Electronic GPS Dropsonde System Installation. Electrical Loads Analysis Report: ELA-AVAPS-100
|
|
- Mercy Conley
- 6 years ago
- Views:
Transcription
1 National enter for tmospheric Research lectronic GPS ropsonde System Installation lectrical Loads nalysis Report: L-VPS-100 NS Gulfstream V ircraft, SN 677 Revision: (initial release) ate: 25 October 2005 National enter for tmospheric Research Research Technology acility 3450 Mitchell Lane oulder, olorado Prepared y: Terry Hock ngineer National enter for tmospheric Research 2005 University orporation for tmospheric Research isclosure of information contained herein may only be made to UR or personnel and/or esignees to support this certification effort. isclosure to other persons requires the express written consent of UR Legal ounsel. VPS lec load analy Rev.doc
2 Report L-VPS-100 Rev, Initial release ii lectronic GPS ropsonde System Rack Installation lectrical Loads nalysis Report: L-VPS-100 Revision Revision ate escription Pages pproved ate 25 Oct 05 Initial Release ll UR onfidential and Proprietary Information
3 Report L-VPS-100 Rev, Initial release iii NR ropsonde System lectrical Loads nalysis NS Gulfstream V ircraft, SN 677 TL O ONTNTS 1. INTROUTION SRIPTION RSRH SYSTM RSRH QUIPMNT IRUIT PROTTION LO NLYSIS ONLUSION...3 LIST O TLS Table 1 ropsonde quipment List...2 Table 2 ircuit reaker ata...2 Table 3 Power Load Summary...3 LIST O IGURS igure 1 lock diagram of power distribuiton for HIPR ropsonde Instrument...4 UR onfidential and Proprietary Information
4 Report L-VPS-100 Page 1 of 4 Rev 1. Introduction NR is developing main cabin equipment (M) racks to support atmospheric research equipment installations on the National Science oundation (NS) GV aircraft, SN677, under ST project number ST3285-T through the OT- enver O. Research power wiring was previously installed by Lockheed Martin ircraft ompany IW ST ST03056T. Research equipment will not interface with existing aircraft systems, nor will the equipment provide information to the flight crew to assist them with operation of the aircraft. Therefore, (Guidance for the Installation of Miscellaneous, Non-required lectrical quipment) will be utilized to show compliance with the applicable regulations of 14 R Part 25. This report will present the data for the electrical load analysis of the ropsonde Instrumentation rack. This report is for the electrical load analysis for the ropsonde System atmospheric instrumentation equipment installed in an instrumentation rack in the main cabin area. Items installed in the rack are ommercial Off The Shelf (OTS) equipment. There are four items which use aircraft power; 1) P Rack Mount omputer, 2) L lat Panel Monitor, 3) Telemetry chassis and 4) 28 volt Power Supply. ll equipment in the ropsonde instrumentation rack does not interface with existing aircraft systems, nor do they provide information to the flight crew to assist them with operation of the aircraft. Therefore, the miscellaneous, non-required electrical equipment and the guidance of have been utilized. 2. escription 2.1. Research System The research electrical system is designed to provide 40KV of 115 V 400HZ 3 phase power continuously from the two Integrated rive Generators (IGs) for research applications. Twenty KV from each IG is allocated for Mission power. The aircraft uses frequency converters located in the Main Power istribution ox (MP) to convert the 400 HZ to 21KV of 110 V 60 HZ 1 Phase as supplied by the manufacturer. Research power distribution and controls are located in the MP as supplied by the manufacturer. The maximum allowable continuous electrical load for each power source is 20 amps Research quipment The ropsonde system consists of the following equipment: ropsonde instrumentation rack using 115 V 60 amps. The unit is protected by the existing #330311, a 20 amp breaker located in the MP. Table 1 lists the individual components contained in the dropsonde instrument rack. Several of the units are protected by an independent circuit breakers, see table 2. ropwindsonde Launcher ssembly, manufactured by eromet/l3 ommunications Inc., model number The unit is powered by 28 Vdc from the ropsonde instrumentation rack. The wiring UR onfidential and Proprietary Information
5 Report L-VPS-100 Page 2 of 4 Rev harness between the instrumentation rack and launch tube is protected by a 20 amp circuit breaker located in the ropsonde instrument rack. UH ircraft blade antenna, Manufactured by Sensor Systems Inc., model number S This is a passive device and does not consume power. The ropsonde research instrumentation rack consists of the following commercial off the shelf (OTS) equipment: listed in Table 1 Table 1 ropsonde quipment List Item escription Manufacture Model Input Voltage 1 P omputer PS 2USP43 120V 60Hz 2 L Monitor Interlogic Industries R19X-SH 120V 60Hz 3 Telemetry hassis/ooling an NR VPS hassis 120V 60Hz 4 28Vdc Power Supply Vicor VP V 60Hz 5 Launch tube control Panel NR wg No Vdc VPS Keyboard yber Research OIX 1910-P N 7 Sonde Storage box NR wg No VPS-1-3 N block diagram (wg. No. VPS ) of the and power system is included at the end of the report of the ropsonde installation. Table 2 ircuit reaker ata Item escription ircuit reaker Rating Mill-Spec Part No. 1 ooling an 2 amps MS Telemetry hassis 1 amps MS Vicor Power Supply 5 amps MS ircuit Protection The equipment rack installed is individually protected by circuit breakers or by a shared breaker installed by the manufacturer in the MP, the breaker shall not exceed 20 mps. The circuit breakers are of the same type as installed by the manufacturer as original equipment Load nalysis elow in table 1 is a list of all devices in the ropsonde Instrumentation rack that is power by the aircraft 110 V 60Hz power system. The equipment has built in circuit breaker protection for each individual item listed in table 1. The maximum total current load under any condition is 11.7 amps. UR onfidential and Proprietary Information
