1 Operating manual Antenna Measuring System MSK 125(/MR) From software version V1.4

2 FOREWORD/IMPORTANT INSTRUCTIONS Dear customer, thank you for choosing the Kathrein MSK 125 measuring device. Please read the following instructions carefully, so as to familiarise yourself with all the new functions before starting to use your instrument. Please comply with all the instructions in this operating manual. KATHREIN-Werke KG has done all it can to ensure that the data and descriptions in this operating manual are correct and complete. We reserve the right to make changes without notice. In particular, this applies to changes made due to technical advancements. We would be pleased to receive any suggestions for improvements. All product names and brands used in this operating manual are the property of their respective owners. VALIDITY OF THIS OPERATING MANUAL This operating manual is applicable to the MSK 125 measuring device, article no.: and MSK 125/MR, article no.: The following instructions are important for operating the measuring device and should be complied with under all circumstances. GENERAL SAFETY INSTRUCTIONS The MSK 125 has been developed and manufactured in compliance with all relevant harmonised directives, standards and other technical specifi cations. The product is stateof-the-art and offers a high level of safety. This degree of safety can however be achieved in operation only if the user complies with all necessary safety regulations. Electronic equipment is not household waste - in accordance with directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL dated 27 th January 2003 on used electrical and electronic equipment, it must be disposed of properly. At the end of its service life, take this device for disposal at a designated public collection point. Spent batteries are special waste! Do not throw spent batteries into your domestic waste; take them to a collection point for old batteries! 2

3 CONTENTS FOREWORD/IMPORTANT INSTRUCTIONS... 2 CONTENTS... 3 SAFETY INSTRUCTIONS... 6 FUNCTIONALITY... 7 OPERATING AND DISPLAY ELEMENTS... 9 CONNECTIONS SET-UP MAINS AND BATTERY OPERATION POWER UP POWER DOWN SETUP MENU CLOCK (FROM SERIAL NO MSK 125 AND MSK 125MR) SAT ANALOGUE SATELLITE RECEPTION SAT ANALOGUE/DVB-S(2) SELECTION FREQUENCY DISPLAY AND ENTRY COMMAND OVERVIEW OF SAT FREQUENCY INPUT SAT TRANSPONDER FREQUENCY INPUT LNB VOLTAGE AND 22 KHZ SELECTION SAT ANALOGUE LEVEL MEASUREMENT SOUND CARRIER FREQUENCY SETTING DIGITAL SAT RECEPTION FREQUENCY DISPLAY AND ENTRY COMMAND OVERVIEW OF SAT FREQUENCY INPUT SAT DVB-S(2) LEVEL MEASUREMENT SETTING DVB-S(2) DEMODULATION PARAMETERS DVB-S(2) MER, BER AND OFFSET MEASUREMENT MPEG IMAGE REPRESENTATION IN DVB-S(2) NIT NETWORK INFORMATION TABLE WITH DVB-S (S2) DISEQC TM (DIGITAL SATELLITE EQUIPMENT CONTROLLER) STRUCTURAL ARRANGEMENT OF THE DISEQC TM CONTROLLER SIGNAL COMMAND OVERVIEW FOR DISEQC TM COMMAND OVERVIEW FOR THE FRAMING BYTE COMMAND OVERVIEW FOR THE ADDRESS BYTE COMMAND OVERVIEW FOR THE COMMAND BYTE COMMAND OVERVIEW FOR THE DATA BYTE SCIF/SCR SINGLE CABLE INTERFACE (SAT SINGLE CABLE SYSTEM DISEQC CONTROLLER).. 38 SIMPLE DISEQC TM, TONE BURST COMMAND OVERVIEW FOR SIMPLE DISEQC TM LOCATING SATELLITES FINDING INDIVIDUAL RECEPTION FREQUENCIES TV MEASUREMENT ANALOGUE CABLE TV RECEPTION ANALOGUE CABLE/DVB-C SELECTION

4 CONTENTS 4 RF STANDARD SELECTION - ANALOGUE CABLE (DEMOD MENU) CHANNEL DISPLAY AND ENTRY COMMAND OVERVIEW FOR INPUT TV CHANNEL FREQUENCY DISPLAY AND ENTRY COMMAND OVERVIEW FOR TV FREQUENCY INPUT CABLE ANALOGUE LEVEL MEASUREMENT LEVEL OVERFLOW AND UNDERFLOW AUDIO CARRIER SPACING AND LEVEL COMMAND OVERVIEW FOR MEASURE TV AUDIO CARRIER FREQUENCY DIGITAL CABLE TV RECEPTION ANALOGUE CABLE/DVB-C SELECTION CHANNEL DISPLAY AND ENTRY COMMAND OVERVIEW FOR TV CHANNEL ENTRY FREQUENCY DISPLAY AND ENTRY COMMAND OVERVIEW FOR TV FREQUENCY INPUT SETTING DVB-C DEMODULATION PARAMETERS LEVEL MEASUREMENT OF DVB-C SIGNALS ANALOGUE CABLE/DVB-C SELECTION DVB-C MER, BER AND OFFSET MEASUREMENT MPEG IMAGE REPRESENTATION IN DVB-C NIT NETWORK INFORMATION TABLE FOR DVB-C ANALOGUE TERRESTRIAL TV RECEPTION ANALOGUE TERRESTRIAL / DVB T/H SELECTION RF STANDARD SELECTION RF STANDARD SELECTION CHANNEL DISPLAY AND ENTRY COMMAND OVERVIEW FOR INPUT TV CHANNEL FREQUENCY DISPLAY AND ENTRY COMMAND OVERVIEW FOR TV FREQUENCY INPUT DIGITAL TERRESTRIAL TV RECEPTION ANALOGUE TERRESTRIAL / DVB T/H SELECTION SETTING DVB-T/H DEMODULATION PARAMETERS RF STANDARD SELECTION DVB-T CHANNEL DISPLAY AND ENTRY COMMAND OVERVIEW FOR INPUT TV CHANNEL FREQUENCY DISPLAY AND ENTRY COMMAND OVERVIEW FOR TV FREQUENCY INPUT DVB-T-/H MER, BER AND OFFSET MEASUREMENT MPEG IMAGE REPRESENTATION IN DVB-T NIT NETWORK INFORMATION TABLE FOR DVB-T REMOTE POWER FEED FOR DVB-T FINDING INDIVIDUAL RECEPTION FREQUENCIES NICAM AUDIO BIT ERROR RATE MEASUREMENT TV RETURN PATH MEASUREMENT FM MEASUREMENT FM SELECTION FREQUENCY DISPLAY AND ENTRY COMMAND OVERVIEW FOR FM FREQUENCY INPUT... 67

5 CONTENTS LEVEL MEASUREMENT LEVEL OVERFLOW AND UNDERFLOW FINDING INDIVIDUAL RECEPTION FREQUENCIES COMMAND OVERVIEW FOR FIND SPECTRUM MEASUREMENT SAT SPECTRUM TV SPECTRUM RETURN PATH SPECTRUM FM SPECTRUM STORING DEVICE SETTINGS STORING DEVICE SETTINGS RESTORING DEVICE SETTINGS DELETING DEVICE SETTINGS STORING MEASUREMENT RESULTS STORING MEASUREMENT RESULTS IN THE DEVICE MEMORY RESTORING MEASUREMENT RESULTS FROM THE DEVICE MEMORY DELETING MEASUREMENT RESULTS FROM THE DEVICE MEMORY STORING MEASUREMENT RESULTS ON THE SD CARD DATA LOGGER ENTERING THE START AND STOP LINE FOR AUTOMATIC MEASURING ENTERING THE START LINE FOR AUTOMATIC MEASURING ENTERING THE STOP LINE FOR AUTOMATIC MEASURING STARTING AND INTERRUPTING AUTOMATIC MEASURING RESTORING MEASUREMENT RESULTS FROM THE DEVICE MEMORY STORING THE DATA LOGGER MEASUREMENT RESULTS ON THE SD CARD MAINTENANCE DEVICE CALIBRATION OUTSIDE CLEANING INTERIOR CLEANING FUNCTION TEST REQUIRED MEASURING EQUIPMENT CHANGING THE BATTERY STORAGE CUSTOMER SERVICE TECHNICAL CUSTOMER SUPPORT FEATURES TECHNICAL SPECIFICATIONS TECHNICAL APPENDIX SIGNAL-TO-NOISE RATIO DISEQC TM COMMANDS FOR KATHREIN MATRICES CHANNEL TABLES CALCULATION OF SAT IF FREQUENCY USING THE MSK

6 SAFETY INSTRUCTIONS This manual is intended for use by persons with a basic knowledge of electrics. Users who have already worked with similar measuring devices can use a command overview for the necessary commands for each operating step. Additionally, the following examples are designed to provide the individual operating steps. MEANING OF SYMBOLS Instructions which display the caution symbol must be complied with to avoid damage to the MSK 125. This symbol indicates notes for measuring functions or refers to chapters that contain further information on a topic. This symbol is followed by an example of the measurement function being explained. Provides a command overview with the relevant key combinations for the particular measuring function. Device button SAFETY INSTRUCTIONS Please follow the enclosed safety instructions. SCOPE OF SUPPLY 1 German/English operating manual 1 AC/DC power unit 1 power cable 1 BNC measuring cable 2 adapters for BNC input - F socket (one in the RF socket of the MSK 125) 1 adapter for BNC socket - F plug 1 adapter for BNC socket - IEC socket 1 adapter for BNC socket - IEC plug 1 USB cable 1 SD card (1 GB memory card) 6

7 FUNCTIONALITY The MSK 125 is a mobile multi-purpose measuring device intended for analogue TV and satellite, FM radio and for DVB-C, DVB-S(2) and DVB-T for battery and mains operation. The integrated 6.5 Ah lithium-ion battery and a rechargeable 230 V AC power unit are included in the scope of supply. A microcontroller provides all control functions, keypad polling and display of frequencies and levels on the LCD display. The reception frequency is displayed in MHz. The level is measured with a peak and mean value detector and displayed digitally in dbμv or dbmv. Correction values are determined during the MSK 125 level calibration and stored in an EEPROM. This ensures accurate level measurement. Up to 100 measuring device settings can also be stored. A second microcontroller allows you to store several thousand measurement results on an SD card or to read the SD card (up to 1GB) via USB. The display has a bar graph for transmitter location. Additionally, a level-dependent DF tone makes it possible to align an antenna without having to observe the display. The audio unit with integrated speaker can process and render SAT NF signals, the TV-NF signals of B/G, D/K and I, FM sound signals as well as DVB-C, DVB-T and DVB-S(2). NICAM and AM sound rendering (standard L) is also possible. The remote feed voltage of V/max. 600 ma (in 0.1 Volt steps), the superposition of 22 khz and the ability to transmit DiSEqC TM commands covers all currently known requirements. With DVB-T a 5 V antenna feed voltage can be received at the at the RF socket. The MZV 10 preamplifi er or similar preamplifi ers can also be fed remotely. The built-in transflective 5.7" TFT colour display with its resolution of 640 x 480 pixels allows for picture evaluation of analogue and digital TV and SAT signals in the dark as well as in sunlight. A large black and white LCD display shows the measurement results with very high contrasts. 7

8 FUNCTIONALITY Function Operating mode SAT analogue Operating mode TV analogue Operating mode FM analogue Operating mode DVB-S/S2 Operating mode DVB-C Mains and battery operated * * * * * * Operating mode DVB-T Level measurement by frequency input * * * * * * Level measurement by channel input * * * Level-dependent signal tone * * * * * * Spectrum display * * * * * * Loudspeaker for audio check * * * * * * Multi-standard reception (B/G, D/K, I, L, Nicam) Nicam audio reception and standard L * * * QPSK 8PSK QAM64, 128, 256 COFDM 2k, 8k Audio carrier setting * * Audio carrier measurement * LNB remote feed voltage supply adjustable LNB remote feed current measurement * * * * * * 22 khz switching * * * * DiSEqC, Simple DiSEqC TM * * * * * * DVB level measurement * * * DVB-MER-BER measurement * * * DVB image display * * * SCART output and input (CVBS, audio) * * * (audio only) * * * Nicam audio, reception and bit error rate measurement * Storing measurement results Storing device settings * * * * * * 8

9 OPERATING AND DISPLAY ELEMENTS Measured values and settings are shown on the LCD display. LCD DISPLAY Depending on the operating mode and function, the LCD display shows the selected channel, the selected frequency, the called function, the operating mode, the measured level and the measured values. TFT COLOUR DISPLAY LED DISPLAY Depending on the operating mode, the 5.7" TFT display shows the following: Spectrum analysis TV image Selection of digital programmes transmitted on the channel or transponder LNB and DiSEqC TM Operating voltage (battery operation = red / mains operation = green) LNB supply ((voltage = green / short circuit = green blinking) external voltage = red) 9

10 OPERATING AND DISPLAY ELEMENTS TFT Colour Display TV picture/settings Source selection Measurements On/off button Mode indicator LCD display Measurement results Settings LNB display Input pad Cursor pad 10

11 OPERATING AND DISPLAY ELEMENTS OVERVIEW OF KEYPAD COMMANDS Button Brief description of the function Switching the device on/off Sources Selection of SAT operation and switch between analogue and digital SAT Selection of cable TV operation and switch between analogue cable TV and digital cable TV Selection of terrestrial TV operation and switch between analogue terrestrial TV and digital terrestrial TV FM radio selection Selection of video/audio inputs via SCART Switch between channel and frequency input Measurements Switch on level-dependent signal tone with bar graph display Independent satellite search Spectrum analysis DVB measurement; MER, BER, OFFSET, MPEG program selection LNB power measurement and charging status display (Subcarrier) sound carrier menu, sound carrier measurement Input pad... Alphanumeric input Decimal point for digit input, DiSEqC TM hexadecimal input Special channel call 11

