Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.
|
|
- Albert Mosley
- 6 years ago
- Views:
Transcription
1 Thermoacoustics Technical Brochure Product Line for Combustion Dynamics on Gas Turbine
2 Modular Measuring Chains. This technical brochure provides an overview how the various system components of the Kistler thermoacoustics product line can be combined to form complete measuring chains for typical application scenarios. Various measuring chain configurations for operation in non explosive environments (Non-Ex) and in potentially explosive atmospheres ('Ex-nA' non sparking and 'Ex-ia' intrinsically safe) are explained in detail. Non-Ex p Type 6021A..., 6023A..., 6025A... Softline Cable Differrential Charge Amplifier Type 5181A... DA System Non-Sparking (Ex-nA) Hazardous area (ATEX Zone 2) Non-hazardous area Type 6021AE..., 6023AE..., 6025AE... Softline Cable Differential Charge Amplifier 5185A... DA System Intrinsically Safe (Ex-ia) Hazardous area Non-hazardous area ATEX Zone 0, 1 or 2 ATEX Zone 1 or 2 Type 6021AE..., 6023AE..., 6025AE... Softline Cable Differential Charge Amplifier 5183A... Ex-barrier DA System 2
3 High-Temperature Pressure s. Kistler's durable sensors based on proprietary PiezoStar crystal material have been developed specifically for high-temperature environments of up to 700 C. 36,7 5,1 9 Type ,01 0,03 9, ,01 0,03 9 GND 53,6 40,7 5,1 Key Features 19, ,01 0,03 49,7 24,8 5 12,3 Type 6023 Operating temperature range C / F Integrated mineral insulated hardline cable Differential signal output, 2-wire system Acceleration compensated High natural frequency >50 khz Internally case isolated 19 12, ,01 0,03 Types 6021A..., 6023A... and 6025 A Type 6025 Available Configurations The Kistler sensor platform is highly flexible. s are available in different cable lengths and with several cable terminations. Options Length of hardline cable Various cable terminations Ex-Certification (Ex-nA, Ex-ia) IECEx ä1258 IECEx SEV XXXXX Ex na IIC T6 to T710 Gc Ex ia IIC T6 to T710 Gc SEV XX ATEX XXXX II 3G Ex na IIC T6 to T710 Ga II 1/2G Ex ia IIC T6 to T710 Ga 6021A pc/bar 9,5 Type 6021 Lemo PCA.0S _A_B0A A pc/bar 12 Type /16"-27 UNS-2A 602_A_B0B A pc/bar 12,7 Type
4 Two-Wire Softline Cables. Kistler's two-wire softline cables form an integral part of the differential measuring system. They are responsible for disturbance-free transmission of low level charge signals over distances up to 50 meters even in environments with electromagnetic interferences. Key Features Operating temperature range C / F 2-core twisted pair, indiv. braided shield Steel overbraid Locking connectors + + SGND Options Standard cable length: 5, 10 and 20 m Different connector options GND GND Available Cable Configurations Compatibility L = 0, m m Compatibility Type 602xAxA... A2 9,9 LEMO FFA.0S.302 FFA.1E A4 AI Casing Type 518xAA 46,3 5,3 41,3 Type Z20167 B2 12 Fischer S 103 A051 45,3 FGG.0B ,6 9,5 A2 e.g. Bently Electronics Type 602xAxB... C2 13 7/16"-27 UNS-2A 31, , pole open leads plus drain wire A3 DIN Rail Casing Type 517xAB Cable gland for AI Casing Type 518xAA 4
5 Differential Charge Amplifiers. Kistler's differential charge amplifier family offers a wide range of signal conversion possibilities and is available in non-ex, Ex-ia and Ex-nA versions. Type Version Ex Protection Enclosure 5181A... Non-Ex version 5183A... Ex-ia II 3G Ex na II T5 Ga II 3G Ex na IIC T5 Ga X 5185A... Ex-nA II 3G Ex na IIC T5 Gc II 3G Ex na IIC T5 Gc X Each Type is available in two enclosure versions Aluminum die cast enclosure Ideal for low channel count Installation in Ex-zone without additional enclosure Connectors or cable glands Aluminum die-cast Plastic DIN-Rail Aluminum die-cast Plastic DIN-Rail Signal Output and Power Supply Option only for Type 5181A available Types 5181AA... / 5183AA... / 5185AA... Plastic DIN-Rail enclosure Ideal for high channel count Installation in Ex-zone requires additional "Ex Box" Screw terminal connections 114,5 99 Types 5181AB... / 5183AB... / 5185AB... 22,5 Options Sensitivity: Default U-Out version: 10 mv/pc I-Out version: 6 μa/pc Custom SE voltage Out * ±10 V: mv/pc SE voltage Out 5 ±5 V: mv/pc Diff. Out ±10 V: mv/pc I-Out 14 ±6 ma: μa/pc * Extended ranges are available on request Signal output options: Voltage SE (±10 V; 5 ±5 V) or Differential (±10 V) Current (14 ±6 ma); 3-wire or 2-wire current loop Programmable low and high pass filter Default (f HP 0,5 Hz / f LP 10 khz) 5
