1 Installation guide M C RESOLUTE RESA and REXA absolute angle encoders

2 Contents Product compliance 1 Storage and handling 2 Readhead installation drawing 3 Readhead side cable outlet installation drawing 4 RESA Installation drawing ( A section) 5 Installation drawing ( B section) 6 Select a mounting option 7 Taper mount method 7 Interference fit method 8 REXA Installation drawing 9 Installation 10 Readhead mounting/installation 12 Electrical connections 12 Ring technical specification 12 BiSS-C serial comms 13 FANUC serial comms 14 Mitsubishi serial comms 15 Pansonic/Omron serial comms 16 Yaskawa serial comms 17 Siemens DRIVE-CLiQ Serial comms 18 Interface drawings 19 Dual head installation 20

3 Product compliance C Renishaw plc declares that RESOLUTE complies with the applicable standards and regulations. A copy of the EC Declaration of Conformity is available on request. FCC compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could void the user s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance. Disclaimer RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT. The packaging of our products contains the following materials and can be recycled. Packaging Component Material ISO Recycling Guidance Outer box Inserts Cardboard Polypropylene Low Density Polyethylene Foam Cardboard Not applicable PP LDPE Not applicable Recyclable Recyclable Recyclable Recyclable RoHS compliance Compliant with EC directive 2011/65/EU (RoHS) Bags High Density Polyethylene Bag Metalised Polyethylene HDPE PE Recyclable Recyclable Patents Features of Renishaw s encoder systems and similar products are the subjects of the following patents and patent applications: US IL EP CN US JP GB CN GB JP US CN EP JP US KR CN EP KR US CN EP US KR Further information Further information relating to the RESOLUTE encoder range can be found in the RESOLUTE Data sheets. These can be downloaded from our website and are also available from your local representative. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means without the written prior permission of Renishaw. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc. The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service or Renishaw distributor. 1

4 Storage and handling Readhead RESOLUTE RESA and REXA are non-contact optical encoders that provide good immunity against contaminants such as dust, fingerprints and light oils. However, in harsh environments such as machine tool applications, protection should be provided to prevent ingress of coolant or oil. Ring System Ring only Readhead only N-heptane Acetone Acetone CH 3 (CH 2 ) 5 CH 3 NOTE: Do not use N-heptane on ETR readheads CH 3 COCH 3 Chlorinated Solvents CH 3 COCH 3 Chlorinated Solvents Propan-2-ol CH 3 CHOHCH 3 Methylated Spirits Methylated Spirits Storage Operating Humidity Readhead and DRIVE-CLiQ interface System Standard +80 C -20 C Readhead Standard +80 C 0 C ETR +80 C -40 C UHV +75 C 0 C ETR +80 C -40 C UHV +80 C 0 C Bakeout +120 C DRIVE-CLiQ interface +55 C 0 C Standard and UHV: 95% relative humidity (non-condensing) to EN ETR: 0 C to 60 C, 95% relative humidity decreasing linearly to 40% at 80 C 2

5 Readhead installation drawing (RESA shown) Dimensions and tolerances in mm (Yaw tol. ±0.5 ) 0.31 Set-up LED 10 > 6.5 min R>20 Dynamic bend radius R>10 Static bend radius Ø 4.7 ± typ* 2 mounting holes M3 through, counterbored each side, 3 deep 18 (Roll tol. ±0.5 ) typ* Rideheight 0.8 ±0.15 = 8.6 (Pitch tol. ±0.5 ) ±1 Scale and optical centreline Optical centreline Forward direction of ring (increasing count) irrespective of readhead orientation * Extent of mounting faces = 0.8 ±0.1 mm on 52 mm rings > 10 ±0.1 mm for REXA Recommended thread engagement 5 min (8 including counterbore). Recommended tightening torque 0.5 to 0.7 Nm 3

6 RESOLUTE readhead side cable outlet installation drawing (REXA shown) Dimensions and tolerances in mm 10 ±0.1 > (Yaw tol. ±0.5 ) 0.31 Set-up LED 6.5 min R>20 Dynamic bend radius R>10 Static bend radius Ø 4.7 ± mounting holes M3 x 9 deep counterbored 3 deep typ* typ* 18 (Roll tol. ±0.5 ) Rideheight 0.8 ±0.15 = 3.8 = (Pitch tol. ±0.5 ) ± 1 Scale and optical centreline Optical centreline * Extent of mounting faces = 0.8 ±0.1 mm on 52 mm rings > 10 for RESA Recommended thread engagement 5 min (8 including counterbore). Recommended tightening torque 0.5 to 0.7 Nm Forward direction of ring (increasing count) irrespective of readhead orientation 4

7 RESA Installation drawing ( A section) Dimensions and tolerances in mm Nominal external diameter (mm) DO (mm) DI (mm) Mounting holes DH (mm) N θ N holes equally spaced on PCD ØDH Ø3.5 through c/bore Ø6 x 3 deep N holes equally spaced on PCD ØDH M3 x 0.5 through c/bore Ø3.5 x 4 deep A A Ring rotation to give increasing count θ NOTE: The scale zero position is radially aligned with the centre of the mounting hole to the left of the Renishaw logo. NOTE: θ is the angle between one tapped hole and the adjacent clearance hole. The angle between two clearance holes is 2θ ØDI ØDH ØDO 0.5 x Scale Section A-A 15 ± x * *NOTE: There are no tapped holes on the 489 mm ring IMPORTANT: RESOLUTE readheads must be used with the correct size RESA ring. Ensure matching part numbers when ordering. 5