12 OPERATING AND DISPLAY ELEMENTS Cursor pad Decrement current values (frequency, channel, etc.) Increment current values (frequency, channel, etc.) Selection up Selection down Confi rm input or selection Reduce volume Increase volume SD card memory management Store measurement device settings and measured values Retrieve measurement device settings and measured values Settings Default settings and setting the digital modulation parameters Device settings Data logger (automatic measuring) Launch the DiSEqC TM menu LNB and remote feed voltage menu 12

13 CONNECTIONS FRONT VIEW RF input USB port SD memory card HDMI socket (only on the MSK 125/MR) Common Interface SCART (audio/video) SIDE VIEW Fan Phones RS 232 Speakers Battery fuse DC supply 13

14 CONNECTIONS RF INPUT Here the reception signal is injected from the antenna system or cable network (coaxial F socket with BNC adapter). The remote feed voltage can be adjusted from 5 V DC to 20 V DC and can also be switched off. When the LNB voltage is on, the right-hand LED lights up green. This LED fl ashes green if there is a short-circuit or overload. If an external supply is used, the LED is red. Please note that there is no voltage level over 120 dbμv, no peak voltage > 100 Volt at the RF input socket. Failure to comply with these values can damage the input circuit! USB PORT The USB port (USB 1.1) allows measurement results to be read from the inserted SD card or a software update to be performed on the slave processor. SD CARD The supplied SD memory card is used to store the measurement results. SD cards up to 1 GB max. can be used. HDMI OUTPUT The HDMI socket (only on the MSK 125/MR) on the front of the measuring device allows the digital video and audio signal to be output to an external HDMI monitor. This output is only available with digital programmes. 14

15 CONNECTIONS SCART SOCKET The video and audio signal is available at the SCART socket on the front of the MSK 125 for evaluation on an external monitor. The button also allows you to switch to audio/ video input. Incorrect connection wiring can damage the device! COMMON INTERFACE Slot for a common interface. PHONES SOCKET 3.5 mm stereo jack socket for connection of stereo headphones RS 232 INTERFACE The RS 232 port allows you to perform software updates. EXTERNAL DC SUPPLY The MSK 125 can be operated with a mains supply or on its own built-in battery. For mains operation, use the PSU and charger connected to the DC socket on the left-hand side of the MSK 125 enclosure. Use only the power supply unit supplied with the MSK

16 SET-UP BATTERY OPERATION Note Before operating the device for the fi rst time remove the T 8.0 A fuse from the packaging and place it in the fuse holder. This fuse prevents the device switching on unintentionally during transport. After the fuse has been inserted the charge status display will not function properly until the battery has been fully discharged once. Battery operation is only possible if the battery is charged sufficiently. Otherwise the MSK 125 cannot be switched on. Once the battery has fully discharged it must be recharged immediately to avoid damage to the battery. Charging starts automatically when the device is connected to the mains. A protection circuit prevents the battery from being overcharged. Battery operation is indicated by a red LED next to the button. The battery capacity is 6.45 Ah. Press the button to check the charging status of the lithium-ion battery. The LCD display shows the following values: LNB or remote feed voltage: 14.0 V LNB or remote feed current: 255 ma 22 khz switched on Battery charge status: 80 % Bar graph (8 x 10 %) Press the button again to exit this operating mode. 16

17 SET-UP MAINS AND BATTERY OPERATION MAINS OPERATION The MSK 125 can be operated with a mains supply or its own built-in battery. Remove the AC power unit supplied (100 V V) from its packaging and use it to connect the device to the mains supply. The integrated lithium-ion battery and the green LED next to the button indicate the external power supply. For mains operation use only the charger/power unit supplied. The power unit is connected to the XLR power supply socket on the left side of the device. The device should be connected to the mains supply from time to time if it not used for a while (trickle charge). Note: A 12 V vehicle supply cable can be obtained through our customer service (article no.: BF) (supplier ESC, see Customer Service for the address). DEFAULT SETUP SETTINGS AT TIME OF SHIPMENT Parameter LNB DC LEVEL LOW LEVEL MUTE Setting OFF dbμv ON 17

18 SET-UP When setting up the device ensure that adequate ventilation is provided. The openings for the fan and the ventilation holes must be kept clear at all times to avoid a build up of heat. POWER UP Confi rm the button Adjust the desired volume using the or button. The LCD display shows the current software version and the serial number of the MSK 125 for approx. 1 second. Now feed the reception signal from the receiver into the RF input socket. LCD display: channel (48) source (terrestrial) level (A = analogue level measurement; D = digital level measurement) Use the,,, and buttons to select the desired source. POWER DOWN Briefl y press the button (for about 2 seconds) to save the latest settings and automatically turn off the unit. Press the button for more than 5 seconds to turn off the device. The last settings will be lost. This action does not switch off the remote power feed. For reasons of safety this must be switched on again separately after switching on the unit. SETUP MENU Use the Setup menu to confi gure your basic settings. SETUP MENU SETTINGS To open the Setup menu: Press. Press the or buttons to switch LNB power supply 1. Setup Menu on or off. Press the button to keep the desired setting. 18

19 SET-UP In the next menu press the or button to defi ne the measurement unit in which the level will be displayed. 2. Setup Menu Press to keep the current setting. The next menu prompts you to set the mute function using the 3. Setup Menu or button. If you select ON, the MSK 125 is switched to silent as long as the incoming signal on the RF input is below 30 dbμv. Press the button to keep the desired setting. CLOCK (FROM SERIAL NO MSK 125 AND MSK 125MR) (European display) 4. Setup Menu The next menu allows you to changes the settings of the builtin clock. The date and time are loaded to the SD card when the measurement results are saved. In this menu, press the required button for at least a second in order to obtain the desired response. Press to keep the current setting. Press the button to toggle between European date format and US date format. US display Press the button to set the date and time. You can now use the numeric keys to enter successively the time and the date, and use the cursor buttons to move to another digit. The button loads the new settings and exits this menu. In the next menu you can format an SD card up to size 1 GByte. This procedure deletes any data currently on the SD card. 5. Setup Menu Press the button or the button to exit this menu. Press the button to format the SD card currently in the slot. 19

20 SAT ANALOGUE SATELLITE RECEPTION In SAT mode the MSK 125 can be set to Analogue and DVB-S(2). SAT ANALOGUE/DVB-S(2) SELECTION FREQUENCY DISPLAY AND ENTRY Press once Press again Press again = SAT analogue = DVB-S(2) = SAT analogue again To measure a reception level, fi rstly the desired frequency must be input. The LCD display indicates the frequency and the measured level. The frequency input can be set in 100 khz steps from 920 MHz to 2150 MHz, and depending on the LO frequency select the transponder frequency input can also be set from MHz to MHz. COMMAND OVERVIEW OF SAT FREQUENCY INPUT SAT-IF-(RF) input: Switching to SAT reception (analogue)... Input the frequency The frequency can be changed in 100 khz steps Confirm input Example LCD display: Frequency: MHz Operating mode: SAT Level: 66.5 dbμv A (A = analogue) Enter Frequency 1508 MHz : Press LCD display: Frequency: MHz Operating mode: SAT Level: 86.5 dbμv (A = analogue) A + or - in the display means that the MSK 125 has not been tuned accurately to the desired carrier. Use the and Note buttons to refine the frequency for optimum reception. A vertical line on the display indicates optimum frequency adjustment. Complete your frequency entry by pressing the button. The most recent frequency setting is retained even after you switch the MSK 125 off, provided it was entered with digits and confi rmed by pressing. 20

21 SAT SAT TRANSPONDER FREQUENCY INPUT Select Satellite reception (analogue or digital)... Input the frequency The frequency can be changed in 100 khz steps Confirm input Note The FRQ/CHAN button can be used to switch between SAT transponder frequency and SAT IF frequency display. To ensure that the SAT IF frequency can be correctly computed when the SAT transponder frequency is entered, prior to that the right LO frequency must be selected in the LNB Control menu. - Press the LNB Control button - Select: 2 = LO-FREQUENCY SCIF/SCR (DVB-S/S2) - Select the appropriate LNB local oscillator. Example The SAT reception frequency range of the measuring device is: 920 MHz MHz With the LO of 9750 MHz, you can receive transponders within the range: MHz MHz. With the LO of MHz, you can receive transponders within the range: MHz MHz. 21

22 SAT LNB VOLTAGE AND 22 KHZ SELECTION The LNB supply voltage is available at the RF socket. To turn on or change the LNB voltage, press the button. You will see a menu with four options: 1 = LNB-Voltage/22 khz Sets the LNB voltage and changeover between High and Low band with the 22 khz signal SCIF/SCR (DVB-S/S2) 2 = LO-Frequency Select the LNB local oscillator frequency When the transponder frequency is entered, the SAT IF frequency is computed and set with the help of the selected LO frequency. Command overview for LNB voltage 3 = Volt/Band/LO Short selection of the polarisation (H/V) of the Sat band (High/ Low band) and of the local oscillator. 4 = SCIF (Single Cable Interface)...SCR (Satellite Channel Router, also called Unicable) Programming of single cable systems, with creation and transmission of associated DiSEqC commands Select DiSEqC Controller 0= User Input 1= V/ LO-Band /Pos. 1 2= H/ LO-Band /Pos. 1 3= V/ HI-Band /Pos. 1 4= H/ HI-Band /Pos. 1 5= V/ LO-Band /Pos. 2 6= H/ LO-Band /Pos. 2 7= V/ HI-Band /Pos. 2 8= H/ HI-Band /Pos. 2 9= more 22

23 SAT Select DiSEqC Controller 0= User Input 1= V/ LO-Band /Pos. 3 2= H/ LO-Band /Pos. 3 3= V/ HI-Band /Pos. 3 4= H/ HI-Band /Pos. 3 5= V/ LO-Band /Pos. 4 6= H/ LO-Band /Pos. 4 7= V/ HI-Band /Pos. 4 8= H/ HI-Band /Pos. 4 9= more Simple-DiSEqC Commands 0= Tone Burst 1= Data Burst 9= more Menu LNB voltage : Launch the LNB menu Voltage menu... Select LNB voltage or Change LNB voltage in 0.1 V steps steps 22 khz signal on/off Exit the LNB menu The following voltages can be selected at the touch of a button: Button LNB voltage [0] 0 V [1] 12 V [2] 14 V [3] 18 V [5] 5 V [8] 22 khz 23

24 SAT For checking purposes the LED right from when the power supply is turned on. button is on Example Press the button to indicate the power consumption of the connected LNB on the display. The selectable 22 khz signal is superimposed on the LNB voltage. It is required for switching over multifeed systems or High/ Low band LNBs, for example. To select LNB voltage 14 V: Press the buttons then LCD display: LNB voltage: 14 V Current consumption: 150 ma The LNB voltage can be adjusted in 0.1 Volt steps from 5 V to 20 V (max. current 600 ma, short-circuit proof) Example Switching on the 22 khz signal Press LCD display: LNB voltage: 14 V Current consumption: 150 ma 22 khz signal switched on Note Press Press again to switch off the 22 khz signal. to exit the LNB menu. 24

25 SAT Menu: LO frequency Select the local oscillator frequency for computing the Sat IF frequency. Menu: Volt/Band/LO This function allows you to quickly select the LNB supply. All LNB settings are made automatically when you have selected the required parameters. (14V/18V; 22 khz; SAT IF calculation) Menu: SCIF/SCR (DVB-S/S2) Select SCIF/SCR type Details of this description can be found under SCIF Single Cable Interface. 1=type 1 (4REC.1LO) 2=type 2 (8REC.2LOs) 3=type 3 (4REC.2LOs) 25

26 SAT SAT ANALOGUE LEVEL MEASUREMENT Level overflow and underflow When you have selected a frequency, the level is automatically measured and appears on the LCD display as dbμv or dbmv (depending on the basic confi guration). The input level can be measured within the range 30 dbμv to 120 dbμv (-30 dbmv to 60 dbmv). LCD display: Frequency: MHz Operating mode: SAT analogue Measured level: 86.5 dbμv At a level < 30 dbμv the LCD display indicates an underflow. The following information is displayed: Frequency: MHz Operating mode: SAT analogue Level: underfl ow At a level > 120 dbμv the LCD display indicates an overflow. The following information is displayed: Frequency: MHz Operating mode: SAT analogue Level: overfl ow Note The level of DVB-S(2) signals can only be measured properly with the setting SAT digital reception. SOUND CARRIER FREQUENCY SETTING Every analogue satellite video signal is assigned a number of sound carrier frequencies. On the MSK 125 you can listen to main and sub-carriers you choose. The sound carrier frequency can be adjusted from 5.0 MHz to 8.99 MHz in 10 khz steps. At 7.00 MHz the sound carrier bandwidth is automatically switched from wide (280 khz) to narrow (150 khz). The following sound carrier frequencies are stored as factory defaults: 26

27 SAT BUTTON Frequency in MHz Bandwidth SELECT SOUND CARRIER [1] 5.80 wide Mono [2] 6.50 wide Mono [3] 6.65 wide Mono [4] 7.02 narrow [5] 7.20 narrow [6] 7.38 narrow [7] 7.56 narrow [8] 7.74 narrow [9] 7.92 narrow [0] Stereo (select left channel fi rst) Command overview for SAT audio carrier frequencies Open the sound carrier menu... Select audio carrier or Change sound carrier frequency in 10 khz steps Manually select sound carrier bandwidth wide = 280 khz, narrow = 150 khz Exit sound carrier menu Example Call the 7.38 MHz sound carrier Press Note Example LCD display: Sound sub-carrier: 7.38 MHz Sound carrier bandwidth: Narrow = 150 khz Operating mode: SAT analogue When SAT analogue mode is called the MSK 125 is always set to 7.02 MHZ sound carrier. Frequency changes to the audio carrier are only retained until you exit the SAT analogue mode. To set the headphones output to Stereo, fi rst select the desired left channel and then confi rm by pressing the 0 button. The headphones output now delivers the 7.02 and 7.20 MHz stereo sound. 27

