MEMORANDUM. Date: January 11, 2018

Size: px
Start display at page:

Download "MEMORANDUM. Date: January 11, 2018"

Transcription

1 MEMORANDUM Date: January 11, 2018 To: From: Subject: Mr. Merton Auger, City Administrator, Minnesota Justin L. Kannas, Assistant City Engineer Capital Improvement Plan, Minnesota Project No.: W The following is a prioritized list of street and utility capital improvement projects that we recommend the consider pursuing: 1) Sanitary Sewer Repairs (2 nd Ave. S. Area, 7 th St. S. Area and Upplanda Area) In February 2017 there was approximately 16,000 linear feet of vitrified clay pipe sanitary sewer mainline that was televised in four areas of the City. The televising showed deficiencies in several areas of the system. Attached are maps of the four areas showing the pipe condition in each area. As a short term fix to address the most critical deficiencies in the sanitary sewer system in the 2 nd Ave. S. area (Figure 1), 7 th St. S. area (Figure 2) and Upplanda area (Figure 3), a project consisting of less obtrusive repairs that include spot lining, lining of entire sewer mains and some spot repairs requiring excavations should be completed. This would address all of the pipes that were rated in Poor or Critical condition (shown in orange and red on the attached figures). The figures show the locations of the proposed sewer lining and spot repairs. The estimated cost to complete these repairs is $360,000. 2) Sanitary Sewer and Watermain - Douglas Drive Area Due to the combined condition of the streets, watermain and sanitary sewer system in the Douglas Drive area (Figure 4), it is recommended that a full street and utility reconstruction be completed to address the street and utility deficiencies in this area. The watermain is cast iron pipe constructed in The watermain has experienced breaks every year for the past several years. The sanitary sewer system is clay tile pipe constructed in Tree roots are highly prevalent in the sewer mains and continue to grow back despite City crews performing maintenance to remove roots and applying chemicals to slow the growth of tree roots in this area. Infiltration is also high in this area. A full reconstruction would provide the most cost effective, long term solution to address all of the current deficiencies in this area. The total estimated project cost is $1,700,000. 3) Sanitary Sewer and Watermain 2 nd Street S. and 3 rd Ave. S. Area (Southeast Area Phase 3) Due to the combined condition of the streets, watermain and sanitary sewer system in this area, it is recommended that a full street and utility reconstruction be completed to address the street and utility deficiencies in this area. The watermain is cast iron pipe constructed in The watermain has experienced breaks in this area in the past, but no breaks have occurred in the past few years. Valves, hydrants and water shut offs are approaching 80 years old and many of them do not operate. The sanitary sewer system is clay tile pipe constructed in Tree roots are highly prevalent in the sewer mains and continue to grow back despite City crews performing H:\Buff\W15548\1_Corres\ Auger Project Scope mmo.docx

2 Mr. Merton Auger January 11, 2018 Page 2 regular maintenance to remove roots in this area. Infiltration is also high in this area. A full reconstruction would provide the most cost effective, long term solution to address all of the current deficiencies in this area. The total estimated project cost is $1,600,000. 4) Additional Sanitary Sewer System Evaluation It is recommended that the City continue with their sanitary sewer televising program each year until all clay pipe sewer has been televised and evaluated. Additionally, all sewer mains located in proposed street overlay or street reclaim areas for 2018 should be televised during the 2018 calendar year. Based upon televising, the sewer system can further be evaluated for any needed repairs prior to street surfacing being completed. 5) Watermain - Sigrid Drive The watermain along Sigrid Drive has experienced multiple breaks over the past three to four years. The watermain is cast iron pipe constructed in Due to the multiple breaks over the past several years and the history of cast iron pipe being susceptible to breaks, it is recommended that replacement of this watermain be considered in the future. The estimated costs for using pipe bursting trenchless technology and open cut traditional replacement are very similar. Both methods could be bid to determine the lowest overall actual cost. The estimated total cost to replace the Sigrid Drive watermain is $350,000. If you have any questions on any of the above items, please feel free to contact me.

3 is affecting function 3717 of the main or will soon 3717 Did not televise impact function of the main (i.e. roots 2109 coming into main from sevice) Santary Sewer not Televised Good Condition (3532 ft) Fair Condition- Minor Issues; Consider Lining or Replacement Long Term (4559 ft) Poor Condition- Plan for repairs 726 or replacement in near term future; 727 Continue to monitor condition & Could not Televise until repairs are made (2949 ft) Critical Condition- Require immediate repairs or replacement; monitor condition & complete regular maintenance until repairs are made (897 ft) Sanitary Manhole Parcels Proposed Lining Proposed Replacement with Reconstruction Project Could not Televise Map Document: \\arcserver1\gis\buff\_basemap\esri\maps\2018\buff_sewer_issues_map_firgure1_8x11.mxd Date Saved: 1/10/2018 1:00:12 PM V IK IN G D R 1ST AVE S MONTROSE BLVD CEDAR PT 8TH ST S 12TH ST S HIGHVIEW LN ND AVE S GkWX 2110 SIGRID DR ANDREA CIR HIGHLAND LN INNSBROOK LN TH ST S Legend Figure 1 4TH AVE S 10TH ST S 5TH AV E S 21335

