Circuit breakers BZM. Circuit breakers BZM

Size: px
Start display at page:

Download "Circuit breakers BZM. Circuit breakers BZM"

Transcription

1 Circuit breakers BZM Circuit breakers BZM

2 Optimum and efficient protection for every application Compact Simple Safe The new BZM Eaton is a synonym for innovation, product quality, reliability anddecades of experience in the electrical engineering industry. Our productscomply with the latest national and international standards and regulations. Our Circuit Breaker Division takes pride in expanding the range of circuit breakers by adding the new BZM series designed for the lower LV segment and featuring factoryset thermal and magnetic tripping values. With our new BZM series we offer compact circuit breakers and a wide range of accessories for your business applications in all kinds of trade and industry. Easy handling, enhanced capacities and proven quality in the attractive Eaton design are additional features of this product. With the BZM1 for up to 125 A and the BZM2 for up to 250 A and the BZM3 for up to 400A, Eaton now also completes its range of products in the segment of circuit breakers, allowing us to cover all kinds of applications and requirements. Protect your electrical system and cables with our new BZM! Circuit breakers BZM July 2012

3 Three advantages for your benefit Compact Unbeatable when it comes to saving space: In the range of circuit breakers, the BZM1, BZM2and BZM3 are among the slimmest in their class and can therefore use the valuabledistribution space most efficiently, regardless of whether they are used for energy subdistribution or as a protection for incoming power in residential or functional buildings. Simple Easy to handle: For a fast starting are thermal and magnetic tripping values already fixed. The BZM series is absolutely easy to handle and allows for quick installation when executing your jobs. Safe Eaton's switchgears have a worldwide reputation for being the benchmark in lowvoltage power distribution. Eaton's quality protects people and assets against shortcircuits and overload, with the BZM series being designed for the 16 to 400 A range in subdistribution. Standards In complying with the IEC/EN standards and pollution degree III (IEC/EN 60947) we not only ensure the material but also the immaterial values of the BZM circuit breaker series. And with our BZM series, we also show consideration for the environment as these circuit breakers conform to the RoHS directives and can be recycled to a large extent. And last but not least the stylish outfit of the BZM series in the distinctive Eaton design makes these products attractive not only from a technical but also from an aesthetic point of view. For more information please turn to page 21. (technical data page). Circuit breakers BZM July

4 Range overview BZM1 Terminal cover XKSA Clip plate XC35 Phase barriers XKP BZM1 Interlock device XKAV Undervoltage release XU Shunt trip release XA Auxiliary contact Extension shaft XV Door rotary handle XTVD Rotary handle XDV Circuit breakers BZM July 2012

5 BZM1 small is powerful Concentrated technology with a long lifespan The BZM1 provides protection with rated currents up to 125 A and 36 ka breaking capacity, despite its light weight and slim width of only 25 mm per pole. The star within the circuit breaker family, is available as a 1, 2, 3 or 4pole device. For a fast starting are thermal and magnetic tripping values already fixed by Eaton. And it has an extremely long lifespan of up to 10,000 mechanical operating cycles. In addition, thanks to its terminal cover, the BZM1 features an IP 10 degree of protection. BZM1 Multiple mounting options Upsidedown or horizontal? It is up to you how you wish to mount the BZM1. But regardless of the mounting position and the side you choose for the supply of power, it will always provide the full protective function. BZM1... BT Cable Fixing: Cable lug and box terminal The proven cable lug with M6 screws and the box terminaltechnology for quick and easy mounting (BZM BT): both are included in the standard range of products. Solutions made to measure Remote tripping, signalling the switching status or undervoltage releasing in case of security relevent applications all of this is easy to manage for the BZM1. Thanks to the comprehensive range of accessories, the BZM1 will not only be the perfect match for standard applications, but also the ideal solution for individual handling requirements. Upon request the BZM1 is also available with a rotary handle (for direct mounting or door coupling). Characteristics / Features Rated current: 16 A up to 125 A Breaking Capacity: 15, 18, 25, 36 ka Cable fixing: Cable lug M6 or Box Terminal (BZM BT) Available poles: 3pole, 4poles Rated Voltage: 400/415V, 50/60Hz 3Position lever: Off Trip ON Electrical Supply: Line or LoadSide Circuit breakers BZM July

6 Range overview BZM2 Terminal cover XKSA Phase barriers XKP BZM2 Undervoltage release XU Shunt trip release XA Auxiliary contact Interlock device XKAV Circuit breakers BZM July 2012

