1. Technology: Solar PV 2. Maximum Power: 50 kw 3. Contribution to fault levels: N/A 4. Size & rating of the relevant Transformer: N/A 5.

Size: px
Start display at page:

Download "1. Technology: Solar PV 2. Maximum Power: 50 kw 3. Contribution to fault levels: N/A 4. Size & rating of the relevant Transformer: N/A 5."

Transcription

1 1. Technology: Solar PV 2. Maximum Power: 50 kw 3. Contribution to fault levels: N/A 4. Size & rating of the relevant Transformer: N/A 5. Single line diagram: refer to following page 6. Systems & Communication Systems: refer to following page 7. Voltage Control and reactive power capability: N/A 8. Details specific to the location of facility: N/A

2 Clean Technology Partners print on recycled paper. Please print on recycled paper. ROOFTOP MSSB, PV-DB & INVERTERS LOCATION MAIN SWITCHBOARD LOCATION KIOSK TX LOCATION 10mm² 4C+E ~5 m PV ARRAY 01 (See Note 5) PV ARRAY 02 (See Note 5) Rooftop DC Isolators Rooftop DC Isolators INV-01 - Fronius Eco S AS4777 MAINS INV-02 - Fronius Eco S AS4777 MAINS 50A 3Ph/3P AC-ISO-01 (Note 2) 50A 3Ph/3P AC-ISO-02 (Note 2) PV-DB 50A 3P Type C MCB 50A 3P Type C MCB Mains Relay ComAp 80A 3P N/O Contactor Relay Functions 27, 59, 81H, 81L, 78, 81R, 47 80A 3P Main Isolator 4x1C+E 25mm² ~25 m Existing Sub-Ccts MSSB SOLAR SUPPLY MAIN SWITCH () 450A 80A 3P Merlin Gerin CB 4x1C 240mm² ~25m Existing Sub-Mains and Sub-Ccts MSB Site Main Switch Earth Electrode Meter Panel kwh 2x4x1C 400mm² Cu/XLPE (X-90) ~55m Upgrade Existing Meter to Bi-Directional Type. Liaise with Supply Authority Electricity Network Bond PV Frames & Framework To Earth Connection From Main Switchboard Earth Bar (Note 3) Components Component Description Quantity Jinko JKM250P-60-A PV Modules 240 Fronius Eco S INV-0X 2 80A 3P Merlin Gerin CB Solar Main Switch 1 PVDB with Relay PV-DB 1 50A 3P AC-ISO-0X 2 IP56 DC Combiner Box with 1000Vdc 15A Fuses (1 per Inv.) DC Junction Box 2 IPD ZFV32 DC Isolator (1 per String) DC Isolator 10 PV SYSTEM DETAILS PV TYPE: Jinko JKM250P-60-A MODULE SIZE: 1650x992x40mm No. MODULES: 240 TOTAL kwp: kwp ARRAY PITCH: Varies ORIENTATION: Varies Do not scale from this drawing. Always check dimensions on site before using any information contained within this drawing. All dimensions shown are indicative only and need to be verified on-site, Clean Technology Partners accepts no liability from errors or omissions shown on this drawing. Check this drawing is the latest version. Do not reproduce all or part of this drawing without prior consent. Client: FOR APPROVAL Notes: 1. All installation works shall comply with; AS3000, AS3008, AS5033, AS4777, CEC Guidelines, Supply Authority Service & Installation Rules and local authority guidelines. 2. All AC isolators shall be load break type. AC isolators installed externally shall be min IP65. An AC isolator is not required if the inverter is in line of sight of the PV-DB, where the inverter CB can be used for isolation. 3. Utilise WEEB washers and bond all array frames with earth cabling ensuring a continuous earth connection Project: even with the removal of a PV module. 4. Ensure system is labelled to AS5033, AS4777.1, CEC guidelines and relevant state requirements. 5. Some DC details have been omitted for clarity. Title: 6. Installer is to verify cable runs onsite. Installation method assumed to be 'unenclosed spaced' for Inverters sub-mains and 'unenclosed spaced' for PV-DB sub-mains. If any variations from the runs or installation method are required onsite, please contact CTP for guidance on cable sizing. Dwg No: Rev: PV AC Electrical Schematic J A1 A1 12/01/16 For Approval Issue Rev Date Comments Dwn Chkd Dwn: Chkd: Date: 12/01/16 Job No: J-1292 Scale: NTS@A3 Clean Technology Partners Pty Ltd

