1 Bruce Quimby Application Scientist Agilent Technologies October 28, 2009 Page 1

2 Tools For Improving GC/MS Analysis Retention Time Locking (RTL) Method Translation Synchronous SIM/Scan Column effluent split to an NPD Column backflushing Deconvolution Reporting Software (DRS) Page 2

3 Retention Time Locking Get precisely the same retention times: After cutting or replacing column On all instruments in a lab and other labs (method sharing) Greatly reduces method maintenance for updating: peak recognition (RT) windows SIM group start times integration events Reduces data review time Makes management of large screening databases much easier Simple procedure restores all RTs to original calibrated values Process moves RTs back to calibrated values, does not change calibrated value to current (different) RT Look for new targets in archived data, since RTs always the same Page 3

4 How Does RTL Work? For each method: A set of five runs of retention time vs inlet pressure for a single locking compound is collected (only once per method) The calibration is stored with the method When locking a new instrument, the locking compound is run and its RT is measured RTL software calculates new inlet pressure that makes the RT of the locking compound and all analytes precisely match that of the original method U pdating RTs of individual cal compounds and timed events unnecessary If a table of hundreds of RTs is collected under RTL conditions, anyone anywhere can lock to the same conditions and get the same RTs. This is basis of Agilent screening databases for Forensic Tox compounds, pesticides, etc. Page 4

5 RTL Example RTL keeps the retention times of all analytes typically within min absolute. Locking is a simple procedure using 1 compound. After pressure adjustment, all compounds fall within their RT recognition window min. Initial run 4.72 psi Original locked method min min. Trim 1 meter 4.72 psi Relock 4.42 psi Column trimmed, locking compound run at original pressure (RT is too short) RTL calculates new inlet pressure to restore RTs Page 5

6 Agilent s Method Translation Software A technique invented by Agilent that calculates the inlet pressure and oven temperature program for changing: Analysis speed (example: 4 x faster) Column dimensions (with same phase ratio) Carrier gas type (example: Changing from He to H 2 ) Column outlet pressure (MSD vs NPD vs CFT Splitter) Determines the required conditions with a calculator instead of trial and error GC runs in the laboratory Key benefits: Relative elution order is maintained. Retention times with new method are accurately predicted Substantial saving in method development time, especially for screening methods with large numbers of analytes. Page 6

7 Speed Scaling Constant Pressure RTL Methods Allows method to be adjusted to optimal speed on a specific system. Use MTL software to calculate changes in pressure and temperature ramps corresponding to desired speed gain Generate new RTL calibration for the new method Peaks will elute in same relative order as before Lock system using target t compound to: (original target time) (speed gain) Now all retention ti times in new method will be equal to: original RT speed gain Page 7

8 1-5 ng Test Mix: DB-5MS, 1x MSD Direct 10C/min and 1.8 ml/min initial flow 1 Amphetamine 15 Lorazepam 2 Phentermine 16 Diazepam 3 Methamphetamine 17 Hydrocodone 4 Nicotine 18 Tetrahydrocannabinol 5 Methylenedioxyamphetamine(MDA) 19 Oxycodone 6 Methylenedioxymethamphetamine(MDMA) 20 Temazepam 7 Methylenedioxyethylamphetamine 21 Flunitrazepam 8 Meperidine 22 Diacetylmorphine 9 Phencyclidine 23 Nitrazepam Methadone 24 Clonazepam 11 Cocaine 9 25 Alprazolam 12 SKF-525a (RTL Compound) 26 Lysergide (LSD) 13 Oxazepam Strychnine Codeine Trazodone TIC: 25mix_340C_2.D\data.ms Page 8

9 DB-5MS: Comparison of Different Speeds on MSD 4X method RTs are precisely the same as 1X divided by 4 1 x 30 m, 10C/min and 1.7 ml/min: 120V oven and Standard Turbo 2x m, 20C/min and 1.2 ml/min: 120V oven and Standard Turbo 3 x m, 30C/min and 2.7 ml/min: 240V oven and Perf Turbo 4 x m, 40C/min and 5.9 ml/min: 240V oven and Perf Turbo Page 9

10 Why Use Agilent s Synchronous SIM/Scan? Get SIM and Scan Data in a single run which saves time - SIM = maximum sensitivity for target compounds - Scan = best confirmation of targets and identification of unknowns - For most methods, changing to SIM/Scan results in little, if any, degadation in signal-to-noise noise compared to SIM only or Scan only modes Page 10

11 How Does Synchronous SIM/Scan Work? Chromatographic Peak SIM data points Scan data points SIM and Scan data points are alternately collected At end of run, two separate data signals are constructed SIM Scan SIM Scan SIM Scan SIM Scan Scan time SIM Scan Each signal can be processed like SIM or Scan collected separately Page 11

12 Why Collect NPD and MSD Simultaneously? NPD gives sensitive nitrogen selective detection: - Identity confirmation (if it is a nitrogen drug, it should respond on NPD) - Faster data review, alternate to MSD for quantitation - Highlights nitrogen drugs that are not in target list - Splitter used also allows backflushing and changing columns without venting MSD Page 12

13 Example of Synchronous SIM/Scan/NPD Fentanyl Ion 245 Scan S/N pk-pk = 8 Ion 146 Scan Ion 189 Scan Ion 245 SIM S/N pk-pk = 77 Ion 146 SIM Ion 189 SIM S/N NPD pk-pk 42 Real whole blood tox sample: Screen for 278 drugs in Scan mode. Screen for low level targets in SIM mode Fentanyl found by SIM at trace level because of 10 fold better S/N NPD trace shows nitrogen peak at same RT as fentanyl in MS data Page 13

14 How Does the Splitter Work? Liquid Injector XEPC Vent NPD New splitter technology Column 7890A GC 5975C MSD Column effluent split between MSD and NPD Reliable, inert, easy to use two way splitter with solvent venting Auxillary EPC control allows no vent column changing and post run backflushing Page 14