7 BZM2 excellent protection for highrated current requirements Technology brought to the point Eaton's new BZM2 keeps a watchful eye on rated currents ranging from 125 to 250 A and a breaking capacity of 36 ka: it impresses especially with its functionality and robust design. The 3pole version (size W x D x H: 105 x 91.5 x 165 mm) with a lifespan of 8,000 mechanical operating cycles makes it a powerful protective device in a compact format. BZM2 Perfect adjustment to any environment Standard position, horizontal or upsidedown: you can select the mounting position just as freely as the side for the incoming power supply. Conventional connection via cable lug In line with the common practice for this type of rated current, the connection is established through a cable lug and M8 screws. Accessories in Eaton style Upon request and in our usual manner, we provide clever accessories such as auxiliary contacts, shunt trip releases, undervoltage releases or terminal covers. The BZM2 is a specialist in the higher range of rated current and offers everything you could want in terms of reliability, easy handling and compact design! Characteristics / Features Rated current: 125 A up to 250 A Breaking Capacity: 25, 36 ka Cable fixing: Cable lug M8 Available poles: 3pole Rated Voltage: 400/415V, 50/60Hz 3Position lever: Off Trip ON Electrical Supply: Line or LoadSide Circuit breakers BZM July

8 Range overview BZM3 Terminal cover XKSA Tunnel terminal XKA2 Phase barriers XKP Spreader XKV70KB Tunnel terminal XKA1 Rear connection XKR Undervoltage release XU Shunt trip release XA Auxiliary contact M22 BZM Circuit breakers BZM July 2012

9 BZM3 the perfect high current solution Strong ratings combined with compact dimensions The new BZM3 products are the most powerful Circuit Breaker within Eaton's BZM product range. The rated currentis ranging from 250 up to 400 Aand a maximumbreaking capacity of 50kA / 415VAC and 36kA /440VAC. Eaton's BZM3 products the prefect solution for your highamp applications with a compact size (size W x D x H: 140x 149 x 255 mm) BZM3 Simple to use As commonly known from the BZM1 and BZM2 product range, freely place the product Standard position, horizontal or upsidedown. Also the feeding direction can be chosen as required. Cable fixing:it`s simple! Wether you choose the standard cable lug version withm10 screw or the Tunnel Terminal optionas accessory the connection of your cable or busbar is quick and simple! The BZM3 not just Breaker! Accessories are very important for the different applications. Therefore also the BZM3 has the perfect accessories range available for you! Not only shunt trip releases, undervoltage releases and auxiliary contacts are part of the accessories range. Also terminal covers, spreaders, tunnel terminals and phase barriers and a rear connection kit is available for this new product range Characteristics / Features Rated current: 250 up to 400A Breaking capacity 25, 36 or 50kA / 415VAC Cable fixing: Cable lug M10 or Tunnel terminal (accessory) Rated voltage: 440V, 50/60Hz 3Position lever: Off Trip On Electrical Supply: Line or LoadSide Circuit breakers BZM July

10 Content Circuit breakers BZM Basic devices BZM BZM BZM Accessories BZM1 Auxiliary contacts Phase barrier Undervoltage release Shunt trip release Terminal cover Rotary handle Door rotary handle Extension shaft Dinrailadapter Cable lug Accessories BZM2 Auxiliary contacts Phase barrier Undervoltage release Shunt trip release Terminal cover Accessories BZM3 Auxiliary contacts Phase barrier Undervoltage release Shunt trip release Terminal cover Rear connection Spreaders Tunnel Terminal Cable lug Technical data BZM1, BZM2, BZM Mounting holes BZM1, BZM2, BZM Dimensions BZM1, BZM2, BZM Circuit breakers BZM July 2012

11 BZM types key BZM D 1 4 A 16 BT BZM Building circuit breaker Breaking capacity D 15kA E 18kA B 25kA C 36kA N 50kA Frame size 1, 2, 3 Number of poles 1 1 pole 2 2 pole 3 pole 4 4 pole Rated current A Cable fixing Cable lug terminal BT Box terminal Circuit breakers BZM July

12 Circuit breakers BZM1 1pole Protection of systems and cables Rated current Short circuit Economy switching capacity = rated releases 18kA at 240 V 50/60 Hz uninterrupted current I I n = I u A A 1 of each Cable lug terminal Box terminal Note: 1 piece phase barrier BZM1XKP included in delivery BZME11A BZME11A BZME11A BZME11A BZME11A BZME11A BZME11A BZME11A BZME11A BZME11A16BT BZME11A20BT BZME11A25BT BZME11A32BT BZME11A40BT BZME11A50BT BZME11A63BT BZME11A80BT BZME11A100BT Circuit breakers BZM July 2012

13 Circuit breakers BZM1 2pole Protection of systems and cables Rated current Short circuit Domestic switching capacity Economy switching capacity Basic switching capacity = rated releases 15kA at 415 V 50/60 Hz 18kA at 415 V 50/60 Hz 25kA at 415 V 50/60 Hz uninterrupted current I I n = I u A A 1 of each 1 of each 1 of each Cable lug terminal Box terminal BZMD12A BZMD12A BZMD12A BZMD12A BZMD12A BZMD12A BZMD12A BZMD12A BZMD12A20BT BZMD12A25BT BZMD12A32BT BZMD12A40BT BZMD12A50BT BZMD12A63BT BZMD12A80BT BZMD12A100BT Note: 1 piece phase barrier BZM1XKP included in delivery BZME12A BZME12A BZME12A BZME12A BZME12A BZME12A BZME12A BZME12A BZME12A20BT BZME12A25BT BZME12A32BT BZME12A40BT BZME12A50BT BZME12A63BT BZME12A80BT BZME12A100BT BZMB12A BZMB12A BZMB12A BZMB12A BZMB12A BZMB12A BZMB12A BZMB12A BZMB12A20BT BZMB12A25BT BZMB12A32BT BZMB12A40BT BZMB12A50BT BZMB12A63BT BZMB12A80BT BZMB12A100BT Circuit breakers BZM July