6 Measuring Chain Configurations. The following examples show some of the most common measuring chain configurations for non-ex and for Ex-protection Ex-nA and Ex-ia. HT-Pressure s Softline Cable Differential Charge Amplifier Typ 5181AA... Non-Ex Installation Type 6021A-... Typ 6023A-... Typ 6025A-... Softline cable Typ 5181AB... Typ 5185AA... Ex-nA (Zone 2) Installation Type 6021AE... Typ 6023AE... Typ 6025AE... Softline cable Typ 5185AB... HT-Pressure s Softline Cable Differential Charge Amplifier Ex-barrier Typ 5183AA... Ex-ia (Zone 0, 1, 2) Installation Type 6021AE... Typ 6023AE... Typ 6025AE... Softline cable Typ 5183AB... 3rd party 6
7 Special Use Cases. The following use cases show how Kistler measuring chains can be configured to meet specific requirements. Use Case 1: Ex-Applications (-na, -ia) 1-wire PE Differential Charge Amplifier For applications in hazardous environment (-na, -ia) standard 1-wire PE Ex-certified pressure sensors can be operated with the differential charge amplifier Type 5183 or Hazardous area (ATEX Zone 2) Non-hazardous area p 1-Wire PE Softline Cable Differential Charge Amplifier Type 5185A... Advantage: Ex-applications can be covered available on request DA System Disadvantage: non differential signal Use Case 2: Differential Single Ended Operation of differential output sensor with a conventional non-differential charge amplifier (typically in a laboratory environment). p Type 6021A..., 6023A..., 6025A... Softline Cable Type 1654A... Non-differential Charge Amplifier DA System Advantage: use of non-differential charge amplifiers Disadvantage: non differential signal 1-wire Ground Isolated Connecting Cable, Type 1654A... For operation with non-differential charge amplifiers. LEMO FFA.0S pole connector BNC pos. 7/16"-27 UNS-2A 7
8 e , Kistler Group Kistler Group Eulachstrasse Winterthur Switzerland Tel Kistler Group includes the Kistler Holding AG and all its subsidiaries in Europe, Asia, Americas and Australia. Find your local contact at
I Ex-protected connectors exlink I
Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationPMG. Vibration Energy Harvesters
FEATURES Designed to power high performance Wireless Sensor Nodes. High power output up to 27.5mW High reliability design, including hermetically-sealed stainless steel case. Intrinsically Safe for use
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationCapacitance Level Measurement Electronic insert FEC 12
Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical
More informationModel JDF Field Indicator
Data Sheet DS/JDF-EN Rev. F Model JDF Field Indicator Engineered solutions for all applications Measurement made easy Digital LCD provides reliable and clear indications Flexible configuration facilities
More informationPendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSentronic PLUS Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications
More informationATEX-manual for units
ATEX-manual for units LMK70-ATEX (Zone 0) LMK70-ATEX (Zone 0/20) ATEX-Barrier Generic installation directive according to EN60079-14 (Gas) EN60079-17 (Maintenance Gas) Since LMK70-ATEX is intrinsically
More informationEddy Current Probe System
CMSS 785 Eddy Current Probe System API-670 Proximity transducer system, 5 mm and 8 mm Eddy Current Probe System The CMSS 785 system is an eddy current type non-contact displacement/ vibration system, used
More informationassociates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix
associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix Contents 1. Introduction 2. Selecting a model 2.1 Mounting 2.1.1 Field mounting 2.1.2
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More information3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications
. Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending)
More informationIEPE Premium Accelerometer, Top Connector
IEPE Premium Accelerometer, Top Connector Main Characteristics Atex Approved for zone 0, 1, 2. Annular shear mode (better than obsolete compression design) 10, 50, 100, 250, 500, 1000 mv/g version available
More informationIEPE Premium Accelerometer, Side Connector
IEPE Premium Accelerometer, Side Connector Main Characteristics Atex Approved for zone 0, 1, 2. Piezoelectric annular shear mode 10, 50, 100, 250, 500, 1000 mv/g version available -55 C to 120 C (-67 F
More informationPACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB
September 2013 PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB The PACSystems * Thermocouple Input module IC695ALG412 provides twelve isolated differential thermocouple input channels.
