G P DIMENSIONAL DATA. Specifications Included in this Booklet:

Size: px
Start display at page:

Download "G P DIMENSIONAL DATA. Specifications Included in this Booklet:"

Transcription

1 DIMENSIONAL DATA G P Specifications Included in this Booklet: Solvent Weld Schedule 0 DWV Fittings Gasketed Schedule 0 DWV Fittings K 101 3rd ST. NW Fargo, North Dakota 52 Phone: Toll Free: Fax: or

2 TABLE OF CONTENTS PAGE NUMBER " - 2" SOLVENT WELD SCHEDULE 0 DWV FITTINGS Saddles - Solvent Skirt, Solvent Branch 3 Tees - HxHxH Tees - SXHXH Couplings Wyes - HxHxH - 5 Wyes - SXHXH 5 Concentric Reducers - Couplings and Bushings 5 - Eccentric Reducers - Couplings and Bushings - 7 Caps 7 Plugs Sp 7 T-Y's - HxHxH 7 - T-Y'S - SXHXH Double Wyes Crosses - 9 Elbows /, 22 1/2, 30, 5 and 90; HxH and SxH 9 - Threaded Adapters and Plugs IPS x Sewer Adapters 11 Countersunk Threaded Plugs 11 Combo T-Y HxHxH 11 Test Tees - HxHxFIPT with Plugs Two-Way Cleanout Downspout Adapters " - " GASKETED SCHEDULE 0 DWV FITTINGS Saddles - Solvent Skirt, Gasket Branch 13 Tees - GxGxG 13 Couplings - Stop and Repair 13 Wyes - GxGxG 13 Concentric Reducers - Couplings and Bushings 13 Eccentric Reducers - Couplings and Bushings 1 Caps 1 Plugs 1 T-Y's - GxGxG 1 Double Wyes 1 Crosses 1 Manhole Adapters 1 Elbows /, 22 1/2, 30, 5 and 90; GxG and SxG 15 IPS x Sewer Adapters 1 Combo T-Y GxGxG 1 Deep Socket Fittings 1 SCHEDULE 0 DIMENSIONS 17 IPS WALL THICKNESSES 1

3 3 3 *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only " - 2" SOLVENT WELD SCHEDULE 0 DWV FITTINGS x x x x x x x x x x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x1 1x 1x 1x 1x 1x 1x1 1x1 x x x x x x1 x1 x1 2x 2x 2x 2x 2x 2x1 2x1 2x1 2x x x x x x x x x x x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x1 1x 1x 1x 1x 1x 1x1 1x1 x x x x x x1 x1 x1 2x 2x 2x 2x 2x 2x1 2x1 2x1 2x (H) FABRICATED SADDLE TEE SOLVENT BRANCH, SOLVENT SKIRT WITH STRAPS FABRICATED SADDLE WYE SOLVENT BRANCH, SOLVENT SKIRT WITH STRAPS

4 3 Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 0 0 " - 2" SOLVENT WELD SCHEDULE 0 DWV FITTINGS x* x* x* x* x* x* x x x x x x x x x 1x 1x 1x 1x 1x 1x1 1x 1x 1x 1x 1x 1x1 1x1 1x 1x 1x 1x 1x 1x1 1x1 1x1 x x x x x x1 x1 x1 x 2x x 2x 2x 2x 2x1 2x1 2x1 2x 2x2 * * * * x* x* x* x* x* x* x* x* x x x x x x x 1x 1x (C) (H) (D) (C) (H) (D) (C) (H) 2.50 (N) (E).5 (P) TEE HxHxH TEE HxHxH STOP COUPLING HxH WYE HxHxH TEE SXHXH

5 5 3 *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only x 1x 1x 1x1 1x 1x 1x 1x 1x 1x1 1x1 1x 1x 1x 1x 1x 1x1 1x1 1x1 x x x x x x1 x1 x1 x 2x 2x 2x 2x 2x 2x1 2x1 2x1 2x 2x2 * (M) (P) (SD1) (R) x* x x x x1 x1 x1 x x2 x x x x1 x1 x1 x x2 x x x1 x1 x1 x x2 x x1 x1 x1 x x2 x1 x1 x1 x x2 1x1 1x1 1x 1x2 1x1 1x 1x2 1x 1x2 x2 WYE HxHxH REDUCER COUPLING HxH " - 2" SOLVENT WELD SCHEDULE 0 DWV FITTINGS WYE SXHXH

6 3 Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 0 0 x x x x x x x x x x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x1 1x 1x 1x 1x 1x 1x1 1x1 x x x x x x1 x1 x1 2x 2x 2x 2x 2x 2x1 2x1 2x1 2x x x x x x1 x1 x1 x x2 x x x x1 x1 x1 x x2 x x x1 x1 x1 x x2 x x1 x1 x1 x x2 x1 x1 x1 x x2 1x1 1x1 1x 1x2 1x1 1x 1x2 1x 1x2 x ECC ECC 309-0ECC 309-0ECC ECC ECC ECC 309-0ECC ECC ECC 309-0ECC 309-0ECC ECC ECC ECC 309-0ECC ECC 309-0ECC 309-0ECC ECC ECC ECC 309-0ECC ECC 309-ECC 309-1ECC 309-1ECC 309-1ECC 309-ECC 309-2ECC 3091ECC 309-1ECC 309-1ECC 309-ECC 309-2ECC ECC ECC 309-1ECC ECC ECC 309-1ECC ECC 309-1ECC ECC 309-2ECC (R) (S) " - 2" SOLVENT WELD SCHEDULE 0 DWV FITTINGS REDUCER BUSHING SxH ECCENTRIC REDUCER COUPLING HxH (SD1) (R)