6 Report L-VPS-100 Page 3 of 4 Rev Item escription Power able Type 1 omputer 3-wire 16 gauge 2 Monitor 3-wire 16gauge 3 Telemetry hassis/ ooling an 4 Vicor Power Supply Table 3 Power Load Summary Tabulation of power values Power 60 Hz for all units listed 3-wire 16 gauge 3-wire 16 gauge verage urrent (mps) Peak urrent (mps) Power Not to xceed (Watts) Unit ircuit reaker (mps) None None Total 2.0 mps 5.9 mps 1000 Watts 7 mps The maximum electrical load current at 120V 60HZ of the ropsonde Instrument rack is 5.9 amps. This load allows for a safety margin of 14.1 amps (or 70.5 %) from the 20 amp circuit for the M. 3. onclusion The basic research rack system as installed by NR is a stand alone independent system that interfaces to the Lockheed Martin ircraft enter as part of ST number ST03056T research electrical system. This research power distribution system incorporates automatic load shedding and a cockpit kill switch for the research power system. Independent circuit breakers protect all of the rack installed equipment and are of the type supplied as original equipment by the manufacturer. The system loads cannot exceed 20 amps per circuit. ll the circuit breakers are accessible to the flight crew at the Main Power istribution ox. The basic research systems do not interface with existing aircraft systems, nor do they provide information to the flight crew to assist them with operation of the aircraft. Therefore, all basic research system equipment can be considered miscellaneous, non-required electrical equipment and the guidance of has been utilized. UR onfidential and Proprietary Information
7 Report L-VPS-100 Page 4 of 4 Rev igure 1 lock diagram of power distribution for HIPR ropsonde Instrument UR onfidential and Proprietary Information
8 Main Power istribution ox (xisting) 60 Hz reakout Power ox RV. SRIPTION T Y Initial Release 9/2/05 TH Right abin SPR 120 V 60 HZ reaker "" 20 mp V 60 Hz 120 V 60 Hz 120 V 60 Hz POWR NOT TO X 350W PS omputer Model No. 2USP V 60 Hz NR wg. No V 60 Hz POWR NOT TO X 50W L Monitor Model No. R19X-SH POWR NOT TO X 100W 2.0 amp P/N: MS NR ropsonde Telemetry an Unit 120 V 60 Hz 1.0 amp P/N: MS NR ropsonde Telemetry hassis POWR NOT TO X 700W POWR NOT TO X 450W 5.0 amp P/N: MS Power Supply 28Vdc Model No. Vicor VP Vdc ropwindsonde Launcher ssembly Part No R. L SRIPTION Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge NR wg. No. 677VPS VPS VPS VPS VPS-3-02 Power 2-wire 16 gauge, 3-wire 22 gauge 677VPS-3-05 opyright 2005 University orporations for tmospheric Research, ll rights reserved. ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 9/2/05 National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O HIPR ropsonde Power istribution lock iagram SIZ ile SM Name: NO WG NO RV HIPR L iagram 677VPS Rev SL 1 : 1 SHT 1 O 1
9
10
11
12
13
14
15
16
17 ' ' ' ' ' ' '' ' ' / %=- " / /5%4,! '' / ' : / 9: 9: 9 / 9:' : / 9: ' ' 9:' 9: ' / 9: ' : / : 9 9 / " /5%4, #4#< / /5%4, )#0 #&8, %*&=3,) 9 / %=-! &8,)5##) / /: 9: /9: ' 9: /9:' : 5,>*.0<,&4.66*005.,8+143,*6,) 3,?#)$%)8)#*4,.6?#)#&,@%&4,&&%=%+5,/(' 43,/=%+5,/(2#,64#43,//5%4, %&843,%?4)#*4,.6?#)%=#&4)#5=%+5,=#&6.6.4.&2#? 43),,@.5:: (::4$#@.5:: (:: %&8#&,@=%+5,/('::' /9 : 9 :' ' 9: ' /9: ' ; '! #$%& '('(' " )$.& '((' ")*+,- '((' 6,5##) /%663)#*23 / /! #01).234'' 5).2346),6,)7,8
18 Main Power istribution ox (xisting) 60 Hz reakout Power ox RV. SRIPTION T Y Initial Release 9/2/05 TH Right abin SPR 120 V 60 HZ reaker "" 20 mp V 60 Hz 120 V 60 Hz 120 V 60 Hz POWR NOT TO X 350W PS omputer Model No. 2USP V 60 Hz NR wg. No V 60 Hz POWR NOT TO X 50W L Monitor Model No. R19X-SH POWR NOT TO X 100W 2.0 amp P/N: MS NR ropsonde Telemetry an Unit 120 V 60 Hz 1.0 amp P/N: MS NR ropsonde Telemetry hassis POWR NOT TO X 700W POWR NOT TO X 450W 5.0 amp P/N: MS Power Supply 28Vdc Model No. Vicor VP Vdc ropwindsonde Launcher ssembly Part No R. L SRIPTION Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge NR wg. No. 677VPS VPS VPS VPS VPS-3-02 Power 2-wire 16 gauge, 3-wire 22 gauge 677VPS-3-05 opyright 2005 University orporations for tmospheric Research, ll rights reserved. ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 9/2/05 National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O HIPR ropsonde Power istribution lock iagram SIZ ile SM Name: NO WG NO RV HIPR L iagram 677VPS Rev SL 1 : 1 SHT 1 O 1
19 To: Telemetry hassis RV. SRIPTION T Y Initial Release 10/19/05 TH P1: RVR/PTU UR #1 P5: MWG # Label I: P/SRIL/ Label I: P/SRIL/ P2: RVR/PTU UR #2-9 Label I: P/SRIL/ omputer Signal able P6: MWG #2-9 Label I: P/SRIL/ Male P3: RVR/PTU UR #3-9 Label I: P/SRIL/ P7: MWG #3-9 Label I: P/SRIL/ P4: RVR/PTU UR #4 P8: MWG # Label I: P/SRIL/ Label I: P/SRIL/ To: omputer -78 Port (#1 Lower onnector) 39" R Qty SRIPTION PRT NO. MNUTUR 2 Video omputer able WhyteHaus ables opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. omputer Octopus Serial able to Telemetry hassis NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-14 SL 1 : 1 SHT 1 O 2
20 To: Telemetry hassis RV. SRIPTION T Y Initial Release 10/19/05 TH P9: Telemetry Log Rcvr -9 Label I: P/SRIL/ P10: Sonde Interface -9 Label I: P/SRIL/ P105: MWG SK MO #1-9 Label I: P/SRIL/ omputer Signal able P106: MWG SK MO #2-9 Label I: P/SRIL/ Male P107: MWG SK MO #3-9 Label I: P/SRIL/ P108: MWG SK MO #4-9 Label I: P/SRIL/ Null Modem (M9 male) Null Modem (M9 male) -9-9 Label I: P/SRIL/ Label I: P/SRIL/ To: omputer -78 Port (#2 Upper onnector) 39" opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. omputer Octopus Serial able to Telemetry hassis NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-14 SL 1 : 1 SHT 2 O 2
