Specifications. Contents

Size: px
Start display at page:

Download "Specifications. Contents"

Transcription

1 s Contents Air handling units Cooling Units Unit sections Duct accessories, uninsulated Duct accessories, in insulated casing Mixing section, GOLD SD Hoods Component box Filter Outdoor installation Extra accessories We reserve the right to alter specifications

2 GOLD RX Air handling unit, rotary heat exchanger GOLD Size: 04, 05, 07, 08, 11, 12, 14, 20, 25, 30, 35, 40, 50, 60, 70, 80, 100, 120 Part no. for stock variants E GOLD-aa-b-RX Fan arrangement: Fan arrangement 1 Fan arrangement 2 (sizes 12-80) Fan arrangement 4 (sizes 04-08, vertical assembly) Surface treatment on rotor: Standard Hygroscopic Epoxy treated Capacity variant: 1 2 (Applicable to sizes 05, 08, 12, 20, 30, 60, 80, 120) Connection upward None Intake (sizes 14-30) Discharge (sizes 14-40) Intake and discharge (sizes 14-30) Air recirculation section: (sizes 50-80) Air discharge direction, upper fan (sizes ) End connection: (four choices) Base beams (optional sizes Prefilter, supply air: Prefilter, extract air: Forward Upward G4 Aluminium G4 Aluminium GOLD GOLD-aa-E-RX-d-e-f-g-h-i Size: 04, 05, 08, 12, 14, 20, 25, 30, 35, 40 Fan arrangement: Fan arrangement 1 = 1 Fan arrangement 2 = 2 = 1 = 2 Upper left-hand end = 0 connection panel: = 1 Lower left-hand end = 0 connection panel: = 1 Upper right-hand end = 0 connection panel: = 1 Lower right-hand end = 0 connection panel: = We reserve the right to alter specifications

3 GOLD RX Top Air handling unit, rotary heat exchanger GOLD Size: 04, 05, 07, 08, 11, 12 Surface treatment on rotor: Base beams (optional sizes Standard Hygroscopic Epoxy treated E GOLD-aa-b-RX-TOP Part no. for stock variants GOLD GOLD-aa-E-RX-d-e-TOP Size: 04, 05, 08, 12 Fan arrangement: Fan arrangement 2 = 2 = 1 We reserve the right to alter specifications

4 GOLD PX Air handling unit, plate heat exchanger GOLD GOLD-aa-b-PX Size: 04, 05, 07, 08, 11, 12, 14, 20, 25, 30 Surface treatment on heat exchanger Temperature Efficiency Standard Epoxy treated High efficiency (MTE) Normal efficiency (MPE) Capacity variant: 1 2 (applies to sizes 05, 07, 08, 11, 12, 20, 30) Connection upward None Intake, left-hand (sizes 14-30) Intake, right-hand (sizes 14-30) Intake, left-hand and right-hand (sizes 14-30) End connection panel: (four choices) Prefilter, supply air: Prefilter, extract air: G4 Aluminium G4 Aluminium E 252 We reserve the right to alter specifications

5 GOLD CX Air handling unit, coil heat exchangers GOLD Size: 35, 40, 50, 60, 70, 80, 100, 120 E GOLD-aa-b-CX Fan arrangement: Fan arrangement 1 Fan arrangement 2 Fan arrangement 4 (Applicable to size 100/120 only) Fan arrangement 5 (applies to size 100/120 only) Supply air in upper level (applies to size 100/120 only, fan arrangements 4 and 5) Supply air in lower level (applies to size 100/120 only, fan arrangements 4 and 5) Capacity variant: 1 2 (applies to sizes 60, 80, 120 only) Air recirculation section: (sizes 50-80) Air discharge direction upper fan Droplet eliminator Filling (does not apply: to sizes 100/120) End connection panel: (four choices) Prefilter, supply air: Prefilter, extract air: Forward Upward 30% ethylene glycol Empty G4 Aluminium G4 Aluminium Pipework package TBXZ-3-42-aa Unit size: Floor stand for the pipework package TBXZ-2-43-a Unit size: = 2 Water trap TBXZ-1-40-a Plate heat exchanger = 1 Coil heat exchanger = 2 We reserve the right to alter specifications

6 GOLD SD Air handling unit GOLD SD GOLD-aa-b-SD Size: 04, 05, 07, 08, 11, 12, 14, 20, 25, 30, 35, 40, 50, 60, 70, 80, 100, 120 Type of control equipm. E Including control unit Excluding the control unit (used if two air handling units can be controlled by the same control unit.) F7 Pipework package Filter section (Appl. to sizes only) Coil heat exchanger (applies to sizes, supply air handling unit only), extract air handling unit Droplet eliminator (applies to sizes only) Version Capacity variant: 1 2 (applies to sizes 05, 08, 12, 20, 30, 60, 80, 120 only) Connection upward None Discharge (sizes ) End connection panel: (two options) Base beams (optional sizes Prefilter: G4 Aluminium Unit size: 12, Floor stand for the pipework package Unit size: 12, 14, 20 = = 2 TBXZ-3-42-aa TBXZ-2-43-a Part no. for stock variants GOLD GOLD-aa-E-SD-d-e-f-g-h-i Size: 04, 05, 08, 14, 20 Including control unit = 1 Excluding control unit = 2 Filter section: = 0, F7 = 1 Coil heat exchanger = 0 = 1 = 2 End connection panel, = 0 left-hand side: = 1 End connection panel, = 0 right-hand side: = We reserve the right to alter specifications

7 Substitute material Set of filters, bag, GOLD RX/PX/CX For one airflow direction TBFZ-2-01-aa-b Set of filters, pleated filters, GOLD RX Top TBFZ-1-09-a For one airflow direction. For unit sizes: Filter class: F7 = 7 Set of filters, bag, GOLD RX/PX/CX For one airflow direction For unit sizes: Filter class: F7 = 7 Set of filters, pleated filter, 300 mm TBFZ-1-03-aa-b For one airflow direction, to GOLD RX/PX 14-30, air inlet from above. For unit size: Filter class: F7 = 7 Set of filters, pleated filters, GOLD SD For one airflow direction For unit sizes: Filter class: F5 = 5 F7 = 7 Set of filters, bag, GOLD SD For one airflow direction For unit sizes: TBFZ-3-01-aa-b TBFZ-1-05-aa-b TBFZ-1-06-aa-b Size Set of filters, prefilters TBFA For one airflow direction Connection size: Ø 315 = Ø 400 = Ø 500 = x400 = x500 = x600 = x800 = x1000 = x1200 = Filter type: Aluminium = 1 Compact = 2 Set of filters, pre-filter in intake air section TBTF For one airflow direction Size Set of filters, carbon filters For one airflow direction. Size 17 = = = = = = 098 TBFZ-1-08-aaa-aaa-b TBFZ-2-10-aa TBFZ-1-11-aaa Filter class: F7 = 7 We reserve the right to alter specifications

8 Set of filters, bag, TCFB final filter section TBFZ-1-14-aa-b For one airflow direction For unit sizes: 35, 49 = 40 Filter class: F7 = 7 F9 = 9 Set of filters, pre-filter in the GOLD RX/PX/CX unit For one airflow direction TBFZ-1-15-aa-b For unit sizes: Filter type: Compact = 1 Aluminium = 2 Set of filters, pre-filter in the GOLD SD unit For one airflow direction TBFZ-1-16-aa-b For unit sizes: Filter type: Compact = 1 Aluminium = We reserve the right to alter specifications

