VISION FLX2 MANUAL AUG 22,

Size: px
Start display at page:

Download "VISION FLX2 MANUAL AUG 22,"

Transcription

1 VISION FLX2 MANUAL AUG 22,

2 finding manual Step 1 Locate and mark the utility TRANSMITTER Step 2 CHECKING CABLE FOR VOLTAGE stake should be placed directly behind and in the opposite direction of the cable path. Connect the black end of the direct connection cables to the ground stake. Connect the red end of the direct connection cables on the cable to be checked. Power on. Press Frequency, and select FF. *FF is Find mode. Voltage is indicated. When voltage is greater than 25 volts, alarm sounds. 1

3 Step 3 CHECKING CABLE RESISTANCE This feature is used to determine the quality of the fault. Isolate both ends of the cable. stake should be placed directly behind and in the opposite direction of the cable path. Connect the black end of the direct connection cables to the ground stake. Connect the red end of the direct connection cables on the cable to be checked. Isolate both ends Power on. Press Frequency, and select FF. Press ADJUST. Resistance is indicated by the numerical value and the bar graph. Press ADJUST again or 30 sec. later, the display is returned to the FF. Step 4 FAULT FINDING After measurement of the resistance, fault finding power is adjusted automatically. 2

4 RECEIVER Connect the A-frame to the Receiver. A-frame Place both legs of the A-frame in the earth with the red leg pointing at the ground stake. Distance from ground stake should be approximately the same as the suspected depth of the cable. A-frame Same as depth of the cable Press and hold the Gain/Select key for one second, this will adjust the sensitivity of the Receiver and display 70.0% +/- If the Receiver displays OVER manually reduce the output on the until overload message is replaced with numbers. Note: This will be a reference number if line has multiple faults. Gain/Select. 3

5 Place the A-frame in the earth parallel along the path of the cable. The Receiver will display an arrow on the LCD. Arrow will point towards the red or blue indicator. The A-frame legs will be marked with a red or blue decal. Follow the direction the Receiver is showing (Example if the LCD is pointing towards the red indicator and the red leg of the A-frame is pointing towards the front walk forward.) Walk in this direction placing the A-frame in the earth every five to ten feet. Note: If LCD does not display arrow or signal strength A-frame is not reading signal. The A-frame may not be making contact with earth or signal is too weak due the distance from the fault point or cable path. Continue walking the cable path. When the A-frame begins to read signal the arrows and numbers will be displayed again. Pointed the Red indicator Red decal When the arrow changes directions the operator has passed the fault. Pointed the blue indicator Blue decal 4

6 Move backwards placing the A-frame in the earth every few inches when the arrow changes direction again you have reached the area of the fault. The fault point will be in the center of the A-frame. CONFIRM THE FAULT LOCATION Turn the A-frame 90 degrees perpendicular to the cable path. Place the A-frame in the earth and follow the direction the arrows are showing on the LCD. When the Arrows change direction you are over the fault. 5

7 To confirm the fault place the red leg over the suspected faulted area. Pivot the A-frame in a 360-degree circle if the indicator continually shows Red then fault is beneath the red leg. Multiple s Place both legs of the A-frame in the ground with the red leg directly over the fault point. With a line that has multiple faults, the fault that registers the highest reading on the display is the fault. That needs to be repaired. FAULT Low Resistance Earth High Resistance Earth 6

8 When doing the cable fault location work, the cable locating is possible. When being connected A-FRAME, the cable locating is possible with switching the mode to Cable locating mode. Press Peak/Null. finding mode Cable locating mode No bar-graph Yaw angle Real time depth The direction of the object line. Receiving level Operational frequency or Real time Current Move to the direction of the arrow and measure the location of the cable OUT OF RANGE Number of receiving level is blinked. Move in the direction of the arrow. Object line When going back to finding mode, press Peak/Null again. 7

Practice, Practice, Practice Using Prototek Digital Receivers

Practice, Practice, Practice Using Prototek Digital Receivers Practice, Practice, Practice Using Prototek Digital Receivers You have purchased some of the finest locating tools in the business, but they don t do magic. Your skill at handling these tools and recognizing

More information

Operating Instructions DCI-50-CT Cable Identifier

Operating Instructions DCI-50-CT Cable Identifier Operating Instructions DCI-50-CT Cable Identifier 1 CAUTION The equipment covered in these operating instructions should be used by qualified employees, trained in and familiar with the safety-related

