EtherNet/IP. 2 canale digitale SIL3 sigure ca FDI sau FDO (PP, PM) 4 canale digitale I/O non-safe. 2 mastere IO-Link sloturi V1.1. Figura 1.

Size: px
Start display at page:

Download "EtherNet/IP. 2 canale digitale SIL3 sigure ca FDI sau FDO (PP, PM) 4 canale digitale I/O non-safe. 2 mastere IO-Link sloturi V1.1. Figura 1."

Transcription

1 EtherNet/IP Comutator Ethernet integrat 10 Mbps / 100 Mbps permise 2 x conectori tată M12, 4-pini, codaţi-d, conectare Ethernet-Fieldbus Carcasă armată cu fibră de sticlă Testat la şoc şi vibraţii Electronica modulului încapsulată în răşină Grade de protecţie IP65, IP67, IP69K Conectori tată 7/8" cu 4 pini, pentru alimentare Două intrări digitale sigure SIL3 Descriere tip Număr identificare canale digitale SIL3 sigure ca FDI sau FDO (PP, PM) 4 canale digitale I/O non-safe Date de sistem Tensiune de alimentare Domeniu admisibil Conectare sursă de alimentare Izolare electrică 24 Vcc 20,4 28,8 Vcc Conector tată x 1 7/8", cu 4-pini Izolarea galvanică a grupurilor de potenţial V1 şi V2 tensiuni de până la 500 Vca 2 mastere IO-Link sloturi V1.1 Figura 1 Date de sistem Viteză de transfer Fieldbus Conectoare Fieldbus Web server Interfaă service 10 Mbps/100 Mbps 2 x M12, 4-pini, codat D Integrat Ethernet prin P1 sau P2 EtherNet/IP Adresare conform specificaţiei EtherNet/IP Conectare rapidă (QC) < 150 ms Inel nivel dispozitiv (DLR) suportat Conexiuni clasă 1 3 Figura 2 Safety Data PL acc. to DIN EN :2008 e Categorie conform DIN EN : SIL according IEC Useful Lifetime 20 Jahre (EN ISO ) Safety Inputs OSSD Low level signal voltage EN Type 1 ( < 5 V; < 0.5 ma) High level signal voltage EN Tip 1 ( > 15 V; > 2 ma) Max. OSSD supply per channel 2 A per C0, C1, C2, C3, 1.5 A la 70 C ilustrată în Figura 1 Max. tolerance test pulse width 1 ms Interval between 2 test pulses, minimum 20 ms la durată impuls test la 1 ms 15 ms la durată impuls test la 0,5 ms Safety Inputs floating/antivalent Max. loop resistance Max. cable length Test pulse, typical Test pulse, maximum Alimentare senzor Interval between 2 test pulses, minimum Additional information < 150 ò max. 1 μf la 150 ò Limitat de capacitatea liniei 0,6 ms 0,8 ms Sursă de alimentare V AUX1/T1 max. 2 A 900 ms Nu e permisă nicio conexiune la potenţial extern 1 / 7 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ

2 Safety Outputs Output current in off state Output current in off state Test pulse, typical Test pulse, maximum Interval between 2 test pulses, typical Interval between 2 test pulses, minimum Alimentare actuator Max. output current Additional information < 5 V < 1 ma adecvate pentru intrări conform EN Tip 1 0,5 ms 1,25 ms 500 ms 250 ms Sursă de alimentare V AUX1/T1 max. 2 A 2 A (rezistiv) 1 A (inductiv) Sarcina trebuie să aibă inerţie mecanică sau electrică pentru a suporta impulsurile test. Când este configurată ca ieşire digitală PPM, polul negativ al sarcinii trebuie legat de terminalul-m al ieşirii corespunzătoare (Pin 2). intrări digitale Connectivity inputs Tip de intrare Prag de comutare Nivel de tensiune în stare "Low" Nivel de tensiune pentru semnal "High" Nivel de curent pentru semnal "Low" Curent pentru nivel "High" al semnalului Întârziere la intrare Alimentare senzor Izolare electrică M12, 5-pini PNP EN Tip 3, PNP < 5 V > 11 V < 1.5 ma > 2 ma 2,5 ms C4, C5: FSO 0 max. 2 A; 500 ma per intrare C6: V AUX1 max. 2 A C7: FSO1 max. 2 A izolare galvanică faţă de P1/P2, tensiuni de până la 500 Vcc ieşiri digitale Connectivity outputs Tip de ieşire Tipul de diagnoză a ieşirilor Tensiune de ieşire Curent de ieşire pe canal Protecţie la scurtcircuit Alimentare actuator Izolare electrică M12, 5-pin PNP dignoză la nivel de canal 24 Vcc din potenţial grup 0.5 A, protejat la scurtcircuit, max. 2 A (rezistiv)/ 1 A (inductiv) toate ieşirile standard Da C4, C5: FSO 0 max. 2 A; 500 ma per ieşire C6: V AUX1 max. 2 A C7: FSO1 max. 2 A izolare galvanică faţă de P1/P2, tensiuni de până la 500 Vcc IO-Link Număr de canale 2 IO-Link specification Version 1.1 IO-Link port type Clasa A & Clasa B Tip de cadru supports all specified frame types Dispozitive acomodate max. 32 byte input/32 byte output Viteză de transmisie 4.8 kbps (COM 1) / 38.4 kbps (COM 2) / 230 kbps (COM 3) Sursă de alimentare Sursă de alimentare V AUX1 max. 2 A 2 / 7 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ

3 Conformitate standard/directivă Test vibraii Acceleraţie până la 20 g conform EN Test la şocuri mecanice conform EN Test la cădere liberă conform EN /IEC Compatibilitate electromagnetică (interferene) conform EN Date de sistem Dimensiuni (l x L x h) 60.4 x x 39mm Temperatura de funcţionare C Temperatura de depozitare C Altitude max m Clasă de protecţie IP65 IP67 IP69K material carcasă PA6-GF30 Culoarea carcasei negru Window material Lexan Material şurub Oţel inoxidabil 303 Material etichetă Policarbonat Fără halogeni Da Montare 2 găuri de montare Ø 6.3 mm The data sheet serves as advance information. For definitive values see the corresponding product manual. In this respect, no liability for completeness and accuracy can be applied to the content of this data sheet. 3 / 7 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ

4 Cablu Ethernet (exemplu): RSSD-RSSD-441-2M/S2174 Nr. ID M12 1 Ethernet RKC4.5T-2-RSC4.5T/TXY Nr. ident M12 1 intrare de siguranţă RKC4.5T-2-RSC4.5T/TXY Nr. ident M12 1 Port I/O safety RKC4.5T-2-RSC4.5T/TXL Nr. ident M12 1 Port I/O Conectarea unui dispozitiv clasa A: RKC4T-2-RSC4T/TXL Nr. ident Conectarea unui dispozitiv clasa B: RKC4.5T-2-RSC4.5T/TXL Nr. ident M12 1 IO-Link 4 / 7 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ

5 Conectarea unui dispozitiv clasa A: RKC4T-2-RSC4T/TXL Nr. ident Conectarea unui dispozitiv clasa B: RKC4.5T-2-RSC4.5T/TXL Nr. ident M12 1 IO-Link Cablu de alimentare (exemplu): RKM43-1-RSM43 Nr. ID /8'' Alimentare 5 / 7 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ

6 Led stare modul LED Culoare Stare Descriere ETH1/ETH2 Verde Ethernet Link (100 Mbps) Ethernet comunicaţie (100 Mbps) Nu există conexiune Ethernet BUS Verde Conexiune activă la un master Pregătit Conflict adresă IP sau Mod Revenire sau timeout Modbus / Verde Alternează Comanda clipire activă ERR Verde Diagnostic dezactivat Diagnostic activat PWR Green Power supply V 1 OK Stare LED I/O LED Culoare Stare Descriere 0 3 Verde Canal activ Autonegociere sau aşteptare adresare prin DHCP/Boot-P V 1 power off or below defined tolerance of 18 V Autotest Discrepanţe Circuit încrucişat 4 7 Verde Canal activ Autotest (doar intrare) Discrepanţă, supratensiune (doar ieşire) Circuit încrucişat 8 11 Verde Canal activ 12, 14 (IO-Link Port 1 şi 2) Verde / Alternează Supratensiune (doar ieşire) Suprasarcină la alimentare Canal activ şi suprasarcină la alimentare Verde Comunicaţie IO-Link, date de proces valide Mod IO-Link Comunicaţie IO-Link, date de proces invalide 12, 14 (IO-Link Port 1 şi 2) Mod SIO Alimentare IO-Link OK, nu există Comunicaţie IO-Link Port inactiv Verde Există semnal Intrare digitală Nu există semnal Intrare 13, 15 Verde Intrare sau ieşire digitală activă Ieşire activă cu suprasarcină/scurtcircuit Suprasarcină la alimentare Intrare sau ieşire inactivă 6 / 7 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ

7 Mapare date proces ale protocoalelor unice Pentru mai multe dtalii despre protocoalele corespunzătoare, consultaţi manualul. 7 / 7 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog

More information

Read/Write Head TNSLR-Q42TWD-H1147

Read/Write Head TNSLR-Q42TWD-H1147 Rectangular, height 42.5 mm Active face on top Plastic, PA12-GF30 /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030424 Mounting conditions Non-flush Ambient temperature -25 +70 C Operating

More information

Capacitive sensor BCT5-S18-UP6X2T-H1151

Capacitive sensor BCT5-S18-UP6X2T-H1151 M18 1 threaded barrel Plastic, PA12-GF30 Teach-in and configuration via buttons on the device, pin 5 and IO-Link Wiring Diagram Functional principle Type designation Ident no. 2101100 Remark to product

More information

Read/Write Head TNLR-Q80L400-H1147L

Read/Write Head TNLR-Q80L400-H1147L For roller conveyors The approach direction of the data carrier can be both, diagonal as well as longitudinal to the read/write head. Rectangular, 80 x 400 mm, height 25 mm Active face on top Plastic,

More information

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8 Type code Ident no. 1545077 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between

More information

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7 8 mm connector, 4-pin Visible red light Programming via teach cable or multi-function button Operating voltage: 10 30 VDC IO-Link 2 x PNP output, changeover contact Light/dark operation Wiring Diagram

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

BL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P

BL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P On-Machine kompakt fieldbus I/O blokları CANopen slave 10, 20, 50, 125, 250, 500, 800, or 1000 kbps Two 5-pin M12 male receptacles for fieldbus connection 2 rotary coding switches for node-address IP 69K

More information

Read/write head TN-CK40-H1147

Read/write head TN-CK40-H1147 Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated only via BL ident

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 610 mm Laser class 1, red, 655 nm, acc.

More information

Read/Write Head TN-M30-H1147

Read/Write Head TN-M30-H1147 Threaded barrel, M30 x 1.5 Chrome-plated brass /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030004 Mounting conditions Non-flush Ambient temperature -25 +70 C Operating voltage 10 30

More information

Read/write head TN-M18-H1147

Read/write head TN-M18-H1147 Threaded barrel, M18 x 1 Chrome-plated brass Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated solely via BLident interface module M12 x 1 male,

More information

BL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT

BL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 310 mm Laser class 1, red, 655 nm, acc.

More information

Read/Write Head TN-CK40-H1147

Read/Write Head TN-CK40-H1147 Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030006 Mounting conditions Non-flush Ambient temperature -25

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 100 mm Laser class 1, red, 655 nm, acc.

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 300 mm Laser class 1, red, 655 nm, acc.