14 Circuit breakers BZM1 3pole Protection of systems and cables Rated current Short circuit Domestic switching Economy switching Basic switching Comfort switching = rated releases capacity 15kA capacity 18kA capacity 25kA capacity 36kA uninterrupted at 415 V 50/60 Hz at 415 V 50/60 Hz at 415 V 50/60 Hz at 400 V 50/60 Hz current I I n = I u A A 1 of each 1 of each 1 of each 1 of each Cable lug terminal Box terminal BZMD1A16 BZME1A16 BZMB1A BZMD1A20 BZME1A20 BZMB1A BZMD1A25 BZME1A25 BZMB1A BZMD1A32 BZME1A32 BZMB1A32 BZMC1A BZMD1A40 BZME1A40 BZMB1A40 BZMC1A BZMD1A50 BZME1A50 BZMB1A50 BZMC1A BZMD1A63 BZME1A63 BZMB1A63 BZMC1A BZMD1A80 BZME1A80 BZMB1A80 BZMC1A BZMD1A100 BZME1A100 BZMB1A100 BZMC1A BZMD1A125 BZME1A BZMD1A16BT BZME1A16BT BZMB1A16BT BZMD1A20BT BZME1A20BT BZMB1A20BT BZMD1A25BT BZME1A25BT BZMB1A25BT BZMD1A32BT BZME1A32BT BZMB1A32BT BZMC1A32BT BZMD1A40BT BZME1A40BT BZMB1A40BT BZMC1A40BT BZMD1A50BT BZME1A50BT BZMB1A50BT BZMC1A50BT BZMD1A63BT BZME1A63BT BZMB1A63BT BZMC1A63BT BZMD1A80BT BZME1A80BT BZMB1A80BT BZMC1A80BT BZMD1A100BT BZME1A100BT BZMB1A100BT BZMC1A100BT BZMD1A125BT BZME1A125BT Note: 2 pieces phase barriers BZM1XKP included in delivery 14 Circuit breakers BZM July 2012

15 Circuit breakers BZM1 Cable lug terminal Box terminal 4pole Protection of systems and cables Rated current Short circuit Domestic switching Economy switching Basic switching = rated releases capacity 15kA capacity 18kA capacity 25kA uninterrupted at 415 V 50/60 Hz at 415 V 50/60 Hz at 415 V 50/60 Hz current I I n = I u A A 1 of each 1 of each 1 of each BZMD14A16 BZME14A16 BZMB14A BZMD14A20 BZME14A20 BZMB14A BZMD14A25 BZME14A25 BZMB14A BZMD14A32 BZME14A32 BZMB14A BZMD14A40 BZME14A40 BZMB14A BZMD14A50 BZME14A50 BZMB14A BZMD14A63 BZME14A63 BZMB14A BZMD14A80 BZME14A80 BZMB14A BZMD14A100 BZME14A100 BZMB14A BZMD14A16BT BZME14A16BT BZMB14A16BT BZMD14A20BT BZME14A20BT BZMB14A20BT BZMD14A25BT BZME14A25BT BZMB14A25BT BZMD14A32BT BZME14A32BT BZMB14A32BT BZMD14A40BT BZME14A40BT BZMB14A40BT BZMD14A50BT BZME14A50BT BZMB14A50BT BZMD14A63BT BZME14A63BT BZMB14A63BT BZMD14A80BT BZME14A80BT BZMB14A80BT BZMD14A100BT BZME14A100BT BZMB14A100BT Note: 3 pieces phase barriers BZM1XKP included in delivery Circuit breakers BZM July

16 Circuit breakers BZM2 Cable lug terminal 3pole Protection of systems and cables Rated current Short circuit Basic switching Comfort switching = rated releases capacity 25kA capacity 36kA uninterrupted at 415 V 50/60 Hz at 415 V 50/60 Hz current / I n = I u A A 1 of each 1 of each BZMB2A125 BZMC2A BZMB2A160 BZMC2A BZMB2A200 BZMC2A BZMB2A250 BZMC2A Cable lug terminal (without overload release) BZMB2S Note: 2 pieces phase barriers BZM2XKP included in delivery 16 Circuit breakers BZM July 2012