More information

THE OPERATION OF A CATHODE RAY TUBE

THE OPERATION OF A CATHODE RAY TUBE THE OPERATION OF A CATHODE RAY TUBE OBJECT: To acquaint the student with the operation of a cathode ray tube, and to study the effect of varying potential differences on accelerated electrons. THEORY:

More information

Dynatel Advanced Cable Locator 2250

Dynatel Advanced Cable Locator 2250 3 Dynatel Advanced Cable Locator 2250 Quickly and Accurately Identify Underground Assets Pinpoint exact cable path and depth quickly and easily with this lightweight, easy-to-handle unit The 3M Dynatel

More information

CCL-S / CCT / CCL-P CUSTOM DESIGN RGB LCD DISPLAY BOARD PROGRAMMING AND INSTALLATION MANUAL VERSION: 1.2

CCL-S / CCT / CCL-P CUSTOM DESIGN RGB LCD DISPLAY BOARD PROGRAMMING AND INSTALLATION MANUAL VERSION: 1.2 -S / CCT / -P CUSTOM DESIGN RGB LCD DISPLAY BOARD PROGRAMMING AND INSTALLATION MANUAL VERSION: 1.2 AYBEY ELEKTRONIK GmbH Lothringer Allee 2 44805 Bochum Germany T: +49 (0) 234 687 36 82 9 G: +49 (0) 176

More information

THE OPERATION OF A CATHODE RAY TUBE

THE OPERATION OF A CATHODE RAY TUBE THE OPERATION OF A CATHODE RAY TUBE OBJECT: To acquaint the student with the operation of a cathode ray tube, and to study the effect of varying potential differences on accelerated electrons. THEORY:

More information

Operating Instructions DCI-50-CT Cable Identifier

Operating Instructions DCI-50-CT Cable Identifier Operating Instructions DCI-50-CT Cable Identifier 1 CAUTION The equipment covered in these operating instructions should be used by qualified employees, trained in and familiar with the safety-related

More information

NECESSITY IS THE MOTHER OF EXTECH S NEWEST CONTINUITY TESTER

NECESSITY IS THE MOTHER OF EXTECH S NEWEST CONTINUITY TESTER NECESSITY IS THE MOTHER OF EXTECH S NEWEST CONTINUITY TESTER Before recently, the problems presented by continuity testers available on the market were, to say the least, shocking. It s not that there

More information

Activity P32: Variation of Light Intensity (Light Sensor)

Activity P32: Variation of Light Intensity (Light Sensor) Activity P32: Variation of Light Intensity (Light Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Illuminance P32 Vary Light.DS P54 Light Bulb Intensity P54_BULB.SWS Equipment Needed

More information

Troubleshooting CS800/LC900 Bikes

Troubleshooting CS800/LC900 Bikes Troubleshooting CS800/LC900 Bikes CS800/900LC Bike Troubleshooting Entering the Maintenance Mode 15 Touch Screen: The Maintenance Mode is designed to help the tech determine certain faults in the upper

More information

2.4GHZ Digital Wireless Reversing Camera Kit

2.4GHZ Digital Wireless Reversing Camera Kit 2.4GHZ Digital Wireless Reversing Camera Kit I. Safety precautions for the product The receiving host is installed on the console of the car securely. Do not impact the LCD screen of the receiving host.

More information

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE CONTENTS : General Safety...... 3 Basic Properties.... 4 Front Panel Keys... 5 Back Panel Details 5 Charger Adapters.. 6 Utilization of Satfinder4......

More information

FBT-6. Relcom. Fieldbus. fieldbus powered USB. FOUNDATION Fieldbus. segment. Recording the. segment. The Monitor collects this transfer to.

FBT-6. Relcom. Fieldbus. fieldbus powered USB. FOUNDATION Fieldbus. segment. Recording the. segment. The Monitor collects this transfer to. Fieldbus Diagnostic Monitor Relcom FBT-6 fieldbus powered device add & drop indication shield short indication measures low, fieldbus and high frequency average and peak noise measures signal level for

More information

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster. Signal Booster Installation Guide Contents: AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster Before Getting Started.... 1 Antenna Options & Accessories.................... 1 Easy

More information

Directional Couplers and Splitters

Directional Couplers and Splitters Directional couplers and splitters divide trunk and feeder lines. 17-Amp current handling capacity. Excellent hum-modulation performance. 1/2-inch hard-line ports have extra length, creating a better seal