21 RV. SRIPTION T Y Initial Release 10/19/05 TH To: omputer Keyboard Plug PS-2 Male Pink Label I: P/K&MOUS Male omputer Signal able To: omputer Mouse Plug PS-2 Male Green 42" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 Keyboard/Mouse omputer able/keyboard U-5K Ikeu opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. Keyboard/Mouse able NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-13 SL 1 : 1 SHT 1 O 1
22 RV. SRIPTION T Y Initial Release 10/19/05 TH Label I: MONITOR/VIO Male -15 Male To: omputer Video Port omputer Signal able To: Monitor Video Port 60" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 Video omputer able VNPS MM lack ox Network Services. opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. omputer Video Monitor able NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-12 SL 1 : 1 SHT 1 O 1
23 RV. SRIPTION T Y Initial Release 10/19/05 TH 120V POWR PLUG Label I: MONITOR/120V-3-11 HOT GROUN RTURN R LK WHIT Plug PLUG SI VIW NOT: SHIL NOT US ttaches To: Monitor ttaches To: Power Terminal Strip 54" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, Power / Plug, Hospital grade, 15/125V HL8215 Hubbell 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, POWR PLUG / 3-circuit SHURTR opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, Monitor NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-11 SL 1 : 1 SHT 1 O 1
24 RV. SRIPTION T Y Initial Release 10/19/05 TH R SM onnector Label I: LNHR/GPS-3-10 R SM onnector ttaches To: GPS Power ivider ttaches To: GPS ntenna 12.5" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 2 SM R ONNTORS P WIR & L 1 50 ohm OX S44191 P WIR & L opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde GPS R able, Sonde Storage ox NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV HIPR L iagram Rev 677VPS-3-10 SL 1 : 1 SHT 1 O 1
25 RV. SRIPTION T Y Initial Release 10/19/05 TH R TN onnector Label I: HSSIS/GPS-3-09 R TN onnector 25.75" ttaches To: Sonde Storage ox ttaches To: Telemetry hassis Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 2 TN R ONNTOR P WIR & L 1 50 ohm OX S44191 P WIR & L opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde GPS R L, Sonde Storage ox to Telemetry hassis NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-09 SL 1 : 1 SHT 1 O 1
26 RV. SRIPTION T Y Initial Release 10/19/05 TH 120V POWR PLUG Label I: P/120V-3-08 HOT GROUN RTURN R LK WHIT Plug PLUG SI VIW NOT: SHIL NOT US ttach To: omputer ttach To: Power Terminal Strip 39" R Qty SRIPTION PRT NO. MNUTUR Note: pply label I within 6" of each end and at 5' increments 1 onnector, Power / Plug, Hospital grade, 15/125V HL8215 Hubbell 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, POWR PLUG / 3-circuit SHURTR opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, OMPUTR NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-08 SL 1 : 1 SHT 1 O 1
27 RV. SRIPTION T Y Initial Release 10/25/05 TH MS ircular onnector ttaches to 28V Power Supply G H I J K L M N O 5" 8" 10.5" 28 V RM SOLNOI 28V 28V LUNH SOLNOI GROUN VLV OPN SIGNL Label I: LNHR/28V " 8" 10.5" G.... R S MS ircular onnector ttaches To: ropwindsonde Launcher ssembly inal length to be determined upon installation (Shall not exceed 30 ) R Qty SRIPTION PRT NO. MNUTUR Note: pply label I within 6" of each end and at 5' increments 1 onnector, MS ircular / MIL circuit MS S ITT annon 1 1 conductor 22 gauge wire, TLON WHIT M22759/1619W THRMX 1 1 conductor 16 gauge wire, TLON WHIT M22759/161619W THRMX 1 onnector, MS ircular / MIL circuit MS S ITT annon 6 rimp wire connector, covered with heat shrink tubing S18 3M opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Launcher ontrol able, to ropwindsonde Launcher ssembly NG: T. Hock 10/25/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-07 SL 1 : 1 SHT 1 O 1
28 RV. SRIPTION T Y Initial Release 10/19/05 TH R TYP "N" onnector Label I: HSSIS/400MHZ-3-06 R TYP "N" onnector ttaches To: 400 MHz UH lade ntenna ttaches To: Telemetry hassis Length to be determined upon installation (Shall not exceed 75 ) Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 2 TYP N R ONNTORS P WIR & L 1 50 ohm OX, RG-8 TYP S22089 P WIR & L opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde R OX L, UH NTNN NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-06 SL 1 : 1 SHT 1 O 1
29 Label I: LNHR/28V-3-05 RV. SRIPTION T Y Initial Release 9/7/05 TH MS ircular onnector ttaches to 28V Power Supply G H I J K L M N O 28 V RM SOLNOI 28V 28V LUNH SOLNOI GROUN VLV OPN SIGNL G H I J K L M N O P Q R S MS ircular onnector ttaches to Launch ontrol Panel 55" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, MS ircular / MIL circuit MS S ITT annon 1 1 conductor 22 gauge wire, TLON WHIT M22759/1619W THRMX 1 1 conductor 16 gauge wire, TLON WHIT M22759/161619W THRMX 1 onnector, MS ircular / MIL circuit MS S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Launcher ontrol able, Launch ontrol Panel to 28V Power Supply NG: T. Hock 9/7/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-05 SL 1 : 1 SHT 1 O 1