More information

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151 Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:

More information

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment

More information

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

EtherCAT Set in IP20 TI-BL20-E-EC-S-4

EtherCAT Set in IP20 TI-BL20-E-EC-S-4 A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BLident M12 extension

More information

BL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC

BL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 4 analog

More information

Rotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181

Rotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181 Clamping flange, Ø 58 mm Solid shaft, Ø 10mm x 20mm Optical measuring principle Shaft material, stainless steel Protection class IP67 on the shaft side -40 +85 C Max. 6000 rev/min (continuous operation

More information

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 16 bits singleturn Process value in 32 bit telegram 3 error bits 16 bits singleturn 15

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM8

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM8 External antenna (RG58 RP-SMA connection) Integrated signal strength indicator Configuration via DIP switch Modbus RTU communication, RS485 interface Deterministic data transmission Frequency hopping FHSS

More information

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Contactless encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED LED indicates measuring range Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024,

More information

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ Transmission of process value and parametrization via IO-link Cable with male end, PVC, M8 x 1, 4-pin, 150 mm Protection class IP67 LED, all-round visible Coaxial optics Sensitivity adjusted via teach

More information

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. output 25 bit, Gray-coded clock rate: 62.5 KHz 1 MHz Single or multiturn, length

More information

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. SSI output 25 bit, Gray-coded SSI clock rate: 62.5 KHz 1 MHz Single or multiturn,

More information

Set for Simple I/O Communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-2

Set for Simple I/O Communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-2 Tip kodu İdent no. 1545074 Kanal sayısı 2 Boyutlar (W x L x H) 72.5 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between interface

More information

TW-R30-K2. FRAM memory 2 kb. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

TW-R30-K2. FRAM memory 2 kb. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission FRAM memory 2 kb Functional principle The HF read/write heads operating at a frequency of 13.5 MHz, form a transmission zone the size of which (0 0 mm) varies, depending on the combination of read/write

More information

Mobile data carrier TW-L49-46-F-B128

Mobile data carrier TW-L49-46-F-B128 EEPROM, memory 128 byte Functional principle The HF read/write heads operating at a frequency of 13.56 MHz, form a transmission zone the size of which (0 500 mm) varies, depending on the combination of

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151 Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output

More information

TW-R16-B128. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

TW-R16-B128. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission EEPROM, memory 8 byte Functional principle The HF read/write heads operating at a frequency of 13.56 MHz, form a transmission zone the size of which (0 0 mm) varies, depending on the combination of read/write

More information

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151 Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog

More information

Connectivity for Ethernet

Connectivity for Ethernet Industrial Ethernet standards such as Modbus TCP, EtherNet/IP, PROFINET and Ether- CAT have firmly established themselves in automation technology. These real-time Ethernet solutions differ both in terms

More information

Inductive coupling. 10 mm +/-0.2 mm

Inductive coupling. 10 mm +/-0.2 mm Data carrier for direct mounting on metal The mounting position (arrow) as well as the alignment of the data carrier towards the read/write head must be observed under all circumstances in order to achieve

More information

ANEXA NR. 1. Caracteristicile tehnice ale interfeţelor echipamentelor. Exemplu schema de interconectare TRONSON XX: A A1 A2 A3 - B STM-4 A2 A3 STM-1

ANEXA NR. 1. Caracteristicile tehnice ale interfeţelor echipamentelor. Exemplu schema de interconectare TRONSON XX: A A1 A2 A3 - B STM-4 A2 A3 STM-1 SERVIIUL DE TELEOUNIAŢII SPEIALE SEŢIUNEA II AIET DE SARINI ONTRAT DE FURNIZARE EHIPAENTE DE OUNIAŢII PENTRU IPLEENTAREA PROIETULUI REŞTEREA APAITĂŢII DE INTERONETARE A SISTEELOR INFORATIE ŞI BAZELOR DE

More information

Circuite Basculante Bistabile

Circuite Basculante Bistabile Circuite Basculante Bistabile Lucrarea are drept obiectiv studiul bistabilelor de tip D, Latch, JK şi T. Circuitele basculante bistabile (CBB) sunt circuite logice secvenţiale cu 2 stări stabile (distincte),

More information

TTX260 investiţie cu cost redus, performanţă bună

TTX260 investiţie cu cost redus, performanţă bună Lighting TTX260 investiţie cu cost redus, performanţă bună TTX260 TTX260 este o soluţie de iluminat liniară, economică şi flexibilă, care poate fi folosită cu sau fără reflectoare (cu cost redus), pentru