17 Circuit breakers BZM3 Cable lug terminal 3pole Protection of systems and cables Rated current Short circuit Basic switching Comfort switching Normal switching = rated releases capacity 25kA capacity 36kA capacity 50kA uninterrupted at 415 V 50/60 Hz at 415 V 50/60 Hz at 415 V 50/60 Hz current I I n = I u A A 1 of each 1 of each 1 of each BZMB3A BZMB3A BZMB3A BZMB3A Note: 2 pieces phase barriers BZM3XKP included in delivery BZMC3A BZMC3A BZMC3A BZMC3A BZMN3A BZMN3A BZMN3A BZMN3A Circuit breakers BZM July

18 Accessories BZM1 Auxiliary contacts (only for 2, 3 and 4pole) 1 NO M22K NC M22K Door rotary handle (only for 2, 3 and 4pole) BZM1XTVD Phase barrier BZM1XKP Undervoltage release (only 3 and 4pole) VAC BZM1XU230240VAC VAC BZM1XU400415VAC VDC BZM1XU24VDC Shunt trip release (only 3 and 4pole) VAC BZM1XA230240VAC VAC BZM1XA400415VAC VDC BZM1XA24VDC Terminal cover (only for 1pole BZM) for 1pole BZM BZM11XKSA for 2pole BZM BZM12XKSA for 3pole BZM BZM1XKSA for 4pole BZM BZM14XKSA Extension axle (only for XTVD) Length 400 mm BZM1XV Length 600 mm BZM1XV DINrailadapter For 2pole BZM BZM12XC For 3 a.4pole BZM BZM1XC Cable Lug 35 mm 2 / M6 BZM1XKS mm 2 / M6 BZM1XKS BZM1 Locking Device BZM1XKAV Rotary handle (only for 2, 3 and 4pole) BZM1XDV Circuit breakers BZM July 2012

19 Accessories BZM2 Auxiliary contacts 1 NO M22K NC M22K Phase barrier BZM2XKP Undervoltage release VAC BZM13XU230240VAC VAC BZM13XU400415VAC VDC BZM13XU24VDC Shunt trip release VAC BZM13XA230240VAC VAC BZM13XA400440VAC VDC BZM13XA24VDC Terminal cover BZM2XKSA Interlock Device BZM2XKAV Circuit breakers BZM July

20 Accessories BZM3 Auxiliary contacts 1 NO M22K NC M22K Tunnel terminal (for one side of the breaker) 185 mm mm 2 BZM3XKA BZM1XKA Phase barrier Undervoltage release BZM3XKP VAC BZM13XU230240VAC VAC BZM13XU400415VAC VDC BZM13XU24VDC Cable lug 185 mm 2 NZM3XKS mm 2 NZM3XKS Shunt trip release VAC BZM13XA230240VAC VAC BZM13XA400440VAC VDC BZM13XA24VDC Terminal cover BZM3XKSA Rear connection BZM3XKR Spreaders (for one side of the breaker) BZM3XKV70KB Circuit breakers BZM July 2012

21 Technical data BZM1, BZM2 Mechanical specifications Rated current max.125 A BZM1 Rated current max.250 A BZM2 Standards IEC/EN IEC/EN Number of poles 1, 2, 3, 4 3 Device width mm 1pole:25, 2pole: 50, 3pole: 75, 4pole: 100 3pole: 105 Frame size mm Socket size mm Device depth mm ,5 Terminals Lift terminal, ring tongue connector Ring tongue connector Terminal capacity lift terminalmm rigid (solid/stranded) and flexible wire (2.5 50) Terminal capacity ring tongue 2 mm Diameter: max. 15 Diameter: max. 24 Busbar thickness mm max. 8 Terminal screw M6 (Pozidriv PZ2) M8 Terminal torque Nm 4 14 Degree of Protection (DIN VDE 0470) Builtin behind panel IP40 Builtin behind panel IP40 Climatic conditions Ambient temperature acc. to IEC 682( C/90..95% RH) acc. to IEC 682( C/90..95%RH) Storage C Operation C Mounting Positions Vertical and 90 in all directions Vertical and 90 in all directions Protection System Enclosures Number of mechanical operating cycles Pollution degree Electrical specifications With insulating > surround: IP40 With insulating > pole 2,3 and 4pole Maximum LV h.b.c. fuse A gg/gl Rated operational voltage U e V AC 230/240, 50/60 Hz 400/415, 50/60 Hz 400/415, 50/60 Hz Rated current I n A 16 up to up to , 160, 200, 250 Rated impulse withstand voltage U imp V (1.2/50 sec) (1.2/50 sec) (1.2/50 sec) Overvoltage category III III III Rated insulation voltage U i V For use in IT electrical power networks V 230/ / /415 Direction of incoming supply As required As required As required Number of electrical operating cycles Tripping characteristic > > Conventional nontripping current Int = 1.05 I n I nt = 1.05 I n I nt = 1.05 I 1) n Conventional tripping current It = 1.30 I n I t = 1.30 I n I t = 1.30 I n Reference temperature Notes: 1) not valid for BZMB2S250 C surround: IP40 Circuit breakers BZM July