More information

BE3-GPR GENERATOR PROTECTIVE RELAY

BE3-GPR GENERATOR PROTECTIVE RELAY BE3-GPR GENERATOR PROTECTIVE RELAY Behind-the-Panel Mounting Semi-flush Mounting Basler Electric s BE3-GPR generator protective relay offers multiple protective features in a single package. Its microprocessor-based

More information

Lawnbott No Signal /Blackout Troubleshooting Guide

Lawnbott No Signal /Blackout Troubleshooting Guide The Lawnbott No Signal error can be the most difficult problem to resolve. There are two types of No Signal errors, persistent and intermittent. Persistent means the Lawnbott display shows No Signal as

More information

Manual. USP-mini. icroflown Technologies. Address: PO Box CE Arnhem The Netherlands Charting sound fields

Manual. USP-mini. icroflown Technologies. Address: PO Box CE Arnhem The Netherlands Charting sound fields icroflown Technologies Charting sound fields USP-mini Manual MFPA-V1.0 2014-11 Address: PO Box 2205 6802 CE Arnhem The Netherlands info@microflown.com Microflown Technologies Manual USP mini Page 2 of

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

1900/25 Vibration Monitor

1900/25 Vibration Monitor 1900/25 Vibration Monitor BENTLY NEVADA MADE IN USA VIBRATION MONITOR OK ALERT DANGER BYPASS DISPLAY MOD E RESET NORMAL ALERT ALERT ADJUST LEVEL DANGER DANGER LEVEL ADJUST BUFFER ED TRANSDUCER 1 IN/SEC

More information

Entry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano

Entry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano Entry Level Wind System Français Deutsch Nederlands Espagñol Italiano Entry Level Wind System Important Suitability: the Entry Level Wind System is only recommended for use on cruising boats up to 10.5m

More information

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters Signal Conditioners Highlights Battery powered Line powered Multi-purpose Modular-style Multi-channel Charge & impedance converters Industrial charge amplifiers & sensor simulators PCB Piezotronics, Inc.

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Lesson Sequence: S4A (Scratch for Arduino)

Lesson Sequence: S4A (Scratch for Arduino) Lesson Sequence: S4A (Scratch for Arduino) Rationale: STE(A)M education (STEM with the added Arts element) brings together strands of curriculum with a logical integration. The inclusion of CODING in STE(A)M

More information

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20 SPX-5600 Series Operations Manual Suprex Reader Extender - RF Wireless Interface SPX-5600MAN Page 1 of 20 SPX-5600 Series: Cypress Suprex SPX-5600 Series This manual covers the operation and setup of the

More information

OWL micro+ WIRELESS ELECTRICITY MONITOR

OWL micro+ WIRELESS ELECTRICITY MONITOR COS T NOW TARIFF 3A SENDER 30 25 20 15 10 5 0 SETTING UP YOUR OWL Index of pages 2. Setting up date and time 3. Tariff setting 4. To set up a single tariff 5. To set up a two tiered time tariff 6. To set

More information

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual TC3004 50Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication,

More information

IR REPEATER USER MANUAL

IR REPEATER USER MANUAL IR REPEATER USER MANUAL Location of Control LED USB TX Port RX Port Accessories Adaptor with USB Infra-Red Extender 1m x 3 2m x 3 Infra-Red Receiver 2 screws Important Safety Precautions - To prevent fire

More information

Digital output modules

Digital output modules Appendix 374 Digital output modules Order number Figure Type DO 8xDC 24V 2A DO 16xDC 24V 1A DO 16xDC 24V 2A DO 16xDC 24V 0.5A manual operation General information Note - - - - Features 8 outputs, in groups

More information

Sigma 1 - Axis Servo Motor and Cables - Troubleshooting Guide

Sigma 1 - Axis Servo Motor and Cables - Troubleshooting Guide LAST UPDATED: 12/21/2018 Introduction Press [POWER OFF]. Set the main circuit breaker to the OFF position. Wait until the high voltage LED on the vector drive is completely off before disconnecting any

More information

DSO138mini Troubleshooting Guide

DSO138mini Troubleshooting Guide DSO138mini Troubleshooting Guide Applicable main board: 109-13800-00I Applicable analog board: 109-13801-00H 1. Frequently Found Problems 1) LCD completely dark. No backlight 2) LCD lights up but no display