15 Why Use Agilent s Column Backflushing? Backflushing removes heavy material from column after elution time of last analyte: - Prevents heavy matrix compounds from eluting in later runs - Reduces column trimming and detector maintenance - Significantly reduces postrun bakeout times (example: 2 min backflush vs 10 min bakeout) Whole blood tox sample TIC Heavies past end of acquisition Page 15

16 How Does Backflushing Work? Split Vent Trap S/S Inlet 25 psi During GC Run Aux EPC 4 psi Flow Splitter or QuickSwap Column MSD Auxillary EPC provides constant pressure makeup gas to post column device. During run, makeup flow is low (~ 1 ml/min) Split Vent Trap S/S Inlet 1 psi After GC Run Aux EPC is programmed Flow Column Aux EPC 45 psi Splitter or QuickSwap MSD to high pressure and inlet to low pressure. Reversed flow quickly sweeps heavies out to split vent trap Page 16

17 Why Use Deconvolution Reporting Software? Deconvolution of mass spectra removes/reduces interferences from chromatographically overlapped peaks: Better identification and confirmation of analytes in high matrix samples Reduces data review time, especially for large screening methods Reduces false positives and false negatives in dirty samples Identification based on matching entire spectrum cleaned of interferences against library. Much more reliable than target/qualifier ratio method. Page 17

18 How Does Deconvolution Work? Ions with the same abundance vs time profile are grouped together to create spectra cleaned of interferences from overlapped peaks Three Overlapped Chromatographic Peaks TIC Interference 1 Interference 2 Target Time Deconvolution Interference 1 m/z Interference 2 Time Time Time Target m/z Page 18

19 AMDIS Looks at Apex Retention Time and Peak Shape Ions whose EICs have the: 1. same apex RT 2. same shape are grouped to form cleaned (extracted) spectra Extracted Ion Chromatograms (EIC) 160 wrong shape 50 These have same 170 shape and same apex RT wrong rt 75 wrong rt 310 wrong rt Page 19

20 Ions With Same RT and Shape Are Grouped and Called Components (Spectra) 50 Extracted spectrum cleaned of interferences 17 0 This spectrum is compared to msl for target hits. Component Peak heights of Extracted Ion EICs give Chromatograms relative (EIC) abundance values for 50 spectra Page 20

21 Example:Spectral Confirmation of Carisoprodol in Blood Extract With High Level of Fatty Acids Abundance Average of to min.: 120C_1MIN_GB20_VIAL2.D\DATA.MS 54.9 Apex spectrum #1 NIST Hit is Oleic acid. Carisoprodol is not in top 100 hits Deconvoluted Spectrum Carisoprodol is #1 Hit in NIST05a m/z--> Spectrum at Carisoprodol RT, not deconvoluted Deconvoluted Spectrum at Carisoprodol RT Match = Library Reference Spectrum of Carisoprodol Page 21

22 Steps in DRS Process Software goes through entire GC/MS scan file and extracts all components (spectra). Each component is automatically searched against the target spectral library. If a component has both: a spectral match factor > than user defined minimum a retention time matching the table RT within a user defined limit It is reported as present. Data reviewer inspects the results and confirms compounds present. Those compounds are then quanted and report generated. Page 22

23 Example: Design 725 Compound Fast Tox Screening System Retention Time Locking (RTL)- use Agilent s New G1674AA Forensic Toxicology RTL Library Method Translation Run 4x faster version (40C/min) of method Synchronous SIM/Scan and Split to NPD Collect 3 signals Scan,SIM, SIM and NPD in one short run Column backflushing Saves bakeout time, gives cleaner baselines, less maintenance Deconvolution Reporting Software (DRS) Biggest time saver. Data reviewed in ~10 min instead of ~1 hour/sample Page 23

24 Fast Tox Screening System Post column device provides: A) 1.4:1 MSD:NPD effluent split B) Solvent venting C) Backflushing Liquid D) No vent column changing Injector XEPC 3.8 psig Solvent Vent NPD S/S Inlet 14.9 psig (nom) 7890A GC Column 10mX025mmidX025umDB5ms 0.25 mm X 0.25 DB-5ms 5975C MSD Page 24

25 Method Parameters for DB-5ms, 4X, NPD/MSD Split on 7890 Ramp 'C/min 'C Hold min MSD Agilent 5975C Initial Solvent Delay 0.5 min Ramp Acquisition Mode SIM/Scan Runtime 7.13 min Scan Range 40 to 570 Postrun 325 'C/min for 0.5 min Threshold 0 Sampling 1 Inlet Split/Splitless p Quad Temp 180 'C Temp 280 'C Source Temp 300 'C Mode Splitless, Constant Pressure Transfer Line 300 'C Pressure (adj to lock) Tune Gain Normalized 1X Purge Flow 50 ml/min Purge time min Splitter 2-way splitter w/ solvent vent Column DB-5ms part # (custom) Pressure 3.8 psig MSD Restictor m x 0.15 mm id 10m x 0.25 mm id x 0.25 um film NPD Restictor m x 0.15 mm id Initial Flow 252mL/min 2.52 Split ratio 1.4:1 MSD:NPD Outlet Splitter Vent time range min Outlet Pressure 3.8 psig Backflush Time 0.5 min Injection volume 1 ul Backflush Temp 325 RT locked to Proadifen at min Backflush Press 76 Page 25

26 SIM Groups Acquired With SIM/Scan SIM Group Peak Name RT min Tgt Q1 Q2 1 Amphetamine Methamphetamine Methylenedioxyamphetamine(MDA) Methylenedioxymethamphetamine(MDMA) Ecgonine Methyl Ester Ethylecgonine Meperidine Ketamine Phencyclidine Tramadol Methadone Dextromethorphan Cocaine Cocaethylene Diazepam Tetrahydrocannabinol Acetyl-Morphine Oxycodone Temazepam Diacetylmorphine Fentanyl Zolpidem Clonazepam-M (amino-) Alprazolam Zaleplon Zopiclone Lysergide (LSD) Page 26