22 Technical data BZM3 Mechanical specifications Standards Number of poles Device width Frame size Socket size Device depth Terminals Terminal capacity ring tongue mm mm mm mm Rated current BZM3 IEC/EN pole: max. 400 A Terminal capacity Tunnel Terminal XKA1 mm² max. 350A Copper Cabel/Aluminium cable: 1 x Terminal capacity Tunnel Terminal XKA2 mm² max. 400A Copper Cable/Aluminium cable: 1 x or 2 x Busbar thickness mm as required Terminal screw M10 Terminal torque Nm 30 Degree of Protection (DIN VDE 0470) Builtin behind panel IP40 Climatic conditions Ambient temperature acc. to IEC 682 ( C / % RH) Storage C Operation C Mounting positions Vertical and 90 in all directions Protection System Enclosures With insulating around: IP40 Number of mechanical operating cycles > Pollution degree 3 Electrical specifications Rated operational voltage U e V AC 440, 50/60 Hz Rated current In A 250, 320, 350, 400 Rated impulse withstand voltage U imp V (1.2/50 µsec) Overvoltage category III Rated insulation voltage U i V 690 For use in IT electrical power networks V 440 Direction of incoming supply As required Number of electrical operating cycles > Tripping characteristic Conventional nontripping current Int n Conventional tripping current It n Reference temperature C Circuit breakers BZM July 2012

23 Technical data BZM1, BZM2 Switching capacity BZMD1 BZME1 BZMB1 BZMC1 BZMB2 BZMC2 Rated shortcircuit breaking capacity I CU to IEC/EN operating sequence 0tCO, 130 V 50/60 Hz ICU ka tCO, 240 V 50/60 Hz ICU ka tCO, 400/415 V 50/60 Hz 1) I CU ka /400VAC I CS to IEC/EN operating sequence 0tCOtCO, 130 V 50/60 Hz ICS ka tCOtCO, 240 V 50/60 Hz ICS ka tCOtCO, 400/415 V 50/60 Hz 1) I CS ka /9*/400VAC Utilization category to IEC/EN *9kA/400VAC at IN=80, 100A Notes 1) for BZM1 1pole 230/400 V, 50/60Hz A A A A A A Letthrough energy BZM1 Letthrough current BZM1 Letthrough energy BZM2 Letthrough current BZM2 Circuit breakers BZM July

24 Technical data BZM3 Switching capacity BZMB3 BZMC3 BZMN3 Rated shortcircuit breaking capacity I cu to IEC/EN operating sequence 0tC0, 240 V 50/ 60 Hz Icu ka tCO, 400/415 V 50/60 Hz Icu ka tC0, 440 V 50/ 60 Hz I cs to IEC/EN operating sequence Icu ka tC0, 240 V 50/ 60 Hz Icu ka 25 42,5 50 0tCOtCO, 400/415 V 50/60 Hz Ics ka tC0, 440 V 50/ 60 Hz Icu ka 10 12,5 18 Utilization category to IEC/EN A A A Letthrough energy BZM3 Letthrough current BZM A 350A 320A 250A A 320A 350A 250A LetThroughEn ergy I²t [A²sec] LetThroughCurrent I It [A] Prospective ShortCircuit Current [A] Prospective ShortCircuit Current [A] Circuit breakers BZM July 2012

25 Technical data Between incoming circuitbreaker NZM (B)(C)(N)(H) and outgoing circuitbreaker BZM (D)(E)(B)(C) Incoming circuitbreaker NZM1 NZM2 I n up to 160A up to 250A I cu (415 V) 25k 36k 50k 100k 25k 36k 50k 100k Outgoing circuit breaker I cu (415 V) BZMD1 BZME1 BZMB1 BZMC1* BZME2 BZMB2 BZMC2 15 ka 18 ka 25 ka 36 ka* 18 ka 25 ka 36 ka up to 125 A up to 125 A up to 125 A up to 100 A* up to 250 A up to 250 A up to 250 A * * * * * * * * * I cu (400 V) Circuit breakers BZM July