3 A 22 A A-A LABEL SCHEDULE LOCATION REF ENGRAVED LABEL TEXT HEIGHT COLOR FIXING LABEL SIZE WxH QTY

4 PERFORMANCE DATA OUTGOING PROTECTION RELAY PERFORMANCE sq mm CABLES 21 N 16 sq mm CABLES EQUIPMENT SCHEDULE PART ID PART NO. EQUIPMENT DE SCRIPTION QTY INCOMING

5 MAIN SWITCHBOARD LOAD ANSI PROTECTION TABLE FROM PV SYSTEM

INSTALLATION AND OPERATION M

INSTALLATION AND OPERATION M INSTALLATION AND OPERATION M RUBYSTAR INSTALLATION AND OPERATION MANUAL Safety Instructions : Only authorised installers should install and or replace Rubystar inverters. Ensure that all electrical installations

More information

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: ICAO: IEC: 61822 CENELEC: AC 150/5345-10 (current edition), L-828, L-829. Aerodrome Design Manual Part 5, para. 3.2 (current

More information

Toronto Hydro - Electric System

Toronto Hydro - Electric System Toronto Hydro - Electric System FIT Commissioning Requirements and Reports Comments and inquiries can be e-mailed to: FIT@torontohydro.com Customers without e-mail access can submit through regular mail

More information

The Three-Phase Inverter Not Only for Your Home...

The Three-Phase Inverter Not Only for Your Home... SUNNY TRIPOWER 5000TL 12000TL STP 5000TL-20 / STP 6000TL-20 / STP 7000TL-20 / STP 8000TL-20 / STP 9000TL-20 / STP 10000TL-20 / STP 12000TL-20 NEW available as 10 kva and 12 kva versions Economical Flexible

More information

OxLinx TM LHM-Pxxx. Classification : Technical Specification. Ⅰ. Preview. Ⅱ. Contents. Spec. No. AD K Date

OxLinx TM LHM-Pxxx. Classification : Technical Specification. Ⅰ. Preview. Ⅱ. Contents. Spec. No. AD K Date Classification : OxLinx TM LHM-Pxxx Spec. No. AD150320-K01-001 Date 2015.06.19 Version AOC Dev. Part Written Team JW Kim Ⅰ. Preview Group HDMI Active Optical Cable Connector type # 4K 30Hz, 3D,

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL STP 8000TL-10 / STP 10000T-10 / STP 12000TL-10 / STP 15000TL-10 / STP 17000TL-10 SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL Economical Reliable Flexible Simple Maximum efficiency of

More information

String Inverters SUN 2000-KTL, IA240 Series, EM24 DIN, CTD-1X,

String Inverters SUN 2000-KTL, IA240 Series, EM24 DIN, CTD-1X, Product Certificate Number Applicant 11630-CER Huawei Technologies España Parque Empresarial Las Tablas, Federico Mompou 5, Ed. 1 planta 2 28050 Las Tablas. Madrid, Spain. Series Model/ Variant models

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

Prior List of Eligible Inverters Valid Only Until March 31, 2005

Prior List of Eligible Inverters Valid Only Until March 31, 2005 Prior List of Eligible s Valid Only Until March 31, 2005 California Energy Commission Emerging Renewables Program Manufacturer Name Alpha Technologies, Inc. Alpha Technologies, Inc. Beacon Power Bergey

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

AF-300 E11 Adjustable Frequency Drive

AF-300 E11 Adjustable Frequency Drive AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed

More information

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL Installation and programming Manual v2.2 1 MARSS Solar Defender SYSTEM This guidebook provides the essential instructions to install and configure the

More information

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT...

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT... TABLE OF CONTENTS 1. OVERVIEW... 1 2. INSTALLATION... 3 2.1. 500DA-3G CONNECTIONS... 3 3. SPECIFICATIONS... 4 3.1. SERIAL VIDEO INPUT... 4 3.2. SERIAL VIDEO OUTPUT... 4 3.3. ELECTRICAL... 4 3.4. PHYSICAL...