30 RV. SRIPTION T Y Initial Release 9/7/05 TH Label I: PS/28V-3-04 MS ircular Male onnector 28 Vdc GROUN NOT: SHIL NOT US R LK MS ircular onnector ttach to 28V Power Supply, Input ttach to Launch ontrol Panel 59" R Qty SRIPTION PRT NO. MNUTUR Note: pply label I within 6" of each end and at 5' increments 1 onnector, MS ircular / MIL circuit Male S-6P ITT annon 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, MS ircular / MIL circuit S-6S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, 28 Vdc Power Supply to Launch ontrol Panel NG: T. Hock 9/7/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-04 SL 1 : 1 SHT 1 O 1
31 RV. SRIPTION T Y Initial Release 9/7/05 TH 120V POWR PLUG Label I: PS/120V-3-03 HOT GROUN RTURN R LK WHIT MS ircular onnector PLUG SI VIW NOT: SHIL NOT US ttach to 28V Power Supply, Input 13" ttach to Terminal Strip Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, Power / Plug, Hospital grade, 15/125V HL8215 Hubbell 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, MS ircular / MIL circuit S-7S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, 28 Vdc Power Supply NG: T. Hock 9/7/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-03 SL 1 : 1 SHT 1 O 1
32 RV. SRIPTION T Y Initial Release 9/7/05 TH Label I: HSSIS/120V-3-02 MS ircular Male onnector HOT GROUN RTURN R LK WHIT MS ircular onnector ttach to ooling an NOT: SHIL NOT US 13.5" ttach to Telemetry hassis Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, MS ircular / MIL circuit Male S-7P ITT annon 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, MS ircular / MIL circuit S-7S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, ooling an unit to Telemetry hassis NG: T. Hock 9/7/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-02 SL 1 : 1 SHT 1 O 1
33 RV. SRIPTION T Y Initial Release 10/19/05 TH 120V POWR PLUG Label I: NS/120V-3-01 HOT GROUN RTURN R LK WHIT MS ircular onnector PLUG SI VIW NOT: SHIL NOT US ttaches to ooling an Input ttaches to Terminal Strip 31" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, Power / Plug, Hospital grade, 15/125V HL8215 Hubbell 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, MS ircular / MIL circuit S-7S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab (OL) 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, ooling an NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-01 SL 1 : 1 SHT 1 O 1
34 RV. SRIPTION T Y Initial Release 9/2/05 TH H H G L Monitor Video Input Video Signal Power 120V 60 Hz 3-wire Input Power 120V 60 Hz 3-wire Power Strip H K Power 120V 60 Hz 3-wire R. G H I J K L M N O rawing Number 677VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS-3-15 G L P omputer Keyboard M Input Video RJ-45 Network Keyboard RS-232 Signal N I OX GPS R Power ivider To ircraft ata System OX Sonde Storage ox J OX GPS ntenna IRRT GPS R SIGNL Telemtry hassis ooling an RVR/PTU uffer Input MWG Log Rcvr Sonde Interface MWG P1 ata MWG SK emod GPS nt 400 MHz nt OX Output Input Power 120V 60 Hz 3-wire opyright 2005 University orporations for tmospheric Research, ll rights reserved. OX 400 MHz UH L NTNN National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O O ROPWINSON LUNHR ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 9/2/05 HIPR ROPSON INSTRUMNTTION SSMLY WIRING IGRM SIZ ile SM Name: NO WG NO RV VPS-2-02 SL 1 : 1 SHT 1 O
35 RV. SRIPTION T Y Initial Release 9/2/05 TH H H G LUNH ONTROL PNL G VIOR 28V SUPPLY ROPSON ISPNSR MOUNT ON RONT O INSTRUMNT RK 28 Vdc POWR SUPPLY MOUNT ON RR O INSTRUMNT RK 120V INPUT 28V OUT ONTROL PNL ISPNSR Power 120V 60 Hz 3-wire G TO ROPWINSON LUNHR SSMLY Power Strip MOUNT ON RR O INSTRUMNT RK opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 9/2/05 HIPR ropsonde ssembly Wiring iagram SIZ ile SM Name: NO WG NO RV HIPR L iagram Rev VPS-2-02 SL 1 : 1 SHT 2 O
36 RV. SRIPTION T Y Initial Release 10/26/05 TH H GPS R Signal xisting R oax H Sonde Storage ox (GPS Power ivider) H R oax wg. 677VPS Label I: GPS/LNHR-3-15 H 400 MHz R Signal H wg. 677VPS R oax I J I G 120 V 120 V ooling an wg. 677VPS-3-01 Power Label I: NS/120V-3-01 wg. 677VPS Power Label I: MONITOR/120V-3-11 wg. 677VPS Power L Monitor R oax wg. 677VPS Label I: LNHR/GPS-3-10 K Label I: HSSIS/400MHZ-3-06 Label I: HSSIS/120V-3-02 Video Signal Label I: HSSIS/GPS-3-09 wg. 677VPS I R oax H M Telemetry hassis R. G H I J K L M N O P ONNTOR TYP, SRIPTION Power Plug, 3-circuit Power, MS ONNTOR 3-PIN ML Power, MS ONNTOR 3-PIN ML Power, MS ONNTOR 6-PIN ML Power & SIGNL, MS ONNTOR 6-PIN ML Power & SIGNL, MS ONNTOR 15-PIN ML Power & SIGNL, MS ONNTOR 19-PIN ML R SIGNL, TYP N ML R ONNTOR R SIGNL, TN ML R ONNTOR R SIGNL, SM ML R ONNTOR VIO SIGNL, 15-PIN ML ONNTOR RS-232 OMPUTR SIGNL, 80-PIN ONNTOR RS-232 SIGNL, 9-PIN ML ONNTORS OMPUTR SIGNL, 15-PIN ML ONNTOR NTWORK SIGNL, 6-PIN, RJ-45 ONNTOR PSSIV GPS NT., P/N: L1RRKP-S, GPS Networking Inc. G Location: aggage compartment area wg. 677VPS Label I: MONITOR/VIO-3-12 wg. 677VPS omputer RS-232 Signal Label I: P/SRILXX-3-14 J P Passive GPS ntenna P/N. L1RRKP-S 120 V omputer Network wg. 677VPS Power Label I: P/120V-3-08 xisting Network able O P omputer K L N N wg. 677VPS omputer Signal Label I: P/K&MOUS-3-13 Keyboard ropwindsonde Launcher ssembly Part No wg. 677VPS Vdc Label I:LNHR/28V-3-07 G 120 V wg. 677VPS Power Label I: PS/120V Vdc Power Supply wg. 677VPS Vdc Label I:LNHR/28V-3-05 wg. 677VPS Vdc Launch ontrol Panel Label I: PS/28V-3-04 opyright 2005 University orporations for tmospheric Research, ll rights reserved. ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 10/26/05 National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O HIPR ropsonde Instrumentation lock Wiring iagram SIZ ile SM Name: NO WG NO RV HIPR ropsonde VPS-2-01 lock Wiring 677VPS-2-01 SL 1 : 1 SHT 1 O