27 Screening A Real Blood Extract Blood extracts are very complex. There are more than 400 detectable peaks in this sample. The problem is to find the compounds of toxicological interest. Fast method: 9.75 min injection to injection (including backflush) Scan TIC SIM TIC NPD Page 27

28 Target Compounds Identified in Sample By DRS 1 Nicotine 2 Nicotinamide 3 Carisoprodol artifact 4 Cotinine 5 Meprobamate 6 Caffeine 7 Carisoprodol 8 Methadone 9 Cyheptamide (ISTD) 10 Oxycodone 11 Cholesterol Scan TIC NPD Page 28

29 Deconvolution of Spectra Eliminates Review Bottleneck For Large Screening Methods Conventional quant approach (~ 1hour / sample review time): Must examine every peak with response at target ion (367 here) Takes ~ 1 hour to review, delete false positives, quant real ones DRS approach (~ 10 min / sample review time) Gives list of compounds present in 1-2 minutes List has many fewer compounds to review. (12 instead of 367) Veryfew false positives and false negatives In the current example, all compounds identifiable by QEDIT or Screener approach were found immediately with deconvolution Can find compounds not identifiable by conventional approach when severe overlap with matrix exists Page 29

30 DRS Report From Scan Data of Sample Page 30

31 Caffeine: Is It There? All 3 qualifiers have problems. It would be good to have more info like a spectral match > 60 to confirm ID, since qualifiers are questionable. Interference Caffeine? TIC Scan Q1 and Q2 have interference overlap Q3 has very low S/N NPD confirms nitrogen at caffeine RT Scan 109 Scan 82 Scan 67 Scan NPD Page 31

32 Caffeine Spectrum Has Interference Problem With Matrix Compound 100 Match = Caffeine Apex Spectrum (no deconvolution) Target Library Reference Spectrum of Caffeine Page 32

33 Caffeine Component Searched Against Target Library Deconvolution improves spectral match quality by removing interfering compound spectrum Match = Component Found at RT of Caffeine Target Library Reference Spectrum of Caffeine Page 33

34 Methadone: Is It There? Scan and NPD Data SIM gives high h S/N 72 Scan confirmation of ratios, but 57 still doubtful 57 Scan 165 Scan NPD confirms N containing peak at Methadone RT NPD Page 34

35 Methadone Spectrum Has Interference Problem With Octadecanoic Acid in Matrix Match = Methadone Apex Spectrum (no deconvolution) Target Library Reference Spectrum of Methadone Page 35

36 Methadone Deconvoluted Spectrum Searched Against Target Library Deconvolution significantly improves spectral match quality by removing interfering octadecanoic acid spectrum Match = 80 Component found at RT of Methadone Target Library Reference Spectrum of Methadone Page 36

37 Alprazolam: Is It There? Deconvolution and conventional quant are both limited by signal-to-noise ratio of scan data. As S/N drops, ions disappear from deconvoluted spectrum 50 Deconvoluted Spectrum Forward Match Reverse 57.5 Second Hit in NIST 05a Page 37

38 Alprazolam at Limit of Detectability in Scan Mode Deconvolution and conventional quant are both limited by signal-to-noise ratio of scan data Both deconvolution and standard quant are at the detection limitit here 279Scan 204 Scan 308 Scan 203 Scan SIM and NPD data aid in confirming very low level of Alprazolam SIM 308 SIM 280 SIM NPD Page 38

39 Time Savings Conventional Method: Scan run: 35 min SIM run: 35 min NPD run: 35 min Data Review: ~1 hour Total: 165 min/sample Fast Tox Method: Scan, SIM, and NPD: 9.75 min Data Review: ~10 min Total: min/sample Page 39

40 Summary Retention Time Locking (RTL)- the same RTs from now on Method Translation speed scale to new column sizes, carrier gases, analysis speeds Synchronous SIM/Scan and Split to NPD Collect 3 signals Scan,SIM, SIM and NPD in one run Column backflushing Saves bakeout time, gives cleaner baselines, less maintenance Deconvolution Reporting Software (DRS) Data review time reduced while quality is improved Page 40

41 Get started quickly Application kit Columns, consumables & checkout mix Application Note and Quick start guide DVD with method parameters 729 compound DRS database for fast screening Video tutorials with step-by-step instructions Pre- configured and pretested for your application On-site application checkout Page 41 Page Feb FY09 Solution Plan Agilent Restricted

42 Thanks For Attending Wow! Did you see that? Page 42

Staying Connected in GC

Staying Connected in GC Staying Connected in GC Daron Decker / Eric Pavlich Chromatography Technical Specialists Page 1 Leaks (Oxygen) Damages GC Columns Repair of the GC column is impossible Replacements means re-calibration

More information

GC/LC-MS: data acquisition rate and peak reconstruction

GC/LC-MS: data acquisition rate and peak reconstruction GC/LC-MS: data acquisition rate and peak reconstruction Nyquist (Shannon-Kotelnikov-Whittaker) theorem Signal sampling does not involve any loss of information as long as the sampling frequency is at least

More information

Achieving More Efficient Data Review with OpenLAB CDS

Achieving More Efficient Data Review with OpenLAB CDS Achieving More Efficient Data Review with OpenLAB CDS Technical Note Introduction Separations have enjoyed major advances that have significantly reduced chromatographic run times. Ultra high performance

More information

Liquid Chromatography- Mass Spectrometer Manual

Liquid Chromatography- Mass Spectrometer Manual Liquid Chromatography- Mass Spectrometer Manual Joshua Willis, Elizabeth Sattely Department of Chemical Engineering Stanford University November 6, 2014 Abstract This manual will explain the LC/MS, its