4 Figure 2 is affecting function of the main or will soon impact function of the main (i.e. roots coming into main from sevice) PARK LN 1316 Legend ND AVE S Santary Sewer not Televised Sanitary Manhole 2117 Good Condition (334 ft) Fair Condition- Minor Issues; 600 Consider Lining or Replacement Long Term (1574 ft) Poor Condition- Plan for repairs602 or replacement in near term future; Continue to monitor condition & 602 until repairs are made (84 ft) 604 Critical Condition- Require 200 immediate repairs or replacement; monitor condition & complete 606 regular maintenance until repairs are made (0 ft) Parcels Map Document: \\arcserver1\gis\buff\_basemap\esri\maps\2018\buff_sewer_issues_map_firgure2_8x11.mxd Date Saved: 1/10/ :44:36 PM ST AVE S CEDAR PT TH ST S MONTROSE BLVD GkWX Proposed Lining Proposed Replacement with 616 Reconstruction Project

5 Figure 3 Map Document: \\arcserver1\gis\buff\_basemap\esri\maps\2018\buff_sewer_issues_map_firgure3_8x11.mxd Date Saved: 1/10/ :44:07 PM is affecting function of the main or will soon impact function of the main (i.e. roots coming into main from sevice) 1 4 T H S T N E 232 RIDGE STONE PL GAGNEF PL RD AVE NE Sag in Pipe UPPLANDA ST Did Not Televise RATTVIK CIR L E K S A N D L N Parcels Legend A R L A N D A C IR ARLANDA AVE Poor Condition- Plan for repairs 323 or replacement in near term future; Continue 325 to monitor condition & until repairs are made (37 ft) 1622 Critical Condition- Require immediate repairs or replacement; 5448 monitor condition & complete regular maintenance until repairs are made (59 ft) Sanitary Manhole Proposed Lining VENDELL ST 6TH AVE NE 1 Santary Sewer not Televised SUNSET ST Proposed Replacement with Reconstruction Project Good Condition ( ft) Fair Condition- Minor Issues; Consider Lining or Replacement Long Term (1574 ft) 847 JUNIPER LN

6 Figure is affecting function of the main or will soon 4616impact function of the main (i.e. roots 1719 coming into main from sevice) Legend Santary Sewer not Televised 1750 Good Condition ( ft) Critical Condition- Require immediate repairs or replacement; monitor condition & complete regular maintenance until repairs are made (630 ft) 103 Sanitary Manhole Parcels GREENBRIAR LN 9560 Fair Condition- Minor Issues; Consider Lining or Replacement Long Term (1129 ft) Poor Condition- Plan for repairs or replacement in near 401 term future; 300 Continue to monitor condition & until repairs are made ( ft) 218 Map Document: \\arcserver1\gis\buff\_basemap\esri\maps\2018\buff_sewer_issues_map_firgure4_8x11.mxd Date Saved: 1/10/ :53:14 PM PULASKI RD Proposed Lining Proposed Replacement with Reconstruction Project DOUGLAS DR

DESIGN CONSULTING ENGINEERS Engineers, Geotechnical, Environmental & Material Scientists

DESIGN CONSULTING ENGINEERS Engineers, Geotechnical, Environmental & Material Scientists DESIGN CONSULTING ENGINEERS December 12, 2013 Mr. Mark Kozlowski, P.E. Design Manager Chicago Public Schools Capital Improvement Program 125 S. Clark St. ; 17 th Floor Chicago IL, 60603-5322 RE: Ravenswood

More information

THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016

THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016 THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016 TABLE OF CONTENT 1.0 SCOPE OF WORK... 3 1.1 GENERAL... 3 1.2 OBJECTIVES:...

More information

SECTION 3 SPECIFICATIONS FOR TELEVISION INSPECTION OF SANITARY AND STORM SEWER 0053

SECTION 3 SPECIFICATIONS FOR TELEVISION INSPECTION OF SANITARY AND STORM SEWER 0053 SECTION 3 SPECIFICATIONS FOR TELEVISION INSPECTION OF SANITARY AND STORM SEWER 0053 3.1 INTENT It is the intent of this Specification to describe the services to be provided. 1) The Closed Circuit Television

More information

ArcGIS Server Implementation for the City of Westfield

ArcGIS Server Implementation for the City of Westfield ArcGIS Server Implementation for the City of Westfield Eric Becker & Leane Welsh Westfield Public Works Department (WPWD) February 20, 2008 Westfield Public Works Department ArcGIS Server Implementation

More information

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved. Tab 10 - The NESC and Underground Applications Restricted Siemens Industry, Inc. 2017 All rights reserved. siemens.com/poweracademy The National Electric Safety Code (NESC) The NESC provides guidelines

More information

Specifications For CCTV Inspection Of Sanitary & Storm Sewers (Revised Aug. 2018)

Specifications For CCTV Inspection Of Sanitary & Storm Sewers (Revised Aug. 2018) Specifications For CCTV Inspection Of Sanitary & Storm Sewers (Revised Aug. 2018) 1.0 INTENT It is the intent of this Specification to describe the services to be provided. 1) The Closed-Circuit Television

More information

SECTION 25 CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER LINES

SECTION 25 CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER LINES 2017 - SECTION 25 CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER LINES 25.1 GENERAL This section of the specifications shall form a part of the contract documents and should be read in conjunction with

More information

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 409 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES

More information

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 409 NOVEMBER 2013 CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES

More information

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION INSPECTION OF PIPELINES

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION INSPECTION OF PIPELINES ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 409 NOVEMBER 2009 CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES

More information

City of Newport Park Board Meeting September 22, 2016

City of Newport Park Board Meeting September 22, 2016 City of Newport Park Board Meeting September 22, 2016 1. CALL TO ORDER 2. ROLL CALL Board Members present Anita Perkins; Paul Hansen Heidi Tweeten; Board Members absent Emily White; John Graber Also present

