1 Close Coupled Catalog /US 81
2 Performance Information The Parker close coupled electric motor/pump provides exceptional performance and compact size at an economical price. lso, with the elimination of the mounting adaptor and coupling required for installation to standard motors, problems associated with misalignment are virtually eliminated. Features Pump installed to motor Saves labor, hardware dollars. Option of steel band or cast iron housing with finned construction which provides excellent heat dissipation. Internal spline ccepts SE, or shafts, offers superior engagement characteristics. SE pilot sizes Offers a variety of motor/pump combinations. Elimination of Mounting daptor More compact package, less costly means of mounting pump to motor. Eliminates potential for misalignment. Installation Information motor by utilizing pump performance curves in piston pump or gear pump catalogs. When installing pump in the field, make sure spline socket is fully packed with high pressure lubricant. lways check incoming voltage to match wiring at motor conduit box. Upon startup, take an amperage draw reading at system full flow and full pressure cycle. Make sure that does not exceed max amperage draw stated on motor nameplate. Refer to pump catalog for installation data pertaining to inlet conditions, max operating temperatures and recommended filtration parameters. Schematic Symbol M Specifications s Horsepower Ratings: Speed Ratings: Voltage: Frequency: Type: Insulation Class: Temperature Rating: or M 1/2, 3/4, 1 HP, 1 Phase 60 Hz, 1, 1.5,2, 3,.5, 7.5, 10 HP, 3 Phase 50/60 Hz 1725 RPM (60 Hz) 1425 RPM (50 Hz) See Performance Data 60, 50/60 Hz TEFC 40 C, mb. Cont. Mounting: SE, Spline 20/40 D.P. SE, Spline 16/32 D.P. SE, 13 Tooth Spline 16/32 D.P. Frame 143/1 TCZ Steel and s Cast Iron s 182/ / /184 1 TCZ TYZ TYZ TYZ HP SE Mount SE Mount SE Mount Standard s vailable from Stock. 82
3 Catalog HY /US Dimensions.5,.75, 1 HP CC, Single Phase Steel and 1 TCZ Frame SE Pump Mount (293.4) (.75, 1 HP-143TCZ) (268) (.5 HP-143TCZ) 3/8-16UNC-2 THR'D x.56 DEEP TYP. 4 PLCS. ON 5.88 (131.7).C. C (THR D 4 PLCS.) (.C. ) ( ) 7.16 (181.9) 60 HZ OPERTION NMEPLTE (124.08) (123.57) 9.05 (229.87) 3.75 (95.3) 5.25 (133.3) D (INT. SPLINE) 6.84 (173.7) (88.9) (87.4) 5.94 (150.8) 4.00 (101.6).38 (9.6) STNDRD CONDUIT LOCTION F2 CONDUIT- OPPOSITE SIDE.34 (8.6) 6 PLCES 4.18 (106) 6.50 (165.1).16 (4.1) SE MOUNT - SPLINE & FCE DETIL X CHMFR..562 (14.3) INTERNL INVOLUTE SPLINE SPLINE PITCH 20/40 Single 60 Hz Operation Phase 115/230 Volts s 1725 RPM, 1 PH Model HP S.F. F.L. mps Number ft.-lbs. MES1N6C / MES1N6C / MESC1N6C / C D MES1N6C.5 HP - 1TCZ MES1N6C.75 HP - 1TCZ SE /16-18UNC 20/40 Pitch MESC1N6C 1 HP - 1TCZ x.63 Deep CUTION: MOTOR INTERNL SPLINE MUST E PCKED WITH HIGH PRESSURE LURICNT GRESE PRIOR TO INSTLLTION OF PUMP. SE accepts: PZG1 **** 83
