Electronic GPS Dropsonde System Installation. Electrical Loads Analysis Report: ELA-AVAPS-100

Size: px
Start display at page:

Download "Electronic GPS Dropsonde System Installation. Electrical Loads Analysis Report: ELA-AVAPS-100"

Transcription

1 National enter for tmospheric Research lectronic GPS ropsonde System Installation lectrical Loads nalysis Report: L-VPS-100 NS Gulfstream V ircraft, SN 677 Revision: (initial release) ate: 25 October 2005 National enter for tmospheric Research Research Technology acility 3450 Mitchell Lane oulder, olorado Prepared y: Terry Hock ngineer National enter for tmospheric Research 2005 University orporation for tmospheric Research isclosure of information contained herein may only be made to UR or personnel and/or esignees to support this certification effort. isclosure to other persons requires the express written consent of UR Legal ounsel. VPS lec load analy Rev.doc

2 Report L-VPS-100 Rev, Initial release ii lectronic GPS ropsonde System Rack Installation lectrical Loads nalysis Report: L-VPS-100 Revision Revision ate escription Pages pproved ate 25 Oct 05 Initial Release ll UR onfidential and Proprietary Information

3 Report L-VPS-100 Rev, Initial release iii NR ropsonde System lectrical Loads nalysis NS Gulfstream V ircraft, SN 677 TL O ONTNTS 1. INTROUTION SRIPTION RSRH SYSTM RSRH QUIPMNT IRUIT PROTTION LO NLYSIS ONLUSION...3 LIST O TLS Table 1 ropsonde quipment List...2 Table 2 ircuit reaker ata...2 Table 3 Power Load Summary...3 LIST O IGURS igure 1 lock diagram of power distribuiton for HIPR ropsonde Instrument...4 UR onfidential and Proprietary Information

4 Report L-VPS-100 Page 1 of 4 Rev 1. Introduction NR is developing main cabin equipment (M) racks to support atmospheric research equipment installations on the National Science oundation (NS) GV aircraft, SN677, under ST project number ST3285-T through the OT- enver O. Research power wiring was previously installed by Lockheed Martin ircraft ompany IW ST ST03056T. Research equipment will not interface with existing aircraft systems, nor will the equipment provide information to the flight crew to assist them with operation of the aircraft. Therefore, (Guidance for the Installation of Miscellaneous, Non-required lectrical quipment) will be utilized to show compliance with the applicable regulations of 14 R Part 25. This report will present the data for the electrical load analysis of the ropsonde Instrumentation rack. This report is for the electrical load analysis for the ropsonde System atmospheric instrumentation equipment installed in an instrumentation rack in the main cabin area. Items installed in the rack are ommercial Off The Shelf (OTS) equipment. There are four items which use aircraft power; 1) P Rack Mount omputer, 2) L lat Panel Monitor, 3) Telemetry chassis and 4) 28 volt Power Supply. ll equipment in the ropsonde instrumentation rack does not interface with existing aircraft systems, nor do they provide information to the flight crew to assist them with operation of the aircraft. Therefore, the miscellaneous, non-required electrical equipment and the guidance of have been utilized. 2. escription 2.1. Research System The research electrical system is designed to provide 40KV of 115 V 400HZ 3 phase power continuously from the two Integrated rive Generators (IGs) for research applications. Twenty KV from each IG is allocated for Mission power. The aircraft uses frequency converters located in the Main Power istribution ox (MP) to convert the 400 HZ to 21KV of 110 V 60 HZ 1 Phase as supplied by the manufacturer. Research power distribution and controls are located in the MP as supplied by the manufacturer. The maximum allowable continuous electrical load for each power source is 20 amps Research quipment The ropsonde system consists of the following equipment: ropsonde instrumentation rack using 115 V 60 amps. The unit is protected by the existing #330311, a 20 amp breaker located in the MP. Table 1 lists the individual components contained in the dropsonde instrument rack. Several of the units are protected by an independent circuit breakers, see table 2. ropwindsonde Launcher ssembly, manufactured by eromet/l3 ommunications Inc., model number The unit is powered by 28 Vdc from the ropsonde instrumentation rack. The wiring UR onfidential and Proprietary Information

5 Report L-VPS-100 Page 2 of 4 Rev harness between the instrumentation rack and launch tube is protected by a 20 amp circuit breaker located in the ropsonde instrument rack. UH ircraft blade antenna, Manufactured by Sensor Systems Inc., model number S This is a passive device and does not consume power. The ropsonde research instrumentation rack consists of the following commercial off the shelf (OTS) equipment: listed in Table 1 Table 1 ropsonde quipment List Item escription Manufacture Model Input Voltage 1 P omputer PS 2USP43 120V 60Hz 2 L Monitor Interlogic Industries R19X-SH 120V 60Hz 3 Telemetry hassis/ooling an NR VPS hassis 120V 60Hz 4 28Vdc Power Supply Vicor VP V 60Hz 5 Launch tube control Panel NR wg No Vdc VPS Keyboard yber Research OIX 1910-P N 7 Sonde Storage box NR wg No VPS-1-3 N block diagram (wg. No. VPS ) of the and power system is included at the end of the report of the ropsonde installation. Table 2 ircuit reaker ata Item escription ircuit reaker Rating Mill-Spec Part No. 1 ooling an 2 amps MS Telemetry hassis 1 amps MS Vicor Power Supply 5 amps MS ircuit Protection The equipment rack installed is individually protected by circuit breakers or by a shared breaker installed by the manufacturer in the MP, the breaker shall not exceed 20 mps. The circuit breakers are of the same type as installed by the manufacturer as original equipment Load nalysis elow in table 1 is a list of all devices in the ropsonde Instrumentation rack that is power by the aircraft 110 V 60Hz power system. The equipment has built in circuit breaker protection for each individual item listed in table 1. The maximum total current load under any condition is 11.7 amps. UR onfidential and Proprietary Information