7 7 3 *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 0 0 x x x x x x x x x x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x1 1x 1x 1x 1x 1x 1x1 1x1 x x x x x x1 x1 x1 2x 2x 2x 2x 2x 2x1 2x1 2x1 2x * * * * * * * x* x* x* x x x x x x x x x 1x 1x 1x 1x 1x 1x 1x 1x 1x x x 3-00ECC 3-00ECC 3-00ECC 3-0ECC 3-0ECC 3-0ECC 3-0ECC 3-0ECC 3-0ECC 3-ECC 3-01ECC 3-01ECC 3-01ECC 3-1ECC 3-1ECC 3-01ECC 3-01ECC 3-01ECC 3-1ECC 3-1ECC 3-11ECC 3-01ECC 3-01ECC 3-01ECC 3-1ECC 3-1ECC 3-11ECC 3-11ECC 3-0ECC 3-0ECC 3-0ECC 3-ECC 3-ECC 3-1ECC 3-1ECC 3-1ECC 3-02ECC 3-02ECC 3-02ECC 3-2ECC 3-2ECC 3-21ECC 3-21ECC 3-21ECC 3-2ECC (S) " - 2" SOLVENT WELD SCHEDULE 0 DWV FITTINGS T-Y HxHxH PLUG SP CAP H ECCENTRIC REDUCER BUSHING SxH (F) (R) (S)

8 3 Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED (C) (H) (D) x 2x 2x 2x * x* x x x x x x x x x x x x x 1x 1x 1x 1x 1x 1x1 1x 1x 1x 1x 1x 1x1 1x1 1x 1x 1x 1x 1x 1x1 1x1 1x1 x x x x x x1 x1 x1 x 2x 2x 2x 2x 2x 2x1 2x1 2x1 2x 2x2 x x x x x x x x x x x x x x 1x 1x 1x 1x 1x 1x1 1x 1x " - 2" SOLVENT WELD SCHEDULE 0 DWV FITTINGS T-Y SXHXH T-Y HxHxH DOUBLE WYE HxHxHxH DOUBLE WYE HxHxHxH CROSS HxHxHxH

9 " - 2" SOLVENT WELD SCHEDULE 0 DWV FITTINGS Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 0 (C) (H) (D) 0 1x x x x x x x x 1x 1x / DEGREE EL SxH x x * x * x * x x x x x /2 DEGREE EL x HxH CROSS HxHxHxH x1 x 2x 2x 2x 2x * * * x x x1 2x1 2x /2 DEGREE EL SxH x (A) / DEGREE EL HxH DEGREE EL HxH *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 3 9

10 Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 0 (A) 0 (D) (E) * * * * DEGREE EL SxH DEGREE EL SxH (A) Give GPK's Customer Service Department a call for * DEGREE the specifications you need for these elbows. Call * FABRICATED us TOLL FREE at * BENDS * HxH and SxH Give size and angle of elbow needed for proper specifications Give GPK's Customer Service Department a call DEGREE for the specifications you need for these elbows. 5 DEGREE EL FABRICATED Call us TOLL FREE at HxH BENDS HxH and SxH Give size and angle of elbow needed for proper (A) specifications. * (L2) * * * * * FIPT x SCH HUB ADAPTER (S) 5 DEGREE EL * SxH * * (G) RAISED MIPT * PLUG * (L2) * * * DEGREE EL HxH FIPT X SCH 0 SPIGOT ADAPTER *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 3

11 Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 0 (S) 0 * x* * x x IPS HUB x SEWER SPIGOT ADAPTER x* x x x (S) x * x * x x IPS SPIGOT x SEWER HUB ADAPTER x x 1x (N) (D) (C) 1x * x * x x x IPS HUB x SEWER x HUB ADAPTER 3x* x x x (S) x * x * x COUNTERSUNK MIPT PLUG COMBO WYE HXHXH 2x 2x 2x *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 3 11

12 Molded fittings are manufactured to the dimensions of ASTM D25. Fabricated fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 0 (A) (B) (C) 0 x x x x x x x x x x x x x x x TEST TEE 1x HxHxFIPT 1x WITH PLUG 1x (C) (H) (D) x* x* TWO WAY CLEANOUT (SD1) (N) 2x3x* xx* xx* STANDARD DOWNSPOUT (CENTERED) *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 3

13 13 3 *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. Fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 0 0 FABRICATED SADDLE WYE GASKET BRANCH, SOLVENT SKIRT WITH STRAPS FABRICATED SADDLE TEE GASKET BRANCH, SOLVENT SKIRT WITH STRAPS TEE GxGxG STOP COUPLING GxG REPAIR COUPLING GxG WYE GxGxG REDUCER COUPLING GxG REDUCER BUSHING SxG " - " GASKETED SCHEDULE 0 DWV FITTINGS x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x (C) (P) (R) (R) (H) (H) (N) (S) (D) (SD1) x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x G G G G301-0 G301-0 G301-0 G301-0 G301-0 G301-0 G301- G G G G302-0 G302-0 G302-0 G302-0 G302-0 G302-0 G302- G G G G G G303-0 G303-0 G303-0 G303- G303-0 G303-0 G303-0 G303- G303- G G G G G G G G G30-00 G30-00 G G G G G G307-0 G307-0 G307-0 G307- G307-0 G307-0 G307-0 G307- G307- G G G309-0 G309-0 G G309-0 G309-0 G309-0 G309-0 G309- G3-00 G3-00 G3-00 G3-0 G3-0 G3-0 G3-0 G3-0 G3-0 G3-

