1 products line * supplies Supplies KD line The feeding supplies of KD line had been developed to industrial installation, whose operation is continuous and requires component trustworthy. Constructed with the most modern techniques of keyed supplies, it possesses high income, reduced dimensions, possibility of linking of supplies in parallel and housing for DIN rail. KFT line New KFT supplies possess a new and modern housing, developed for more practical and application in the work stations. Available in the following versions: Output 24 Vdc / 5 A Output 24 Vdc / 10 A Output 24 Vdc / 20 A AS-Interface network 30 Vdc / 4 A
2 / 0.8A KF-KD-2401R/FR90-264Vac High performace against noises Redundant for parallel connection / 0.8A voltage Comsume current 90 to 264Vac or 130 to 370 Vdc 0.3A@90Vac; 0.1A@264Vac 26 VA (max.) 47 to 63 Hz Internal fuse 2A > A / 264 Vac Connection < A 0.9 A (use 50 C) polycarbonate bornes plug-in Connections diagram: 75g Vac F 1 F 2 Supply 1 Supply 2 Vdc Load F Input Alternate Current Vac N FEEDING SUPPLY LED 16(+) 17(-) 18(-) 22(+) 23(-) 24(-) Output Direct Current 24 Vdc 1(-) 2(+) Power Rail
3 / 1A KD-2401/FR90-264Vac Low cost Stabilized output in / 1A Protection aganist short and overload Technical Characteristics: supply Supply efficient / 1A 90 to 264Vac or 130 to 370 Vdc 0.3A@90Vac; 0.1A@264Vac 26 VA (max.) 47 to 63 Hz green led light on: blinking: overload light off: short-circuit Internal fuse 2A > 75 1A / 264 Vac Connection < A 1.2 A (use 50 C) polycarbonate bornes plug-in Connections diagram: 75g FEEDING SUPPLY Redundant System is not avaible in this version. Input Alternate Current Vac F N (+) 23(-) 24(-) Output Direct Current 24 Vdc LED 1(-) 2(+) Power Rail
4 / 5A KFT-2405R/AT Vac 128 Redundant to connection in parallel Fault indication via voltage / 5A 110/ 220Vac(automatic selection) 1.3A@88Vac; 0.7A@264Vac 150 VA (max.) 47 to 63 Hz Internal fuse 4A > 90 5A / 264 Vac < 60 5 A 5.5 A (use 50 C) aluminium and galvanized steel Connection screwed terminals 2.5mm 2 650g Vac F 1 Supply 1 Vdc Load F 2 Supply 2
5 KFT-3004R-AT110/220Vac 30Vdc / 4A KFT-3004R/AT Vac Indicate to AS-Interface network Fault indication via The KFT-3004R supply must be used together with the expander module of ASI-KD-EF supply that has the inductors necessary to make the network modulation. ASI-KD-EF voltage 30.5Vdc / 4A 110/ 220Vac(automatic selection) 1.3A@88Vac; 0.7A@264Vac 150 VA (max.) 47 to 63 Hz Internal fuse 4A > 90 4A / 264 Vac 30.5Vdc < 60 4 A 4.5 A (use 50 C) aluminium and galvanized steel Connection screwed terminals 2.5mm 2 650g application ASI Control Panel KFT-3004R PLC ASI-KD-EF Field
6 / 10A KFT-2410R/AT Vac Redundant to connection in parallel Fine adjust of the output voltage The KFT-2410R supply was specially developed to applications in industrials networks as DeviceNet and Profibus DP. 128 voltage / 10A 110/ 220Vac(automatic selection) 2.6A@88Vac; 1.4A@264Vac 300 VA (max.) 50 to 60 Hz Internal fuse 4A > 92 10A / 264 Vac (adjustable from 22 to 28Vdc) < A 11 A (use 50 C) aluminium and galvanized steel Connection screwed terminals 2.5mm g Vac F 1 Supply 1 Vdc Load INPUT F FEEDING SUPPLY + OUTPUT ALTERNATE CURRENT DIRECT CURRENT F 2 Supply or 220Vac N - LED
7 / 20A KFT-2420R/220Vac 128 Redundant to connection in parallel Fine adjust of the output voltage voltage / 20A 220Vac 3A@242Vac 600 VA (max.) 50 to 60 Hz Internal fuse 4A > 90 20A / 242 Vca (adjustable from 22 to 28Vdc) < A 22 A (use 50 C) aluminium and galvanized steel Connection screwed terminals 2.5mm g Vac F 1 Supply 1 Vdc Load INPUT F FEEDING SUPPLY + OUTPUT ALTERNATE CURRENT DIRECT CURRENT F 2 Supply 2 220Vac N - LED