More information

FiberLink 7142 Series

FiberLink 7142 Series MANUAL FiberLink 7142 Series 4 Channels of Composite Video and 8 Channels of Audio over one single mode or multimode fiber Installation and Operations Manual WWW.ARTEL.COM FibeLink 7142 Series Contents

More information

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps

More information

2. Using LCD Digital Operator

2. Using LCD Digital Operator 2. Using LCD Digital Operator Functions of LCD digital operator JNEP-31(V) LCD digital operator has 2 modes: mode and mode. When the inverter is stopped, mode or mode can be selected by pressing the. In

More information

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview Dual Satellite Tracking Meter 38.8 With a built in Khz tone generator Specifications Power demand over 800 ma will result in an Over Current indication. Compatible With STARBAND Receivers Input Frequency:

More information

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADVANTAGES Helps avoid cascading capacitor failures. Sensing

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

3 Locating and Marking Products DOCUMENT OBSOLETE

3 Locating and Marking Products DOCUMENT OBSOLETE 3 Locating and Marking Products This was Wall Street, 1921 2 Imagine what it s like down there today. 3 Spotting the target with Dynatel Cable/Fault Locators. The opening photos in this brochure show the

More information

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators Know Your Oscilloscope Overview Front Panel Sharing Agilent s Resources with Engineering Educators www.educatorscorner.com Horizontal (time) controls Run control Special purpose menus/controls Trigger

More information

TC3005(LED/ELED/LASER) User's Manual

TC3005(LED/ELED/LASER) User's Manual 1. Description The gives users the ability to convert signals to format for data transmission (and vice-versa). These conversions can benefit users by extending transmission distances and/or enabling dissimilar

More information

VL35 QUICKSTART GUIDE. 3.5" 4K HDMI Field Monitor w/ Canon LP-E6 Battery Plate

VL35 QUICKSTART GUIDE. 3.5 4K HDMI Field Monitor w/ Canon LP-E6 Battery Plate VL35 QUICKSTART GUIDE 3.5" 4K Field Monitor w/ Canon LP-E6 Battery Plate What s Included 1 x VL35 Monitor 1 x AC Adapter 1 x Camera Shoe Mount 1 x Canon E6 Battery Plate 1 x AV Break Out Cable 1 x Screen

More information

C-net MULTI Operating Instructions MULTI. User s Guide

C-net MULTI Operating Instructions MULTI. User s Guide MULTI User s Guide -1- Introduction. Thank you for buying this C-net product. We wish you to enjoy your boating and intend that all C-net instruments enhance your pleasure. The instruments are designed

More information

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Description. Specifications and Ordering Information 1900/27 Vibration Monitor R Specifications and Ordering Information 1900/27 Vibration Monitor Description The 1900/27 is a single-channel, stand-alone, locally mounted vibration monitor. It can be used as a stand-alone machinery

More information

The Custom Interconnect Leader TM

The Custom Interconnect Leader TM LC Series.5.188.685 ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage: Insulation Resistance: VSWR: 50 ohms DC to 1.0 GHz 5,000 volts rms 3,000 volts rms 5,000

More information

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder

More information

Take Control of Quality Assurance

Take Control of Quality Assurance Take Control of Quality Assurance Underground Pipeline Coating A white paper from Element Integrity Group, Inc. Table of Contents Executive Summary... 2 The QC Burden of New Buried Pipelines... 3 Coating

More information

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

Manual of Operation for WaveNode Model WN-2m. Revision 1.0 Manual of Operation for WaveNode Model WN-2m. Revision 1.0 TABLE OF CONTENTS 1. Description of Operation 2. Features 3. Installation and Checkout 4. Graphical Menus 5. Information for Software Expansion

More information

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1 Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1 Contents 1) Grid-Tie Installation Block Diagram... 3 2) Installation Steps.... 4 2.1) Initial Setup.... 4 2.1.1)

More information

Fiber Optic GaAIAs LED OPF32_, OPF34_ Series OPF37_, OPF39_ Series OPF67_, OPF69_ Series

Fiber Optic GaAIAs LED OPF32_, OPF34_ Series OPF37_, OPF39_ Series OPF67_, OPF69_ Series I Features: High radiant output (OPF320, 340, 345, 370, 390, 395) Electrically isolated from case (OPF320, 340, 345, 370, 390, 395) Component premounted and ready to use (OPF322, 342, 347, 372, 392, 397)