14 3 Fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 1 *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 0 0 x x x x x x x x x x X X X X X X X X X X * * x x x x x x x x x x x x* x x x x x x x x x x x x x x x x x x x x x x x x x x x (R) (C) (S) (F) (S) (H) (D) " - " GASKETED SCHEDULE 0 DWV FITTINGS G309-00ECC G309-00ECC G309-0ECC G309-0ECC G309-00ECC G309-0ECC G309-0ECC G309-0ECC G309-0ECC G309-ECC G3-00ECC G3-00ECC G3-0ECC G3-0ECC G3-00ECC G3-0ECC G3-0ECC G3-0ECC G3-0ECC G3-ECC G G G G G G G G G G G313-0 G313-0 G313-0 G313-0 G313-0 G313-0 G G G G G G315-0 G315-0 G315-0 G315- G315-0 G315-0 G315-0 G315- G315- G32-00 G32-00 G32-00 G32-00 G32-00 G32-0 G32-0 G32-0 G32- G32-0 G32-0 G32-0 G32- G32- G G G G31-00 G CROSS GxGxGxG PLUG SP T-Y GxGxG DOUBLE WYE GxGxGxG MANHOLE ADAPTER CAP G ECCENTRIC REDUCER COUPLING GxG ECCENTRIC REDUCER BUSHING SxG (R) (SD1)

15 " - " GASKETED SCHEDULE 0 DWV FITTINGS Fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 0 0 (A) G G G G G G G G / DEGREE EL G DEGREE EL G GxG SxG (A) G G G G G G G G / DEGREE EL SxG G DEGREE EL GxG G (A) G G G G G G G G /2 DEGREE EL GxG G DEGREE EL SxG G (G) G G G G G G /2 DEGREE EL G31-00 G DEGREE EL GxG G G SxG (A) (D) (E) G G G G G G DEGREE EL G31-00 G DEGREE EL SxG G32-00 G GxG *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 3 15

16 Fittings are manufactured to ASTM F1 specifications. To be used for non-pressure drainage applications only. 0 0 x G DEGREE FABRICATED BENDS GxG and SxG Give GPK's Customer Service Department a call for the specifications you need for these elbows. Call us TOLL FREE at Give size and angle of elbow needed for proper specifications. x x x x x x x G3-00 G3-00 G3-00 G3-00 G3-0 G3-0 G x G DEGREE FABRICATED BENDS GxG and SxG Give GPK's Customer Service Department a call for the specifications you need for these elbows. Call us TOLL FREE at Give size and angle of elbow needed for proper specifications. COMBO WYE GXGXG x x G3-0 G3-0 G317-0DS G317-0DS (A) G G (S).25 DEEP SOCKET 22 1/2 EL GxDSG G (A) G G351-0DS IPS G x SEWER SPIGOT ADAPTER G G351-0DS (S) G G G DEEP SOCKET 5 EL GxDSG G (SD1) SEWER G x IPS SPIGOT ADAPTER G G305-0DS G305-0DS (SD1) G G G G DEEP SOCKET SETTLER COUPLING GxDSG IPS G x SEWER G ADAPTER G G325-0DS (S).25 G325-0DS DEEP SOCKET SETTLER COUPLING SPxDSG 1 *DENOTES MOLDED FITTING. ALL OTHERS ARE FABRICATED. 3

17 SCHEDULE 0 DIMENSIONS SCH. 0 SOLVENT WELD SCH. 0 GASKETED SCH. 0 PIPE SIZE SD OD SD OD C OD " Fabricated " Molded " Fabricated " Molded " Fabricated " Molded " Fabricated " Fabricated " Fabricated " Fabricated " Fabricated " Fabricated " Fabricated 1 2 SOLVENT SOCKET GASKETED SOCKET OD SD C SD OD 17

18 IPS WALL THICKNESSES SIZE SCH 0 SCH 0 SCH 0 SDR CLASS 3 CLASS 0 SDR 1 CLASS 5 SDR 32.5 CLASS 10 SDR 2 CLASS 0 SDR 21 CLASS 250 SDR 17 CLASS 315 SDR 13.5 " " " " " 1" 1" 1" " 2"

19

20 IF YOU NEED IT, WE HAVE IT -- OR WE'LL MAKE IT FOR YOU! We are in business to take care of you, OUR CUSTOMERS! PHONE: FAX:

Nominal Feet Feet List Price Pipe Item # I.D. x Length O.D. Per Bag Per Crate Per 100 Feet

Nominal Feet Feet List Price Pipe Item # I.D. x Length O.D. Per Bag Per Crate Per 100 Feet Page 1, May 2006 CPVC Copper Tube Size Pipe & Fittings CPVC Copper Tube Size Pipe Tubing for use with CPVC CTS fittings for hot or cold water applications. Complies with ASTM D2846. Working pressure: 100

More information

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates Flexible Couplings Transitions all types of DWV plastic, copper, steel, cast iron and clay pipe. 300 series stainless steel clamps Flexibility - Sleeve is manufactured of molded natural and synthetic rubber

More information

,

, Page 39 Description Part Number List Price Section Three NuFlex Tubing Siphon Tubes Sprinkler Mainline Tubing Gated Accessories Vacuum PVC Underground Gates & Accessories 40 40 42, 46 43 4445 46 47 4849

More information

Schumacher Irrigation, Inc. Phone: or Fax:

Schumacher Irrigation, Inc. Phone: or Fax: Page 38 Nu-Flex Tubing & Siphon Tubes Oetiker Clamp (Single Ear) -Oetiker ear type clamps "Breathe" and adapt to the expansion and contraction of hose affected by thermodynamics or aging, no need to retighten

More information

FLOWGUARD GOLD PIPE & FITTINGS CPVC SPECIALTY FITTINGS

FLOWGUARD GOLD PIPE & FITTINGS CPVC SPECIALTY FITTINGS FLOWGUARD GOLD PIPE & FITTINGS CPVC SPECIALTY FITTINGS FLOWGUARD GOLD PIPE & FITTINGS FGG-0513 MAY 2013 SUPERCEDES FGG-0612R CPVC SPECIALTY FITTINGS SP-0512R MAY 21, 2012 SUPERCEDES SP-0311 CPVC PIPE CPVC