26 DG Ver.104/11 DG Ver.104/11 Technical data Backup protection PLHT / BZM(B)(C)(D)(E)1 PLHTI n /1(2,3,4)/B(C)(D) n + BZMB1 + BZMB1 PLHTI n /1(2,3,4)/B(C)(D) n /1(2,3,4)/B(C)+ BZMC1 + BZMD1 I n [A] U e = 230/400 V, U e = 240/415 V 18 ka(bzmb1a125) 25 ka(bzmb1a16...a100) I n [A] U e = 230/400 V 25 ka PLHTI n /1(2,3,4)/B(C)(D) n + BZMD1 + BZME1 PLHTI n /1(2,3,4)/B(C)(D) n + BZME1 + BZME1 I n [A] U e = 230/400 V, U e = 240/415 V I n [A] U e = 230/400 V, U e = 240/415 V ka ka U e = 400/415V: I CU (BZMD1) = 15 ka (acc. to IEC/EN ) U e = 400/415V: I CU (BZME1) = 18 ka (acc. to IEC/EN ) U e = 400/415V: I CU (BZMB1) = 25 ka (acc. to IEC/EN ) U e = 400V: I CU (BZMC1) = 36 ka (acc. to IEC/EN ) U e = 240/415V: I CU (PLHT20..63/1..4/B,C,D) = 25 ka (acc. to IEC/EN ) U e = 240/415V: I CU (PLHT80/1..4/B,C,D, PLHT100/1..4/B,C) = 20 ka (acc. to IEC/EN ) U e = 240/415V: I CU (PLHT100/1..4/D, PLHT125/1..4/B,C) = 15 ka (acc. to IEC/EN ) Backup tests acc. to IEC/EN , App. A.6: U = 1.05*U e (O t CO) Backup protection PLHT / BZM(B)(C)2 PLHTI n /1(2,3,4)/B(C)(D) n + BZMB2 + BZMB2 PLHTI n /1(2,3,4)/B(C)(D) n + BZMC2 + BZMD2 I n [A] U e = 230/400 V, U e = 240/415 V 25 ka I n [A] U e = 230/400 V, U e = 240/415 V 25 ka U e = 400/415V: I CU (BZMD2) = 15 ka (acc. to IEC/EN ) U e = 400/415V: I CU (BZME2) = 18 ka (acc. to IEC/EN ) U e = 400/415V: I CU (BZMB2) = 25 ka (acc. to IEC/EN ) U e = 400/415V: I CU (BZMC2) = 36 ka (acc. to IEC/EN ) U e = 240/415V: I CU (PLHT20..63/1..4/B,C,D) = 25 ka (acc. to IEC/EN ) U e = 240/415V: I CU (PLHT80/1..4/B,C,D, PLHT100/1..4/B,C) = 20 ka (acc. to IEC/EN ) U e = 240/415V: I CU (PLHT100/1..4/D, PLHT125/1..4/B,C) = 15 ka (acc. to IEC/EN ) Backup tests acc. to IEC/EN , App. A.6: U = 1.05*U e (O t CO) 26 Circuit breakers BZM July 2012

27 DG Ver.207/11 Technical data Backup protection FAZ/PLSM / BZM(B)(C)(D)(E)1 FAZ/PLSMI n n /1(1N,2,3,3N,4)/B(C)(D) + BZMB1 FAZ/PLSMI U e = 230/400 V, U e = 240/415 V I n [A] Type B Type C Type D x x x ka(up to A100) 8 18 ka(up to A125) n /1(1N,2,3,3N,4)/B(C)(D) + BZMC1 I n [A] U e = 230/400 V Type B Type C Type D x ka x x FAZ/PLSMI n n /1(1N,2,3,3N,4)/B(C)(D) + BZMD1 FAZ/PLSMI n/1(1 N N,4)/B(C)(D) n /1(1N,2,3,3N,4)/B(C)(D) + BZME1 U e = 230/400 V, U e = 240/415 V U e = 230/400 V, U e = 240/415 V I n [A] Type B Type C Type D I n [A] Type B Type C Type D x x x x x x ka 6 18 ka U e = 400/415V: I CU ( BZMD1) = 15 ka (acc. to IEC/EN ) Ue = 240/415V: I CU (PLSM all types except D50, D63) = 15 ka (acc. to IEC/EN ) U e = 400/415V: I CU ( BZME1) = 18 ka (acc. to IEC/EN ) Ue = 240/415V: I CU (PLSM type D50, D63) = 10 ka (acc. to IEC/EN ) U e = 400/415V: I CU ( BZMB1) = 25 ka (acc. to IEC/EN ) Backup tests acc. to IEC/EN , App. A.6: U = 1.05* Ue (O t CO) U e = 400V: I CU (BZMC1) = 36 ka (acc. to IEC/EN ) Circuit breakers BZM July

28 Technical data Backup protection FAZ/PLSM / BZM(B)(C)2 FAZ/PLSMI n n/1(1n,2,3,3n,4)/b(c)(d) + BZMB2 FAZ/PLSMI n/1(1n,2,3,3n,4)/b(c)(d) + BZMC2 U e = 230/400 V, U e = 240/415 V U e = 230/400 V, U e = 240/415 V I n [A] Type B Type C Type D I n [A] Type B Type C Type D x x x x ka 6 20 ka ka x x 18 ka DG Vers. 1 05/11 U e = 400/415V: I CU (BZMB2) = 25 ka (acc. to IEC/EN ) U e = 400/415V: I CU (BZMC2) = 36 ka (acc. to IEC/EN ) U e = 240/415V: I CU (PLSM all types except D50, D63) = 15 ka (acc. to IEC/EN ) U e = 240/415V: I CU (PLSM type D50, D63) = 10 ka (acc. to IEC/EN ) Backup tests acc. to IEC/EN , App. A.6: U = 1.05*U e (O t CO) 28 Circuit breakers BZM July 2012

29 Tripping current curves BZM1 Tripping curve BZM1 16A, 3pole Tripping curve BZM1 20A, 3pole tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release 0.8 x nominal short current release 1.2 x nominal short current release t [sec] t [sec] Tripping curve BZM1 25A, 3pole Tripping curve BZM1 32A, 3pole tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release 0.8 x nominal short current release 1.2 x nominal short current release t [sec] t [sec] Circuit breakers BZM July