More information

HDMI Extender via Single SC Fiber Support 3D/4K2K Up to 200m in one Single-mode Fiber

HDMI Extender via Single SC Fiber Support 3D/4K2K Up to 200m in one Single-mode Fiber Description HDMI (High-Definition Multimedia Interface) recently has become increasingly popular in the application of video and audio transmission system. In view of the extreme of electrical performances,

More information

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber Description HDMI (High-Definition Multimedia Interface) recently has become increasingly popular in the application of video and audio transmission system. In view of the extreme of electrical performances,

More information

Switching Power Module

Switching Power Module Assembled in U.S.A. 5005757 Rev. A GCU-HOSP 243C ID. COT. EQ. IEC PEV /EC Class 2 +.800.523.9466 + 44.(0)20.7680.448 HomeWorks DI Power odule Switching Power odule The Switching Power odule family is a

More information

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories Circuit Breakers BZM Product Information Circuit Breaker BZM1 16 to 125 A Circuit Breaker BZM2 125 to 250A BZM1 & BZM2 Accessories Circuit breakers BZM1 3-pole Rated current Short circuit Basic switching

More information

OT 100/ /700 P5

OT 100/ /700 P5 OT 100/120 277/700 P5 OPTOTRONIC Outdoor Constant current LED drivers Areas of application _ Street and urban lighting _ Industry _ Suitable for luminaires of protection class I Product benefits _ High

More information

2W SDARS ECHO Repeater

2W SDARS ECHO Repeater DATA SHEET Boosts SXM Signal Near WCS Sites Adjustable Gain to +93 db 2W High Power Output High Linearity Good Reverse Isolation High reliability ALC Protection Mounting Bracket accommodates mounting of

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

ECS COMBINED CUT-OUT AND CT CHAMBER INSTALLATION

ECS COMBINED CUT-OUT AND CT CHAMBER INSTALLATION Document Number: ECS 13-0080 Network(s): Summary: ENGINEERING CONSTRUCTION STANDARD ECS 13-0080 COMBINED CUT-OUT AND CT CHAMBER INSTALLATION EPN, LPN, SPN This standard details the procedure for installing

More information

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic

More information

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION VIDEO CONNECTIONS GENERAL PURPOSE INPUTS & OUTPUTS SPECIFICATIONS...

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION VIDEO CONNECTIONS GENERAL PURPOSE INPUTS & OUTPUTS SPECIFICATIONS... TABLE OF CONTENTS 1. OVERVIEW...1 2. INSTALLATION...3 2.1. VIDEO CONNECTIONS... 3 2.2. GENERAL PURPOSE INPUTS & OUTPUTS... 4 3. SPECIFICATIONS...6 3.1. SERIAL DIGITAL VIDEO INPUTS... 6 3.2. SERIAL DIGITAL

More information

HD-CM HORIZON DIGITAL CABLE METER

HD-CM HORIZON DIGITAL CABLE METER HD-CM OFF! Max RF i/p = +17dBm 75Ω Max AC/DC i/p = 120Vrms MENU INPUT ON HORIZON DIGITAL CABLE METER Horizon Global Electronics Ltd. Unit 3, West Side Flex Meadow Harlow, Essex CM19 5SR Phone: +44(0) 1279

More information

SolarEdge Instruction - California Electric Rule 21

SolarEdge Instruction - California Electric Rule 21 Version 1.6, Mar 2019 1 SolarEdge Instruction - California Electric Rule 21 Version History Version 1.6, March 2019: Rule 21 phase 3 adaptation Version 1.5, Aug 2018: Simplified inverter configuration

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

CAMTO LTD. Arc detecting system DC/AC

CAMTO LTD. Arc detecting system DC/AC CAMTO LTD Arc detecting system DC/AC Arc detecting system DC/AC The system is based on experience with arc protection since 1962. The system units are built into boxes that all fit on a 35 mm DIN-rail.

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

Model /29S RF Splitter

Model /29S RF Splitter Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

New Solar Homes Partnership Flexible Installation Calculator User Guide

New Solar Homes Partnership Flexible Installation Calculator User Guide New Solar Homes Partnership Flexible Installation Calculator User Guide Updated October 12, 2017 Table of Contents New Solar Homes Partnership Flexible Installation Calculator User Guide... 1 Introduction...

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2008-05-07 Page 1 of 8 Report Reference # E320635-A1-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

LED Backlight for Technics amplifiers

LED Backlight for Technics amplifiers LED Backlight for Technics amplifiers Technics SE-A900S Technics SE-A900SM2 Technics SE-A909S Technics SE-A1000 Technics SE-A1000M2 Technics SE-A1010 Rev. 1.2 B Description The LED module is designed to

More information

TRFM Series RF Amplifier Module

TRFM Series RF Amplifier Module Doc. 2272065, Rev. C TIARRA Optical Node TRFM Series RF Amplifier Module Contents Equipment Description... 39 Model Names... 41 Functional Description... 43 Return RF Signal Flow... 45 Controls and Connectors...