More information

GCxGC Comprehensive Two-Dimensional Gas Chromatography

GCxGC Comprehensive Two-Dimensional Gas Chromatography GCxGC Comprehensive Two-Dimensional Gas Chromatography Delivering the Right Results LECO s GCxGC Comprehensive Two-Dimensional Gas Chromatography Take your chromatography to the next level LECO comprehensive

More information

GCxGC Comprehensive Two-Dimensional Gas Chromatography

GCxGC Comprehensive Two-Dimensional Gas Chromatography GCxGC Comprehensive Two-Dimensional Gas Chromatography Delivering the Right Results GCxGC Comprehensive Two-Dimensional Gas Chromatography Take your chromatography to the next level LECO comprehensive

More information

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V. 1234 Hach Hall 515-294-5805 www.cif.iastate.edu Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V. Location: Contact: 1238 Hach Hall Steve Veysey, 1234 Hach Hall; Kamel Harrata,

More information

Agilent 7000 Series Triple Quadrupole GC/MS System

Agilent 7000 Series Triple Quadrupole GC/MS System Agilent 7000 Series Triple Quadrupole GC/MS System Concepts Guide The Big Picture Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by

More information

Supporting Information for Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment

Supporting Information for Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment Supporting Information for Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment Davis W. Rempe, * Stephen E. Reichenbach, * Qingping Tao, Chiara Cordero, Wayne E. Rathbun,

More information

Magnum GCMS Training and Operating Instructions 02/07/2012 S.V.

Magnum GCMS Training and Operating Instructions 02/07/2012 S.V. Magnum GCMS Training and Operating Instructions 02/07/2012 S.V. 1234 Hach Hall 515-294-4805 www.cif.iastate.edu Location: Contact: 1238 Hach Hall Steve Veysey, 1234 Hach Hall; Kamel Harrata, 1236 Hach

More information

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist Agilent Site Preparation InfinityLab Checklist LC Series Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification

More information

HPLC Tips and Tricks. Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI)

HPLC Tips and Tricks. Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI) HPLC Tips and Tricks Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI) The world leader in serving science Overview Thermo Scientific UltiMate 3000

More information

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist 1290 Site Preparation Infinity LC/1260 Checklist Infinity LC Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this

More information

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area. BitWise. Instructions for New Features in ToF-AMS DAQ V2.1 Prepared by Joel Kimmel University of Colorado at Boulder & Aerodyne Research Inc. Last Revised 15-Jun-07 BitWise (V2.1 and later) includes features

More information

AIM INTRODUCTION SIMPLIFIED WORKFLOW

AIM INTRODUCTION SIMPLIFIED WORKFLOW CD-R PATENT PROTECTION: BRAND CHARACTERIZATION TO IDENTIFY COUNTERFEIT GOODS USING SIMPLIFIED MASS SPECTROMETRY James Morphet and Eleanor Riches Waters Corporation, Manchester, UK AIM To provide an easy-to-use

More information

How Quadrupole Size Affects Research

How Quadrupole Size Affects Research Quadrupole Size Comparison APPLICATION NOTE NOTE How Quadrupole Size Affects Research Mass Spectrometry is one of the most widely used analytical techniques and the most common mass analyzer is the quadrupole.

More information

Introduction to System Suitability Tests Michael Wright Bioanalytical Services LGC Fordham, UK

Introduction to System Suitability Tests Michael Wright Bioanalytical Services LGC Fordham, UK Introduction to System Suitability Tests Michael Wright Bioanalytical Services LGC Fordham, UK Science for a safer world 13/10/2016 2 2 What is a System Suitability Test (SST)? Also referred to as a System

More information

STANDARD OPERATING PROCEDURE:

STANDARD OPERATING PROCEDURE: Q-EXACTIVE STANDARD OPERATING PROCEDURE: Purpose of this Instrument: Essential tool for molecular weight identification for small molecules, peptides, proteins, ect. Location: WVU Chemistry Research Laboratory

More information

If you have questions or problems in providing anything described as Customer

If you have questions or problems in providing anything described as Customer Agilent Site Preparation 1260 Infinity Checklist Purification Solution Thank you for purchasing Agilent 1260 Infinity Purification Solution. To get you started and to assure a successful and timely installation,

More information

UWPR Advancing Proteomics

UWPR Advancing Proteomics How to setup a PRM assay on the QExactive Plus (SW v 2.7) Inclusion List First you need a list of peptides representing the proteins you want to monitor/quantify. You can use prior DDA data, databases

More information

BR2517B. 168 Diode Array & 166 Programmable Detector Modules. Packaging Processing. Bid on Equipment

BR2517B. 168 Diode Array & 166 Programmable Detector Modules. Packaging Processing. Bid on Equipment BR2517B 168 Diode Array & 166 Programmable Detector Modules Packaging Processing BECKMAN System Gold Detectors Beckman 166 and 168 Detector Modules address all of your ultra violet/ visible (UVNIS) detection

More information

PAL LSI - Robust and Reliable Sample Handling

PAL LSI - Robust and Reliable Sample Handling PAL LSI - Robust and Reliable Sample Handling The PAL System, ingeniously reliable, flexible and productive PAL LSI: Innovative features giving real benefits Easy maintenance and adaptation: The different

More information

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection Falcon Analytical makers of the... Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection John Crandall, President Ned Roques,

More information

OTHER FEATURES UNIQUE FEATURES

OTHER FEATURES UNIQUE FEATURES OTHER FEATURES H2 Generator + Zero Air Generator All-In-One Automatic Easy refill Cascading available up to 32 units PC Remote Software control via USB or RS232 Remote alarms/management Optional H2 sensor