More information

Ghid de instalare pentru program NPD RO

Ghid de instalare pentru program NPD RO Ghid de instalare pentru program NPD4758-00 RO Instalarea programului Notă pentru conexiunea USB: Nu conectaţi cablul USB până nu vi se indică să procedaţi astfel. Dacă se afişează acest ecran, faceţi

More information

Modalităţi de redare a conţinutului 3D prin intermediul unui proiector BenQ:

Modalităţi de redare a conţinutului 3D prin intermediul unui proiector BenQ: Modalităţi de redare a conţinutului 3D prin intermediul unui proiector BenQ: Proiectorul BenQ acceptă redarea conţinutului tridimensional (3D) transferat prin D-Sub, Compus, HDMI, Video şi S-Video. Cu

More information

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital

More information

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions Your Global Automation Partner RU CK40 RU CP40 Ultrasonic Sensors Operating Instructions Contents 2 Hans Turck GmbH & Co. KG T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com Contents 1

More information

The full range of performance

The full range of performance sensors sensors P sensors PS series series The full range of performance The sensors of this series cover all important pressure ranges from -1 +600 bar with an accuracy of 0.5% f.s.. Bar, psi and further

More information

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing ADVANCED ultrasonic sensors with analog output Dimensioned drawing en 07-2017/02 50124880 4...20 ma 0...10 V 25 400mm 150 1300mm 15-30 V DC We reserve the right to make changes PAL_DMU418BX3LTVC_en_50124880.fm

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Multi-functional safety relay modules PROTECT SRB-E

Multi-functional safety relay modules PROTECT SRB-E Multi-functional safety relay modules PROTECT SRB-E PROTECT SRB-E The configurable User-friendly Up to 16 different applications can be selected Monitoring of all conventional safety switchgear Safety

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors) More Precision scancontrol // 2D/D laser scanner (laser profile sensors) 1 scancontrol 26x gapcontrol 26x1 Technical details and versions - z-axis measuring up to 265mm - x-axis measuring up to 14.5mm

More information

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO Ceramic Sensor accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire:

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications. MIRAL The Admiral Type family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications. Its features include: Extremely easy connection and

More information

Technical data. General specifications. Indicators/operating means

Technical data. General specifications. Indicators/operating means Model Number Single head system Features Sensor head bidirectional and rotatable Function indicators visible from all directions Quick mounting bracket Selectable sound lobe width Programmable Diagrams

More information

Ghid de instalare in limba romana TE100-S16 TE100-S24

Ghid de instalare in limba romana TE100-S16 TE100-S24 Ghid de instalare in limba romana TE100-S16 TE100-S24 Table of of Contents Contents... 1. Inainte de Incepe... 2. Instalare fizicã... 3. Caracteristici tehnice... Rezolvare a problemelor ce ar putea sã

More information

Microincrements IP67-related solutions

Microincrements IP67-related solutions technology microincrements Keywords microincrements Distributed Clocks EtherCAT EtherCAT Box IP 67 EP50 encoder Microincrements IP67-related solutions This application example describes how an EP50 EtherCAT

More information

AC diagonal module Ø 200 mm

AC diagonal module Ø 200 mm max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:

More information

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

EZ-SCREEN LS. Safety Light Screen

EZ-SCREEN LS. Safety Light Screen EZ-SCREEN LS Safety Light Screen Quick, easy configuration no DIP switches or software to configure End-to-end sensing Heavy-duty aluminum housing and recessed window to avoid damage in harsh environments

More information

Pressure transmitter COMPACT IO-Link,

Pressure transmitter COMPACT IO-Link, Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic

More information

Pressure sensors with display

Pressure sensors with display 412 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 sensors P sensors PK series series Multifaceted pneumatic specialists The PK pressure sensors are especially designed for pneumatic

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

Aplicatii ale programarii grafice in experimentele de FIZICĂ

Aplicatii ale programarii grafice in experimentele de FIZICĂ Aplicatii ale programarii grafice in experimentele de FIZICĂ Autori: - Ionuț LUCA - Mircea MIHALEA - Răzvan ARDELEAN Coordonator științific: Prof. TITU MASTAN ARGUMENT 1. Profilul colegiului nostru este