37 RV. SRIPTION T Y Initial Release 10/19/05 TH R TN onnector Label I: GPS/LNHR-3-15 R SM onnector ttaches To: GPS Power ivider ttaches To: GPS ntenna Length to be determined at install Shall not exceed 30' Note: pply label I within 6" of each end and at 5' increments R P WIR & L able ssembly Part No Qty SRIPTION PRT NO. MNUTUR 1 SM R ONNTORS P WIR & L 1 50 ohm OX S44191 P WIR & L 1 TN R ONNTOR P WIR & L opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde GPS R able, Launcher GPS Reradiating ntenna NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV HIPR L iagram Rev 677VPS-3-15 SL 1 : 1 SHT 1 O 1
P2-HSI High-Speed Isolated Sinking/Sourcing Input. Connector Specifications
WARNG: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from
More informationDF64 Digital Frame Manual
S Word Int 44.1 48 96 PU Select P ctive ustom Locked S W Int 44.1 48 96 PU Select P ctive ustom Locked S Sync S Sync MI Inputs MI Inputs In In Out Out Word Sync Word Sync In 75 In 75 Out Out irewire irewire
More informationFD70CV-M-C-9. Installation and Operation Manual. 7 NVG Compatible LCD. Revision Date: 06/16/2017 Page 1 of 12. Rev: A
Page 1 of 12 Installation and Operation Manual FD70CV-M-C-9 7 NVG Compatible LCD Page 2 of 12 Specifications Display FD70CV-M-C-9 Panel Technology Diagonal Screen Size Native Resolution Pixel Pitch TN,
More informationO N W E I G H T S A N D
O N Standard eatures L display, (W x H) 4.6 in x 3.4 in Selectable character sizes from 0.25 in to 1.2 in 60 configurable operator prompts isplay up to four scale channels per screen with required Legal
More informationPERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE THREE-POLE, AUXILIARY CONTACTS
INH-POUND MIL-PRF-39019/6H 14 May 0 SUPERSEDING MIL-PRF-39019/6G 27 ugust 1997 PERFORMNE SPEIFITION SHEET IRUIT REKERS, MGNETI, LOW-POWER, SELED, TRIP-FREE THREE-POLE, UXILIRY ONTTS This specification
More informationP P S - M W S C A N 1 H
µ-controller-systems / HARD- & SOFTWARE-DESIGN POWER-SUPPLIES FROM MILLIWATTS TO KILOWATTS Device: PPS-MWS-3000-4500-CAN1H 06 / 2017 Page 1 / 6 S w i t c h i n g M o d e P o w e r S u p p l y f o r M a
More informationModel /29S RF Splitter
Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary
More informationRSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable
RSSL1:1-KuXER Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System Outdoor Unit (ODU) Waveguide Switch & Status LNB 1 Coax cable Interface Terminal LNB 2 Indoor Unit Outdoor Unit Indoor
More informationZDC RF Coax Connector Series 50 & 75 Ohm
CONTACTORS CONNECTORS WIRE & CABLE EMI/RFI FILTERS CIRCUIT BREAKERS HARNESSING & PROTECTION IDENTIFICATIO I/RFI FILTERS CIRCUIT BREAKERS HARNESSING & PROTECTION IDENTIFICATION & LABELING PCB & CABLE ASSEMBLIES
More informationFD171CV-C-4. Installation and Operation Manual. 17 HDSDI Special Mission Quad Monitor. Revision Date: 01/11/2017 Page 1 of 14.
Page 1 of 14 Installation and Operation Manual FD171CV-C-4 17 HDSDI Special Mission Quad Monitor Page 2 of 14 Table of Contents General Information...3 Front View...3 Additional Information...3 Specifications...4
More informationsupported Digital Multi Switcher MSD-6208
RoHS 4K@30 supported igital Multi Switcher Ver.1.1.0 (180529) The IK is a high-performance digital multi switcher with a scan converter and up to 8 inputs and 8 outputs. For video input, 8 digital and
More informationMASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz
Mobile Communications MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO
More informationMONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE
More informationsupported Digital Multi Switcher MSD-6203
RoHS 4K@30 supported igital Multi Switcher Ver.1.3.0 (180907) The IK is a high-performance digital multi switcher with a scan converter and up to 8 inputs and 3 outputs. For video input, 8 digital and
More informationInstallation Guide. PowerLogic LVCT. 1 VAC and.333 VAC Current Transducers
Installation Guide PowerLogic LVT 1 V and.333 V urrent Transducers ontents Installation Overview... 2 Specifications... 2 Introduction... 3 escription... 3 Ratings... 3 imensions... 4 NGR HZR O LTRI SHOK,
More information3M Sensored Termination (15 kv) QX-T15I-vi1-E
3M Sensored Termination () QX-T15I-vi1-E Data Sheet May 2016 Kit Contents: Each kit contains sufficient quantities of the following materials to make three single-phase terminations. 31" (REF) One piece
More informationFD171CV-C-1. Installation and Operation Manual. 17 LCD Monitor. Revision Date: 01/11/2017 Page 1 of 16. Rev: C. Document Number: MAN FD171CV-C-1
MAN FD171V--1 Page 1 of 16 Installation and Operation Manual FD171V--1 17 LD Monitor 2017 FDS Avionics orp. TEHNIAL SUPPORT MAN FD171V--1 Page 2 of 16 Table of ontents General Information...3 Front View...3
More informationInstruction Manual Model BlockUpconverter
Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationMAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams
MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic
More informationInstruction Manual Model # Block Upconverter
Instruction Manual Model 2115-278# Block Upconverter August 2018, Rev. A MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationFD70CV-M-C-8. Installation and Operation Manual. 7 Widescreen LCD /Standard Arm. Revision Date: 05/17/2017 Page 1 of 14. Rev: A
MN FD70CV-M-C-8 Page 1 of 14 Installation and Operation Manual FD70CV-M-C-8 7 Widescreen LCD /Standard rm MN FD70CV-M-C-8 Page 2 of 14 Specifications Display FD70CV-M-C-8 Panel Technology Diagonal Screen
More informationACTIVE IF SPLITTER/COMBINER UHP-IFS
ACTIVE IF SPLITTER/COMBINER UHP-IFS GENERAL DESCRIPTION AND INSTALLATION GUIDE DOCUMENT RELEASE 2 [UHP.IFS.2.EN] JUNE 2016 CONTENT Acronyms and Abbreviations... 4 Introduction... 5 Required level of qualification...