4 Catalog HY /US Dimensions 1, 1.5, 2, 3 HP CC Steel and 1 TCZ Frame SE, SE Pump Mount (351) (3HP-1TCZ) (315.9) (1.5, 2HP-1TCZ) 3/8-16UNC-2 THR'D x.56 DEEP TYP. 4 PLCS. ON 5.88 (149.5).C. C (THR D 4 PLCS.) (.C. ) ( ) (268.2) (1HP-1TCZ) 50 HZ NMEPLTE 5.25 (133.3) D (INT. SPLINE) 7.19 (182.6) 60 HZ OPERTION NMEPLTE 5.94 (150.8) 4.00 (101.6).38 (9.6) STNDRD CONDUIT LOCTION F2 CONDUIT- OPPOSITE SIDE (124.08) (123.57).88 (22.4) 2 PLCS..34 (8.6) 6 PLCES 4.25 (107.9) 6.50 (165.1) 6.84 (173.7) (88.9) (87.4).16 (4.1) SE MOUNT - SPLINE & FCE DETIL SE MOUNT - SPLINE & FCE DETIL X CHMFR. X CHMFR..562 (14.3) INTERNL INVOLUTE SPLINE.800 (20.3).750 (19.1) INTERNL INVOLUTE SPLINE D SPLINE PITCH 20/40 C D MESC1P7C 1 HP - 1TCZ MESD1P7C 1.5 HP - 1TCZ SE /16-18UNC 20/40 Pitch MESE1P7C 2 HP - 1TCZ x.63 Deep MESF1P7C 3 HP - 1TCZ MESC2P7C 1 HP - 1TCZ MESD2P7C 1.5 HP - 1TCZ SE /8-16UNC MESE2P7C 2 HP - 1TCZ x.88 Deep MESF2P7C 3 HP - 1TCZ CUTION: MOTOR INTERNL SPLINE MUST E PCKED WITH HIGH PRESSURE LURICNT GRESE PRIOR TO INSTLLTION OF PUMP. SE accepts: PZG1 **** SE accepts: H Gear Pump ** PZG2 **** PVP16 Piston Pump ** 84
5 Dimensions 1, 1.5, 2, 3 HP CC Cast Iron 1 TCZ Frame SE Pump Mount 7.48 (190.0) SE MOUNT - SPLINE & FCE DETIL X CHMFR..800 (20.3).750 (19.1) INTERNL INVOLUTE SPLINE D C D MEC2P7C 1 HP - 1TCZ MED2P7C 1.5 HP - 1TCZ SE /8-16UNC MEE2P7C 2 HP - 1TCZ x.88 Deep MEF2P7C 3 HP - 1TCZ CUTION: MOTOR INTERNL SPLINE MUST E PCKED WITH HIGH PRESSURE LURICNT GRESE PRIOR TO INSTLLTION OF PUMP. SE accepts: H ** Gear Pump PZG2 **** PVP16 ** Piston Pump 85
6 Catalog HY /US Dimensions 3, 5 HP CC Steel and 182/184 TYZ Frame SE, SE Pump Mount C (THR D 4 PLCS.) 15.0 (381) (5HP-184TYZ) 13.5 (342.9) (3HP-182TYZ) 50 HZ NMEPLTE 5.88 (149.4) (.C. ) ( ) D (INT. SPLINE) 8.50 (215.9) 60 HZ OPERTION NMEPLTE 8.44 (214.4) (114.3) (112.8).50 (12.7) 4.50 (139.7) 5.50 (114.3).50 (12.7) 3.19 (81) STNDRD CONDUIT LOCTION F2 CONDUIT- OPPOSITE SIDE 1.06 (26.9) 3.75 (95.3) 4.88 (123.9) 3.75 (95.3) 8.62 (218.9).406 TYP.-6 PLCS..16 (4.1) SE MOUNT - SPLINE & FCE DETIL SE MOUNT - SPLINE & FCE DETIL X CHMFR. X CHMFR..800 (20.3).750 (19.1) INTERNL INVOLUTE SPLINE D 1.25 (31.75) MIN INTERNL INVOLUTE SPLINE D NO. TEETH 13 C D MESG2P7C 3 HP - 182TYZ SE /8-16UNC MESH2P7C 5 HP - 184TYZ x.75 Deep MESG3P7C 3 HP - 182TYZ SE /2-13UNC MESH3P7C 5 HP - 184TYZ x.75 Deep 13 Tooth CUTION: MOTOR INTERNL SPLINE MUST E PCKED WITH HIGH PRESSURE LURICNT GRESE PRIOR TO INSTLLTION OF PUMP. SE accepts: H ** Gear Pump PZG2 **** PVP16 ** Piston Pump SE accepts: M F Gear Pump ** PZG3 2 Gear Pump ***** PVP23/33/41/48 Piston Pump ** 86
7 Catalog HY /US Dimensions 3, 5 HP CC Cast Iron 182/184 TYZ Frame SE, SE Pump Mount C (THR D 4 PLCS.) STNDRD CONDUIT LOCTION F2 CONDUIT-OPPOSITE SIDE (320.5) 7.13 (181.1) (.C. ) ( ) D (INT. SPLINE) 9.50 (241.3) 8.50 (215.9) 50 HZ OPERTION NMEPLTE 60 HZ OPERTION NMEPLTE 9.25 (234.9) 1.06 (40.6) (114.3) (112.8).50 (12.7) TYP (88.9) 5.50 (139.7) 3.19 (81).406 (10.3) TYP 8 PLCS (95.3) 5.75 (146.1) 8.62 (218.9) 3.75 (95.3).38 (9.6) SE MOUNT - SPLINE & FCE DETIL SE MOUNT - SPLINE & FCE DETIL X CHMFR. X CHMFR..800 (20.3).750 (19.1) INTERNL INVOLUTE SPLINE D 1.25 (31.75) MIN INTERNL INVOLUTE SPLINE D NO. TEETH 13 C D MEG2P7C 3 HP - 182TYZ SE /8-16UNC MEH2P7C 5 HP - 184TYZ x.75 Deep MEG3P7C 3 HP - 182TYZ SE /2-13UNC MEH3P7C 5 HP - 184TYZ x.75 Deep 13 Tooth CUTION: MOTOR INTERNL SPLINE MUST E PCKED WITH HIGH PRESSURE LURICNT GRESE PRIOR TO INSTLLTION OF PUMP. SE accepts: H ** Gear Pump PZG2 **** PVP16 ** Piston Pump SE accepts: M ** F Gear Pump PZG3 ***** 2 Gear Pump PVP23/33/41/48 ** Piston Pump 87
