DATA SHEET ML210 ML210_IT_EN_DS017REV12_IS

Size: px
Start display at page:

Download "DATA SHEET ML210 ML210_IT_EN_DS017REV12_IS"

Transcription

1 DATA SHEET ML210

2

3 INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 TECHNICAL DATA 2 ACCURACY 3 OVERALL DIMENSION 4 VISUALIZATION PAGES 5 ELECTRICAL CONNECTIONS 6 TABELLA DELLE PRECISIONI 10 ML210/MS2500: MI-001 DETAILS 11 ML210/MS2500: MI-004 DETAILS 12 HOW TO ORDER 13

4 1 di 15

5 TECHNICAL DATA Suitable For Minimum conductivity Altitude Ambient Temperature OVERALL FEATURES All the ISOMAG sensors 5 µs/cm -200 m up to 5000 m C / F - Aluminium housing C / F - Panel mounting housing Humidity Range 0 100% (IP65 -IP 67) 0-90% (IP40) without condensation, for panel mounting housing (without transparent frontal cover IP 65) STANDARD FEATURES Wall/Compact: Painted Aluminium die casting Housing materials Panel version: NORYL UL 94 V-0 black IP 67 Aluminium housing Protection Rate IP65/IP40 Panel version Power Supply/Consumption V~ (25VA) Hz Cable Gland N 6 cable gland PG 11 Data Logger 32 values + 64 alarm events Full scale value 0,4 10m/s Digital Outputs N 2 Programmable function (Pulses, alarms) 1250 Hz, 100mA, 40 Vdc Protocols ETP Dig. Input N 1, programmable function (Totalizer reset) Data Storage Eeprom values storing system in case of power failure Galvanic Isolation All the inputs/outputs are galvanically isolated from power supply up to 500 V Programming Plug In Protected plug in for the connection to PC or hand terminal Bi-Directional Yes Dual Range Yes Diagnostic Funct. Yes Empty Pipe Detect. Yes Batch Function Yes CE Certification Yes 2 di 15

6 OPTIONAL FEATURES (CHECK HOW TO ORDER, AT LAST PAGE, FOR MORE DETAILS) Housing materials Version Protection Rate Conn. Sensor Cable Power Supply/Consumption Wall/Compact: AISI304 Compact Separate IP 68 CABLE C015 - C016 for separate version CABLE C014 for separate version with pre-amplifier LCD Display Graphic display 128x64 pixels back light,3 programming keys Pulses/ Alarm Outputs Current Output Communication port Protocols Certification Measurements tolerance Accuracy (whole system converter+sensor) 18-45V~ (25 VA) 44-66Hz V (20W); 10-35V (20W) N 2, 1250 Hz, 100mA, 40 Vdc (12,5 KHz Opt.) Relais N 1, 0/4 20mA RL=1000Ω (+1 Opt.) RS 485 RS232 Profibus DP/HART/Modbus MI-001 MI-004 ACCURACY Flow rate (volume) = ±0,05% v.l. Out 4/20 ma = ± 0,08 % v.l. Frequency Out = ± 0,08% v.l. See table below 3 di 15

7 OVERALL DIMENSION Compact version 170 Sensor Separate (wall) version Panel version TERMINAL BLOCK 4 di 15

8 VISUALIZATION PAGES Flowrate and totalizes visualization Flowrate, speed values and graph Flowrate value and Full scale % graph Flowrate graph Flowrate value with currency function enabled Different visualization possibilities with the simple press of a key 5 di 15

9 ELECTRICAL CONNECTIONS Terminal block: compact/separate version ELECTRODES E1 E2 C SC INPUT RS mA + - B A + - OUT3 E C OUT3 CTS RD TD SG SC B1 B2 SH + CE E C E COILS 24V OUT1 OUT2 24V INP2 C E OUT4 SH mA Terminal block: panel mounting version Mors. M3 Morsettiera M Morsettiera M1 ON/OFF standard output (out1) 18 (out2) OUT4 C NC NO OUT3 24V OUT2 OUT1 24V COILS C NC NO E C E CE SH B2 B1 SC SH mA + A B - + SC C E2 E1 RS485 INPUT ELECTRODES ON/OFF high frequency output (out1) 19 (out2) 29 4/20 ma output +24V Internal I ma +24V Common 9(+) 10(-) ON/OFF input 10KΩ 5(+) 5/33Vdc (ON) 0/1.5Vdc (OFF) 6(+) 6 di 15