8 RESA Installation drawing ( B section) Dimensions and tolerances in mm N holes equally spaced on PCD ØDH Ø3.5 through N holes equally spaced on PCD ØDH M3 x 0.5 through A A θ NOTE: The scale zero position is radially aligned with the centre of the mounting hole to the left of the Renishaw logo. NOTE: θ is the angle between one tapped hole and the adjacent clearance hole. The angle between two clearance holes is 2θ. 7 Nominal external diameter (mm) DO (mm) DI (mm) Mounting holes DH (mm) N θ x 45 6 Scale 0.5 Ring rotation to give increasing count 6.5 R0.5 ØDI ØDH ØDO 3 Section A-A 6

9 RESA Select a mounting option Taper mount Interference fit Taper mount method Step 2 u Clean shaft taper and internal taper of RESA as recommended in the storage and handling section. A section u Insert the first screws: For RESA rings with 6, 9 or 18 mounting holes, use 3 equally spaced M3 screws. B section Notes Not applicable Recommended for all installations Enables simplest adjustment. Offers highest accuracy. Enables eccentricity to be compensated. Offers excellent mechanical stability against thermal cycling, shock and vibration. Minimises cost of substrate preparation. Taper mount method Mounting shaft specifications Alternative installation Will not correct eccentricity of the supporting shaft. When using a RESOLUTE ETR the hub should be made of a material with a CTE of between 14 and 18 µm/m/ C. For more information on mounting the ring when using ETR please contact your local Renishaw representative. DT 1* Step 1 7 min 15 ±0.2 For RESA rings with 12, 16 or 20 mounting holes, use 4 equally spaced M3 screws. NOTE: Do not lubricate screws. Recommended screw type M3 x 0.5: ISO 4762/DIN 912 grade 10.9 minimum/ansi B18.3.1M. u Insert the screws so that the RESA is loosely connected to the shaft, then roughly align the ring by eye and touch. u Lightly tighten the screws. Use a Dial Test Indicator (DTI) to check the radial displacement at the screw locations. NOTE: Disregard the radial displacement between the screw locations. DTI Use a DTI with low exertion force to avoid scratching the scale surface. A DTI with a ruby ball stylus is recommended as a further precaution against scratches. *Allow 2 mm for 417 mm, 489 mm and 550 mm rings only Recommended taper roundness Recommended taper diameter (DT) u Adjust the screws to reduce the range of radial displacement. When adjusting, identify the screw location with the lowest radial displacement and tighten that screw, aiming for the average of the highest and lowest indicator readings. u Repeat this process until the DTI readings are within ±5 µm at the screw locations. Diameter (mm) Roundness value (mm TIR) to Recommended surface finish Ra 1.2 NOTE: It is recommended that the mounting surface is a turned, rather than ground finish. DO (mm) DT (mm) DO (mm) DT (mm) DO (mm) DT (mm) DO = Nominal external diameter NOTE: It may be necessary to loosen screws whilst tightening other screws. NOTE: At this stage, the screws should only be lightly tightened (less than 0.5 Nm) to allow further final adjustment. 7

10 RESA Select a mounting option (continued) Taper mount method Step 5 Taper mount method Step 3 Taper mount method Step 4 u Insert the next screws: For RESA rings with 6, 9 or 12 mounting holes, insert all the remaining M3 screws. For RESA rings with 16 mounting holes, insert 3 equally spaced M3 screws. For RESA rings with 18 mounting holes, insert 6 equally spaced M3 screws. For RESA rings with 20 mounting holes, insert 8 equally spaced M3 screws (in four groups of two) between existing screws. u As described in Step 2, adjust all the screws inserted thus far, so that the radial displacement at each screw location is within ±5 µm. u Again, at this stage, the screws should only be lightly tightened (less than 0.5 Nm). NOTE: You may notice that the torque required to achieve the radial displacement tolerance will be slightly higher during step 3 than during step 2. This is normal. u Insert screws into the remaining mounting holes. Diameter (mm) Interference fit method Mounting shaft specifications. When using a RESOLUTE ETR the hub should be made of a material with a CTE of between 14 and 18 µm/m/ C. Contact your local Renishaw representative for more information. Applies to A and B section rings. DO Recommended torque range (Nm) to to DS u Rotate the RESA ring, measuring the radial displacement at all of the screw locations. u Tighten the screw with the lowest radial displacement so that it matches the average radial displacement, whilst ensuring the maximum torque specified in the table is not exceeded. u Again, rotate the RESA ring and re-check the radial displacement at all of the screw locations, tightening the screw with the lowest radial displacement so that it matches the average. u Repeat this process until the radial displacement at all of the screw locations is within ±3 µm and that all screw torques are within the specified range. u Excessive tightening of screws can have a small effect on accuracy. Please contact your local representative for more details. NOTE: 417, 489 and 550 mm rings should be taper mounted only. DO = Nominal external diameter DS = Recommended shaft diameter to enable interference fit *52 mm B section ring = DO (mm) 52* DS (mm)

11 REXA Installation drawing Dimensions and tolerances in mm 10 ±0.1* *NOTE: Graduations are centered within this dimension Scale Nominal external diameter (mm) Dimensions Mounting Holes D1 D2 D3 N D4 θ 52 = = Scale centreline NOTE: The scale zero position is radially aligned with the centre of the mounting hole to the left of the Renishaw logo. A Ring rotation to give increasing count θ D2 D1 D = 52 mm and 57 mm rings have dimple fiducial features and no slots. Section A-A Fiducial marks, 4 positions, to aid installation A N holes Ø6 through equispaced D4 9