More information

PAL LSI - Robust and Reliable Sample Handling

PAL LSI - Robust and Reliable Sample Handling PAL LSI - Robust and Reliable Sample Handling PAL LSI: Enhanced productivity due to innovative technology Large Sample Capacity: 162 x 2 ml-vials can be stored on one tray holder. The standard length PAL

More information

Finnigan PolarisQ User s Guide. PN , Revision D

Finnigan PolarisQ User s Guide. PN , Revision D Finnigan PolarisQ User s Guide PN 120014, Revision D 2004 Thermo Electron Corporation. All rights reserved. Printing History: Rev D, Oct 2004. Rev C, Sep 2004. Xcalibur, Finnigan TRACE DSQ, Finnigan FOCUS

More information

Software Operation Manual

Software Operation Manual Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA 4000 GC/MS Version 6 Software Operation Manual Varian, Inc. 2004-2009 Printed in U.S.A. 03-914999-00:Rev. 8 Trademark Acknowledgments Microsoft,

More information

PINMRF. Checkout Quiz - Varian Inova-300 Version

PINMRF. Checkout Quiz - Varian Inova-300 Version PINMRF Checkout Quiz - Varian Inova-300 Version Please carefully read every question and select the best answer(s). Some questions may have more than one correct answer. You must select all the correct

More information

TMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer

TMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer TECH TIP # 70 TMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer Introduction TR0070.0 Successful acquisition of quantitative tandem mass tag (TMT*) data with the Thermo Scientific LTQ-Orbitrap

More information

Technical Note. High-speed Agilent 1100 Series diode-array detector SL for optimization of resolution, sensitivity, spectral sensitivity and linearity

Technical Note. High-speed Agilent 1100 Series diode-array detector SL for optimization of resolution, sensitivity, spectral sensitivity and linearity High-speed Agilent Series diode-array detector SL for optimization of resolution, sensitivity, spectral sensitivity and linearity Technical Note Abstract This application has been verified using an Agilent

More information

Assay Creosote Extraction of Selected Posts from the 1958 Cooperative Test After 50 Years of Exposure as a Ground Contact Preservative

Assay Creosote Extraction of Selected Posts from the 1958 Cooperative Test After 50 Years of Exposure as a Ground Contact Preservative Assay Creosote Extraction of Selected from the 1958 Cooperative Test After 50 Years of Exposure as a Ground Contact Preservative David A. Webb Creosote Council Valencia, Pennsylvania Stacy A. McKinney

More information

SEM- EDS Instruction Manual

SEM- EDS Instruction Manual SEM- EDS Instruction Manual Double-click on the Spirit icon ( ) on the desktop to start the software program. I. X-ray Functions Access the basic X-ray acquisition, display and analysis functions through

More information

Performance. Reliability. Productivity. Automated Flash Chromatography Systems

Performance. Reliability. Productivity. Automated Flash Chromatography Systems Performance Reliability Productivity Automated Flash Chromatography Systems CombiFlash Rf+ Family of Purification Systems Flash chromatography is the science of refinement Teledyne Isco continues to refine

More information

Results of the June 2000 NICMOS+NCS EMI Test

Results of the June 2000 NICMOS+NCS EMI Test Results of the June 2 NICMOS+NCS EMI Test S. T. Holfeltz & Torsten Böker September 28, 2 ABSTRACT We summarize the findings of the NICMOS+NCS EMI Tests conducted at Goddard Space Flight Center in June

More information

UNITY 2 TM. Version 1.0. February 2008

UNITY 2 TM. Version 1.0. February 2008 UNITY 2 TM ULTRA 50:50 Operators Manual Version 1.0 February 2008 1. Loading tubes onto ULTRA 50:50...3 1.1. DiffLok analytical end caps for sample tubes...3 1.2. Capping tubes with DiffLok caps...3 1.3.

More information

MTL Software. Overview

MTL Software. Overview MTL Software Overview MTL Windows Control software requires a 2350 controller and together - offer a highly integrated solution to the needs of mechanical tensile, compression and fatigue testing. MTL

More information

Service. Nu Instruments Service & Upgrades. ICP-MS, GD-MS, IRMS, Noble Gas.

Service. Nu Instruments Service & Upgrades. ICP-MS, GD-MS, IRMS, Noble Gas. Service Nu Instruments Service & Upgrades ICP-MS, GD-MS, IRMS, Noble Gas www.nu-ins.com Nu Instruments Maintenance Contract Options Nu Instruments provides a range of post-warranty service solutions to

More information

ENGL 1302: CH. 3 & 5; INTRO. TO EXPLAINING ISSUE ESSAY

ENGL 1302: CH. 3 & 5; INTRO. TO EXPLAINING ISSUE ESSAY ENGL 1302: CH. 3 & 5; INTRO. TO EXPLAINING ISSUE ESSAY February 10, 2016 AGENDA / FYI Quiz ( 3 pts) Guess the fallacy Notes on Definition Introduction to Explaining an Issue / Concept essay Finish questions

More information

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO Model 207 Automatic GTAW Welding System 1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small

More information

Analyzing Impulse Noise with OneExpert CATV Ingress Expert

Analyzing Impulse Noise with OneExpert CATV Ingress Expert Application Note Analyzing Impulse Noise with OneExpert CATV Ingress Expert VIAVI Solutions Based on powerful OneExpert CATV HyperSpectrum technology, Ingress Expert s innovative overlapping FFT analysis

More information

M1 OSCILLOSCOPE TOOLS

M1 OSCILLOSCOPE TOOLS Calibrating a National Instruments 1 Digitizer System for use with M1 Oscilloscope Tools ASA Application Note 11-02 Introduction In ASA s experience of providing value-added functionality/software to oscilloscopes/digitizers

More information

Peak Detection with Varian MS Workstation for Varian 220 and 240 GCMS

Peak Detection with Varian MS Workstation for Varian 220 and 240 GCMS Peak Detection with Varian MS Workstation for Varian 220 and 240 GCMS by: Randall Bramston-Cook Lotus Consulting 5781 Campo Walk Long Beach, Ca 90803 310/569-0128 ebramstoncook@msn.com February 12, 2010