More information

EverTUFF TURF FITTINGS

EverTUFF TURF FITTINGS EverTUFF TURF FITTIGS TECICA IFORATIO WEIGTS & DIESIOS Visit our web site www.spearsmfg.com 897 Fittings Engineered for Golf Course & Turf Applications Independent Testing Proves EverTUFF TURF 2X Stronger

More information

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

COPPER FITTINGS COPPER FITTINGS. REPAIR COUPLING Slides over broken pipe to repair leak. COUPLING Sweat x Sweat

COPPER FITTINGS COPPER FITTINGS. REPAIR COUPLING Slides over broken pipe to repair leak. COUPLING Sweat x Sweat Sweat Sweat Red. No - Stop Repair Fitting Reducer Reducing Female Reducing Fe. COUPLING Sweat x Sweat 1/8" 18-0500 100 1/8" Carded 18-0501 6 1/4" 18-0510 50 1/4" Carded 18-0511 6 3/8" 18-0520 25 3/8" Carded

More information

Potable and Hydronic Pex System PEX-0315 MARCH 2015 SUPERSEDES PEX-0214

Potable and Hydronic Pex System PEX-0315 MARCH 2015 SUPERSEDES PEX-0214 Potable and Hydronic Pex System PEX-0315 MARCH 2015 SUPERSEDES PEX-0214 TABLE OF CONTENTS PAGE MULTIPLIER CATEGORY MULTIPLIER PEX pipe SUPERPEX ultra resistant potable water pipe 3 C-54 OXYPEX oxygen barrier

More information

Water Rotary Unions. 100th. Special Design Features BARCO

Water Rotary Unions. 100th. Special Design Features BARCO BARCO BULLETIN RS 3100 BARCO SERIES E-75 RS Water Rotary s BARCO 1908 2008 100th ANNIVERSARY CARY, IL Special Design Features Dry run capability. Silicon carbide to carbon graphite mechanical seals. For

More information

DESIGN CONSULTING ENGINEERS Engineers, Geotechnical, Environmental & Material Scientists

DESIGN CONSULTING ENGINEERS Engineers, Geotechnical, Environmental & Material Scientists DESIGN CONSULTING ENGINEERS December 12, 2013 Mr. Mark Kozlowski, P.E. Design Manager Chicago Public Schools Capital Improvement Program 125 S. Clark St. ; 17 th Floor Chicago IL, 60603-5322 RE: Ravenswood

More information

Mechanical flow switch for On/Off control

Mechanical flow switch for On/Off control Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...

More information

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS DATA SHEET MS 3780 INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 OPTIONAL FEATURES 2 TECHNICAL DATA 2 OVERALL DIMENSIONS 3 LAYOUT 4 INSTALLATION 5 INSTALLATION RECOMMENDATIONS 6 SENSOR GROUNDING 7 SENSOR

More information

Formulate Designer Series 30 Backwall - Kit 05

Formulate Designer Series 30 Backwall - Kit 05 Formulate Designer Series 30 Backwall - Kit 05 FMLT-DS-30-05 Formulate TM Designer Series 30ft displays have unique stylistic features and shapes, are portable and easy to assemble. The aluminum tube frame

More information

O NEof Premium tools for professionals!

O NEof Premium tools for professionals! O NEof 6.000 Premium tools for professionals! 260 ROWELD Plastic Pipe Welding System Overview Plastic Pipe Welding 262-263 Cutting Cutting-/ Chamfering Tools 264-265 Orbital Circular Saw / Pipe Cutter

More information

Description of Bolt Torque Tables

Description of Bolt Torque Tables Maximum (preferred) torque required per bolt (foot pounds) to arrive at the maximum available / recommended gasket stress shown in the previous column. (4) Maximum gasket stress recommended or available

More information

Unmatched Product Range Material Availability Manufacturing Capabilities Innovative Applications and Engineering Expertise

Unmatched Product Range Material Availability Manufacturing Capabilities Innovative Applications and Engineering Expertise Unmatched Product Range Material Availability Manufacturing Capabilities Innovative Applications and Engineering Expertise Your True Project Partner Conversion Table... 2 Steel Sheet Pile... 3 5 7 9 11

More information

Page Number Official Detail Name Contact Title Primary Contact E mail Secondary Contact E mail

Page Number Official Detail Name Contact Title Primary Contact E mail Secondary Contact E mail MANHOLE SPECIFIC STR 11 1 Control Manhole Metered Program Manager Anne.Marie.Smrchek@cityoffortwayne.org Kristen.Buell@cityoffortwayne.org STR 11 2 Control Manhole Non Metered Program Manager Anne.Marie.Smrchek@cityoffortwayne.org

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

Unipole and Multipole Connectors

Unipole and Multipole Connectors Unipole and Multipole Connectors Miniature Cylindrical Connectors With Push-Pull-Locking Shenzhen Medplus Connector Co.,Limited. 2 th Floor,Ming An Street,GongMing Town, Baoan District, Shenzhen, China

More information

3M Fiber Closures BPEO

3M Fiber Closures BPEO 3M Fiber Closures BPEO 2 3M Fiber Closures BPEO The 3M Fiber Closures BPEO are designed with flexibility in application in mind. With a range of sizes, they can be deployed above grade (pole, facade) or

More information

The innovative ROWELD product programme offers tailor-made and economic customer solutions

The innovative ROWELD product programme offers tailor-made and economic customer solutions i The innovative ROWELD product programme offers tailor-made and economic customer solutions 240 ROWELD Plastic Pipe Welding Cutting Cutting / Chamfering Tool 242-243 Orbital Circular Saw / Pipe Cutter