10 Insert sensor ND (0-3000mm) Sensor calibration data, visualized on sensor s label Type of sensor: Enter the first two characters of the sensor serial number Position for insertion sensors: 0=1/8DN, 1=1/2DN, 2=7/8DN 1.5 Factory parameters automatically calculated (ONLY for insertion sensors) 1.6 Length of the cable connecting the sensor to the converter 1.7 Enables the empty pipe detection feature 1.8* Electrodes cleaning 1.9* Value of empty pipe sensibility detection 1.10* Enables the automatic procedure of zero calibration 2.1* Full scale value set for range N.1 2.2* Full scale value set for range N.2 2.3* Unit of measure and number of decimal place 2.4* Pulse value on channel 1 2.5* Pulse value on channel 2 2.6* Duration of the pulse generated on channel 1 2.7* Duration of the pulse generated on channel Full scale freq. for channel 1 (0.1Hz Hz) (0.1Hz-10000Hz with opt. module) 2.9 Full scale freq. for channel 2 (0.1Hz Hz) (0.1Hz-10000Hz with opt. module) 2.10 Enable/disable the selection of mass units on full scale set 2.11 Specific gravity set in kg/dm³ 3.1* Measure filter 3.2 Low flow cut off threshold: 0-25% of full scale value 3.3 Enable every hour an internal cycle of calibration. Measurement stopped for 8-15 sec. 3.4* Automatic change of measurement range 4.1 Maximum value alarm set for direct flow rate 4.2 Maximum value alarm set for reverse flow rate 4.3 Minimum value alarm set for direct flow rate 4.4 Minimum value alarm set for reverse flow rate 4.5 Hysteresis threshold set for the minimum and maximum flow rate alarms 4.6* Current output value in case of failure 4.7* Frequency output value in case of failure 4.8* Batch safety timer 5.1* Total direct (positive) flow totalizers reset enable 5.2* Partial direct (positive) flow totalizers reset enable 5.3* Total reverse (negative) flow totalizers reset enable 5.4* Partial reverse (negative) flow totalizers reset enable 5.5 Reset totalizers of pulse from digital input (see page 14) 5.6 Totalizers counting lock command (see page 14) 5.7* Block measures command 5.8* Autozero calibration external command 5.9 Range change external command (see function 3.5) 5.10 Batch start/stop external command (see batch functions) 5.11*Functions assigned to input 2 7 di 15

11 6.1* Output 1 functions 6.2* Output 2 functions 6.3* Output 3 functions 6.4* Output 4 functions 6.5* Choice of the function and the range of current output n.1 6.6* Choice of the function and the range of current output n Choice of the communication protocol for the IF2 device 7.2 Choice of the communication protocol for the RS232 port 7.3 Speed of the RS485 output (possible choices: 4800, 9600, 19200, bps) 7.4 Speed of the RS232 output (possible choices: 4800, 9600, 19200, bps) 7.5 Print function enable (optional) 7.6 Print of the performed batch 7.7 Print of the data process on regular intervals 7.8 Print of events 7.9 Instrument answer delay 7.10 RS485 parity 7.11 Address value of converter (range 0-255) 7.12 Address of a further converter connected like a terminal 7.13 Start remote connection to the terminal. Connection interrupted after 10sec. of inactivity 8.1 Choice of the language: EN= English, IT=italian, FR= French, SP= Spanish, DE=German 8.2 Display updating frequency: Hz 8.3* Display contrast 8.4 Partial totalizer visualization (with batch enable the function is always on) 8.5 Date and time visualization with data logger enable 8.6 Quick start menu visualization 8.7 Enable the page of net totalizer (difference between direct and reverse) 8.8 Visualizes the values of the partial totalizers in the unit of selected currency 8.9 Choice of the numbers of decimals for the visualization currency value: From 0 to * Value of conversion/currency for direct totalizer 8.11* Value of conversion/currency for reverse totalizer 8.12 Reset processor of the display (useful in case of particular badly operations of the display) 8.13* Total direct (positive) flow totalizer reset 8.14* Partial direct (positive) flow totalizer reset 8.15* Total reverse (negative) flow totalizer reset 8.16* Partial reverse (negative) flow totalizer reset 9.1* Date and time set 9.2 Automatic data logger enable 9.3 Interval time for the data logging function: 1, 2, 3, 6, 8, 12, 24, 48 hours 9.4 Displaying of the data stored in the data logger 9.5 Displaying of the last 64 alarms stored in the data logger 9.6 Visualization function of minimum and maximum peak of flow rate 9.7 Logged data cancel function 9.8 Reset all alarm events 9.9 Reset all minimum and maximum peak of flow rate stored 8 di 15