More informationopengear OPG-1L 50 MHz-2.3 GHz
MODEL opengear OPG-1L 50 MHz-2.3 GHz RF FIBER OPTIC LINK EMCORE s opengear OPG-1L s are optimized to perform in the 50 MHz to 2.3 GHz frequency range providing transparent signal transport for satellite
More information6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features
Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page
More informationKu-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN
BRK-1000 Series Ku-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon
More informationTECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD
TECHNICAL SUPPORT 678-867-6717, or www.flightdisplay.com FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD FD151CV-LP 15.1" Low Profile LCD 2006 Flight Display Systems. All Rights Reserved.
More informationE3/DS3 Fibre Extender
User Manual E3/DS3 Fibre Extender Black Box Network Services 464 Basingstoke Road, Reading, Berkshire, RG2 0BG Tech: 0118 965 6000 www.blackbox.co.uk CONTENTS 1 Introduction 1 1.1 About the products 1
More informationLEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1200-75 Amplifier August 2012, Rev. A LEVEL ADJUST POWER MODEL 1200 AMPLIFIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary to Cross
More informationTelemetry Receiver Installation Guide
BBV Telemetry Receiver Installation Guide Models covered Rx200 Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323
More informationLEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1200-07 Amplifier September 2010 Rev A MONITOR J1 LEVEL ADJUST POWER MODEL 1200 AMPLIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary
More informationActive UTP Transceiver Hub Installation Guide
Active UTP Transceiver Hub Installation Guide Models Include: HubWayEX16 - Sixteen (16) Channels - Thirty-two (32) Channels Rev. 011810 More than just power. TM Overview: Altronix HubWayEX16/EX32 Active
More informationUser Manual. HDBaseT Receiver CMHDBTBRX. Front View Panduit Dr, Tinley Park, IL (708)
User Manual HDBaseT Receiver CMHDBTBRX Front View 18900 Panduit Dr, Tinley Park, IL 60487 (708) 532-1800 Back View TABLE OF CONTENTS Introduction 2 Features 3 Package Contents 3 Technical Specifications
More informationFD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:
Page 1 of 16 FD104CV Installation and Operation Manual 10.4 LCD TCHNICAL SUPPORT 678-867-6717, or www.flightdisplay.com Page 2 of 16 FD104CV 10.4 LCD 2006 Flight Display Systems. All Rights Reserved. Flight
More informationCamera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"
The Telemetrics Coax/Fiber Link is an affordable camera control system with increased operating distance. Using frequency multiplexing the following signals are transmitted over a single coaxial cable:
More informationMS2540 Current Loop Receiver with RS485 Communication
MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:
More informationCLT-353R & CLT-353L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.1, 4/19/2013 preliminary
CLT-353R & CLT-353L CAMERA LINK TRANSLATOR User s Manual Document # 201201, Rev 0.1, 4/19/2013 preliminary Vivid Engineering 159 Memorial Drive, Suite F Shrewsbury, MA 01545 Phone 508.842.0165 Fax 508.842.8930
More informationSIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz
SIR-4002 MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz WIDE FREQUENCY RANGE: 0.5 26.5 GHz FEATURES Advanced Front Panel Alphanumeric Display High Dynamic Range: In band Input IP3 > 0 dbm, NF< 15 db DSP
More informationSIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO
SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO 18 GHz WIDE FREQUENCY RANGE: 0.5-18 GHz FEATURES High Dynamic Range Fast Switching Synthesizer with 10 Hz Tuning Resolution Excellent Phase Noise
More informationMENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2016-1250 Downconverter May 2009 Rev A F=2501.750 G=+25.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained
More informationTechnical Description
irig Multi Band Digital Receiver System Technical Description Page 1 FEATURES irig Multi Band Digital Receiver System The irig range of telemetry products are the result of a multi year research and development
More informationSIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO
SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO 26.5 GHz WIDE FREQUENCY RANGE: 0.5-26.5 GHz FEATURES High Dynamic Range Fast Switching Synthesizer with 10 Hz Tuning Resolution Excellent Phase
More informationCAT EXT-CAT USER MANUAL
CAT5 8000 EXT-CAT5-8000 USER MANUAL www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday
More information11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS
11 GHz MDD FIBER OPTIC LINK FEATURES Small size Bandwidth to 11 GHz Plug-in optical connector No external control circuits required Transimpedance amplifier in both transmitter and receiver Custom transmitter