More information

CM MTC PARTS LIST

CM MTC PARTS LIST 8650 Enterprise Drive, Peosta IA 52068-0050 319-556-7484 / Fax 319-556-1235 CM-2400-0MTC PARTS LIST ENGINE OIL GRADE: ENGINE OIL CAPACITY: PUMP OIL: PUMP OIL CAPACITY: NOZZLE SIZE: 30W 21 oz. MI-T-M #AW-4085-0016

More information

Seaflex Beachflex. Joint Closures SEAFLEX BEACHFLEX JOINT CLOSURES

Seaflex Beachflex. Joint Closures SEAFLEX BEACHFLEX JOINT CLOSURES Seaflex Beachflex Joint Closures SEAFLEX BEACHFLEX JOINT CLOSURES 1 a complete solution is the Tykoflex submarine joint closure for fibre optic submarine cables. The closure is made of highly corrosion-resistant

More information

GS-HYDRO END FORMING MACHINES

GS-HYDRO END FORMING MACHINES GS-HYDRO END FORMING MACHINES Main index Reshaping machine... 4 Pre-assembly machines... 5 Deburring machines... 6 Tube cutting machines... 7 Cleaning system... 8 3 Reshaping machine M-WF 385Xplus Walform

More information

Selection matrix for electronic pressure switches

Selection matrix for electronic pressure switches Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film

More information

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved. Tab 10 - The NESC and Underground Applications Restricted Siemens Industry, Inc. 2017 All rights reserved. siemens.com/poweracademy The National Electric Safety Code (NESC) The NESC provides guidelines

More information

ECOQUIP 2 VAPOR ABRASIVE BLASTERS

ECOQUIP 2 VAPOR ABRASIVE BLASTERS ECOQUIP 2 VAPOR ABRASIVE BLASTERS PART NUMBERS AND SCHEMATICS GUIDE Company Profile Since 1944, Marco has developed a strong tradition of providing innovative and reliable products and services to the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS M9700 RGB SERIES Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes. Hydrel's M9700 Series of

More information

PEX-a Tube Now Available

PEX-a Tube Now Available PEX-a Tube Now Available Supply Drainage Support PowerPEX ASTM F1960 Grip CATEGORY ITEM NO. DESCRIPTION MIN. CAS Q TY. QTYẸ POWERPEX TUBE, STRAIGHT LENGTHS 664XA2N5 PEX Tube A 1/2" Natural 5' 20/Bag 1

More information

CM MVC & CM MHC PARTS LIST

CM MVC & CM MHC PARTS LIST 8650 Enterprise Drive, Peosta IA 52068 319-556-7484 / Fax 319-556-1235 CM-2400-0MVC & CM-2403-0MHC PARTS LIST (After Serial #215703) Vanguard Engine Oil Grade: Vanguard Engine Oil Capacity: Honda Engine

More information

PLASMA CUTTING PROCESS INSTALLATION Inverter technology

PLASMA CUTTING PROCESS INSTALLATION Inverter technology CHAPTER PLASMA cutting PLASMA CUTTING PROCESS INSTALLATION Inverter technology SHARP including integrated compressor with CCT 00 torch and wear parts page SHARP 0 with CCT 000 torch and wear parts page

More information

DIN Connectors DIN06 E-03

DIN Connectors DIN06 E-03 DIN Connectors DIN0 E-0 Contents Introduction HOSIDEN DIN connectors are supplied to electronic equipment manufacturers both in Japan and overseas and are very well accepted because of high quality, a

More information

VITALink Taped Splice Straight Through Crimp

VITALink Taped Splice Straight Through Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Straight Through Crimp 2 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink

More information

KEL 24 Cable entry frames

KEL 24 Cable entry frames 24 Cable entry frames Split inserts Description Type Order No. Inserts KT PU small large The 24 matches exactly the cut-out dimensions of 24-pole standard industrial connectors. 24 42241 - The split insert

More information

Check what you have received against the component checklist and hardware above.

Check what you have received against the component checklist and hardware above. SA46S SA46W SA46B SA46PB Component Checklist Installation Instructions SYSTEMA Systema Monitor Arm 460mm HARDWARE Display Mounting Spacers (x4) Display Mounting Screws Arm Assembly VESA monitor head M4

More information

KVT Split cable glands

KVT Split cable glands KVT Description Type Order Grommets Thread PU KVT is a circular split frame for quick and easy installation and sealing of cables with connectors or complete cable harnesses. 3 KVT 20** 34 24 M20. Polyamide

More information

16S151-16S181 16S221-16S251 Planetary Gear with HELICAL TEETH

16S151-16S181 16S221-16S251 Planetary Gear with HELICAL TEETH 400.195 ZF EcoSplit Models 16S151-16S181 16S221-16S251 Planetary Gear with HELICAL TEETH 04/2008 File ZFE0023.Pdf 1 Z.F. EcoSplit III 6S151 to 16S25 6S251 From 16S1 suitable to : Planetary Gear with HELICAL

More information

Grounding-type plugs and sockets K Product information

Grounding-type plugs and sockets K Product information Product information Plugs and sockets for harsh conditions. SCHUO by MENNEES with the hammer symbol. Acc. to VDE 0105 part 115. Made of high-grade AMAPLAST. Acc. to VDE 0620 for harsh conditions. Application

More information

Cables for robot applications

Cables for robot applications Cables for robot applications 67 Primary cables Robot primary cable Cable design Internal conductor Special conductor Strand class VI (super-fine wire) Highly flexible Core insulation TPM or PUR Core identification

