1 CHRONOSCOPE M1 Instruction Manual Document Nr D35e Rel. 3.0 Witschi Electronic Ltd CH 3294 Büren a/aare Switzerland Phone +41 (0) Fax +41 (0) Internet

2 TABLE OF CONTENTS 1 GETTING STARTED DESCRIPTION OPERATING ELEMENTS AND DISPLAY CONNECTIONS COMMISSIONING EXTENT OF DELIVERY SETTING UP THE DEVICE Connecting the AM1 Microphone Mains Connection Connecting the Printer Initial Operation GENERAL INSTRUCTIONS SWITCHING ON AND OFF DISPLAY WHEN NO MEASUREMENTS ARE RUNNING CHOOSING FUNCTIONS AND SETTING UP PARAMETERS Procedure Choosing the Measuring Program Choosing the Measuring Mode Choosing a Function Setting up Parameters Editing Characters + Functions SYSTEM PARAMETERS Application language: date: time: screen contrast: light off: no signal: graph speed: print: print screen: autoprint: init pos micr: watch pos: autostart: idn: text: default parameters: ref:...16 Page 2 Chronoscope M1 Witschi Electronic Ltd

3 6.5 PRINTING RESULTS AND PARAMETERS Printing Parameters Numerical Results Diagram Printout and Scope Functions Printing Statistics Printing Saved Pages TESTING MECHANICAL WATCHES OPERATING PRINCIPLE Beat Noise Drawing Diagrams Rate Deviation Beat Error Amplitude SETTING THE GAIN ACOUSTIC CHECK PARAMETERS AND TOLERANCES program: name: beat mode: test mode lift angle: rate min p: / rate min x: rate max p: / rate max x: amplit min p: / amplit min x: amplit max p: / amplit min x: beat error: measuring time: resolution *** sequence *** positions: PROCEDURE CONTINUOUS MODE (CONT.) SEQUENTIAL MODE (SEQ.) TRACE MODE SCOPE MODE Scope 20 ms Scope 200 ms Scope 400 ms Witschi Electronic Ltd Chronoscope M1 Page 3

4 8 TESTING QUARTZ WATCHES OPERATING PRINCIPLE PARAMETERS AND TOLERANCES program: name: signal: rate min: rate max: measuring time: unit: MEASUREMENT: Digital Watches Watches with Stepping Motors CONNECTING A PC APPLICATION INSTALLATION DISPOSAL OF THE INSTRUMENT MAINTENANCE TECHNICAL DATA ACCESSORIES Page 4 Chronoscope M1 Witschi Electronic Ltd

5 1 GETTING STARTED Please read carefully all the information contained in this manual and strictly follow the operating instructions, which will help you to use and safely operate our product. Keep this manual in a safe place near the instrument and give it to any other user. The facility must be used only for the aims and purposes described in this very manual and must be set up and operated as described and under the conditions herein specified. The Manufacturer, Witschi Electronic AG in CH Büren a.a., Switzerland takes no responsibility and offers no warranty for damages that may follow from the non-observance of these directives or from inappropriate handling, such as damages to the checking device, to watches and/or people. Witschi Electronic Ltd Chronoscope M1 Page 5

6 Congratulations! You made the best choice. You bought CHRONOSCOPE M1, an extremely accurate checking device, technically reliable as well as easy to handle and operate. Follow the given instructions regarding usage and maintenance and you will enjoy CHRONOSCOPE M1 for quite a long time. It will be a pleasure and will prove profitable for you to use this device. 2 DESCRIPTION CHRONOSCOPE M1 is technically highly accurate and offers a wide range of new functions and possibilities as to the checking of mechanical watches. Thanks to its motor microphone (11 positions), the device proves to be perfect for timing adjustment, final control and any activity pertaining to a watch benchmark. The instrument allows the following basic functions: Noiseless graph tracing on a large LCD graphic display. Numerical display of the rate deviation, beat error and amplitude. Trace mode for the graphical drawing of the rate deviation and of the amplitude as a function of time. Scope function for the analysis of beat noise. Loudspeaker for the acoustic analysis of beat noise. Automatic test sequences with statistical evaluation. Most precise real time clock with date for accurate setting of the hands. CHRONOSCOPE M1 includes the following components: Measuring and display unit equipped with a large LCD graphic display. Operating unit with built-in motor microphone for mechanical watches and built-in sensor for quartz watches. Plug-in power supply for mains connection. Dust-proof cover. Optional parts: Clamp microphone for large watches and clocks. Optoelectronic sensor for pendulum clocks. Thermal printer Martel, for 100 V~ V~. GPS receiver to synchronize the real time clock (date is not synchronized) and to calibrate the time base. CHRONOSCOPE M1 operating is automated and is self-explanatory to a large extent as long as users deal with its basic functions. Should you wish to make the best use of its manifold possibilities, you will have to study the following instruction manual very carefully. Page 6 Chronoscope M1 Witschi Electronic Ltd

7 3 OPERATING ELEMENTS AND DISPLAY Operating elements are all set on the microphone and thus allow an easy and friendly use of the device. cont. / seq. print start / stop AM1 Knob cont./seq. print start/stop The knob allows choosing the kind of function and setting up parameters. It has a twofold function: users choose function or parameters by turning the knob and confirm their choice by pressing it. Switch-to button: continuous graph charting automatic test sequence. Button for printing the measuring protocol or the diagram. Button for starting and stopping measurements. Buttons for operating the microphone manually: The microphone rotates 45 0 to the left every time this button is pressed. The microphone rotates 45 0 to the right every time this button is pressed. The microphone dips 45 0 downwards every time this button is pressed. The microphone rises 45 0 upwards every time this button is pressed. Please note: Downward and upward motion is only enabled if the microphone is set in the horizontal position or if the crown is down. Rotation is disabled if the microphone is set in the 45 0 position downwards. Witschi Electronic Ltd Chronoscope M1 Page 7

8 LCD Screen signal The large 1/2 VGA screen displays complete information, i.e. real time clock with date, parameters settings, system settings, diagrams, results, statistics, drawing of the beat noises, calibration, etc. The display is divided into three fields when the measuring function is operating: The upper field displays the current numerical results as well as information about the measurement in progress. The middle field displays graphic results such as diagrams or oscillograms. The numerical results of the whole cycle are displayed at the end of each measuring cycle. The lower field shows the menus and parameters accessible through the rotary knob. LED display showing the signal level. Page 8 Chronoscope M1 Witschi Electronic Ltd

9 4 CONNECTIONS Rear panel sensor PC printer calibration power 12 V /1 A Connection of the AM1 motor microphone. RS232 connection to a PC. RS232 connection to the Martel MCP7810 thermal printer. Connection to the Witschi GPS receiver. Connection to the mains adapter. DIN connector Rear side of the microphone - Clamp microphone for testing large watches and clocks. - Optoelectronic sensor for testing pendulum clocks. Witschi Electronic Ltd Chronoscope M1 Page 9

10 5 COMMISSIONING 5.1 EXTENT OF DELIVERY The basic equipment comprises the following components: CHRONOSCOPE M1 testing device AM1 microphone Mains adapter. Dust-proof cover. Instruction Manual. 5.2 SETTING UP THE DEVICE Warning: When installing the device, avoid direct proximity to very high temperatures and direct exposure to the sun which negatively influences the readability of the display. Loud noises impair the signal reception of the microphone, which must obviously be kept at a reasonable distance from noisy machines, loudspeakers and particularly from ultrasonic cleaning equipment Connecting the AM1 Microphone Connect the motor microphone to the sensor connector. You can also connect the several signal sensors available as accessories to the DIN connector on the rear side of the microphone. Note: The AM1 microphone is an integral component of the device. All operating elements are placed on AM Mains Connection Power is supplied to the CHRONOSCOPE M1 through a plug-in power supply with an output voltage of 12 V DC and a power of 12 W. Mains adapters are available for a mains voltage of 230 V~ (range 210 V~ V~) or for a mains voltage of 120 V~ (range 110 V~ V~). BEFORE CONNECTING FOR THE FIRST TIME, MAKE SURE THAT THE VOLTAGE OF THE POWER SUPPLY CORRESPONDS TO THE VOLTAGE OF YOUR MAINS. Only use a mains adapter of the original type: 12W/12V-N1EFS (230 V~) or 12W/12V-N2UFS (120 V~). Connect the mains adapter to the suitable socket on the rear panel. We recommend disconnecting the power supply from the mains during longer idle periods, e.g. vacations. Page 10 Chronoscope M1 Witschi Electronic Ltd