6 Report L-VPS-100 Page 3 of 4 Rev Item escription Power able Type 1 omputer 3-wire 16 gauge 2 Monitor 3-wire 16gauge 3 Telemetry hassis/ ooling an 4 Vicor Power Supply Table 3 Power Load Summary Tabulation of power values Power 60 Hz for all units listed 3-wire 16 gauge 3-wire 16 gauge verage urrent (mps) Peak urrent (mps) Power Not to xceed (Watts) Unit ircuit reaker (mps) None None Total 2.0 mps 5.9 mps 1000 Watts 7 mps The maximum electrical load current at 120V 60HZ of the ropsonde Instrument rack is 5.9 amps. This load allows for a safety margin of 14.1 amps (or 70.5 %) from the 20 amp circuit for the M. 3. onclusion The basic research rack system as installed by NR is a stand alone independent system that interfaces to the Lockheed Martin ircraft enter as part of ST number ST03056T research electrical system. This research power distribution system incorporates automatic load shedding and a cockpit kill switch for the research power system. Independent circuit breakers protect all of the rack installed equipment and are of the type supplied as original equipment by the manufacturer. The system loads cannot exceed 20 amps per circuit. ll the circuit breakers are accessible to the flight crew at the Main Power istribution ox. The basic research systems do not interface with existing aircraft systems, nor do they provide information to the flight crew to assist them with operation of the aircraft. Therefore, all basic research system equipment can be considered miscellaneous, non-required electrical equipment and the guidance of has been utilized. UR onfidential and Proprietary Information

7 Report L-VPS-100 Page 4 of 4 Rev igure 1 lock diagram of power distribution for HIPR ropsonde Instrument UR onfidential and Proprietary Information

8 Main Power istribution ox (xisting) 60 Hz reakout Power ox RV. SRIPTION T Y Initial Release 9/2/05 TH Right abin SPR 120 V 60 HZ reaker "" 20 mp V 60 Hz 120 V 60 Hz 120 V 60 Hz POWR NOT TO X 350W PS omputer Model No. 2USP V 60 Hz NR wg. No V 60 Hz POWR NOT TO X 50W L Monitor Model No. R19X-SH POWR NOT TO X 100W 2.0 amp P/N: MS NR ropsonde Telemetry an Unit 120 V 60 Hz 1.0 amp P/N: MS NR ropsonde Telemetry hassis POWR NOT TO X 700W POWR NOT TO X 450W 5.0 amp P/N: MS Power Supply 28Vdc Model No. Vicor VP Vdc ropwindsonde Launcher ssembly Part No R. L SRIPTION Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge NR wg. No. 677VPS VPS VPS VPS VPS-3-02 Power 2-wire 16 gauge, 3-wire 22 gauge 677VPS-3-05 opyright 2005 University orporations for tmospheric Research, ll rights reserved. ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 9/2/05 National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O HIPR ropsonde Power istribution lock iagram SIZ ile SM Name: NO WG NO RV HIPR L iagram 677VPS Rev SL 1 : 1 SHT 1 O 1

9

10

11

12

13

14

15

16

17 ' ' ' ' ' ' '' ' ' / %=- " / /5%4,! '' / ' : / 9: 9: 9 / 9:' : / 9: ' ' 9:' 9: ' / 9: ' : / : 9 9 / " /5%4, #4#< / /5%4, )#0 #&8, %*&=3,) 9 / %=-! &8,)5##) / /: 9: /9: ' 9: /9:' : 5,>*.0<,&4.66*005.,8+143,*6,) 3,?#)$%)8)#*4,.6?#)#&,@%&4,&&%=%+5,/(' 43,/=%+5,/(2#,64#43,//5%4, %&843,%?4)#*4,.6?#)%=#&4)#5=%+5,=#&6.6.4.&2#? 43),,@.5:: (::4$#@.5:: (:: %&8#&,@=%+5,/('::' /9 : 9 :' ' 9: ' /9: ' ; '! #$%& '('(' " )$.& '((' ")*+,- '((' 6,5##) /%663)#*23 / /! #01).234'' 5).2346),6,)7,8

18 Main Power istribution ox (xisting) 60 Hz reakout Power ox RV. SRIPTION T Y Initial Release 9/2/05 TH Right abin SPR 120 V 60 HZ reaker "" 20 mp V 60 Hz 120 V 60 Hz 120 V 60 Hz POWR NOT TO X 350W PS omputer Model No. 2USP V 60 Hz NR wg. No V 60 Hz POWR NOT TO X 50W L Monitor Model No. R19X-SH POWR NOT TO X 100W 2.0 amp P/N: MS NR ropsonde Telemetry an Unit 120 V 60 Hz 1.0 amp P/N: MS NR ropsonde Telemetry hassis POWR NOT TO X 700W POWR NOT TO X 450W 5.0 amp P/N: MS Power Supply 28Vdc Model No. Vicor VP Vdc ropwindsonde Launcher ssembly Part No R. L SRIPTION Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge Power 3-wire 16 gauge NR wg. No. 677VPS VPS VPS VPS VPS-3-02 Power 2-wire 16 gauge, 3-wire 22 gauge 677VPS-3-05 opyright 2005 University orporations for tmospheric Research, ll rights reserved. ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 9/2/05 National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O HIPR ropsonde Power istribution lock iagram SIZ ile SM Name: NO WG NO RV HIPR L iagram 677VPS Rev SL 1 : 1 SHT 1 O 1

19 To: Telemetry hassis RV. SRIPTION T Y Initial Release 10/19/05 TH P1: RVR/PTU UR #1 P5: MWG # Label I: P/SRIL/ Label I: P/SRIL/ P2: RVR/PTU UR #2-9 Label I: P/SRIL/ omputer Signal able P6: MWG #2-9 Label I: P/SRIL/ Male P3: RVR/PTU UR #3-9 Label I: P/SRIL/ P7: MWG #3-9 Label I: P/SRIL/ P4: RVR/PTU UR #4 P8: MWG # Label I: P/SRIL/ Label I: P/SRIL/ To: omputer -78 Port (#1 Lower onnector) 39" R Qty SRIPTION PRT NO. MNUTUR 2 Video omputer able WhyteHaus ables opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. omputer Octopus Serial able to Telemetry hassis NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-14 SL 1 : 1 SHT 1 O 2

20 To: Telemetry hassis RV. SRIPTION T Y Initial Release 10/19/05 TH P9: Telemetry Log Rcvr -9 Label I: P/SRIL/ P10: Sonde Interface -9 Label I: P/SRIL/ P105: MWG SK MO #1-9 Label I: P/SRIL/ omputer Signal able P106: MWG SK MO #2-9 Label I: P/SRIL/ Male P107: MWG SK MO #3-9 Label I: P/SRIL/ P108: MWG SK MO #4-9 Label I: P/SRIL/ Null Modem (M9 male) Null Modem (M9 male) -9-9 Label I: P/SRIL/ Label I: P/SRIL/ To: omputer -78 Port (#2 Upper onnector) 39" opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. omputer Octopus Serial able to Telemetry hassis NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-14 SL 1 : 1 SHT 2 O 2