More information

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...

More information

HDMI Extender Via One MPO Fiber MPO Connector Extends HDMI Link Up To 200 Meters

HDMI Extender Via One MPO Fiber MPO Connector Extends HDMI Link Up To 200 Meters Description APAC s AH-UD-200-MPO optical extender provides a high quality and uncompressed HDMI data link between source and sink devices. Go though the optical fiber technologies, this extender can enable

More information

PRELIMINARY Sunny Boy 240-US

PRELIMINARY Sunny Boy 240-US PRELIMINARY Sunny Boy 240-US SB 240-US-10 Optimized reliability Simple installation Unrivaled monitoring SMA-backed security Multigate technology allows for reduced component count Private band powerline

More information

LONWORKS Fibre Optic Router

LONWORKS Fibre Optic Router LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS

More information

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1) 80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,

More information

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters Signal Conditioners Highlights Battery powered Line powered Multi-purpose Modular-style Multi-channel Charge & impedance converters Industrial charge amplifiers & sensor simulators PCB Piezotronics, Inc.

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

relays Electromechanical 2006 /2007

relays Electromechanical 2006 /2007 1 Electromechanical relays 2006 /2007 miniature relays industrial relays automotive relays interface relays plug-in sockets and accessories 2 Relays and Sensors - our business! Established in 1935 to manufacture

More information

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS 71346 LED Floodlight RoHS OVERALL LAMP PARAMETERS LED DRIVER LED Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage Output

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

WC-2100 WORD CLOCK DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL

WC-2100 WORD CLOCK DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL WC-2100 WORD CLOCK DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL SIGMA ELECTRONICS, INC. P.O. Box 448 1027 COMMERCIAL AVE. EAST PETERSBURG, PA 17520-0448 (717) 569-2681 WC-2100 WORK CLOCK DISTRIBUTION AMPLIFIER

More information

Automatic Changeover Unit ECO8000 Datasheet

Automatic Changeover Unit ECO8000 Datasheet Automatic Changeover Unit ECO8000 Datasheet The ECO8000 is a highly versatile automatic sync and signal changeover unit with configurations and capabilities required to address modern master sync application

More information

XT-17M-B relay - Delay-off, 1 C/O, 16 A

XT-17M-B relay - Delay-off, 1 C/O, 16 A - Delay-off, 1 C/O, 16 A Datasheet Features Delay-off Single function Time ranges: XT-17M-B1 0.1...1 s XT-17M-B2 1...10 s XT-17M-B3 6...60 s XT-17M-B4 1...10 min XT-17M-B5 6...60 min XT-17M-B6 1...10 h

More information

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection... IEC ors and Starters. Contents Description Catalog Number Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications..........

More information

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA PC-250 SMD Taped Parts Counter Operator s Manual ISO 9001:2008 Certified V-TEK, Incorporated 751 Summit Avenue Mankato, MN 56001 USA (P) 507-387-2039 (F) 507-387-2257 www.vtekusa.com Dear Customer: All

More information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Installation. SAPTF33xx-1xx in the Network. Standard Configuration SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device

More information

Identification - electrical services

Identification - electrical services Identification - electrical services Aesthetic All live phase cable sheathing to be brown coloured and neutral phase cable sheathing to be blue coloured, all labelled L1, L2, L3 & N respectively in accordance

More information

Telephony Training Systems

Telephony Training Systems Telephony Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 07/2018 Table of Contents General Description 2 Topic Coverage 6 Features & Benefits 6 List of Available Training Systems

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

Automatic Changeover Unit ECO8020 Datasheet

Automatic Changeover Unit ECO8020 Datasheet Automatic Changeover Unit ECO8020 Datasheet The ECO8020 is a highly versatile automatic sync and signal changeover unit with configurations and capabilities required to address modern master sync application

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

20Wrms DVB-T/60W ps UHF Amplifier

20Wrms DVB-T/60W ps UHF Amplifier 20Wrms DVB-T/60W ps UHF Amplifier UA60-R is a full LD-MOS Broadcast Power Amplifier designed for both digital and analog applications. The unit is the state of the art in terms of easy assembly, reliability

More information

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling! Medium Speed Network Terminal Box Supports dynamic measurement at medium-speed synchronous sampling! Decentralized arrangement and synchronous sampling of all channels. Medium Speed Network Terminal Box