8 Catalog HY /US Dimensions 7.5, 10 HP CC Steel and 213/215 TYZ Frame SE, SE Pump Mount (402.3) (10HP-215TCZ) (373.6) (7.5HP-213TCZ) 50 HZ NMEPLTE 8.05 (204.4) 2.41 (61.2) C (THR D 4 PLCS.) (.C. ) ( ) D (INT. SPLINE) (258.6) 60 HZ OPERTION NMEPLTE (254.7) 1.06 (26.9) 2 PLCS (133.3) (131.8).50 (12.7) STNDRD CONDUIT LOCTION F2 CONDUIT- OPPOSITE SIDE 5.50 (139.7) 7.00 (177.8).50 (12.7) 3.67 (93.2).406 (10.3) 6 PLCES 6.79 (172.5) 4.25 (107.9) 9.50 (241.3) 4.25 (107.9).22 (5.6) SE MOUNT - SPLINE & FCE DETIL SE MOUNT - SPLINE & FCE DETIL X CHMFR. X CHMFR..800 (20.3).750 (19.1) INTERNL INVOLUTE SPLINE D 1.25 (31.75) MIN INTERNL INVOLUTE SPLINE D NO. TEETH 13 C D MESJ2P7C 7.5 HP - 213TYZ SE /8-16UNC MESK2P7C 10 HP - 215TYZ x.75 Deep MESJ3P7C 7.5 HP - 213TYZ SE /2-13UNC MESK3P7C 10 HP - 215TYZ x.75 Deep 13 Tooth CUTION: MOTOR INTERNL SPLINE MUST E PCKED WITH HIGH PRESSURE LURICNT GRESE PRIOR TO INSTLLTION OF PUMP. SE accepts: H Gear Pump ** PZG2 **** PVP16 Piston Pump ** SE accepts: M ** F Gear Pump PZG3 **** PVP23/33/41/48 ** Piston Pump 88
9 Performance Data Steel and 1 TCZ Frame SE Pump Mount Single Phase s 60 Hz Operation 115/230 Volts 1725 RPM 1 PH Model Number HP S.F. F.L. mps MES1N6C / MES1C6C / MESC1N6C / Steel and 143/1 TCZ Frame SE and SE Pump Mount Three Phase 60 Hz Operation 50 Hz Operation s /460 Volts 1725 RPM 3 PH 190/ Volts 1425 RPM 3 PH Model Number HP S.F. F.L. mps S.F. F.L. mps MESC*P7 * / / MESD*P7 * / / MESE*P7 * / / MESF*P7 * / / Cast Iron 1 TCZ Frame SE Pump Mount Three Phase 60 Hz Operation 50 Hz Operation s /460 Volts 1725 RPM 3 PH 190/ Volts 1425 RPM 3 PH Model Number HP S.F. F.L. mps S.F. F.L. mps MEC2P7 * / / MED2P7 * / / MEE2P7 * / / MEF2P7 * / /
10 Performance Data Steel and 182/184 TYZ Frame SE and SE Pump Mount Three Phase 60 Hz Operation 50 Hz Operation s /460 Volts 1725 RPM 3 PH 190/ Volts 1425 RPM 3 PH Model Number HP S.F. F.L. mps S.F. F.L. mps MESG * P7 * / / MESH * P7 * / / Cast Iron 182/184 TYZ Frame SE and SE Pump Mount Three Phase 60 Hz Operation 50 Hz Operation s /460 Volts 1725 RPM 3 PH 190/ Volts 1425 RPM 3 PH Model Number HP S.F. F.L. mps S.F. F.L. mps MEG * P7 * / / MEH * P7 * / / Steel and 213/215 TYZ Frame SE and SE Pump Mount Three Phase 60 Hz Operation 50 Hz Operation s /460 Volts 1725 RPM 3 PH 190/380 Volts 1425 RPM 3 PH Model Number HP S.F. F.L. mps S.F. F.L. mps MESJ * P7 * / / MESK * P7 * / / This motor is derated to Hz with S.F. 90