More information

3 Locating and Marking Products DOCUMENT OBSOLETE

3 Locating and Marking Products DOCUMENT OBSOLETE 3 Locating and Marking Products This was Wall Street, 1921 2 Imagine what it s like down there today. 3 Spotting the target with Dynatel Cable/Fault Locators. The opening photos in this brochure show the

More information

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION 1.0 General 1.1 The work covered by this section consists of providing all labor, equipment, insurance, accessories, tools, transportation, supplies,

More information

Appendix 1 CLOSED-CIRCUIT TELEVISION INSPECTION

Appendix 1 CLOSED-CIRCUIT TELEVISION INSPECTION Appendix 1 CLOSED-CIRCUIT TELEVISION INSPECTION GENERAL 1.1 SUMMARY A. The Vendor shall f urnish all labor, materials, equipment, transportation, and incidentals as shown, specified or require d for closed-circuit

More information

FIRST ADDENDUM TO THE MEMORANDUM OF UNDERSTANDING Fiber Optic Network Agreement

FIRST ADDENDUM TO THE MEMORANDUM OF UNDERSTANDING Fiber Optic Network Agreement ADDENDUM 1 FIRST ADDENDUM TO THE MEMORANDUM OF UNDERSTANDING Fiber Optic Network Agreement Between The City of Lawrence, Kansas ( The City ) and The University of Kansas, a public educational institution

More information

CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES

CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 409 APRIL 1999 CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES 409.03

More information

Lancaster Performing Arts Center RENTAL FEES and Policies

Lancaster Performing Arts Center RENTAL FEES and Policies Physical Address: Mailing Address: City of Lancaster 750 West Lancaster Blvd ATTN: LPAC Rental Office Lancaster, CA 93535-3816 44933 Fern Ave LPAC Rental Administrator (661) 723-5932 www.lpac.org PMartindale@CityofLancasterCA.org

More information

1422 TAMARIND AVENUE HOLLYWOOD, CA 90028

1422 TAMARIND AVENUE HOLLYWOOD, CA 90028 OFFERING MEMORANDUM 17 UNITS WITH PARKING IN THE HEART OF HOLLYWOOD PRESENTED BY Kenny Stevens BRE# 01090251 310.963.7851 kenny@prosserstevens.com LOCATION OVERVIEW Location Overview Hollywood Developments

More information

AMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES

AMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES Works and Emergency Services CITY OF TORONTO WATER AND WASTEWATER SERVICES STANDARD CONSTRUCTION SPECIFICATIONS TS 409 November 2010 AMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED

More information

C. Anthony Pessarra Sugar Plum Ln, Houston, TX 77062

C. Anthony Pessarra Sugar Plum Ln, Houston, TX 77062 C. Anthony Pessarra 281.488.2055 KeyArts@att.net 14703 Sugar Plum Ln, Houston, TX 77062 To: November 11.10.12 The Members of the Session - First Presbyterian Church, Galveston Greetings! INTRODUCTION I

More information

DISCLAIMER. This document is current at the date of downloading. Hunter Water may update this document at any time.

DISCLAIMER. This document is current at the date of downloading. Hunter Water may update this document at any time. DISCLAIMER This Standard Technical Specification was developed by Hunter Water to be used for construction or maintenance of water and/or sewerage works that are to become the property of Hunter Water.

More information

May 2016 DIVISION 3 - CW 2145-R4 TABLE OF CONTENTS

May 2016 DIVISION 3 - CW 2145-R4 TABLE OF CONTENTS May 2016 CW 2145 - SEWER AND MANHOLE INSPECTION TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Referenced Standard Construction Specifications... 1 3. CONSTRUCTION METHODS... 1 3.1 Inspection

More information

GROUNDWATER MONITORING DATA RELEASE 2011 SAMPLING EVENT HARSHAW CHEMICAL COMPANY FUSRAP SITE

GROUNDWATER MONITORING DATA RELEASE 2011 SAMPLING EVENT HARSHAW CHEMICAL COMPANY FUSRAP SITE GROUNDWATER MONITORING DATA RELEASE 2011 SAMPLING EVENT HARSHAW CHEMICAL COMPANY FUSRAP SITE U.S. Army Corps of Engineers Building Strong Buffalo District April 2012 Formerly Utilized Sites Remedial Action

More information

Six Year Capital Plan Fiscal Year

Six Year Capital Plan Fiscal Year Six Year Capital Plan Fiscal Year 2018-2023 Updated-May 2017 Fiscal Year 2018 Capital Projects Update Original Restrooms Update the original restrooms on the mezzanine and lower lobby to match the new

More information

Cleora Clark Wheeler student notebook and bookplates, KA.0061

Cleora Clark Wheeler student notebook and bookplates, KA.0061 Cleora Clark Wheeler student notebook and bookplates, 1910-1960 KA.0061 This finding aid was produced using the Archivists' Toolkit February 28, 2017 Describing Archives: A Content Standard Kellen Design

More information

Page Number Official Detail Name Contact Title Primary Contact E mail Secondary Contact E mail

Page Number Official Detail Name Contact Title Primary Contact E mail Secondary Contact E mail MANHOLE SPECIFIC STR 11 1 Control Manhole Metered Program Manager Anne.Marie.Smrchek@cityoffortwayne.org Kristen.Buell@cityoffortwayne.org STR 11 2 Control Manhole Non Metered Program Manager Anne.Marie.Smrchek@cityoffortwayne.org

More information

Technical Information Guide PLEASE FORWARD TO TECHNICAL DIRECTOR

Technical Information Guide PLEASE FORWARD TO TECHNICAL DIRECTOR 9 Sand Park Road * Suite 6 * Cedar Grove, NJ 07009 * 973.239.0100 * F: 973.239.0165 * www.artspower.org Technical Information Guide PLEASE FORWARD TO TECHNICAL DIRECTOR PLEASE NOTE: Approximately one to

More information

Aqua Turf International, Inc.