More information

Stainless Steel SMA Connectors Product Catalog

Stainless Steel SMA Connectors Product Catalog Stainless Steel SMA Connectors Product Catalog Connectivity...for Stainless Steel SMA Connectors Connectivity...for Johnson Stainless Steel SMA Connectors meet or exceed the performance requirements of

More information

Texas Indicator & Micrometer Repair Service All Work Guaranteed Prompt Service

Texas Indicator & Micrometer Repair Service All Work Guaranteed Prompt Service Texas Indicator & Micrometer Repair Service All Work Guaranteed Prompt Service www.texasindicator.com Info@texasindicator.com Calibration Price List Instrument(s) listed will be in compliances with stated

More information

TECHNICAL GUIDE. TOUGH GUN ThruArm G1 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-12, 100iC-6L, 100iC-7L, 120iC, 120iC-10L, 120iC-12L

TECHNICAL GUIDE. TOUGH GUN ThruArm G1 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-12, 100iC-6L, 100iC-7L, 120iC, 120iC-10L, 120iC-12L TECHNICAL GUIDE TOUGH GUN ThruArm G1 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-12, 100iC-6L, 100iC-7L, 120iC, 120iC-10L, 120iC-12L INSTALLATION MAINTENANCE TECHNICAL DATA OPTIONS EXPLODED VIEW

More information

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits 3 Quante BPEO Splice-Protection Closure for Optical Fiber Cables BPEO: Fully Mechanical, Easy to Install, No Specific Tools BPEO is the newest generation of watertight spliceprotection closures for optical

More information

BORING INSTRUCTIONS. If part is being mounted to a structural tee, angle iron or steel plate, drill holes as indicated below: 3/8 (.

BORING INSTRUCTIONS. If part is being mounted to a structural tee, angle iron or steel plate, drill holes as indicated below: 3/8 (. BORING INSTRUCTIONS DJUST--BODY TENSIONER WITH THREDED BOLT Drill and tap holes as indicated below: DJUST--BODY TENSIONER WITH THREDED EYE If part is being mounted using an Invisiware Fixed Tab or Threaded

More information

Series SMPM-T. Description. Compatibility. Content. Interface dimensions (mm/inches) SMPM-T male (pin contact), smooth bore

Series SMPM-T. Description. Compatibility. Content. Interface dimensions (mm/inches) SMPM-T male (pin contact), smooth bore Series Description The is the smallest threaded open source connector on the market. Its unique and innovative combination of a MIL- STD-348 SMPM female interface connector together with a retractable

More information

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES 1.0 SCOPE TABLE OF CONTENTS 2.0 CABLES SPLICES 2.1 Definitions 2.2 Scope of Specifications and Drawings 2.3 General Requirements 2.4 Routing Cables 2.5 Connectors 2.6 Conductor Connections 2.7 Heat Shrinkable

More information

RetractaNet XS. Extractable Solutions for OSP. October 2012

RetractaNet XS. Extractable Solutions for OSP. October 2012 RetractaNet XS Extractable Solutions for OSP October 2012 OSP Solutions RetractaNet XS Solution Simple concept reduces the need for skilled labor for installation Easy direct buried deployment in soft

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION OCTALUMINA 120: PARTS LIST AND TECHNICAL INFORMATION HIGH POWER LEDS INNER CORNER LABELED FRAME MOUNTED POWER SUPPLY UNIT EASY PLUG-IN CONNECTION BRACING TECHNIQUE CABLE OUTLET AT THE BOTTOM SYSTEM PACKAGING

More information

StandardProducts DieCatalog

StandardProducts DieCatalog StandardProducts Catalog 3600U.S.Hwy52SouthLafayete,Indiana47905 Main:765-269-4360 Sales:855-604-3287 Email:sales@nanshanamerica-aat.com www.nanshanamerica-aat.com Welcome to Nanshan America's new and

More information

LUDLUM MODEL 43-5 ALPHA SCINTILLATOR. March 2011

LUDLUM MODEL 43-5 ALPHA SCINTILLATOR. March 2011 LUDLUM MODEL 43-5 ALPHA SCINTILLATOR LUDLUM MODEL 43-5 ALPHA SCINTILLATOR STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants the products covered in this manual to be free of defects due to workmanship,

More information

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T AIR BLOWN SYSTEM INTRODUCTION 2013 A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T O P T I R O A D INC. PRODUCT INFORMATION ABS FEATURES APPLICATION STRUCTURE & DIMENSION A IR B L O W

More information

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Models Hypra 16A References: see Annex 2

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Models Hypra 16A References: see Annex 2 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME CB TEST CERTIFICATE Product Plugs, socket-outlets and couplers for industrial purposes Name and address

More information

TruePlate Structural Plate

TruePlate Structural Plate TruePlate Structural Plate Galvanized Steel and Aluminum Alloy Sizes, Shapes and Height of Cover Tables TrueNorthSteel.com info@truenorthsteel.com 866-82-511 TruePlate Structural Plate Many drainage and

More information

Installation instructions Ex frames

Installation instructions Ex frames General information Installation and maintenance: For European member countries of GENELEC shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626) CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA 91746 (626) 330-3182 Fax (626) 330-9406 www.centralblower.com CATALOG REF - 01 JULY, 2001 Series RE Scoop with Grease Trough Sealed to blower

More information

SECTION Structured Cabling Systems

SECTION Structured Cabling Systems SECTION Structured Cabling Systems DuraPort Industrial Connectivity Products 1 Structured Cabling Systems DuraPort Products Listing DURAPORT INDUSTRIAL CONNECTIVITY oisture, dust, corrosion, acids, detergents,

More information

General Description. SC Configurations

General Description. SC Configurations S onnectors General Description Delta S series connectors are medium-size, 50Ω impedance connectors with 11 16-24 threaded coupling and good power handling capability, particularly those connectors noted