28 SAT DIGITAL SAT RECEPTION In SAT mode the MSK 125 can be set to the Analogue and DVB-S(2) types of reception. FREQUENCY DISPLAY AND ENTRY COMMAND OVERVIEW OF SAT FREQUENCY INPUT To measure the level of an reception signal, you must first input the desired frequency. The LCD display indicates the frequency and the measured level. The frequency can be entered from 920 MHz to 2150 MHz in 100 khz steps. Select SAT reception (analogue or digital) Enter Frequency 1236 MHz : Press The frequency can be changed in 100 khz steps Then confirm the input once again LCD display: Frequency: MHz Operating mode: SAT Level: 86.5 dbμv D (D = digital) The frequency can also be input as a 5-digit transponder frequency. The appropriate LO frequency must previously have been selected. FRQ:11836 MHz LEV: 86.5dBuV Note SAT D LCD display: Frequency: MHz Operating mode: SAT Level: 86.5 dbμv (D = digital) Complete your frequency entry by pressing the button. The most recent frequency setting is retained even after you switch the MSK 125 off, provided it was entered with digits and confi rmed by pressing. 28

29 SAT SAT DVB-S(2) LEVEL MEASUREMENT SETTING DVB-S(2) DEMODULATION PARAMETERS LCD display during DVB-S(2) level measurement: Please refer to SAT analogue/dvb-s(2) selection for how to switch from analogue to digital level measurement. Frequency: MHz Operating mode: SAT digital Measured level: 86.5 dbμv (D = digital) Press to go to the symbol rate selection. Note The LCD display shows the following options: Press... to select the desired symbol rate. Press to go to the menu for USER entry of the symbol rate. Enter the desired symbol rate and complete your entry by Note pressing. If 0 Ks is entered as the User symbol rate, the symbol rate is recognised automatically. See page 22 for setting the LNB voltage and DiSEqC commands. 29

30 SAT DVB-S(2) MER, BER AND OFFSET MEASUREMENT The modulation error rate (MER), the bit error rate (BER) and the carrier frequency offset (LNB offset) can be measured to evaluate the digital reception quality. Note: MER shown on the display is synonymous with SNR (signal radio ratio) in this case. Use the SAT digital. button to select between SAT analogue and Launch DVB-S(2) measurement: In the SAT digital reception mode, press LCD display: MER modulation error rate: 12.6 db Modulation type 8PSK Code Rate 9/10 BER bit error rate: 1.7e-7 Standard = DVBS2 Trägerfrequenz-Offset (LNB-Offset): MHz MPEG IMAGE REPRESENTATION IN DVB-S(2) If the quality of the DVB signal is so good that no bit error can be detected, BER = 0.0e+0 is displayed. If you select DVB measurement by pressing, the TFT screen displays the list of programmes that can be received on the digital transport stream. Use the or key to select the desired programme and confi rm your selection by pressing. To select the programme, you can also enter the displayed programme number directly.... If the programme can be received free, the picture and sound of the desired programme are decoded and displayed and played back over the built-in speaker. By pressing the programme list. again you can select another programme from Press to exit digital reception. 30

31 SAT NIT NETWORK INFORMATION TABLE WITH DVB-S (S2) If you select DVB measurement by pressing, the TFT screen displays the list of programmes that can be received on the digital transport stream. Press the decimal point button to receive the NIT. You will receive the operator's information fi rst and the number of pages. You can now use the UP / DOWN buttons to scroll through the pages. Press the decimal point button display. again to close the NIT 31

32 SAT DISEQC TM (DIGITAL SATELLITE EQUIPMENT CONTROLLER) STRUCTURAL ARRANGEMENT OF THE DISEQC TM CONTROLLER SIGNAL The DiSEqC TM system is used to control systems with enhanced control facilities. DiSEqC TM uses a serial, bi-directional transmission process with a master and one or more slaves. The data bits are generated with pulse width modulation of the already existent 22 khz carrier and are superimposed with 600 mv SS of the LNB remote feeding voltage. The digital code words are composed of 8 data bits and one additional parity bit for the recognition of transmission errors. Multiple code words form one DiSEqC TM command. Code words are entered in hex code. Code words Parity bit The MSK 125 can send signals based on DiSEqC TM 1.0 but not receive them. COMMAND OVERVIEW FOR DISEQC TM If a DiSEqC TM matrix is activated with a DiSEqC TM command, the analogue LNB control voltage must first be set to the correct satellite frequency plane, i.e. if a vertical satellite frequency plane is required, the analogue LNB control voltage must be set to 14 V. The correct DiSEqC TM command can then be selected and sent. Launch DiSEqC TM menu The TFT screen provides a selection of the most important DiSEqC TM commands for four satellite positions and their assignment of high band and low band as well as their Horizontal or Vertical polarisation. User entry... Select the desired DiSEqC TM command 32

33 SAT Select DiSEqC Controller 0= User Input 1= V/ LO-Band /Pos. 1 2= H/ LO-Band /Pos. 1 3= V/ HI-Band /Pos. 1 4= H/ HI-Band /Pos. 1 5= V/ LO-Band /Pos. 2 6= H/ LO-Band /Pos. 2 7= V/ HI-Band /Pos. 2 8= H/ HI-Band /Pos. 2 9= more Select DiSEqC Controller 0= User Input 1= V/ LO-Band /Pos. 3 2= H/ LO-Band /Pos. 3 3= V/ HI-Band /Pos. 3 4= H/ HI-Band /Pos. 3 5= V/ LO-Band /Pos. 4 6= H/ LO-Band /Pos. 4 7= V/ HI-Band /Pos. 4 8= H/ HI-Band /Pos. 4 9= more Simple-DiSEqC Commands 0= Tone Burst 1= Data Burst 9= more User entry More - more DiSEqC TM or Simple DiSEqC TM commands Send the selected command string... Input the code words in hex code Input the code words in hex code A... F 33

34 SAT Button Hex Code A B S D E F or Move cursor to the individual code words: Framing, Address, Command and Data Delete the entire command string up to the cursor position Send the selected command string Exit the DiSEqC TM menu Example of a User entry: You wish to check the Kathrein EXR 22 matrix. The command set for the EXR 22 matrix is E (LNB High) and E (LNB Low). Calling up DiSEqC TM : Press SAT CTRL menu Press to call the User entry. The data bits of the individual code words can now be entered using the to and to DiSEqC TM menu buttons. Press the button to send off the control command. The symbol > indicates that the control command has been sent. DiSEqC TM menu Note See the technical appendix for DiSEqC TM command sets for EXR 20, EXR 22 and 9xx series Kathrein matrices. 34

35 SAT COMMAND OVERVIEW FOR THE FRAMING BYTE HEX Byte E0 E1 E2 E3 E4 E5 E6 E7 Description Command from master, one-time transmission Command from master, repeating transmission Command from master, awaiting response, fi rst transmission Command from master, awaiting response, repeated transmission Response from slave, OK, no errors detected Response from slave, command not supported by slave Response from slave, parity error detected Response from slave, command not recognised COMMAND OVERVIEW FOR THE ADDRESS BYTE Hex Byte Description 00 All devices 10 Every LNB, matrix or SMATV 11 LNB 12 LNB with Loop-through 14 Matrix (switcher) 15 Matrix (switcher) with Loop-through 18 SMATV 20 Every polarizer 21 Full skew with linear polarisation 22 Set polarizer step-by-step 30 Every positioner 31 Polar/azimuth positioner 32 Elevation positioner 33 Combined positioner 34 LNB positioner 40 Installation aid 41 Signal strength adjustment help 60 Reserved for allocated addresses 70 Intelligent slave interface for Proprietary Multi-Master bus 71 Interface for nodes and controlled head-ends Fx OEM add-on 35

36 SAT COMMAND OVERVIEW FOR THE COMMAND BYTE Hex Byte Command name The MSK 125 can send commands based on DiSEqC TM 1.0, but cannot receive them. All commands that require DiSEqC TM 2.0 (send and receive) are greyed in the table. Commands shown in bold are preferred for Kathrein switching matrices. Description Number of Data Byte 00 Reset Reset DiSEqC TM microcontroller - 01 Clr Reset Clear reset flag - 02 Standby Power off peripheral power unit - 03 Power on Power on peripheral power unit - 04 Set Contend Set the Contention Flag - 05 Contend Response only if Contention Flag has been set - 06 Clr Contend Clear the Contention Flag - 07 Address Response only if Contention Flag has not been set - 08 Move C Change address if Contention Flag has been set 1 09 Move Change address if Contention Flag has not been set 1 10 Status Read Status Register Flags - 11 Config Read Configuration Flags - 14 Switch 0 Read Switching Status Flags (committed port) - 15 Switch 1 Read Switching Status Flags (uncommitted port) - 16 Switch 2 Expansion option - 17 Switch 3 Expansion option - 20 Set LO Call Low Local Oscillator frequency - 21 Set VR Call up vertical polarisation or clockwise circular polarisation - 22 Set Pos A Select satellite position A - 23 Set S0A Select switch option A - 24 Set Hi Call High Local Oscillator frequency - 25 Set HL Call up horizontal polarisation or anti-clockwise circular - polarisation 26 Set Pos B Select satellite position B - 27 Set S0B Select switch option B - 28 Set S1A Call matrix S1 input A (input B inactive) - 29 Set S2A Call matrix S2 input A (input B inactive) - 2A Set S3A Call matrix S3 input A (input B inactive) - 2B Set S4A Call matrix S4 input A (input B inactive) - 2C Set S1B Call matrix S1 input B (input A inactive) - 2D Set S2B Call matrix S2 input B (input A inactive) - 2E Set S3B Call matrix S3 input B (input A inactive) - 2F Set S4B Call matrix S4 input B (input A inactive) - 30 Sleep All bus commands are ignored except for Awake - 31 Awake Bus commands are accepted again - 38 Write N0 Set port group

37 SAT 39 Write N1 Set port group 1 1 3A Write N2 Expansion option 1 3B Write N3 Expansion option 1 40 Read A0 Read analogue value A0-41 Read A1 Read analogue value A1-48 Write A0 Set analogue value A Write A1 Set analogue value A1 1 4F Write A7 Set analogue value A LO string Read instantaneous frequency - 51 LO now Read instantaneous frequency (table entry number) - 52 LO Lo Read Lo frequency (table entry number) - 53 LO Hi Read Hi frequency (table entry number) - 58 Write Freq Write channel frequency 2 or 3 59 Ch.No. Set selected channel number (receiver) 2 60 Halt Stop positioner - 61 Go E Move positioner eastward - 62 Go W Move positioner westward - 64 P Status Rear positioner status register - 65 Read Pos Read positioner counter - 6C Goto Move positioner motor to Counter Value, Hi, Lo 2 6D Write Pos Set Positioner Counter, Hi, Lo 2 COMMAND OVERVIEW FOR THE DATA BYTE An appropriate data byte must only be sent if the command byte requires data bytes. This can be seen from the above Command Byte table. For more information on which data byte to send to which command byte, please refer to the specification of the device used. Orbit position Polarisation Switch Position H/V Switch position LNB Band Data Byte V Lo F0 V Hi F1 H Lo F2 H Hi F3 V Lo F4 V Hi F5 H Lo F6 H Hi F7 V Lo F8 V Hi F9 H Lo FA H Hi FB V Lo FC V Hi FD H Lo FE H Hi FF 37

38 SAT SCIF/SCR SINGLE CABLE INTERFACE (SAT SINGLE CABLE SYSTEM DISEQC CONTROLLER) This function is available only in SAT mode Launch the LNB menu SCIF/SCR (only DVB-S/S2) Select SCIF Press... to select the type of single cable system s) s) TYPE 1 = TYPE 2 = TYPE 3 = LNB with one local oscillator (10200 MHz) for 4 receivers (UAS481) Single cable switching matrices for 2 local oscillators (9750 / MHz) for 8 receivers (EXR1581, EXR2581, EXR1942, EXR2942, EXU908) Single cable switching matrices for 2 local oscillators (9750 / MHz) for 4 receivers (EXR501, EXR551, EXR552) When you have selected the required single cable type, you will see a menu with the following options: SELECT SCIF/SCR CONTROL 4 = SCIF/SCR EXIT RECEIVER No (receiver number entry) SAT BAND selection. (H/V High Low band selection) RECEIVER off (turns off a receiver signal) SCIF EXIT (turns off the complete single cable system) First, select the receiver number by pressing the button TYPE 1 = LNB with one local oscillator If you have selected TYPE 1, you can now defi ne one of four SELECT SCIF/SCR 4 RECEIVER receiver frequencies. 38 Press to select the 1 st receiver. The transponder frequency which can be defi ned later is set to 1400 MHz. The measuring device automatically adjusts to the selected receiver frequency. After selecting the receiver you automatically go to the menu for SAT BAND selection. The SAT BAND selection menu is displayed depending on the type of single cable system which you selected.