More information

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide Introduction The EXA Series of Instruments (EXA PH200, PH400, PH202, PH402) provide much more than just a measurement. They are also

More information

GP-500 SERIES - Low Voltage

GP-500 SERIES - Low Voltage M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to

More information

Detect Color and Shape for various inspection

Detect Color and Shape for various inspection CVS2-RA SERIES MVS Series APPLICATI CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Wide range line-up CVS2-N20-RA Standard type CVS2-N10-RA Long range type CVS2-N0-RA Macro view type CVS2-N21-RA Narrow view

More information

Features. Applications

Features. Applications HSMM-C11/C12/C15/C17/C19 HSMN-C11/C12/C15/C17/C19/C191 SMT ChipLEDs Data Sheet Description These small chip-type LEDs utilize high efficient InGaN/SiC material to deliver competitively priced high performance

More information

EC456 Power System Protection Lab #1 Overcurrent Protection Relay

EC456 Power System Protection Lab #1 Overcurrent Protection Relay EC456 Power System Protection Lab #1 Overcurrent Protection Relay Learning Objectives: Understand the building blocks of a numerical protection relay Understand the HMI of the relay. Establish communication

More information

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense

More information

Aspect 2 Circuit Digital Scene Control

Aspect 2 Circuit Digital Scene Control Aspect 2 Circuit Digital Scene Control S p e c i f i c a t i o n 2 circuits of trailing edge dimming 500W total between the two circuits Both circuits feature independent overload, short-circuit and open-circuit

More information

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN ULTRA-TRAC APL A C O U S T I C P I P E L O C A T O R INSTRUCTION MANUAL Read and understand instructions before use. Patented MADE IN USA 851 Transport Drive Valparaiso, IN 46383-8432 Phone: 888 4SENSIT

More information

MOST. Getting the. BMW Assist. Climate. Settings

MOST. Getting the. BMW Assist. Climate. Settings feature BMW Assist Commun Getting the MOST Climate Any technological advance adds a level of complexity, and when it breaks we re the ones who are going to have to fix it. This includes the sophisticated

More information

MachineryMate 800 operating guide Handheld vibration meter

MachineryMate 800 operating guide Handheld vibration meter MachineryMate 800 operating guide Handheld vibration meter Wilcoxon Sensing Technologies 20511 Seneca Meadows Parkway, Germantown MD 20876, USA Amphenol (Maryland), Inc d/b/a Wilcoxon Sensing Technologies

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

TECHNICAL SUPPORT , or   FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD TECHNICAL SUPPORT 678-867-6717, or www.flightdisplay.com FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD FD151CV-LP 15.1" Low Profile LCD 2006 Flight Display Systems. All Rights Reserved.

More information

SNG-2150C User s Guide

SNG-2150C User s Guide SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120

More information

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 OWNER S MANUAL PW MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 ANY CHANGES OR MODIFICATIONS IN CONSTRUCTION OF THIS UNIT DEVICE WHICH IS NOT APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIACE COULD VOID

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For

More information

SC26 Magnetic Field Cancelling System

SC26 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields

More information

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR PART NUMBER: AOM150X03 SERIES DATE: SEPT 04, 2008 1. Introduction: 1.1 About the Product AOM150Xxx 15.0 Open Frame Monitor

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 40W 900mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 50,000

More information

Data Sheet. HSMx-C110/C170/C190/C191/C150 High Performance ChipLED

Data Sheet. HSMx-C110/C170/C190/C191/C150 High Performance ChipLED HSMx-C11/C17/C19/C191/C15 High Performance ChipLED Data Sheet HSMA-C11/C17/C19/C191/C15 HSML-C11/C17/C19/C191/C15 HSMC-C11/C17/C19/C191/C15 HSMZ-C11/C17/C19 Description These chip-type LEDs utilize Aluminum

More information

Preventing Fieldbus Physical Layer Problems

Preventing Fieldbus Physical Layer Problems Preventing Fieldbus Physical Layer Problems 1 Introduction Foundation Fieldbus is highly reliable when correctly installed and maintained. The key is in knowing what must be done to start with and to maintain

More information

Features. Applications R TOP VIEW

Features. Applications R TOP VIEW ASMT-CW InGaN White,.4mm Low Profile Right Angle Surface Mount ChipLED Data Sheet Description The ASMT-CW of white color chip-type LEDs is designed with the smallest footprint to achieve high density of