11 5.2.3 Connecting the Printer Connect the thermal printer Martel MCP7810, available as an accessory, to the connector printer. The connecting cable is delivered together with the printer: the device is configured exclusively for this type of printer (also for the previous model). CAUTION! Before connecting the printer make sure that the voltage of its power supply corresponds to the voltage of your mains Initial Operation Connecting the power initializes the device which is automatically switched on. The display only shows the following information the first time the device is switched on after having been connected to the mains. The device is fitted with a quartz oscillator stabilized in temperature and thus needs 20 seconds to reach perfect accuracy after connecting to the supply (quartz warming up). All the program parameters settings remain saved even when the device is disconnected from the mains. Your device is now operative. Operating and possible settings are described in the following chapters. If your device is equipped with the printer, remember to switch on the printer as well. Note: Do not forget to switch off the printer after use. Unplugging the power supply is not enough and the accumulator will discharge. Witschi Electronic Ltd Chronoscope M1 Page 11

12 6 GENERAL INSTRUCTIONS 6.1 SWITCHING ON AND OFF As long as the device is supplied with power no further stabilizing time needs to elapse after switching it on. To switch on the device: shortly press the rotary switch. To switch off device: rotary switch to the symbol Ф (switched off) and then shortly press the switch. Once switched off, the device remains in stand-by mode, during which the thermal stabilization of the time basis is on. We recommend disconnecting the device during longer idle periods of time. Shouldn t you need to use the device for an extended period of time (e.g. vacations), it will prove necessary to disconnect the power supply from the mains. Power consumption: 12 W in normal mode and 5 W in standby mode. 6.2 DISPLAY WHEN NO MEASUREMENTS ARE RUNNING As long as no signal from the watch is received, time and date are displayed after the device has been switched on. The display also shows the following image when no usable signal from the watch is available or when it exceeds the measuring range. Amplitude or out range will be displayed instead of no signal on the upper left side of the screen. When the GPS receiver is connected and the connection to the satellite does not present any problems, received data are confirmed as follows: RTC = (Real Time Clock) universal time PPS = (Pulse Per Second) reference signal 1 Hz Page 12 Chronoscope M1 Witschi Electronic Ltd

13 6.3 CHOOSING FUNCTIONS AND SETTING UP PARAMETERS Procedure The knob allows you to choose a menu, the measuring program, the measuring mode or a function. Proceed as follows: Choosing the Measuring Program Point the cursor to the name of the chosen program, and then shortly press the knob. The name of the program is bracketed to the left and to the right by the characters > and <. Now you can select the program you need by turning the knob to the left or to the right, and then confirm the program selection by shortly pressing the knob Choosing the Measuring Mode Same procedure as described above. You can choose between the cont./seq. (it can be set by means of the cont./seq. button), the Quartz, the Trace and the Scope measuring modes. Note: Measuring mode cannot be selected when: - a measurement has been stopped - the seq. Measuring mode is on Choosing a Function Same procedure as described above. The following functions can be selected and set up: - Loudspeaker on/off. - Gain of watch signal, from 1 to 4. - Diagram resolution (magnifier) from 1to Setting up Parameters Point the cursor to the Syst or Param menu. The windows have several entry fields. In order to edit the parameters, follow the procedure described below: Choose the parameter with the knob and click; you can now edit the selected parameter as requested by means of the knob (s. next chapter). Once you have finished click with the knob. The edited parameter is saved and the cursor then returns to the name of the parameter. You can interrupt the editing at any time by means of the start/stop button and if you press again the button, the cursor returns directly to the mode measure Editing Characters + Functions The cursor (bar) is set under the first character. You can select one of the characters (and also a function depending on the parameter) by means of the knob, even an empty space. When you shortly press the knob the cursor moves to the next character, which you can select the way you did with the previous one and so on. Witschi Electronic Ltd Chronoscope M1 Page 13

14 6.4 SYSTEM PARAMETERS Application Setting up the system parameters is performed as a rule only once, in most cases after the device has been installed and switched on for the first time language: You can choose among one of the following languages: German, French, English, Spanish and Italian date: You can set the date of the built-in clock (dd.mm.yyyy) Note: The date is not synchronized by the GPS receiver and must be, if necessary, manually set time: You can adjust the time of the built-in clock. Note: If a GPS receiver is connected, you can adjust only the Hour (in accordance with the time zone). The GPS receiver automatically synchronizes minutes and seconds (date is not synchronized) screen You can choose between two types of display: Normal Black characters/symbols on a white background Inverse white characters/symbols on a black background contrast: You can choose the most suitable contrast of the LCD screen light off: When you do not actuate any operating elements, the background light goes off automatically after the pre-set time (1-60 minutes) has elapsed. The light automatically switches on again as soon as you actuate an operating element. Page 14 Chronoscope M1 Witschi Electronic Ltd

15 6.4.8 no signal: You can choose between two kinds of setting. clock If the microphone does not receive any signal, time and date are then displayed. freeze If no new signal is received, the last valid picture remain on the display graph speed: You can set the speed of the diagram tracing: 1/1 (normal), 1/2, 1/4 and 1/8. Diagram velocity for a number of beats equal to 28,800 b/h: 1/1 = 80 s for monitor length 1/2 = 160 s for monitor length 1/4 = 320 s for monitor length 1/8 = 640 s for monitor length print: You can choose between two settings. Protocol You can print numerical measuring results by pressing the button print, otherwise tables containing all results will be automatically printed after a programmed measuring cycle has been completed. The printout will show the date, the time, the name of the program together with the parameters, measuring position and header. Diagram After pressing the button print the diagram keeps on being printed until the button is pressed again or until the watch is removed from the microphone print screen: You can choose between two settings. Normal You can print the needed information from the screen with a the width of 10 cm. Large In order to render the printed contents of the screen more legible you can print with a width of 25 cm. This setting increases the quantity of printed paper by a factor of autoprint: You can choose between two settings. Yes Automatic printout of the result table after a sequential measuring cycle is finished. No The printout occurs manually, if desired init pos micr: You can choose among three different microphone start positions: Horiz Horizontal positioning Verti Vertical positioning (9H or KU). HV45 0 The microphone has an inclination of 45 0 forward watch pos: You can choose the position of the watch on the microphone: ZO Dial upwards. ZU Dial downwards. Witschi Electronic Ltd Chronoscope M1 Page 15

16 autostart: You can choose if a measuring cycle should automatically be restarted after a fixed period of time between two starts. Selecting YES, you can enter a delay lasting from 1 to 99 minutes. You can carry out long-term measurements, i.e. over 24 hours by means of this function idn: Display of the equipment's identification number. The number can not be modified text: The device as delivered displays the following written texts: 1: Witschi Electronic AG 2: CH-3294 Bueren a.a. 3: Name, nom, nombre, nome You can freely edit the three 24-character lines according to your requirements and replace them with your own information. If your device is equipped with a printer, the whole text (called also header) will be printed together with the results default parameters: If you select YES, the system parameters set up by Witschi will be automatically selected ref: You can choose the signal source necessary to calibrate the device: GPS, MAG or CAP. (s. Calibration chapter) 6.5 PRINTING RESULTS AND PARAMETERS The following chapters only apply to devices equipped with a printer Printing Parameters Press the print button from the Parameter or System Menu and the data shown on the screen will be printed out together with header, date, time Numerical Results Press the button print while a diagram is being displayed for immediately printing out the displayed numerical results referring to rate, beat error and amplitude; header, date, time, program name, number of beats, lift angle and measuring time will also be printed out. The display in progress will not be interrupted at all. After each printing, enough paper is fed forward so that the strip can be torn off and placed with the watch Diagram Printout and Scope Functions In order to print out the data on the screen (print screen), proceed as follows: - Press the start/stop button to pause the display. - Now press the print button to print the contents of the display. - In order to resume the measuring process, press again the start/stop button. The header, date, time, program number and program name will be printed together with the results. Page 16 Chronoscope M1 Witschi Electronic Ltd