12 10.1* Calibration of the converter 10.2* Autotest converter 10.3* Flow rate simulation enabling 10.4 Firmware revision/version 11.1 Level 2 access code enter 11.2 Load factory data pre-set 11.3 Load user data saved 11.4 Save user data 11.5 Ignore the calibration error during the switch on test 11.6 Ks coefficient (only for service purposes) Menu 12: batch function 12.1* Number of batch cycles to define the value of compensation. Value 0=OFF 12.2* % limit of compensation threshold 12.3* Compensation value 12.4* Prebatch value 12.5* Auto-batch 12.6* Automatic selection of batch formula 12.7* Static consent of batch 9 di 15

13 TABELLA DELLE PRECISIONI e % Fullbore sensor Tipico profilo dell errore ( puramente rappresentativo) 0,1 m/s 0,33 ft/sec 0,5 m/s 1,64 ft/sec speed 0,5 m/s (1,64 ft/s) e = +/- A % (reading value) speed < 0,5 m/s (1,64 ft/s) e = +/- (B/V) % (reading value) minimum flow (l/s): DN x DN x 0,008/1000( DN expressed in mm ) where: e = ACCURACY 5,0 m/s 16,4 ft/sec V = WORKING SPEED 10,0 m/s 32,8 ft/sec SPEED (A and B values: see below table according to CONVERTER model) MS501/MS1000/MS2410/MS2500 MS 600 MS5000 A B(m/s) B(ft/s) A B(m/s) B(ft/s) A B(m/s) B(ft/s) 0,2 0,1 0,33 0,4 0,2 0, ,28 Insertion sensors See sensors DATA SHEET Reference conditions below and as per internal testing procedures: Constant flow rate during the test Pressure: >30 Kpa Flow condition : fully developed flow profile Zero stability +/- 0,005 % 10 di 15

14 ML210/MS2500: MI-001 DETAILS The sensor s diameters listed below, coupled with ML210, ML110 and 255 are certified according to European Directive 2004/22CE category MI-001 (OIML R49) SENSOR mm SIZE inch 1 1 ¼ 1 ½ 2 2 ½ Q1 m³/h Q2 m³/h Q3 m³/h Q4 m³/h R Q3/Q1 160 (ML210-ML110) R Q3/Q1 from 100 up to 400 (ML255) Q3 allowed range: MI-001 ALLOWABLE RANGE /m 3 h -1 /dm 3 s -1 /m 3 h -1 /dm 3 s -1 /m 3 h -1 /dm 3 s -1 /m 3 h -1 /dm 3 s -1 /m 3 h -1 /dm 3 s ,278 1,6 0,444 2,5 0, ,111 6,3 1, , , , , , , , , , , , , , R (= Q3/Q1) allowed range 10 12, , Q2/Q1=1,6 Q4/Q3=1, OIML R49 ACCURACY CLASS 2 (Maximum permissible Error) MPE / % Q1 Q2 Q3 Q (Q3<100m³/h) (0,1<T<30 C) (Q3<100m³/h) (T>30 C) OIML R49-1:2006 (E) MS2500 profilo tipico curva errori 11 di 15