11 Ordering Information ME Pump Model Number Horsepower Pump Voltage Frequency Options Design (See Notes 1, 2 & 3) Electric Frame Mounting Series & Type ll motors are 4 pole design (i.e RPM [60 Hz] 1500 RPM [50 Hz]) 1 Pump Mounting, 9-Tooth Spline 2, 9-Tooth Spline 3, 13-Tooth Spline C F Options With ase F2 Conduit Voltage N* 115/230 Volts 1 ph P /460 Volts 3 ph Q** 575 Volts 3 ph *115/230 VC, 1PH, 60 Hz Only ** 575 VC, 3 PH, 60 Hz Only Frequency 5 50 Hz 6* 60 Hz 7 50/60 Hz *115/230 VC, 1PH, 60 Hz Only HP, Frame & Type Reference Pump Mounting S*.5 HP, 143/5 TCZ, steel band S*.75 HP, 143/5 TCZ, steel band SC 1 HP, 143/5 TCZ, steel band C 1 HP, 143/5 TCZ, cast iron SD 1.5 HP, 143/5 TCZ, steel band D 1.5 HP, 143/5 TCZ, cast iron SE 2 HP, 143/5 TCZ, steel band E 2 HP, 143/5 TCZ, cast iron SF 3 HP, 143/5 TCZ, steel band F 3 HP, 143/5 TCZ, cast iron SG 3 HP, 182/4 TYZ, steel band G 3 HP, 182/4 TYZ, cast iron SH 5 HP, 182/4 TYZ, steel band H 5 HP, 182/4 TYZ, cast iron SJ 7.5 HP, 182/4 TYZ, steel band SK 10 HP, 182/4 TYZ, steel band *115/230 VC, 1PH, 60 Hz Only NOTE 1: complete pump model number must be placed after the dash which follows the motor code. NOTE 2: Pumps can be any configuration that corresponds to the pump mounting called out in the motor code. NOTE 3: For pump information, refer to Hydraulic Pump Catalog /US. Standard motors available from stock 91
Fluid Cooling P-BAR b Industrial BOL Series
Fluid Cooling P-BAR b Industrial BOL Series 10 BRAZED ALUMINUM CONSTRUCTION Performance Notes Bar and plate brazed aluminum core Provides the best heat transfer per given envelope size while minimizing
More informationProduct Information Packet EM2334T 20HP,1770RPM,3PH,60HZ,256T,0960M,TEFC,F1
Product Information Packet EM2334T 20HP,1770RPM,3PH,60HZ,256T,0960M,TEFC,F1 Copyright ll product information within this document is subject to Motors and Mechanical Inc. copyright protection, unless otherwise
More informationContactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business
More informationAgency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines
More informationSmall & Medium AC Accessories and Kits
Motor Bases, dapter These adapters permit mounting of new NEM frames so that shaft extension ends are positioned interchangeably with the old line NEM frames they replace. ll adapter mountings are supplied
More informationPart-Turn Electric Multi-Turn Electric
Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationSeries CDP2 Definite Purpose Contactors
Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications
More informationSeries CDP2 Definite Purpose Contactors
Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air
More informationPage 1 of 7 Attachment to IECEx TUN Issue 0
Page 1 of 7 The electric motor vibrator is used in order to facilitate the flowing of dust materials trough silos andor similar applications. It can be also used for other applications were separation
More informationMagnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:
Operation is similar to standard centrifugal pumps, except the impeller is driven with a magnetic coupling, eliminating the need for a shaft seal. Magnetic drive pumps must be used where flooded suction
More information2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors
00/00/400/600 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 180 200 kw 144 160 kva 200 218.8 kw 160 175 Ratings at 0.8 power factor. Please refer to the output
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationDC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.
HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with
More informationAgilent High Capacity RV Pumps & Roots Pumping Systems
Agilent High Capacity RV Pumps & Roots Pumping Systems 2-3 MS-Series Rotary Vane Pumps 4-5 RPS-Series Roots Pumping Systems and RPK-Series Roots Pumping Kits 6-7 Typical Applications 8-15 Pump Models MS-Series
More informationAC1036. Definite Purpose Contactors
Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous
More informationSeries: BPV, BPLHS. Vertical Multi-Stage Family Curve, 3500 RPM - 60Hz. Family Curves. Vertical Multi-Stage Pumps.
Series:, BPLHS Family Curves Vertical Multi-Stage Family Curve, 3500 RPM - 60Hz. 1 5/11 Series: General Information The Burks Series is made up of pumps with all wetted parts made of stainless steel. For
More informationData sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)
Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Pump curves Wilo-Drain TP 50 E - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 26 m 3 /h Optimal delivery head H opt 5.0 m
More informationTWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments
Dual line system Designed to work all the day, every day in extreme condition and difficult environments CONTENTS Applications 3 Description 4 Operation 5 Benefits 6 TWIN pump 7 TWIN measures 8 TWIN-PUMP
More informationUltra Quiet Series Electric Air Handler
Residential & Light Commercial HVAC Ultra Quiet Series Electric Air Handler 1 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz The Fedders multi-position air handlers, when matched with our air conditioners
More informationSeries description: Wilo-Drain VC
Series description: Wilo-Drain VC 0H[m] 18 16 14 12 10 8 6 4 2 VC 32/10 Wilo-Drain VC 0 2 4 6 8 10 12 VC 40/20 Q[m³/h] Design Vertically-mounted drainage pump (pedestal pump with IE2 motor) Application
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- P220-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 200 220 kw 160 176 kva - - kw - - Ratings at 0.8 power factor. Please refer to the output ratings
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- P165-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 150 165 kw 120 132 kva 168.8 187.5 kw 135 150 Ratings at 0.8 power factor. Please refer to the
More informationP88-3. Output Ratings. Dimensions and Weights. Prime Rating
- P88-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 80 88 kw 64 70.4 kva 90 100 kw 72 80 Ratings at 0.8 power factor. Please refer to the output ratings
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 150 165 kw 120 132 kva kw Ratings at 0.8 power factor. Please refer to the output ratings technical
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- P150-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 135 150 kw 108 120 kva 150 165 kw 120 132 Ratings at 0.8 power factor. Please refer to the output
More informationMovable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability
Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide
More informationP65-5. Output Ratings. Dimensions and Weights. Prime Rating
- P65-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 60 65 kw 48 52 kva 68.8 75 kw 55 60 Ratings at 0.8 power factor. Please refer to the output ratings
More informationP550-3L. Output Ratings. Dimensions and Weights. Prime Rating
- P550-3L Optional LS Upgrade #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency 400V, 50 Hz 480V, 60 Hz Prime Standby kva 500 550 kw 400 440 kva kw Ratings at 0.8 power factor. Please refer to the
More informationSOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems
SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) Central Vacuum Supply Systems 172.02.02 Excerpt from the Product Section C02 Edition 2010 Contents General Product
More informationData sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)
Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V) Pump curves Wilo-Drain TP 65 E - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 15.0 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H
More informationBulletin IND05 INDUSTRACON
Bulletin IND05 INDUSTRACON Models: IND-OT, IND-WT, IND-AH Industrial Exhauster Introduction CERTIFIED RATINGS Fans PennBarry certifies that the Series 61 Fans shown herein are licensed to bear the AMCA
More informationPortable Filter Cart Type SPFC
STAUFF Mobile Filter Units Portable Filter Cart Type SPFC Product Description The STAUFF Portable Filter Cart (SPFC) is a very complete and practical unit capable of off-line filtration, filling or emptying
More informationP400-3L. Output Ratings. Dimensions and Weights. Prime Rating
- P400-3L Optional LS Upgrade #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency 400V, 50 Hz 480V, 60 Hz Prime Standby kva 350 400 kw 280 320 kva kw Ratings at 0.8 power factor. Please refer to the
More informationP Output Ratings. Dimensions and Weights. Prime Rating
#DEALER_LOGO P275-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 250 275 kw 200 220 kva kw Ratings at 0.8 power factor. Please refer to the
More informationData Sheet Definite Purpose Contactors Ex9CK Series
Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed
More informationRatings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.