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationMaterial: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More information7 Lighting Technology
7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection
More informationEx td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread
I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem
More informationDMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A
More informationRMA42. Technical Information
Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and
More informationRIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values
Technical Information RIA45 Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values Application Plant and apparatus engineering and construction Control
More informationMaterial: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationSentronic PLUS. Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage
More informationSITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43
Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.
More informationACT20X Series for hazardous area applications Section A
ACT20X Series for hazardous area applications Section A Weidmüller has specifically designed the ACT20X line for process automation applications in Ex and non-ex zones. The 17 different variants can process
More informationI/A Series Hardware Fieldbus Communications Module, FCM10Ef
Product Specifications I/A Series Hardware ieldbus Communications odule, C10Ef The C10Ef ieldbus Communications odule is a fiber optic communications interface which allows the DIN rail mounted ieldbus
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationCAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry
CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001
More informationDS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0
More informationLVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:
HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement
More informationMB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN
Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically
More informationLevel Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB
Level Switch LS Ex KS Ex RS Ex Manual Level Switch Ex Manual version 3.0 March 2013 2 1. Table of contents 1. Table of contents...3 2. Manufacturer information...4 Manufacturer Declaration of Conformity...4
More informationDMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.
DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output
More informationRIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values
Technical Information RIA46 Field meter Digital field meter with control unit for monitoring and visualizing analog measured values Application Process recording and supervision Process control Signal
More informationIECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2
IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2 10. Cable entry systems and blanking elements 10.2 Selection of cable
More informationLMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor
LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar
More informationPROPORTIONAL VALVES Sentronic plus
04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital
More informationPACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB
September 2013 PACSystems* RX3i Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB Isolated +24 VDC Power Isolated Thermocouple
More informationBNC-2110 DESKTOP AND DIN RAIL-MOUNTABLE BNC ADAPTER
INSTALLATION GUIDE BNC-2110 DESKTOP AND DIN RAIL-MOUNTABLE BNC ADAPTER Introduction This installation guide describes how to install and configure your BNC-2110 accessory with an E Series or waveform generation
More informationGuide for installers. METTLER TOLEDO MultiRange System solution Point Ex.
Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the
More informationMODEL HS35 DRAWWORKS OPTICAL ENCODER
MODEL HS35 DRAWWORKS OPTICAL ENCODER Product Description This specially configured DrawWorks Model HS35 encoder combines rugged, heavy-duty features into a unique through-shaft style for use as a winchturns
More informationPressure transmitter For applications in hazardous areas Model IS-3
Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine
More informationRSCC. Load cells. Special features. Data sheet
RSCC Load cells Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions, test
More informationEXPlora. Introduction
Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant
More information- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request
DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.