17 6.5.4 Printing Statistics Statistical results are automatically printed out at the end of each measuring cycle as a table with header, date and time Printing Saved Pages After several pages (max. 4) have been drawn in modes cont., seq. or Trace you can display and print them later. Switch the knob on the upper right side of the screen to PO and shortly press it. Then rotate the knob to recall the single page/s. Press the print button to print out the needed page/s. Witschi Electronic Ltd Chronoscope M1 Page 17

18 7 TESTING MECHANICAL WATCHES 7.1 OPERATING PRINCIPLE The following information will help you understand the operating principle of CHRONOSCOPE M1 and will lead you to a correct interpretation of the displayed pictures Beat Noise The beat noise of the watch is generally made of three different kinds of impulse: The first noise is generated by the ellipse, situated on the balance wheel, touching the pallet fork (A). This noise s timing is very accurate and is thus used for drawing diagram and for the calculation of the rate deviation as well as of the beat error. Another noise is generated by the pallet freeing itself from the escape wheel. Being very irregular, this noise is not used for analysis (B). The third and most powerful noise is generated by the escape wheel falling on the pallet of the pallet fork (C). This noise is used to for the calculation of the amplitude. A B C How beat noises are generated Page 18 Chronoscope M1 Witschi Electronic Ltd

19 Further noises, which can be of different strengths, are also generated by friction or by secondary causes. A C Graph - Beat noise For the sake of the analysis it is of extreme importance to exactly detect the beginning of the first noise packet A. Should this noise be very weak in a watch or should the watch generate strong secondary noises, then the gain must be adjusted accordingly. You should always keep in mind that the beat noise is not generated by single strong impulses but by mechanical noises which rise, reach their maximum and then decrease. Therefore measured times always depend to a certain extent on the gain setting and the momentary form of signal Drawing Diagrams To draw diagrams, the time elapsed between two consecutive beats (period) is measured and compared with the nominal value for a precise beat. If the measured time exactly corresponds to the nominal value, the new point will be set on the diagram exactly next to the previous one. If the new beat is too fast or slow the new point will be shifted upwards or downwards relatively to the last point according to its time difference from the nominal value. A line made up of points will thus be displayed, either as a straight line or a line curving upwards or downwards according to the rate deviation. It goes without saying that the diagram not only shows the rate deviation but also other time-related irregularities, such as beat errors, faulty escape wheel teeth and so on Rate Deviation In order to calculate the rate deviation, the differences between the measured period and the nominal value are averaged over the measuring time, converted to s/24h and then displayed on the screen. Witschi Electronic Ltd Chronoscope M1 Page 19

20 7.1.4 Beat Error The message 0.0 ms appears on the screen if the period between a tick and a tack is equal to the period between a tack and a tick. In case of a watch beat error (repère) the period between a tick and a tack is not equal to the period between a tack and a tick. The time difference is averaged over the set measuring time and displayed Amplitude In order to calculate the amplitude, the time between impulse A and impulse C in the beat noise is measured. The balance wheel revolves by a certain angle between these two impulses. This so-called lift angle is determined by the design of the clockwork and must be entered as a parameter. The larger the amplitude of the balance wheel, the higher the velocity at which it travels through the lift angle and hence, the shorter the time it needs to travel through the angle. The amplitude can therefore be calculated from the time elapsed between impulse A and impulse C as beat noise, taking into account the number of beats and the lift angle. The device always calculates the amplitude as an average over the set up measuring time. 7.2 SETTING THE GAIN The gain control of the watch signal takes place almost fully automatically. Should problems arise regarding the acquisition of the signal (too weak signal or secondary noise), you can change the level of the signal gain. With the knob click number on (1-4) near the symbol. Then turn the knob to select a different gain level; 1 is the lowest and 4 the highest signal gain. Confirm the new setting by clicking the knob. We recommend setting 2 for watches that do not present signal acquisition problems. 7.3 ACOUSTIC CHECK You can check the beat noise of the watch (irregularity and secondary noise) by means of the builtin loudspeaker. To switch the loudspeaker on and off, click on the symbol of the loudspeaker with the knob: = on X = off. We recommend carrying out an acoustic check every time the diagram looks suspicious or shows irregularities which cannot be readily explained. Page 20 Chronoscope M1 Witschi Electronic Ltd

21 7.4 PARAMETERS AND TOLERANCES You can edit and save 99 complete parameter sets for testing mechanical watches according to your requirements program: Choose one of the 99 program numbers available (01/99 to 99/99): in steps of 10 and after pressing the rotating knob in steps of name: There are 8 characters available to enter the name of the program beat mode: You can choose among three settings: aut In this position, the device analyses the number of beats of the watch to be measured. The following beat numbers are automatically selected: , , , , , , , 32'400 and b/h. man This position is necessary when testing watches with an obsolete number of beats. You can set any value between and b/h. frq This function determines the frequency. You can set up the number of beats of an unknown watch. The number of beats displayed corresponds to a rate = 0 s/24h test mode You can choose among 4 settings: stnd Amplitude and beat error measurement is on. You must enter the lift angle for the watch to be tested. (the angle is needed to calculate the amplitude). rate When the amplitude and beat error measurement is off, it is possible to draw diagrams and measure rates even with watches giving off a bad or unusual beat noise. (In this case amplitude and beat error are not displayed). Spe1 This mode must be set, if watches with coaxial escapement should be measured. Spe2 This mode must be set, if watches with AP escapement should be measured. Witschi Electronic Ltd Chronoscope M1 Page 21

22 lift angle: The lift angle can be set between 10 o and 90 o. Caution: A wrong setting of the lift angle yields an erroneous amplitude value. You can find the necessary information about most watch calibers produced in Switzerland in our brochure Scope / Number of beats rate min p: / rate min x: * You can enter the minimal rate tolerance, which can be set up between and +10 s/d rate max p: / rate max x: * You can enter the maximal rate tolerance, which can be set up between and +50 s/d amplit min p: / amplit min x: * You can enter the minimal amplitude tolerance, which can be set up between and amplit max p: / amplit min x: * You can enter the maximal amplitude tolerance, which can be set up between and p = tolerances of the test positions. x = tolerances of the average over all test positions beat error: You can enter the maximal beat error, between 0.0 and 5.0 ms. * Crossed tolerance values (min. > max.) are not accepted measuring time: You can choose between two settings. aut s The measuring time depends on the number of beats. The deviation rate is displayed after every four beat noises. xxx s The measuring time can be set up between 2 and 240 s by means of the default values: Aut s resolution You can choose the resolution for the numerical rate display, 1 s/d or 0.1 s/d *** sequence *** Applicable only in the seq. mode. If you need an automatic test sequence you can enter the stabilizing times after changing testing position, automatically (aut s) or manually between 1 and 99 s. In the (aut s) mode the stabilizing time is determined by the beat number: beat number (b/h) stabilizing time (s) 18' ' ' ' ' Page 22 Chronoscope M1 Witschi Electronic Ltd

23 Stabi VV/HH Stabi VH/HV Stabilizing time from a vertical position to another vertical position or from a horizontal position to another horizontal position. Stabilizing time from a vertical position to a horizontal position and vice versa positions: You can choose one of the 4 programmed default test sequences or manually enter a custom test sequence with a maximum of 11 test positions. aut3 Automatic test sequence with 3 test positions: DU - CD - CL aut4 aut5 Automatic test sequence with 4 test positions: DU - CD - CL - CU Automatic test sequence with 5 test positions: DU - DD - CD - CL - CU aut6 Automatic test sequence with 6 test positions: DU - DD - CD - CL - CU - CR Note concerning the new definition of vertical test positions: CD 9H CL 6H CU 3H CR 12H All positions in between are defined, for instance: 9H To manually enter a test sequence, proceed as follows: - Select the man parameter and briefly press the rotary knob (rotary knob click). The cursor will then spring on to the first measuring position of a test sequence. - Turn the knob left and/or right until you reach the needed measuring position for the first measurement. Confirm the position with a rotary knob click; the cursor will spring on to the next measuring position. You can now enter the measuring position for any further measurement of the test sequence. You can enter from 1 to max. 11 measuring positions. - When you have finished entering data, shortly press the rotary knob in order to save the test sequence. Note: If after entering e.g. the fifth measuring position you do not need any further one for the test sequence, keep on turning the rotary knob for the sixth measuring position until a bar instead of a measuring position appears. A bar will also appear for all other measuring positions. 7.5 PROCEDURE Use the rotary knob to select the needed measuring mode cont., seq., Trace or Scope and then the appropriate program for measuring the watch. Draw the watch to be tested on the microphone until the stem sits as close as possible to the fork of the signal transducer. As soon as a usable watch signal is detected, the light diode signal starts flashing following the rhythm of the watch rate and the graph charting starts automatically. Witschi Electronic Ltd Chronoscope M1 Page 23