- P2000/P2250E #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 2000 2250 kw 1600 1800 kva kw Ratings at 0.8 power factor. Please refer to the output ratings
More informationP1000P1/P1100E1 50Hz
- P1000P1/P1100E1 50Hz #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 1000 1100 kw 800 880 kva kw Ratings at 0.8 power factor. Please refer to the output
More informationP Output Ratings. Dimensions and Weights. Prime Rating
#DEALER_LOGO P660-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 600 660 kw 480 528 kva kw Ratings at 0.8 power factor. Please refer to the
More informationGP-500 SERIES - Low Voltage
M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to
More informationP800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating
#DEALER_LOGO P800P1/P900E1 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 800 900 kw 640 720 kva 844 938 kw 675.2 750.4 Ratings at 0.8 power
More informationP Output Ratings. Dimensions and Weights. Prime Rating
#DEALER_LOGO P400-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 350 400 kw 280 320 kva kw Ratings at 0.8 power factor. Please refer to the
More informationDOWNDRAFT SANDING TABLES
888-377-2454 276-656-1039 fax DOWNDRAFT SANDING TABLES DUSKITS offers a comprehensive line of downdraft sanding tables for industry, and table kits for smaller shops and individual craftsmen All of our
More informationP1350P1/P1500E1 50Hz
- P1350P1/P1500E1 50Hz #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 1350 1500 kw 1080 1200 kva kw Ratings at 0.8 power factor. Please refer to the
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationSureFire PDI Lubricator
SureFire PDI Lubricator Automatic, Oil & Fluid Grease General The SureFire PDI Lubricator is an automatic, robust and durable pump that can handle oil and soft greases. Its compact size is designed to
More informationFLUID COOLING Industrial BOL Series
FLUID COOLING Idustrial Series AIR COOLED brazed alumium Costructio Features bar ad Plate Brazed Alumium Core rugged, lightweight, ad compact provides the best heat trasfer per give evelope size while
More informationFor applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.
For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationSign Illuminating Ballasts
Sign Illuminating Ballasts A Complete Range Of Solutions From The Name You Trust Universal Lighting Technologies ( Universal ) is known throughout the sign business as a company that can set and meet today
More informationEVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow
...Simple Effective Inexpensive to operate Economical The Saudi Factory for Air Conditioning Units No air cooled condenser needed No chiller or cooling tower needed No major control center No refrigerant
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationT-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C
: Product Overview Keeps its cool during peak heat loads and hot weather A/C Indoor/Outdoor Air Conditioners Chapter Contents PRODUCT OVERVIEW T15 Model 800 BTU...43 Indoor/Outdoor Air Conditioners...42
More informationSIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions
DB411/415/422/ DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More informationSafety Codes Council Conference Banff C Panel Discussion
Safety Codes Council Conference Banff 2014 90 C Panel Discussion Tim Driscoll OBIEC Consulting Ltd. George Morlidge Fluor Canada Ltd. Scott Basinger Eaton Canada René Leduc Marex Canada Limited Perspectives
More informationSOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)
SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) 172.02.02 Excerpt from the Product Section C02 Edition March 2007 Contents General Product Range, Features and
More informationand Refrigeration Institute). CAQ7 Capacitor Switching Contactors
SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic
More informationand Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors
C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,
More informationScrew pump Series ALLFUEL AFT
Screw pump Series ALLFUEL AFT Utilization For pumping light and heavy fuel oil. Main field of application ALLFUEL Transfer (AFT) pumps are compact pump sets designed for closed circuit and transfer applications
More informationAF-300 E11 Adjustable Frequency Drive
AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed
More informationAccessories. Servo Motors. Servo Motors B-47. Accessories
Servo Motors Servo Motors Accessories Accessories Page Cables B-48 Flexible Couplings B-52 Control Module B-55 Data Setting Software B-55 Accessory Sets B-56 Battery B-56 Regeneration Units B-57 B-47 Accessories
More informationGear Pump Units For single-line centralized lubrication systems
1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationSeries: BPV, BPLHS Family Curves
Series: BPV, BPLHS Family Curves Vertical Multi-Stage Family Curve, 3500 RPM - 60Hz. 5 /1 Series: BPV General Information The Burks BPV Series is made up of pumps with all wetted parts made of stainless
More informationUnderstanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi
Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive nfi Practical Demonstration of VFD Motor Speed Directly Proportional to Frequency Motor RPM= (120*F)/P Powerflex- 4M 0.4 KW= 0.5 Hp
More informationT BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options
T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts Industry Standards UL/cUL Listed; Type 12, 3R,
More informationGENESIS Indoor Air Conditioners
Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners
More informationCENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)
CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA 91746 (626) 330-3182 Fax (626) 330-9406 www.centralblower.com CATALOG REF - 01 JULY, 2001 Series RE Scoop with Grease Trough Sealed to blower
More informationT BTU/Hr Watts
763.576.3200 Spec-00734 H763.422.2211 Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts
More informationParts List _2.1. Flygt /.190
Parts List 886747_2. Flygt 3069 3069.60/.90 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3
More information2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors
00, 00, 400, 600, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box 0 975 Cottonwood
More informationSM-1100/SM-1500/SM-1600 ROTARY ACTUATORS
SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1100, SM-1500 and SM-1600 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating
More informationINCH-POUND MIL-PRF-55629/21G 10 March 2010 SUPERSEDING MIL-PRF-55629/21F 21 September 2005 PERFORMANCE SPECIFICATION SHEET
PERFORMANCE SPECIFICATION SHEET INCH-POUND 0 March 200 SUPERSEDING MIL-PRF-629/2F 2 September 200 CIRCUIT BREAKERS, MAGNETIC, PANEL SEAL, TRIP-FREE, SERIES TRIP, DOUBLE POLE (0.2 TO 0 AMPERES) This specification
More informationBartels Micropumps. ( ) Rev. 2.8
EN Bartels Micropumps Micropumps transporting the tiniest amounts of gases or liquids can be considered the heart of microfluidics. In many sectors they have become indispensable. Dosing lubricants, feeding
More informationSplit System Air Conditioner
Residential & Light Commercial HVAC Split System Air Conditioner 1 R-410A, 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 2 to 5 tons
More informationT BTU/Hr Watts
T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R,
More informationPhotologic Reflective Object Sensor
OPB76, OPB76, OPB762, OPB763 (Series N and T) OPB77, OPB77, OPB772, OPB773 (Series NZ and TZ) Features: Choice of mounting configurations Choice of four output configurations. (.6 mm) PCBoard mount (N
More informationOil/air cooler. Table of contents. Features. Applications. RE 50112/05.13 Replaces: Type KOL and KOLP
Oil/air cooler RE 50112/05.13 Replaces: 01.12 1/24 Type KOL and KOLP Component series 2X aximum flow 400 l/min [105 GP] H7131 Table of contents Contents Page Features, applications 1 Description, symbols
More informationN BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners
Spec-00732 F Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt INDUSTRY STANDARDS N36 / BTU/Hr. / Watt N28 BTU/Hr. Watt UL/cUL
More informationCENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)
CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA 91746 (626) 330-3182 Fax (626) 330-9406 www.centralblower.com CATALOG REF-11 OCTOBER 2011 Series RE Scoop with Grease Trough Sealed to blower
More informationGENESIS Indoor Air Conditioners
PH FX ( Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 74 74 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners
More informationTHE ULTIMATE DRY CHOICE
SMALL DRY PUMPS THE ULTIMATE DRY CHOICE nxds Dry Scroll Pump 6 XDS Scroll Vacuum Pump 68 XDD Diaphragm Vacuum Pump 7 D-LAB Diaphragm Vacuum Pump 75 6. nxds DRY SCROLL PUMP THE ULTIMATE DRY CHOICE With
More informationECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor
Oil Service Units ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor Easy filling, cleaning and pumping over Unbeatable ergonomics, optimal handling
More informationPhone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h
Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h Horizontal Multistage Pumps 50 Hz Stainless Steel 3-9 m3/h Model Number Explanation Example: 3AMH2B-51 3 = m 3 /h AMH = Series 2 = # of Stages
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective
More informationM BTU/Hr Watts. Finish. Options
Spec-00607 CPH FX ( Protective Cooling Air Conditioners Indoor Air Conditioners M13 1000 BTU/Hr. 293 Watt M17 1800 BTU/Hr. 527 Watt Industry Standards Maintains U/cUL Type 12 rating when properly installed
More informationEncapsulated Distribution
Encapsulated Distribution Transformers Commercial & Industrial Single Phase and Three Phase HPS Fortress Commercial Encapsulated Transformers Applications & Features... 224 Single Phase Standard Specification...