More information

Form C: Type Test Verification Report

Form C: Type Test Verification Report Form C: Type Test Verification Report Type Approval and Manufacturer declaration of compliance with the requirements of G98. This form should be used when making a Type Test submission to the Energy Networks

More information

GEKCO SUBCARRIER REFERENCE OSCILLATOR MODEL SRO10 OPERATION/SERVICE MANUAL

GEKCO SUBCARRIER REFERENCE OSCILLATOR MODEL SRO10 OPERATION/SERVICE MANUAL GEKCO MODEL SRO10 SUBCARRIER REFERENCE OSCILLATOR OPERATION/SERVICE MANUAL GEKCO Labs PO Box 642 Issaquah, WA 98027 (425) 392-0638 P/N 595-431 REV 5/98 Copyright c 1998 GEKCO Labs All Rights Reserved Printed

More information

Corsair RM650x. High Performance Power. $ USD Pre-Order Option. No Product Imagery. Embargo Date 09/29/2015 First Customer Ship Date 09/29/2015

Corsair RM650x. High Performance Power. $ USD Pre-Order Option. No Product Imagery. Embargo Date 09/29/2015 First Customer Ship Date 09/29/2015 Embargo Date 09/29/2015 First Customer Ship Date 09/29/2015 Product Full Name CORSAIR RM650x Product Title High Performance Power Supply Part Number/ UPC See Below MSRP $119.99 USD Pre-Order Option No

More information

Corsair RM750x. High Performance Power. $ USD Pre-Order Option. No Product Imagery. Embargo Date 09/29/2015 First Customer Ship Date 09/29/2015

Corsair RM750x. High Performance Power. $ USD Pre-Order Option. No Product Imagery. Embargo Date 09/29/2015 First Customer Ship Date 09/29/2015 Embargo Date 09/29/2015 First Customer Ship Date 09/29/2015 Product Full Name CORSAIR RM750x Product Title High Performance Power Supply Part Number/ UPC See Below MSRP $129.99 USD Pre-Order Option No

More information

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications. MIRAL The Admiral Type family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications. Its features include: Extremely easy connection and

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

Case analysis: An IoT energy monitoring system for a PV connected residence

Case analysis: An IoT energy monitoring system for a PV connected residence Case analysis: An IoT energy monitoring system for a PV connected residence Marcus André P. Oliveira, 1, Wendell E. Moura Costa 1, Maxwell Moura Costa 1, 1 IFTO Campus Palmas marcusandre@ifto.edu.br, wendell@ifto.edu.br,

More information

Media Tube CW x 48.5mm 1.12 x mm mm mm kg 5.1lbs. 1.6kg 3.5lbs

Media Tube CW x 48.5mm 1.12 x mm mm mm kg 5.1lbs. 1.6kg 3.5lbs Date: Quantity: Company: Project: Media Tube CW The Traxon Media Tube CW is an IP66/IP67-rated slim LED tube for any wall or façade media lighting. Available in 295mm, 495mm, 995mm, and 1495mm lengths,

More information

Ps Black (typ.) (typ.) Current Consumption

Ps Black (typ.)  (typ.) Current Consumption 10Wrms DVB-T/20W ps UHF Amplifier AU20-DHG is a full LD-MOS Broadcast Power Amplifier designed for both digital and analog applications. The unit is the state of the art in terms of easy assembly, reliability

More information

Sunny Boy 1.5 / 2.5. Sunny Boy 1.5 / 2.5. The new standard for small PV systems. Communicative. Future-Proof. Flexible.

Sunny Boy 1.5 / 2.5. Sunny Boy 1.5 / 2.5. The new standard for small PV systems. Communicative. Future-Proof. Flexible. Sunny Boy 1.5 / 2.5 SB 1.5-1VL-40 / SB 2.5-1VL-40 Flexible Communicative Future-Proof Easy to Use Broad input voltage range Integrated WLAN and Speedwire/ Webconnect interface with Webconnect function

More information

CCL-S / CCT / CCL-P CUSTOM DESIGN RGB LCD DISPLAY BOARD PROGRAMMING AND INSTALLATION MANUAL VERSION: 1.2

CCL-S / CCT / CCL-P CUSTOM DESIGN RGB LCD DISPLAY BOARD PROGRAMMING AND INSTALLATION MANUAL VERSION: 1.2 -S / CCT / -P CUSTOM DESIGN RGB LCD DISPLAY BOARD PROGRAMMING AND INSTALLATION MANUAL VERSION: 1.2 AYBEY ELEKTRONIK GmbH Lothringer Allee 2 44805 Bochum Germany T: +49 (0) 234 687 36 82 9 G: +49 (0) 176