21 RV. SRIPTION T Y Initial Release 10/19/05 TH To: omputer Keyboard Plug PS-2 Male Pink Label I: P/K&MOUS Male omputer Signal able To: omputer Mouse Plug PS-2 Male Green 42" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 Keyboard/Mouse omputer able/keyboard U-5K Ikeu opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. Keyboard/Mouse able NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-13 SL 1 : 1 SHT 1 O 1

22 RV. SRIPTION T Y Initial Release 10/19/05 TH Label I: MONITOR/VIO Male -15 Male To: omputer Video Port omputer Signal able To: Monitor Video Port 60" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 Video omputer able VNPS MM lack ox Network Services. opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. omputer Video Monitor able NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-12 SL 1 : 1 SHT 1 O 1

23 RV. SRIPTION T Y Initial Release 10/19/05 TH 120V POWR PLUG Label I: MONITOR/120V-3-11 HOT GROUN RTURN R LK WHIT Plug PLUG SI VIW NOT: SHIL NOT US ttaches To: Monitor ttaches To: Power Terminal Strip 54" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, Power / Plug, Hospital grade, 15/125V HL8215 Hubbell 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, POWR PLUG / 3-circuit SHURTR opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, Monitor NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-11 SL 1 : 1 SHT 1 O 1

24 RV. SRIPTION T Y Initial Release 10/19/05 TH R SM onnector Label I: LNHR/GPS-3-10 R SM onnector ttaches To: GPS Power ivider ttaches To: GPS ntenna 12.5" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 2 SM R ONNTORS P WIR & L 1 50 ohm OX S44191 P WIR & L opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde GPS R able, Sonde Storage ox NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV HIPR L iagram Rev 677VPS-3-10 SL 1 : 1 SHT 1 O 1

25 RV. SRIPTION T Y Initial Release 10/19/05 TH R TN onnector Label I: HSSIS/GPS-3-09 R TN onnector 25.75" ttaches To: Sonde Storage ox ttaches To: Telemetry hassis Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 2 TN R ONNTOR P WIR & L 1 50 ohm OX S44191 P WIR & L opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde GPS R L, Sonde Storage ox to Telemetry hassis NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-09 SL 1 : 1 SHT 1 O 1

26 RV. SRIPTION T Y Initial Release 10/19/05 TH 120V POWR PLUG Label I: P/120V-3-08 HOT GROUN RTURN R LK WHIT Plug PLUG SI VIW NOT: SHIL NOT US ttach To: omputer ttach To: Power Terminal Strip 39" R Qty SRIPTION PRT NO. MNUTUR Note: pply label I within 6" of each end and at 5' increments 1 onnector, Power / Plug, Hospital grade, 15/125V HL8215 Hubbell 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, POWR PLUG / 3-circuit SHURTR opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, OMPUTR NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-08 SL 1 : 1 SHT 1 O 1

27 RV. SRIPTION T Y Initial Release 10/25/05 TH MS ircular onnector ttaches to 28V Power Supply G H I J K L M N O 5" 8" 10.5" 28 V RM SOLNOI 28V 28V LUNH SOLNOI GROUN VLV OPN SIGNL Label I: LNHR/28V " 8" 10.5" G.... R S MS ircular onnector ttaches To: ropwindsonde Launcher ssembly inal length to be determined upon installation (Shall not exceed 30 ) R Qty SRIPTION PRT NO. MNUTUR Note: pply label I within 6" of each end and at 5' increments 1 onnector, MS ircular / MIL circuit MS S ITT annon 1 1 conductor 22 gauge wire, TLON WHIT M22759/1619W THRMX 1 1 conductor 16 gauge wire, TLON WHIT M22759/161619W THRMX 1 onnector, MS ircular / MIL circuit MS S ITT annon 6 rimp wire connector, covered with heat shrink tubing S18 3M opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Launcher ontrol able, to ropwindsonde Launcher ssembly NG: T. Hock 10/25/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-07 SL 1 : 1 SHT 1 O 1

28 RV. SRIPTION T Y Initial Release 10/19/05 TH R TYP "N" onnector Label I: HSSIS/400MHZ-3-06 R TYP "N" onnector ttaches To: 400 MHz UH lade ntenna ttaches To: Telemetry hassis Length to be determined upon installation (Shall not exceed 75 ) Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 2 TYP N R ONNTORS P WIR & L 1 50 ohm OX, RG-8 TYP S22089 P WIR & L opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde R OX L, UH NTNN NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-06 SL 1 : 1 SHT 1 O 1

29 Label I: LNHR/28V-3-05 RV. SRIPTION T Y Initial Release 9/7/05 TH MS ircular onnector ttaches to 28V Power Supply G H I J K L M N O 28 V RM SOLNOI 28V 28V LUNH SOLNOI GROUN VLV OPN SIGNL G H I J K L M N O P Q R S MS ircular onnector ttaches to Launch ontrol Panel 55" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, MS ircular / MIL circuit MS S ITT annon 1 1 conductor 22 gauge wire, TLON WHIT M22759/1619W THRMX 1 1 conductor 16 gauge wire, TLON WHIT M22759/161619W THRMX 1 onnector, MS ircular / MIL circuit MS S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Launcher ontrol able, Launch ontrol Panel to 28V Power Supply NG: T. Hock 9/7/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-05 SL 1 : 1 SHT 1 O 1

30 RV. SRIPTION T Y Initial Release 9/7/05 TH Label I: PS/28V-3-04 MS ircular Male onnector 28 Vdc GROUN NOT: SHIL NOT US R LK MS ircular onnector ttach to 28V Power Supply, Input ttach to Launch ontrol Panel 59" R Qty SRIPTION PRT NO. MNUTUR Note: pply label I within 6" of each end and at 5' increments 1 onnector, MS ircular / MIL circuit Male S-6P ITT annon 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, MS ircular / MIL circuit S-6S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, 28 Vdc Power Supply to Launch ontrol Panel NG: T. Hock 9/7/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-04 SL 1 : 1 SHT 1 O 1

31 RV. SRIPTION T Y Initial Release 9/7/05 TH 120V POWR PLUG Label I: PS/120V-3-03 HOT GROUN RTURN R LK WHIT MS ircular onnector PLUG SI VIW NOT: SHIL NOT US ttach to 28V Power Supply, Input 13" ttach to Terminal Strip Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, Power / Plug, Hospital grade, 15/125V HL8215 Hubbell 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, MS ircular / MIL circuit S-7S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, 28 Vdc Power Supply NG: T. Hock 9/7/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-03 SL 1 : 1 SHT 1 O 1