12 REXA Installation REXA should be flange mounted onto a flat surface, this eliminates all installation errors except eccentricity, which can be compensated using twin readheads. u Although taper mounting is best for thin cross-section rings, it is not suitable for thick cross-section REXA rings. u The REXA ring should be flange mounted onto a flat surface to minimise 2-per-rev distortion. u Some eccentricity of the ring is acceptable because it will be compensated by the use of twin readheads. u To avoid distorting the scale, the REXA should not be interference fitted. Mounting Step 2 u Clean the mounting face on the lower side of the REXA. Clean the mating surface on the mounting shaft. u Place the REXA onto the mounting shaft, then insert four off M5 screws with flat washers into the four screw holes by the fiducial marks. NOTE: Do not lubricate screws. Recommended screw type M5 x 0.8: ISO 4762/DIN 912 grade 10.9 minimum/ansi B18.3.1M. DO NOT tighten the screws at this point simply engage the threads ensuring that the heads do not touch the ring. Dimple or slot indicates fiducial mark NOTE: If using REXA with RESOLUTE ETR please contact your Renishaw representative. DO NOT INTERFERENCE FIT u Set up a Dial Test Indicator (DTI) to measure the run-out on the REXA ring. Shaft preparation Step 1 u NOTE: At this stage the ring is not firmly fixed, so to avoid causing the ring to shift position, rotate the ring slowly and smoothly. There is a mounting face on the lower side of the REXA ring. A flat surface should be prepared on the mounting shaft to match. The total axial run-out of the mounting surface should be better than 10 µm. N x M5 x 0.8 x 10 deep (<D1-0.75) A 0.01 A D4 u Where the DTI shows the lowest radius reading, gently tap the opposite side of the ring on the edge using a rubber mallet, until the DTI reading is approximately at the mid point of the run-out. u Now find the new lowest radius reading and again tap the opposite side of the ring with a rubber mallet until the DTI reading is at the mid point of the run-out. Use a DTI with low contact force to avoid scratching the scale surface. A DTI with a ruby ball stylus is recommended as a further precaution against scratches. D4 D2 Ø 0.2 A D1 u Continue this process until the run-out of the ring is approximately 30 µm ( inches). This is the initial adjustment. Now adjust to 10 µm at the fiducial points (see overleaf). For dimensions D1, D2, D3, D4 and number of holes N, please refer to ring drawing. D3 10

13 REXA Installation (continued) Mounting Step 3 Adjust ring position until the DTI (dial test indicator) reading at these points agrees to 10 µm. Slot fiducial Alternative method -using adjustment screws It is essential that 4 adjustment screws are used, aligned to the 4 fiducial points (indicated by a slot or dimple mark machined into the front face of the ring). IMPORTANT: To achieve the highest accuracy, the ring must not be distorted. When adjusting the ring position using adjustment screws, always work in opposing pairs, loosening one screw before tightening the other. Once the ring has been set to 10 µm in one plane, loosen both those adjustment screws before adjusting the other plane. For ease of adjustment, 4 off M5 screws with washers should be inserted into the ring and tightened finger-tight. These mounting screws should be fitted in the bolt holes aligned to the 4 fiducial marks. Mounting Step 4 Slot fiducial Take run-out measurements at the opposing fiducial points and centre the ring in that plane to within 10 µm. Next, centre the ring in the other direction to within 10 µm in the same way. Note that the run-out at the slots does not have to equal the run-out at the dimples. Finally, re-check the original plane. Note that 52 mm and 57 mm rings have dimple marks only, so select diametrically opposed dimples as adjustment points. Once the ring is set in both planes fit the remaining M5 screws and torque to 4 Nm. Now adjust the ring position until the DTI (dial test indicator) reading at these points agrees to 10 µm. Dimple fiducial Dimple fiducial Mounting Step 5 u Re-check the run-out at the two slot fiducial points, to ensure the run-out at the two slot points is still better than 10 µm. Adjust if necessary. u Gradually tighten the 4 screws, a quarter-turn at a time so as to avoid moving the position of the ring. Finally, insert the remaining M5 screws and torque all the screws to 4 Nm. u Re-check the run-out at the two slot fiducial points, then at the two dimple fiducial points. The run-out values at the slot fiducial points do not have to match the run-out values at the dimple fiducial points. If the ring has moved position outside the 10 µm limit, the screws must be loosened and the ring adjusted. 11

14 Readhead mounting/installation Electrical connections Mounting brackets The bracket must have a flat mounting surface, enable conformance to the installation tolerances, allow adjustment of the rideheight of the readhead, and be sufficiently stiff to prevent deflection of the readhead during operation. RESOLUTE grounding and shielding Readhead Inner shield Connector Extension cable* Customer electronics 5 V Readhead set-up Ensure that the scale, readhead optical window and mounting face are clean and free from obstructions. To set nominal rideheight, place the readhead spacer with the L shaped aperture under the optical centre of the readhead to allow normal LED function during set-up procedure. Adjust the readhead to maximize the signal strength around the full axis rotation to achieve a green or blue LED. Outer shield 0 V Serial communication signals Readhead set-up LED and DRIVE-CLiQ interface STATUS LED status Blue Green Orange Red Yaw 0 ±0.5 IMPORTANT: The outer shield should be connected to the machine earth (Field ground). The inner shield = should be connected to 0 V at customer electronics only. Care should be taken to ensure that the inner and outer shields are insulated from each other. If the inner and outer shields are connected together, this will cause a short between 0 V and earth, which could cause electrical noise issues. NOTE: Flashing of set-up LED indicates scale reading error. Flashing state is latched for some serial protocols. (Remove power to reset) Roll 0 ±0.5 Pitch 0 ±0.5 IMPORTANT: If the flying lead variant is used or the connector is modified or replaced, the customer must ensure both 0 V cores (White and Green) are connected to 0 V. *For Siemens DRIVE-CLiQ please refer to Siemens DRIVE-CLiQ specifications for maximum cable length. = For UHV there is no inner shield to be connected. RESOLUTE grounding and shielding - Yaskawa protocol only Readhead Connector Extension cable Customer electronics 5 V Serial communication signals Shield 0 V Rideheight 0.8 ±0.15 mm IMPORTANT: The shield should be connected to the machine earth (Field ground). IMPORTANT: If the connector is modified or replaced, the customer must ensure both 0 V cores (White and Green) are connected to 0 V. Ring technical specification (REXA shown) NOTE: The scale zero position is radially aligned with the centre of the mounting hole to the left of the Renishaw logo. Material Coefficient of expansion (at 20 C) 303/304 stainless steel 15.5 ±0.5 µm/m/ C 12