More information

Technical Service Bulletin

Technical Service Bulletin 1301 Stahley Drive Building #42 Nappanee, IN 46550 Newmar Corporation Warranty Department Technical Service Bulletin Date Issued Model Year(s) Affected TSB # 12/11/2015 2004-2007 437 Brand Bay Star Sport

More information

Air Moving Solutions. axifan TUBEaxial fans

Air Moving Solutions. axifan TUBEaxial fans Air Moving Solutions. axifan TUBEaxial fans MODEL TCTA CATALOG AX200 January 2013 TubeaxialFans Model TCTA 36 B 5 Model TCTA is available with UL/ CUL 705 listing for electrical, File No. E158680. Model

More information

STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES

STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE I. INSTALLATION INSTRUCTIONS I.1. PRECAUTIONS: I.1.1. Expansion bends must be made in the cables to allow for cable movement while

More information

The Custom Interconnect Leader TM

The Custom Interconnect Leader TM LC Series.5.188.685 ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage: Insulation Resistance: VSWR: 50 ohms DC to 1.0 GHz 5,000 volts rms 3,000 volts rms 5,000

More information

5374 Series Air Activated Tube Tester (For testing straight-through exchanger without removing both heads.)

5374 Series Air Activated Tube Tester (For testing straight-through exchanger without removing both heads.) TM-73 July 15, 2004 Elliott offers a complete line of precision tube tools, including: tube expanders Boiler Expanders Heat Exchanger Expanders Condenser Expanders Refinery Expanders tube rolling motors

More information

Genevac Accessories and Spares

Genevac Accessories and Spares Genevac Accessories and Spares For Rocket Synergy Evaporators Original instructions in English 04-8931 Issue 1-14 October 2015 Contents Introduction... 2 Maintenance of sample holders... 2 Limitations

More information

The Uniduct Nonmetallic Latching Raceway

The Uniduct Nonmetallic Latching Raceway Uniduct One-Piece Latching Raceway The Uniduct Nonmetallic Latching Raceway System is a one-piece single channel design, ideally suited to route and protect fiber optic, UTP, and and other low-voltage

More information

Product group 1. Product description. At a glance. Cable entry systems for entering pre-terminated cables

Product group 1. Product description. At a glance. Cable entry systems for entering pre-terminated cables Product group 1 Cable entry systems for entering pre-terminated cables At a glance The patented cable entry system enables the user to enter, seal and provide strain relief for pre-terminated and standard

More information

Signet 2250 Hydrostatic Level Sensor

Signet 2250 Hydrostatic Level Sensor Signet 2250 Hydrostatic Sensor *32250.090* 32250.090 Rev. A 10/06 English English Safety Instructions 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confi

More information

Mini Micro Pulse Lidar System

Mini Micro Pulse Lidar System Mini Micro Pulse Lidar System MiniMPL-532-C Sensor Suite Operations Manual Version: June 2016 THIS PAGE INTENTIONALLY LEFT BLANK 2 Table of Contents MINIMPL SENSOR SUITE SYSTEM: RECORD OF PURCHASE... 4

More information

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring

More information

QVP401 4x1 HDMI 2.0a Quad-View Video Processor

QVP401 4x1 HDMI 2.0a Quad-View Video Processor QVP401 4x1 HDMI 2.0a Quad-View Video Processor Contents 02 Warnings 03 Package Contents 04 Features 05 Specifications 06 Installation 07 Connection Diagram 08 Panel Description 01 Warnings The QVP401 4x1

More information

DLMP Installation Instructions

DLMP Installation Instructions DLMP Installation Instructions Tools Needed Posidrive No.3 Screwdriver Large Flat Head Screwdriver 2x 10mm Spanner 1x 13mm Spanner Ø8mm Drill Ø6mm Drill Kit Contents [ ] 1x Tube 2.5M long 17420 [ ] 2 x

More information

Wiring. Requirements

Wiring. Requirements Wiring Requirements to ensure that your new home s wiring and conduit infrastructure is correctly implemented to your home stays future proof, giving you access to future services without having to surface

More information

Revision 1.0 Parts List Minor

Revision 1.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded view...

More information

Revision 1.0 Parts List Salvador 1~, 3~

Revision 1.0 Parts List Salvador 1~, 3~ Revision.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded

More information

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable). Nuclear Sensors & Process Instrumentation Fiber Cable Basics Fiber-optic communication is a method of transmitting information from one place to another by sending light through an optical fiber. The light

More information

User Manual. Tensioned Screens. Website: Tel:

User Manual. Tensioned Screens. Website:    Tel: User Manual Tensioned Screens Website: www.luxburgvisual.com Email: support@luxburgvisual.com Tel: 0044 207 237 4842 Table of Contents SAFETY INFORMATION... 3 IMPORTANT SAFETY INSTRUCTION... 3 SETTING

More information

DLMP-45/45R Installation Instructions

DLMP-45/45R Installation Instructions DLMP-45/45R Installation Instructions Tools Needed Posidrive No.3 Screwdriver Large Flat Head Screwdriver 2x 10mm Spanner 1x 13mm Spanner Ø8mm Drill Ø6mm Drill Kit Contents [ ] 1x Tube 2.5M long 17420

More information

Pressure transmitter COMPACT IO-Link,

Pressure transmitter COMPACT IO-Link, Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic

More information

Revision 2.0 Parts List Minor

Revision 2.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3 Exploded

More information

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division SPECIFICATION FIBER OPTIC SPLICE CLOSURE Model Spec. No. Distribution Depts. VSOF-BS403A VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division Sales Division Management Division Revision 10. 07 (Rev.4)