9 Cooling Units COOL DX Cooling unit COOLDX-aa-b-c-d-e-f-g COOL DX Top cooling unit COOLDXTOP-aa-b-c-d-1 For GOLD, size: = F Capacity variant 1 = 1 2 = 2 3 (Not sizes 08 and 12) = 3 For GOLD, size: = E Capacity variant 1 = 1 2 = 2 Location of air cooler Supply air, right-hand = 1 Supply air, left-hand = 2 Location of air cooler Upper level = 1 Lower level = 2 Inspection side = 1 = 2 End connection panel, upper level = 0 (side facing outw.) = 1 (both sides) = 2 End connection panel, lower level = 0 (side facing outw.) = 1 (both sides) = 2 Accessories Base for the CoolDX For CoolDX, size 08 Base for the CoolDX For unit size: 08 = = = = = = = 80 Filter class: F7 = 7 Water trap For CoolDX TBLZ-2-44 TBFZ-2-02-aa-b TBXZ Base beams, COOL DX, size 08 TBXZ-1-77 The base beams are standard for the other sizes. We reserve the right to alter specifications

10 Unit sections Air recirculation section For return air. Size Fan arrangement 1 2 GOLD size (TCBP-1-12 only) Capacity variant (GOLD size 11 only) 1 2 Air bypass section For rerouting the extract air to bypass the heat exchanger and filter Size Configuration*: Fan arrangement 1 2 GOLD size (TCBP-1-12 only) Capacity variant (GOLD size 11 only) 1 2 TCBR-1-aa TCBP-1-aa * The air bypass section can be selected for the GOLD RX/CX only, sizes 11-40, with extract air fan in the upper level, i.e. with configuration Fan arrangement 1/ version or Fan arrangement 2/ version. Damper Damper with motor TBSA-X-aaa-aaa-b-c Ductwork leakage class 3 Version Version 1* = 1 Version 3** = 3 Duct connection size: Ø 315 = Ø 400 = Ø 500 = x400 = x500 = x600 = x800 = x1000 = x1200 = x800*** = Damper blades: Uninsulated (not ) = 1 Insulated = 2 (rectangular dampers only) Damper motor: spring return = 1 On/Off = 2 Modulating with spring return = 3 (Rect. damper and 500 mm dia. only) * Duct connection size: , , ** Duct connection size: , , , , , , *** For GOLD sizes 100/120 with fan outlet for upward air discharge. Sound attenuator Air handling unitsound attenuator TBDA-1-aaa-aaa-bbb Duct connection size Ø 500 = x400 = x500 = x600 = x800 = x1000 = x1200 = Length: For sound attenuator: 1,200 mm Ø 500 = mm 1000x400 = mm 1200x500 = mm 1400x600 = mm 1600x800 = 065 1,250 mm 1800x1000 = 125 1,250 mm 2400x1200 = We reserve the right to alter specifications

11 Vent. unitsound attenuator Duct connection size Ø 315 = Ø 400 = Length: For sound attenuator: 800 mm Ø 315 = 080 1,100 mm Ø 400 = 110 Air heater (coil) Air heater for hot water (size 05-12) Connection dimensions: Ø 315 = Ø 400 = Ø 500 = TBDA-2-aaa-aaa-bbb TBLA-5-aaa-aaa-b-c Set of valves, heating TBVL-2-aaa 2(3)-way valve including actuator, cable and insertion sensor Not used for the Xzone control function. See the TBVA valve set. (If the liquid flow exceeds 2.5 l/s, pls. contact Swegon) Valve size: Kvs 0.25 = 002 Kvs 0.40 = 004 Kvs 0.63 = 006 Kvs 1.0 = 010 Kvs 1.6 = 016 Kvs 2.5 = 025 Kvs 4 = 040 Kvs 6.3 = 063 Kvs 10 = 100 Kvs 16 = 160 Kvs 25 = 250 Standard = 2 Set of electrical connections: For water coil TBLZ-1-27-a Capacity variant: Capacity variant 1 = 1 (standard version) Capacity variant 2 = 2 (Applicable to size 400 and 500 mm dia. only) Air heater for hot water (size 05-40) Connection dimensions: Ø 315 = Ø 400 = Ø 500 = x400 = x500 = x600 = TBLA-4-aaa-aaa-b-c Thermoguard = 1 (cap. variant 1 only) Standard = 2 (Applicable to sizes 1000x x600 only) Cable, resistor and insertion sensor. = 1 Cable, resistor and snap-on sensor. = 2 Circulation pump TBPA-5-aaa Set of pump components for the secondary side for air heater without anti-frost protection, including non-return valve and commissioning valve. Capacity at max 25 kpa pressure drop in air heater and pipework: < 0.09 l/s = l/s = l/s = l/s = l/s = l/s = l/s =250 Capacity variant: Capacity variant 1 = 1 (applicable to size Ø 500, standard version only) Capacity variant 2 = 2 (applicable to size 1000x x600, standard version only) Capacity variant 3 = 3 (applicable to size 1000x x600, standard version only) We reserve the right to alter specifications

12 Air heater for preheating, hot water TBLF-1-aaa-aaa Including control components, TBLZ Connection size: Ø 315 = Ø 400 = Ø 500 = x400 = x500 = x600 = x800 = x1000 = Valve set for cooling and heating TBVA-1-aaa 2(3)-way valve incl. actuator. Also used for the Xzone control function with the TBLA air heater (The SEBG pipework package is recommended for liquid flows exceeding 5 l/s.) Valve size Kvs 0,25 = 002 Kvs 0,40 = 004 Kvs 0,63 = 006 Kvs 1,0 = 010 Kvs 1,6 = 016 Kvs 2,5 = 025 Kvs 4 = 040 Kvs 6,3 = 063 Kvs 10 = 100 Kvs 16 = 160 Kvs 25 = 250 Kvs 40 = 400 Kvs 49 = 490 Kvs 63 = 630 Kvs 78 = 780 Valve set, cooling and heating TBVA-1-aaaa 2(3)-way valve including actuator. Used also for the XZone control function with TBLA air heater. Valve size: Kvs 100 = 1000 Kvs 124 = 1240 Kvs 160 = 1600 Electric air heater TBLE-3-aaa-aaa-bbb-c Including built-in controller and connection cable with quick connector Duct connection dimensions: Ø 315 = Capacity variant: For air heater: 3.0 kw Ø 315 = kw Ø 315 = kw Ø 315 = 075 Voltage: 400V = 1 230V (Norway) = 2 Electric air heater TBLE-4-aaa-aaa-bb-c Including built-in controller and connection cable with quick connector Duct connection dimensions: Ø 315 = Ø 400 = Ø 500 = x400 = x500 = x600 = Capacity variant: For air heater: 12 kw Ø 315 = kw Ø 315 = kw Ø 315 = kw Ø 400 = kw Ø 400 = kw Ø 400 = kw Ø 400 = kw Ø 400 = kw Ø 400 = 47 8 kw Ø 500 = kw Ø 500 = kw Ø 500 = kw Ø 500 = kw Ø 500 = kw Ø 500 = kw Ø 500 = kw 1000x400 = kw 1000x400 = kw 1000x400 = kw 1000x400 = kw 1000x400 = kw 1000x400 = kw 1000x400 = kw 1200x500 = kw 1200x500 = kw 1200x500 = kw 1200x500 = kw 1200x500 = kw 1200x500 = kw 1200x500 = kw 1200x500 = kw 1400x600 = kw 1400x600 = kw 1400x600 = kw 1400x600 = kw 1400x600 = kw 1400x600 = kw 1400x600 = kw 1400x600 = 90 Voltage: 400V = 1 230V (Norway) = We reserve the right to alter specifications

