic

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

Indoor/Outdoor Security System with Quad Monitor User s Manual

Indoor/Outdoor Security System with Quad Monitor User s Manual Indoor/Outdoor Security System with Quad Monitor User s Manual 4919539 Important! Please read this booklet carefully before installing or using these units. WARNING - These units should ONLY be opened

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL F90 Series (Rate Indicators / Controllers) INSTRUCTI MANUAL FEATURES DIN 48 9mm DIN 48 9mm Standard Panel Size Monitor & Preset Type 1 Monitor type with the large display 2 Preset Type can make the upper/lower

More information