Aqua Turf International, Inc. Satellite Versus Decoder Control System During the irrigation design process a decision must be made whether to chose a satellite or decoder style control system. The decision must be made soon after the

More information

MicroPAVER TECHNOLOGY THAT WORKS FOR YOU

MicroPAVER TECHNOLOGY THAT WORKS FOR YOU MicroPAVER TECHNOLOGY THAT WORKS FOR YOU 39 TH ANNUAL ROCKY MOUNTAIN ASPHALT CONFERENCE & EQUIPMENT SHOW FEB 22, 2012 TED A. BORSTAD, P.E. BORSTAD CONSULTING SERVICES, LLC PAVEMENT MANAGEMENT CITIES COUNTIES

More information

Planning & Zoning Commission Meeting Date: June 18, 2012

Planning & Zoning Commission Meeting Date: June 18, 2012 Department of Planning and Research City of League City Planning & Zoning Commission Meeting Date: June 18, 2012 Requests Zoning Change Z12-04 (Lucas Construction) Rezone approximately 0.92 acres from

More information

Finding aid for the Lake Shore and Michigan Southern Railway collection Collection 192

Finding aid for the Lake Shore and Michigan Southern Railway collection Collection 192 Finding aid for the Lake Shore and Michigan Southern Railway collection Collection 192 Finding aid prepared by James B. Winslow This finding aid was produced using the Archivists' Toolkit May 07, 2013

More information

High-Definition, Standard-Definition Compatible Color Bar Signal

High-Definition, Standard-Definition Compatible Color Bar Signal Page 1 of 16 pages. January 21, 2002 PROPOSED RP 219 SMPTE RECOMMENDED PRACTICE For Television High-Definition, Standard-Definition Compatible Color Bar Signal 1. Scope This document specifies a color

More information

CATV Leakage Detection Flyovers with Pinpointing Capability

CATV Leakage Detection Flyovers with Pinpointing Capability CATV Leakage Detection Flyovers with Pinpointing Capability Cumulative Leakage Index (CLI) FCC and IC Compliancy Leakage Detection from Broadcast Analog and Digital Channels without Head End Injection

More information

Using the List of Approved Assemblies

Using the List of Approved Assemblies Using the List of Approved Assemblies Field Test Kits A u t u m n 2 0 0 4 The List of Approved Assemblies is one of the major benefits of Membership in the Foundation. The purpose of the List is to assist

More information

AUDIO VISUAL SERVICES Best Bites Competition

AUDIO VISUAL SERVICES Best Bites Competition REQUEST FOR QUOTE: AUDIO VISUAL SERVICES Best Bites Competition Quote: #19-214 RFQ Released: October 3, 2018 Deadline for Quotes: Monday, October 15, 2018 by 2:00 PM The Houston Livestock Show and Rodeo

More information

CITY OF TROUTDALE ADDRESS ATLAS APRIL

CITY OF TROUTDALE ADDRESS ATLAS APRIL CITY OF TROUTDALE ADDRESS ATLAS APRIL 211 PRINT DATE: September 9, 211, Public Works, GIS CITY OF TROUTDALE - MAP LEGEND TOWNSHIP AND RANGE LINE QUARTER-SECTION GRID 1 2 3 4 SECTION SECTION CENTER CORNER

More information

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company www.rstechserv.com Omni III Pan and Tilt Color Camera Modell 10-01610 OPERATIONS MANUAL Made in USA IMPORTANT SAFETY NOTICE

More information

Intelsat Maritime Solutions

Intelsat Maritime Solutions Intelsat Maritime Solutions One Flex for Maritime The Commercial Maritime Industy is Changing... Are You Ready? 69,500 Ships in Addressable Commercial Maritime VSAT market 60 Gbps High-throughput Satellite

More information

CITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE VIDEO TECHNICIAN, 6145

CITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE VIDEO TECHNICIAN, 6145 CITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE 1999 04-26-96 VIDEO TECHNICIAN, 6145 Summary of Duties: Operates municipal access equipment for City departments, City Council

More information

Chapter PUBLIC IMPROVEMENTS* * Cross References: Public ways and property, CBJ Code tit. 62. ARTICLE I. GENERALLY

Chapter PUBLIC IMPROVEMENTS* * Cross References: Public ways and property, CBJ Code tit. 62. ARTICLE I. GENERALLY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 Chapter 49.35 PUBLIC IMPROVEMENTS* * Cross

More information

DIVISION 800 INCIDENTAL CONSTRUCTION. 804 MAINTENANCE AND RESTORATION OF HAUL ROAD Record of Restoration and Maintenance of Haul Roads (Set) 804-1

DIVISION 800 INCIDENTAL CONSTRUCTION. 804 MAINTENANCE AND RESTORATION OF HAUL ROAD Record of Restoration and Maintenance of Haul Roads (Set) 804-1 DIVISION 800 INCIDENTAL CONSTRUCTION 801 MOBILIZATION Payment of Mobilization (DBE) 801-1 802 CONTRACTOR CONSTRUCTION STAKING Recapitulation of Construction Staking 802-1 Checking of Contractor Construction