8 Addresses: HEADOFFICE - SÃO PAULO Rua Tuiuti, Tatuapé São Paulo - SP - Cep: Phone: Fax: vendas@sense.com.br FACTORY - MINAS GERAIS Av. Joaquim Moreira Carneiro Santana Santa Rita do Sapucaí - MG - Cep: Phone: Fax: BRANCH OFFICE - Campinas Av. Barão de Itapura, º andar - sala: 22 Botafogo - Campinas-SP - Cep: Phone / Fax: campinas@sense.com.br BRANCH OFFICE - Porto Alegre Rua Itapeva, 80 - conj Passo da Areia Porto Alegre-RS - Cep: Phone: Fax: palegre@sense.com.br BRANCH OFFICE - Rio de Janeiro Rua Almirante Tamandaré, 66 sala: Flamengo Rio de Janeiro - RJ - Cep: Phone: National Sellers ABS - Sistemas de Automação Ltda. Poços de Caldas - MG Phone: Fax: absautomacaomg@matrix.com.br AVATEC Representações Ltda. Vitória - ES Phone: Fax: avatec.representacao@uol.com.br COMTÉCNICA Automação Industrial Ltda. Fortaleza - CE Phone / Fax: comtecnica@comtecnica.com.br ELCONI Com. Rep. de Elétrico e Teleinform. Ltda. Curitiba - PR Phone: Fax: vendas@elconi.com.br ELETRO NACIONAL Comércio Representações Ltda. Joinville - SC Phone / Fax : vendas@eletronacional.com.br KIKUCHI Representação Ltda. Piatã - BA Phone: Fax: kikuchivendas@uol.com.br LOBRIM Comércio e Representação Ltda. Recife - PE Phone / Fax: lobrim@rimafel.com.br NAM Comércio Representações Técnicas Ltda. São Luiz - MA Phone: Fax: nam.miotto@elo.com.br PACNET Com. Eletro Eletrônicos Ltda. Goiânia - GO Phone: Fax: vendas@pacnetprodutos.com.br Rev.B - 02/ We rerserve the rights of modify the information showed here without prior warning.
AF-300 E11 Adjustable Frequency Drive
AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed
More informationKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationHenkel Installation Handbook LINEGUARD 2001
Henkel Installation Handbook LINEGUARD 2001 HENKEL ITALIA S.r.l. Microprocessor instruments Henkel Installation Handbook Lineguard 2001 Page 2 Summary 1. The Microprocessor Instruments... 4 1.1. Norms
More informationSITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.
SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.
More informationMG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV
MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper
More informationG.R.A.S. Sound & Vibration
Instruction Manual Single-channel Low-noise Measuring System consisting of: ½-inch Low-noise Level Microphone System Type 40HH and Power Module Type 12HF 40HH 12HF G.R.A.S. Sound & Vibration Skovlytoften
More informationFibre Optic Modem ODW-611
Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationInstallation and User Guide 458/CTR8 8-Channel Ballast Controller Module
Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach
More informationEZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001
EZCOM-1 PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS Rev 1.3 - March, 2001 CONTENTS Page INTRODUCTION 1 SPECIFICATIONS 1 LIST OF SUPPLIED ITEMS 1 INSTALLATION & TESTING
More informationMicro-DCI 53ML5100 Manual Loader
Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with
More informationJunior Max (JR Max ) Controller
Get more done TM Junior Max (JR Max ) Controller stations Operating Instructions Thank you for purchasing this advanced, highly featured Irritrol Junior MAX controller. The Junior MAX is the latest addition
More informationDescription Diagram Page
notiziario tecnico 2004 SISTEMA VIDEO 4+n installation wiring diagrams VIDEO SYSTEM 4+n INDEX: Description Diagram Page Section of wires 2/UK Suggestions for the correct installation 3/UK Terminal functions
More informationUNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load
More informationCEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)
7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN) produced according to ISO 9001: 2000 Ver. 0.2/11.04.2006 Art.-Nr.: 104 057 E 1 / 8 7-Segment Double
More informationPHASE ImmediaTV: Codificadores
PHASE ImmediaTV: Codificadores ITV-EN460d MPEG-4 AVC Modular Encoder...p. 2 MVN-EN460 MPEG-4 AVC opengear Encoder...p. 4 ITV-IP360d IP Streaming Modular Encoder...p. 6 MVN-IP360 Streaming opengear Encoder...p.