13 Cooling coil Air cooler for chilled water (sizes 04-12) TBKA-4-aaa-aaa-b Valve set for cooling and heating 2 (3)-way valve including actuator. TBVA-1-aaa Connection dimensionn: Ø 315 = Ø 400 = Ø 500 = Capacity variant: Capacity variant 1 = 1 Capacity variant 2 = 2 Capacity variant 5 = 5 (Size Ø 500 only) Capacity variant 6 = 6 (Size Ø 500 only) Air cooler for chilled water (sizes 14-40) Connection dimensionn: 1000x400 = x400 = x500 = x500 = x600 = x600 = Capacity variant: Capacity variant 1 = 1 (not sizes 1200x400, 1400x500, 1600x600) Capacity variant 2 = 2 (Not sizes 1200x400, 1400x500, 1600x600) Capacity variant 3 = 3 (Sizes 1000x400, 1200x500, 1400x600 only) Capacity variant 4 = 4 (Sizes 1200x400, 1400x500, 1600x600 only) TBKA-5-aaa-aaa-b Valve size: Kvs 0,25 = 002 Kvs 0,40 = 004 Kvs 0,63 = 006 Kvs 1.0 = 010 Kvs 1.6 = 016 Kvs 2.5 = 025 Kvs 4 = 040 Kvs 6.3 = 063 Kvs 10 = 100 Kvs 16 = 160 Kvs 25 = 250 Kvs 40 = 400 Kvs 49 = 490 Kvs 63 = 630 Kvs 78 = 780 Valve set, cooling and heating 2(3)-way valve including actuator. Valve size: Kvs 100 = 1000 Kvs 124 = 1240 Kvs 160 = 1600 Air cooler, direct expansion (sizes 04-40) Version* = 3 = 4 Connection dimensions: Ø 315 = Ø 400 = Ø 500 = x400 = x500 = x600 = Capacity variant: Capacity variant 1 = 1 Capacity variant 2 = 2 (size 1000x x600 only) Capacity variant 3 = 3 (size Ø 500, 1200x x600 only) TBVA-1-aaaa TBKC-a-bbb-bbb-c-d Number of sections: 1 section = 1 2 sections = 2 (size 1000x x600 only) * 4 = TBKC , TBKC , TBKC TBKC = Others Water trap TBXZ We reserve the right to alter specifications

14 Duct accessories, in insulated casing Damper with motor TCSA-a-bb Spacer section TCGA-a-bb Version = 3 Size: Damper motor: Spring return On/Off Modulating Damper blades: Uninsulated Insulated Location of AHU end connection (viewed from insp. side): Location (sizes 20-40): Against fan Against filter Duct location (sizes 60-80): Lower level Upper level Version =1, 2* Size: Location of AHU end connection (viewed from insp. side): Duct location (sizes 60-80): Lower level Upper level Location (sizes 20-40): Against fan Against filter End connection panel: Base beams (optional for sizes 05-08, * Sizes 60 and 120 = version 1, other sizes are version 2 End connection panel: Base beams (optional for sizes 05-08, 262 We reserve the right to alter specifications

15 Inspection section TCIA-a-bb Sound attenuator TCDA-a-bb Version = 1 Size: Location of AHU end connection (viewed from insp. side): Cover panel: (all sizes) (sizes 05-40) Duct location (sizes 60-80): Lower level Upper level Location (sizes 20-40): Against fan Against filter End connection panel: Base beams (optional for sizes 05-08, Version =1, 2* Size: Location: Against fan Against filter Location of AHU end connection (viewed from insp. side): Duct location (sizes 60-80): Lower level Upper level End connection panel: Base beams (optional for sizes 05-08, * Size 80 = version 2, other sizes are version 1. We reserve the right to alter specifications

16 Air heater for hot water: Air heater, preheat, water Incl. TBLZ control system Size: Location of AHU end connection (viewed from inspection side): End connection panel: Base beams (optional for sizes 05-08, TCLA-a-bb Version =1, 2* Size: Capacity variant: Capacity variant 1 Capacity variant 2 Capacity variant 3 Casing only (sizes ) Location of AHU end connection (viewed from insp. side): Fan location (sizes 60-80) 1 2 End connection panel: Base beams (optional for sizes 05-08, * Size 80 = version 2, other sizes are version 1. TCLF-1-bb Valve set, cooling and heating 2(3)-way valve including actuator. Used also for the XZone control function with TBLA air heater. Valve size: Kvs 0.25 = 002 Kvs 0.40 = 004 Kvs 0.63 = 006 Kvs 1.0 = 010 Kvs 1.6 = 016 Kvs 2.5 = 025 Kvs 4 = 040 Kvs 6.3 = 063 Kvs 10 = 100 Kvs 16 = 160 Kvs 25 = 250 Kvs 40 = 400 Kvs 49 = 490 Kvs 63 = 630 Kvs 78 = 780 Valve set, cooling and heating 2(3)-way valve including actuator. Valve size: Kvs 100 = 1000 Kvs 124 = 1240 Kvs 160 = 1600 Valve set, heating 2(3)-way valve including actuator, cable and insertion sensor Not used for the XZone control function, see TBVA valve kit. (If the liquid flow exceeds 2.5 l/s, contact Swegon) Valve size: Kvs 0.25 = 002 Kvs 0.40 = 004 Kvs 0.63 = 006 Kvs 1.0 = 010 Kvs 1.6 = 016 Kvs 2.5 = 025 Kvs 4 = 040 Kvs 6.3 = 063 Kvs 10 = 100 Kvs 16 = 160 Kvs 25 = 250 TBVA-1-aaa TBVA-1-aaaa TBVL-2-aaa 264 We reserve the right to alter specifications

17 Set of electrical connections: For air heater for hot water Cable, resistor and insertion sensor. = 1 Cable, resistor and strap on sensor = 2 Electric air heater Version =1, 2* Size: Fan location (sizes 60-80) 1 2 Cap. variant: Size: 3 kw 04/ kw 04/ kw 04/05 12 kw 04/05 6 kw 07/08 12 kw 07/08 20 kw 07/08 (400 V only) * Size 80 = version 2, other sizes are version 1. TBLZ-1-27-a Circulation pump TBPA-5-aaa Set of pump components for the secondary side for air heater without anti-frost protection, including non-return valve and commissioning valve. Capacity at max 25 kpa pressure drop in air heater and pipework: < 0.09 l/s = l/s = l/s = l/s = l/s = l/s = l/s =250 TCLE-a-bb 27 kw 07/08 (400 V only) 8 kw 11/12 12 kw 11/12 20 kw 11/12 27 kw 11/12 36 kw 11/12 8 kw kw kw kw kw 20 (400 V only) 69 kw 20 (400 V only) 12 kw kw kw kw kw kw 30 (400 V only) 12 kw kw kw kw kw kw kw 50/60 34 kw 50/60 47 kw 50/60 63 kw 50/60 79 kw 50/60 90 kw 50/60 (400 V only) 135 kw 50/60 (400 V only) 34 kw 70/80 45 kw 70/80 55 kw 70/80 69 kw 70/80 90 kw 70/ kw 70/ kw 100/120 (230 V only) 50 kw 100/120 (400 V only) 67.8 kw 100/120 (400 V only) 70 kw 100/120 (230 V only) 97.6 kw 100/120 (230 V only) 100 kw 100/120 (400 V only) 150 kw 100/ kw 100/ kw 100/120 Casing only, 632 mm (sizes 50-80) Casing only, 792 mm (sizes 50-80) Casing only (sizes ) Voltage: 230 V 400 V Location of AHU end connection (viewed from insp. side): End connection panel: Base beams (optional for sizes 05-08, We reserve the right to alter specifications