More information

Region VII Levee Mapping Strategy. ASFPM Annual Conference Kansas City, MO May 4, 2017

Region VII Levee Mapping Strategy. ASFPM Annual Conference Kansas City, MO May 4, 2017 Region VII Levee Mapping Strategy ASFPM Annual Conference Kansas City, MO May 4, 2017 Welcome to the Jungle (of FEMA Levee Acronyms) LAMP PAL NV Zone X (shaded) SM 65.10 FAST NLD Risk MAP BFE SBI Zone

More information

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA TABLE OF CONTENTS Section Title Page 5901 GENERAL... 2 5902 DESIGN CRITERIA... 2 5902.1 Codes and Standards... 2 5902.2 Signal

More information

FOR LEASE 6759 HOLLYWOOD BLVD, LOS ANGELES, CA CHANDELIER PASSAGE UNDER CONSTRUCTION PART OF PLANNED HOLLYWOOD HOTEL RSF AVAILABLE

FOR LEASE 6759 HOLLYWOOD BLVD, LOS ANGELES, CA CHANDELIER PASSAGE UNDER CONSTRUCTION PART OF PLANNED HOLLYWOOD HOTEL RSF AVAILABLE FOR LEASE 6759 HOLLYWOOD BLVD, LOS ANGELES, CA 90028 UNDER CONSTRUCTION PART OF PLANNED HOLLYWOOD HOTEL 112 596 RSF AVAILABLE DENLEY INVESTMENT & MANAGEMENT JUSTIN RUBEL T 323.463.4100 DENLEYINVESTMENT.COM

More information

February Restoration of the Egyptian Theatre preserving our history for future generations

February Restoration of the Egyptian Theatre preserving our history for future generations Mayor Crystal Shoji February 2012 Restoration of the Egyptian Theatre preserving our history for future generations Council President Stephanie Kramer Gene Melton Jennifer Groth John Muenchrath Mike Vaughan

More information

City of Salem Address Number Range

City of Salem Address Number Range REVISED: Date: 12-10-2007 City of Salem Address Number Range No. Street Name E/O City Low City High Twp. Low Misc. 1 Adams Ave. E 720 988 O 815 985 2 Aetna St. E 380 868 O 195 843 3 Allen Rd. E 1210 1456

More information

PINE RIDGE ELEMENTARY

PINE RIDGE ELEMENTARY PINE RIDGE ELEMENTARY CALENDAR CHANGE PRESENTATION NOVEMBER 13, 2012 SCOTT SIEGFRIED, PH.D. ASSISTANT SUPERINTENDENT ssiegfried@cherrycreekschools.org AGENDA Provide information regarding the history,

More information

FIFTH ADDENDUM TO THE MEMORANDUM OF UNDERSTANDING Fiber Optic Network Agreement

FIFTH ADDENDUM TO THE MEMORANDUM OF UNDERSTANDING Fiber Optic Network Agreement ADDENDUM 5 FIFTH ADDENDUM TO THE MEMORANDUM OF UNDERSTANDING Fiber Optic Network Agreement Between The City of Lawrence, Kansas ( The City ) and Douglas County, Kansas ( The County ) Dated: December, 2015

More information

PEP-II Overview & Ramp Down Plan. J. Seeman DOE PEP-II Ramp Down-D&D Review August 6-7, 2007

PEP-II Overview & Ramp Down Plan. J. Seeman DOE PEP-II Ramp Down-D&D Review August 6-7, 2007 PEP-II Overview & Ramp Down Plan J. Seeman DOE PEP-II Ramp Down-D&D Review August 6-7, 2007 Topics Overview of the PEP-II Collider PEP-II turns off September 30, 2008. General list of components and buildings

More information

Bank of Louisiana 12/28/17 Owned Properties

Bank of Louisiana 12/28/17 Owned Properties Bank of Louisiana 12/28/17 Owned Properties Address Property Info List Price COMMERCIAL: 9290 Morrison Rd. Commercial Bldg.-2 story $695,000 New Orleans, LA 70126 11,386 sf lot 200 x 200 Residential Homes:

More information

MAT Practice (solutions) 1. Find an algebraic formula for a linear function that passes through the points ( 3, 7) and (6, 1).

MAT Practice (solutions) 1. Find an algebraic formula for a linear function that passes through the points ( 3, 7) and (6, 1). MAT 110 - Practice (solutions) 1. Find an algebraic formula for a linear function that passes through the points ( 3, 7) and (6, 1). Answer: y = 2 3 + 5 2. Let f(x) = 8x 120 (a) What is the y intercept

More information

SERVICE BULLETIN MANDATORY SB EFFECTIVITY SERIAL NUMBERS G36 (Bonanza) E-4076 thru E-4079, E-4084

SERVICE BULLETIN MANDATORY SB EFFECTIVITY SERIAL NUMBERS G36 (Bonanza) E-4076 thru E-4079, E-4084 Beechcraft SERVICE BULLETIN MANDATORY SB 34-4167 TITLE NAVIGATION - REPLACEMENT OF NONCONFORMING ALTIMETERS EFFECTIVITY MODEL SERIAL NUMBERS G36 (Bonanza) E-4076 thru E-4079, E-4084 G58 (Baron) TH-2435,

More information

King s Wharf Theatre

King s Wharf Theatre Alex Mustakas Artistic Director King s Wharf Theatre Rental Information Package 9 Jury Dr., Penetanguishene, ON, L9M 1G Box Office: 05-549-5555 Toll Free: 1-855-32-9866 kingswharftheatre.com For space