32 RV. SRIPTION T Y Initial Release 9/7/05 TH Label I: HSSIS/120V-3-02 MS ircular Male onnector HOT GROUN RTURN R LK WHIT MS ircular onnector ttach to ooling an NOT: SHIL NOT US 13.5" ttach to Telemetry hassis Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, MS ircular / MIL circuit Male S-7P ITT annon 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, MS ircular / MIL circuit S-7S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, ooling an unit to Telemetry hassis NG: T. Hock 9/7/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-02 SL 1 : 1 SHT 1 O 1

33 RV. SRIPTION T Y Initial Release 10/19/05 TH 120V POWR PLUG Label I: NS/120V-3-01 HOT GROUN RTURN R LK WHIT MS ircular onnector PLUG SI VIW NOT: SHIL NOT US ttaches to ooling an Input ttaches to Terminal Strip 31" Note: pply label I within 6" of each end and at 5' increments R Qty SRIPTION PRT NO. MNUTUR 1 onnector, Power / Plug, Hospital grade, 15/125V HL8215 Hubbell 1 3 conductor 16 gauge wire Teflon insulation STT T-1929(3) STJ TYP THRMX 1 onnector, MS ircular / MIL circuit S-7S ITT annon opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab (OL) 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde Power able, ooling an NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV 677VPS-3-01 SL 1 : 1 SHT 1 O 1

34 RV. SRIPTION T Y Initial Release 9/2/05 TH H H G L Monitor Video Input Video Signal Power 120V 60 Hz 3-wire Input Power 120V 60 Hz 3-wire Power Strip H K Power 120V 60 Hz 3-wire R. G H I J K L M N O rawing Number 677VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS VPS-3-15 G L P omputer Keyboard M Input Video RJ-45 Network Keyboard RS-232 Signal N I OX GPS R Power ivider To ircraft ata System OX Sonde Storage ox J OX GPS ntenna IRRT GPS R SIGNL Telemtry hassis ooling an RVR/PTU uffer Input MWG Log Rcvr Sonde Interface MWG P1 ata MWG SK emod GPS nt 400 MHz nt OX Output Input Power 120V 60 Hz 3-wire opyright 2005 University orporations for tmospheric Research, ll rights reserved. OX 400 MHz UH L NTNN National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O O ROPWINSON LUNHR ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 9/2/05 HIPR ROPSON INSTRUMNTTION SSMLY WIRING IGRM SIZ ile SM Name: NO WG NO RV VPS-2-02 SL 1 : 1 SHT 1 O

35 RV. SRIPTION T Y Initial Release 9/2/05 TH H H G LUNH ONTROL PNL G VIOR 28V SUPPLY ROPSON ISPNSR MOUNT ON RONT O INSTRUMNT RK 28 Vdc POWR SUPPLY MOUNT ON RR O INSTRUMNT RK 120V INPUT 28V OUT ONTROL PNL ISPNSR Power 120V 60 Hz 3-wire G TO ROPWINSON LUNHR SSMLY Power Strip MOUNT ON RR O INSTRUMNT RK opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 9/2/05 HIPR ropsonde ssembly Wiring iagram SIZ ile SM Name: NO WG NO RV HIPR L iagram Rev VPS-2-02 SL 1 : 1 SHT 2 O

36 RV. SRIPTION T Y Initial Release 10/26/05 TH H GPS R Signal xisting R oax H Sonde Storage ox (GPS Power ivider) H R oax wg. 677VPS Label I: GPS/LNHR-3-15 H 400 MHz R Signal H wg. 677VPS R oax I J I G 120 V 120 V ooling an wg. 677VPS-3-01 Power Label I: NS/120V-3-01 wg. 677VPS Power Label I: MONITOR/120V-3-11 wg. 677VPS Power L Monitor R oax wg. 677VPS Label I: LNHR/GPS-3-10 K Label I: HSSIS/400MHZ-3-06 Label I: HSSIS/120V-3-02 Video Signal Label I: HSSIS/GPS-3-09 wg. 677VPS I R oax H M Telemetry hassis R. G H I J K L M N O P ONNTOR TYP, SRIPTION Power Plug, 3-circuit Power, MS ONNTOR 3-PIN ML Power, MS ONNTOR 3-PIN ML Power, MS ONNTOR 6-PIN ML Power & SIGNL, MS ONNTOR 6-PIN ML Power & SIGNL, MS ONNTOR 15-PIN ML Power & SIGNL, MS ONNTOR 19-PIN ML R SIGNL, TYP N ML R ONNTOR R SIGNL, TN ML R ONNTOR R SIGNL, SM ML R ONNTOR VIO SIGNL, 15-PIN ML ONNTOR RS-232 OMPUTR SIGNL, 80-PIN ONNTOR RS-232 SIGNL, 9-PIN ML ONNTORS OMPUTR SIGNL, 15-PIN ML ONNTOR NTWORK SIGNL, 6-PIN, RJ-45 ONNTOR PSSIV GPS NT., P/N: L1RRKP-S, GPS Networking Inc. G Location: aggage compartment area wg. 677VPS Label I: MONITOR/VIO-3-12 wg. 677VPS omputer RS-232 Signal Label I: P/SRILXX-3-14 J P Passive GPS ntenna P/N. L1RRKP-S 120 V omputer Network wg. 677VPS Power Label I: P/120V-3-08 xisting Network able O P omputer K L N N wg. 677VPS omputer Signal Label I: P/K&MOUS-3-13 Keyboard ropwindsonde Launcher ssembly Part No wg. 677VPS Vdc Label I:LNHR/28V-3-07 G 120 V wg. 677VPS Power Label I: PS/120V Vdc Power Supply wg. 677VPS Vdc Label I:LNHR/28V-3-05 wg. 677VPS Vdc Launch ontrol Panel Label I: PS/28V-3-04 opyright 2005 University orporations for tmospheric Research, ll rights reserved. ONINTIL, ny unauthorized use, coping or distribution is prohibited. NG: T. Hock 10/26/05 National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O HIPR ropsonde Instrumentation lock Wiring iagram SIZ ile SM Name: NO WG NO RV HIPR ropsonde VPS-2-01 lock Wiring 677VPS-2-01 SL 1 : 1 SHT 1 O

37 RV. SRIPTION T Y Initial Release 10/19/05 TH R TN onnector Label I: GPS/LNHR-3-15 R SM onnector ttaches To: GPS Power ivider ttaches To: GPS ntenna Length to be determined at install Shall not exceed 30' Note: pply label I within 6" of each end and at 5' increments R P WIR & L able ssembly Part No Qty SRIPTION PRT NO. MNUTUR 1 SM R ONNTORS P WIR & L 1 50 ohm OX S44191 P WIR & L 1 TN R ONNTOR P WIR & L opyright 2005 University orporations for tmospheric Research, ll rights reserved. National enter for tmospheric Research arth Observing Lab 3450 Mitchell Lane, oulder O ONINTIL, ny unauthorized use, coping or distribution is prohibited. HIPR ropsonde GPS R able, Launcher GPS Reradiating ntenna NG: T. Hock 10/19/05 SIZ ile SM Name: NO WG NO RV HIPR L iagram Rev 677VPS-3-15 SL 1 : 1 SHT 1 O 1