15 ML210/MS2500: MI-004 DETAILS The sensor s diameters listed below, coupled with ML210 and ML110, are certified according to European Directive 2004/22CE category MI-004 Sensor ND mm inch 1 1 ¼ 1 ½ 2 2 ½ q i m³/h ,1 q p m³/h q p (10m/s) m³/h q p /q i Sensor ND mm inch 1 1 ¼ 1 ½ 2 2 ½ qi m³/h ,1 qp m³/h qp (5m/s) m³/h q p /q i Sensor ND mm inch 1 1 ¼ 1 ½ 2 2 ½ qi m³/h ,1 qp m³/h qp (2;5m/s) m³/h q p /q i Sensor ND mm inch 1 1 ¼ 1 ½ 2 2 ½ qi m³/h ,1 qp m³/h qp (1,0m/s) m³/h q p /q i MPE / % 1 qi 0-1 0,1qp qp q/q p % Maximum permitted error Typical MS2500's accuracy profile 12 di 15

16 HOW TO ORDER CODE EXAMPLE Display A A B C WITHOUT DISLAY ( BLIND EXECUTION) Graphic LCD WSTN-GREEN -back light display, point matrix 128 x 64, 8 line each of 16 characters and 3 keys Graphic LCD WSTN-WHITE -back light display, point matrix 128 x 64, 8 line each of 16 characters and 3 keys Housing material / Protection rate 0 Painted aluminum die casting, protection rate IP67 1 AISI304 Stainless Steel housing, protection rate IP67 ( DISPLAY NOT ROTABLE ) 0 2 NORYL UL 94 V-0 black ( ONLY F VERSION ) IP 40 3 NORYL UL 94 V-0 BLACK ( ONLY F VERSION )+TRANSPARENT FRONTAL COVER IP 65 4 Painted aluminum die casting, protection rate IPXX, preset for CUSTOMER CABLE GLAND (Total Dim. Max available 105 x 52 mm) 9 Painted aluminum die casting, protection rate IP68 (special version CONTACT THE FACTORY) Version A Compact version with sensor MS... (liquid maximum temperature 100 C) A Power supply 1 Analogue output A Serial Interface B D F Separate version ( CABLE C015-C016 OR C014 with preamp. ) for wall monting, complete with mounting accessories in Aluminum (painted RAL6028) Separate version ( CABLE C015-C016 OR C014 with preamp. ) for wall monting, complete with mounting accessories in AISI304 Separate version ( CABLE C015-C016 OR C014 with preamp. ) for FRONT PANEL mounting according DIN 43700(72x144) complete with mounting accessories; AVAILABLE ONLY FOR HOUSING MATERIALS OPTIONS 2 AND 3 ( SEE ABOVE ) 1 Power supply : V Hz 2 Power supply : VAC-DC / Hz 3 Power supply : V dc 9 Power supply : other A B Without Analogue output Analogue output 0/4...20/22 ma 1 Without RS485 Serial Interface 1 Additional module 2 RS485 Serial Interface 3 Modbus protocol over RS 485 interface A A C D E F G P T Without additional module ME200; n. 2 additional ON / OFF programmable output + 1 ON/OFF INPUT ME201; n. 2 additional ON / OFF programmable output (one of them at 10 KHz frequency)+ 1 ON/OFF INPUT ME202; additionals 0/4 20 ma + n.2 ON / OFF programmable output + 1 ON/OFF INPUT ME203; n. 1 RS232 serial interface + n.2 additional ON / OFF programmable output + 1 ON/OFF INPUT ME204; n. 1 RS232 serial interface + additionals 0/4 20 ma + n.2 ON / OFF program. output + 1 ON/OFF INPUT ME205; n. 2 relè output (each with 1 NO contact + 1 NC contact, 2A - 60 Vca, 60W 125 VA) ME207; n. 2 relè output (each with 1 NO contact + 1 NC contact, 2A Vca, 60W 125 VA) H ME 100 ; Profibus DP communication module ( NOT POSSIBLE IF HOUSING MATERIAL 2 AND 3) 1 BlueTooth INTERFACE 2 ME101 - HART PROTOCOL OUT ( NOT POSSIBLE IF HOUSING MATERIAL 2 AND 3) Hart certified. Z Other 13 di 15