30 Tripping current curves BZM1 Tripping curve BZM1 40A,3pole Tripping curve BZM1 50A,3pole tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release 0.8 x nominal short current release 1.2 x nominal short current release t [sec] Tripping curve BZM 63A,3pole Tripping curve BZM1 80A,3pole tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release t [sec] t [sec] t [sec] tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release 30 Circuit breakers BZM July 2012

31 Tripping current curves BZM1, BZM2 Tripping curve BZM1 100A,3pole Tripping curve BZM2 125A tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release 0.8 x nominal short current release 1.2 x nominal short current release t [sec] Tripping curve BZM2 160A Tripping curve BZM2 200A tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release t [sec] t [sec] t [sec] tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release Circuit breakers BZM July

32 Tripping current curves BZM2 Mounting holes BZM1 Tripping curve BZM2 250A tripping characteristic acc,to IEC/EN conventional nontripping current Int= 1.05 In: t > 1h conventional tripping current It= 1.3 In: t > 1h 0.8 x nominal short current release 1.2 x nominal short current release t [sec] Mounting holes BZM1 32 Circuit breakers BZM July 2012

33 Mounting holes BZM1, BZM2, BZM3 Mounting holes BZM2 Mounting holes BZM3 All dimensions in mm Circuit breakers BZM July

34 Dimensions BZM1 Circuit breaker BZM1 1pole Circuit breaker BZM1 2pole 34 Circuit breakers BZM July 2012

35 Dimensions BZM1 Circuit breaker BZM1 3pole Circuit breaker BZM1 4pole Circuit breakers BZM July

36 Dimensions BZM2 and BZM3 Circuit breaker BZM2 3pole Circuit breaker BZM3 3pole 36 Circuit breakers BZM July 2012

37 Note Circuit breakers BZM July

38 Note 38 Circuit breakers BZM July 2012

39 Note Circuit breakers BZM July

40 Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit Electrical Sector Asia Pacific No.3, Lane 280, Linhong Road, Changning District, Shanghai Eaton Industries Pte Ltd Electrical Sector 4 Loyang Lane #0401/02 Singapore Eaton Corporation All Rights Reserved SEACA July 2012 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A) Circuit Breakers BZM Product Information Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A) BZM1 & BZM2 & BZM3 Accessories Optimum and Efficient Protection

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval

More information

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type

More information

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100 DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Circuit-breaker,3p,160A Partno. NZMN2-M160 CatalogNo. 265724 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63 Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC

More information

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100 Circuit-breaker,3p,400A Partno. LZMC3-A400-I Articleno. 111955 Similar to illustration Deliveryprogramme Product range Circuit-breaker Protective function System and cable protection Standard/Approval

More information

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles

More information

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories Circuit Breakers BZM Product Information Circuit Breaker BZM1 16 to 125 A Circuit Breaker BZM2 125 to 250A BZM1 & BZM2 Accessories Circuit breakers BZM1 3-pole Rated current Short circuit Basic switching

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology

More information

Type: DILM12 10(24VDC) Article No.:

Type: DILM12 10(24VDC) Article No.: Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM25 10(24V50HZ) Article No.: Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main. Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main. Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

GV2ME. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application Product datasheet Characteristics GV2ME32 TeSys GV2-Circuit breaker-thermal-magnetic - 24...32 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

TeSys circuit-breakers

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping

More information

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals Product datasheet Characteristics GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - spring terminals Main Range Product name Device short name Product or component type Device application

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

GV2P05. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application Product datasheet Characteristics GV2P05 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2P Circuit breaker Motor Thermal-magnetic

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

DMX and 4000 air circuit breakers from 800 to 4000 A

DMX and 4000 air circuit breakers from 800 to 4000 A DMX 3 20 and 00 air circuit breakers from 800 to 00 NEW 286 56 + 288 02 (p. 4) 286 4 + 288 02 (p. 4) 28 56 + 288 02 (p. 4) Dimensions (p. to 53) Electrical characteristics (p. 54 to 5) ir circuit breakers

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

GV2ME. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application Product datasheet Characteristics GV2ME10 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2ME Circuit breaker Motor Thermal-magnetic

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

Power Circuit of a UL508A Panel. Typical UL489 Application

Power Circuit of a UL508A Panel. Typical UL489 Application Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech

More information

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3 PowerPact Multistandard Catalogue numbers Functions and characteristics A-1 Installation recommendations B-1 Dimensions C-1 Wiring diagrams D-1 Additionals characteristics E-1 H-Frame, J-Frame unit-mount

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Manual Motor Protectors Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays....................

More information

A V 50Hz / V 60Hz

A V 50Hz / V 60Hz A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V

More information

Minicontactorrelay,2NO/2NC,DCoperated

Minicontactorrelay,2NO/2NC,DCoperated Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)

More information

Modular pulse operated latching relay 16 A

Modular pulse operated latching relay 16 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...