18 Air cooler, water Valve set, cooling and heating 2(3)-way valve including actuator. Valve size: Kvs 0.25 = 002 Kvs 0.40 = 004 Kvs 0.63 = 006 Kvs 1.0 = 010 Kvs 1.6 = 016 Kvs 2.5 = 025 Kvs 4 = 040 Kvs 6.3 = 063 Kvs 10 = 100 Kvs 16 = 160 Kvs 25 = 250 Kvs 40 = 400 Kvs 49 = 490 Kvs 63 = 630 Kvs 78 = 780 TCKA-a-bb Version = 3,4* Size: Fan location (sizes 60-80) 1 2 Capacity variant: Capacity variant 1 Capacity variant 2 Capacity variant 3 (not applicable to size 04-12, 60) Capacity variant 4 (not applicable to size 60) Capacity variant 5 (size 60) Capacity variant 6 (size 60) Casing only, 570 mm (sizes 50-80) Casing only, 792 mm (sizes 50-80) Casing only (sizes 120) Droplet eliminator: Location of AHU end connection (viewed from insp. side): End connection panel: Base beams (opt. for sizes 05-08, std for the other sizes) * 3 = sizes 04-12, = sizes TBVA-1-aaa Valve set, cooling and heating 2(3)-way valve including actuator. Valve size: Kvs 100 = 1000 Kvs 124 = 1240 Kvs 160 = 1600 Air cooler, direct expansion Version = 3 Size: Fan location (sizes 60-80) 1 2 Capacity variant: Capacity variant 1 Capacity variant 2 Capacity variant 3 (size 50-80) Casing only, 570 mm (sizes 50-80) Casing only, 792 mm (sizes 50-80) Number of sections: Casing only (sizes 50-80) 1 section 2 sections (not applicable to sizes 04-08) Droplet eliminator: Location of AHU end connection (viewed from inspection side): End connection panel: Base beams (optional for sizes 05-08, Water trap TBVA-1-aaaa TCKC-a-bb TBXZ We reserve the right to alter specifications

19 Coil section, heating (water) and cooling Version = 4 Size: TCLK-a-bb Fan location (sizes 60-80) 1 2 Capacity variant, air cooler, water: Capacity variant 1 Capacity variant 2 Capacity variant 3 Type of air cooler: Water Direct expansion air cooler, 570 mm (sizes 50-80) air cooler, 792 mm (sizes 50-80) air cooler (size 120) Capacity variant, air cooler, water: Capacity variant 1 Capacity variant 2 Capacity variant 3 (not applicable to size 60) Capacity variant 4 (not applicable to size 60) Capacity variant 5 (size 60) Capacity variant 6 (size 60) Capacity variant, air cooler, direct expansion: Capacity variant 1 Capacity variant 2 Capacity variant 3 (size 50-80) Number of sections, air cooler, direct expansion: 1 section 2 sections (not applicable to sizes 04-08) Sequence (viewed in direction of airflow): Heating, cooling Cooling, heating Droplet eliminator: Location of AHU end connection (viewed from insp. side): End connection panel: Base beams (optional for sizes 05-08, Coil section, heating (electric) and cooling TCEK-a-bb Version = 3 Size: Fan location (sizes 60-80) 1 2 Cap. variant: Size: 3 kw 04/ kw 04/ kw 04/05 12 kw 04/05 6 kw 07/08 12 kw 07/08 20 kw 07/08 (400 V only) 27 kw 07/08 (400 V only) 8 kw 11/12 12 kw 11/12 20 kw 11/12 27 kw 11/12 36 kw 11/ kw 11/12 69 kw 11/12 8 kw kw kw kw kw 20 (400 V only) 69 kw 20 (400 V only) 12 kw 30 Contd. on next page We reserve the right to alter specifications

20 20 kw kw kw kw kw 30 (400 V only) 12 kw kw kw kw kw kw kw 50/60 34 kw 50/60 47 kw 50/60 63 kw 50/60 79 kw 50/60 90 kw 50/60 (400 V only) 135 kw 50/60 (400 V only) 34 kw 70/80 45 kw 70/80 55 kw 70/80 69 kw 70/80 90 kw 70/ kw 70/ kw 100/120 (230 V only) 50 kw 100/120 (400 V only) 67.8 kw 100/120 (400 V only) 70 kw 100/120 (230 V only) 97.6 kw 100/120 (230 V only) 100 kw 100/120 (400 V only) 150 kw 100/ kw 100/ kw 100/120 air heater, 632 mm (sizes 50-80) air heater, 792 mm (sizes 50-80) air heater (size 120) Voltage: 230 V 400 V Capacity variant, air cooler, direct expansion: Capacity variant 1 Capacity variant 2 Capacity variant 3 (size 50-80) Number of sections, air cooler, direct expansion: 1 section 2 sections (not applicable to sizes 04-08) Sequence (viewed in direction of airflow): Heating, cooling Cooling, heating Droplet eliminator: Location of AHU end connection (viewed from insp. side): End connection panel: Base beams (optional for sizes 05-08, Type of air cooler: Water Direct expansion air cooler, 570 mm (sizes 50-80) air cooler, 792 mm (sizes 50-80) air cooler (size 120) Capacity variant, air cooler, water: Capacity variant 1 Capacity variant 2 Capacity variant 3 (not applicable to size 60) Capacity variant 4 (not applicable to size 60) Capacity variant 5 (size 60) Capacity variant 6 (size 60) 268 We reserve the right to alter specifications

21 Mixing section, GOLD SD Final filter section TCFB-a-bb Mixing section for GOLD SD TBBD-1-aa-b-c Version =1 Size: Fan location (sizes 60-80) 1 2 For unit size Variant: Two dampers = 1 Three dampers = 2 Version Alternative 1 = 1 Alternative 2 = 2 (for three dampers only) Location of AHU end connection (viewed from insp. side): Filter class F9 F7 End connection panel: Base beams (optional sizes 05-08, Mixing section for GOLD SD For unit size Variant: Two dampers = 1 Three dampers = 2 Version Alternative 1 = 1 Alternative 2 = 2 (for three dampers only) TBBD-2-aa-b-c We reserve the right to alter specifications

22 Hoods Filters Outdoor air hood Including roof duct For unit size: 04, 05 = , 08 = , 12 = , 20 = , 30, 35, 40 = 0909 TBHA-1-aaaa Carbon filter Number of carbon filter cartridges 17 = = = = = = 098 TBFK-3-aa-b Exhaust air hood Including roof duct For unit size: 04, 05 = , 08 = , 12 = , 20 = , 30, 35, 40 = 0909 Dual-purpose hood Including roof duct For unit size: 04, 05 = , 08 = , 12 = 0050 Exterior Wall Hood For unit size: 04, 05 = , 08 = , 12 = 0050 Component box Component box Size: 05 = = = = 40 Inspection door: Right-hinged Left-hinged Base beams (optional extra for size 05, standard on the other sizes): Roof for the component box Size of component box: 05 = = = = 40 TBHB-1-aaaa TBHC-1-aaaa TBHE-1-aaaa TCWP-1-aa TBTB-2-aa-WP Carbon filter cartridges:: = 0 = 1 Prefilter Connection size Ø 315 = Ø 400 = Ø 500 = x400 = x500 = x600 = x800 = x1000 = x1200 = Type of filter Aluminium = 1 Compact = 2 Pressure transducer TBLZ-1-23-aa Contains pressure transducer and connection cable. 1 m = 01 3 m = 03 5 m = m = m = 15 TBFA-1-aaa-aaa-b 270 We reserve the right to alter specifications