More informationDMP 331i / DMP 333i LMP 331 i
DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma
More information3500/42M Proximitor*/Seismic Monitor
3500/42M Proximitor*/Seismic Monitor Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/42M Proximitor*/Seismic Monitor is a four-channel monitor that accepts input from proximity
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and
More informationIndustriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500
Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B
More informationPSI-MOS-RS232/FO 850 E Serial to Fiber Converter
PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to
More informationMID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J
MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance
More informationCircuit-Breakers for Motor Protection Series 8523/8
> Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting
More informationQuality products from a single source
Velocity sensors Quality products from a single source For more than 50 years Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full
More information3 Cleaning. 4 Technical data
EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution
More informationSAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations
LED Class I, Division 2, Groups A, B, C, & D Class II, Divisions 1 & 2, Groups E, F & G Class III UL 1598A Marine Outside Type UL 1598 Wet Locations UL 844 Hazardous Locations UL 8750 LED Safety Tested
More informationBNC-2120 INSTALLATION GUIDE. Connector Accessory for Multifunction DAQ Devices
INSTALLATION GUIDE BNC-2120 Connector Accessory for Multifunction DAQ Devices This installation guide describes how to install, configure, and use your BNC-2120 accessory. If you have not already installed
More informationCapacitance Limit Detection nivotester FTC 420/421/422
Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit
More informationSignal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters
Signal Conditioners Highlights Battery powered Line powered Multi-purpose Modular-style Multi-channel Charge & impedance converters Industrial charge amplifiers & sensor simulators PCB Piezotronics, Inc.
More informationFIELD MOUNTED RATE TOTALISER MODEL 202D
FIELD MOUNTED RATE TOTALISER MODEL 202D 16 June 2003 Introduction 1 1. INTRODUCTION The Model 202Di Rate Totaliser is a microprocessor based instrument which accepts a frequency or pulse input from
More informationOperating instructions
108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.
More informationJUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat
More informationCATEGORY 6 CABLING SOLUTIONS
With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality
More informationHighlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors
Cables & Adaptors Highlights: Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Adaptors www.pcb.com 716-684-0001 PCB Piezotronics, Inc. Automotive Sensors Division Common
More informationSpeed sensor MiniCoder GEL 2471
Speed sensor MiniCoder GEL 2471 for electrically conducting toothed-wheels Technical information version 10.02 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless
More informationDS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO
Ceramic Sensor accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire:
More informationDS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection
with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges
More informationTFRH Hygienic RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy
More informationUser manual Version Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../...
User manual Version 3.00 Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../... User manual Remote station XGA 15'' family Remote station SXGA 18''
More informationRosemount 1151 Smart Pressure Transmitter
Rosemount 1151 Smart Pressure Transmitter Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Connect the Wiring and Power Up Step 4: Set Switches Step 5: Configuration Step 6:
More informationDMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationI/A Series Hardware Fiber Optic LAN Converter
I/A Series Hardware PSS 21H-7F3 B4 The provides bidirectional conversion between coaxial and fiber optic media. The converter is compatible with existing I/A Series system hardware, utilizes industry standard
More informationLevel Measurement silometer FMC 420, FMC 423
Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level
More information4 Wiring Brochure Wiring and installation of specific control
- Wiring Brochure tekmarnet 4 User Switch 480 W 480 09/09 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in
More informationInstruction Manual. Universal Flow Controller Model 261 / 261-EC-01
Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation
More informationExCam XPT Q6055. User Manual
ExCam XPT Q6055 User Manual Table of contents 1 Introduction... 4 2 Technical data... 5 2.1 Explosion protection... 5 2.2 Electrical parameters of the camera... 5 2.3 Connection cable Ex-d - Ex-e (ASKDP03-T)...
More information2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES
EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,
More informationGeneral Specifications
General Specifications EJA-E Series PROFIBUS PA Communication PROFIBUS is a vendor-independent and open fi eldbus based on the international standerd IEC61158 and IEC61784. It covers a wide range of applications
More informationPT9420 Cable Actuated Sensor Industrial ma 0..20mA
PT9 Cable ctuated Sensor Industrial.. m 0..m bsolute Linear Position to 550 inches ( meters) luminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 / NEM 6 Hazardous
More informationQuick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B
Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B (See Complete I&M Manual for Further Detail) LOOK FOR THIS AGENCY MARK ON OUR PRODUCTS
More informationPT8420 Cable Actuated Sensor Industrial ma 0..20mA
PT8 Cable ctuated Sensor Industrial.. m..m bsolute Linear Position to 6 inches (5 mm) luminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 / NEM 6 Hazardous rea Certification
More informationSTBART0200K standard analog input kit STB - 2 I - 15 bits + sign
Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number
More informationFlow Measurement SITRANS F M
Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate
More information