More information

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0 x 22 8.5 x 22 (15.24 cm x cm cm x cm) OCTOBER 2004 COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x 55.88 cm 21.59 cm x 55.88 cm) Be sure to read and completely understand this procedure before applying

More information

Fiber Optic Splice Closure GPJ Instruction Manual

Fiber Optic Splice Closure GPJ Instruction Manual Fiber Optic Splice Closure GPJ09-9401 Instruction Manual 1. Brief Introduction GPJ09-9401 type of Fiber Optic Splice Closure is a member in dome series, the main function is to provice direct pass, branch

More information

Tools & Accessories JackEasy Termination Tool TAS. Tools & Accessories

Tools & Accessories JackEasy Termination Tool TAS. Tools & Accessories JackEasy Termination Tool TAS Anti-Slip Grip Sturdy Metal Body The JackEasy Tool Makes Terminating Faster & Easier! USE WITH ICC'S EZ AND HD MODULES! Features: Sturdy Metal Body - Manufactured with a steel

More information

Fiberglass - Technical Data

Fiberglass - Technical Data - Technical Data Cable Tray Thermal Contraction and Expansion X : Denotes hold-down clamp (anchor) at support. _ : Denotes expansion guide clamp at support. It is important that thermal contraction and

More information

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems April 02 Chore-Time Warranty Chore-Time Equipment, a division of CTB, Inc., ("Chore-Time")

More information

PEX TUBING POTABLE WATER OXYGEN BARRIER (RED) PRICING BY FOOT available upon request everflowsupplies.com

PEX TUBING POTABLE WATER OXYGEN BARRIER (RED) PRICING BY FOOT available upon request everflowsupplies.com PEX TUBING PIPING SYSTEM 1 POTABLE WATER All Tubing Conforms to ASTM F876, ASTM F877, CSA B137.5 Conforms to ASTM F2023, NSF 61, NSF-PW and NSF Protocol P171 PART # - RED PART # - BLUE PART# - WHITE DIAMETER

More information

3M Cold Shrink Splice Kit QS-III 5515A

3M Cold Shrink Splice Kit QS-III 5515A 3M Cold Shrink Splice Kit QS-III 5515A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric

More information

SR100,1x150W,HST,HITCE,ECG,TSG,dir,sd

SR100,1x150W,HST,HITCE,ECG,TSG,dir,sd Overview of product data: SR,1x15W,HST,HITCE,ECG,TSG,dir,sd 1/17 Product description 7 35 % HIT-CE E HST E SR, ast luinaire, priary light control with radial facetted optic, of aluiniu, facetted, priary

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION (FIBER OPTIC SPLICE CLOSURE) Model Spec. No. Distribution Depts. VSOF-BS403A SJP-0609-403A-01A/SD Quality Assurance Team Manufacturing Division Sales Division Management Division

More information

Installation instructions Roxtec RS ES Ex

Installation instructions Roxtec RS ES Ex General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) 2-3, Marunouchi 2-chome, Chiyoda-ku, Tokyo 100-8322, Japan No. FB-KL4001C for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) Aug 2014 1 1. General This specification describes

More information

2.4 METER SERIES 1250 ANTENNA SYSTEM

2.4 METER SERIES 1250 ANTENNA SYSTEM June 1,2009 Revision B Assembly Manual 2.4 METER SERIES 1250 ANTENNA SYSTEM General Dynamics SATCOM Technologies 1500 Prodelin Drive Newton NC 28658 2.4 Meter 2 Piece Az/El Installation Instructions B

More information

Beginning Band Supply List Bear Branch 6 th Grade Center All band students will need the following supplies:

Beginning Band Supply List Bear Branch 6 th Grade Center All band students will need the following supplies: FLUTE 2017-18 Beginning Band Supply List 1. Folding music stand for home practice 2. pencil needed for class every day 3. metronome/ tuner combo - TE Tuner app on i-pad or phone or a Korg TM-40 4. name/

More information

Industrial Loadbreak Elbow

Industrial Loadbreak Elbow Industrial Loadbreak Elbow 200 A 5, 8, and 15 kvclass 5810 Series Installation Instructions 1.0 General The 3M Industrial Loadbreak Elbow connector is a fullyshielded and insulated plug-in termination

More information

TECHNICAL GUIDE. TOUGH GUN ThruArm G2 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-6L, 120iC, 120iC-10L INSTALLATION MAINTENANCE

TECHNICAL GUIDE. TOUGH GUN ThruArm G2 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-6L, 120iC, 120iC-10L INSTALLATION MAINTENANCE TECHNICAL GUIDE TOUGH GUN ThruArm G2 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-6L, 120iC, 120iC-10L INSTALLATION MAINTENANCE TECHNICAL DATA OPTIONS EXPLODED VIEW & PARTS LIST ORDERING INFORMATION

More information

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink Splice Kit QS-III 5514A 3M Cold Shrink Splice Kit QS-III 5514A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric

More information

Effective Date: July 2010 Void After: July Product: Push Fit Fittings File No. 4630

Effective Date: July 2010 Void After: July Product: Push Fit Fittings File No. 4630 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

3M Pressurized Closure System 2-Type 505

3M Pressurized Closure System 2-Type 505 Communication Markets Division 3M Pressurized Closure System 2-Type 505 The 3M Pressurized Closure System 2-Type 505 is a complete, pressuretight, re-enterable closure system for enclosing spliced connections

More information

KVT Split cable glands

KVT Split cable glands KVT Split cable glands Description Type Order Inserts KT Thread PU No. small large Thread length KVT is a circular split frame for quick and easy installation of cables or complete cable harnesses. Polyamide

More information

Public Works Division Lighting District Fiber Optic Specifications April 2009

Public Works Division Lighting District Fiber Optic Specifications April 2009 Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks

More information