15 BiSS-C serial comms General specifications Power supply (standard and UHV) 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN Ripple 200 mvpp frequency up to 500 khz Sealing (standard) IP64 (UHV) IP30 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration (standard) Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes (UHV) Operating 100 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass (standard) Readhead 18 g Cable 32 g/m (UHV) Readhead 19 g Cable 19 g/m Readhead cable (standard) 7 core, tinned and annealed copper 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life >20 x 10 6 cycles at 20 mm bend radius (UHV) Maximum readhead cable length UL recognised component Silver-coated copper braided single screen FEP core insulation over tin-plated copper wire 10 m For maximum extension cable length, contact your local Renishaw representative Output signals Function Signal Wire colour 9 way D-type Pin 9 way D-type Power 5 V Brown 4, 5 Serial communications 0 V White Green MA+ Violet 2 MA- Yellow 3 SLO+ Grey 6 SLO- Pink 7 Shield Inner* Inner shield 1 For details, refer to BiSS Data sheet L *No inner shield for UHV variant. NOTE: For UHV readhead only flying lead option available. 8, 9 Outer Outer shield Case The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. 13

16 FANUC serial comms General specifications 9 way D-type Power supply 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN Ripple 200 mvpp frequency up to 500 khz Sealing IP64 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes 31 Maximum acceleration of scale with respect to readhead 690 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass Readhead 18 g Cable 32 g/m Readhead cable (standard) 7 core, tinned and annealed copper 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life >20 x 10 6 cycles at 20 mm bend radius 20 way Maximum readhead cable length UL recognised component 10 m For maximum extension cable length, contact your local Renishaw representative Outer shield (connect to machine ground) The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. Lemo Output signals 46.6 Pin Function Signal Wire colour 9 way D-type Lemo 20 way Power 5 V Brown 4, , 20 max Serial White 0 V Green 8, 9 12, 8 12, 14 REQ Violet M16 x communications *REQ Yellow SD Grey *SD Pink Shield Inner Inner shield Outer Outer shield Case Case External NOTE: For Lemo option, mating extension cables and sealing caps are available from your local Renishaw representative. 14

17 Mitsubishi serial comms General specifications Power supply 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated Sealing Ripple RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN mvpp frequency up to 500 khz IP64 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass Readhead 18 g Cable 32 g/m Readhead cable (standard) 7 core, tinned and annealed copper 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life >20 x 10 6 cycles at 20 mm bend radius Output signals Pin Function Signal Wire colour 15 way D-type Power 5 V Brown 7, 8 White 0 V Green 2, 9 Serial MR Violet 10 communications MRR Yellow 1 MD Grey 11 MDR Pink 3 Shield Inner Inner shield 15 Outer Outer shield Case For 2 wire do not connect MD and MDR. 15 way D-type UL recognised component Maximum readhead cable length 1 m* For maximum extension cable length, contact your local Renishaw representative The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential *Lengths above 1 m available on special order. 15

18 Panasonic/Omron serial comms General specifications Power supply (standard and UHV) 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN Ripple 200 mvpp frequency up to 500 khz Sealing (standard) IP64 (UHV) IP30 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration (standard) Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes (UHV) Operating 100 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass (standard) Readhead 18 g Cable 32 g/m (UHV) Readhead 19 g Cable 19 g/m Readhead cable (standard) 7 core, tinned and annealed copper 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life >20 x 10 6 cycles at 20 mm bend radius Output signals Pin Function Signal Wire colour 9 way D-type M12 ( A code) Power 5 V Brown 4, 5 2 White 0 V Green 8, 9 5, 8 Serial REQ+, SD+ Violet 2 3 communications REQ-, SD- Yellow 3 4 Shield Inner* Inner shield 1 1 Outer Outer shield Case Case Reserved Grey 6 7 Do not connect Pink 7 6 *No inner shield for UHV variant. NOTE: For UHV readhead only flying lead option available. 9 way D-type (UHV) Maximum readhead cable length UL recognised component Silver-coated copper braided single screen FEP core insulation over tin-plated copper wire 10 m For maximum extension cable length, contact your local Renishaw representative 31 The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. M AF M12 x 10 16

19 Yaskawa serial comms General specifications Power supply 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated Sealing Ripple RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN mvpp frequency up to 500 khz IP64 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass Readhead 18 g Cable 32 g/m Readhead cable (standard) 7 core, tinned and annealed copper 28 AWG Single shielded, outside diameter 4.7 ±0.2 mm Flex life >40 x 10 6 cycles at 20 mm bend radius Output signals Function Signal Wire colour 9 way D-type Pin 9 way D-type M12 ( A code) Power 5 V Brown 4, 5 2 Serial communications 0 V White Green 8, 9 5, 8 S Violet S Yellow 3 4 Shield Shield Shield Case Case Reserved Do not connect Grey 6 7 Pink 7 6 Maximum readhead cable length UL recognised component 10 m For maximum extension cable length, contact your local Renishaw representative 31 The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. M AF M12 x 10 17