24 7.6 CONTINUOUS MODE (CONT.) The diagram is continuously drawn in this mode. You can turn the microphone to the needed control position by pressing the arrow keys. Due to the display principle of the LCD graphic screen, the following differences relatively to drawing a graph on paper strips have to be mentioned: - The points of the diagram are shown as screen dots (pixels) on the display. These dots are placed at a distance of 0.3 mm from each other. An inclined diagram is thus always shown as a staircase with 0.3-mm steps; the distance between the lines will of course be a multiple 0.3 mm. - This effect only shows in the case of accurate watches and low diagram resolution. It is generally overshadowed by the natural irregularities of the diagram. We therefore recommend always to use a resolution which perfectly fits the quality of the watch and which is the highest possible. You can set the resolution (magnifier) between 1 and 9 by clicking the rotary knob on the magnifier symbol and then rotating the knob. The numerical results concerning rate measurements, amplitude measurements and beat error measurements are shown at the end of the first cycle of the selected measuring time. If you set up a longer measuring time, the result will be calculated as the average of the single measurements. The average is continuously re-calculated every 2 s; this means that in case of a 20 s measuring time, the last 10 measurements each 2 s will always be considered as valid for computing the average value. The running bar under the diagram indicates the diagram section that has been used. Results are significant and stable when their diagram is also clean and smooth. The longer the selected measuring time is, the more stable the displayed result is, since short-lasting irregularities in rate are not taken into account. When the graph charting is displayed over several screen lengths (page), the data displayed in max. 4 screens will be saved. Page 24 Chronoscope M1 Witschi Electronic Ltd

25 Press the start/stop button to look at single pages; use the rotary knob to select PO in the upper right side of the screen, then briefly press the knob and call any single page by rotating the knob. You can also stop the drawing at any time by means of the start/stop button. A new start will clear the previous drawing and a new one will be started. Other displayed information is the current test position of the watch, the number of beats, the set up lift angle and measuring time. Witschi Electronic Ltd Chronoscope M1 Page 25

26 7.7 SEQUENTIAL MODE (SEQ.) This mode is specifically designed for automatic test sequences. Select the measuring mode cont. with the rotary knob, then press the button cont./seq. The measuring mode is now seq., the still empty table results and statistics now appears on the LCD screen. Now select the program under which the test sequence is to be carried out, place the watch on the microphone and press the start/stop button to start the test sequence. The microphone reaches the first test position and graph charting starts after the stabilizing time has elapsed. Once the measuring time has also elapsed the microphone reaches the next test position so that the diagram is drawn after the stabilizing time until all positions (max. 11) have been run through. The example given hereafter refers to 6 positions: aut6 At the end of the test sequence all results and statistics are shown in the form of a table. The table is automatically printed out if the printer is on. Results at measured positions are displayed on the left part of the screen, whereas the right part of the screen shows the statistical analysis with a resolution of 0.1 s/d. The following values are displayed next to the rate, amplitude and beat error measured at each test positions: D maximal difference between the several test positions X average over all test positions XH average over horizontal test positions DVH difference between vertical and horizontal average values Xv average over vertical test positions DV maximal difference between the vertical test positions The values Xv, XH, DVH, DV are only valid in measuring modes aut3, aut4, aut5 or aut6. (s. Chapter ) Page 26 Chronoscope M1 Witschi Electronic Ltd

27 Out of tolerance measuring results are marked with an arrow: = exceeding max. tolerance limit. = lower min. tolerance limit. The diagrams drawn during the test sequence are saved (max. 3 pages) and can be called. Select PO in the upper right part of the screen using the rotary knob, then briefly press the knob and call any single page by rotating the knob, as shown in our example: Print out single pages by pressing print button. Note: Depending on the number of test positions and on the selected measuring time, it may happen that the three pages available for the graph charting are not sufficient (P0 is available only for results and statistics). In this case the first test positions will always be omitted. Witschi Electronic Ltd Chronoscope M1 Page 27

28 7.8 TRACE MODE Trace mode allows the simultaneously draw the deviation of the rate and the amplitude as a function of time. The drawing starts after the first time the set measuring time has elapsed and is then updated every 2 seconds. The upper part of the LCD screen displays the amplitude, the lower part the rate deviation. The device also carries out quite a useful short-time analysis lasting 20 minutes and taking the whole width of the screen. Since at most 4 screen widths can be saved, the drawing takes in this case up to 80 minutes. You can double the resolution of the drawing with the magnifier function, by setting up its value to 2. You can also stop the drawing at any time with the start/stop button. A new start will clear the previous drawing and a new one will be started. The diagrams drawn during the measuring process are saved (max. 4 pages) and can be called. Use the rotary knob to select PO in the upper right side of the screen, then shortly press the knob, rotate it in order to call single pages, as shown in our example. The current test position of the watch, the beat number, the programmed lift angle and the measuring time are simultaneously displayed. Note: Press the print button to start printing the protocol. To print out the data shown on the screen (print screen) press the start/stop button and then the print button. If you select the aut measuring time, the 20 minutes needed to draw along the whole screen width no longer apply. The time needed to draw the graph will thus depend on the number of beats. Page 28 Chronoscope M1 Witschi Electronic Ltd

29 7.9 SCOPE MODE The Scope function allows the acoustic beat noise of the watch to be graphically displayed. The beat noise is shown in the form of an envelope of the max. and min. signal amplitudes. In order to make the best use of the limited dimensions of the display, only the positive half of the symmetrical watch signal is shown. Scope functions do not allow displaying numerical results. Such a display of the beat noises renders escapement errors and/or secondary noises immediately obvious. Our detailed brochure on calibration and scope functions allows you to detect immediately the cause of the error. You can stop the graphic displays by pressing the start/stop button in order to view them and print them out. Use the knob to select Scope mode, then select the parameter for the time range of the display. You can choose between the following values: 20 ms, 200 ms and 400 ms (ms = Milliseconds). You can set up the vertical signal gain by clicking the knob on the number (1-4) next to the symbol. Set up the gain by rotating the knob Scope 20 ms This kind of graph is displayed with a 20 ms time range. A whole beat noise is displayed on the screen. The trigger is set so that alternating ticks and tacks are drawn. If you have entered the right number of beats in the menu parameter, the oscillogram also displays the amplitude value. The trigger point for the amplitude measurement will be shown as a perpendicular line marking the highest amplitude value. Note: This operating mode does not allow the device to automatically determine the number of beats. Witschi Electronic Ltd Chronoscope M1 Page 29

30 You can check if the quality of the watch signal allows a precise evaluation of the amplitude. The amplitude value must be considered as an instantaneous value that may differ slightly from the actual value. During a standard measurement at least 16 impulses are analyzed and interpreted for a number of beats equal to b/h. Scope mode allows interpreting only one impulse at a time. In this case, the amplitude value is displayed with a 20 ms time range Scope 200 ms This kind of graph is displayed with a 200 ms time range. Depending on the number of beats, the screen displays 2 to 3 succeeding beat noises. The graphic display starts alternatively with a tick and a tack. This kind of graph is used for analyzing secondary noises occurring between beat noises Scope 400 ms This kind of oscillogram is displayed with a 400 ms time range. Depending on the number of beats, the screen displays 3 to 5 succeeding beat noises. The graphic display starts respectively with alternating ticks and tacks. Page 30 Chronoscope M1 Witschi Electronic Ltd