P2-HSI High-Speed Isolated Sinking/Sourcing Input. Connector Specifications

P2-HSI High-Speed Isolated Sinking/Sourcing Input. Connector Specifications WARNG: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

DF64 Digital Frame Manual

DF64 Digital Frame Manual S Word Int 44.1 48 96 PU Select P ctive ustom Locked S W Int 44.1 48 96 PU Select P ctive ustom Locked S Sync S Sync MI Inputs MI Inputs In In Out Out Word Sync Word Sync In 75 In 75 Out Out irewire irewire

More information

FD70CV-M-C-9. Installation and Operation Manual. 7 NVG Compatible LCD. Revision Date: 06/16/2017 Page 1 of 12. Rev: A

FD70CV-M-C-9. Installation and Operation Manual. 7 NVG Compatible LCD. Revision Date: 06/16/2017 Page 1 of 12. Rev: A Page 1 of 12 Installation and Operation Manual FD70CV-M-C-9 7 NVG Compatible LCD Page 2 of 12 Specifications Display FD70CV-M-C-9 Panel Technology Diagonal Screen Size Native Resolution Pixel Pitch TN,

More information

O N W E I G H T S A N D

O N W E I G H T S A N D O N Standard eatures L display, (W x H) 4.6 in x 3.4 in Selectable character sizes from 0.25 in to 1.2 in 60 configurable operator prompts isplay up to four scale channels per screen with required Legal

More information

PERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE THREE-POLE, AUXILIARY CONTACTS

PERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE THREE-POLE, AUXILIARY CONTACTS INH-POUND MIL-PRF-39019/6H 14 May 0 SUPERSEDING MIL-PRF-39019/6G 27 ugust 1997 PERFORMNE SPEIFITION SHEET IRUIT REKERS, MGNETI, LOW-POWER, SELED, TRIP-FREE THREE-POLE, UXILIRY ONTTS This specification

More information

P P S - M W S C A N 1 H

P P S - M W S C A N 1 H µ-controller-systems / HARD- & SOFTWARE-DESIGN POWER-SUPPLIES FROM MILLIWATTS TO KILOWATTS Device: PPS-MWS-3000-4500-CAN1H 06 / 2017 Page 1 / 6 S w i t c h i n g M o d e P o w e r S u p p l y f o r M a

More information

Model /29S RF Splitter

Model /29S RF Splitter Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary

More information

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable RSSL1:1-KuXER Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System Outdoor Unit (ODU) Waveguide Switch & Status LNB 1 Coax cable Interface Terminal LNB 2 Indoor Unit Outdoor Unit Indoor

More information

ZDC RF Coax Connector Series 50 & 75 Ohm

ZDC RF Coax Connector Series 50 & 75 Ohm CONTACTORS CONNECTORS WIRE & CABLE EMI/RFI FILTERS CIRCUIT BREAKERS HARNESSING & PROTECTION IDENTIFICATIO I/RFI FILTERS CIRCUIT BREAKERS HARNESSING & PROTECTION IDENTIFICATION & LABELING PCB & CABLE ASSEMBLIES

More information

FD171CV-C-4. Installation and Operation Manual. 17 HDSDI Special Mission Quad Monitor. Revision Date: 01/11/2017 Page 1 of 14.

FD171CV-C-4. Installation and Operation Manual. 17 HDSDI Special Mission Quad Monitor. Revision Date: 01/11/2017 Page 1 of 14. Page 1 of 14 Installation and Operation Manual FD171CV-C-4 17 HDSDI Special Mission Quad Monitor Page 2 of 14 Table of Contents General Information...3 Front View...3 Additional Information...3 Specifications...4

More information

supported Digital Multi Switcher MSD-6208

supported Digital Multi Switcher MSD-6208 RoHS 4K@30 supported igital Multi Switcher Ver.1.1.0 (180529) The IK is a high-performance digital multi switcher with a scan converter and up to 8 inputs and 8 outputs. For video input, 8 digital and

More information

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz Mobile Communications MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO

More information

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE

More information

supported Digital Multi Switcher MSD-6203

supported Digital Multi Switcher MSD-6203 RoHS 4K@30 supported igital Multi Switcher Ver.1.3.0 (180907) The IK is a high-performance digital multi switcher with a scan converter and up to 8 inputs and 3 outputs. For video input, 8 digital and

More information

Installation Guide. PowerLogic LVCT. 1 VAC and.333 VAC Current Transducers

Installation Guide. PowerLogic LVCT. 1 VAC and.333 VAC Current Transducers Installation Guide PowerLogic LVT 1 V and.333 V urrent Transducers ontents Installation Overview... 2 Specifications... 2 Introduction... 3 escription... 3 Ratings... 3 imensions... 4 NGR HZR O LTRI SHOK,

More information

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M Sensored Termination (15 kv) QX-T15I-vi1-E 3M Sensored Termination () QX-T15I-vi1-E Data Sheet May 2016 Kit Contents: Each kit contains sufficient quantities of the following materials to make three single-phase terminations. 31" (REF) One piece

More information

FD171CV-C-1. Installation and Operation Manual. 17 LCD Monitor. Revision Date: 01/11/2017 Page 1 of 16. Rev: C. Document Number: MAN FD171CV-C-1

FD171CV-C-1. Installation and Operation Manual. 17 LCD Monitor. Revision Date: 01/11/2017 Page 1 of 16. Rev: C. Document Number: MAN FD171CV-C-1 MAN FD171V--1 Page 1 of 16 Installation and Operation Manual FD171V--1 17 LD Monitor 2017 FDS Avionics orp. TEHNIAL SUPPORT MAN FD171V--1 Page 2 of 16 Table of ontents General Information...3 Front View...3

More information

Instruction Manual Model BlockUpconverter

Instruction Manual Model BlockUpconverter Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic

More information

Instruction Manual Model # Block Upconverter

Instruction Manual Model # Block Upconverter Instruction Manual Model 2115-278# Block Upconverter August 2018, Rev. A MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

FD70CV-M-C-8. Installation and Operation Manual. 7 Widescreen LCD /Standard Arm. Revision Date: 05/17/2017 Page 1 of 14. Rev: A

FD70CV-M-C-8. Installation and Operation Manual. 7 Widescreen LCD /Standard Arm. Revision Date: 05/17/2017 Page 1 of 14. Rev: A MN FD70CV-M-C-8 Page 1 of 14 Installation and Operation Manual FD70CV-M-C-8 7 Widescreen LCD /Standard rm MN FD70CV-M-C-8 Page 2 of 14 Specifications Display FD70CV-M-C-8 Panel Technology Diagonal Screen

More information

ACTIVE IF SPLITTER/COMBINER UHP-IFS

ACTIVE IF SPLITTER/COMBINER UHP-IFS ACTIVE IF SPLITTER/COMBINER UHP-IFS GENERAL DESCRIPTION AND INSTALLATION GUIDE DOCUMENT RELEASE 2 [UHP.IFS.2.EN] JUNE 2016 CONTENT Acronyms and Abbreviations... 4 Introduction... 5 Required level of qualification...