More information

Program Risks Risk Analysis Fallback Plans for the. John T. Seeman DOE PEP-II Operations Review April 26, 2006

Program Risks Risk Analysis Fallback Plans for the. John T. Seeman DOE PEP-II Operations Review April 26, 2006 Program Risks Risk Analysis Fallback Plans for the PEP-II B-FactoryB John T. Seeman DOE PEP-II Operations Review April 26, 2006 OPS Review Topics Are there any PEP-II program risks? Has the laboratory

More information

Audio-Visual Communications

Audio-Visual Communications Job Ready Assessment Blueprint Audio-Visual Communications Test Code: 2005 / Version: 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Photography Operate a still camera

More information

Why You Need a Nathan Or How to Avoid the Pitfalls of Synchrophasor Integration

Why You Need a Nathan Or How to Avoid the Pitfalls of Synchrophasor Integration 1 Why You Need a Nathan Or How to Avoid the Pitfalls of Synchrophasor Integration 2016 IEEE PES General Meeting Tutorial Use of Synchrophasors in Grid Operations Tuesday, July 19, 2016 Kevin D. Jones,

More information

AUDIO/VISUAL FOR WINE AUCTION & DINNER

AUDIO/VISUAL FOR WINE AUCTION & DINNER REQUEST FOR QUOTE: AUDIO/VISUAL FOR WINE AUCTION & DINNER Quote: #18-109 RFQ Released: October 23, 2017 Deadline for Quotes: Tuesday, October 31, 2017 by 10:00 a.m. and Rodeo (the HLSR ) was organized

More information

Underground Cable Diagnostic Testing Utilizing Partial Discharge Technique

Underground Cable Diagnostic Testing Utilizing Partial Discharge Technique Underground Cable Diagnostic Testing Utilizing Partial Discharge Technique (An Update to the April 29, 2001 Report) Potomac Electric Power Company Reliability Services (Asset Management) Mostafa Hassani,

More information

HEALTH AND SAFETY MANUAL

HEALTH AND SAFETY MANUAL HEALTH AND SAFETY MANUAL Title: Grounding Conductor Program Approved by: Greg Savoy Rev. 4/1/08 1 Purpose/Scope: The purpose of this program is to provide requirements to reduce employee potential for

More information

Environmental Impact Statement (EIS)/ Section 106 Public Meeting Level 1 Concept Screening. May 16, 2017

Environmental Impact Statement (EIS)/ Section 106 Public Meeting Level 1 Concept Screening. May 16, 2017 Environmental Impact Statement (EIS)/ Section 106 Public Meeting Level 1 Concept Screening May 16, 2017 Today s Agenda Project Overview Project Schedule Purpose and Need Level 1 Concept Screening Results

More information

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN ULTRA-TRAC APL A C O U S T I C P I P E L O C A T O R INSTRUCTION MANUAL Read and understand instructions before use. Patented MADE IN USA 851 Transport Drive Valparaiso, IN 46383-8432 Phone: 888 4SENSIT

More information

The Cleveland Circuit R.P.O.,

The Cleveland Circuit R.P.O., The Cleveland Circuit R.P.O., 1908-1919 This exhibit focuses on the postal markings of the Cleveland Circuit R.P.O., Cleveland's only streetcar postal route. The Cleveland Circuit concurrently utilized

More information

ATV-HD Project Executive Summary & Project Overview

ATV-HD Project Executive Summary & Project Overview ATV-HD Project Executive Summary & Project Overview Introduction & Statement of Need Since 2002, ATV has filmed nearly all of its shows in a small television studio attached to the station s offices in

More information

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER Updated: June 27, 2011 TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER TELEPHONE NUMBERS: General Administrative Offices 253.591.5890 Production Stage Manager 253.591.5898 Facsimile 253.591.2027

More information

Yaesu FT-950 and FT-450D with KPA/KAT500 Power Combo

Yaesu FT-950 and FT-450D with KPA/KAT500 Power Combo Yaesu FT-950 and FT-450D with KPA/KAT500 Power Combo The Yaesu FTdx1200, FT-450D and FT-950 series radio can be connected to the KAT/KPA500 combo using the Key signal available on the rear panel of the

More information

Modern mixed-use project: Restaurant & retail space available

Modern mixed-use project: Restaurant & retail space available Modern mixed-use project: Restaurant & retail space available 7141 7155 Santa Monica Blvd... For more information, please contact: 310.698.7804 626.233.0071 - MAKE A SPLASH - 310.698.7804 BRE# 01877785

More information

Dunfield Theatre Cambridge

Dunfield Theatre Cambridge Alex Mustakas Artistic Director Dunfield Theatre Rental Information Package Grand Ave. S.,, ON, NS L8 Office: 9--8000 Toll Free: -8-7-98 dunfieldtheatrecambridge.com For space availability, rental estimates,

More information

Appendix 6 St. Bernard Basin

Appendix 6 St. Bernard Basin Appendix 6 St. Bernard Basin The St. Bernard (STB) basin is defined by the protection system along the GIWW to the north, MRGO to the east, Caernarvon Canal to the south, and the Mississippi River and

More information

BELLEFONTE BOROUGH AUTHORITY MEETING MINUTES January 3, :00 p. m. 236 West Lamb Street, Bellefonte, PA www. bellefonte.