23 Outdoor installation Roof for outdoor installation GOLD RX/PX/CX TBTB-2-aa-bb-c Complete with necessary assembly parts For unit sizes:. Unit type RX PX CX SD Accessory, TCWP Version D = RX = PX = CX = SD = WP = D Intake air section for outdoor installation TBTA-3-aa-b-1 Complete with water separator and fastening device. The damper can be installed inside the section. For unit sizes: Design Grille = 1 Exhaust air hood for outdoor installation TBTA-2-aa-2 Complete with wire mesh and fastening device For unit sizes: Cover hood, GOLD CX pipework package TBXZ-1-41-aa Intake air section for outdoor install. TBTF-2-aa-b-c-d Complete with fastening device. The damper and pre-filter are available installed inside the section on delivery. For unit sizes: 35,40 = 40 Damper, = 1, actuator with spring return = 2, modulating damper actuator = 3 Prefilter = 1 = 2 Design = 1 = 2 For unit sizes: Countersink kit for supply air temperature sensor Used for internally insulated ducts. TBLZ-1-65 We reserve the right to alter specifications

24 Extra Accessories Mechanical equipment Electrical and control equipment Stand, GOLD RX Mounting kit TBLZ-2-aa-02 Extension cable quick-fit connector TBLZ-1-05-a For unit size: Stand, GOLD SD Mounting kit. For unit size: Legs,GOLD PX GOLD Air handling units, sizes 04-40: Cover holder For unit sizes 04, 05 and 08 TBLZ-2-aa-04 TBLZ-1-43 Base frame, CoolDX TBLZ-1-44 Used also as a base beam for the CoolDX in combination with the GOLD PX Slip-clamp jointing flanges Set of one connection For unit sizes: Metu connec-tion Connection size: 1000x400 = x500 = x600 = x800 = x1000 = x1200 = TBLZ TBLZ-2-aa-08 TBXZ-1-aaa-aaa-10 5 m long for air heater, water and electric = 1 8 m for pressure sensor, TBIQ = 3 8 m, for hand-held micro terminal = 4 Connection cable For pressure sensor, TBIQ 0.25 m = 00 1 m = 01 3 m = 03 5 m = m = m = 15 Room Sensor For wall mounting. Enclosure Class IP 20. Sensor, outdoor/room Watertight for wall mounting, enclosure class IP43. Can also be used as a room sensor if specs require a higher enclosure class. TBLZ Pressure transducer TBLZ-1-23-aa Contains pressure transducer and connection cable. 1 m = 01 3 m = 03 5 m = m = m = 15 TBLZ-1-26-aa TBLZ Support foot, 1 pc. For bottom beam of unit sizes 11, 12, 14, 20, 25, 30, 35, 40, 50, 60, 70, 80, 100, 120 Rubber disc, 1 pc. For support foot TBXZ-1-36 TBXZ-1-37 Elevating block for base beams TBXZ-1-78 For insulated duct accessories in combination with the GOLD PX, sizes We reserve the right to alter specifications

25 SD card TBLZ-1-62-a Flash card for program transmissions and logging software = 1 software, GOLD = 2 software, GOLD program version 5.16 = 4 software, GOLD version E = 5 Separate cubicle for smoke function Including control unit for smoke detector = 1 Including control unit for smoke detector and damper installation = 2 TBLZ-1-48-a Separate cubicle for smoke function TBLZ Including control unit for smoke detector and damper exercising, damper: 24 V AC Transformer, 230/400 V For connecting the air handling unit to 230V mains power supply Transformer output: 7 kva = kva = kva = kva = kva = kva = kva = kva = kva = kva = 87 Transformer 230/24 VAC Timer, electronic TBLZ-2-aa-11 TBLZ-1-46 TBLZ-1-47 Smoke detector, optical Venturie tube 600 mm = mm = 2 Mounting fittings for smoke detector, for circular or insulated ducts Damper actuator spring return Timer 0-2 hour prolonged operation For strap-on mounting = 1 TBLZ-2-49-a TBLZ-1-53 TBLZ-1-69 ELQZ a IQlogic + Functional module and connection cable Size Small = 1 Medium = m = 00 1 m = 01 3 m = 03 5 m = m = m = 15 TBIQ-3-a-bb External duct temperature sensor, IQlogic + TBLZ-1-30 Humidity sensor For dehumidification and dew point control Measuring point: Supply air duct = 1 Extract air duct = 2 For coil heat exch. SD, extract air = 3 TBLZ-1-31-a Push button for prolonged operation ELQZ a-b For strap-on mounting = 1 indicating LED = 0 indicating LED = 1 Occupant detection sensor Internal duct temperature sensor Length of cable 1 m = 01 2,2 m = 02 4,3 m = 04 Air quality sensor, in-duct Air quality sensor, room TBLZ-1-56 TBLZ-1-58-aa ELQZ ELQZ We reserve the right to alter specifications

26 Control box for Xzone TBLZ-3-50-a-b-cc Control of one extra temperature zone, max. Freeze protection sensor = 0 = 1 Type of sensor Supply air = 1 Supply air/extract air = 2 Supply air/room air = 3 Connection cable 1 metre = 01 3 metres = 03 5 metres = metres = metres = 15 ReCO 2 TBLZ-2-51 Complete set of components for controlling the function for mixing. The pressure sensor and the IQlogic + are included. The air quality sensor must be ordered separately. The outdoor air damper must be of modulating type. The air handling unit must be equipped with an air recirculation section. Applicable to sizes only. Junction box conforming to IP54 For extension cable, TBLZ-1-05-a Battery eliminator For hand-held micro terminal Hand-held micro terminal Hand-held micro terminal WLAN = 1 WLAN = 2 TBLZ-1-61 TBLZ-1-70 TBLZ-1-71-a Control of air heater, preheating Including temperature sensor for duct and IQlogic + with 0.25 metre long cable TBLZ-2-53-a Freeze protection sensor = 0 = 1 All Year Comfort TBLZ-2-59-a-b-cc Control eq. cubicle for contr. the supply water flow. Operation Cooling control = 1 Heating control = 2 Cooling and heating control = 3 Room Sensor = 0 (GOLD RX/PX/CX/SD) = 1 (GOLD LP) = 2 Connection Cable 1 metre = 01 3 metres = 03 5 metres = metres = metres = 15 > 15 metres = xx 274 We reserve the right to alter specifications

Specifications. Contents

Specifications. Contents s Contents Air handling units... 250 Cooling Units... 257 Unit sections... 258 Duct accessories, uninsulated... 258 Duct accessories, in insulated casing... 262 Mixing section, GOLD SD... 269 Hoods...

More information

Installation Operation Maintenance

Installation Operation Maintenance Installation Operation Maintenance Rooftop Energy Recovery Module for TKD / TKH / WKD / WKH YKD / YKH / DKD / DKH # 125-155-175-200 250 265-290-340 # 275-300-350-400-500-600 April 2011 RT-SVX42B-E4 General

More information

ErP ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES ELECTRICAL SUPPLY AMBIENT TEMPERATURE RANGE SIZES MATERIAL AND DESIGN

ErP ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES ELECTRICAL SUPPLY AMBIENT TEMPERATURE RANGE SIZES MATERIAL AND DESIGN 161 ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES 8 sizes Volume flows up to 4.7 m 3 /s Static Pressures up to 1050 Pa Both EC- and AC-versions available Insulated and non-insulated casing Low sound level

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Küba comfort DP. Draught-free ventilation and extremely quiet operation

Küba comfort DP. Draught-free ventilation and extremely quiet operation Draught-free ventilation and extremely quiet operation engineering for a better world GEA Heat Exchangers Draught-free ventilation and extremely quiet operation Low air speed in the cold room Integrated

More information

PUR (A, B, C, D) AND PURR PRODUCT CODES FOR CASSETTE UNITS ROTOR SIZE

PUR (A, B, C, D) AND PURR PRODUCT CODES FOR CASSETTE UNITS ROTOR SIZE PUR (A, B, C, D) AND PURR ROTOR SIZE 030-250 2 Product codes ROTOR WITH CASING PUR A Rotor with casing, top/bottom airflow. Cassette type, with or without cover. PUR B Rotor with casing, side by side airflow.