More information

Mission. Lab Project B

Mission. Lab Project B Mission You have been contracted to build a Launch Sequencer (LS) for the Space Shuttle. The purpose of the LS is to control the final sequence of events starting 15 seconds prior to launch. The LS must

More information

3mm Round White LED T-1. Technical Data Sheet. Part No: LL-304WC2E-W2-3TC

3mm Round White LED T-1. Technical Data Sheet. Part No: LL-304WC2E-W2-3TC 3mm Round White LED T-1 Technical Data Sheet Part No: LL-304WC2E-W2-3TC Spec No: UP302 Rev No:V.1 Date:Feb/16/2004 Page: 1 OF 8 Features Popular T-1 diameter package High efficiency Selected minimum intensities

More information

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 30,000 h For luminaires of protection class I and protection

More information

LDG FT-Meter For Yaesu FT-857 and FT-897 Version 1.1

LDG FT-Meter For Yaesu FT-857 and FT-897 Version 1.1 LDG FT-Meter For Yaesu FT-857 and FT-897 Version 1.1 LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series Driver LC 200W 1050mA UNV ADV IND ADVANCED series Product description Independent constant current LED Driver For dry, damp and wet locations Max. output power 200 W Up to 93.7 % efficiency For luminaires

More information

VersaCap Lighting System

VersaCap Lighting System VersaCap Lighting System Installation Instructions For Single Universe Lighting Systems Manual Version: V1.1 DFX 465 Taunton Avenue, Suite 108, West Berlin, NJ 08091 800-555-5280 www.dfxsoundvision.com

More information

PIPV200 QUAD System. User Manual

PIPV200 QUAD System. User Manual PIPV200 QUAD System User Manual System Features - Connects up to 4/8 Video Camera Adjustable Brightness, Contrast, Saturation, Hue and Sharpness - High Resolution 720X480 60Hz for NTSC 720X576 50Hz for

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 45W 1050mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 1,050 ma output power 45 W Nominal life-time up to 50,000

More information

RMS 8424S Quick Start

RMS 8424S Quick Start VIEWSIZE THE WORLD RMS 8424S Quick Start Standard 4 unit rack mount size 8 inch LCD 2 1024 3 (RGB) 600 16:9 / 4:3 adjustable SDI/HDMI embedded audio output via 3.5mm earphone socket Support SDI/DVI audio

More information

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4 Table of Contents Introduction... 1 Pin Description... 2 Absolute Maximum Rating... 3 Electrical Specifications... 4 Mechanical Specifications... 5 Thermal Specifications... 6 Over Temperature Protection...

More information

Features. Applications R TOP VIEW

Features. Applications R TOP VIEW ASMT-CB InGaN Blue,.4mm Low Profile Right Angle Surface Mount ChipLED Data Sheet Description The ASMT-CB of blue color chip-type LEDs is designed with the smallest footprint to achieve high density of

More information

TABLE OF CONTENTS. 2 SGM Light Technology 23/08/1999 Ver. 2.00

TABLE OF CONTENTS. 2 SGM Light Technology 23/08/1999 Ver. 2.00 Version 2.0 TABLE OF CONTENTS 2 SGM Light Technology 23/08/1999 Ver. 2.00 STUDIO SC USER GUIDE To Clear All the Memory...5 Manual Preset Section...6 The single or double preset:...7 To set the Single or

More information

N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012

N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012 N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012 Kit properly assembled and configured for Standard Serial LCD (LCD Not yet connected) Kit Components Item Qty Designator Part Color/Marking

More information

Manual. USP-regular. icroflown Technologies. Address: PO Box CE Arnhem The Netherlands Charting sound fields

Manual. USP-regular. icroflown Technologies. Address: PO Box CE Arnhem The Netherlands Charting sound fields icroflown Technologies Charting sound fields USP-regular Manual MFPA-V1.0 2014-11 Address: PO Box 2205 6802 CE Arnhem The Netherlands info@microflown.com Microflown Technologies Manual USP regular Page

More information

Bookcheck Model 966. Site Planning Guide

Bookcheck Model 966. Site Planning Guide Bookcheck Model 966 Site Planning Guide 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 Copyright 2002, 3M IPC. All rights reserved. www.3m.com/library 060-A 78-8123-7852-5,

More information

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS Low Profile Digital HDTV Over-the-Air Antenna w/built-in KING SureLock Digital TV Signal Meter Owner s Manual Roof Thickness: 1 to 4-1/2 Roof Thickness: 4-1/2 to 8 (when installed with KING extension #21850)