More information

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Features XT SC 012 B B A

Features XT SC 012 B B A Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

Data Sheet Definite Purpose Contactors Ex9CK Series

Data Sheet Definite Purpose Contactors Ex9CK Series Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed

More information

Features XT SC 012 B B A

Features XT SC 012 B B A Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.

More information

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

Manual Motor Starter Specifcations

Manual Motor Starter Specifcations Technical Data Manual Motor Starter Specifcations Bulletin 140A Topic Page Product Selection 2 Accessories 3 Specifications 6 Approximate Dimensions 13 Additional Resources These documents contain additional

More information

Accessories. EasyPact and Vigi CVS100/160/ short LV long LV Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242

Accessories. EasyPact and Vigi CVS100/160/ short LV long LV Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242 Catalogue numbers Accessories CVS100/160/250 DB112225 2 short LV429235 2 long LV429236 DB112226 Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242 LV429243 DB112225 DB112726 Aluminium connectors

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ /2 Introduction / 5SV RCCBs /10 5SM3 RCCBs /13 SIQUENCE 5SM3/5SU1 universal -sensitive RCCBs, type B and type B+ /18 Additional components /22 5SM2 RC units /30 5SU1 RCBOs /38 5SM6 AFD units /1 5SM6 AFD

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range

More information

3AH3 Vacuum Circuit-Breakers

3AH3 Vacuum Circuit-Breakers Catalog HG 11.03 Edition 2018 3AH3 Vacuum Circuit-Breakers Medium-Voltage Equipment siemens.com/3ah3 2 3AH3 Vacuum Circuit-Breakers Siemens HG 11.03 2018 R-HG11-373.tif Contents 3AH3 Vacuum Circuit-Breakers

More information

16 A and 25 A power contactors with or without handle

16 A and 25 A power contactors with or without handle 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 16 and 25 power contactors CONTENTS PGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning -

More information

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Busbar Systems. Altech UL489. UL489 Listed Busbars. Universal UL489 Busbar fits most UL489 Miniature Circuit Breakers in the market!

Busbar Systems. Altech UL489. UL489 Listed Busbars. Universal UL489 Busbar fits most UL489 Miniature Circuit Breakers in the market! Busbar Systems UL489 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Miniature Circuit Breakers (MCB). The advantages of this busbar system are: 30% Installation

More information

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

with additional normally-open signalling contact l With integrated AS interface Safety at Work. Safety Hinge Switch SHS3 In addition to the plug connection version, an SHS with fixed cable connection at the rear is also available Right and left hinged systems possible for optimum cable routing Mounting

More information

10 PDUs 19 PDUs Zero-U PDUs

10 PDUs 19 PDUs Zero-U PDUs 128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com 10 PDUs Page 1. GENERL CHRCTERISTICS...1 2. EQUIPMENT ND PERFORMNCE...3

More information

Gamma instabus. Technical product information

Gamma instabus. Technical product information Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output

More information

Selection guide siemens.com/sirius-modular-system

Selection guide siemens.com/sirius-modular-system SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement

More information

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286 CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have

More information

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori Podatkovni list proizvoda Karakteristike GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori Glavno Range Product name Device short name Product or component type Device application

More information

GR circuit breaker - hydraulic magnetic, Datasheet

GR circuit breaker - hydraulic magnetic, Datasheet GR circuit breaker - hydraulic magnetic, Datasheet railway, 35 mm rail Description Compact hydraulic magnetic circuit breaker for railway applications, to protect electronic equipment and components against

More information

MIKRO POWER FACTOR CORRECTION COMPONENTS

MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR REGULATOR Steps 6, 8, 12, 14 Voltage 1 4V AC Frequency 0 and 60 Hz Detection method Displacement Power Factor Input current A Modes Automatic,

More information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air

More information

llen-bradley 194R-HM4-NFPA3

llen-bradley 194R-HM4-NFPA3 Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES COMPANY INTRODUCTION Bridex Singapore Pte Ltd is founded in 1978 as a manufacturer of instruments transformer for the Asian market. We are the first local electrical switchgear

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

COMBINATION UNITS MARCH 2018

COMBINATION UNITS MARCH 2018 COMBINATION UNITS MARCH 2018 2 COMBINATION UNITS STATIONARY SOCKET OUTLET COMBINATIONS Variants 5 Dimensions 6 Wall-mounted Distributor Boxes (plastic) Series 45 8 Wall-mounted Distributor Boxes (plastic)

More information

MULTIS L72. Operating instructions

MULTIS L72. Operating instructions GB MULTIS L72 Operating instructions 2 SOCOMEC - Ref. : 876 091B ENGLISH GB Contents PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 5 PRESENTATION 4 INSTALLATION 5 Mechanical environment Climatic environment

More information

Electromechanical Relays

Electromechanical Relays Industrial Plugin Electromagnetic Relays Description Relays of general application - the new relays are distinguished by a modern design, high reliability and functionality. Modern technology ensures high

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The