More informationE3/DS3 Tap. 6xBNC Type
E3/DS3 Tap 6xBNC Type CUSTOMER SUPPORT INFORMATION To order or for a technical information support: Phone: +33 3 88 10 18 30 or Fax: +33 3 88 10 18 35 Mail order: COMCRAFT 2, rue de la Mairie 67203 Oberschaeffolsheim
More information% & ) ANSI Accredited Program
PROUT RTIITION Pilot Operated Water onditioning & Purification Valves omposite ody to 2-WY pplications Water purification, conditioning and distribution in commercial/ industrial markets with reverse osmosis
More informationMultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire
MultiMac SM Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Features of the MultiMac SM Electronics Simultaneous Coil and/or Rotary Probe operation Differential
More informationCONNECTORS. Simple steps to guide you in using this catalogue. Applications. Options. Ordering Codes BNC 75Ω RF CONNECTORS
NC 75Ω RF CONNCTORS NC 75Ω RF CONNCTORS Within the internationally standardised NC mating face dimensions, a perfect 75 ohm characteristic impedance cannot be realised. However, at frequencies up to 1000
More informationChurch Layout Medium Advanced
Specifier Product Information Church Layout Medium Advanced System Summary This summary is intended to explain, in general terms, some of the possible uses and reasons for having the recommended equipment
More informationFDSDIVCS-4-5 FDSDIVCS-4-10
Revision ate: Page 1 of 18 Installation and Operation Manual FSIVCS-4-5 FSIVCS-4-10 SI Video Crosspoint Switch Revision ate: Page 2 of 18 FSIVCS-4-5 FSIVCS-4-10 SI Video Crosspoint Switch 2014 Flight isplay
More informationModular Block Converter Systems
Modular Block Converter Systems The Modular Block Converter System eliminates system downtime and maximizes ease of repair by providing fully modular systems for up conversion or down conversion. Critical
More informationSpecifications MAV Series Matrix Switchers
Specifications MAV Series Matrix Switchers Video composite video and S-video models Routing MAV 44 Series... 4 x 4 matrix MAV 48 Series... 4 x 8 matrix MAV 62 Series... 6 x 2 matrix MAV 84 Series... 8
More informationSpecifications MAV Series Matrix Switchers
Specifications MAV Series Matrix Switchers Video Routing MAV 62... 6 x 2 matrix MAV 84 RCA... 8 x 4 matrix MAV 128 RCA... 12 x 8 matrix MAV 168 Series... 16 x 8 matrix MAV 1616 Series... 16 x 16 matrix
More informationELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE
ELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE E0.01 FIRST FLOOR DEMOLITION E1.01 10 E2 11 12 12 G2 14 15 D1 D2 17 18 18 19 1 2 3 4 19 21 1 3 2 4 5 1 3 2 4 5 7 6 7 A2 E1 C2 A2 H1 H2 A1 E1 E2 6 8 A1 11 C1
More informationR e c e i v e r. Receiver
R e c e i v e r Receiver > Eight channels > Eight configurable inputs > Three independent zones > Integrated 7-channel amplifier with massive toroidal transformer and thermal/dc protection > AM/FM tuner
More informationSPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment
2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment
More informationPassive UTP Transceiver Hub with Integral Camera Power Installation Guide
Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat8D - Eight (8) Channels HubSat82D - HubSat8D w/eight (8) HubWayAv Balun/s for s HubSat83D - HubSat8D w/eight (8) HubWayDv
More informationKey Features and functions. General Description
Technical Specification Summary Frequency Range 470 862MHz Typ. Gain 56 db P1dB 1400 W Typ. Efficiency >40 % @ 1dBcp Analogue TV 2400 Wps Temperature Range 0 to +45C DVB 290 Wrms Max VSWR 3:1 DTV 500 Wrms
More informationKinetix Application Note
Applying 2094 LIM Modules to Multiple Loads Kinetix Application Note PURPOSE This document addresses application cases where it is desired to utilize a single 2094 LIM module to supply three phase power
More informationDigital Matrix Switcher (Scan converter output board) FDX-64
RoHS igital Matrix Switcher ( output board) FX-64 The IK FX series represent a new level of matrix switching for V systems. The FX series combine the simplicity and reliability of a fixed I/O matrix switcher
More informationMENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2584-31 Combiner May 2011, Rev. A RF MONITOR GAIN = -15 MENU MODEL 2584 COMBINER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained
More informationGeneral Description. SC Configurations
S onnectors General Description Delta S series connectors are medium-size, 50Ω impedance connectors with 11 16-24 threaded coupling and good power handling capability, particularly those connectors noted
More informationAutomatic Test System AT-S + with STAR + Technology Features
AT-S + with STAR + Technology Features AT-S + offers all the known benefits of our STAR technology, now also for AC safety power sources. It is the perfect symbiosis of CEWA GUARD and STAR technology.