More information

Instruction Manual for Electronic Blowers and Flashboards

Instruction Manual for Electronic Blowers and Flashboards Instruction Manual for Electronic Blowers and Flashboards These instructions cover both the table model 17212 table top Electronic Bingo Blower (Fig 1) and the 17213 floor model Electronic Bingo Blower

More information

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages) Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section in

More information

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.andinst.com Instrument Model Number Instrument Serial Number MODEL RSP SANITARY

More information

SY-MS121 SY-MS121-AP

SY-MS121 SY-MS121-AP Installation Guide SY-MS121 and SY-MS121-AP Presentation Switcher with Multi-Format Inputs and Outputs 4 HDMI, 4 VGA, 1 Component video, 2 Composite video & 1 S-video inputs Simultaneous HDMI, VGA & HDBaseT

More information

A New Hardware Implementation of Manchester Line Decoder

A New Hardware Implementation of Manchester Line Decoder Vol:4, No:, 2010 A New Hardware Implementation of Manchester Line Decoder Ibrahim A. Khorwat and Nabil Naas International Science Index, Electronics and Communication Engineering Vol:4, No:, 2010 waset.org/publication/350

More information

Model PR710 Series Signal conditioner operating guide

Model PR710 Series Signal conditioner operating guide Model PR710 Series Signal conditioner operating guide Caution: This manual should be read carefully before operating any of the PR710 series signal conditioners. Wilcoxon Sensing Technologies 20511 Seneca

More information

PanelView 1400e CRT Maintenance

PanelView 1400e CRT Maintenance Release Note PanelView 1400e CRT Maintenance Maximizing the life of your PanelView 1400e, CRT Terminals To maximize the life of a CRT, the following is strongly recommended: Adjust the external brightness

More information

Data Sheet. HSMW-C120, HSMW-C130, HSMW-C191, HSMW-C197, HSMW-C265 White ChipLEDs. Description. Features. Applications

Data Sheet. HSMW-C120, HSMW-C130, HSMW-C191, HSMW-C197, HSMW-C265 White ChipLEDs. Description. Features. Applications HSMW-C12, HSMW-C13, HSMW-C191, HSMW-C197, HSMW-C265 White ChipLEDs Data Sheet Description These white ChipLEDs come in unique shades of white and provide product differentiation for backlighting application.

More information

Charlie Foxtrot Features include:

Charlie Foxtrot Features include: Charlie Foxtrot is a digital buffer/granular pedal with both autocapture and manual-capture of the input signal. Playback and capture can be manipulated through several parameters: The six knobs control

More information

Xanura Programmeer Unit Type PUX

Xanura Programmeer Unit Type PUX Xanura Programmeer Unit Type PUX Disclaimer 2 BEFORE YOU BEGIN READ ALL INSTRUCTIONS. CAUTION:This is a high voltage device. Use extreme caution around the power connections on this product. The PUX is

More information

Data Sheet. HSMx-C120, HSMx-C177, HSMx-C197 and HSMx-C265. High Performance Chip LEDs. Description. Features. Applications. Device Selection Guide

Data Sheet. HSMx-C120, HSMx-C177, HSMx-C197 and HSMx-C265. High Performance Chip LEDs. Description. Features. Applications. Device Selection Guide HSMx-C12, HSMx-C177, HSMx-C197 and HSMx-C265 High Performance Chip LEDs Data Sheet Description These chip type LEDs utilize Aluminium Indium Galium Phosphide (AlInGaP) material technology. The AlInGaP

More information

DTV744 Installation Quick Start Guide

DTV744 Installation Quick Start Guide DTV744 Installation Quick Start Guide The Wegener Model DTV744 8VSB 4-Channel Demodulator receives VHF/UHF broadcast HDTV 8VSB signals and provides output ASI streams for connection to an advanced cable

More information

The membership approved Carl Bulger s motion that we make no changes to the Constitution and By-Laws.

The membership approved Carl Bulger s motion that we make no changes to the Constitution and By-Laws. Carl Bulger presided. The membership approved Carl Bulger s motion that we make no changes to the Constitution and By-Laws. Bob Blum has been working long and hard on the old computers in the Computer

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 8000 Vdc 4 Proportional Output Voltage 4 Six-Sided Shielded Case 4 60 khz Switching Frequency 4 5000 Vdc Output Isolation 4 Continuous Short Circuit

More information