More information

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

Sensor technologies Proximity sensors Series ST4. Brochure

Sensor technologies Proximity sensors Series ST4. Brochure Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode

User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode Transition Networks F-SM-MM-02 Fast Ethernet Media Converter extends Fast Ethernet or ATM over singlemode

More information

Amplifier for fiber optics. Dimensioned drawing

Amplifier for fiber optics. Dimensioned drawing Amplifier for fiber optics Dimensioned drawing up to 525mm up to 120mm 10-30 V DC 3-digit display for indicating and setting the switching threshold NEW: AutoSet function for easy sensor adjustment Menu

More information

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode Transition Networks F-SM-MM-06 Ethernet Media Converter extends ATM or SONET over singlemode fiber-optic cable

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

A/D and D/A convertor 0(4) 24 ma DC, 16 bits

A/D and D/A convertor 0(4) 24 ma DC, 16 bits A/D and D/A convertor 0(4) 24 ma DC, 6 bits ZAT-DV The board contains independent isolated input A/D convertors for measurement of DC current signals 0(4) ma from technological convertors and sensors and

More information

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1. Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options

More information

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors) More Precision scancontrol // 2D/D laser scanner (laser profile sensors) 12 scancontrol 29x gapcontrol 29x1 Technical details and versions zaxis measuring up to 265mm xaxis measuring up to 14.5mm Profile

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance

More information

GFT channel Time Interval Meter

GFT channel Time Interval Meter Key Features Five-channel Time-Interval Meter: One Start and four Stops - 13 picosecond resolution - < 50 picosecond RMS jitter - > 100 second range - 10 MHz sample rate per channel Common GATE input Input

More information

VISUAL FOX PRO VIDEOFORMATE ŞI RAPOARTE. Se deschide proiectul Documents->Forms->Form Wizard->One-to-many Form Wizard

VISUAL FOX PRO VIDEOFORMATE ŞI RAPOARTE. Se deschide proiectul Documents->Forms->Form Wizard->One-to-many Form Wizard VISUAL FOX PRO VIDEOFORMATE ŞI RAPOARTE Fie tabele: create table emitenti(; simbol char(10),; denumire char(32) not null,; cf char(8) not null,; data_l date,; activ logical,; piata char(12),; cap_soc number(10),;

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors) More Precision scancontrol // 2D/D laser scanner (laser profile sensors) 12 scancontrol 29x gapcontrol 29x1 Technical details and versions - z-axis measuring range up to 265mm - x-axis measuring range

More information

Electrical connection

Electrical connection (I)GSU 14C Ultrasonic Label Fork Dimensioned drawing en 06-2011/12 50109234-01 4mm 12-30 V DC 4 m/s We reserve the right to make changes DS_IGSU_14C_en.fm Ultrasonic forked sensor for universal application

More information

Your Global Automation Partner. Ultrasonic Sensors

Your Global Automation Partner. Ultrasonic Sensors Your Global Automation Partner Ultrasonic Sensors At TURCK, we understand that not every application is the same. That s why we dedicate ourselves to finding the optimal engineered solution for every application;

More information

Generator protection relay

Generator protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Off-the-shelf generator protection relay for small and medium sized power generators Three-phase time overcurrent and

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

GFT Channel Digital Delay Generator

GFT Channel Digital Delay Generator Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Fours Triggers Three are repetitive from three

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P n n n n n Compact design: 59 mm mounting depth for single or multiturn Aids for start up and operation: diagnostic LED, preset key with optical response Parameterization: Resolution, code type, direction,

More information

User Manual KUNBUS-PRS

User Manual KUNBUS-PRS User Manual KUNBUS-PRS DO0236R00 14/09/2016 Table of content KUNBUS Table of content 1 Working with PRS... 3 1.1 Validity... 3 1.2 User... 3 1.3 Symbols... 3 1.4 Safe use... 4 1.5 Limitation of Liability...

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes