2. Using LCD Digital Operator
|
|
- Basil Sharp
- 5 years ago
- Views:
Transcription
1 2. Using LCD Digital Operator Functions of LCD digital operator JNEP-31(V) LCD digital operator has 2 modes: mode and mode. When the inverter is stopped, mode or mode can be selected by pressing the. In mode, the operation is enabled. Instead, in the mode, the parameter settings for operation can be changed but the operation is not enabled. The component names and function are shown as below: REMOTE SEQ REF DIGITAL OPERATOR JNEP-31(V) JOG operation mode indicators : lit when in mode : lit when there is a forward run command input : lit when there is a reverse run command input SEQ : lit when the run command is enabled from the control circuit terminal or RS-485 port (REMOTE mode) REF : lit when the frequency reference from the control circuit terminals (VIN or AIN) or RS-485 port is enabled (REMOTE mode) LCD Chinese : 2-line by 8-character English : 2-line by 20-character Keys (Key functions are defined in Table 7) Fig. 8 LCD Digital operator Remote/Local switch function: Local mode command input from LCD Digital Operator (SEQ off) Frequency command input from LCD Digital Operator (REF off) Remote mode command input from control circuit (when Sn-04=1) or RS-485 comm. port (when Sn-04=2) (SEQ lit) Frequency command input from control circuit (when Sn-05=1) or RS-485 comm. port (when Sn-05=2) (REF lit) 2-1
2 Table 7 Key's functions Key Name Function / operation status Switches over between program mode () and drive mode (). JOG JOG / INCREMENT DECREMENT / Enable jog operation from LCD digital operator in operation (). Select the rotation direction from LCD digital operator. Set the number of digital for user constant settings. Also It acts as the reset when a fault has occurred. Select the menu items, groups, functions, and user constant name, and increment set values. Select the menu items, groups, functions, and user constant name, and decrement set values. Select the menu items, groups, functions, and user constants name, and set values (). After finishing the above action, press the (). Start inverter operation in () mode when the digital operator is used. The will light. Stop inverter operation from LCD digital operator. The can be enabled or disabled by setting the parameter Sn-07 when operating from the control circuit terminal., indicator lights or blinks to indicate the 3 operating status: Inverter output frequency Frequency setting Blink OFF 2-2
3 contents in mode and mode Power on mode mode *1 An- monitor/set Bn- monitor/set Sn- monitor/set Cn- monitor/set Frequency reference value display monitor/set item Un- monitor An- monitor/set *2 Bn- monitor/set + Sn- monitor *3 Cn- monitor *1 When the inverter is powered up, the inverter system immediately enters into mode. Press the, the system will switch into mode. If the fault occurs, press the and enter into mode to monitor the corresponding Un- contents. If a fault occurs in the mode, the corresponding fault will be. Press the and reset the fault. *2 The monitored items will be according to the settings of Bn-12 and Bn-13. *3 When in the mode, press the and, the setting values of Sn- and Cn- will only be for monitoring but not for changing or setting. 2-3
4 Parameter description The inverter has 4 groups of user parameters: Parameters Description An- Frequency command Bn- Sn- Cn- Parameter groups can be changed during running System parameter groups (can be changes only after stop) Control parameter groups (can be changed only after stop) The parameter setting of Sn-03 (operation status) will determine if the setting value of different parameter groups are allowed to be changed or only to be monitored, as shown below: Sn-03 mode mode To be set To be monitored To be set To be monitored 0 *1 An,Bn Sn,Cn An,Bn,Sn,Cn - 1 An Bn,(Sn,Cn) *2 An Bn,Sn,Cn *1: Factory setting *2: When in mode, the parameter group Sn-, Cn- can only be monitored if the and the are to be pressed simultaneously. *3:After a few trial and adjustment, the setting value Sn-03 is set to be 1 so as not be modified again. 2-4
5 Example of using LCD digital operator Note: Before operation: Control parameter Cn-01 value must be set as the input AC voltage value. For example, Cn-01=380 if AC input voltage is 380. This example will explain the operating of the inverter according to the following time chart. OPERATI MODE (1) (2) (3) (4) (5) (6) (7) (8) 60 Hz POWER SET INPUT VOLTAGE JOG OPERATI FREQUENCY SETTING FREQ REF. VALUE CHANGED 60Hz Example of operation Description Key Sequence Digital Operator Remark (1) (2) When Power on Input voltage setting (e.g. AC input voltage is 380V ) (continued) Select frequency reference value Select mode Select CTROL PARAMETER Cn-01 setting Input Voltage 380V press 3 times Freq. Cmd Hz An -01 Freq. Cmd. 1 Cn -01- Input Voltage Cn-01 = 440.0V Input Voltage Cn-01 = 380.0V Input Voltage Entry Accepted OFF for 0.5 sec 2-5
6 (continued) Description Key Sequence Digital Operator Remark (3) JOG Select mode Select output frequency Freq. Cmd Hz Freq. Cmd.0.00 Hz O/P Freq Hz Select direction of rotation (When power on, initially defaulted ) (4) Frequency setting Jog operation Select frequency cmd JOG press 4 times O/P Freq Hz Freq. Cmd Hz Freq. Cmd Hz 15 Hz Change frequency cmd Freq. Cmd Hz Set new frequency cmd Freq. Cmd Hz Entry Accepted ed for 0.5sec Confirm the display. (5) run Select O/P frequency Running operation O/P Freq Hz Freq. Cmd Hz O/P Freq Hz Freq. Cmd Hz (6) Frequency command change 60 Hz Select frequency cmd Change reference value press 4 times Freq. Cmd Hz Freq. Cmd Hz (7) Enter new frequency cmd setting Select frequency cmd Change to Freq. Cmd Hz Entry Accepted O/P Freq Hz O/P Freq Hz ed for 0.5sec Confirm the display. (8) Decrement to O/P Freq Hz (Blinking while decel.) 2-6
7 Example of display (use and s to display monitored items/contents) Description Key Sequence Digital Operator Remark Frequency Command Freq. Cmd Hz Moniter Contents *1 O/P Freq Hz Output Current O/P I 12.5 A Output Voltage DC Voltage Output Voltage Output Current O/P Volt V DC Volt V O/P Volt V O/P I 12.5 A *1 The monitor contents can be selected by the setting of Bn-12 and Bn
Understanding VFD. Variable Frequency Drive. nfi. nfi
Understanding VFD Variable Frequency Drive Practical Demonstration of VFD Delta- M Series 1.5 KW I/P: 230V 1/3 Phase O/P: 230 3 Phase VFD Status Screen Motor OFF Command Freq. Parameters Direction Amperes
More informationRYKO Italia s.r.l. V. Casale Morano Po (Al) t f
Italia RYKO Italia s.r.l. V. Casale 43-15025 Morano Po (Al) t.0142 494411 f. 85872 June 30, 2003 ITALIA SERVICE BULLETIN - # 4-013 VFD parameter settings for conveyor equipment with Mitsubishi PLC MACHINES
More informationUnderstanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi
Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive nfi Practical Demonstration of VFD Motor Speed Directly Proportional to Frequency Motor RPM= (120*F)/P Powerflex- 4M 0.4 KW= 0.5 Hp
More informationSynchro System PHOTO NOT AVAILABLE. Description. Applications. Features
Innovative Solutions in Engineering BBG-RSSS-90-400-1 Redundant Serial to Synchro System Description PHOTO NOT AVAILABLE Applications Radar Systems (antenna azimuth) Navigation Systems (gyrocompass, speedlog,
More informationFor applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.
For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!
More informationNoise Detector ND-1 Operating Manual
Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation
More informationSCT CAMERA CONTROL CODE TRANSLATOR AD MANCHESTER to PELCO RS-422 Ver. 1.51
SCT- CAMERA CONTROL CODE TRANSLATOR AD MANCHESTER to PELCO RS- Ver.. www.sennetech.net Sennetech, Inc. W. Bath Rd. Perry, MI U.S.A. Ph () -0 Fax () - SCT- Ver.. PRODUCT DESCRIPTION The SCT- is an American
More informationPart No. ENC-LAB01 Users Manual Introduction EncoderLAB
PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder
More informationCONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET
CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET 230 Volt Single Phase logic control panel for twin motors pair of swinging gates and single leaf swing gate Integral radio receiver,
More informationOTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL
OTM-4000 FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-000331 REV B www.olsontech.com
More informationELCOM. Part Application Instruction. Release (V S 0.5) YS Kim S Jeong. OS Program Change to V S1.5 YS Kim S Jeong
Page 1/23 Door System(S-type) Rev. No. 0 1 2 3 Revision History Date Aug. 2004 Jun 2006 Sep 2006 Oct 2008 Revision Contents Prepared by Checked by Release (V S 0.5) YS Kim S Jeong OS Program Change to
More informationMODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR
MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR USERS MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-000412 Rev. B www.olsontech.com
More informationMotion Control G7 Drive Software Technical Manual
Software Number: VSG13306X, Drive Models: CIMR-G7UXXXXX-117 Document Number: TM.G7SW.117, Date: 05/16/08, Rev: 08-05 Motion Control G7 Drive Software Technical Manual Contents: 1.0 Overview... 3 2.0 Changes
More informationCOMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416
COMPANY MX 9000 Process Monitor Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:MXMAN082416 1 Table of Contents Unpacking...3 Quick Guide...3 Connect to Sensor...3
More informationSPECIFICATION NO NOTE
NOTE The Model 207-1 is a special version of the standard M-207 Power Supply. It has been altered for a special applications requiring low current operation at high arc voltages in ambient and pressurized
More informationVideo Scaler Pro with RS-232
Video Scaler Pro with RS-232 - ID# 783 Operation Manual Introduction Features The Video Scaler Pro with RS-232 is designed to convert Composite S-Video and YCbCr signals to a variety of computer and HDTV
More informationModel 7600 HD/SD Embedder/ Disembedder Data Pack
Model 7600 HD/SD Embedder/ Disembedder Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0.1 This data pack provides detailed installation, configuration and operation information for the 7600 HD/SD
More informationBurlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix
v1.2 Burlington County College INSTRUCTION GUIDE for the Hewlett Packard FUNCTION GENERATOR Model #33120A and Tektronix OSCILLOSCOPE Model #MSO2004B Summer 2014 Pg. 2 Scope-Gen Handout_pgs1-8_v1.2_SU14.doc
More informationSPECIFICATION NO Model 207 Automatic GTAW Welding System
1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small
More informationCT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions
CT340 and CT641 High Performance Low Cost Controller for Rotating Cutters and Printing Rolls Precision controller for Rotating Cutters and Printing Rolls Easy parameter setting and immediately ready to
More informationFS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws
control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com FS340 and FS641 High Performance
More informationTRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015
TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V1.2-1.4 January 2015 A display and command module for the Trimble Thunderbolt GPS with 10MHz reference oscillator. by Hubbatech Software Revision Notes: 1.2-2014
More informationwith Simulated Outputs Description Applications Features
Innovative Solutions in Engineering Synchro to ACP/ARP Converter with Simulated Outputs Description The is a stand-alone system, which provides data format conversion of Synchro to ACP/ARP. The unit is
More informationADJUSTABLE SPEED DRIVES. nc1 Drive
ADJUSTABLE SPEED DRIVES nc1 Drive Ultra-Compact Sub-Micro Drive The nc1 is a sub-micro, or nano-sized drive with a full range of features to meet the needs of nearly any user. The nc1 is designed to be
More informationModel 6010 Four Channel 20-Bit Audio ADC Data Pack
Model 6010 Four Channel 20-Bit Audio ADC Data Pack Revision 3.1 SW v1.0.0 This data pack provides detailed installation, configuration and operation information for the Model 6010 Four Channel 20-bit Audio
More informationUser Manual SM-7070WR
User Manual SM-7070WR PRODUCT FUNCTION AND APPLICATION INTRODUCTION 1. Product function 7 inch digital panel Screen Ratio: 16: 9 Resolution: 800*RGB*480 Front Key Function: 7pcs mechanical keys Remote
More informationAurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1
Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1 Contents 1) Grid-Tie Installation Block Diagram... 3 2) Installation Steps.... 4 2.1) Initial Setup.... 4 2.1.1)
More informationModel 5240 Digital to Analog Key Converter Data Pack
Model 5240 Digital to Analog Key Converter Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0 This data pack provides detailed installation, configuration and operation information for the 5240 Digital
More informationFWD8000 Dante enabled four wire box
FWD8000 Dante enabled four wire box by CTP Systems Product warranty This unit is guaranteed for a period of one year from dispatch of the goods. This guarantee is a return to base warranty. In the unlikely
More informationInstallation and User Guide 458/CTR8 8-Channel Ballast Controller Module
Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach
More informationC O B A R 18R U s e r G u i d e P a g e 1. User Guide COBRA 18R. Wireless Firing System.
C O B A R 18R U s e r G u i d e P a g e 1 User Guide COBRA 18R Wireless Firing System C O B A R 18R U s e r G u i d e P a g e 2 TABLE OF CONTENTS 1. SYSTEM INTRO... 3 2. POWER ON... 4 3. REMOTE / FIRING
More informationModel 1476-C SuperQuad HR
Model 1476-C SuperQuad HR Installation and Operating Instructions Table of Contents Page Table of Content... 2 System Description... 3 Features... 3 Installation... 4 Internal Setups... 4 Connections...
More informationModel 5405 Dual Analog Sync Generator Data Pack
Model 5405 Dual Analog Sync Generator Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0 This data pack provides detailed installation, configuration and operation information for the 5405 Dual Analog
More informationAUTOPILOT DLM Satellite Downlink Manager USER GUIDE
AUTOPILOT DLM Satellite Downlink Manager USER GUIDE AUTOPILOT User Guide Rev 3.70 Nov. 2004. Broadcast Automation Systems, Inc. 35 Sunnypoint Crescent, Scarborough, ON, Canada M1M 1B8 tel: 416-264-8415
More informationSingle Axis Position Controller
SERIES P9511 Single Axis Position Controller Compact Construction Simple Go-to operation Integrated Relay Output Integrated Mains Power Supply ELEKTRO-TRADING sp. Z o.o. 44-109 Gliwice, ul. Mechaników
More informationTroubleshooting CS800/LC900 Bikes
Troubleshooting CS800/LC900 Bikes CS800/900LC Bike Troubleshooting Entering the Maintenance Mode 15 Touch Screen: The Maintenance Mode is designed to help the tech determine certain faults in the upper
More informationCCL-S / CCT / CCL-P CUSTOM DESIGN RGB LCD DISPLAY BOARD PROGRAMMING AND INSTALLATION MANUAL VERSION: 1.2
-S / CCT / -P CUSTOM DESIGN RGB LCD DISPLAY BOARD PROGRAMMING AND INSTALLATION MANUAL VERSION: 1.2 AYBEY ELEKTRONIK GmbH Lothringer Allee 2 44805 Bochum Germany T: +49 (0) 234 687 36 82 9 G: +49 (0) 176
More informationINSTRUCTION MANUAL BREAKER FAILURE RELAY GRC100
INSTRUCTION MANUAL BREAKER FAILURE RELAY GRC100 Toshiba Energy Systems & Solutions Corporation 2017 All Rights Reserved. ( Ver. 1.5) Safety Precautions Before using this product, please read this chapter
More informationBel 2120B. Analogue/AES/SDI Shuffler. User s Guide Version /05/04
Bel 2120B Analogue/AES/SDI Shuffler User s Guide Version 1.0 06/05/04 BEL (Digital Audio) Ltd. has made every effort to ensure the accuracy of information contained within this document which is nevertheless
More informationSC26 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields
More informationAPPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone
APPLICATION NOTE # Product: 930A Communications Test Set 930i Communications Test Set Monitoring DTMF Digits Transmitted by a Phone Introduction This Application Note describes how to configure and connect
More informationDigital Ratio Controller
Digital Ratio Controller RSC-406 Control Panel USER S MANUAL RATIO CONTROLLER SPEED RUN PRG ERR RATIO % CH RSC-406 Prelude Thank you for applying our RSC-406 Ratio Controller (abb.406) to you machinery
More informationHardware & software Specifications
Hardware & software Specifications Réf : PRELIMINARY JUNE 2007 Page 2 of 17 1. PRODUCT OVERVIEW...3 2. TERMINOLOGY...4 A. THE FRONT PANEL...4 B. THE REAR PANEL...5 3. SCREENS DESCRIPTION...5 A. MAIN SCREEN
More informationREMOTE DISPLAY WIRELESS DECODER MK II
REMOTE DISPLAY WIRELESS DECODER MK II INSTALLATION MANUAL Part No. LED-DEC 1. Contents 1. Contents... 1 2. Equipment List... 2 3. Overview... 2 Introduction... 2 Location Selection **Important **... 2
More informationModel IQ4-PC User Manual Revision Date:
Basic Specifications Supply Volts 230V 50/60Hz ±15% 115V 50/60Hz ±15% 24V DC (isolated) ±15% Power Consumption Max. 3VA (IQ4-PC-R0) Max. 6VA (IQ4-PC-R2-PSI24-RT) Operating Temperature -5 ~ +60 C Operating
More informationRD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011
RD - 122 RACK MOUNT DIMMER OWNERS MANUAL VERSION 1.3 03/09/2011 Page 2 of 14 TABLE OF CONTENTS UNIT DESCRIPTION AND FUNCTIONS 3 POWER REQUIREMENTS 3 INSTALLATION 3 PLACEMENT 3 POWER CONNECTIONS 3 OUTPUT
More informationGeneral Information. Specifications. Introduction. Safety Instructions
General Information Introduction Thank you for your purchase of the DMX ANALYZER! That success of DMX ANALYZER is the useful features of stylish design, versatility and highly competitive price tag. There
More informationSNG-2150C User s Guide
SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120
More informationModel 5250 Five Channel Digital to Analog Video Converter Data Pack
Model 5250 Five Channel Digital to Analog Video Converter Data Pack E NSEMBLE D E S I G N S Revision 3.1 SW v2.0.1 This data pack provides detailed installation, configuration and operation information
More informationRM5 User Manual Warnings.
A RM5 User Manual Warnings. Danger Hazardous High Voltage Ground the control before servicing Remove all power and wait 10 minutes Verify that no voltage is present Failure to comply will result in death
More informationService Mode Setup Manual
For Installers Hybrid Solar Inverter & Remote Controller Service Mode Setup Manual This Service Mode Setup Manual was written exclusively for professional installers. Installers should retain this manual
More informationTransmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
More informationPCH Series Teleprompter User Manual
PCH Series Teleprompter User Manual Version: 11.2.2 i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com REVISION HISTORY REVISION AUTHOR DATE DESCRIPTION Nelson
More informationCHRONOLED Timer/Stopwatch Display
CHRONOLED Timer/Stopwatch Display Installation and operating manual BODET SA 1 rue du Général de Gaulle 49340 TRÉMENTINES FRANCE Tel. 02 41 71 72 99 Fax 02 41 71 72 02 www.bodet-sport.com Ref. 606985G
More informationXTM72 Exerciser Timer Module
Capricorn Controls DA01XTM1-1 Data & Application Note Page 1 of 6 XTM72 Exerciser Timer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products This
More informationProgrammable Video Signal Generator VG-880. Instruction Manual. Ver 1.10
Programmable Video Signal Generator VG-880 Instruction Manual Ver 1.10 Programmable Video Signal Generator VG-880 Instruction Manual 2009.9 Ver.1.10 ASTRODESIGN,Inc CONTENTS BEFORE OPERATION...v Chapter
More informationLM-TV09-4K2K. 4K video wall controller. User. Manual
LM-TV09-4K2K 4K video wall controller User Manual Catalog 1.Installation Instructions 1 2.Product Brief 2 3.Controller Installed 3 4.Remote Control Settings 6 5.Pressing Setting 7 6.Specifications 7 1
More informationInstallation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions
Installation & Operation Manual BEC PM1 Controller Time/Flow/Volume Controller Water Control Solutions Table of Contents Introduction 4 Chapter 1 Technical Data and I/O Connections 6 DC Solenoid 6 Power
More informationL, LTC, LTM, LT are registered trademarks of Linear Technology Corporation. Other product
DESCRIPTION WARNING! Do not look directly at operating LED. This circuit produces light that can damage eyes. Demo Circuit 1265 QUICK START GUIDE LTC3220/LTC3220-1 360mA Universal 18-Channel LED Driver
More informationAZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR
AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR PART NUMBER: AOM150X03 SERIES DATE: SEPT 04, 2008 1. Introduction: 1.1 About the Product AOM150Xxx 15.0 Open Frame Monitor
More informationAtlas Drop In Decoder
TCS DCC decoders provide the ultimate in control. This decoder is in # A1 Atlas Drop In Decoder 1.3 amp continuous, 2.0 amp peak motor drive plus four 100 ma function outputs Dither creates the ultimate
More informationAES-404 Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web: www.broadcast-devices.com
More information800 Displaying Series Flowmeter
TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially
More informationA summary of all menu lines available in self-diagnostic mode is shown below.