17 Special Features 0 NONE 0 1 WITH ANTICONDENSE CAP 2 n 4 CABLE GLAND 1/2 NPT - IP68 - Nickel plated brass CODE ( CABLE 6-12 mm ) 3 PAINT RAL9005 (BLACK) ML210-A0A1A1A0 (Complete code example for order) 14 di 15

18 ISOIL INDUSTRIA S.p.A. HEAD OFFICE SERVICE Via Fratelli Gracchi, Cinisello Balsamo (MI) Tel Fax If you want to find the complete list of our distributors access at the following link: If you want to find the complete list of our distributors access at the following link: BEFORE returning any material, please contact our SERVICE at the adress: Due to the constant technical development and improvement of its products, the manufacturer reserves the right to make changes and/or modify the information contained in this document without notice. AZIENDA CON SISTEMA DI GESTIONE QUALITA CERTIFICATO DA DNV GL

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G ISOMAG THE FRIENDLY MAG METER Converter EX CONVERTER Hazardous area Categories according to 94/9/CE Directive Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G Gas, mists or vapours Zone

More information

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS DATA SHEET MS 3780 INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 OPTIONAL FEATURES 2 TECHNICAL DATA 2 OVERALL DIMENSIONS 3 LAYOUT 4 INSTALLATION 5 INSTALLATION RECOMMENDATIONS 6 SENSOR GROUNDING 7 SENSOR

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

SITRANS F M. Transmitter MAG 5000/6000 4/33

SITRANS F M. Transmitter MAG 5000/6000 4/33 Siemens AG 2011 Flow Measurement Overview Design The transmitter is designed as either IP67 NEMA X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

FLOMAT Electromagnetic Insertion Flowmeter

FLOMAT Electromagnetic Insertion Flowmeter LOMAT Electromagnetic Insertion lowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction or use in large diameter pipes or open channels as an

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

Capacitance Level Measurement Electronic insert FEC 12

Capacitance Level Measurement Electronic insert FEC 12 Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview Siemens AG 2011 Flow Measurement Overview Design The transmitter is designed as either IP67 NEMA X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack

More information

The measurements are stored in non-volatile memory, which retains data even when the power down.

The measurements are stored in non-volatile memory, which retains data even when the power down. Data Sheet: DSTAR.545.R1.ENG www.aep.it FAST Professional Handheld Indicator Dynamicstar is an professional indicator, ergonomic, extremely versatile and simple to use for measures FORCE, WEIGHT, PRESSURE,

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN Main features Ranges: from: 0...1000 to 0...5000 bar Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc

More information

AF-300 E11 Adjustable Frequency Drive

AF-300 E11 Adjustable Frequency Drive AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed

More information

Standard RS232 RS ma

Standard RS232 RS ma 1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision

More information

Preset counters, electronic

Preset counters, electronic The multifunction preset counters Codix 923 / 924 can be used universally. These preset pulse counters, tachometers or preset timers with up to 6 presets can solve a wide variety of control and monitoring

More information

DCP100 Digital Control Programmer Specifications

DCP100 Digital Control Programmer Specifications DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,

More information

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR 2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR Power supply It is based upon the latest switch mode power supply technology, offering size reduction (i.e. 19 rack, 3U power supply), good

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

Digital differential Pressure switch Model DPS Instruction manual

Digital differential Pressure switch Model DPS Instruction manual Digital differential Pressure switch Model DPS Instruction manual DPSeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054 Nova

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85  Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter 3 YEAR SENSOR WARRANTY 5.4 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. General MJK Oxix s are designed