More informationInstallation. SAPTF33xx-1xx in the Network. Standard Configuration
SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device
More informationI R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:
More informationPassive UTP Transceiver Hub with Integral Camera Power Installation Guide
Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat4D - Four (4) Channel Passive UTP Transceiver Hub with Integral HubSat42D - Four (4) Channel Passive UTP Transceiver includes
More informationSPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment
1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More information2014 Product Catalog
2014 Product Catalog What are the CleanStage products? CleanStage products are a toolkit for cabling your event s stage with signal and power, providing maximum time savings, operational efficiency, and
More informationFrameworx LCD Interface
Pre-Installation & Installation Manual Frameworx LCD Interface February 2012 / 57-900073-000 Frameworx LCD Interface Pre-Installation & Installation Manual February 2012 by the Brunswick Bowling and Billiards
More information4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX
4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX 1 Contents CHAPTER 1. INTRODUCTION... 2 1.1 OVERVIEW...2 1.2 FEATURE...2 1.3 APPLICATION...3
More informationFDCONV-HDSDI-D VER SW FDCONV-HDSDI-S VER SW
Page 1 of 13 Installation and Operation Manual DCONV-HDSDI-D DCONV-HDSDI-S HDSDI Converter 2017 DS Avionics Corp. 470-239-7421 or DSAvionics.com Page 2 of 13 Table of Contents General Information...3 unctionality...3
More informationFREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS
MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422 remote control
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More information12X SERIES. 12x1 Switcher. Video / Stereo-Audio or Video Only
12X SERIES 12x1 Switcher Video / StereoAudio or Video Only Instruction Manual Sigma Electronics, Inc. P.O. Box 448 1027 ommercial Ave. East Petersburg, PA 17520 (717) 5692681 Rev 1.2 (1001) REEIVG: It
More informationOPTOCORE Technology Overview. Topology and Connection Set-up. Yamaha Emulation Mode (YEM) Ring Topology
Technology Overview is a synchronous, redundant, optical ring network capable to transport audio, video, control data and word clock over extremely long distances. The large variety of modules can all
More informationSpecifications XTP CrossPoint 1600 and XTP CrossPoint 3200 Series
Specifications XTP CrossPoint 1600 and XTP CrossPoint 3200 Series Video input XTP CP 4i, XTP CP 4i DMA Number/signal type... 4 sets of proprietary twisted pair AV signals Connectors... 4 female RJ-45 per
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationFIBERX DISTRIBUTION NETWORK SOLUTIONS
IRX ISTRIUTION NTWORK SOLUTIONS INTROUTION hannell s bundled technology solutions will ensure accelerated return on investment when building and deploying passive fiber to the home (TT) networks. hannell
More informationC-Band Redundant LNB Systems
C-Band Redundant LNB Systems BRC-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon
More informationDigital Matrix Switcher (Scan converter output board) FDX-64
RoHS igital Matrix Switcher ( output board) FX-64 The IK FX series represent a new level of matrix switching for V systems. The FX series combine the simplicity and reliability of a fixed I/O matrix switcher
More informationINSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR
INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form
More informationDigital Matrix Switcher (Scan converter output board) FDX-32
RoHS igital Matrix Switcher ( output board) FX-32 The IK FX series represent a new level of matrix switching for V systems. The FX series combine the simplicity and reliability of a fixed I/O matrix switcher
More informationX-Band Redundant LNB Systems
X-Band Redundant LNB Systems BRX-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon
More informationGFT Channel Slave Generator
GFT1018 8 Channel Slave Generator Features 8 independent delay channels 1 ps time resolution < 100 ps rms jitter for optical triggered delays 1 second range Electrical or optical output Three trigger modes
More informationDigital Matrix Switcher (Scan converter output board) FDX-16
RoHS igital Matrix Switcher ( output board) FX-16 The IK FX series represent a new level of matrix switching for V systems. The FX series combine the simplicity and reliability of a fixed I/O matrix switcher
More informationMultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire
MultiMac Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Inspection Features Versatile Threshold Selection Challenging test conditions are made simple
More informationFD104CV. Installation and Operation Manual 10.4 LCD. Revision Date: 08/01/2017 Page 1 of 14. Rev: G. Document Number: MAN FD104CV
Page 1 of 14 Installation and Operation Manual FD104CV 10.4 LCD Page 2 of 14 Table of Contents eneral Information... 3 Front View... 3 Additional Information... 3 Specifications... 4 Installation Instructions...
More informationInstallation Guide. Document Revision: 1.4 Part Number: Release Date: August, 2003
Installation Guide ocument Revision: 1.4 Part Number: 840-08472-03 Release ate: ugust, 2003 uphonix, Inc. 220 Portage ve. Palo lto, alifornia 94306 Phone: 650-855-0400 ax: 650-855-0410 Web: http://www.euphonix.com
More informationSingle sensor setup with NIVEL210
Single sensor setup with NIVEL210 Essential Items: 576 198 NIVEL210 RS232 748 335 Cable, Lemo 0 power supply cable Lemo 1 802 902 Cable, Lemo 0 722 409 Power supply plus power cords 802 902 576 198 748
More informationMAP110 AC-DC Series Data Sheet
Description Single-Output Model Selection VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012
More informationHDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL
HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this manual. Keep this
More informationFD104CV-C-L/R-1. Installation and Operation Manual LCD Monitor Left/Right Arm Mount. Revision Date: 07/28/2017 Page 1 of 13.
Page 1 of 13 Installation and Operation Manual FD104CV-C-L/R-1 10.4 LCD Monitor Left/Right Arm Mount TCHNICAL SUPPORT Page 2 of 13 Table of Contents General Information... 3 Front View... 3 Additional
More informationUser s Manual. Document # , Rev 1.2, 6/12/2006
CAMERA LINK TM VIDEO SPLITTER User s Manual Document # 200205, Rev 1.2, 6/12/2006 Vivid Engineering 418 Boston Turnpike #104 Shrewsbury, MA 01545 Phone 508.842.0165 Fax 508.842.8930 www.vividengineering.com
More informationNanoCom ADS-B. Datasheet An ADS-B receiver for space applications
NanoCom ADS-B Datasheet An ADS-B receiver for space applications 1 Table of contents 1 TABLE OF CONTENTS... 2 2 CHANGELOG... 3 3 INTRODUCTION... 4 4 OVERVIEW... 4 4.1 HIGHLIGHTED FEATURES... 4 4.2 BLOCK
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationMultiView 450. Installation & Reference Guide. Preliminary. Magenta Research Ltd
Preliminary MultiView 450 Installation & Reference Guide Magenta Research Ltd 934B Federal Road, Brookfield, CT 06804 USA (203) 740-0592 FAX (203) 740-0596 www.magenta-research.com Magenta Research Ltd
More informationOCS (Oval Contact System)
S--9 OS (Oval ontact System) S IS igh ensity: wide variety of insert arrangements available atterns range from () to (), 00 Ohm differential pairs capable of delivering data transfer speeds of 0bps per
More informationUser Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708)
User Manual HDBaseT Wallplate Transmitter over Cat6/6A Front View 18900 Panduit Dr, Tinley Park, IL 60487 (708) 532-1800 Back View TABLE OF CONTENTS Introduction 2 Features 3 Package Contents 3 Technical
More informationBasic & Safe. Industrial plugs and sockets
asic & Safe Industrial plugs and sockets Screwless terminal connectors Highly reliable and safe products Easy to install thanks to clear terminal marking Resistant against vibrations and heat fluctuations
More information