More information

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications Automated Flash Chromatography Systems Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications Speed Performance Reliability CombiFlash Rf - Making Fl Improve Your Productivity

More information

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper Products: ı ı R&S FSW R&S FSW-K50 Spurious emission search with spectrum analyzers is one of the most demanding measurements in

More information

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full. TENDER SPECIFICATIONS FOR THE SUPPLY, DELIVERY, INSTALLATION AND COMMISSIONING OF ONE UNIT OF VARIABLE PRESSURE ENVIRONMENTAL SCANNING ELECTRON MICROSCOPE (SEM) CUM ENERGY DISPERSIVE SPECTROSCOPY (EDS)

More information

Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1

Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1 International Conference on Applied Science and Engineering Innovation (ASEI 2015) Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1 1 China Satellite Maritime

More information

Understanding PQR, DMOS, and PSNR Measurements

Understanding PQR, DMOS, and PSNR Measurements Understanding PQR, DMOS, and PSNR Measurements Introduction Compression systems and other video processing devices impact picture quality in various ways. Consumers quality expectations continue to rise

More information

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK m RSC CHROMATOGRAPHY MONOGRAPHS Chromatographie Integration Methods Second Edition Norman Dyson Dyson Instruments Ltd., UK THE ROYAL SOCIETY OF CHEMISTRY Chapter 1 Measurements and Models The Basic Measurements

More information

INCA ENERGY EDS TRAINING. System Block Diagram. INCA Energy Software. Xiang Yang EM SMU. Navigators. Point & ID Navigator.

INCA ENERGY EDS TRAINING. System Block Diagram. INCA Energy Software. Xiang Yang EM SMU. Navigators. Point & ID Navigator. INCA ENERGY EDS TRAINING Xiang Yang EM Center @ SMU System Block Diagram INCA Energy Software Navigators Point & ID Navigator Data tree 1 Spectrum Export Bitmap TIFF JPEG Metafile EMSA ISIS Optimum Conditions

More information

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus: Controller menus 5500sc, 9610sc and 9611sc analyzers DOC273.53.80566 Introduction This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level

More information

Peak Detection with Varian Star Workstation for Varian 3800 and 450 Gas Chromatographs

Peak Detection with Varian Star Workstation for Varian 3800 and 450 Gas Chromatographs Peak Detection with Varian Star Workstation for Varian 3800 and 450 Gas Chromatographs by: Randall Bramston-Cook Lotus Consulting 5781 Campo Walk Long Beach, Ca 90803 310/569-0128 ebramstoncook@msn.com

More information

PulseCounter Neutron & Gamma Spectrometry Software Manual

PulseCounter Neutron & Gamma Spectrometry Software Manual PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN

More information

LHC Beam Instrumentation Further Discussion

LHC Beam Instrumentation Further Discussion LHC Beam Instrumentation Further Discussion LHC Machine Advisory Committee 9 th December 2005 Rhodri Jones (CERN AB/BDI) Possible Discussion Topics Open Questions Tune measurement base band tune & 50Hz

More information

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework 1.0 Purpose This technical procedure shall be followed for the operation of the Scanning

More information

CAEN Tools for Discovery

CAEN Tools for Discovery Viareggio March 28, 2011 Introduction: what is the SiPM? The Silicon PhotoMultiplier (SiPM) consists of a high density (up to ~10 3 /mm 2 ) matrix of diodes connected in parallel on a common Si substrate.

More information

ChromQuest 5.0 Chromatography Data System

ChromQuest 5.0 Chromatography Data System ChromQuest 5.0 Chromatography Data System User Guide for the SpectraSYSTEM LC CHROM-97256 Revision A March 2008 2008 Thermo Fisher Scientific Inc. All rights reserved. ChromQuest is a trademark of Thermo

More information

SPECIFICATION NO NOTE

SPECIFICATION NO NOTE NOTE The Model 207-1 is a special version of the standard M-207 Power Supply. It has been altered for a special applications requiring low current operation at high arc voltages in ambient and pressurized

More information

ih Series Drypumps (505) idealvac.com idealvac.com

ih Series Drypumps (505) idealvac.com idealvac.com ih Series Drypumps idealvac.com (505)872-0037 idealvac.com 1st Choice for Vacuum Solutions S 2 SEMICONDUCTOR INDUSTRY STANDARDS COMPLIANCE The ih Series Drypumps comply with internationally recognized

More information

MTS/T-BERD 8000 Platform

MTS/T-BERD 8000 Platform Key Features New optical design for field applications 50% reduction in size and weight for true OSNR measurements in ROADM networks Full spectral range of 1250 to 1650 nm for DWDM and CWDM testing High-resolution

More information

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules MTS/T-BERD platform Applications Provisioning and maintenance of ROADM networks Commissioning of DWDM

More information

Overview and Interpretation of D7900/D7169 Merge Analysis

Overview and Interpretation of D7900/D7169 Merge Analysis Overview and Interpretation of D7900/D7169 Merge Analysis Crude Oil Quality Association New Orleans, LA March 14, 2019 Value of Merged Simdis Analysis Requires very little sample (10-50 mls) Much faster

More information

The University of Texas at Austin September 30, 2011

The University of Texas at Austin September 30, 2011 SECTION 27 08 20 COPPER TESTING PART 1 - GENERAL 1.1 SUMMARY A. Test measurements shall be taken for all balanced-twisted pair cabling, including horizontal and backbone copper cables and wall-to-rack

More information

SUPPORTING INFORMATION

SUPPORTING INFORMATION SUPPORTING INFORMATION Freeze-thaw Sample Preparation Method Improves the Detection of Volatile Compounds in Insects Using Headspace Solid-Phase Microextraction (HS-SPME) Jian Chen USDA-ARS, National Biological

More information

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC FRACTION COLLECTOR Microcomputer Controlled CHF122SC From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses.