More information

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES CET DOUBLE COUNTER WITH TWO THRESHOLDS Type: LBM62CD 6 DIGITS DOUBLE DIGITAL COUNTER WITH TWO SEPARATE COUNT IMPUTS LBM62CD counter is a double counter with two separate counters. Each counter s input

More information

LD OEM/LD PDS/LD PeCo

LD OEM/LD PDS/LD PeCo LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class

More information

Sensopress LCD Special English

Sensopress LCD Special English Sensopress LCD Special English edition 2-09/2004 - code 5878 1/16 Sensopress LCD with sensor Power Supply Voltage 117 V~ 50 60 Hz 230V~ 50 60 Hz Code TSL00X0100 TSL00Y0100 Consumption 5,5 VA Display LCD

More information

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter Data Sheet 3 YE A SEN R WAR SOR RAN TY 5.4 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL:

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids Flowmeters Instrumentation for fluids Series FLOMT FLOMT Electromagnetic Insertion Flowmeter: Introduction For use in large diameter pipes or open channels as an economical solution for liquid metering.

More information

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly The Codix 923/924 can be used universally. As a preset pulse counter, tachometer or preset timer with up to 6 presets it is able to solve a very wide range of control and monitoring tasks in every application.

More information

INSTALLATION & USER GUIDE

INSTALLATION & USER GUIDE INSTALLATION & USER GUIDE Digidim 458 8-Channel Dimmer STEP 1 Assemble Dimmer Unit STEP 2 Mount Dimmer Chassis STEP 3 Electrical Installation STEP 4 Attach Module and Make Connections STEP 5 Replace Cover

More information

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 LINEAR ACTUATORS Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for

More information

ELE C TRO MAG N E T I C FLO W M E T E RS

ELE C TRO MAG N E T I C FLO W M E T E RS ELE C TRO MAG N E T I C FLO W M E T E RS PROVEN AND RELIABLE FLOW MEASUREMENT 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without moving parts, straight through flow

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal Operating and installation manual Programmable differential pressure transmitter for pressure or flow measurement and control. MF-PFT Instruction : Mi-202gb_060907 NOTE! Read the entire instruction carefully

More information

Eaton Durant. Counters, process instruments and hour meters.

Eaton Durant. Counters, process instruments and hour meters. Alltid Always tillgänglig available - Alltid öppen! - Always open! Electronic totalizers, LCD display - 1/32 DIN 24x mm Eaton Durant Catalogue Weight Type number kg/each Totalizer, add/subtract, NPN/PNP

More information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications ABB MEASUREMENT & ANALYTICS DATA SHEET AZ00 series Zirconia oxygen analyzer for small boiler applications AZ 00 SE RIE S Z I RCON I A OX YG EN ANALY ZE R FOR SMALL BOILE R APPLIC ATIONS DS/AZ00-E N RE

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical

More information

EVENT INPUT/OUTPUT MODULE [PUME]

EVENT INPUT/OUTPUT MODULE [PUME] PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm

More information

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,

More information

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing ADVANCED ultrasonic sensors with analog output Dimensioned drawing en 07-2017/02 50124880 4...20 ma 0...10 V 25 400mm 150 1300mm 15-30 V DC We reserve the right to make changes PAL_DMU418BX3LTVC_en_50124880.fm

More information

Digital differential pressure controller Model DPD Instruction manual

Digital differential pressure controller Model DPD Instruction manual Digital differential pressure controller Model DPD Instruction manual DPDeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054

More information

ADJUSTABLE SPEED DRIVES. nc1 Drive

ADJUSTABLE SPEED DRIVES. nc1 Drive ADJUSTABLE SPEED DRIVES nc1 Drive Ultra-Compact Sub-Micro Drive The nc1 is a sub-micro, or nano-sized drive with a full range of features to meet the needs of nearly any user. The nc1 is designed to be

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Data Acquisition Networks. Installing and Configuring the DM01 Hardware Data Acquisition Networks Installing and Configuring the DM Hardware What is the DM? D.A.N developed the DM-2 to capture 6 analogue measurements and pulse count in the field. The Average, Maximum and Minimum