More information

opengear OPG-1L 50 MHz-2.3 GHz

opengear OPG-1L 50 MHz-2.3 GHz MODEL opengear OPG-1L 50 MHz-2.3 GHz RF FIBER OPTIC LINK EMCORE s opengear OPG-1L s are optimized to perform in the 50 MHz to 2.3 GHz frequency range providing transparent signal transport for satellite

More information

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page

More information

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN BRK-1000 Series Ku-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

TECHNICAL SUPPORT , or   FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD TECHNICAL SUPPORT 678-867-6717, or www.flightdisplay.com FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD FD151CV-LP 15.1" Low Profile LCD 2006 Flight Display Systems. All Rights Reserved.

More information

E3/DS3 Fibre Extender

E3/DS3 Fibre Extender User Manual E3/DS3 Fibre Extender Black Box Network Services 464 Basingstoke Road, Reading, Berkshire, RG2 0BG Tech: 0118 965 6000 www.blackbox.co.uk CONTENTS 1 Introduction 1 1.1 About the products 1

More information

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1200-75 Amplifier August 2012, Rev. A LEVEL ADJUST POWER MODEL 1200 AMPLIFIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary to Cross

More information

Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide BBV Telemetry Receiver Installation Guide Models covered Rx200 Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323

More information

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1200-07 Amplifier September 2010 Rev A MONITOR J1 LEVEL ADJUST POWER MODEL 1200 AMPLIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary

More information

Active UTP Transceiver Hub Installation Guide

Active UTP Transceiver Hub Installation Guide Active UTP Transceiver Hub Installation Guide Models Include: HubWayEX16 - Sixteen (16) Channels - Thirty-two (32) Channels Rev. 011810 More than just power. TM Overview: Altronix HubWayEX16/EX32 Active

More information

User Manual. HDBaseT Receiver CMHDBTBRX. Front View Panduit Dr, Tinley Park, IL (708)

User Manual. HDBaseT Receiver CMHDBTBRX. Front View Panduit Dr, Tinley Park, IL (708) User Manual HDBaseT Receiver CMHDBTBRX Front View 18900 Panduit Dr, Tinley Park, IL 60487 (708) 532-1800 Back View TABLE OF CONTENTS Introduction 2 Features 3 Package Contents 3 Technical Specifications

More information

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or   Document Number: Rev: Page 1 of 16 FD104CV Installation and Operation Manual 10.4 LCD TCHNICAL SUPPORT 678-867-6717, or www.flightdisplay.com Page 2 of 16 FD104CV 10.4 LCD 2006 Flight Display Systems. All Rights Reserved. Flight

More information

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39 7.40 5.2 The Telemetrics Coax/Fiber Link is an affordable camera control system with increased operating distance. Using frequency multiplexing the following signals are transmitted over a single coaxial cable:

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

CLT-353R & CLT-353L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.1, 4/19/2013 preliminary

CLT-353R & CLT-353L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.1, 4/19/2013 preliminary CLT-353R & CLT-353L CAMERA LINK TRANSLATOR User s Manual Document # 201201, Rev 0.1, 4/19/2013 preliminary Vivid Engineering 159 Memorial Drive, Suite F Shrewsbury, MA 01545 Phone 508.842.0165 Fax 508.842.8930

More information

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz SIR-4002 MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz WIDE FREQUENCY RANGE: 0.5 26.5 GHz FEATURES Advanced Front Panel Alphanumeric Display High Dynamic Range: In band Input IP3 > 0 dbm, NF< 15 db DSP

More information

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO 18 GHz WIDE FREQUENCY RANGE: 0.5-18 GHz FEATURES High Dynamic Range Fast Switching Synthesizer with 10 Hz Tuning Resolution Excellent Phase Noise

More information

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2016-1250 Downconverter May 2009 Rev A F=2501.750 G=+25.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained

More information

Technical Description

Technical Description irig Multi Band Digital Receiver System Technical Description Page 1 FEATURES irig Multi Band Digital Receiver System The irig range of telemetry products are the result of a multi year research and development

More information

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO 26.5 GHz WIDE FREQUENCY RANGE: 0.5-26.5 GHz FEATURES High Dynamic Range Fast Switching Synthesizer with 10 Hz Tuning Resolution Excellent Phase

More information

CAT EXT-CAT USER MANUAL

CAT EXT-CAT USER MANUAL CAT5 8000 EXT-CAT5-8000 USER MANUAL www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday

More information

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS 11 GHz MDD FIBER OPTIC LINK FEATURES Small size Bandwidth to 11 GHz Plug-in optical connector No external control circuits required Transimpedance amplifier in both transmitter and receiver Custom transmitter

More information

E3/DS3 Tap. 6xBNC Type

E3/DS3 Tap. 6xBNC Type E3/DS3 Tap 6xBNC Type CUSTOMER SUPPORT INFORMATION To order or for a technical information support: Phone: +33 3 88 10 18 30 or Fax: +33 3 88 10 18 35 Mail order: COMCRAFT 2, rue de la Mairie 67203 Oberschaeffolsheim

More information

% & ) ANSI Accredited Program

% & ) ANSI Accredited Program PROUT RTIITION Pilot Operated Water onditioning & Purification Valves omposite ody to 2-WY pplications Water purification, conditioning and distribution in commercial/ industrial markets with reverse osmosis

More information

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac SM Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Features of the MultiMac SM Electronics Simultaneous Coil and/or Rotary Probe operation Differential

More information

CONNECTORS. Simple steps to guide you in using this catalogue. Applications. Options. Ordering Codes BNC 75Ω RF CONNECTORS