More information

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz Broadcast Product Brochure 02.00 R&S ETH Handheld TV Analyzer At a glance The R&S ETH handheld TV analyzer was specially designed

More information

Performing a Sound Level Measurement

Performing a Sound Level Measurement APPENDIX 9 Performing a Sound Level Measurement Due to the many features of the System 824 and the variety of measurements it is capable of performing, there is a great deal of instructive material in

More information

Processing data with Mestrelab Mnova

Processing data with Mestrelab Mnova Processing data with Mestrelab Mnova This exercise has three parts: a 1D 1 H spectrum to baseline correct, integrate, peak-pick, and plot; a 2D spectrum to plot with a 1 H spectrum as a projection; and

More information

Comparison Parameters and Speaker Similarity Coincidence Criteria:

Comparison Parameters and Speaker Similarity Coincidence Criteria: Comparison Parameters and Speaker Similarity Coincidence Criteria: The Easy Voice system uses two interrelating parameters of comparison (first and second error types). False Rejection, FR is a probability

More information

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it! Laser Beam Analyser Laser Diagnos c System If you can measure it, you can control it! Introduc on to Laser Beam Analysis In industrial -, medical - and laboratory applications using CO 2 and YAG lasers,

More information

Electrospray-MS Charge Deconvolutions without Compromise an Enhanced Data Reconstruction Algorithm utilising Variable Peak Modelling

Electrospray-MS Charge Deconvolutions without Compromise an Enhanced Data Reconstruction Algorithm utilising Variable Peak Modelling Electrospray-MS Charge Deconvolutions without Compromise an Enhanced Data Reconstruction Algorithm utilising Variable Peak Modelling Overview A.Ferrige1, S.Ray1, R.Alecio1, S.Ye2 and K.Waddell2 1 PPL,

More information

Section C Recorders. DPR mm Digital Strip Chart Recorder

Section C Recorders. DPR mm Digital Strip Chart Recorder 91-00-01-01 Section C Recorders Contents Product Type Literature No. Overview 40-00-02-02 LeaderLine PC Software 51-52-03-16 SCF Software Configuration Tool 51-52-03-26 SDA Software Data Analysis Tool

More information

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy D. Johnson, R. Westerman, M. DeVre, Y. Lee, J. Sasserath Unaxis USA, Inc. 10050 16 th Street North

More information

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0 CHEM 411L Instrumental Analysis Laboratory Revision 2.0 Noise In this laboratory exercise we will determine the Signal-to-Noise (S/N) ratio for an IR spectrum of Air using a Thermo Nicolet Avatar 360 Fourier

More information

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter Fully compliant to LXI Class C specification General Information Up to 8 power meter channels in a

More information

Department of Electrical & Electronic Engineering Imperial College of Science, Technology and Medicine. Project: Real-Time Speech Enhancement

Department of Electrical & Electronic Engineering Imperial College of Science, Technology and Medicine. Project: Real-Time Speech Enhancement Department of Electrical & Electronic Engineering Imperial College of Science, Technology and Medicine Project: Real-Time Speech Enhancement Introduction Telephones are increasingly being used in noisy

More information

NGC8206 Start-Up Guide

NGC8206 Start-Up Guide NGC8206 Start-Up Guide MEASUREMENT & CONTROL SYSTEMS Intellectual Property & Copyright Notice 2010 by ABB Inc., Totalflow Products ( Owner ), Bartlesville, Oklahoma 74006, U.S.A. All rights reserved. Any

More information

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity Print Your Name Print Your Partners' Names Instructions August 31, 2016 Before lab, read

More information

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16] UNIT-3 Part A 1. What is CFAR loss? [ N/D-16] Constant false alarm rate (CFAR) is a property of threshold or gain control devices that maintain an approximately constant rate of false target detections

More information

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer solvents) Updated November 14, 2017 Instrument instructions can be found at: http://academic.bowdoin.edu/chemistry/resources/instructions.shtml

More information

Waters Synapt High Definition Mass Spectrometry System Quick Start Guide

Waters Synapt High Definition Mass Spectrometry System Quick Start Guide Waters Synapt High Definition Mass Spectrometry System Quick Start Guide 71500129903/Revision B Copyright Waters Corporation 2007 All rights reserved Copyright notice 2007 WATERS CORPORATION. PRINTED IN

More information

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency CATHODE RAY OSCILLOSCOPE Basic block diagrams Principle of operation Measurement of voltage, current and frequency 103 INTRODUCTION: The cathode-ray oscilloscope (CRO) is a multipurpose display instrument

More information

System Requirements SA0314 Spectrum analyzer:

System Requirements SA0314 Spectrum analyzer: System Requirements SA0314 Spectrum analyzer: System requirements Windows XP, 7, Vista or 8: 1 GHz or faster 32-bit or 64-bit processor 1 GB RAM 10 MB hard disk space \ 1. Getting Started Insert DVD into

More information

SPEAR 3: Operations Update and Impact of Top-Off Injection

SPEAR 3: Operations Update and Impact of Top-Off Injection SPEAR 3: Operations Update and Impact of Top-Off Injection R. Hettel for the SSRL ASD 2005 SSRL Users Meeting October 18, 2005 SPEAR 3 Operations Update and Development Plans Highlights of 2005 SPEAR 3

More information

MAutoPitch. Presets button. Left arrow button. Right arrow button. Randomize button. Save button. Panic button. Settings button

MAutoPitch. Presets button. Left arrow button. Right arrow button. Randomize button. Save button. Panic button. Settings button MAutoPitch Presets button Presets button shows a window with all available presets. A preset can be loaded from the preset window by double-clicking on it, using the arrow buttons or by using a combination

More information

Using the BHM binaural head microphone

Using the BHM binaural head microphone 11/17 Using the binaural head microphone Introduction 1 Recording with a binaural head microphone 2 Equalization of a recording 2 Individual equalization curves 5 Using the equalization curves 5 Post-processing

More information

MestReNova Manual for Chem 201/202. October, 2015.