39 SAT SAT BAND selection for TYPE 1 SELECT SCIF/SCR SAT BAND Vertical polarisation Horizontal polarisation With the TYPE 1 SCIF system, there is no distinction between Low and High band because the LO of 10.2 GHz enables both reception bands simultaneously. Transponder Frequency Entry Now enter the transponder frequency. Confi rm your entry. The DiSEqC command for the SCIF system is not sent automatically. The measuring device automatically adjusts to the previously selected receiver frequency. Press the Press button to run a spectrum analysis. to demodulate the signal. You can now log on other receivers to the single-cable system with the measuring device or log them off again: 4 = SCIF/SCR EXIT Press Select Select frequency! Press to return to the SCIF menu! to log on another receiver. to change the polarisation and transponder to log off a receiver. Select to turn off the SCIF system. Note If you wish to work with the measuring device in the conventional way again, without SCIF, you must turn SCIF off again in this menu! If you wish to connect to all four Sat-RF signals at once, enter the command E0 10 5B in the DiSEqC TM user menu. 39

40 SAT Logging off a receiver: Press to log off this receiver. Type 2 = single-cable switching matrices for 2 local oscillators and 8 receivers If you have selected Type 2, you can now define one of eight receiver frequencies. SELECT SCIF/SCR 8 RECEIVER Press to select the 4 th receiver. The transponder frequency which can be defi ned later is set to 1632 MHz. The measuring device automatically adjusts to the selected receiver frequency. After selecting the receiver you automatically go to the menu for SAT BAND selection. The SAT BAND selection menu is displayed depending on the type of single cable system which you selected: SAT BAND selection for TYPE 2 SELECT SCIF/SCR SAT BAND Use the... buttons to select the desired SAT BAND! The required local oscillators are automatically selected! Transponder Frequency Entry Now enter the transponder frequency. 40 Confi rm your entry. The DiSEqC command for the SCIF system is not sent automatically. The measuring device automatically adjusts to the previously selected receiver frequency. Press the button to run a spectrum analysis. Press the button to demodulate the signal. For further operating steps see SCIF/SCR TYPE 1

41 SAT Type 3 = single-cable switching matrices for 2 local oscillators and 4 receivers If you have selected Type 3, you can now defi ne one of four receiver frequencies. SELECT SCIF/SCR 4 RECEIVER Press to select the 1 st receiver. The transponder frequency which can be defi ned later is set to 1400 MHz. The measuring device automatically adjusts to the selected receiver frequency. After selecting the receiver you automatically go to the menu for SAT BAND selection. The SAT BAND selection menu is displayed depending on the type of single cable system which you selected. SAT BAND selection for TYPE 3 SELECT SCIF/SCR SAT BAND Use the... buttons to select the desired SAT BAND! The required local oscillators are automatically selected! Transponder Frequency Entry Now enter the transponder frequency. Confi rm your entry. The DiSEqC command for the SCIF system is not sent automatically. The measuring device automatically adjusts to the previously selected receiver frequency. Press the Press the button to run a spectrum analysis. button to demodulate the signal. For further operating steps see SCIF/SCR TYPE 1 41

42 SAT SIMPLE DISEQC TM, TONE BURST COMMAND OVERVIEW FOR SIMPLE DISEQC TM The Simple Tone Burst DiSEqC TM procedure is a simplified form of the DiSEqC TM controller. Two switching states are possible with this Simple DiSEqC TM, Tone Burst and Data Burst. Launch DiSEqC TM menu Launch Simple DiSEqC TM menu Input Tone Burst, or Input Data Burst Send the command string Exit the DiSEqC TM menu 42

43 SAT LOCATING SATELLITES The function allows you to search for satellites whose transponder frequencies are unknown. The frequency range from 1000 to 2100 MHz is continuously scanned for reception signals. If a reception signal is detected, the reception level is indicated in the display in the form of an increasing or decreasing bar. The buttons allow you to set the measurement range to three sensitivity levels. A bearing tone enables you to monitor the level. The pitch of the bearing tone is proportional to the received signal level. The volume of the bearing tone can be adjusted using the volume buttons. Command overview Switch to the frequency-independent satellite search mode. Select the measurement range, bar graph and bearing tone: Level range 1: Large input levels Level range 2: Medium input levels Level range 3: Small input levels Exit this mode again LCD display: Level range 2: Medium input level SAT mode Bar graph display with bearing sound Example Launching the SAT FIND function: Press. Slowly turn the antenna until a level tendency can be seen on the bar display Slowly turn the antenna until the bar display reaches its maximum If necessary, decrease or increase the sensitivity using the and buttons To quit this task, press 43

44 SAT FINDING INDIVIDUAL RECEPTION FREQUENCIES The function allows you to adjust the antenna to the maximum reception signal. The display indicates the reception in the form of an increasing or decreasing bar. The buttons allow you to set the measurement range to three sensitivity levels. The bearing sound enables you to monitor the level. The pitch of the bearing tone is proportional to the received signal level. The volume of the bearing sound can be adjusted using the Command overview for finding volume buttons. Switch to Find mode. Select the measurement range, bar graph and bearing tone: Level range 1: Large input levels Level range 2: Medium input levels Level range 3: Small input levels Exit this mode again LCD display: Level range 2: Medium input level SAT mode Bar graph display with bearing sound Example Launching the Find level function: Press Slowly turn the antenna until the bar display reaches its maximum If necessary, decrease or increase the sensitivity using the and buttons Slowly turn the antenna until you have reached the maximum level To quit Find Level : Press. 44

45 TV MEASUREMENT ANALOGUE CABLE TV RECEPTION In CABLE mode the MSK 125 can be set to the Analogue and DVB-C types of reception. ANALOGUE CABLE/DVB-C SELECTION Press once Press again Press again = Analogue cable TV = DVB-C = analogue cable TV again RF STANDARD SELECTION - ANALOGUE CABLE (DEMOD MENU) In TV mode the MSK 125 can measure the following standards: B/G standard (Germany) Standard L Standard D/K Standard I B/G standard (Australia) Command overview: Launching the DEMOD menu Call up the menu for standard selection and demodulator setting. 1=B/G 2=L 3=D/K 4=I 5=B/G_AUS... Select standard The Demod menu is then automatically closed. Press the button to select the standard B/G for Australia. Press or to exit the Demod menu without any changes. Note If you wish to keep the settings unchanged, press. Please note that the selected standard is retained even after the device is switched off. 45

46 TV MEASUREMENT CHANNEL DISPLAY AND ENTRY COMMAND OVERVIEW FOR INPUT TV CHANNEL or To measure the level of an reception signal, you must first input the desired frequency. The following channels can be set: Band I/III CH 01 to CH 12 in 7 MHz grid Band IV/V CH 21 to CH 69 in 8 MHz grid Special channel S 01 to S 20 in 7 MHz grid Special channel S 21 to S 41 in 8 MHz grid These details refer to the factory default Standard B/G only. For information on the other standards please see the technical appendix. Select desired TV reception... Input channel Confi rm input or... Enter channel (automatic confi rmation) Select special channel and Change channels step by step Example To enter channel S 28: Press. A LCD display: Special channel: S 28 Level: 62.5 dbμv Operating mode: Analogue cable TV (A=analogue) Note Ensure that the correct standard has been set. The factory default is Standard B/G. FREQUENCY DISPLAY AND ENTRY 46 To measure the level of an reception signal, you must first input the desired video carrier frequency. The frequency can be entered from 47 MHz to 862 MHz in 50 khz steps.

47 TV MEASUREMENT COMMAND OVERVIEW FOR TV FREQUENCY INPUT Select desired TV reception or Channel/frequency selection... Input the frequency Confi rm input and Change frequency in steps Example To enter frequency MHz : Press (launches the frequency menu) Then (frequency entry) LCD display: Frequency: MHz Level: 65.0 dbμv Operating mode: Analogue cable TV Note After launching the frequency menu for the fi rst time you only have to enter the digit sequence for another frequency entry. The most recent frequency setting is retained even after you switch the MSK 125 off, provided it was entered with digits and confi rmed by pressing. CABLE ANALOGUE LEVEL MEASUREMENT Please note that the full-stops before and after the channel number indicate to the precisely selected channel: CH: or CH: S.04. If you enter the channel frequency outside the valid channel grid, the channel is displayed without full-stops: CH: or CH: S 04 When you have selected a channel or frequency, the level is automatically measured and appears on the LCD display as dbμv or dbmv (depending on the device confi guration). The input level can be measured within the range 30 dbμv to 120 dbμv (-30 dbmv to 60 dbmv). LCD display: Channel: 28 CH 05 Operating mode: Analogue cable TV Measured level: 86.5 dbμv 47

48 TV MEASUREMENT LEVEL OVERFLOW AND UNDERFLOW At a level < 30 dbμv the LCD display indicates an underfl ow. CHAN:.05. LCD display: Channel: 28 CH 05 Operating mode: Analogue cable TV Level: underfl ow At a level > 120 dbμv the LCD display indicates an overfl ow. CHAN:.05. Note LCD display: Channel: 28 CH 05 Operating mode: Analogue cable TV Level: overfl ow Levels of DVB-C and DVB-T-/H signals can only be measured in the Digital reception setting. AUDIO CARRIER SPACING AND LEVEL TV stations can transmit on a second FM modulated audio carrier (analogue) or in Nicam format (digital). The audio carriers are assigned different frequencies depending on the selected standard (see table). Audio carrier 1 is always set after the channel or frequency is entered. Standard TT1 TT2 Nicam B/G 5.5 MHz 5.74 MHz 5.85 MHz D/K 6.5 MHz 6.26 MHz 5.85 MHz 6.74 MHz I 6.0 MHz MHz L AM 6.5 MHz MHz With audio carrier measurement the signal spacing between audio and video carrier is measured fi rst in db and then the absolute audio carrier level in dbμv. The speaker is muted during measurement. The modulation of the last audio carrier that was measured is audible when the measurement is complete. COMMAND OVERVIEW FOR MEASURE TV AUDIO CARRIER FREQUENCY Switch to audio carrier menu... Switch between TT1 and TT2 (see table) Audio carrier measurement while button is pressed Switch to Nicam reception 48

49 TV MEASUREMENT Example To measure audio carrier level spacing and level of TT1: Press, now press and keep the button pressed. DIFF: -13.0dB The LCD display shows the following values for approx. 1 second: Audio carrier spacing frequency: 5.5 MHz Audio/video carrier spacing: -13 db Operating mode: Analogue cable TV The audio carrier level is displayed after approx. 1 second: LCD display: Audio carrier spacing frequency: 5.5 MHz Audio carrier level: 58.5 dbμv Operating mode: Analogue cable TV Release the button. To measure audio carrier level spacing and level of TT2: During the audio carrier display press the button. To measure audio carrier level spacing and level of Nicam audio carriers: During the audio carrier display press the button. SELECT SOUND CARRIER Standard B/G 1 = 5.50 MHz FM 2 = 5.74 MHz FM 3 = 5.85 MHz NICAM 0 = 5.50/5.74 MHz Stereo Example To set the headphones output to Stereo, confi rm by pressing the 0 button! The headphones output now delivers stereo sound. 49

50 TV MEASUREMENT Note The audio carrier frequency cannot be adjusted. It is switched based on the set standard. The audio carrier level is only displayed as long as the, buttons or button is pressed. DIGITAL CABLE TV RECEPTION In CABLE mode the MSK 125 can be set to the Analogue and DVB-C types of reception. ANALOGUE CABLE/DVB-C SELECTION Press once Press again Press again = Analogue cable TV = DVB-C = analogue cable TV again CHANNEL DISPLAY AND ENTRY To measure the level of an reception signal, you must first input the desired frequency. The following channels can be set: Band I/III CH 01 to CH 12 in 7 MHz grid Band IV/V CH 21 to CH 69 in 8 MHz grid Special channel S 01 to S 20 in 7 MHz grid Special channel S 21 to S 41 in 8 MHz grid These details refer to the factory default Standard B/G only. For information on the other standards please see the technical appendix. 50

51 TV MEASUREMENT COMMAND OVERVIEW FOR TV CHANNEL ENTRY Select desired TV reception or... Input channel as a single digit Confi rm input or... Input channel as two digits (automatic confirmation) Select special channel and Change channels step by step Example To enter channel S 28: Press. Note LCD display: Special channel: S 28 Level: 62.5 dbμv Operating mode: Digital cable TV (D=digital) Ensure that the correct standard has been set. The factory default is Standard B/G. FREQUENCY DISPLAY AND ENTRY To measure the level of an reception signal, you must first input the desired video carrier frequency. The frequency can be entered from 48 MHz to 858 MHz in 50 khz steps. 51

52 TV MEASUREMENT COMMAND OVERVIEW FOR TV FREQUENCY INPUT Select desired TV reception or Channel/frequency selection... Input the frequency Confi rm input and Change frequency in steps Example To enter frequency MHz: Press Then (launches the frequency menu) (frequency entry) FRQ: MHz Note LCD display: Frequency: MHz Level: 65.0 dbμv Operating mode: TV DVB-C After launching the frequency menu for the fi rst time you only have to enter the digit sequence for another frequency entry. The most recent frequency setting is retained even after you switch the MSK 125 off, provided it was entered with digits and confi rmed by pressing. SETTING DVB-C DEMODULATION PARAMETERS Please note that the full-stops before and after the channel number indicate to the precisely selected channel: CH: or CH: S.04. If you enter the channel frequency outside the valid channel grid, the channel is displayed without full-stops: CH: or CH: S 04 Press to go to demodulation selection: For QAM64 demodulation press. 52

53 TV MEASUREMENT Launching the DEMOD menu If you do not wish to change the modulation type, press 1 = QAM 64 demodulation 2 = QAM 128 demodulation 3 = DOCSIS QAM 64 demodulation 4 = QAM 256 demodulation After selecting the modulation type you are automatically directed to the symbol rate entry. Select the appropriate symbol rate by pressing to. LCD display: 1 = 6900 ks 2 = 6111 ks 3 = 6875 ks 4 = USER QAM Press to go to the menu for USER entry of the symbol rate. Enter the desired symbol rate and complete your entry by pressing. After selecting the symbol rate you are automatically directed to the RF standard selection. 1=B/G 2=L 3=D/K 4=I 5=B/G_AUS... Select standard The Demod menu is then automatically closed. Press the button to select the standard B/G for Australia. Note Press or to exit the Demod menu without any changes. If you wish to keep the settings unchanged, press. Please note that the selected standard is retained even after the device is switched off. 53