More information

DM CONTROL MODULES (VCS-R-DM-..)

DM CONTROL MODULES (VCS-R-DM-..) EN-Installation manual 0 1 1/1 DM CONTROL MODULES (VCS-R-DM-..) VCS-R-DM-S, VCS-R-DM-E, VCS-R-DM-V B0-010-011-1 QUICK START INSTALLATION 1. BEFORE YOU BEGIN Symbols are used in the user s manual to improve

More information

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change without

More information

Nessie Coils for VDH and VDHT valves

Nessie Coils for VDH and VDHT valves Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of

More information

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade The space-saving helper in filling stations, gastronomy and the trade The space-saving helper in the positive and negative range Straightforward mounting Integrated air baffle plate Extremely space-saving

More information

Prodigy Eclipse ECC and EH222 Service Parts EH222 Cabinet - C Series

Prodigy Eclipse ECC and EH222 Service Parts EH222 Cabinet - C Series This part list contains the service parts for the Eclipse ECC 800 and 000 systems. Prodigy Plus D Series production began in late 0. The models that are covered include: EH - head ECC0800 - condensing

More information

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments Dual line system Designed to work all the day, every day in extreme condition and difficult environments CONTENTS Applications 3 Description 4 Operation 5 Benefits 6 TWIN pump 7 TWIN measures 8 TWIN-PUMP

More information

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate V3. Coolant systems are warranted for 1 year, parts and labor.

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate V3. Coolant systems are warranted for 1 year, parts and labor. Series Issued Oct. 2010 Index No. AY/7.2 Coolmate Coolant Systems Quick Specs Light/Heavy Industrial Applications Manufacturing Aerospace Automotive Tube Mills Automation Processes TIG (GTAW) MIG (GMAW)

More information

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd SINGLE ZONE CLIMATE ZONING SYSTEM Technical Manual Polyaire Pty Ltd 11-13 White Road GEPPS CROSS South Australia, 5094 Tel: (08) 8349 8466 Fax: (08) 8349 8446 www.polyaire.com.au CONTENTS Features 1 Application

More information

Contents Section 9, Illustrated Parts

Contents Section 9, Illustrated Parts Contents Section 9, Illustrated Parts Figures 9-1. Parts of RT7... 9-5 9-2. RT7 Drive Assembly... 9-9 9-3. RT7 Refrigeration System... 9-10 9-4. Parts of RT7 PLUS... 9-15 9-5. RT7 PLUS Drive Assembly...

More information

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow ...Simple Effective Inexpensive to operate Economical The Saudi Factory for Air Conditioning Units No air cooled condenser needed No chiller or cooling tower needed No major control center No refrigerant

More information

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A 3.1 Vacuum generation / / Convection cooled OktaLine Okta 500 with a pumping speed of 280 to 840 m 3 /h: High-performance Roots pump with a pumping speed of 280 to 840 m 3 /h With 3-phase motor, IE2 No

More information

Compact Vacuum Systems

Compact Vacuum Systems Compact Vacuum Systems Substantial savings can be realised by installing a compact central vacuum system from Dustcontrol. For example, all grinders and finishing tools in an production facility are equipped

More information

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12) MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL OPTEVA 868 THROUGH THE WALL ATM WITH 40mm ( 6") CEN III AND CEN IV SAFE L0 CALL -800--600 0 (6") REQUIRED FOR WALLS EXCEEDING 0mm (2") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS

More information

Actuator for dampers ACCESSORIES. Actuators for air dampers control in ventilation and air-conditioning systems.

Actuator for dampers ACCESSORIES. Actuators for air dampers control in ventilation and air-conditioning systems. SP Actuator for dampers CM230-1-F-L LF 230 TF 230 LM230A-TP LM24A-TP LM230A-SR-TP NM24A-TP NM230A-TP NM24A-SR-TP NF230A NF24A SF24A SF230A SF24A-SR SM230A-TP SM24A-TP SM24A-SR-TP ZAKP0027 ZAKP0039 ZAKP0063

More information

TOSHIBA Industrial Magnetron E3328

TOSHIBA Industrial Magnetron E3328 TOSHIBA E3328 is a fixed frequency continuous wave magnetron intended for use in the industrial microwave heating applications. The average output power is 3kW in the frequency range from 2450 to 2470

More information

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring

More information

General Specifications

General Specifications General Specifications WG41F11C Compact O Frame GS 14M04B10-20E-Z1 [Style: S1] Overview The WG41F11C Compact O frame is a space-saving frame designed for coating lines of battery electrode sheets. This

More information

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications. MIRAL The Admiral Type family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications. Its features include: Extremely easy connection and

More information

Agilent High Capacity RV Pumps & Roots Pumping Systems

Agilent High Capacity RV Pumps & Roots Pumping Systems Agilent High Capacity RV Pumps & Roots Pumping Systems 2-3 MS-Series Rotary Vane Pumps 4-5 RPS-Series Roots Pumping Systems and RPK-Series Roots Pumping Kits 6-7 Typical Applications 8-15 Pump Models MS-Series

More information

Just cool with green: GEA Küba market SP. The new standard for basic refrigeration applications

Just cool with green: GEA Küba market SP. The new standard for basic refrigeration applications Just cool with green: GEA Küba market SP The new standard for basic refrigeration applications engineering for a better world GEA Heat Exchangers GEA Küba market SP The new standard for basic refrigeration

More information

Heating films. Articelnumber build:

Heating films. Articelnumber build: Frenzelit GmbH 2018 Heating films The hicotherm 36 V heating film can be installed inconspicuously into a wall, ceiling and floor and brings a new feel-good experience to your home. Number Name Description

More information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page

More information

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460 Product Information Compact, ecological and economic Polydos 412 KD 440 Polydos 460 Polydos 412 three-chamber installations with PLC and graphic display Convenient preparation and dosing of dry or liquid

More information

Admiss. counterpressure

Admiss. counterpressure in survey Multi-layer diaphragm technology High dosing accuracy Safe to run dry High quality materials Leakage-free Low maintenance User-friendly Integrable into automatic processes Manual stroke length

More information

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview 13 6.3 13 6.3 4.7 20.7 24.6 +1/-0 24.6 +1/-0 2.5 24.6 +1/-0 20.7 4.3 +0.3-0.4 3.6 ±0.3 32.5 32.5 32.5 5 2 CONTACT-DUO-PROFILE Contact-Duo-Profile overview 13 6.3 13 6.3 4.7 2.5 16±0.8 4.7 2.5 4.7 2.5 2.6

More information

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12) MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL OPTEVA 868 THROUGH THE WALL ATM WITH mm ( 2") CEN-L SAFE L00 CALL -800-999-600 22 (9 6") REQUIRED FOR WALLS EXCEEDING 0mm (2") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

Ultra Quiet Series Electric Air Handler

Ultra Quiet Series Electric Air Handler Residential & Light Commercial HVAC Ultra Quiet Series Electric Air Handler 1 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz The Fedders multi-position air handlers, when matched with our air conditioners