31 8 TESTING QUARTZ WATCHES 8.1 OPERATING PRINCIPLE The Motor test mode is characterized by the presence of a sensor for the magnetic field from the motor coil. This kind of test can be used for all watches equipped with a stepping motor. LCD test mode allows evaluating the operating frequency of the LCD display of a watch for the measurements. All the frequencies which are a multiple of 4 Hz can be processed. When the automatic measuring time Aut is selected, the graph for analogue quartz watches is displayed at the end of a motor pulse period, after 2 seconds at the earliest. In the case of LCD quartz watches the display occurs after 2 s. If the rate deviation during short-time measurements exceeds +/- 1 s/d, the device operates as if it were dealing with an inhibition watch and automatically switches to a 60 s measuring time, which implies that the first measuring result will be shown after 1 minute. 8.2 PARAMETERS AND TOLERANCES You can program and save 5 complete parameter sets of for quartz watches according to your requirements program: Choose one of the 5 available program numbers (1/5 to 5/5) name: 8 characters available to enter the program name signal: Choose between two settings to measure rate accuracy. Motor magnetic recording of the stepping motor pulses. LCD capacitive signal recording of the LCD operating frequency. GPS CAUTION! In conformity with the quality standard ISO 9000, this setting is to be used only to test the internal time-base; such tests can only be carried out with the appropriate GPS receiver. Witschi Electronic Ltd Chronoscope M1 Page 31

32 8.2.4 rate min: You can enter the min. rate tolerance, from to s/d in 0.10 s/d to 0.01 s/d steps. Crossed tolerance values are not accepted (min. > max.) rate max: You can enter the max. rate tolerance, from to s/d in 0.10 s/d to 0.01 s/d. steps. Crossed tolerance values are not accepted (min. > max.) measuring time: You can choose between two settings: aut s The measuring time depends on the period of the stepping motor pulses xxx s Measuring time settings: from 10 to 480 s : Aut s unit: You can choose the unit for in which the accuracy will be displayed: 0.01 s/d (seconds / 24 h) or 1 s/m (seconds/month). 8.3 MEASUREMENT: Use the rotary knob to select the Quartz measuring mode and then the appropriate program to measure the watch. Place the watch to be tested on the sensor surface located on top of the microphone casing; analogue quartz watches with case s back cover and digital quartz watches with LCD display downwards Digital Watches The LED is always on when testing digital quartz watches. Should the signal be weak, it is advisable to slightly shift the watch on the transducer. The diagram is continuously drawn. Page 32 Chronoscope M1 Witschi Electronic Ltd

33 8.3.2 Watches with Stepping Motors With an analogue quartz watch, the light-emitting diode signal flashes according to the rhythm of the stepping motor pulses and displays the signal intensity. Should the signal be weak, it is advisable to slightly shift the watch on the transducer. The diagram charting starts automatically as soon as a signal is received. Each motor pulse is displayed. The example shows the diagram recorded for an analogue quartz watch with a motor pulse period of 1 second. The digital adjustment (inhibition) can clearly be seen at a 60 s time intervals. Ensure that the selected measuring time is correct in order to get an accurate measuring result. A 2 s measuring time is sufficient for quartz watches which were adjusted with a trimmer or a chip capacitor. Nowadays most quartz watches are adjusted with the inhibition process (programming). In most cases the inhibition time is 60 s. The measuring time must correspond to the inhibition time or be a multiple of it. The number and name of the program is also displayed. Witschi Electronic Ltd Chronoscope M1 Page 33

34 9 CONNECTING A PC 9.1 APPLICATION The PC-Software SyncM1-PRO allows the bi-directional synchronization of the data's. This signifies that the complete configuration of the equipment (system- and measuring parameters) can be transferred to the PC, or reverse, from the PC to the equipment. You may also easy and quickly edit the parameters with the PC. In addition the software allows long time tracing of rate and amplitude, visualizing of the beat noises and a mode for saving the numerical results of serial measurements of watches. By setting a password you may lock all editing possibilities of the parameters. 9.2 INSTALLATION Switch off the Chronoscope M1 and the PC before connecting! Connect the equipment by means of a 9-pin Link Cable to the PC port (COM1 or COM2). Consult the manual for installation and operating the software. 10 Disposal of the Instrument This electronic instrument should not be disposed of as household refuse. If it is not accepted by public collecting points, kindly bring it back to the sales outlet. It will provide suitable disposal according to legal directives. Your equipment suppliers in the EU will take back free of charge all instruments manufactured after the , as well as an older instrument provided an equivalent new instrument is purchased. Page 34 Chronoscope M1 Witschi Electronic Ltd

35 11 MAINTENANCE CHRONOSCOPE M1 does not require any special maintenance. Only use a soft cloth to remove the dirt; do not use aggressive detergents or solvents. Clean the LCD display with a lightly moistened cloth. Disconnect the power supply during longer idle periods of time (e.g. vacations). Protect the instrument from dirt with its specific dust-proof cover when you do not use it. To keep measurements accurate we recommend contacting our customer service in order to have your instrument calibrated and its functionality checked yearly. When the device is connected to the GPS receiver (available as accessory) you can test the calibration and, if necessary, re-calibrate the device. Make sure that the GPS signal reception is free from disturbances. Then proceed as follows: - Make sure that the ref: parameter is set up as GPS in the System parameters menu. - Select the parameter time base and press briefly the knob. Then following message appears: verify adjust cancel - If you choose verify and press the knob, the quartz time base will now be compared to the GPS signal. The alternating appearance of the arrows confirms that the measurement is carried out. After a few seconds the deviation of the time base will be displayed in a resolution of 1/1000 s/d. - If you choose adjust and press the knob, the quartz time base will now be compared to the GPS signal. The alternating appearance of the arrows confirms that the calibration is carried out. After a few seconds the calibration is done. The frequency, the correction (d) as well as the correction of the previous calibration (d) will be displayed. - The date of the last calibration will also be updated. - Now press the turning knob to quite the calibration mode. Witschi Electronic Ltd Chronoscope M1 Page 35

36 If you do not have any GPS receiver, make sure to carry out the calibration with an appropriate signal transmitter which must be connected to an accurate frequency generator. Do not hesitate to contact customer service at our headquarters or one of our agencies if you require more information. Caution! Inappropriate calibration will impair the accuracy of the instrument. Page 36 Chronoscope M1 Witschi Electronic Ltd

37 12 TECHNICAL DATA Measurements: rate deviation, beat error and amplitude of mechanical watches, diagram of watch beats. Rate deviation of quartz watches by means of a built-in signal transducer (capacitive/magnetic). Number of beats: automatic evaluation of all usual numbers of beats. Manual setting up of a required number of beats according to the range: to b/h. Determination of an unknown number of beats. Gain control: automatic. The gain can be manually adjusted to correct for secondary noises or abnormal noises in watches. Diagram: drawn on LCD display with a resolution of 640 x 200 points. Time scale selectable from 1 mm/ms to 10 mm/ms. Charting velocity: depending on the number of beats, can be set up from 0.3 to 0.04 mm per watch beat. Visible diagram length: 210 mm. Trace mode: simultaneously displays the deviation rate and the amplitude as a function of time. Measuring time for numerical results: auto = current display or selectable from 2 s to 240 s. Continuous averaging over the measuring time computed every 2 s. Screen display of the computed diagram section showing the rate measurement. Measurement of the rate deviation: numerical display in s/d. Resolution selectable in 1 s/d or 1/10 s/d. Measuring range: +/- 999 s/d, or +/ s/d. Accuracy: +/- 0.1 s/d. Vibration amplitude: numerical display in degrees. Resolution 1, measuring range from 60 to 360. Lift angle can be set up from 10 to 90. The lift angle can be off when only the rate is to be measured. Accuracy: +/ Beat error: numerical display in milliseconds. Resolution 0.1 ms, measuring range +/- 9.9 ms. Accuracy: +/- 0.1 ms. Oscillogram: diagram shows beat noises to enable analysis of the escapement. Non-linear signal gain allowing a better visualization of small signal amplitudes. Automatic gain adjustment for full-screen display. 3 different time-base sweeps: 20 ms, 200 ms and 400 ms covering the entire screen length. Acoustic check: built-in loudspeaker which reproduces the beat noise. Measurements of quartz watches: Measuring time: auto = current display (automatic setting up at 60s measuring time for watches adjusted with the inhibition process) also selectable from 2 s to 480 s. Resolution 0.01 s/d, measuring range +/- 9.9 s/d as well as resolution 1 s/month, measuring range +/- 300 s/month. start/stop function: the current display can be stopped at any time to carry out a deeper analysis. Witschi Electronic Ltd Chronoscope M1 Page 37

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1 Content 1. Company Profile... 3 2. Product Introduction... 3 3. Operation Instruction...