54 TV MEASUREMENT LEVEL MEASUREMENT OF DVB-C SIGNALS ANALOGUE CABLE/DVB-C SELECTION Press once Press again = Analogue cable TV = DVB-C CHAN:S.34. LEV:62.5 dbuv Channel: 28 special channel 54 Operating mode: TV DVB-C Measured level: 62.5 dbμv DVB-C MER, BER AND OFFSET MEASUREMENT The modulation error rate (MER), the bit error rate (BER) and the carrier frequency offset can be measured to evaluate the digital reception quality. To launch DVB-C measurement: In CABLE digital or Terrestrial digital reception mode press the button. LCD display for DVB-C signals: MER modulation error rate: 28.5 db Modulation = 256 QAM BER bit error rate: 1.7e-7 Standard = DVB-C Carrier frequency offset: MHz 54

55 TV MEASUREMENT MPEG IMAGE REPRESENTATION IN DVB-C If you select DVB measurement by pressing, the TFT screen displays the list of programmes that can be received on the digital transport stream. Use the or key to select the desired programme and confi rm your selection by pressing. To select the programme, you can also enter the displayed programme number directly..... If the programme can be received free, the picture and sound of the desired programme are decoded and displayed and played back over the built-in speaker. By pressing again you can select another programme from the programme list. Press to exit digital reception. LCD display for DVB-C signals: MER modulation error rate: 28.5 db Modulation = 256 QAM Bit error rate: 1.7e-7 Standard = DVB-C Carrier frequency offset: MHz NIT NETWORK INFORMATION TABLE FOR DVB-C If you select DVB measurement by pressing, the TFT screen displays the list of programmes that can be received on the digital transport stream. Press the decimal point button to receive the NIT. You will receive the operator's information fi rst and the number of pages. You can now use the UP / DOWN buttons to scroll through the pages. Press the decimal point button display. again to close the NIT 55

56 TV MEASUREMENT ANALOGUE TERRESTRIAL TV RECEPTION In TERR mode the MSK 125 can be set to the Analogue and DVB-T/H types of reception. ANALOGUE TERRESTRIAL / DVB T/H SELECTION Press once Press again Press again RF STANDARD SELECTION = Analogue terrestrial TV = DVB-T/H = analogue terrestrial TV again 1=B/G 2=L 3=D/K 4=I 5=B/G_AUS Launch menu for standard selection.... Select standard The DEMOD menu is then automatically closed. Press the button to select the standard B/G for Australia. Press or to exit the DEMOD menu without any changes. RF STANDARD SELECTION 1=B/G 2=L 3=D/K 4=I 5=B/G_AUS Note... Select standard The DEMOD menu then closes automatically. If you wish to keep the settings unchanged, press. Please note that the selected standard is retained even after the device is switched off. Press to exit the menu at any time. RF standard selection is used here to set the channel bandwidth. Press the button to select the standard B/G for Australia. 56

57 TV MEASUREMENT CHANNEL DISPLAY AND ENTRY COMMAND OVERVIEW FOR INPUT TV CHANNEL To measure the level of a TV reception signal, you must first enter the desired channel. The following channels can be set: Band I/III CH 01 to CH 12 in 7 MHz grid Band IV/V CH 21 to CH 69 in 8 MHz grid Special channel S 01 to S 20 in 7 MHz grid Special channel S 21 to S 41 in 8 MHz grid These details refer to the factory default Standard B/G only. For information on the other standards please see the technical appendix.... Input channel as a single digit Confi rm input or... Input channel as two digits (automatic confirmation) and Change channels step by step Example To enter channel 28: Press. CHAN: 28 LEV: 61.0 dbuv Note LCD display: Channel: Level: 61.0 dbμv Operating mode: Analogue terrestrial TV (A = analogue) Ensure that the correct standard has been set. The factory default is Standard B/G. FREQUENCY DISPLAY AND ENTRY To measure the level of a TV reception signal, you must first enter the desired video carrier frequency. The frequency can be entered from 48 MHz to 858 MHz in 50 khz steps. 57

58 TV MEASUREMENT COMMAND OVERVIEW FOR TV FREQUENCY INPUT Channel/frequency selection... Input the frequency Confi rm input and Change frequency in steps Example To enter frequency MHz: Press (launches the frequency menu) Then (frequency entry) FRQ: MHz Note LCD display: Frequency: MHz Level: 65.0 dbμv Operating mode: Analogue terrestrial TV After launching the frequency menu for the fi rst time you only have to enter the digit sequence for another frequency entry. The most recent frequency setting is retained even after you switch the MSK 125 off, provided it was entered with digits and confi rmed by pressing. Please note that the full-stops before and after the channel number indicate to the precisely selected channel: CH: or CH: S.04. If you enter the channel frequency outside the valid channel grid, the channel is displayed without full-stops: CH: or CH: S 04 DIGITAL TERRESTRIAL TV RECEPTION In TERR mode the MSK 125 can be set to the Analogue and DVB-T/H types of reception. ANALOGUE TERRESTRIAL / DVB T/H SELECTION Press once Press again Press again = Analogue terrestrial TV = DVB-T/H = analogue terrestrial TV again 58

59 TV MEASUREMENT SETTING DVB-T/H DEMODULATION PARAMETERS Press DVB-T/H: 1 = 6 MHz demodulation bandwidth 2 = 7 MHz demodulation bandwidth 3 = 8 MHz demodulation bandwidth to go to the bandwidthselection for Note Select the required RF bandwidth by using the digit buttons RF STANDARD SELECTION DVB-T... or exit the entry without any changes by pressing. The MSK 125 sets all other parameters for DVB-T/H demodulation automatically. After selecting the demodulation bandwidth you are automatically directed to the RF standard selection. Note 1=B/G 2=L 3=D/K 4=I 5=B/G_AUS... Select standard The DEMOD menu is then automatically closed. Press the button to select the standard B/G for Australia. If you wish to keep the settings unchanged, press. Please note that the selected standard is retained even after the device is switched off. Press to exit the menu at any time. RF standard selection is used here to set the channel bandwidth. 59

60 TV MEASUREMENT CHANNEL DISPLAY AND ENTRY To measure the level of an reception signal, you must first input the desired frequency. The following channels can be set: Band I/III CH 01 to CH 12 in 7 MHz grid Band IV/V CH 21 to CH 69 in 8 MHz grid Special channel S 01 to S 20 in 7 MHz grid Special channel S 21 to S 41 in 8 MHz grid These details refer to the factory default Standard B/G only. For information on the other standards please see the technical appendix. COMMAND OVERVIEW FOR INPUT TV CHANNEL... Input channel as a single digit... Confi rm input Input channel as two digits (automatic confi rmation) and Change channels step by step Example To enter channel 28: Press. CHAN: 28 LEV: 61.0 dbuv Note LCD display: Channel: Level: 61.0 dbμv Operating mode: Digital terrestrial TV (D = digital) Ensure that the correct standard has been set. The factory default is Standard B/G. FREQUENCY DISPLAY AND ENTRY To measure the level of an reception signal, you must first input the desired video carrier frequency. The frequency can be entered from 48 MHz to 858 MHz in 50 khz steps. 60

61 TV MEASUREMENT COMMAND OVERVIEW FOR TV FREQUENCY INPUT Channel/frequency selection... Input the frequency Confi rm input and Change frequency in steps Example To enter frequency 530 MHz: Press Then (launches the frequency menu) (frequency input) FRQ: 530 MHz LEV: 61.0 dbuv Note LCD display: Frequency: 530 MHz (corresponds to K 28 digital) Level: 61.0 dbμv Operating mode: Digital terrestrial TV After launching the frequency menu for the fi rst time you only have to enter the digit sequence for another frequency entry. The most recent frequency setting is retained even after you switch the MSK 125 off, provided it was entered with digits and confi rmed by pressing. Please note that the full-stops before and after the channel number indicate to the precisely selected channel: CH: or CH: S.04. If you enter the channel frequency outside the valid channel grid, the channel is displayed without full stops: CH: or CH: S 04 61

62 TV MEASUREMENT DVB-T-/H MER, BER AND OFFSET MEASUREMENT The modulation error rate (MER), the bit error rate (BER) and the carrier frequency offset can be measured to evaluate the digital reception quality. To launch DVB-T/H measurement: In CABLE digital or Terrestrial digital reception mode press the button. MER:24.8dB QAM16 2/3 CBER6.4e-8 DT-0.1 MHz LCD display for DVB-T signals: MER modulation error rate: 24.8 db Modulation = 16 QAM FEC 2/3 CBER bit error rate: 6.4e-8 Standard = DVB-T Carrier frequency offset: MHz When you select a programme from the PAT/programme table, the LCD display shows the VBER (Viterbi) bit error rate. 62

63 TV MEASUREMENT LCD display for DVB-C signals: MER modulation error rate: 32.0 db Modulation = 64 QAM BER bit error rate: 6.4e-8 Standard = DVB-C Carrier frequency offset: MHz LCD display for DVB-T signals: MER modulation error rate: 24.8 db Modulation = 16 QAM CBER bit error rate: 6.4e-8 Standard = DVB-T Carrier frequency offset: MHz MPEG IMAGE REPRESENTATION IN DVB-T If you select DVB measurement by pressing, the TFT screen displays the list of programmes that can be received on the digital transport stream. Use the or key to select the desired programme and confi rm your selection by pressing. To select the programme, you can also enter the displayed programme number directly..... If the programme can be received free, the picture and sound of the desired programme are decoded and displayed and played back over the built-in speaker. By pressing again you can select another programme from the programme list. Press to exit digital reception. QAM 16 2/3 During the image display the Viterbi BER is displayed: LC display for DVB-T/H signals: MER modulation error rate: 24.8 db Modulation = 16 QAM VBER Viterbi bit error rate: 6.4e-8 Standard = DVB-T/H Carrier frequency offset: MHz 63

64 TV MEASUREMENT NIT NETWORK INFORMATION TABLE FOR DVB-T If you select DVB measurement by pressing, the TFT screen displays the list of programmes that can be received on the digital transport stream. Press the decimal point button to receive the NIT. You will receive the operator's information fi rst and the number of pages. You can now use the UP / DOWN buttons to scroll through the pages. Press the decimal point button display. again to close the NIT REMOTE POWER FEED FOR DVB-T SELECT LNB Voltage 0=0 Volt 1=12 Volt 2=14 Volt 3=18 Volt 5=5 Volt 8=22 khz A remote power feed can be connected to power an active DVB-T antenna (see Section LNB voltage ). Press the button connects the usual 5V remote power feed. 64

65 TV MEASUREMENT FINDING INDIVIDUAL RECEPTION FREQUENCIES The function allows you to adjust the antenna to the maximum reception signal. The display indicates the reception in the form of an increasing or decreasing bar. The buttons allow you to set the measurement range to three sensitivity levels. The bearing sound enables you to monitor the level. The pitch of the bearing tone is proportional to the received signal level. The volume Command overview for finding of the bearing sound can be adjusted using the volume buttons. Switch to Find mode LCD display: Level range 2: Input level Operating mode: Terrestrial TV bar graph display Select the measurement range, bar graph and bearing tone: Level range 1: Large input levels Level range 2: Medium input levels Level range 3: Small input levels Exit this mode again Example Launching the Find level function: Press Turn the antenna until the bar display reaches its maximum. If necessary, decrease or increase the sensitivity using the and buttons. Turn the antenna until you have reached the maximum level. To quit Find level : Press. 65

66 TV MEASUREMENT NICAM AUDIO BIT ERROR RATE MEASUREMENT Example The bit error rate (BER) can be measured to improvement evaluation of the audio quality of Nicam signals. Launch bit error rate measurement: Press Press If the quality of the Nicam signal is so good that no bit error can be detected, BER=0.000 is displayed. If the Nicam signal is too bad or no signal is received, the display indicates Overflow. This measurement may take a few seconds! TV RETURN PATH MEASUREMENT Analogue and digital reception signals in the frequency range 4 MHz MHz can be measured in the return path. Press to select CABLE analogue to measure analogue signals and CABLE digital to measure digital signals. Press to select TERR analogue to measure analogue signals and TERR digital to measure digital signals. The measuring device automatically switches over to the return path range when a frequency less than MHz is entered. Entering a frequency greater than MHz switches the device back to cable/terrestrial range.... Input the frequency Confi rm input and Change frequency in steps Press to go to the spectrum analysis menu where you can select 5 = Return Path to go to return path spectrum analysis. Press to go to DVB measurement. You can now demodulate DVB-C and DVB-T signals in the return path frequency range (e.g. intermediate frequency MHz). 66

67 FM MEASUREMENT FM SELECTION Press. FREQUENCY DISPLAY AND ENTRY To measure the level of an FM signal, you must fi rst enter the desired frequency. The frequency can be entered from 47 MHz to 859 MHz in 50 khz steps. COMMAND OVERVIEW FOR FM FREQUENCY INPUT Switch to FM reception... Input the frequency Confi rm input and Change frequency in 50 khz steps Example To enter frequency MHz: Press (launching the FM menu) Then (frequency entry) FRQ: Note LCD display: Frequency: MHz Level: 65.0 dbμv Operating mode: FM After launching the FM menu for the fi rst time you only have to enter the digit sequence for another frequency entry. The most recent frequency setting is retained even after you switch the MSK 125 off, provided it was entered with digits and confi rmed by pressing. LEVEL MEASUREMENT FRQ:104.80MHz When you have set a frequency the level is measured automatically and displayed in the LCD display. The input level can be measured in the range from 30 dbμv to 120 dbμv. LCD display: Frequency: MHz Operating mode: FM Measured level: 86.5 dbμv 67