BELLEFONTE BOROUGH AUTHORITY MEETING MINUTES January 3, :00 p. m. 236 West Lamb Street, Bellefonte, PA www. bellefonte. CALL TO ORDER: BELLEFONTE BOROUGH AUTHORITY MEETING MINUTES January 3, 2018-6:00 p. m. 236 West Lamb Street, Bellefonte, PA 16823 www. bellefonte.net The meeting of the January 3, 2018 Bellefonte Borough

More information

City of Grand Island

City of Grand Island City of Grand Island Tuesday, September 11, 2007 Council Session Item G14 #2007-223 - Approving Contract with AVI Systems for Master Control & Studio Relocation Staff Contact: Wendy Meyer-Jerke City of

More information

DRAFT MINUTES PUBLIC SERVICE COMMITTEE WADSWORTH CITY COUNCIL Administrative Conference Room March 14, :30 P.M.

DRAFT MINUTES PUBLIC SERVICE COMMITTEE WADSWORTH CITY COUNCIL Administrative Conference Room March 14, :30 P.M. DRAFT MINUTES PUBLIC SERVICE COMMITTEE WADSWORTH CITY COUNCIL Administrative Conference Room March 14, 2017 5:30 P.M. COMMITTEE MEMBERS PRESENT Bruce Darlington, Chair Ralph Copley and Mr. Sharkey COMMISSION

More information

MINUTES. Greg Nelson, Chairperson; Mark Ozbun, Treasurer; Dean Fortin, Secretary, Terry Dean, Marilyn Anderson

MINUTES. Greg Nelson, Chairperson; Mark Ozbun, Treasurer; Dean Fortin, Secretary, Terry Dean, Marilyn Anderson ATTENDANCE Board Members: NWCM: Condo Owners: OPENING: APPROVAL OF Greg Nelson, Chairperson; Mark Ozbun, Treasurer; Dean Fortin, Secretary, Terry Dean, Marilyn Anderson Martha and Tim Craven Greg Nelson

More information

IBAK Made in Germany. IBAK Helmut Hunger GmbH & Co. KG Wehdenweg Kiel Germany Tel. +49 (0) Fax +49 (0)

IBAK Made in Germany. IBAK Helmut Hunger GmbH & Co. KG Wehdenweg Kiel Germany Tel. +49 (0) Fax +49 (0) IBAK Made in Germany All IBAK products have one thing in common: They are "made in Germany". All system components are developed, produced, installed and tested by IBAK. Due to their high quality standard,

More information

TABLE OF CONTENTS [LETTER AGREEMENT]

TABLE OF CONTENTS [LETTER AGREEMENT] The Table of Contents, the footnotes, and the paragraph and subparagraph headings shown in brackets and bold print, are NOT part of the Document, but have been added for the convenience of the reader.

More information

USB-TG124A Tracking Generator User Manual

USB-TG124A Tracking Generator User Manual USB-TG124A Tracking Generator User Manual Signal Hound USB-TG124A User Manual 2017, Signal Hound, Inc. 35707 NE 86th Ave La Center, WA 98629 USA Phone 360.263.5006 Fax 360.263.5007 This information is

More information

Attachment 2 Wastewater

Attachment 2 Wastewater Attachment 2 Wastewater 1 Overview 11 Objective The objective of this attachment is to set the minimum controls for planning and implementing flow isolation / flow management (FIFM) to ensure the safety

More information

WATER/RECYCLED FIFM Complex Works Assessment Sheet

WATER/RECYCLED FIFM Complex Works Assessment Sheet WATER/RECYCLED FIFM Complex Works Assessment Sheet Project Title / Name MAXIMO number: Case No: Criteria to identify complex FIFM for referral to Area Teams Comments 1. Is entry into a hydraulic asset

More information

MINNEHAHA COUNTY ON-SITE WASTEWATER TREATMENT SITE EVALUATION WORKSHEET Form #1. Land Owner. Legal Description

MINNEHAHA COUNTY ON-SITE WASTEWATER TREATMENT SITE EVALUATION WORKSHEET Form #1. Land Owner. Legal Description MINNEHAHA COUNTY ON-SITE WASTE TREATMENT SITE EVALUATION WORKSHEET Form #1 Land Owner Legal Description Type of Structure (check one): Residence Commercial Industrial Accessory Building Other If Residence:

More information

2211 N. Austin Ave. Georgetown, TX x7184

2211 N. Austin Ave. Georgetown, TX x7184 2211 N. Austin Ave. Georgetown, TX 78626 512.943.5100 x7184 Smithj9@georgetownisd.org poteetb@georgetownisd.org leachj@georgetownisd.org March 22, 2017 Dear Colleagues: It is the pleasure of the Georgetown

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, F: (979) 690-0440 E-mail : globalw@globalw.com FC220 Flow Monitor

More information

Any feature not specifically noted as supported is not supported.