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

+GF+ SIGNET 8860 Dual Channel Conductivity/Resistivity Controller

+GF+ SIGNET 8860 Dual Channel Conductivity/Resistivity Controller OUTPUT OPTION RELAY 3,4 OPEN COLL 3,4 TEMP 1 SGNL 1 TEMP 2 SGNL 2 - OPEN COLL 4 Æ L ENGLISH 3-8860.090 A-7/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions

More information

Time meter electronic

Time meter electronic Time meter electronic Universal with dual functions CODIX 52U 000000 0... 30V DIN 24 x 48 Power supply dimensions -0 +50 65 Wide temperature range High IP protection rating Powerful Fast count input Input

More information

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1. Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options

More information

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type. INSTRUCTI MANUAL Sensor High-performance Digital Display DP-1 Series Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model KBF 115 Constant climate chambers with large temperature / humidity range Model KBF 115 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

Page 1 of 7 Preselection and multifunction up/down counters 48x48 - CPT4 - Electronic multifunction counters CPT4 - LCD - 6 x 9 mm digits Selling points of the range Preselection counter, Tachometer, Timer,

More information

dissolved oxygen transmitter

dissolved oxygen transmitter dissolved oxygen transmitter SENSOR with MINIMAL maintenance 2 The Oxix transmitter is a unique dissolved oxygen measurement system with an optical sensor that communicates with a state-ofthe-art electronic

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85   Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

Capacitance Limit Detection nivotester FTC 420/421/422

Capacitance Limit Detection nivotester FTC 420/421/422 Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

Mechanical flow switch for On/Off control

Mechanical flow switch for On/Off control Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending)

More information

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure

More information

TABLE OF CONTENTS. Instructions:

TABLE OF CONTENTS. Instructions: TABLE OF CONTENTS Instructions: 1 Overview 1 2 Main technical parameters 1 3 Display and keyboard 2 3.1 Display Window 2 3.2 Indicator 4 4. Operation 4 4.1 Power 4 4.2 Zero 4 Modified 4 4.3 Modified 4

More information

Hour Meters / Timers, electronic

Hour Meters / Timers, electronic Hour Meters / Timers, electronic LED Timers Codix 523 For use as a timer, hour meter or short-time meter Pulse width measurement (operating time) Time interval measurement (start/stop) DC 000000 0... 30V

More information

Set Point Controller OC557. Operator s Manual

Set Point Controller OC557. Operator s Manual OC557_Manual_GB1206D Set Point Controller OC557 4 20mA Input Operator s Manual METRIX ELECTRONICS LTD. Tel: +44 (0)845 034 3234 Minchens Court, Minchens Lane Fax: +44 (0)845 034 3233 Bramley, Tadley, Hampshire

More information

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Z-D-IN. RS485 Modbus Module 5 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings -

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

SPACESCAN SERIES SS 02

SPACESCAN SERIES SS 02 Description 0-10 metre sensing range 12 to 384 channels Available with channel spacing of 5, 10 or 20 mm Active length of 225 mm to 1920 mm Housing length of 300 mm to 1980 mm Plug connection 18-30 V dc

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Electronic Pulse Counter Combination device

Electronic Pulse Counter Combination device Electronic Pulse Counter Combination device measuring monitoring analysing Input: pulse counter, time meter Display: 6-digit LED Height of digits: 14/8 mm Operation with front-panel buttons Material: plastic

More information

Micro-DCI 53ML5100 Manual Loader

Micro-DCI 53ML5100 Manual Loader Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with

More information

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency 1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching

More information

PROPORTIONAL VALVES Sentronic plus

PROPORTIONAL VALVES Sentronic plus 04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital

More information

SAUTER flexotron RDT405 Manual

SAUTER flexotron RDT405 Manual SAUTER flexotron 400 - RDT405 Manual P100012100 Table of contents DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Fr. Sauter AG however, makes no warranties

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information