MestReNova Manual for Chem 201/202. October, 2015. 1. Introduction to 1-D NMR Data Processing with MestReNova The MestReNova program can do all of the routine NMR data processing needed for Chem 201 and 202 and will be available through the Reed downloads

More information

Data Sheet. HDSP-70xE 17.3 mm (0.68 inch) General Purpose 5x7 Dot Matrix Alphanumeric Displays

Data Sheet. HDSP-70xE 17.3 mm (0.68 inch) General Purpose 5x7 Dot Matrix Alphanumeric Displays HDSP-7xE 17.3 mm (.8 inch) General Purpose x7 Dot Matrix Alphanumeric Displays Data Sheet HDSP-7xE Series, HDSP-71xE Series HDSP-7xG Series, HDSP-71xG Series HDSP-7xA Series, HDSP-71xA Series Description

More information

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B ) SMARTSCAN 8000 PLUS LIGHT CURTAIN 1 Unpacking 8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/0160306 CD206B160306 ) Remove all packaging material and retain it Locate and keep the delivery

More information

Liquid Mix Plug-in. User Guide FA

Liquid Mix Plug-in. User Guide FA Liquid Mix Plug-in User Guide FA0000-01 1 1. COMPRESSOR SECTION... 3 INPUT LEVEL...3 COMPRESSOR EMULATION SELECT...3 COMPRESSOR ON...3 THRESHOLD...3 RATIO...4 COMPRESSOR GRAPH...4 GAIN REDUCTION METER...5

More information

semi-automated scanning

semi-automated scanning semi-automated scanning The X-Rite EasyTrax semi-automated scanning solution is a great tool for our short and long run book cover manufacturing process. We are excited that it quickly targets color and

More information

Sample Analysis Design. Element2 - Basic Software Concepts (cont d)

Sample Analysis Design. Element2 - Basic Software Concepts (cont d) Sample Analysis Design Element2 - Basic Software Concepts (cont d) Samples per Peak In order to establish a minimum level of precision, the ion signal (peak) must be measured several times during the scan

More information

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. Multichannel Scaler Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. The ideal solution for: Time-resolved single-photon counting Phosphorescence lifetime spectrometry Atmospheric and

More information

SMS3000X Series Spectrum Analyzer

SMS3000X Series Spectrum Analyzer Data Sheet SMS3000X Series Spectrum Analyzer SMS3032X SMS3021X General Description SMS3000X series spectrum analyzer has a frequency range from 9 khz up to 2.1 GHz/3.2 GHz, it is light weight and small

More information

Operating pressure should be 6000 psi or better suitable for both analytical and semi-preparative applications

Operating pressure should be 6000 psi or better suitable for both analytical and semi-preparative applications S. No. NIPER-G/PUR/GLOBAL/2018/01 Technical Specification for Analytical HPLC with PDA & Fluorescence detector Fully automated analytical high performance liquid chromatography system with single point

More information

A New "Duration-Adapted TR" Waveform Capture Method Eliminates Severe Limitations

A New Duration-Adapted TR Waveform Capture Method Eliminates Severe Limitations 31 st Conference of the European Working Group on Acoustic Emission (EWGAE) Th.3.B.4 More Info at Open Access Database www.ndt.net/?id=17567 A New "Duration-Adapted TR" Waveform Capture Method Eliminates

More information

Agilent PN Time-Capture Capabilities of the Agilent Series Vector Signal Analyzers Product Note

Agilent PN Time-Capture Capabilities of the Agilent Series Vector Signal Analyzers Product Note Agilent PN 89400-10 Time-Capture Capabilities of the Agilent 89400 Series Vector Signal Analyzers Product Note Figure 1. Simplified block diagram showing basic signal flow in the Agilent 89400 Series VSAs

More information

High Power ARNS/IFF Limiter Module: Ultra Low Flat Leakage & Fast Recovery Time

High Power ARNS/IFF Limiter Module: Ultra Low Flat Leakage & Fast Recovery Time RELEASED RFLM-961122MC-299 High Power ARNS/IFF Limiter Module: Ultra Low Flat Leakage & Fast Recovery Time Features: SMT Limiter Module: 8mm x 5mm x 2.5mm Frequency Range: 960 MHz to 1,215 MHz High Average

More information

Signal Stability Analyser

Signal Stability Analyser Signal Stability Analyser o Real Time Phase or Frequency Display o Real Time Data, Allan Variance and Phase Noise Plots o 1MHz to 65MHz medium resolution (12.5ps) o 5MHz and 10MHz high resolution (50fs)

More information

FEASIBILITY STUDY OF USING EFLAWS ON QUALIFICATION OF NUCLEAR SPENT FUEL DISPOSAL CANISTER INSPECTION

FEASIBILITY STUDY OF USING EFLAWS ON QUALIFICATION OF NUCLEAR SPENT FUEL DISPOSAL CANISTER INSPECTION FEASIBILITY STUDY OF USING EFLAWS ON QUALIFICATION OF NUCLEAR SPENT FUEL DISPOSAL CANISTER INSPECTION More info about this article: http://www.ndt.net/?id=22532 Iikka Virkkunen 1, Ulf Ronneteg 2, Göran

More information

New Filling Pattern for SLS-FEMTO

New Filling Pattern for SLS-FEMTO SLS-TME-TA-2009-0317 July 14, 2009 New Filling Pattern for SLS-FEMTO Natalia Prado de Abreu, Paul Beaud, Gerhard Ingold and Andreas Streun Paul Scherrer Institut, CH-5232 Villigen PSI, Switzerland A new

More information