More information

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe EFC, EFCe Systems Electronic Frequency Control Continuously variable speed control using frequency converter technology With the EFC and EFCe system Bock offers the most efficient means of adapting the

More information

15.0 Overview Cross Connection Cabinet KVS Overview Polyester Production Cross Connection Cabinet Unicab Vario 8

15.0 Overview Cross Connection Cabinet KVS Overview Polyester Production Cross Connection Cabinet Unicab Vario 8 15.0 Chapter-Content Page 15.0 Overview 2 15.1 KVS 3 15.2 Overview Polyester Production 7 15.3 Unicab Vario 8 23 15 http://www.krone-gmbh.at - Page 1 15.0 Overview KVS F3, KVS F4, KVS F5, KVS F6 Product

More information

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell

More information

OJ Air Pressure. full-range pressure and ventilation control FLOOR HEATING HYDRONIC HVAC CONTROLS & POWER FLOOR HEATING ELECTRIC

OJ Air Pressure. full-range pressure and ventilation control FLOOR HEATING HYDRONIC HVAC CONTROLS & POWER FLOOR HEATING ELECTRIC full-range pressure and ventilation control HVAC CONTROLS & POWER FLOOR HEATING ELECTRIC OJ Air Pressure FLOOR HEATING HYDRONIC VENTILATION CONTROLLERS AND PRESSURE TRANSMITTERS application specific solutions

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS CATALOG 495 APRIL 2013

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS   CATALOG 495 APRIL 2013 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS CATALOG 495 APRIL 2013 PLENUM FANS Models MPLFN MPLFS MPLQN MPLQS Twin City Fan & Blower

More information

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 % Main Applications Disinfection of Primary, secondary and tertiary treated wastewater effluents for discharge Wastewater for reuse (e.g. for irrigation of parks, agriculture) Process water for industrial

More information

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) 172.02.02 Excerpt from the Product Section C02 Edition March 2007 Contents General Product Range, Features and

More information

Küba Blue Line Aircoolers Küba SG commercial

Küba Blue Line Aircoolers Küba SG commercial Küba Blue Line Aircoolers Küba SG commercial Versatile solutions for standard Cooling rooms We are KelVion the new brand in heat exchange GEA Heat Exchangers has changed: another new standalone company

More information

Yet Another KW Amplifier for 432

Yet Another KW Amplifier for 432 Yet Another KW Amplifier for 432 Luis Cupido, CT1DMK Abstract: The Russian VHF triode GS35b is specified to operate up to 1000MHz with 1.5KW anode dissipation. Although the tube geometry makes the construction

More information

SAUTER flexotron RDT405 Manual

SAUTER flexotron RDT405 Manual SAUTER flexotron 400 - RDT405 Manual P100012100 Table of contents DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Fr. Sauter AG however, makes no warranties

More information

Product catalogue 2010

Product catalogue 2010 Product catalogue 2010 welding, cutting and more... www.kemper.eu Extraction systems for the electronic industry Soldering workstations... 153-154 Soldering smoke extraction systems... 155 Accessories

More information

Split System Air Conditioner

Split System Air Conditioner Residential & Light Commercial HVAC Split System Air Conditioner 1 R-410A, 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 2 to 5 tons

More information

OP5. Preprogrammed, configurable controller for simple applications

OP5. Preprogrammed, configurable controller for simple applications sect. pos. revision 3 020 08 2007 OP5 Preprogrammed, configurable controller for simple applications Optigo 5 is a new preprogrammed, configurable controller intended for DIN-mounting that can be set to

More information

Series 8800 Radial Tip Fans Design 8812

Series 8800 Radial Tip Fans Design 8812 Bulletin 8800-2 October 1996 Series 8800 Radial Tip Fans Design 8812 Description Index Series 8800 Radial Tip Fans The Design 8812 Radial Tip fan is a reliable, highly efficient, heavy duty, rugged fan

More information

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB September 2013 PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB The PACSystems * Thermocouple Input module IC695ALG412 provides twelve isolated differential thermocouple input channels.

More information

CME500 SERVICE PARTS

CME500 SERVICE PARTS This section contains the parts illustrations and parts lists for the CME500. CME500 ice machines are manufactured in both 115 volt, 60 cycle and 220 volt, 50 cycle. When ordering electrical parts, be

More information

Gear Pump Units For single-line centralized lubrication systems

Gear Pump Units For single-line centralized lubrication systems 1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST FANS. Model TVIFE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST FANS. Model TVIFE TURNING AIR INTO SOLUTIONS. 60 2 CA AM ted tes DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST S Model TVIFE CATALOG 1090 September 2016 LABORATORY EXHAUST S Overview TVIFE TVIFE Single Unit Twin City Fan

More information

UNIGAS Hand-held combustion gas analyzer with 3 sensors

UNIGAS Hand-held combustion gas analyzer with 3 sensors UNIGAS 2000 Hand-held combustion gas analyzer with 3 sensors Unigas 2000+ is a professional flue gas analyser for 3 gases: O 2, CO & NO with electrochemical sensors, plus CO 2 and NO x calculated. Description

More information

COMBINATION UNITS MARCH 2018

COMBINATION UNITS MARCH 2018 COMBINATION UNITS MARCH 2018 2 COMBINATION UNITS STATIONARY SOCKET OUTLET COMBINATIONS Variants 5 Dimensions 6 Wall-mounted Distributor Boxes (plastic) Series 45 8 Wall-mounted Distributor Boxes (plastic)

More information

SureFire PDI Lubricator

SureFire PDI Lubricator SureFire PDI Lubricator Automatic, Oil & Fluid Grease General The SureFire PDI Lubricator is an automatic, robust and durable pump that can handle oil and soft greases. Its compact size is designed to

More information

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED 0 INTRODUCTION Video Lift is an electro-mechanical device which, once installed in the ceiling, allows vertical movement (ceiling floor ceiling) for loads of up to 19 Kg and with maximum runs of 1 metre

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

Roof-mounted Blue e+ cooling unit Integration solution VX25

Roof-mounted Blue e+ cooling unit Integration solution VX25 Roof-mounted Blue e+ cooling unit Integration solution VX25 Ease of use Intuitive operation via touch display Integration solution VX25 and Blue e+ Cooling unit with 1.3 kw and Blue e+ technology with

More information

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 LINEAR ACTUATORS Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for

More information

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) Central Vacuum Supply Systems 172.02.02 Excerpt from the Product Section C02 Edition 2010 Contents General Product

More information

Sprite TL Quick Start Guide

Sprite TL Quick Start Guide Sprite TL Quick Start Guide with 115 VAC Power Cord and 4-Conductor Signal Cable Reference Manual Sprite TL Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com

More information

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor Oil Service Units ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor Easy filling, cleaning and pumping over Unbeatable ergonomics, optimal handling

More information

TUC: Universal thermostat

TUC: Universal thermostat Product data sheet 3.1 21.700 TUC: Universal thermostat How energy efficiency is improved Control, monitoring and limiting according to needs and with no auxiliary energy. Features Regulates and monitors

More information

AC diagonal module Ø 200 mm

AC diagonal module Ø 200 mm max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:

More information

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1. STRA communication The types of the signals (types in the list below): 1 = Coil Status Register ( function = 1, 5 and 15) - 0x 2 = Discrete Input ( function = 2) - 1x 3 = Holding Register ( function =

More information

Part-Turn Electric Multi-Turn Electric

Part-Turn Electric Multi-Turn Electric Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1

More information

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating - P550-3L Optional LS Upgrade #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency 400V, 50 Hz 480V, 60 Hz Prime Standby kva 500 550 kw 400 440 kva kw Ratings at 0.8 power factor. Please refer to the