More informationBL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog
More informationSOFTLINK 300. Modules Specifications. Reference Manual
SOFTLINK 300 Reference Manual Edition 04/2011 Preface Purpose of the manual This manual gives you a brief overview of SOFTLINK 300 Modules. You can look up information on the description, order No., technical
More informationRSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable
RSSL1:1-KuXER Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System Outdoor Unit (ODU) Waveguide Switch & Status LNB 1 Coax cable Interface Terminal LNB 2 Indoor Unit Outdoor Unit Indoor
More informationDirect PWM. 1000/2000 Series POWERBLOK MODULE
Direct PWM 1000/2000 Series POWERBLOK MODULE Features A universal servo-drive integrated on a Power Hybrid Module. Designed for direct PWM Servo Control Designed for use with Deta Tau's PMAC controllers
More informationISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G
ISOMAG THE FRIENDLY MAG METER Converter EX CONVERTER Hazardous area Categories according to 94/9/CE Directive Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G Gas, mists or vapours Zone
More informationThe Art of Engineering
The Art of Engineering Functionality DPST Switch DPST Sensing Switch Transfer Switch Passive Splitter Ethernet Switch ASI 3G Switch or DA E/T Switch Optical Switch up to 006 MHz L-Band Broadband Ethernet
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More informationLONWORKS Fibre Optic Router
LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS
More informationLONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
More informationMB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN
Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically
More informationPassive UTP Transceiver Hub with Integral Camera Power Installation Guide
Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat4D - Four (4) Channel Passive UTP Transceiver Hub with Integral HubSat42D - Four (4) Channel Passive UTP Transceiver includes
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationEAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS
EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION The Eltra multiturn Pro bus encoder series (Identi cation Number 0x0599) is complying to the Pro bus DP standard as described on the European Standard
More informationGMB101R BLACK BURST & PATTERN GENERATOR GMB101R-M 09/06/08
4 fixed Black Burst outputs Test output in CV and Y/C Selection of 8 test patterns Output with correlated phase PAL / NTSC 1KHz balanced audio output GMB101R-M 09/06/08 1 1.0 OVERVIEW The GMB101R Black
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationFibre Optic Modem ODW-622
Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.
More informationFibre optic router for TP/FT-10 LRW-112PP
Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT
More informationA COMPUTER VISION SYSTEM TO READ METER DISPLAYS
A COMPUTER VISION SYSTEM TO READ METER DISPLAYS Danilo Alves de Lima 1, Guilherme Augusto Silva Pereira 2, Flávio Henrique de Vasconcelos 3 Department of Electric Engineering, School of Engineering, Av.
More informationSet for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8
Type code Ident no. 1545077 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between
More informationABB i-bus EIB Universal dimmer 6155 EB for Installation
73-1 - 5975 23459 ABB i-bus EIB Universal dimmer 6155 EB - 101-500 for Installation Operating instructions only for authorized, skilled electricians with EIB training Important instructions Attention It
More informationGamma instabus. Technical product information
Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output
More informationMASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase
MASTER DIALOG ERM 8-20kVA three/single phase ERT 10-160kVA three/three phase The Master Dialog range uses advanced double-conversion on-line (VFI) technology with a transformer isolated inverter output
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationFREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS
MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422 remote control
More informationModel /29S RF Splitter
Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationEA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS
EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION The Eltra singleturn Pro bus encoder series (Identi cation Number 0x0599) is complying to the Pro bus DP standard as described on the European Standard
More informationEAM PROFIBUS MULTITURN ABSOLUTE ENCODER. Multiturn ABSOLUTE ENCODERS. Presentation. Hardware installation device
Presentation EAM PROFIBUS MULTITURN ABSOLUTE ENCODER The Eltra multiturn Profi bus encoder series (Identifi cation Number 0x0599) is complying to the Profi bus DP standard as described on the European
More informationtechnical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current
Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according
More informationX4 Process Controller
available KW 22-2004 Description New Slot 12NC PR5510/04 Serial I/O RS232 und RS485/422 1/2 9405 355 10041 PR5510/06 PR5510/07 PR5510/08 PR5510/09 PR5510/12 PR5510/14 PR1721/31 PR1721/32 PR1721/34 PR1721/35
More informationFN Series Scalable N+1 UPS 3kVA to 40kVA Tower
FN Series Scalable N+ UPS kva to 0kVA Tower Advanced Features: * Parallel Units with a Single of up to 0kVA * True N+ Redundancy * ECO Mode: 97% Efficiency * DSP Double-Conversion On-line Sinewave Design
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationCapacitance Level Measurement Electronic insert FEC 12
Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation
More informationACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE
MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you
More informationPRELIMINARY Sunny Boy 240-US
PRELIMINARY Sunny Boy 240-US SB 240-US-10 Optimized reliability Simple installation Unrivaled monitoring SMA-backed security Multigate technology allows for reduced component count Private band powerline
More informationInstruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control
Series 3000 Model R-165A Audio/Video IF/RF Relay Panel Instruction Manual CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. Lyndonville NY 14098 www.monroe-electronics.com Table
More informationPassive UTP Transceiver Hub with Integral Camera Power Installation Guide
Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat8D - Eight (8) Channels HubSat82D - HubSat8D w/eight (8) HubWayAv Balun/s for s HubSat83D - HubSat8D w/eight (8) HubWayDv
More informationSynchro System PHOTO NOT AVAILABLE. Description. Applications. Features
Innovative Solutions in Engineering BBG-RSSS-90-400-1 Redundant Serial to Synchro System Description PHOTO NOT AVAILABLE Applications Radar Systems (antenna azimuth) Navigation Systems (gyrocompass, speedlog,
More informationODW-621. RS-232 Point-to-point applications
Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More informationEA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator
EA63-7D Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 -
More information263 Series LED Bargraph Indicator and Controllers
263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationSUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL
STP 8000TL-10 / STP 10000T-10 / STP 12000TL-10 / STP 15000TL-10 / STP 17000TL-10 SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL Economical Reliable Flexible Simple Maximum efficiency of
More informationHC500 Heater Controller
HC500 Heater Controller Diagnostic HETRONIK GmbH Heisinger Str. 12 D-87437 Kempten / Germany phone: +49 / (0)831-56 58 59-34 fax: +49 / (0)831-56 58 59-39 e-mail: contact@hetronik.de www.heatcontrol.com
More information2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES
EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationOperating Instructions
COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic Preselection Counter Two preselections NE 216 Contents Page 1 Safety indications... 2 2 Get to know your NE 216... 4 2.1 NE216 components...
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationPIX/2 Operation Manual
Contents Description... Page 3 PIX/2 variations... Page 3 Choosing the Correct Cameras... Page 4 PIX/2 Operation Manual Video Split Screen and Fade Controller Models PX101EX PX101M1 PX101XC PX201EX Unpacking...
More informationSOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION. Soft Starter Catalog 2018 Release n.
380 to 600V Nominal current 6 to 200A ST with Soft Start STO with Soft Start + Overload Relay Internal by pass relay SOFT STARTER CD AUTOMATION POWERED BY INNOVATION We are delivering Real Cost Benefits
More informationMAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams
MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic
More informationKramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier
Kramer Electronics, Ltd. USER MANUAL VM-20HD Dual 1:10 HD/SD SDI Distribution Amplifier Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Your VM-20HD Dual 1:10 HD/SD
More informationAnalogue output module DAO 081
ANALOGUE OUTPUT MODULE DAO 081 Analogue output module DAO 081 for eight ±10 V DC outputs This analogue output module is used for driving components capable of being analogue driven (e.g. proportional pressure
More informationSIMATIC. ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Preface. Properties 1. Parameters 2. Error and system messages 3
Preface SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Properties 1 Parameters 2 Error and system messages 3 Response times 4 Manual
More informationModular Power System acc. VG MoFess Module for Military Ground Vehicles
This new modular Power System for Military Ground Vehicles based on a standard box incorporating up to three different power modules. The power inlet module (230 V AC) includes line filter, lightning protection
More informationEMC Solutions Noise filtering