68 FM MEASUREMENT LEVEL OVERFLOW AND UNDERFLOW FRQ:104.80MHz FRQ:104.80MHz At a level < 30 dbμv the display indicates an underfl ow. LCD display: Frequency: MHz Operating mode: FM Level: underfl ow At a level > 120 dbμv the LCD display indicates an overfl ow. LCD display: Frequency: MHz Operating mode: TV Level: overfl ow FINDING INDIVIDUAL RECEPTION FREQUENCIES COMMAND OVERVIEW FOR FIND The function allows you to adjust the antenna to the maximum reception signal. The display indicates the reception in the form of an increasing or decreasing bar. The buttons allow you to set the measurement range to three sensitivity levels. The bearing sound enables you to monitor the level. The pitch of the bearing tone is proportional to the received signal level. The volume of the bearing sound can be adjusted using the volume buttons. Switch to Find mode Select the measurement range, bar graph and bearing tone: Level range 1: Large input levels Level range 2: Medium input levels Level range 3: Small input levels Example Exit this mode again LCD display: Level range 2: Medium input level Operating mode: FM bar graph display To launch the Find level function: Press Turn the antenna until the bar display reaches its maximum. If necessary, decrease or increase the sensitivity with the buttons. Turn the antenna until you have reached the maximum level. To quit Find level : Press 68

69 SPECTRUM MEASUREMENT To evaluate a receiver, the frequency spectrum in the ranges Satellite, Cable, Terrestrial and FM can be displayed on the screen. Spectrum measurement is launched from the respective modes (Sat, Cable, Terr or FM). Command for spectrum measurement:. To exit the measuring task: Press or again. If you exit spectrum analysis using the button, the original reception frequency settings are kept. If you change the cursor position and exit spectrum analysis using, the new cursor frequency is accepted as the new reception frequency. To measure certain level minimums or maximums, you can move Note a cursor on the level curve using the and buttons. The frequency and the measured value are indicated in the top line of the screen. The measuring range is displayed on the ordinate on the left side of the screen. The level measurement range is set automatically. In spectrum analysis it is always the peak value of the level that is measured. 69

70 SPECTRUM MEASUREMENT SAT SPECTRUM SELECT SAT SPECTRUM 1 = FULL SPAN 2 = NARROW FULL SPAN = entire SAT range In SAT mode (see corresponding chapter) the entire Sat spectrum of the selected SAT plane from MHz can be displayed. NARROW ( MHz) TV SPECTRUM The TV spectrum is divided up into four modes (see corresponding chapter), which can be selected using the,, and page: buttons, see screenshot and description on the next 70

71 SPECTRUM MEASUREMENT 5 = Return Path FULL SPAN = entire TV range ( MHz) VHF ( MHz) UHF ( MHz) 71

72 SPECTRUM MEASUREMENT The displayed mean frequency is the previously set reception channel. NARROW (Center MHz) ANALOGUE NARROW (Center MHz) DIGITAL RETURN PATH SPECTRUM The displayed marker frequency shows the previously set reception frequency. RETURN PATH ( MHz) ANALOG/DIGITAL FM SPECTRUM The displayed marker frequency shows the previously set reception frequency. The FM spectrum is selected and measured as described above. Its range is MHz. 72

73 STORING DEVICE SETTINGS STORING DEVICE SETTINGS TFT Display First select the measuring task! Indicates the stored settings on the TFT display and opens the input fi eld to define a storage location on the LCD display. Use the Up and Down buttons to scroll through the screen content. LCD display... Every measurement from 00 to 99 can be stored individually. Done - the setting has been stored. RESTORING DEVICE SETTINGS TFT Display Displays the stored settings on the TFT display and opens the input fi eld of the storage location from where the setting is to be restored. Use the Up and Down buttons to scroll through the screen content. LCD display... Input storage location Every storage location from 00 to 99 can be called up. The setting is applied. DELETING DEVICE SETTINGS TFT Display Displays the stored settings on the TFT display and opens the input fi eld of the storage location where the setting is to be deleted. LCD display - Use the Up and Down buttons to scroll through the screen content.... Enter a point before the storage number: Input the storage location.00 to 99. Any storage location from 00 to 99 can be cleared; or if you enter , the entire storage range will be cleared down. Done - the storage location has been cleared. 73

74 STORING MEASUREMENT RESULTS STORING MEASUREMENT RESULTS IN THE DEVICE MEMORY TFT Display CHAN: S.21. Cable A 04 FRQ: SAT D 05 CHAN:.39. TERR D 06 SPECTRUM SAT-Narrow A LCD display First select the measuring task and perform the measurement! The Memory Explorer command displays the stored measuring results on the TFT display. Use the Up and Down buttons to scroll through the screen content. Opens the entry field on the LCD display where you can determine a storage location for the new measurement result.... Input storage location Every measurement from 00 to 99 can be stored individually. Note Done - the measurement results have been stored in the device. Up to 10 spectrum images can be stored. You can select any storage location (storage number) of your choice. If you try to store more than 10 spectrum images, the following message will be displayed: Spectrum Memory Full! Only 10 Spec. Possible You must now clear at least 1 spectrum storage location (see next page). RESTORING MEASUREMENT RESULTS FROM THE DEVICE MEMORY TFT Display CHAN: S.21. Cable A 04 FRQ: SAT D 05 CHAN:.39. TERR D 06 SPECTRUM SAT-Narrow A LCD display The Memory Explorer command displays the stored measuring results on the TFT display. Use the Up and Down buttons to scroll through the screen content. Opens the entry fi eld on the LC display for entry of the storage location from which the measurement results are to be retrieved.... Input storage location Every storage location from 00 to 99 can be called up. The measurement results are shown on the TFT display. 74

75 STORING MEASUREMENT RESULTS DELETING MEASUREMENT RESULTS FROM THE DEVICE MEMORY TFT Display The Memory Explorer command displays the stored measuring results on the TFT display. Indicates the stored settings on the TFT display and opens the entry fi eld of the storage location where the measurement results are to be cleared. LCD display Use the Up and Down buttons to scroll through the screen content.... Enter a point before the storage number: Enter storage location.00 to 99. Any storage location from 00 to 99 can be cleared; or if you enter , the entire storage range will be cleared down. Done - the memory location has been cleared. STORING MEASUREMENT RESULTS ON THE SD CARD First retrieve the measurement result stored in the device on to the TFT display as described above under Recovering measurement results. In this case, storage location 2 : TFT Display CHAN:S.32. Storage location 02 is displayed. Now press. LCD display The LCD display shows from 02 - If you now press again without entering a further storage location, the measurement results from memory 02 will be stored on the SD card (memory card) under a sequential number. 75

76 STORING MEASUREMENT RESULTS LCD display If you wish to copy a complete storage range to the SD card, enter the last storage location before you press e.g.: from for the second time, LCD display! Please wait!! writing to SD card! Note Storage locations 02 to 15 are stored on the SD card under a sequential number. The LCD display confi rms the storage with the message Please wait, writing to SD Card. The measurement device saves the data as an.xht fi le. You can either transfer the measurement results on the SD card to a PC via USB connection or read, manage and print out the SD card directly on your PC. The required conversion program is available on our web site. Please go to then select Service Software/Download Measurement devices for MSK 125. Displaying individual measured values: Storage location 02 is displayed 76

77 DATA LOGGER The Data Logger setting allows you to execute the stored measurement device settings in sequence and store the corresponding measurement results. The stored device settings are used for automatic measuring. Up to 100 ( ) different measurement series can be stored. Note Before using the DATA LOGGER function you must store the required device settings in the Store device settings menu. TFT Display Data logging memory Press (Data Logger) to launch the Automeasure function. Use the Up and Down buttons to scroll through the screen content. LCD display The LCD display displays the message Press MEMO EXPL for measurement results. During a measurement process you can use a maximum of 10 spectrum settings. If you try to run more than 10 spectrum settings, the following message will be displayed: Spectrum Memory Full! Only 10 Spec. Possible! At this point the Data Logger stops its measurement. ENTERING THE START AND STOP LINE FOR AUTOMATIC MEASURING ENTERING THE START LINE FOR AUTOMATIC MEASURING... Use the button and the two-digit setting storage number to select the start line where automatic measuring is to start. 77

78 DATA LOGGER ENTERING THE STOP LINE FOR AUTOMATIC MEASURING... Use the two-digit setting storage number to select the stop line where automatic measuring is to stop. STARTING AND INTERRUPTING AUTOMATIC MEASURING Use the cursor button to start automatic measuring. Automatic measuring stops at the stop line. The measurement results are stored in the measured value memory. Use the cursor button measuring manually. to interrupt automatic RESTORING MEASUREMENT RESULTS FROM THE DEVICE MEMORY TFT Display The Memory Explorer command shows the stored measuring results on the TFT display. Use the Up and Down buttons to scroll through the screen content. LCD display TFT Display CHAN:S.32. Opens the entry field on the LCD display for entering the storage location where the measurement results are to be retrieved.... Input storage location The measurement results are shown on the TFT display (example: measurement result no.: 02). 78

79 DATA LOGGER STORING THE DATA LOGGER MEASUREMENT RESULTS ON THE SD CARD See: Storing measurement results on the SD card Example Data logging memory Call up Data Logger Select start line Select stop line Start Automeasure This may take a little while (depending on the amount of measurement). When the run is complete: Launch measured value memory Get fi rst measurement result from the memory Store measurement results on the SD card! Please wait!! writing to SD card! from 01- Select stop line After it has saved the measured values the measurement device displays: Message: The measurement results have been written to a fi le (automatic file number) on the SD card. CHAN: 000 ME xxxxxx.xht WRIT. 79

MSK 125 For software version V1.2

MSK 125 For software version V1.2 Operating Manual Antenna Measuring System MSK 125 For software version V1.2 FOREWORD/IMPORTANT INSTRUCTIONS Dear customer, thank you for choosing the Kathrein MSK 125 measuring instrument. Please read

More information

MSK 120 From software version V1.3

MSK 120 From software version V1.3 Operating manual DIGITAL-SAT-METER MSK 120 From software version V1.3 FOREWORD/IMPORTANT INSTRUCTIONS Dear customer, thank you for choosing the Kathrein MSK 120 satellite meter. Please read the following

More information

Owner s Manual. Sat-Meter MSK 15. Order No.:

Owner s Manual. Sat-Meter MSK 15. Order No.: Owner s Manual Sat-Meter MSK 15 Order No.: 217 100 13 Thank you for choosing our latest and most innovative satellite meter. It has been designed and manufactured to a very high standard and offers a UNIQUE

More information

S7000L. TV & Satellite Analyzer. All IN ONE. Satellite & Terrestrial. Key Features. Model Guide

S7000L. TV & Satellite Analyzer. All IN ONE. Satellite & Terrestrial. Key Features. Model Guide S7000 TV & Satellite Analyzer Key Features All standards in one: QAM(J.83A/B/C), 8VSB, DVB-T/H/T2, DVB-S/ S2 Digital/Analog TV and Satellite TV analysis MPEG2 Transport stream analyzer and monitoring via

More information

Operating Manual. DVB-T Meter MFK 16

Operating Manual. DVB-T Meter MFK 16 Operating Manual DVB-T Meter MFK 16 Preface Dear customer, KATHREIN-Werke KG has made every effort to ensure the accuracy and completeness of this manual. However, no liability can be accepted for potential

More information

Horizon HD-STM. Combo Signal Analyzer TEST REPORT

Horizon HD-STM. Combo Signal Analyzer TEST REPORT TEST REPORT Combo Signal Analyzer Horizon HD-STM can be used intuitively, manual is not needed perfect workmanship optimized for the day-to-day work of an installer gives all the "Must-Have" informations

More information

SATELLITE FINDER SK-3200 USER MANUAL

SATELLITE FINDER SK-3200 USER MANUAL SATELLITE FINDER SK-3200 USER MANUAL CONTENTS 1. GUIDE...1 1.1 IMPORTANT SAFETY INSTRUCTIONS... 1 1.2 UNPACKING...1 1.3 PRODUCT OVERVIEW & ILLUSTRATION... 2 2. OUTLINE...4 3. THE MENU OSD INSTRUCTION...5

More information

Digital Terrestrial Alignment & Installation Meter

Digital Terrestrial Alignment & Installation Meter Digital Terrestrial Alignment & Installation Meter Instruction Booklet Version 3 - February 2005 www.horizonhge.com Thank you for choosing our latest and most innovative terrestrial meter. It has been

More information

Operating Manual - Englisch - DVB combi receiver (SAT + DVB-T) UFS 790si/sw

Operating Manual - Englisch - DVB combi receiver (SAT + DVB-T) UFS 790si/sw Operating Manual - Englisch - DVB combi receiver (SAT + DVB-T) UFS 790si/sw FOREWORD/SERVICE Dear customer, this operating manual is intended to help you make the fullest use of the extensive range of

More information

Software version 8.2. Operating manual

Software version 8.2. Operating manual Software version 8.2 Operating manual 2 Preface Preface Dear customer, This following manual will help you obtain the best optimal use from the extensive functions of the MSK 33. Therefore, observe all

More information

HD-CM HORIZON DIGITAL CABLE METER

HD-CM HORIZON DIGITAL CABLE METER HD-CM OFF! Max RF i/p = +17dBm 75Ω Max AC/DC i/p = 120Vrms MENU INPUT ON HORIZON DIGITAL CABLE METER Horizon Global Electronics Ltd. Unit 3, West Side Flex Meadow Harlow, Essex CM19 5SR Phone: +44(0) 1279

More information

LEVEL METER FOR ANALOGUE AND DIGITAL SIGNALS

LEVEL METER FOR ANALOGUE AND DIGITAL SIGNALS Multimedia Electronics LEVEL METER FOR ANALOGUE AND DIGITAL SIGNALS 5 VERSIONS FOR EVERY REQUIREMENT Antenna Measuring Technology By Professionals for Professionals The UPM Range for CATV, and Terrestrial

More information

Operating Manual - Englisch - DVB combi receiver (SAT + DVB-T) UFS 790si/sw

Operating Manual - Englisch - DVB combi receiver (SAT + DVB-T) UFS 790si/sw Operating Manual - Englisch - DVB combi receiver (SAT + DVB-T) UFS 790si/sw FOREWORD/IMPORTANT INFORMATION Dear customer, This operating manual is intended to help you make the fullest use of the extensive

More information

PCM-1210 DVB COMBO METER User`s Manual

PCM-1210 DVB COMBO METER User`s Manual PCM-1210 DVB COMBO METER User`s Manual 1. Main Features... 1 2. Buttons and Indicators... 2 3. How to measure... 3 4. Home menu... 4 5. Satellite... 4 5.1 Satellite Measure... 4 5.2 LNB Setting... 5 5.3

More information

Satellite locator WS-6933

Satellite locator WS-6933 R Satellite locator WS-6933 User's Manual English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW&ILLUSTRATION...3 2. OUTLINE...4 3. THE MENU OSD INSTRUCTION...5

More information

STM 17 HD. DVB-S2+T2/C Compact Meter. User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE.