CONNECTORS. Simple steps to guide you in using this catalogue. Applications. Options. Ordering Codes BNC 75Ω RF CONNECTORS NC 75Ω RF CONNCTORS NC 75Ω RF CONNCTORS Within the internationally standardised NC mating face dimensions, a perfect 75 ohm characteristic impedance cannot be realised. However, at frequencies up to 1000

More information

Church Layout Medium Advanced

Church Layout Medium Advanced Specifier Product Information Church Layout Medium Advanced System Summary This summary is intended to explain, in general terms, some of the possible uses and reasons for having the recommended equipment

More information

FDSDIVCS-4-5 FDSDIVCS-4-10

FDSDIVCS-4-5 FDSDIVCS-4-10 Revision ate: Page 1 of 18 Installation and Operation Manual FSIVCS-4-5 FSIVCS-4-10 SI Video Crosspoint Switch Revision ate: Page 2 of 18 FSIVCS-4-5 FSIVCS-4-10 SI Video Crosspoint Switch 2014 Flight isplay

More information

Modular Block Converter Systems

Modular Block Converter Systems Modular Block Converter Systems The Modular Block Converter System eliminates system downtime and maximizes ease of repair by providing fully modular systems for up conversion or down conversion. Critical

More information

Specifications MAV Series Matrix Switchers

Specifications MAV Series Matrix Switchers Specifications MAV Series Matrix Switchers Video composite video and S-video models Routing MAV 44 Series... 4 x 4 matrix MAV 48 Series... 4 x 8 matrix MAV 62 Series... 6 x 2 matrix MAV 84 Series... 8

More information

Specifications MAV Series Matrix Switchers

Specifications MAV Series Matrix Switchers Specifications MAV Series Matrix Switchers Video Routing MAV 62... 6 x 2 matrix MAV 84 RCA... 8 x 4 matrix MAV 128 RCA... 12 x 8 matrix MAV 168 Series... 16 x 8 matrix MAV 1616 Series... 16 x 16 matrix

More information

ELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE

ELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE ELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE E0.01 FIRST FLOOR DEMOLITION E1.01 10 E2 11 12 12 G2 14 15 D1 D2 17 18 18 19 1 2 3 4 19 21 1 3 2 4 5 1 3 2 4 5 7 6 7 A2 E1 C2 A2 H1 H2 A1 E1 E2 6 8 A1 11 C1

More information

R e c e i v e r. Receiver

R e c e i v e r. Receiver R e c e i v e r Receiver > Eight channels > Eight configurable inputs > Three independent zones > Integrated 7-channel amplifier with massive toroidal transformer and thermal/dc protection > AM/FM tuner

More information

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment

More information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat8D - Eight (8) Channels HubSat82D - HubSat8D w/eight (8) HubWayAv Balun/s for s HubSat83D - HubSat8D w/eight (8) HubWayDv

More information

Key Features and functions. General Description

Key Features and functions. General Description Technical Specification Summary Frequency Range 470 862MHz Typ. Gain 56 db P1dB 1400 W Typ. Efficiency >40 % @ 1dBcp Analogue TV 2400 Wps Temperature Range 0 to +45C DVB 290 Wrms Max VSWR 3:1 DTV 500 Wrms

More information

Kinetix Application Note

Kinetix Application Note Applying 2094 LIM Modules to Multiple Loads Kinetix Application Note PURPOSE This document addresses application cases where it is desired to utilize a single 2094 LIM module to supply three phase power

More information

Digital Matrix Switcher (Scan converter output board) FDX-64

Digital Matrix Switcher (Scan converter output board) FDX-64 RoHS igital Matrix Switcher ( output board) FX-64 The IK FX series represent a new level of matrix switching for V systems. The FX series combine the simplicity and reliability of a fixed I/O matrix switcher

More information

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2584-31 Combiner May 2011, Rev. A RF MONITOR GAIN = -15 MENU MODEL 2584 COMBINER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained

More information

General Description. SC Configurations

General Description. SC Configurations S onnectors General Description Delta S series connectors are medium-size, 50Ω impedance connectors with 11 16-24 threaded coupling and good power handling capability, particularly those connectors noted

More information

Automatic Test System AT-S + with STAR + Technology Features

Automatic Test System AT-S + with STAR + Technology Features AT-S + with STAR + Technology Features AT-S + offers all the known benefits of our STAR technology, now also for AC safety power sources. It is the perfect symbiosis of CEWA GUARD and STAR technology.

More information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Installation. SAPTF33xx-1xx in the Network. Standard Configuration SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device

More information

I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:

More information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat4D - Four (4) Channel Passive UTP Transceiver Hub with Integral HubSat42D - Four (4) Channel Passive UTP Transceiver includes

More information

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

2014 Product Catalog

2014 Product Catalog 2014 Product Catalog What are the CleanStage products? CleanStage products are a toolkit for cabling your event s stage with signal and power, providing maximum time savings, operational efficiency, and

More information

Frameworx LCD Interface

Frameworx LCD Interface Pre-Installation & Installation Manual Frameworx LCD Interface February 2012 / 57-900073-000 Frameworx LCD Interface Pre-Installation & Installation Manual February 2012 by the Brunswick Bowling and Billiards

More information

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX 4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX 1 Contents CHAPTER 1. INTRODUCTION... 2 1.1 OVERVIEW...2 1.2 FEATURE...2 1.3 APPLICATION...3

More information

FDCONV-HDSDI-D VER SW FDCONV-HDSDI-S VER SW

FDCONV-HDSDI-D VER SW FDCONV-HDSDI-S VER SW Page 1 of 13 Installation and Operation Manual DCONV-HDSDI-D DCONV-HDSDI-S HDSDI Converter 2017 DS Avionics Corp. 470-239-7421 or DSAvionics.com Page 2 of 13 Table of Contents General Information...3 unctionality...3

More information

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422 remote control

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

12X SERIES. 12x1 Switcher. Video / Stereo-Audio or Video Only

12X SERIES. 12x1 Switcher. Video / Stereo-Audio or Video Only 12X SERIES 12x1 Switcher Video / StereoAudio or Video Only Instruction Manual Sigma Electronics, Inc. P.O. Box 448 1027 ommercial Ave. East Petersburg, PA 17520 (717) 5692681 Rev 1.2 (1001) REEIVG: It

More information

OPTOCORE Technology Overview. Topology and Connection Set-up. Yamaha Emulation Mode (YEM) Ring Topology

OPTOCORE Technology Overview. Topology and Connection Set-up. Yamaha Emulation Mode (YEM) Ring Topology Technology Overview is a synchronous, redundant, optical ring network capable to transport audio, video, control data and word clock over extremely long distances. The large variety of modules can all