1057-03 rev A 10/08/02 Page 9/33 4. CLUSTER DIAGNOSTICS 4.1. Test at Turn On When ignition voltage is first applied to the cluster, all the tell-tales, except turn signals, turn on for 2 seconds, then,
More informationivw-ud322 / ivw-ud322f
ivw-ud322 / ivw-ud322f Video Wall Controller Supports 2 x 2, 2 x 1, 3 x 1, 1 x 3, 4 x 1 & 1 x 4 Video Wall Array User Manual Rev. 1.01 i Notice Thank you for choosing inds products! This user manual provides
More informationSECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised
SECU-16 Introduction The SECU-16 module allows 8 inputs and 8 low-current relay outputs to be added to an ADICON control system. The inputs may be supervised (switch closure), analog, or 4-20mA. Specifications
More informationDMX-LINK QUICK OPERATION
DMX-LINK QUICK OPERATION RESETTING THE CURRENT PATCH TO A ONE-TO-ONE OR ZERO PATCH The current Patch List may be initialised as a One-to-One or Zero patch as follows: 1. Ensure the Record LED is on. If
More informationModels 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack
Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack E NSEMBLE D E S I G N S Revision 1.3 SW v2.2.1 This data pack provides detailed installation, configuration
More informationUSER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0
by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MATRIX SYSTEM SX-2000 SERIES Thank you for purchasing TOA's Matrix System. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
More informationSample BD Tech Concepts LLC
XYZ Corp. Fry Controller FC-1234 Software Test Procedure Copyright 2014 Brian Dunn BD Tech Concepts LLC Last Modified: 00/00/0000 Version Tested: Date Tested: Technician: Results: 1 FC-1234 SW Test Proc.
More informationED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features
Description Page 1 of 13 The ED3 is an LCD readout that serves as a position indicator or tachometer. The ED3 can display: Speed or position of a quadrature output incremental encoder Absolute position
More informationREVISIONS LTR DESCRIPTION DATE APPROVED - Initial Release 11/5/07 MDB A ECR /9/08 MDB
REVISIONS LTR DESCRIPTION DATE APPROVED - Initial Release 11/5/07 MDB A ECR 8770 4/9/08 MDB CONTRACT NO. DRAWN BY CHECKED BY APPROVED BY DATE P. Phillips 11/2/07 TITLE M. Bester 11/5/07 SIZE A 2120 Old
More informationInstallation and Setting up Instructions for the 990 Signal Conditioning Instrument
Installation and Setting up Instructions for the 990 Signal Conditioning Instrument Contents Page 1.0 Overview... 3 2.0 Installation.. 4 2.1 Electrical connections... 4 2.2 Cable selection... 4 2.3 Electrical
More informationSC24 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface
More informationMICROMASTER Encoder Module
MICROMASTER Encoder Module Operating Instructions Issue 01/02 User Documentation Foreword Issue 01/02 1 Foreword Qualified Personnel For the purpose of this Instruction Manual and product labels, a Qualified
More informationZIRCONIA OXYGEN ANALYZER CONVERTER
Service Manual ZIRCONIA OXYGEN ANALYZER CONVERTER TYPE: ZKM INZ-TN5A0845b-E Contents 1. GENERAL...1 1.1 ZKM1 Internal constitution...1 1.2 ZKM2 Internal constitution...1 1.3 Description on display/setting
More informationBE3-GPR GENERATOR PROTECTIVE RELAY
BE3-GPR GENERATOR PROTECTIVE RELAY Behind-the-Panel Mounting Semi-flush Mounting Basler Electric s BE3-GPR generator protective relay offers multiple protective features in a single package. Its microprocessor-based
More informationVAT 20 Adjustable Frequency Drive
VAT 0 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive The VAT 0 is a small, flexible, low cost, well performing AC drive designed for use in small machines such as fans and conveyors. The drive
More informationLIGHTING BYTESIZE 483 / BIGTOP. User s Manual
LIGHTING BYTESIZE 483 / BIGTOP User s Manual VERSION 8.13 REVISION 3 JANUARY 2001 DOCUMENT NO. 801_023_3002 CONTACT DETAILS Head Office 23-31 Fonceca Street, Mordialloc Victoria 3195, Australia Telephone:
More informationUser s Manual RGB 302/304. Universal Digital Interface
User s Manual RGB 302/304 Universal Digital Interface Contents Chapter One Introduction to the RGB 302/304 RGB 302/304 Features... 1-1 SmartSave... 1-2 LCD Menu Driven Controls... 1-2 Memory Blocks and
More informationAES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:
More informationMC50BR USER / INSTALLER MANUAL. v5.0 REV. 07/ V
MC50BR USER / INSTALLER MANUAL 1 2 24V v5.0 REV. 07/2017 00. CONTT INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. THE CONTROL BOARD TECHNICAL SPECIFICATIONS PROGRAMMING PRE-RECOMDATIONS 03. INSTALLATION
More information(1) ADDENDUM FOR SYSTEM CONTROLLER WV-CU950/WV-CU650: MATRIX SWITCHER WJ-SX150 SERIES OPERATING PROCEDURES INSTALLATIONS AND CONNECTIONS
Addendum for WV-CU950, WV-CU650 and WJ-SX150 Series The descriptions in this document are applicable when WJ-SX150A Administrator Console and the firmware of this unit (matrix switcher) are Ver. 2.04 or
More informationOperating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface
Fibotec Fiberoptics GmbH Herpfer Str. 40 98617 Meiningen Germany Tel. +49 3693 8813-200 Fax. +49 3693 8813-201 www.fibotec.com Operating Manual 50mW C-Band EDFA with GPIB and RS232 Interface (Version 1.1
More informationSC24 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface
More informationUser Manual 19 LCD RP-919QD. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes.