STM 17 HD. DVB-S2+T2/C Compact Meter. User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE. STM 17 HD DVB-S2+T2/C Compact Meter User Manual Ref 0145131R13 DVB COMBO METER 1. Main Features... 2 2. Buttons and Indicators... 3 3. How to measure... 4 4. Home menu... 5 5. Satellite... 5 5.1 Satellite

More information

HDTV Digital ASI PHDA 8007 ASI. English. Phone: +49 (0) 911 / Fax: +49 (0) 911 / Internet:

HDTV Digital ASI PHDA 8007 ASI. English. Phone: +49 (0) 911 / Fax: +49 (0) 911 / Internet: HDTV Digital ASI PHDA 8007 ASI KLASSE CLASS English GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D-90471 Nuremberg Phone: +49 (0) 911 / 703 8877 Fax: +49 (0) 911 / 703 9210 E-mail: info@gss.de Internet:

More information

Operating manual. DVB Satellite Receiver UFS 640si

Operating manual. DVB Satellite Receiver UFS 640si Operating manual DVB Satellite Receiver UFS 640si PREFACE Dear customer, This operating manual is intended to help you make the fullest use of the extensive range of functions offered by your new satellite

More information

HD RANGER+ Evolution? NO. Revolution!

HD RANGER+ Evolution? NO. Revolution! Evolution? NO. Revolution! The SIXTH GENERATION field meter FROM PROMAX lite ACTUAL SIZE - 7 SCREEN (APPROX. 155 x 93 mm) Revolutionising the market. Again The largest and brightest display HD RANGER+

More information

The new standard for customer entertainment

The new standard for customer entertainment The new standard for customer entertainment TDH 800 basic headend system your ultimate connection 2 TRIAX TDH 800 New standard for basic headend systems The TDH 800 is a basic headend system designed to

More information

SATFINDER 3 HD SLIM USER GUIDE

SATFINDER 3 HD SLIM USER GUIDE SATFINDER 3 HD SLIM USER GUIDE INDEX General Safety..... 3 Key Features..... 4 Panel Keypads... 5 Accesory.. 6 Satellite Search...... 7 Spectrum..... 8 Cross Polarisation... 9 Packet TP Levels.... 9 Multi

More information

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier Kramer Electronics, Ltd. USER MANUAL Model: 900xl Power Amplifier Introduction Contents 1 Introduction 1 2 Getting Started 1 2.1 Recycling Kramer Products 1 3 Overview 2 4 Your 900xl Power Amplifier 3

More information

ATLANTA ASF 2033HD+ DVB-S/S2 METER. User`s Manual

ATLANTA ASF 2033HD+ DVB-S/S2 METER. User`s Manual ATLANTA ASF 2033HD+ DVB-S/S2 METER User`s Manual Buttons and Indicators... 2 How to measure... 3 Main menu... 4 LNB Setting... 4 Edit Satellite... 6 Spectrum Chart... 7 Constellation... 9 Angle Calculation...

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

INSTRUCTION MANUAL SATELLITE. Version V4.0. NTi R. NTi. 13V[] 17V[] 22Kc[]> TBrst[] DiSEqC[] ü. Edition 11/2004 DILAN 2150 SAT LEVEL METER

INSTRUCTION MANUAL SATELLITE. Version V4.0. NTi R. NTi. 13V[] 17V[] 22Kc[]> TBrst[] DiSEqC[] ü. Edition 11/2004 DILAN 2150 SAT LEVEL METER C/N FEC dbuv VITERBI REED-SOLOMON DVB MPEG-2 QPSK BER FEC QPSK C/N FEC dbuv VITERBIREED-SOLOMON DVB MPEG- 2 QPSK BER C/N FEC dbuv VITERBI REED- SOLOMON DVB MPEG QPSK C/N FEC dbuv VITERBI REED-SOLOMON DVB

More information

Television Analyser - TVA97

Television Analyser - TVA97 Television Analyser - TVA97 Multi-functional instrument for RF applications setting the pace in professional RF technology summary setting the pace in professional RF technology Feature Frequency, Gain

More information

DIGITAL SATELLITE METER

DIGITAL SATELLITE METER DIGITAL SATELLITE METER THE PROFESSIONAL EQUIPMENT DIGITAL SATELLITE METER THE PROFESSIONAL EQUIPMENT USER S MANUAL Product Description 1.Guide 2. Menu 1.1 Face Panel & Button 1.2 Power On/Off 1.3Power

More information

UNFOLD THE BASE. Quick Start Guide CONTENTS INSTALLING LCD TV ON THE WALL

UNFOLD THE BASE. Quick Start Guide CONTENTS INSTALLING LCD TV ON THE WALL Quick Start Guide English CONTENTS INSTALLING LCD TV ON THE WALL.. UNFOLD THE BASE............... TV CHANNEL INSTALLATION........ PRESENTATION OF THE LCD TV..... ACCESSORIES.................... BATTERY

More information

ST-4000 SIGNAL LEVEL METER

ST-4000 SIGNAL LEVEL METER ST-4000 SIGNAL LEVEL METER Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter.... 3 Quick Use Instructions.. 3 Main

More information

MyM-3S Micro Master. Installation Guide. English. design for TV

MyM-3S Micro Master. Installation Guide. English. design for TV MyM-3S Micro Master Installation Guide design for TV 1 CONTENT 1. Introduction 2. Unpacking the unit 3. Connections and indications 4. IP settings 5. Menus and settings 5.1 Overview menu 5.2 Input settings

More information

Instructions for use. UFS 810 English IMPORTANT READ CAREFULLY BEFORE USE

Instructions for use. UFS 810 English IMPORTANT READ CAREFULLY BEFORE USE Instructions for use UFS 810 English IMPORTANT READ CAREFULLY BEFORE USE List of Contents 1 About these instructions...4 1.1 Contents...4 1.2 Markings...4 1.2.1 Pre-requirements for certain functions...4

More information

Kathrein Satellite Receiver UFD 400

Kathrein Satellite Receiver UFD 400 Operating manual Kathrein Satellite Receiver UFD 400 Order No.: 260 467 Contents Inhalt Controls, displays and connections... 3 View of front panel, rear panel and remote control handset... 3 Description

More information

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION...17

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION...17 USER S MANUAL English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW& ILLUSTRATION...3 1.4 INSTALLATION OF METER...4 2. OUTLINE...5 3. THE MENU OSD INSTRUCTION...6

More information

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

Ultra-ViewRF 8HD Director Monitor. User Operation Manual Ultra-ViewRF 8HD 5.8GHz Wireless Director Monitor User Operation Manual 17.1.2013 v2_7 Video Equipment Rentals - VER 912 Ruberta Avenue Glendale, CA 91201 - U.S.A. Office 818-956-1444 Table of Contents

More information

RFT-851FTA. Twin DVB-T to PAL remodulator. User Manual

RFT-851FTA. Twin DVB-T to PAL remodulator. User Manual RFT-851FTA Twin DVB-T to PAL remodulator User Manual 1. Purpose of use RFT-851FTA is designed for prosessing two COFDM modulated signals into standard CCIR channels. RFT-851FTA is supplied with a A2 stereo/dual/swap

More information

UFS 910. Operating manual - englisch - HDTV receiver for satellite reception

UFS 910. Operating manual - englisch - HDTV receiver for satellite reception UFS 910 Operating manual - englisch - HDTV receiver for satellite reception PREFACE Dear customer, this Operating Manual is intended to help you make the fullest use of the extensive range of functions

More information

Xsarius Satmeter Pro. Manual

Xsarius Satmeter Pro. Manual Xsarius Satmeter Pro Manual 1 2 Directory of content Introduction Directory of content 3 Introduction 3 Satmeter Pro 02 Frontpanel & buttons 6 Xsarius provides high quality products that enable you to

More information

Kathrein Satellite Receiver UFD 420

Kathrein Satellite Receiver UFD 420 Operating Manual Kathrein Satellite Receiver UFD 420 Order No.: 260 441 Contents Controls, displays and connections... 3 View of front panel, rear panel and remote control handset... 3 Description of controls,

More information

ST-4000D SIGNAL LEVEL METER

ST-4000D SIGNAL LEVEL METER ST-4000D SIGNAL LEVEL METER Rev 100606 Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter...... 3 Quick Use Instructions.....

More information

Manual. Antenna measuring system MSK 200. Valid from software version V 3.8

Manual. Antenna measuring system MSK 200. Valid from software version V 3.8 Antenna measuring system MSK 200 Manual Valid from software version V 3.8 FOREWORD/IMPORTANT INSTRUCTIONS Dear customer, please follow all the information given in this manual. KATHREIN-Werke KG has made

More information

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica AVE HOME CVBS TO DVB-T ENCODER MODULATOR FAGOR Fagor Electr6nica TABLE OF CONTENTS 1. SPECIFICATIONS... 12 1.1 Product Overview... 12 1.2 Appearance and Description... 12 1.3 Diagram... 13 1.4 Characteristics...

More information

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR INSTRUCTION MANUAL Features of the new DVB-C transmodulators line Through the use of the FPGA technology the transmodulators provides the highest performance at the lowest price. Four carriers are formed

More information

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING...

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING... English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW& ILLUSTRATION...3 1.4 INSTALLATION OF METER...4 2. OUTLINE...5 3. THE MENU OSD INSTRUCTION...6

More information

The new standard for customer entertainment

The new standard for customer entertainment The new standard for customer entertainment TDH 800 headend system your ultimate connection 2 TRIAX TDH 800 New standard for headend systems The TDH 800 is a headend system designed to provide cost effective

More information

SAT IF distribution system

SAT IF distribution system 7. Technical specifications Type cs43 RF input frequency range pr. 50-350 MHz inputs number 4 level pr. 55...88 dbµv 60...93 dbµv symbol rate 3 45 Ms/s return loss/impedance > 0 db/75 Ω LNB powering/control

More information

MANUAL ENG DT-1600 ENGLISH. Also contains Menu options and data for built-in modulator Data for broadband amplifier QPSK

MANUAL ENG DT-1600 ENGLISH. Also contains Menu options and data for built-in modulator Data for broadband amplifier QPSK ENG-1 030206 01261-3 ENGLISH Also contains Menu options and data for built-in modulator Data for broadband amplifier QPSK A versatile digital receiver with a guaranteed future has been developed to transmit

More information

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING...

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING... USER S MANUAL English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW& ILLUSTRATION...3 1.4 INSTALLATION OF METER...4 2. OUTLINE...5 3. THE MENU OSD INSTRUCTION...6

More information

TV4U DVB-S2 to DVB-S2 TRANSMODULATOR

TV4U DVB-S2 to DVB-S2 TRANSMODULATOR TV4U to TRANSMODULATOR TV4U to TRANSMODULATOR INSTRUTION MANUAL TV4U to TRANSMODULATOR The main application of to transmodulator Experience of MVDS terrestrial broadcasting shows that carrier must be restored

More information

1. GUIDE Important Safety Instructions Unpacking PRODUCT OVERVIEW&ILLUSTRATION INSTALLATION OFMETER

1. GUIDE Important Safety Instructions Unpacking PRODUCT OVERVIEW&ILLUSTRATION INSTALLATION OFMETER 1. GUIDE... 3 1.1 Important Safety Instructions... 3 1.2 Unpacking... 3 1.3 PRODUCT OVERVIEW&ILLUSTRATION... 4 1.4 INSTALLATION OFMETER... 6 2. OUTLINE... 6 3. THE MENU OSD INSTRUCTION... 7 3.1 DVB S2...