More information

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance The Linatron -M is a modular system. The control console, modulator, and RF unit are common to all model configurations. Only the X-ray head changes to match the application. The Linatron - M is designed

More information

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB September 2013 PACSystems* RX3i Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB Isolated +24 VDC Power Isolated Thermocouple

More information

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division SPECIFICATION FIBER OPTIC SPLICE CLOSURE Model Spec. No. Distribution Depts. VSOF-BS403A VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division Sales Division Management Division Revision 10. 07 (Rev.4)

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

Product Information Product Information. CCFLs, CCFLs, Inverters Inverters & Accessories Accessories

Product Information Product Information. CCFLs, CCFLs, Inverters Inverters & Accessories Accessories Specialist suppliers of standard and custom CCFLs and Inverters Product Information Product Information for for CCFLs, CCFLs, Inverters Inverters & Accessories Accessories EEFL data coming soon! www.visualux.com

More information

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating - P400-3L Optional LS Upgrade #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency 400V, 50 Hz 480V, 60 Hz Prime Standby kva 350 400 kw 280 320 kva kw Ratings at 0.8 power factor. Please refer to the

More information

Air Conditioning Components and Equipments for Enclosures

Air Conditioning Components and Equipments for Enclosures Air Conditioning Components and Equipments for Enclosures Cooling Units Chillers Heat Exchangers Filterfans Heaters Thermostats Hygrostats Lamp Systems Components for Enclosures Pfannenberg Enclosure Air

More information

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion ES-Mega MegaBeans Access Control System User Manual / Order No. Device People in Motion Contents 1. General description..3 2. Installation Instructions..4 3. Start-up..4 4. Audible signals..4 5. Operating

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

e-vap 3kW Evaporation Sources

e-vap 3kW Evaporation Sources Thin Film Products e-vap 3kW Evaporation Sources e-vap Miniature Source 0413-0004-1002 3kW electron beam evaporation source. Flange mounted on 2.75 diameter CF type flange with HV and Water feedthroughs

More information

THE MODERN HVAC SYSTEM. J. Michael Carson P.E. Senior Mechanical Engineer Purdue University

THE MODERN HVAC SYSTEM. J. Michael Carson P.E. Senior Mechanical Engineer Purdue University THE MODERN HVAC SYSTEM J. Michael Carson P.E. Senior Mechanical Engineer Purdue University Btu Ton Heat Gain & Heat Loss Air Handling Unit Fan Air Distribution Preheat Coil Cooling Coil Reheat Coil Double

More information

Thermo Scientific Merlin Recirculating Chillers

Thermo Scientific Merlin Recirculating Chillers Thermo Scientific Merlin Recirculating Chillers Powerful cooling in a reliable and compact design Thermo Scientific Merlin Recirculating Chillers Thermo Scientific Merlin recirculating chillers are ideal

More information

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist Agilent Site Preparation InfinityLab Checklist LC Series Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification

More information

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

August  BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19 PATCH PANEL - 24x STP CAT6A PORTS 19 BLANK PATCH PANEL FOR STP KEYSTONE JACKS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS WITH EXTRA LONG STRAIN RELIEF BAR The 24-port blank patch panel is designed to use with STP keystone jacks. It can hold up to 24 RJ45 keystone jacks. It features

More information

GUARD BAGAŽO TIKRINIMO VARTAI

GUARD BAGAŽO TIKRINIMO VARTAI GUARD BAGAŽO TIKRINIMO VARTAI Eil. Nr. 1. XJ5030 Aprašymas Suitable for all areas where small suitcases and packages are allowed to be inserted in The highest penetration level to the steel in its class

More information

AristoMig U320w 208/230/400/460/475/500 V 3~ 50/60 Hz With cooling unit and central connection

AristoMig U320w 208/230/400/460/475/500 V 3~ 50/60 Hz With cooling unit and central connection Spare parts list Edition 060727 Valid for serial no. 310 -xxx -xxx, 445 -xxx -xxx, 620 -xxx -xxx The AristoMig 450 power source is renamed: New name Old name Mig 4500i AristoMig 450 Mig U4500i AristoMig

More information

PLANNING GUIDE VENTILATION

PLANNING GUIDE VENTILATION PLANNING GUIDE VENTILATION VENTILATION QUICK REFERENCE CHART Quick Reference Chart for Recommended Ventilation Based On Cooking System Updraft Ventilation Options 1 Downdraft Ventilation Options 2 Cook

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating #DEALER_LOGO P660-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 600 660 kw 480 528 kva kw Ratings at 0.8 power factor. Please refer to the

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating #DEALER_LOGO P400-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 350 400 kw 280 320 kva kw Ratings at 0.8 power factor. Please refer to the

More information

INSTALLATION AND OPERATION M

INSTALLATION AND OPERATION M INSTALLATION AND OPERATION M RUBYSTAR INSTALLATION AND OPERATION MANUAL Safety Instructions : Only authorised installers should install and or replace Rubystar inverters. Ensure that all electrical installations

More information

Multi-functional safety relay modules PROTECT SRB-E

Multi-functional safety relay modules PROTECT SRB-E Multi-functional safety relay modules PROTECT SRB-E PROTECT SRB-E The configurable User-friendly Up to 16 different applications can be selected Monitoring of all conventional safety switchgear Safety

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - P220-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 200 220 kw 160 176 kva - - kw - - Ratings at 0.8 power factor. Please refer to the output ratings

More information

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h Horizontal Multistage Pumps 50 Hz Stainless Steel 3-9 m3/h Model Number Explanation Example: 3AMH2B-51 3 = m 3 /h AMH = Series 2 = # of Stages

More information

Product catalogue 2008

Product catalogue 2008 Product catalogue 2008 welding, cutting and more... www.kemper.co.uk Extraction and filter units Design of the filter unit... 71 Intelligent filtration system...... 72 Extraction and filter units in detail.....

More information

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B ) SMARTSCAN 8000 PLUS LIGHT CURTAIN 1 Unpacking 8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/0160306 CD206B160306 ) Remove all packaging material and retain it Locate and keep the delivery

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - P165-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 150 165 kw 120 132 kva 168.8 187.5 kw 135 150 Ratings at 0.8 power factor. Please refer to the

More information

Linear flow control with actuator IFC

Linear flow control with actuator IFC Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20

More information

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating - P88-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 80 88 kw 64 70.4 kva 90 100 kw 72 80 Ratings at 0.8 power factor. Please refer to the output ratings

More information

All the energy of your home, in an App!

All the energy of your home, in an App! All the energy of your home, in an App! The smart home system for managing wireless thermostats energy meters smart sockets Rialto, simplicity with total comfort Simple installation Simple configuration

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION (FIBER OPTIC SPLICE CLOSURE) Model Spec. No. Distribution Depts. VSOF-BS403A SJP-0609-403A-01A/SD Quality Assurance Team Manufacturing Division Sales Division Management Division

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 150 165 kw 120 132 kva kw Ratings at 0.8 power factor. Please refer to the output ratings technical

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION OCTALUMINA 120: PARTS LIST AND TECHNICAL INFORMATION HIGH POWER LEDS INNER CORNER LABELED FRAME MOUNTED POWER SUPPLY UNIT EASY PLUG-IN CONNECTION BRACING TECHNIQUE CABLE OUTLET AT THE BOTTOM SYSTEM PACKAGING

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - P150-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 135 150 kw 108 120 kva 150 165 kw 120 132 Ratings at 0.8 power factor. Please refer to the output

More information