More information

Operating Manual B 300

Operating Manual B 300 Greiner vibrograf A.G. Mittelstrasse 2 CH - 4900 Langenthal Switzerland Tel. ++41 62 923 44 33 Fax ++41 62 923 18 46 info@greinervibrograf.ch www.greinervibrograf.com B 300 MANUAL Operating Manual B 300

More information

EDL8 Race Dash Manual Engine Management Systems

EDL8 Race Dash Manual Engine Management Systems Engine Management Systems EDL8 Race Dash Manual Engine Management Systems Page 1 EDL8 Race Dash Page 2 EMS Computers Pty Ltd Unit 9 / 171 Power St Glendenning NSW, 2761 Australia Phone.: +612 9675 1414

More information

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT Universal Control Unit UC-1-E User Manual General Information Universal Control Unit UC-1 Of Central Lubrication CC DC 24 V 5A / M 15 SL /MK 31 M Z 30 General Information Contents Universal Control Unit

More information

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor Touch Display LCD Monitor User Manual Installation Guide 15 Resistive Touch LCD Monitor MODEL: KK1500-TR i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com User

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

Topic: Instructional David G. Thomas December 23, 2015

Topic: Instructional David G. Thomas December 23, 2015 Procedure to Setup a 3ɸ Linear Motor This is a guide to configure a 3ɸ linear motor using either analog or digital encoder feedback with an Elmo Gold Line drive. Topic: Instructional David G. Thomas December

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

SNG-2150C User s Guide

SNG-2150C User s Guide SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120

More information

PXL2760MW LED LCD Monitor

PXL2760MW LED LCD Monitor PXL2760MW LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 Package Overview...3 First Setup...4 Front View of the Product...5 Rear View of the Product...6

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

PXL2470MW LED LCD Monitor

PXL2470MW LED LCD Monitor PXL2470MW LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Unpacking Instructions...2 Safety Precautions...2 Package Overview...3 First Setup...4 Front View of the Product...5

More information

013-RD

013-RD Engineering Note Topic: Product Affected: JAZ-PX Lamp Module Jaz Date Issued: 08/27/2010 Description The Jaz PX lamp is a pulsed, short arc xenon lamp for UV-VIS applications such as absorbance, bioreflectance,

More information

22" Touchscreen LED Monitor USER'S GUIDE

22 Touchscreen LED Monitor USER'S GUIDE 22" Touchscreen LED Monitor USER'S GUIDE Content Operation Instructions...1 Unpacking Instructions...2 Safety Precautions...2 Front View of the Product...3 Rear View of the Product...4 Quick Installation...5

More information

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller RF Mogul Satellite Dish Controller Model: SDC1 Quick Start 29 February 2012 Minimum required hardware to find a Satellite! This Quick Start document is for connecting and operating a General Dynamics C125M

More information

DCL9AW. User Manual. English

DCL9AW. User Manual. English DCL9AW User Manual English PRECAUTIONS Information for users applicable in European Union countries 1 Information for users applicable in United States of America 1 Installation 1 Power connection 1 Maintenance

More information

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie. Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin,

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar

More information

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module Introduction The vibration module allows complete analysis of cyclical events using low-speed cameras. This is accomplished

More information

E X P E R I M E N T 1

E X P E R I M E N T 1 E X P E R I M E N T 1 Getting to Know Data Studio Produced by the Physics Staff at Collin College Copyright Collin College Physics Department. All Rights Reserved. University Physics, Exp 1: Getting to

More information

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly. Table of Contents Introduction...3 Safety Information...4-6 Before Beginning Installation...7 Installation Guide...8 Wiring Camera & Monitor...9-10 Replacement Installation Diagram...11 Clip-On Installation

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS USER MANUAL 27 Full HD Widescreen LED Monitor L27ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE ? 8 LCD Screen? 10.4 LCD Screen LCD Zoom Microscope Instruction Manual Please read the Instruction Manual carefully before installation and keep it for future

More information

WELDING CONTROL UNIT: TE 450 USER MANUAL

WELDING CONTROL UNIT: TE 450 USER MANUAL j WELDING CONTROL UNIT: TE 450 USER MANUAL RELEASE SOFTWARE No. 1.50 DOCUMENT NUMBER: MAN 4097 EDITION: MARCH 1998 This page is left blank intentionally. 2 / 34 TABLE OF CONTENTS SUBJECTS PAGE WELDING

More information

Experiment 9A: Magnetism/The Oscilloscope

Experiment 9A: Magnetism/The Oscilloscope Experiment 9A: Magnetism/The Oscilloscope (This lab s "write up" is integrated into the answer sheet. You don't need to attach a separate one.) Part I: Magnetism and Coils A. Obtain a neodymium magnet

More information

PL2410W LCD Monitor USER'S GUIDE.

PL2410W LCD Monitor USER'S GUIDE. PL2410W LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

PLL2710W LED LCD Monitor

PLL2710W LED LCD Monitor PLL2710W LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 Package Overview...3 First Setup...4 Front View of the Product...5 Rear View of the Product...6

More information

PLL2210MW LED Monitor

PLL2210MW LED Monitor PLL2210MW LED Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a

More information

Dell D3218HN. User s Guide. Regulatory model: D3218HNo

Dell D3218HN. User s Guide. Regulatory model: D3218HNo Dell D3218HN User s Guide Regulatory model: D3218HNo Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

32" LED Television. Initial Assembly B. Main Unit. 1. Fix the Left Base Stand to the main unit using 2 pcs provided screws.

32 LED Television. Initial Assembly B. Main Unit. 1. Fix the Left Base Stand to the main unit using 2 pcs provided screws. 2 3 4 8047922B 32" LED Television Initial Assembly 8047922 Main accessories: Installation Steps: 1. Fix the Left Base Stand to the main unit using 2 pcs provided screws. 2. Fix the Right Base Stand to

More information

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope Quick Start RSHS1000 Series Handheld Digital Oscilloscope General Safety Summary Carefully read the following safety precautions to avoid personal injury and prevent damage to the instrument or any products

More information

PLL1920M LED LCD Monitor

PLL1920M LED LCD Monitor PLL1920M LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Installation...6

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B ) SMARTSCAN 8000 PLUS LIGHT CURTAIN 1 Unpacking 8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/0160306 CD206B160306 ) Remove all packaging material and retain it Locate and keep the delivery

More information

C. 48" LED Television FLD C. 6 machine x12 Screws

C. 48 LED Television FLD C. 6 machine x12 Screws 2 3 4 8012422C 48" LED Television FLD4800 8012422C 6 6 machine x12 Screws 5 6 7 8 1 18 2 3 4 5 19 20 21 6 7 8 9 10 22 23 24 25 11 12 13 14 15 16 26 27 28 29 30 31 32 33 17 9 I I II 10 11 12 13 14 15 4-digit

More information

Precision testing methods of Event Timer A032-ET

Precision testing methods of Event Timer A032-ET Precision testing methods of Event Timer A032-ET Event Timer A032-ET provides extreme precision. Therefore exact determination of its characteristics in commonly accepted way is impossible or, at least,

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Complete Fine Beam Tube System 1013843 Instruction sheet 10/15 SD/ALF If it is to be expected that safe operation is impossible (e.g., in case of visible damage), the apparatus is

More information

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL. 22 Class Slim HD Widescreen Monitor L215DS USER MANUAL 22" Class Slim HD Widescreen Monitor L215DS TABLE OF CONTENTS 1 Getting Started Package Includes Installation 2 Control Panel / Back Panel Control Panel Back Panel 3 On Screen Display 4 Technical

More information

KNX Dimmer RGBW - User Manual

KNX Dimmer RGBW - User Manual KNX Dimmer RGBW - User Manual Item No.: LC-013-004 1. Product Description With the KNX Dimmer RGBW it is possible to control of RGBW, WW-CW LED or 4 independent channels with integrated KNX BCU. Simple

More information

STX Stairs lighting controller.