More information

Specifications XTP CrossPoint 1600 and XTP CrossPoint 3200 Series

Specifications XTP CrossPoint 1600 and XTP CrossPoint 3200 Series Specifications XTP CrossPoint 1600 and XTP CrossPoint 3200 Series Video input XTP CP 4i, XTP CP 4i DMA Number/signal type... 4 sets of proprietary twisted pair AV signals Connectors... 4 female RJ-45 per

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

FIBERX DISTRIBUTION NETWORK SOLUTIONS

FIBERX DISTRIBUTION NETWORK SOLUTIONS IRX ISTRIUTION NTWORK SOLUTIONS INTROUTION hannell s bundled technology solutions will ensure accelerated return on investment when building and deploying passive fiber to the home (TT) networks. hannell

More information

C-Band Redundant LNB Systems

C-Band Redundant LNB Systems C-Band Redundant LNB Systems BRC-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

Digital Matrix Switcher (Scan converter output board) FDX-64

Digital Matrix Switcher (Scan converter output board) FDX-64 RoHS igital Matrix Switcher ( output board) FX-64 The IK FX series represent a new level of matrix switching for V systems. The FX series combine the simplicity and reliability of a fixed I/O matrix switcher

More information

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form

More information

Digital Matrix Switcher (Scan converter output board) FDX-32

Digital Matrix Switcher (Scan converter output board) FDX-32 RoHS igital Matrix Switcher ( output board) FX-32 The IK FX series represent a new level of matrix switching for V systems. The FX series combine the simplicity and reliability of a fixed I/O matrix switcher

More information

X-Band Redundant LNB Systems

X-Band Redundant LNB Systems X-Band Redundant LNB Systems BRX-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

GFT Channel Slave Generator

GFT Channel Slave Generator GFT1018 8 Channel Slave Generator Features 8 independent delay channels 1 ps time resolution < 100 ps rms jitter for optical triggered delays 1 second range Electrical or optical output Three trigger modes

More information

Digital Matrix Switcher (Scan converter output board) FDX-16

Digital Matrix Switcher (Scan converter output board) FDX-16 RoHS igital Matrix Switcher ( output board) FX-16 The IK FX series represent a new level of matrix switching for V systems. The FX series combine the simplicity and reliability of a fixed I/O matrix switcher

More information

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Inspection Features Versatile Threshold Selection Challenging test conditions are made simple

More information

FD104CV. Installation and Operation Manual 10.4 LCD. Revision Date: 08/01/2017 Page 1 of 14. Rev: G. Document Number: MAN FD104CV

FD104CV. Installation and Operation Manual 10.4 LCD. Revision Date: 08/01/2017 Page 1 of 14. Rev: G. Document Number: MAN FD104CV Page 1 of 14 Installation and Operation Manual FD104CV 10.4 LCD Page 2 of 14 Table of Contents eneral Information... 3 Front View... 3 Additional Information... 3 Specifications... 4 Installation Instructions...

More information

Installation Guide. Document Revision: 1.4 Part Number: Release Date: August, 2003

Installation Guide. Document Revision: 1.4 Part Number: Release Date: August, 2003 Installation Guide ocument Revision: 1.4 Part Number: 840-08472-03 Release ate: ugust, 2003 uphonix, Inc. 220 Portage ve. Palo lto, alifornia 94306 Phone: 650-855-0400 ax: 650-855-0410 Web: http://www.euphonix.com

More information

Single sensor setup with NIVEL210

Single sensor setup with NIVEL210 Single sensor setup with NIVEL210 Essential Items: 576 198 NIVEL210 RS232 748 335 Cable, Lemo 0 power supply cable Lemo 1 802 902 Cable, Lemo 0 722 409 Power supply plus power cords 802 902 576 198 748

More information

MAP110 AC-DC Series Data Sheet

MAP110 AC-DC Series Data Sheet Description Single-Output Model Selection VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012

More information

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this manual. Keep this

More information

FD104CV-C-L/R-1. Installation and Operation Manual LCD Monitor Left/Right Arm Mount. Revision Date: 07/28/2017 Page 1 of 13.

FD104CV-C-L/R-1. Installation and Operation Manual LCD Monitor Left/Right Arm Mount. Revision Date: 07/28/2017 Page 1 of 13. Page 1 of 13 Installation and Operation Manual FD104CV-C-L/R-1 10.4 LCD Monitor Left/Right Arm Mount TCHNICAL SUPPORT Page 2 of 13 Table of Contents General Information... 3 Front View... 3 Additional

More information

User s Manual. Document # , Rev 1.2, 6/12/2006

User s Manual. Document # , Rev 1.2, 6/12/2006 CAMERA LINK TM VIDEO SPLITTER User s Manual Document # 200205, Rev 1.2, 6/12/2006 Vivid Engineering 418 Boston Turnpike #104 Shrewsbury, MA 01545 Phone 508.842.0165 Fax 508.842.8930 www.vividengineering.com

More information

NanoCom ADS-B. Datasheet An ADS-B receiver for space applications

NanoCom ADS-B. Datasheet An ADS-B receiver for space applications NanoCom ADS-B Datasheet An ADS-B receiver for space applications 1 Table of contents 1 TABLE OF CONTENTS... 2 2 CHANGELOG... 3 3 INTRODUCTION... 4 4 OVERVIEW... 4 4.1 HIGHLIGHTED FEATURES... 4 4.2 BLOCK

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

MultiView 450. Installation & Reference Guide. Preliminary. Magenta Research Ltd

MultiView 450. Installation & Reference Guide. Preliminary. Magenta Research Ltd Preliminary MultiView 450 Installation & Reference Guide Magenta Research Ltd 934B Federal Road, Brookfield, CT 06804 USA (203) 740-0592 FAX (203) 740-0596 www.magenta-research.com Magenta Research Ltd

More information

OCS (Oval Contact System)

OCS (Oval Contact System) S--9 OS (Oval ontact System) S IS igh ensity: wide variety of insert arrangements available atterns range from () to (), 00 Ohm differential pairs capable of delivering data transfer speeds of 0bps per

More information

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708)

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708) User Manual HDBaseT Wallplate Transmitter over Cat6/6A Front View 18900 Panduit Dr, Tinley Park, IL 60487 (708) 532-1800 Back View TABLE OF CONTENTS Introduction 2 Features 3 Package Contents 3 Technical

More information

Basic & Safe. Industrial plugs and sockets

Basic & Safe. Industrial plugs and sockets asic & Safe Industrial plugs and sockets Screwless terminal connectors Highly reliable and safe products Easy to install thanks to clear terminal marking Resistant against vibrations and heat fluctuations

More information