More information

Single cable multiswich programmer PC102W

Single cable multiswich programmer PC102W Single cable multiswich programmer PC102W 1. Product description The PC102W - single cable multiswich programmer (in the text - programmer) is useful instrument while configuring and troubleshooting SAT

More information

STC 160 Head-End Station Quad modulators

STC 160 Head-End Station Quad modulators STC 160 Head-End Station Quad modulators HMS 480 HMM 480 / HMM 480 OIRT Notes on the Assembly Instructions. As well as this supplementary Assembly Instructions, the Assembly Instructions for the STC 160

More information

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual GENERAL FEATURES Easy-to-understand user-friendly menu and keypad. LNB short circuit protection. Display of Analog Signal Level, Digital Signal Quality with % and Bar, audible notification. Timer Lock,

More information

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2 INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2 Dear music lover, thank you for purchasing a Pro-Ject Audio Systems FM-tuner. In order to achieve maximum performance and reliability you should study these instructions

More information

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L HD4112 Manual Rev 1 Contents 1. GENERAL 1.1 Description 1.2 Specifications 2. INSTALLATION 2.1 What s in the Box 2.2 Connection 2.2.1

More information

FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL

FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL Please read this instruction manual carefully before using your receiver Table of Contents Introduction-----------------------------------------------------------------------------

More information

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S INSTRUCTIONS FOR USE Pro-Ject Tuner Box S Dear music lover, thank you for purchasing a Pro-Ject Audio Systems FM-tuner. In order to achieve maximum performance and reliability you should study these instructions

More information

DIGITAL SET TOP BOX STB 7017 INSTRUCTION MANUAL

DIGITAL SET TOP BOX STB 7017 INSTRUCTION MANUAL DIGITAL SET TOP BOX STB7017 INSTRUCTION MANUAL STB 7017 CHANNEL After Sales Support Now you have purchased a Tevion product you can rest assured in the knowledge that as well as your 3 year parts and labour

More information

SM-10 SAT Level Meter User s Manual

SM-10 SAT Level Meter User s Manual SM-10 SAT Level Meter User s Manual DAGATRONICS CORPORATION 263-1 DUCKIDONG, ILSAN, KOYANG, KYUNGKIDO, KOREA TEL: +82-31-916-8005 FAX: +82-31-916-8080 Email: dagatron@dagatron.com Website: www.dagatron.com

More information

MTD 120. (Color) Ref BER. (Bit Error Rate) TV & SAT Level Meter. User s manual

MTD 120. (Color) Ref BER. (Bit Error Rate) TV & SAT Level Meter. User s manual MTD 120 Ref. 4202 Ref. 4207 (Color) (B/N)-- BER (Bit Error Rate) TV & SAT Level Meter User s manual INDEX... Page 1.- GENERAL... 105 1.1.- Description... 105 1.2.- Specifications... 106 2.- SAFETY RULES...

More information

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/ 11/6/2009 www.elber.com elber@elber.it TCU/RCU RF Head Control Units User Manual Elber s.r.l.- Via Pontevecchio, 42W Phone +39-0185.35.13.33 16042 Carasco (GE) Italy Fax +39-0185.35.13.00 1 Sommario 2

More information

Front and Rear Panel Remote Control Connecting to a Television...4. Connecting to an Audio System...5

Front and Rear Panel Remote Control Connecting to a Television...4. Connecting to an Audio System...5 Table of Contents Front and Rear Panel... 1 Remote Control...... 2 Connecting to a Television...4 Connecting to an Audio System...5 Connecting to a DVD Recorder or VCR... 6 First Time Installation... 7

More information

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING...

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING... USER S MANUAL English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW& ILLUSTRATION...3 1.4 INSTALLATION OF METER...4 2. OUTLINE...5 3. THE MENU OSD INSTRUCTION...6

More information

All the functions you need in your hand

All the functions you need in your hand All the functions you need in your hand Rely on H30FLEX for installation and troubleshooting. Robust, light-weight and extremely easy to use. Carry out installation, maintenance and troubleshooting tasks

More information

English CONTENTS 1. GUIDE FEATURES THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION... 7

English CONTENTS 1. GUIDE FEATURES THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION... 7 USER S MANUAL English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 GENERAL DESCRIPTION...2 1.3 PRODUCT OVERVIEW & ILLUSTRATION...3 2. FEATURES...4 3. THE MENU OSD INSTRUCTION...5 4.

More information

English SAFETY PRECAUTION DO NOT INSTALL THE RECEIVER: PAG. 2

English SAFETY PRECAUTION DO NOT INSTALL THE RECEIVER: PAG. 2 U4127 SAFETY PRECAUTION The lightning fl ash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to dangerous voltage and to prevent from a risk of electric shock. Warning:

More information

16 channels transmodulator S2C16

16 channels transmodulator S2C16 16 channels transmodulator S2C16 Vers. 1.01 USER S MANUAL S2C16 - SAT to QAM transmodulator 1. Product description S2C16 is a 16 channel transmodulator with DVB-S/S2 input and DVB-C output. It has 4 main

More information

Goodmans Helpline Phone Number

Goodmans Helpline Phone Number Goodmans Helpline Phone Number 0870 873 0080 contents Introduction 4 Connecting up 5 Overview diagrams 6 Getting started 8 Using the main menu 10 Troubleshooting 15 Technical Specifications 16 3 introduction

More information

SZU OPERATING INSTRUCTIONS SAT NAVI

SZU OPERATING INSTRUCTIONS SAT NAVI SZU 21-00 O P ER ATI N G I N S T R U C T I O N S SAT NAVI Operation Instructions SZU 21-00 Safety Notes Turn off the receiver or any used power supply before installing, to avoid short-circuit. Installation

More information

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview Dual Satellite Tracking Meter 38.8 With a built in Khz tone generator Specifications Power demand over 800 ma will result in an Over Current indication. Compatible With STARBAND Receivers Input Frequency:

More information

OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON

OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON CH+ CH- TABLE OF CONTENTS SAFETY PRECAUTIONS IMPORTANT SAFETY INSTRUCTIONS and FEATURES ACCESSORIES and LOADING BATTERIES REMOTE CONTROL UNIT FRONT PANEL and REAR

More information

X-DVB-S / FM twin. Operating instructions

X-DVB-S / FM twin. Operating instructions X-DVB-S / FM twin Operating instructions Picture Content 1 Description................................Page 2 2 Programming with the HE software............ Page 3 2.1 Basics................................

More information

Super Installer Lite USER MANUAL

Super Installer Lite USER MANUAL Super Installer Lite USER MANUAL Contents Super Installer Lite - Description..... page 3 Getting Started........ page 4 Power On/Off Power Supply and Battery How to use the meter Menu.......... page 7

More information

DIVERSITY DVB-T RECEIVER (DDR)

DIVERSITY DVB-T RECEIVER (DDR) User s Manual The most important thing we build is trust. DIVERSITY DVB-T RECEIVER (DDR) Cobham Surveillance GMS Products 1916 Palomar Oaks Way Ste 100 Carlsbad, CA 92008 100-M0062X2 T: 760-496-0055 05/15/09

More information

GDB9 INSTRUCTION MANUAL DIGITAL TERRESTRIAL RECEIVER

GDB9 INSTRUCTION MANUAL DIGITAL TERRESTRIAL RECEIVER GDB9 INSTRUCTION MANUAL DIGITAL TERRESTRIAL RECEIVER Goodmans Support: www.goodmans.co.uk/support Please read these instructions before use and keep for future reference IMPORTANT SAFETY INSTRUCTIONS Thank

More information

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas Broadcasting Product Brochure 03.00 R&S EFL240/ R&S EFL340 Portable TV Test Receiver

More information

PROMAX NEWSLETTER Nº 22

PROMAX NEWSLETTER Nº 22 PROMAX NEWSLETTER Nº 22 TV EXPLORER HD series: H.264 / MPEG-4 AVC picture CV-100: Optical LNB adapter for TV EXPLORER MO-370: ISDB-T/T B modulator DIGITAL To TV: for Broadcast and TV Distribution PROMAX-27:

More information

CHAPTER 4 STARTUP

CHAPTER 4 STARTUP Contents 1 Contents CONTENTS ----------------------------------------------------------------------------------------------------------- 1 CHAPTER 1 NOTES ON SAFETY AND USE, MAINTENANCE AND SERVICE--------------------

More information

INSTRUCTION MANUAL. 19 HD Widescreen Water Resistant Television VSPA19LCD-AE1B VSPA19LCD-AE1M VSPA19LCD-AE1W. Model No. FINGER TOUCH TECHNOLOGY RATED

INSTRUCTION MANUAL. 19 HD Widescreen Water Resistant Television VSPA19LCD-AE1B VSPA19LCD-AE1M VSPA19LCD-AE1W. Model No. FINGER TOUCH TECHNOLOGY RATED INSTRUCTION MANUAL 19 HD Widescreen Water Resistant Television VSPA19LCD-AE1B Model No. VSPA19LCD-AE1M VSPA19LCD-AE1W FINGER TOUCH TECHNOLOGY IMPORTANT: Please read these instructions before installing

More information

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. DSA-1 The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. The DSA-1 is an invaluable trouble-shooting tool for digital audio equipment and installations. It is unique as a handportable,

More information

AN2056 APPLICATION NOTE

AN2056 APPLICATION NOTE APPLICATION NOTE Extension of the SRC DiSEcQ 1 standard for control of Satellite Channel Router based one-cable LNBs 1 System overview 1.1 Description ST Microelectronics has introduced a new device that

More information

Portable TV Meter (LCD) USER S MANUAL

Portable TV Meter (LCD) USER S MANUAL 1 Portable TV Meter User Manual (LCD) Portable TV Meter (LCD) USER S MANUAL www.kvarta.net 1 / 19 2 Portable TV Meter User Manual (LCD) Contents 1. INTRODUCTION... 3 1.1. About KVARTA... 3 1.2. About DVB...

More information

English SAFETY PRECAUTION DO NOT INSTALL THE RECEIVER: PAG. 2

English SAFETY PRECAUTION DO NOT INSTALL THE RECEIVER: PAG. 2 U4125 SAFETY PRECAUTION The lightning fl ash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to dangerous voltage and to prevent from a risk of electric shock. Warning:

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in

More information

SM02. High Definition Video Encoder and Pattern Generator. User Manual

SM02. High Definition Video Encoder and Pattern Generator. User Manual SM02 High Definition Video Encoder and Pattern Generator User Manual Revision 0.2 20 th May 2016 1 Contents Contents... 2 Tables... 2 Figures... 3 1. Introduction... 4 2. acvi Overview... 6 3. Connecting

More information

Horizon Global Electronics Ltd.

Horizon Global Electronics Ltd. Horizon Global Electronics Ltd. First Floor Office Allen House Edinburgh Way Harlow Essex CM20 2HJ Phone: +44(0) 1279 417005 Fax: +44(0) 1279 417025 Issue No.??123/0.1 Horizon Part Number:??123 Copyright

More information

STM 26 HD. DVB-S2+T2/C Compact meter User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE

STM 26 HD. DVB-S2+T2/C Compact meter User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE STM 26 HD DVB-S2+T2/C Compact meter User Manual Ref 0145225R13 Preface USER MANUAL Please read this manual carefully before using your Digital Sat meter for the first time. This operating manual will help

More information

SNG-2150C User s Guide

SNG-2150C User s Guide SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120

More information

DIGISAT MULTI USER MANUAL

DIGISAT MULTI USER MANUAL DIGISAT MULTI USER MANUAL CONTENTS: Meter specifications page 3 Accessories included page 3 Description page 4 Charging the batteries page 5 Controls and Features page 6 Hi Resolution Mode page 7 Audio

More information

DVB-T Receiver UFD 570/S

DVB-T Receiver UFD 570/S User's Guide DVB-T Receiver UFD 570/S Order No.: 20210035 2 Foreword Foreword Dear customer, This User's Guide is designed to help you to use the extensive functions of your new DVB-T receiver most effectively.

More information

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4.

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4. DTM-HD01 Thank you for buying this encoder modulator. Please read this manual carefully to install, use and maintain the encoder modulator in the best conditions of performance. Keep this manual for future

More information

TABLE OF CONTENTS. 1 GENERAL Description Specifications...3

TABLE OF CONTENTS. 1 GENERAL Description Specifications...3 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER S MANUAL. PROLINK-2 Premium TABLE OF CONTENTS 1 GENERAL...1 1.1 Description...1 1.2 Specifications...3 2 SAFETY RULES...9

More information

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder

More information

DSR 5580 Digital SAT-Receiver

DSR 5580 Digital SAT-Receiver DSR 5580 Digital SAT-Receiver Operating Instructions Operating Instructions Contents Contents...2 General information...4 Safety and installation information...4 Connecting up the receiver...6 Controls,

More information

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL 2. Caution Statements and Table of Contents Table of Contents 2. Caution Statements and Table of contents 3. Important Safety Instructions 4. Important Safety

More information

TDX overview. TDX Headend. Quite simply a revolution. Triax A/S Bjørnkærvej Hornsyld Denmark. System technology. WEB-Configurator.

TDX overview. TDX Headend. Quite simply a revolution. Triax A/S Bjørnkærvej Hornsyld Denmark. System technology. WEB-Configurator. TDX overview System technology Advantage TDX Pool technology Separation between input and output modules Any given input to any given output One input can be used for multiple output modulations Benefit

More information

Before you can install your LCD TV on the wall, you must fi rst remove the base using the steps below:

Before you can install your LCD TV on the wall, you must fi rst remove the base using the steps below: Quick Start Guide English CONTENTS INSTALLING LCD TV ON THE WALL.. TV CHANNEL INSTALLATION........ PRESENTATION OF THE LCD TV...... ACCESSORIES.................... BATTERY INSTALLATION............ REMOTE

More information

Converts any TV to Digital. MFR-300 User Guide

Converts any TV to Digital. MFR-300 User Guide Converts any TV to Digital MFR-300 User Guide Introduction Thank you for choosing this TVonics Freeview box. Record the serial number in the space provided below (the serial number can be found on the

More information

ROHDE&SCHWARZ. Handheld Spectrum Analyser FSH3 100kHz-3GHz Essential tool for measurement of TV transmitters and cable networks. Only 4,999.

ROHDE&SCHWARZ. Handheld Spectrum Analyser FSH3 100kHz-3GHz Essential tool for measurement of TV transmitters and cable networks. Only 4,999. ROHDE&SCHWARZ Handheld Spectrum Analyser FSH3 100kHz-3GHz Essential tool for measurement of TV transmitters and cable networks Only 4,999. 00 nalysis anytime spectrum analyzer for ffective signal invesnumber

More information

Digital Terrestrial Television Receiver USER S MANUAL

Digital Terrestrial Television Receiver USER S MANUAL Digital Terrestrial Television Receiver USER S MANUAL CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol is intended to alert the user to the presence of insulated dangerous voltage within the products

More information

English DMB-118HDMK3

English DMB-118HDMK3 English DMB-118HDMK3 Table of Contents Safety Information...1 System Connection...1 Remote Control...2 First Time Installation...3 Basic Operation...3 Change Channel...3 Volume and Mute...3 Subtitle/Audio

More information