dedicated KVM switch and rackmount screen technology User Manual 19 LCD RP-919QD 9U Quad Display Options : - DC power Designed and manufactured by Austin Hughes 751 Legal Information First English printing,
More informationINTRODUCTION INTRODUCTION
INTRODUCTION INTRODUCTION This manual describes the 5740X-400/401 Strider Speed Control, and is intended to be a guide in the installation and operation of the control. This first section, the INTRODUCTION,
More informationluxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer
DAI PCD 1-300 eading-edge/trailing-edge phase dimmer Product descripti Digital leading-edge and trailing edge phase dimmers Total cnected load: e4all input: DAI, DSI and input 1 dimmed phase (output) With
More informationModel No. ST100 VTR CONTROLLER
12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com Model No. ST100 VTR CONTROLLER For Version 6.x and 7.x Units USER MANUAL Rev 3.12 Table of Contents
More informationSmart-Encoder : Optical Incremental
1. Introduction The Smart-Encoder effectively eliminates multiple encoder part numbers by bringing intelligence and security to its design. In seconds, a four-digit LED display with two push-buttons enables
More informationMATE3 Owner s Manual Addendum
Purpose MATE3 Owner s Manual Addendum This document is an addendum to 900-0117-01-00, Revision C of the MATE3 System Display and Controller Owner s Manual. It provides descriptions of changes to the MATE3
More informationWeekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N
Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control
More informationvideo door entry system - installation instructions
4 TRADE 007 AUDIO 008 VIDEO Tel : 0870 00 00 Fax : 0870 00 00 WEB : www.planetsrs.com 8480 oronation Road Park Royal, London NW0 7QJ video door entry system installation instructions IN008v 0008 Getting
More informationFilm-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.
Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema
More informationFLAT DISPLAY TECHNOLOGY
15.0 Open Frame Monitor Model Number: LOF1506xx This product is RoHS compliant SPEC No.: SAS-1008002 Version: 0.0 Issue Date: September 6, 2010 1. Introduction: 1.1 About the Product The LOF1506xx 15.0
More informationAC182A 8 Input x 8 Output S-Video Matrix Switch with Audio
Heading AC180A 8 Input x 8 Output Composite Video Matrix Switch with Audio MARCH 2005 AC180A AC182A AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio CUSTOMER SUPPORT INFORMATION Order toll-free
More informationMONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE
More informationElectronic Lineshaft With Alignment F7 Drive Software Technical Manual
Electronic Lineshaft With Alignment F7 Drive Software Technical Manual Software Number: VSF11005X, Drive Models: CIMR-F7UXXXXXX-064, CIMR-F7UXXXXXX-065 Document Number: TM.F7SW.064, Date: 02/25/2010, Rev:
More informationTABLES Table 1. Keying Output Jumpers... Table 2. Manual Key Jumper... Table 3. Keyboard Jumpers... Table 4. Command Mode Commands...
Table of Contents THE BASICS Introduction... Front Panel... Back Panel... Connecting to a Computer... Basic Operation... Getting Started: How to Use the Menu System... Using the MFJ-495 with a... Using
More information