Power & Signal Quality TRABTECH EMC Solutions Noise filtering Interference-free power supply and signal transmission A permanent supply and safe data link are essential for the operational reliability
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationDATA SHEET ML210 ML210_IT_EN_DS017REV12_IS
DATA SHEET ML210 INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 TECHNICAL DATA 2 ACCURACY 3 OVERALL DIMENSION 4 VISUALIZATION PAGES 5 ELECTRICAL CONNECTIONS 6 TABELLA DELLE PRECISIONI 10 ML210/MS2500: MI-001
More informationCET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES
CET DOUBLE COUNTER WITH TWO THRESHOLDS Type: LBM62CD 6 DIGITS DOUBLE DIGITAL COUNTER WITH TWO SEPARATE COUNT IMPUTS LBM62CD counter is a double counter with two separate counters. Each counter s input
More informationFACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE
FACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE Table of Contents AS-Interface Basics... 3 Addressing Modules... 4 Handheld Programmer (Reading Inputs and Settings Outputs)... 5 Gateway
More informationCONDITIONER TERMINAL BLOCK 8 ISOLATED ANALOG INPUTS STB 582
CONDITIONER TERMINAL BLOCK 8 ISOLATED ANALOG INPUTS STB 582 Eight 3-port isolated analog inputs INPUTS / OUTPUTS / POWER SUPPLY Protected inputs Levels from ± 50mV FS to ± 40V FS Low-pass 2 nd order filter
More informationMONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE
More informationSentronic PLUS. Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage
More informationLOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN
LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN STANDARD FEATURES ±1,999-count display span ±200 mv to ±200 Vdc ranges True-differential input with 80 db CMR 3-wire ratio
More informationOperating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics
Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical
More informationSINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical
More informationRecording to Tape (Analogue or Digital)...10
c o n t e n t s DUAL MIC-PRE Green Dual Mic Pre (introduction).............................4 Section (i): Setting Up Power Connections...........................................4 Power Supply................................................5
More informationDC-to-DC Technology. 135 mm LOW-NOISE FAN FEATURES
DC DC-to-DC Technology 135 mm LOW-NOISE FAN FEATURES ATX 2.4 Supports Haswell, Skylake and Kaby Lake plus the latest Intel and AMD processor systems. Higher Energy Efficiency This power supply is 80 PLUS
More informationFREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS
FREQUENCY CONVERTER MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422
More informationADJUSTABLE SPEED DRIVES. nc1 Drive
ADJUSTABLE SPEED DRIVES nc1 Drive Ultra-Compact Sub-Micro Drive The nc1 is a sub-micro, or nano-sized drive with a full range of features to meet the needs of nearly any user. The nc1 is designed to be
More informationLED Driver Linear / area fixed output
Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For
More information24V, 15A, CAPACITOR-BASED BUFFER MODULES CAPACITOR-BASED BUFFER MODULES SHORT-FORM DATA MARKINGS
CAPACITOR-BASED BUFFER MODULES Built-in Capacitors as Energy Source (EDLC Electrochemical Double Layer Capacitors) Wide Temperature Range from -40 C to +60 C Typically >10 Years Operational Lifetime Expectancy
More informationTruck router (3Gbps/HD/SD/ASI)
NVISION 8288 Truck router (3Gbps/HD/SD/ASI) The ultra-compact NVISION 8288 truck video routers are the world s smallest large routers with full broadcast quality, resilience and advanced control systems.
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More informationUDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4
UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines
More informationUSER GUIDE FRMT EN S.45.16
USER GUIDE FRMT EN CONGRATULATIONS ON YOUR CHOICE We are pleased to offer you the finest technology in grain quality control. Your moisture tester was submitted through an extensive quality control process
More informationZ-D-IN. RS485 Modbus Module 5 Digital Inputs
S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings -
More informationSureFire PDI Lubricator
SureFire PDI Lubricator Automatic, Oil & Fluid Grease General The SureFire PDI Lubricator is an automatic, robust and durable pump that can handle oil and soft greases. Its compact size is designed to
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationSCALE & WEIGHT DISPLAYS
The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters
More informationLED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data
Product description 1-channel for indoor use Inbuilt for luminaires of protection class I Output current and output voltage adjustable FA output 12 V TC input channel ominal life of 50,000 h (at ta max.
More informationIMPAC Infrared Thermometers
IMPAC Infrared Thermometers focusable optics for non-contact temperature measurements on metals, ceramics, graphite etc. between 300 and 3300 C IS 140 IGA 140 IS 140-PB IGA 140-PB Short response times
More information