More informationN43 N36 N28. Sealed Enclosure Cooling Air Conditioners
SPECTRACOOL NARROW INDOOR/OUTDOOR N43 N36 N28 11000 BTU/Hr. / BTU/Hr. BTU/Hr. 3223 Watt / Watt Watt INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE IP 56 Internal Loop
More informationChinook Gas Furnace Multi-Position High Efficiency Condensing Furnace
Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace 1 stage PSC CXX-1-D 1 stage ECM CXX-1-X 2 stage PSC CXX-2-D 2 stage ECM CXX-2-V Modulating CXX-M-V, CXX-M-S Modulating Compact CC15-M-V
More informationType D mechanical diaphragm
SR Series Type D mechanical diaphragm The right dosing choice SR Series Type D Mechanical Diaphragm Dosing Pumps SUPPORTING ELEMENTS OF OUR PRODUCTS Versatility Different diaphragm sizes are available
More informationApplications Keypad Backlighting LCD Backlighting Symbol Backlighting Front Panel Indicator
High Performance Surface Mount Flip Chip LEDs Technical Data HP SunPower Series HSMA-H67/H69/H77/ H79/R661/R761 HSMC-H67/H69/H77/ H79/R661/R761 HSML-H67/H69/H77/ H79/R661/R761 Features High Brightness
More informationAir Conditioners. CR Compact, Mid-Size and Full-Size Air Conditioners and Accessories
Spec-00301 EPH FX (763) 422-2600 422-2211 Thermal Management CR Compact, Mid-Size and Full-Size and Accessories Industry Standards Refer to tables for specific UL/cUL Type ratings these air conditioners
More informationDimensions and Weight Size 2.79 HEIGHT X 1.6 WIDTH X 1.19 DEPTH IN, HEIGHT X WIDTH X DEPTH MM
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FF30MC 30MIN SPR Wound TMR Intermatic Inc. Catalog Number Manufacturer Description Weight per unit Product Category FF30MC
More informationSeries 8800 Radial Tip Fans Design 8812
Bulletin 8800-2 October 1996 Series 8800 Radial Tip Fans Design 8812 Description Index Series 8800 Radial Tip Fans The Design 8812 Radial Tip fan is a reliable, highly efficient, heavy duty, rugged fan
More informationITS Series Illuminated Tact Switch
Features/enefits Vertical and right angle SMT models Vertical and right angle thru-hole models Multiple caps and legends Several colors and bi-color options RoHS compliant /compatible Typical pplications
More informationMVSI-TS. Technical features
Technical features Power supply Three-phase voltage from 48V to 690V, 50Hz or 60Hz; suitable for use with an inverter from 20Hz to the base frequency, with constant torque load profile. Polarity 4, 6 and
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationRoots * RAS-J Air & RGS-J Gas Blowers. GE Energy
GE Energy Roots * RAS-J Air & RGS-J Gas Blowers Wide range of performance for pressure and vacuum applications on air or gas service for both dry and wet (liquid injection) conditions. GE Energy s Roots
More informationThree Phase - General Purpose. THREE PHASE: 3 kva - 9 kva Epoxy Encapsulated Series 76 ISO-Shield
26 THREE PHASE: 3-9 Epoxy Encapsulated Series 76 ISO-Shield Features UL Listed, File E3210. CSA Certified, File LR 560. Electrostatic shield between primary and secondary windings provides cleaner output
More informationKüba compact DF. The space-saving helper in filling stations, gastronomy and the trade
The space-saving helper in filling stations, gastronomy and the trade The space-saving helper in the positive and negative range Straightforward mounting Integrated air baffle plate Extremely space-saving
More information