More information

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

UA70-R. 20W Ps IMD < -47dB Red Field (without precorrection) 10Wrms shoulder < -36dBc (with precorrection)

UA70-R. 20W Ps IMD < -47dB Red Field (without precorrection) 10Wrms shoulder < -36dBc (with precorrection) 10Wrms DVB-T/20W ps UHF Amplifier UA70-R is a full LD-MOS Broadcast Power Amplifier designed for both digital and analog applications. The unit is the state of the art in terms of easy assembly, reliability

More information

CDP-0, CDP-G, CDP-DUO INSTRUCTION MANUAL (M B)

CDP-0, CDP-G, CDP-DUO INSTRUCTION MANUAL (M B) Dynamic power control -0, -G, -DUO INSTRUCTION MANUAL (M98250001-03-17B) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could

More information

Instruction Manual Model BlockUpconverter

Instruction Manual Model BlockUpconverter Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

Solis Export Power Manager

Solis Export Power Manager Solis Export Power Manager Installation and Operation Manual Ningbo Ginlong Technologies Co., Ltd. No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 3572, P.R.China Tel: +86 (0)574

More information

Getting started with

Getting started with PART NO. CMA11 3 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption & Solar PV generation monitoring single phase, for homes fitted

More information

DSIM-GI Installation Guide Revision P

DSIM-GI Installation Guide Revision P Installation Guide Revision P 1. Quick Start Instructions for Single Pilot AGC Operatation 1. With the ADU jumper in Auto position, turn ADU pot to MIN amplifier output level. Then place the ADU jumper

More information

FMMX9000 DATA SHEET. Field Replaceable SMA IQ Mixer From 4 GHz to 8.5 GHz With an IF Range From DC to 3.5 GHz And LO Power of +15 dbm.

FMMX9000 DATA SHEET. Field Replaceable SMA IQ Mixer From 4 GHz to 8.5 GHz With an IF Range From DC to 3.5 GHz And LO Power of +15 dbm. FMMX9 Field Replaceable SMA IQ Mixer From 4 GHz to 8.5 GHz With an IF Range From DC to 3.5 GHz And LO Power of +15 dbm FMMX9 is an I/Q double balanced millimeter-wave mixer module that operates across

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

X-Band Redundant LNB Systems

X-Band Redundant LNB Systems X-Band Redundant LNB Systems BRX-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C) (Rev. C) Multi fuel / multi flame detector system Two - Systems - In - One Application: - Industrial and large utility boilers - NG, BFG, Oil, Orimulsion and pulverized coal burners Dual channel flame

More information

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

STD800LED Large display panel for photovoltaic systems

STD800LED Large display panel for photovoltaic systems STD800LED Large display panel for photovoltaic systems Installation instructions SolarWorld. And EveryDay is a SunDay. www.solarworld.de Table of Contents 1 Introduction 3 2 Safety 4 3 Installation of

More information

Indoor Linear 80W Driver SI-C215280N2KR

Indoor Linear 80W Driver SI-C215280N2KR Product Data Sheet Rev.00 2017. 2. 9 1# LED Driver Indoor Linear 80W Driver SI-C215280N2KR Constant Current LED Driver Features & Benefits Output Current Range: 1550mA Output Voltage Range: MAX 51 Vdc

More information

Ku-Band Redundant LNB Systems

Ku-Band Redundant LNB Systems Ku-Band Redundant LNB Systems BRK-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

A new generation of access control.

A new generation of access control. TM A new generation of access control. 2 or 4 Door Expandable Controller INSTALLATION MANUAL Installation overview: Installation Diagram Switch Alpha 4 Alpha 4 + PoE Alpha 4 + PoE Alarm central Accessory

More information

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters Description 3G-SDI (3G Serial Digital Interface) recently has become increasingly popular in the application of video and audio transmission system. However, the traditional copper wire cable imposes limits

More information

INDICATOR LAMPS & LED REPLACEMENT LAMPS

INDICATOR LAMPS & LED REPLACEMENT LAMPS INDICATOR LAMPS & LED REPLACEMENT LAMPS Neon indicators (internal resistor) 120VAC 55-452-0 Red lens 120VAC 55-453-0 Amber lens 120VAC 55-455-0 Green lens 120VAC Neon indicators (internal resistor) 120VAC

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

llen-bradley 194R-HM4-NFPA3

llen-bradley 194R-HM4-NFPA3 Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information