STX Stairs lighting controller. Stairs lighting controller STX-1795 The STX-1795 controller serves for a dynamic control of the lighting of stairs. The lighting is switched on for consecutive steps, upwards or downwards, depending on

More information

26 Inch CGA/EGA/VGA/DVI to WXGA/1080p LCD - ID#703

26 Inch CGA/EGA/VGA/DVI to WXGA/1080p LCD - ID#703 26 Inch CGA/EGA/VGA/DVI to WXGA/1080p LCD - ID#703 Operation Manual Introduction This monitor is an open frame LCD Panel monitor. It features the VESA plug & play system which allows the monitor to automatically

More information

BLUNIK II ACCESSORIES SPORT DRIVE SPORT CALCULATOR... 49

BLUNIK II ACCESSORIES SPORT DRIVE SPORT CALCULATOR... 49 USER GUIDE 12/2016 2 INDEX DESCRIPTION of BLUNIK II...6 DESCRIPTION of parameters...7 ADJUSTMENT OF PARAMETERS...7 Parameter: CLOCK SYNCHRO...8 Parameter: TIRES...9 Parameter: CALIBRATION... 10 Calibration

More information

It will cause malfunction if the monitor is operating with unspecified power supply

It will cause malfunction if the monitor is operating with unspecified power supply User Manual / Installation Guide Model No. PTM-1525R/RT Warning! It will cause malfunction if the monitor is operating with unspecified power supply unit or incorrect power voltage. Do not exposure this

More information

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition

More information

Pre-processing of revolution speed data in ArtemiS SUITE 1

Pre-processing of revolution speed data in ArtemiS SUITE 1 03/18 in ArtemiS SUITE 1 Introduction 1 TTL logic 2 Sources of error in pulse data acquisition 3 Processing of trigger signals 5 Revolution speed acquisition with complex pulse patterns 7 Introduction

More information

MICROMASTER Encoder Module

MICROMASTER Encoder Module MICROMASTER Encoder Module Operating Instructions Issue 01/02 User Documentation Foreword Issue 01/02 1 Foreword Qualified Personnel For the purpose of this Instruction Manual and product labels, a Qualified

More information

HulaMixer Sample Mixer

HulaMixer Sample Mixer USER GUIDE HulaMixer Sample Mixer Catalog Number 15920D Publication Number MAN0014597 Revision A.0 For Research Use Only. Not for use in diagnostic procedures. For Research Use Only. Not for use in diagnostic

More information

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015 TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V1.2-1.4 January 2015 A display and command module for the Trimble Thunderbolt GPS with 10MHz reference oscillator. by Hubbatech Software Revision Notes: 1.2-2014

More information

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD TECHNICAL MANUAL AF-166 INSTRUMENT CALIBRATION FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM 9390-6000-34 FREQUENCY STANDARD THIS PUBLICATION SUPERSEDES NAVAIR 17-20AF-166 DATED 1 FEBRUARY 2005 DISTRIBUTION

More information

Knocking detector device DENOX 2, DENOX 20. User guide. HW & SW versions, December 2006

Knocking detector device DENOX 2, DENOX 20. User guide. HW & SW versions, December 2006 Knocking detector device DENOX 2, DENOX 20 HW & SW versions, December 2006 User guide Copyright 2006 ComAp s.r.o. Prague, Czech Republic ComAp, spol. s r.o. Světova 7, 180 00 Praha 8, Czech Republic Tel:

More information

USER MANUEL. SNIPE 2 Ref R13

USER MANUEL. SNIPE 2 Ref R13 USER MANUEL SNIPE 2 Ref. 0141317R13 Contents 1. General Information 1-1. Introduction 1-2. Proper use and operation 1-3. Safety notes......... 2 3 3 2. Contents 2-1. Accessory included 2-2. Name of parts......

More information

TV Synchronism Generation with PIC Microcontroller

TV Synchronism Generation with PIC Microcontroller TV Synchronism Generation with PIC Microcontroller With the widespread conversion of the TV transmission and coding standards, from the early analog (NTSC, PAL, SECAM) systems to the modern digital formats

More information

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor True FLAT P-CAP LCD Monitor User Manual Installation Guide 15 True FLAT P-CAP Touch LCD Monitor MODEL: KKF1500-PCAP i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com

More information

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL Full HD Widescreen LED Monitor L215ADS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

USER MANUAL Full HD Widescreen LED Monitor L236VA

USER MANUAL Full HD Widescreen LED Monitor L236VA USER MANUAL 23.6 Full HD Widescreen LED Monitor L236VA TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & & Exercise 4-2 EXERCISE OBJECTIVE To describe the operation of an electrical counter; To assemble and test a continuous reciprocation system; To extend and retract a cylinder a definite number of times using

More information

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Reference. TDS7000 Series Digital Phosphor Oscilloscopes Reference TDS7000 Series Digital Phosphor Oscilloscopes 07-070-00 0707000 To Use the Front Panel You can use the dedicated, front-panel knobs and buttons to do the most common operations. Turn INTENSITY

More information

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide GB05-7 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2013 In the interests of development, information

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

True RMS AC/DC Mini Clamp Meter

True RMS AC/DC Mini Clamp Meter User's Guide True RMS AC/DC Mini Clamp Meter Model 380947 Introduction Congratulations on your purchase of the Extech 380947 True RMS Clamp Meter. This Clamp meter measures current up to 400A DC/AC and

More information

FRQM-2 Frequency Counter & RF Multimeter

FRQM-2 Frequency Counter & RF Multimeter FRQM-2 Frequency Counter & RF Multimeter Usage Instructions Firmware v2.09 Copyright 2007-2011 by ASPiSYS Ltd. Distributed by: ASPiSYS Ltd. P.O.Box 14386, Athens 11510 (http://www.aspisys.com) Tel. (+30)

More information

USER MANUAL Full HD Widescreen LED Monitor L215IPS

USER MANUAL Full HD Widescreen LED Monitor L215IPS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215IPS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

Temperature recorder with display and built-in printer Instruction manual

Temperature recorder with display and built-in printer Instruction manual T-PRINT G0221E T-PRINT G0241 Temperature recorder with display and built-in printer Instruction manual CONTENT 1.0 BASIC RECORDER FEATURES...3 2.0 FIXED INSTALLATION OF RECORDER...3 3.0 RECORDER CONFIGURATION

More information

Technical data. General specifications. Indicators/operating means

Technical data. General specifications. Indicators/operating means Model Number Single head system Features Sensor head bidirectional and rotatable Function indicators visible from all directions Quick mounting bracket Selectable sound lobe width Programmable Diagrams

More information

LedSync820C LED Video Processor USER S MANUAL

LedSync820C LED Video Processor USER S MANUAL LedSync820C LED Video Processor USER S MANUAL TABLE OF CONTENTS I. Safety precautions ----------------------------------------------------------------- 3 II. Connections of hardware 1.Rear view ------------------------------------------------------------

More information

Universal DiSEqC controller USER MANUAL

Universal DiSEqC controller USER MANUAL Universal USER MANUAL SAT CONTROL 1. INTRODUCTION Satellite television is one of most favourite and popular medium in today s world. But reception 36.000 km away from the sky is more technically difficult.

More information

Universal DiSEqC controller USER MANUAL SAT CONTROL

Universal DiSEqC controller USER MANUAL SAT CONTROL USER MANUAL SAT CONTROL SAT CONTROL Dear customer, If you have not been able to put the system into operation or have problems installing it, call the Technical Assistance phone as indicated on the first

More information

LCD VALUE SERIES (32 inches)

LCD VALUE SERIES (32 inches) LCD VALUE SERIES (32 inches) http://www.orionimages.com All contents of this document may change without prior notice, and actual product appearance may differ from that depicted herein 1. SAFETY INSTRUCTION

More information

LA1500R USER S GUIDE.