Any feature not specifically noted as supported is not supported. Manufacturer: ELAN Integration Note Model Number(s): EL-4KM-VW44 (Device Ver 2.20; Web Module Ver 6.23) Minimum Core Module Version: Document Revision Date: 8.1.395 5/11/2017 OVERVIEW AND SUPPORTED FEATURES

More information

Progress of Management Reforms and Activities in 2 nd Half

Progress of Management Reforms and Activities in 2 nd Half Progress of Management Reforms and Activities in 2 nd Half Kunihiko Sato President 1. Progress of Management Reforms 1 1 Approach to Management Reforms Progress in line with plans 1. Change in business

More information

Mini LED Pin Spot Light Model: PLS00571

Mini LED Pin Spot Light Model: PLS00571 Mini LED Pin Spot Light Model: PLS00571 1 Please read these instructions carefully before use and retain for future reference. IMPORTANT SAFETY INFORMATION When using electrical appliances basic safety

More information

Home-Turf Report for 5399 Midlothian Turnpike, Crestwood, IL

Home-Turf Report for 5399 Midlothian Turnpike, Crestwood, IL Home-Turf Report for 5399 Midlothian Turnpike, Crestwood, IL Nearest Public Library: Nearest Hospital: Oak Forest Hospital of Cook County, 15900 S Cicero Ave, 2.4mi S Nearest Fire 0.8mi NE Nearest Restaurant

More information

Application Note: Using the Turner Designs Model 10-AU Fluorometer to Perform Flow Measurements in Sanitary Sewers by Dye Dilution

Application Note: Using the Turner Designs Model 10-AU Fluorometer to Perform Flow Measurements in Sanitary Sewers by Dye Dilution Instrument set-up: Model 10-AU Digital Fluorometer equipped with the 13 mm x 100 mm cuvette holder; and a 10-056/10-056R (546 nm) Excitation Filter, a 10-052/10-052R (>570 nm) Emission Filter, 10-053/10-053R

More information

Hollywood & Highland Tour

Hollywood & Highland Tour The Real Los Angeles Tours: Self Guided Tour Hollywood & Highland Tour Hollywood High School Once upon a time (only around 1900) where you re now standing was open land in all directions. That s one of

More information

Incorrect Temperature Measurements: The Importance of Transmissivity and IR Viewing Windows

Incorrect Temperature Measurements: The Importance of Transmissivity and IR Viewing Windows Incorrect Temperature Measurements: The Importance of Transmissivity and IR Viewing Windows Abstract IR viewing windows save lives. Most Thermographers today are thankful to perform their scans without

More information

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company www.rstechserv.com 1315 Controller OPERATIONS MANUAL Made in the USA Table Of Contents: Page 3 Page 5 Page 6 Page 7 Page

More information

6MSD Weekly Scheduling Meeting. 1:30, MCC Conference Room

6MSD Weekly Scheduling Meeting. 1:30, MCC Conference Room 6MSD Weekly Scheduling Meeting Wednesday @ 1:30, MCC Conference Room July 6, 2011 1) Glance Back and 2-Week Look Ahead (F. Pilat)... 10 mins 2) PMI Report (P. Collins)... 5 mins 3) Critical Path Service

More information

Advances in practical applicability of DTS in sewer systems

Advances in practical applicability of DTS in sewer systems Advances in practical applicability of DTS in sewer systems Rémy Schilperoort 1, Cornelis de Haan 1, Erik Liefting 1, Henk Nijhof 2, Arjo Hof 3, Christophe Meijer 4 and Jeroen Langeveld 1,5 1 Partners4UrbanWater,

More information

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment

More information

CORRIGENDUM. Date /ENGG/ELE/ Tender NIT number:

CORRIGENDUM. Date /ENGG/ELE/ Tender NIT number: CORRIGENDUM Date-24-10-2018 Tender NIT number: Name of Wk : Sub: 2598/ENGG/ELE/2018-19 National competitive Bidding (NCB) f Conceptualizing, Designing, Supplying, Installing, Testing and Commissioning

More information

List Of Upcoming Hollywood Movies

List Of Upcoming Hollywood Movies We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with list of upcoming hollywood

More information

AMPHENOL RF ENABLES THE INTERNET OF THINGS

AMPHENOL RF ENABLES THE INTERNET OF THINGS AMPHENOL RF ENABLES THE INTERNET OF THINGS Background The Internet of Things (IoT) is delivering the promises of greater efficiency, improved production, enhanced and new services, and deeper levels of

More information

DIGGERS HOTLINE. Midwest Fiber Networks, LLC. CALL : (414) OR TOLL FREE (800) MIDWESTFIBERNETWORKS

DIGGERS HOTLINE. Midwest Fiber Networks, LLC. CALL : (414) OR TOLL FREE (800) MIDWESTFIBERNETWORKS 24.75' 24.75' 24.75' 70' RESERVED 24.75' 47.08' 10' NTH 80TH 70' 30' 6' 14' 6' ROAD RESERVED PUBLIC UTILITY EASEMENT 33' 80' 52' BRADLEY ROAD 6' 30' INGRESS & EGRESS 20' 20' AVENUE BRADLEY ROAD 52' NO

More information

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes Introduction Embedded design and especially design work utilizing low speed serial signaling is one of the fastest growing areas of digital

More information

Master of Entertainment Industry Management

Master of Entertainment Industry Management Master of Entertainment Industry Management Course Information Description Production Management Course Number: 93.852 Credit Units: 6 Fall 2018 Saturdays, 10:00 AM 1:00 PM Instructors: Ed Lammi (Ed_Lammi@spe.sony.com)

More information

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video

More information

2 Connect your video source

2 Connect your video source PowerLite 6110i 2 Connect your video source Quick Setup Choose a location The projector supports 4 viewing setups. Choose the best one for your environment. If you install the projector in a rear or overhead

More information

Concept of Operations (CONOPS)

Concept of Operations (CONOPS) PRODUCT 0-6873-P1 TxDOT PROJECT NUMBER 0-6873 Concept of Operations (CONOPS) Jorge A. Prozzi Christian Claudel Andre Smit Praveen Pasupathy Hao Liu Ambika Verma June 2016; Published March 2017 http://library.ctr.utexas.edu/ctr-publications/0-6873-p1.pdf

More information