20 Siemens DRIVE-CLiQ serial comms General specifications Power supply (DRIVE-CLiQ system) 24 V 1.8 W maximum (75 24 V), 24 V as per DRIVE-CLiQ specification 24 V power is provided by the DRIVE-CLiQ network NOTE: The Renishaw DRIVE-CLiQ interface must be powered from a 24 V dc supply complying with the requirements for SELV of standard IEC BS EN Ripple 200 mvpp frequency up to 500 khz Sealing (readhead) IP64 (interface) IP67 Acceleration (readhead) Operating 500 m/s 2, 3 axes Shock (readhead and interface) Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration (readhead) Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes (interface) Operating 100 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass Readhead 18 g Cable 32 g/m Interface 218 g Readhead cable 7 core, tinned and annealed copper 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life >20 x 10 6 cycles at 20 mm bend radius Maximum readhead cable length Connector tightening torque UL recognised component Readhead to DRIVE-CLiQ interface 10 m (Refer to Siemens DRIVE-CLiQ specifications for maximum cable length from interface to controller) M12 4 Nm The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. Output signals Signals between readhead and interface Function Signal Wire colour Pin M12 ( A code) Power 5 V Brown 2 White 0 V Green 5, 8 Serial A+ Violet 3 communications A- Yellow 4 Shield Inner Inner shield 1 Outer Outer shield Case Reserved Grey 7 Do not connect Pink 6 Interface output Pin Function Signal M12 ( A code) Power 24 V 1 0 V 5 DRIVE-CLiQ RX+ 3 communications RX- 4 TX+ 7 TX- 6 Shield Case M12 Electrical connections RESOLUTE grounding and shielding AF Readhead Inner shield M12 x 10 Outer shield DRIVE-CLiQ interface DRIVE-CLiQ cable Siemens DRIVE-CLiQ connection IMPORTANT: If reterminating readhead cable care should be taken to ensure that the inner and outer shields are insulated from each other. If the inner and outer shields are connected together, this will cause a short between 0 V and earth, which could cause electrical noise issues. 18

21 Siemens DRIVE-CLiQ interface drawings Dimensions and tolerances in mm Single readhead (A ) Dual readhead (A ) off mounting holes Ø5.5 through off mounting holes Ø5.5 through LED indicators LED indicators M12 8-way female for readhead connection M12 8-way male for DRIVE-CLiQ connection (including power supply) M12 8-way female for readhead connection M12 8-way male for DRIVE-CLiQ connection (including power supply) RDY LED functions Colour Status Description Off Power supply is missing or outside of permissible tolerance range Green Continuous light The component is ready for operation and cyclic DRIVE-CLiQ communication is taking place Orange Continuous light DRIVE-CLiQ communication is being established Red Continuous light At least one fault is present in this component. NOTE: The LED is activated regardless of whether the corresponding messages have been reconfigured Green/Orange or Red/Orange Flashing light Component recognition via LED is activated (p0144) NOTE: Both options depend on the LED status when component recognition is activated via p0144=1 STATUS LED(s) function STATUS displays the readhead set-up status as shown on the readhead set-up LED(s) Blue Green Orange Red 19

22 Siemens DRIVE-CLiQ dual head installation Accuracy The dual head interface is designed for use with two RESOLUTE readheads and REXA ring only and compensates for the effect of bearing wander and eliminates all odd error harmonics including eccentricity. However, even error harmonics such as ovality remain. This results in high angular accuracy to ± 1 arc second, as shown in the accompanying table. REXA diameter 100 mm Total installed accuracy (with 2 readheads) ±1 arc second 75 mm ±1.5 arc second 57 mm ±2 arc second For optimum accuracy performance, the readheads should be diametrically opposite each other so that the optical centre lines are 180 apart. However if this is not possible due to mounting constrictions, or for partial arc applications, the readheads should be mounted as close to this as possible; please contact your local Renishaw representative to find out what accuracy you can expect if this is the case. Electrical connections For high speed applications, it is recommended to use similar cable lengths for each readhead to ensure the readings are simultaneous and achieve the highest accuracy. The DRIVE-CLiQ cable is a proprietary part and is not supplied by Renishaw plc. Readhead Inner shield Interface output For readheads (RH1 and RH2) mounted such that the angle between them is θ. Readhead Outer shield Inner shield Dual head DRIVE-CLiQ interface Siemens DRIVE-CLiQ connection Ring rotation to give increasing count DRIVE-CLiQ cable RH1 Outer shield Summary of procedure θ/2 θ Install both readheads on mounting surfaces. Connect both readheads to dual head interface and connect interface to controller RH2 Output Supply power to the controller and interface, adjust each readhead such that both readheads have good signal levels around the ring (Green or Blue indication). The dual head DRIVE-CLiQ interface takes simultaneous readings from both readheads and calculates the mean of them. The output is therefore at an angle of θ/2 and is in the position shown when the scale is orientated with increasing count as shown. Acknowledge any errors on the controller that may have occured during installation. 20

23 Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire GL12 8JR United Kingdom T +44 (0) F +44 (0) E uk@renishaw.com RSLM high accuracy linear encoder For worldwide contact details, please visit our main website at RENISHAW and the probe symbol used in the RENISHAW logo are registered trade marks of Renishaw plc in the United Kingdom and other countries. apply innovation and names and designations of other Renishaw products and technologies are trade marks of Renishaw plc or its subsidiaries Renishaw plc All rights reserved Issued 0618 *M *

Installation guide M F RESOLUTE

Installation guide M F RESOLUTE Installation guide M-9553-9433-06-F RESOLUTE RSLM high accuracy RTLA-S linear absolute encoder linear encoder system Contents Product compliance 1 Storage and handling 2 Installation drawing: RESOLUTE

More information

Installation guide M C

Installation guide M C Installation guide M-9553-9128-05-C RESOLUTE RSLM high accuracy RSLA/RELA linear encoder high accuracy absolute linear encoder Contents Product compliance 1 Storage and handling 2 Installation drawing:

More information

Installation guide M A. VIONiC RESM20 / REST20 angle encoder system

Installation guide M A. VIONiC RESM20 / REST20 angle encoder system Installation guide M-6195-9218-02-A VIONiC RESM20 / REST20 angle encoder system Contents Product compliance 1 Storage and handling 2 RESM20/REST20 installation drawing ( A section) 3 RESM20/REST20 installation

More information

QUANTiC RESM40 angle encoder system

QUANTiC RESM40 angle encoder system Installation guide M-9417-9201-01-A RSLM high accuracy linear encoder QUANTiC RESM40 angle encoder system Contents Product compliance 1 Storage and handling 2 RESM40: Installation drawing ( A section)

More information

RESOLUTE absolute optical encoder with Panasonic serial communications

RESOLUTE absolute optical encoder with Panasonic serial communications L-9517-9460-07-A RESOLUTE absolute optical encoder with Panasonic serial communications True absolute non-contact optical encoder system: no batteries required Wide set-up tolerances for quick and easy

More information

Installation guide M A

Installation guide M A Installation guide M-97-9000-03-A TONiCRSLM T20x1 high accuracy RESD linear angle encoder encoder system Contents Product compliance 1 Storage and handling 2 Installation drawing ( A section RESD) 3 TONiC

More information

Installation guide M D

Installation guide M D Installation guide M95391103D TONiCRSLM T20x1 high accuracy RESM linear angle encoder encoder system Contents Product compliance 1 Storage and handling 2 RESM installation drawing ( A section) 3 RESM installation

More information

QUANTiC RKLC40-S incremental linear encoder system

QUANTiC RKLC40-S incremental linear encoder system Installation guide M-9417-9238-01-A RSLM high accuracy linear encoder QUANTiC RKLC40-S incremental linear encoder system Contents Product compliance 1 Storage and handling 2 QUANTiC readhead installation

More information

Installation guide M A

Installation guide M A Installation guide M-9562-9063-02-A RGH25F RSLM high RGS20 accuracy linear encoder system Contents Product compliance 1 Storage and handling 2 RGH25F readhead installation drawing 3 REF interface installation

More information

DOP (dual output) encoder system

DOP (dual output) encoder system Installation guide M-9653-9278-01-D (dual output) encoder system RSLM high accuracy linear encoder Renishaw plc declares that complies with the applicable standards and regulations. A copy of the EC Declaration

More information

TONiC T103x RTLC-S linear encoder system

TONiC T103x RTLC-S linear encoder system Installation guide M959901303B RSLM high accuracy linear encoder TONiC T3x RTLCS linear encoder system Contents Product compliance Storage and handling TONiC readhead installation drawing RTLCS installation

More information

TONiC T100x RGSZ linear encoder system

TONiC T100x RGSZ linear encoder system Installation guide M9653915405B RSLM high accuracy linear encoder TONiC T0x RGSZ linear encoder system Contents Product compliance 1 Storage and handling 2 TONiC readhead installation drawing 3 RGSZ20S

More information

TONiC T103x RTLC/FASTRACK linear encoder system

TONiC T103x RTLC/FASTRACK linear encoder system Installation guide M9589900203C RSLM high accuracy linear encoder TONiC T3x RTLC/FASTRACK linear encoder system Contents Product compliance 1 Storage and handling 2 TONiC readhead installation drawing

More information

LM10 linear magnetic encoder system

LM10 linear magnetic encoder system RLS merilna tehnika d.o.o. Cesta II. grupe odredov 5 SI-161 Ljubljana - Dobrunje Slovenia T +86 1 57100 F +86 1 5719 E mail@rls.si www.rls.si Installation guide Issue 4, 14 th January 009 LM10 linear magnetic

More information

ATOM miniature encoder system

ATOM miniature encoder system L70D ATOM miniature encoder system ATOM is the world s first miniature encoder with filtering optics, providing improvements in dirt immunity, signal stability and reliability for linear and rotary applications.

More information

Installation guide H A. OMI-2H optical machine interface

Installation guide H A. OMI-2H optical machine interface Installation guide H-5157-8504-01-A OMI-2H optical machine interface 2016 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other

More information

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach NEW DRS: Incremental encoders, number of lines and zero pulse width freely programmable DRS: s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

ATOM miniature encoder system

ATOM miniature encoder system L70A ATOM miniature encoder system ATOM is the world s first miniature encoder with filtering optics, providing improvements in dirt immunity, signal stability and reliability for linear and rotary applications.

More information

User guide M A. Advanced Diagnostic Tool ADTi-100 and ADT View software

User guide M A. Advanced Diagnostic Tool ADTi-100 and ADT View software User guide M-6195-9413-02-A Advanced Diagnostic Tool ADTi-100 and ADT View software Contents 1 General information 1 1.1 Overview 1 1.2 Product compliance 2 1.3 Minimum requirements 2 1.4 General specifications

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation... Li nearenc oder s wi t httlout put Us ermanual Index 1.0 Introduction..........................2 This Manual...........................2 2.0 Safety Summary......................3 Terms in this Manual....................3

More information

Up to 85% higher Service Life due to efficient sealing method.

Up to 85% higher Service Life due to efficient sealing method. Robot Accessories Feeding through Up to 85% higher Service Life due to efficient sealing method. 346 Robot Accessories Feeding through Feeding through DDF 2 Rotary Feed-through Series Size Page DDF 2 348

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P n n n n n Compact design: 59 mm mounting depth for single or multiturn Aids for start up and operation: diagnostic LED, preset key with optical response Parameterization: Resolution, code type, direction,

More information

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH USER GUIDE AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH Electromagnetic Compatibility (EMC) This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in

More information

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

MAGNETIC TAPE. Series MB. incremental scale. Key-Features: MAGNETIC TAPE incremental scale Series MB Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...3 Installation Instruction...3 Digital Displays...4 Order Code...5 - Available

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

OM2000N INSTALLATION MANUAL

OM2000N INSTALLATION MANUAL OM2000N INSTALLATION MANUAL 2 1 Figure A 1 2 Laser Beam Output Window Power Cable 821001342 (Rev. B) DESCRIPTION The OM2000N oscillating mirror is an accessory for the 2000N family laser scanners: DS2100N,

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4... LVDT Inductive Position Transducer Series SM ø12 mm ranges 2...200 mm linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6 out: AC, 0...10 V, 0...5 V, 4...20 ma with external or integrated cable electronics repeatability

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0109-001 PRODUCT REVISION: 1 PNP202 Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the PNP202 Interconnect Box is greatly appreciated. We are sure you will find it

More information

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide Product Information LS 1679 Incremental Linear Encoder with Integrated Roller Guide February 2007 LS 1679 Incremental linear encoder for measuring steps to 5 µm or 1 µm Integrated wear-free roller guide

More information

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71. Optical SERIES 61K High Resolution, 4-Pin FEATURES 25, 32, 50, 64, 100, 128 and 256 Cycles per Revolution Available Sealed Version Available Rugged Construction Cable or Pin Versions 10 Million Rotational

More information

ABS AT1100 Series. Assembly Type ABS AT Series Absolute Scale Unit (Standard Type) ABS AT Effective length Interface specifications

ABS AT1100 Series. Assembly Type ABS AT Series Absolute Scale Unit (Standard Type) ABS AT Effective length Interface specifications Assembly Type ABS AT Series (Standard Type) (esolution 0.05μm Specification) Features This series has adopted a new structure not easily subject to infiltration of coolant and a dust-proof rubber highly

More information

DKS 40: Incremental Encoder

DKS 40: Incremental Encoder DKS 4: Incremental Encoder By adopting highly successful Mini- Disc technology, the DKS 4 is extremely robust and can resist high levels of shock and vibration. Besides has the DKS 4 a very high protection

More information

Type SCH94FO. Type SCH94FO. Description

Type SCH94FO. Type SCH94FO. Description Type SCH94FO Hollow Shaft Fiber Optic Encoder - Ø 94 mm Dual Output Option (Digital & Fiber Optic) Fiber Optic Transmission up to 2,000 meters (~ 1.25 miles) No Degradation of Encoder Signal from Electrical

More information

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. output 25 bit, Gray-coded clock rate: 62.5 KHz 1 MHz Single or multiturn, length

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

Three Axis Digital Readout System

Three Axis Digital Readout System NEWALL MEASUREMENT SYSTEMS C80 Three Axis Digital Readout System CONTENTS 2 SPECIFICATIONS 3 CONNECTIONS 4 MOUNTING 4 Arm Mounting (Non-adjustable) 4 Arm Mounting (Adjustable) 5 Face Mounting (Adjustable)

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR Description SE22HR is a very high performance hollow shaft encoder; a high resolution is achievable in a small space with a good performance/price

More information

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads Product Information RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads May 2014 RIQ 425 Absolute rotary encoders Synchro flange 01C Solid shaft for separate shaft

More information

HD-One DX/DX500 HDMI Extender

HD-One DX/DX500 HDMI Extender HD-One DX/DX500 HDMI Extender User Manual Version 2.0 tvone 2791 Circleport Drive, Erlanger, KY 41018, USA. Americas: 859-282-7303 EMEA: +44 (0) 1843 873322 Email: tech.usa@tvone.com www.tvone.com CSG-DX-500

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement

More information

Accessories. Servo Motors. Servo Motors B-45. Accessories

Accessories. Servo Motors. Servo Motors B-45. Accessories Servo Motors Servo Motors Accessories Accessories Introduction NX Accessories Page Cables B-46 Flexible Couplings B-50 Control Module B-51 Data Setting Software B-51 Accessory Sets B-52 Regeneration Units

More information

ABS ST700 Compact Type Series

ABS ST700 Compact Type Series Separate Type ABS ST Series (High environmental resistance type) ABS ST700 Compact Type Series Features Scale base type Absolute measurement with separate type scales Non-contact detection is optimal for

More information

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch HDMI Extender over Single CAT 6 Cable with IR Control Model 103002 Extend HDMI audio and video connections up to 300 feet Utilize existing Cat 6 wiring for an easy installation Add up to 8 additional receivers

More information

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information M8 and M Sensor Connectors XS_-EU For a wide range of applications the XS_-EU family of M8 and M sensor connectors provides the high performance and features making the family the ideal choice for standard

More information

Product Data Sheet 8506 VW-691

Product Data Sheet 8506 VW-691 The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

Ø50mm Shaft Multi-Turn Absolute Type

Ø50mm Shaft Multi-Turn Absolute Type Ø50mm Shaft Multi-Turn Absolute Type Diameter Ø50mm Shaft Type Multi-Turn Absolute otary Encoder Features Total 23-bit resolution (8388608-division) of 10-bit single-turn (1024-division) and 13-bit multi-turn

More information

Installation and user s guide H A. OMI - SSR optical machine interface

Installation and user s guide H A. OMI - SSR optical machine interface Installation and user s guide H-2000-5165-01-A OMI - SSR optical machine interface 2002 Renishaw. All rights reserved. Renishaw is a registered trademark of Renishaw plc. This document may not be copied

More information

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 16 bits singleturn Process value in 32 bit telegram 3 error bits 16 bits singleturn 15

More information

HARTING Ethernet cabling cables and connectors, 4 wire

HARTING Ethernet cabling cables and connectors, 4 wire Industrial Cat. 5e Standard cable, 4-wire Type A for permanent installation or to build-up PROFINET system cables PVC X 8 wire X Cat. 5e X Cat. 6 Cat. 6 A Cat. 7 Cable structure Core structure Wire insulation

More information

E3/DS3 Fibre Extender

E3/DS3 Fibre Extender User Manual E3/DS3 Fibre Extender Black Box Network Services 464 Basingstoke Road, Reading, Berkshire, RG2 0BG Tech: 0118 965 6000 www.blackbox.co.uk CONTENTS 1 Introduction 1 1.1 About the products 1

More information

MKH 8060 Directional studio microphone

MKH 8060 Directional studio microphone MKH 8060 Directional studio microphone Instruction manual Contents Contents Important safety information... 2 The MKH 8060... 3 Delivery includes... 4 Product overview... 5 Putting the MKH 8060 into operation...

More information

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1 Content 1. Company Profile... 3 2. Product Introduction... 3 3. Operation Instruction...

More information

Product Data Sheet 4656 ZW

Product Data Sheet 4656 ZW The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment) OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for

More information

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features Description Page 1 of 8 The EM1 is a transmissive optical encoder module designed to be an improved replacement for the HEDS-9000 series encoder module. This module is designed to detect rotary or linear

More information

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151 Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features Description Page 1 of 8 The EM1 is a transmissive optical encoder module. This module is designed to detect rotary or linear position when used together with a codewheel or linear strip. The EM1 consists

More information

ENC - LKE51 - L I B

ENC - LKE51 - L I B ENC-LKE51 Linear Magnetic Encoder FEATURES DESCRIPTION LKE51 ORDERING INFORMATION Resolutions: 5, 10, 25, and 50μm Linear Travel Speed: Up to 16m/s Standard Sensor for Linear and Rotary Axis Gap Clearance

More information

WLS27 Multicolor LED Strip Light with EZ-STATUS

WLS27 Multicolor LED Strip Light with EZ-STATUS WLS7 Multicolor LED Strip Light with EZ-STATUS Instruction Manual Banner's WLS7 Multicolor LED Strip Light has a sturdy aluminum housing and is encased in a shatterproof, UV-stabilized, copolyester shell,

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/ Connectors Introduction 2004 Automatic Connector. All rights reserved. pdf 1.0 4-13-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable

More information

All Control Electronics, No Electronics. And Host System Connections M06 Industrial-Grade Fiber Optic Cabling (Recommended)

All Control Electronics, No Electronics. And Host System Connections M06 Industrial-Grade Fiber Optic Cabling (Recommended) MR314 ZapFree Hollow Shaft FIBER OPTIC ROTARY ENCODER MICRONOR automation components Products The MR314 ZapFree High Resolution (1024ppr) Hollow Shaft Rotary Encoder is an entirely passive, intrinsically

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2 last updated: 2007-03-08 OPERATING MANUAL DMX Demultiplexer 3012B Mk2 (C) SOUNDLIGHT 1995-2007 * ALL RIGHTS RESERVED * NO PART OF THIS MANUAL MAY BE REPRODUCED, DUPLICATED OR USED COMMERCIALLY WITHOUT

More information

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense

More information

Cables for robot applications

Cables for robot applications Cables for robot applications 67 Primary cables Robot primary cable Cable design Internal conductor Special conductor Strand class VI (super-fine wire) Highly flexible Core insulation TPM or PUR Core identification

More information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Installation. SAPTF33xx-1xx in the Network. Standard Configuration SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device

More information

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT) MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT) TECHNICAL DATA Measurement taken Position read sampling time (typical) Shock test DIN IEC68T2-27 Vibrations DIN

More information

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE MANUAL PART NUMBER: 400-0133-001 PRODUCT REVISION: 0 CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL... 2 INSTALLATION...

More information

CATEGORY 6 CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality

More information

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual 100Base-FX Multi-mode to 100Base-FX Single Mode Converter NXF-708 Series User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0 AN2 Series 900tvl CMOS Technology High Resolution Sensor P/N 01.BSM.16.2000030 V1.0 Product Made in China under ISO9001 & ISO1400 standards Manual Printed in China v1.0 elinetechnology.com CAUTION RISK

More information

Linear Probe Encoder Page 1 of 7. Description. Features

Linear Probe Encoder Page 1 of 7. Description. Features Page 1 of 7 Description The PE series linear plunger-style optical encoder has a machined aluminum enclosure. The PE provides either single-ended or differential quadrature encoder output in a convenient

More information

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders Scott Hewitt, President SICK STEGMANN, INC. Dayton, OH www.stegmann.com sales@stegmann.com 800-811-9110 The

More information

Product Data Sheet 4656 EZ

Product Data Sheet 4656 EZ The engineer's choice 4656 EZ INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE MANUAL PART NUMBER: 400-0133-002 CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL... 2 INSTALLATION... 2 CLEANING... 2 FCC / CE NOTICE...

More information

Installation and user s guide M A. HS20 installation guide

Installation and user s guide M A. HS20 installation guide Installation and user s guide M-8003-3192-04-A HS20 installation guide Document Information Document number: M-8003-3192-04-A Issue date: September 2017 2011-2017 Renishaw plc All rights reserved Care

More information

TruVision High Definition TVI Vandal Dome Installation Guide

TruVision High Definition TVI Vandal Dome Installation Guide TruVision High Definition TVI Vandal Dome Installation Guide TVD-2402/TVD-4402 TVD-2404/TVD-4404 P/N 1072937-EN REV A ISS 12MAR15 Content Product overview 3 Camera description 5 Installation 7 Programming

More information

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-001 PRODUCT REVISION: 1 TNP100 Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are

More information

Magnetic Sensor - Incremental EHP

Magnetic Sensor - Incremental EHP small design: 12 x 13 x 35 mm stainless steel case resolution up to 0,5 μm; hysteresis ± 1μm pole pitch:1; 2 mm output signal: Digital (TTL-RS422) or analog (1 Vpp) direct connection to control / display

More information

EZ-STATUS WLS28-2 Multicolor LED Strip Light

EZ-STATUS WLS28-2 Multicolor LED Strip Light EZ-STATUS WLS8- Multicolor LED Strip Light Datasheet Banner's WLS8- Multicolor LED Strip Lights have sturdy aluminum housings, shatterproof windows, and environmental ratings that make it ideal for harsh

More information

EZ-LIGHT K30L Series With Independent Push Button Contact

EZ-LIGHT K30L Series With Independent Push Button Contact EZ-LIGHT K0L Series With Independent Push Button Contact Datasheet Compact with One, Two, or Three s and a Momentary Push Button Output Rugged, cost-effective and easy-to-install multicolor indicator light

More information