LA1500R USER S GUIDE. LA1500R USER S GUIDE www.planar.com The information contained in this document is subject to change without notice. This document contains proprietary information that is protected by copyright. All rights

More information

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV REV. 1.0 Fully ly Automaticti Motorised Satellite t TV System User s manual Customer Help Line: 1300 139 255 Support Email: support@satkingpromax.com.au Website: www.satkingpromax.com.au www.satkingpromax.com.au

More information

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S INSTRUCTIONS FOR USE Pro-Ject Tuner Box S Dear music lover, thank you for purchasing a Pro-Ject Audio Systems FM-tuner. In order to achieve maximum performance and reliability you should study these instructions

More information

Auxiliary states devices

Auxiliary states devices 22 Auxiliary states devices When sampling using multiple frame states, Signal can control external devices such as stimulators in addition to switching the 1401 outputs. This is achieved by using auxiliary

More information

VSP 168HD Quick Start

VSP 168HD Quick Start VSP 168HD Quick Start Support 10Gbps of transmission rate Support HDBaseT protocols and standards Support USB upgrade Max 2048 1152@60Hz/2560 816 60Hz input/output resolution Support custom output resolution

More information

Winmate Communication INC.

Winmate Communication INC. 20.1 Military Grade Display Model: R20L100-RKA2ML User s Manual Winmate Communication INC. May, 2011 1 IMPORTANT SAFETY INSTRUCTIONS Please read these instructions carefully before using the product and

More information

Metal Electrode Meter

Metal Electrode Meter Metal Electrode Meter INSTRUCTION MANUAL FOR Metal Electrode Meter MODEL 2900 Serial # Date PO Box 850 Carlsborg, WA 98324 U.S.A. 360-683-8300 800-426-1306 FAX: 360-683-3525 http://www.a-msystems.com Version

More information

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500 Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B

More information

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

17 19 PROFESSIONAL LCD COLOUR MONITOR ART 17 19 PROFESSIONAL LCD COLOUR MONITOR ART. 41657-41659 Via Don Arrigoni, 5 24020 Rovetta S. Lorenzo (Bergamo) http://www.comelit.eu e-mail:export.department@comelit.it WARNING: TO REDUCE THE RISK OF FIRE

More information

The BAT WAVE ANALYZER project

The BAT WAVE ANALYZER project The BAT WAVE ANALYZER project Conditions of Use The Bat Wave Analyzer program is free for personal use and can be redistributed provided it is not changed in any way, and no fee is requested. The Bat Wave

More information

SIMET AVIKO D INSTRUCTION MANUAL SORTING Solutions, Ltd.

SIMET AVIKO D INSTRUCTION MANUAL SORTING Solutions, Ltd. SIMET AVIKO D INSTRUCTION MANUAL 1870 SORTING Solutions, Ltd. 1. TABLE OF CONTENTS 1. TABLE OF CONTENTS...1 2. INTRODUCTION...2 2.1. Application...2 2.2. Operating Conditions...2 2.3. Electro - Optical

More information

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix v1.2 Burlington County College INSTRUCTION GUIDE for the Hewlett Packard FUNCTION GENERATOR Model #33120A and Tektronix OSCILLOSCOPE Model #MSO2004B Summer 2014 Pg. 2 Scope-Gen Handout_pgs1-8_v1.2_SU14.doc

More information

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s ET 150 Scope Controls Learning Objectives In this lesson you will: learn the location and function of oscilloscope controls. see block diagrams of analog and digital oscilloscopes. see how different input

More information

Event recording (or logging) with a Fluke 287/289 Digital Multimeter

Event recording (or logging) with a Fluke 287/289 Digital Multimeter Event recording (or logging) with a Fluke 287/289 Digital Multimeter Application Note One of the major features of the Fluke 280 Series digital multimeters (DMM) with TrendCapture is their ability to record

More information

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk

More information

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP SINGLE/TWO CHANNEL 24HR/7 DAY TIMER Cat No. TR671/TR672TOP INSTALLATION & OPERATING INSTRUCTIONS TR671/TR672TOP 24Hr/7 Day 1/2 Channel Digital TOP Module (without Power Supply) Please read the instructions

More information

R&S ZVA110 Vector Network Analyzer Specifications

R&S ZVA110 Vector Network Analyzer Specifications ZVA110_dat-sw_en_5214-4813-22_cover.indd 1 Data Sheet 04.00 Test & Measurement R&S ZVA110 Vector Network Analyzer Specifications 15.11.2013 14:42:28 CONTENTS Definitions... 3 Specifications... 4 Overview...

More information

HSR-1 Digital Surveillance Recorder Preliminary

HSR-1 Digital Surveillance Recorder Preliminary HSR-1 Digital Surveillance Recorder Hybrid Technology - An Essential Requirement for High-Performance Digital Video Recording & Archiving Preliminary How do you rate your security Can it record as long

More information

D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER. User s Guide (Please read carefully before using for the first time!)

D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER. User s Guide (Please read carefully before using for the first time!) D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER User s Guide (Please read carefully before using for the first time!) Copyright 2018 by ASPiSYS Ltd. DRMAX2 is a low-power DRM MW transmitter.

More information

DH551C/DH550C/DL550C Double Sided Display User Manual

DH551C/DH550C/DL550C Double Sided Display User Manual DH551C/DH550C/DL550C Double Sided Display User Manual Disclaimer BenQ Corporation makes no representations or warranties, either expressed or implied, with respect to the contents of this document. BenQ

More information

NS-3 RF Noise Source Operation Manual

NS-3 RF Noise Source Operation Manual RF Noise Source Operation Manual Version 2.04 June 3, 2016 SPECIFICATIONS Frequency... Maximum output level... Output flatness... (at max output level) Impedance... Displayed level... Repeatability...

More information

HD-CM HORIZON DIGITAL CABLE METER

HD-CM HORIZON DIGITAL CABLE METER HD-CM OFF! Max RF i/p = +17dBm 75Ω Max AC/DC i/p = 120Vrms MENU INPUT ON HORIZON DIGITAL CABLE METER Horizon Global Electronics Ltd. Unit 3, West Side Flex Meadow Harlow, Essex CM19 5SR Phone: +44(0) 1279

More information

Hardware & software Specifications

Hardware & software Specifications Hardware & software Specifications Réf : PRELIMINARY JUNE 2007 Page 2 of 17 1. PRODUCT OVERVIEW...3 2. TERMINOLOGY...4 A. THE FRONT PANEL...4 B. THE REAR PANEL...5 3. SCREENS DESCRIPTION...5 A. MAIN SCREEN

More information

Indoor/Outdoor Security System with Quad Monitor User s Manual

Indoor/Outdoor Security System with Quad Monitor User s Manual Indoor/Outdoor Security System with Quad Monitor User s Manual 4919539 Important! Please read this booklet carefully before installing or using these units. WARNING - These units should ONLY be opened

More information

The Measurement Tools and What They Do

The Measurement Tools and What They Do 2 The Measurement Tools The Measurement Tools and What They Do JITTERWIZARD The JitterWizard is a unique capability of the JitterPro package that performs the requisite scope setup chores while simplifying

More information

VGA to DVI Extender over Fiber SET

VGA to DVI Extender over Fiber SET VGA to DVI Extender over Fiber SET Model #: FO-VGA-DVI 2011 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview ) products. Avenview

More information

TFT LCD MONITOR USER MANUAL. L80AP and L101AP

TFT LCD MONITOR USER MANUAL. L80AP and L101AP TFT LCD MONITOR USER MANUAL L80AP - 8.0 and L101AP - 10.1 Table Of Contents Table of contents/ Warning.... 2 Precautions...3 About this user manual and products / Items included in the delivery..... 4

More information

Hex-color RGBAW+UV LED strip light

Hex-color RGBAW+UV LED strip light Hex-color RGBAW+UV LED strip light 2 19 SAFETY / GENERAL INSTRUCTIONS INTRODUCTION Features Specifications OVERVIEW : CONNECTIONS Rear view DIMENSIONS INSTALLATION Mounting FUNCTIONS AND SETTINGS Function

More information

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России) 127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) 322-99-34 +7 (800) 200-74-93 (бесплатно на территории России) E-mail: info@awt.ru, web:www.awt.ru Contents 1 Introduction...2

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E