Revised Textbook Edition Digital Radiography & PACS

Size: px
Start display at page:

Download "Revised Textbook Edition Digital Radiography & PACS"

Transcription

1 Fleitz Continuing Education Jeana Fleitz, M.E.D., RT(R)(M) The X-Ray Lady 6511 Glenridge Park Place, Suite 6 Louisville, KY Telephone (502) Fax (502) Web address address x-raylady@insightbb.com Revised Textbook Edition Digital Radiography & PACS Approved for 9 Category A CE Credits by American Society of Radiologic Technologists (ASRT) Course Approval Start Date 01/01/08 Course Approval End Date 02/01/13 Florida Radiologic Technology Program 9 Category A CE Credits (Technical) Provider Approval # Course Approval Start Date 12/01/07 Course Approval End Date 01/31/14 Iowa Department of Public Health Bureau of Radiological Health 9 Category A CE Credits for General x-ray & Limited Chest, Chest/Extremities Course Approval Start Date 12/24/07 Course Approval End Date 05/01/13 Kentucky Radiation Operator Certification Program Course Approval Start Date 2007 Course Approval End Date 02/01/13 Please call our office after the course approval end date for course renewal status Please let us know if your mailing address or address changes. Thank you. A Continuing Education Course for Radiation Operators

2 Digital Radiography and PACS Course Description This homestudy course titled Digital Radiography and PACS introduces the technologist to digital imaging and how it functions and the differences between digital radiography and conventional film/screen radiography. The course provides a basic overview of the concepts of latent image formation for both conventional and digital imaging processing, with an introduction to PACs and how digital image processing integrates with digital storage systems. Objectives: Upon completion of this course, the participant will: 1. Select the best action to take when image-processing errors occur that affect image clarity. 2. Given basic errors associated with optimal receptor exposure, selection of exposure factors, and controlling and monitoring patient radiation exposure select the correct response. 3. Differentiate between myths and facts associated with digital imaging systems. 4. Given common situations related to exposure recognition failure or histogram analysis error, select the correct response. 5. Select the best corrective action to take when errors occur in image contrast, recorded detail and image artifacts. 6. List the basic quality control tasks that the radiographer must perform when using digital radiography systems. 7. Define teleradiography and recall basic facts about the system operation. 8. Recall the radiographer s responsibility in maintaining patient confidentiality when using digital radiography and PACs systems. 9. Recognize basic guidelines for selection of digital imaging and PACS systems. 10. Recall important facts concerning radiation dose and digital imaging systems. 11. Identify correct statements regarding quality control and quality assurance of digital imaging and PACS systems.

3 Fleitz Continuing Education Jeana Fleitz, M.Ed., RT(R)(M) "The X-Ray Lady" 6511 Glenridge Park Place, Suite 6 Louisville, KY Telephone (502) Fax address xraylady@insightbb.com Web Address Homestudy Course Directions Directions To complete this course read the reference included with your homestudy course. We suggest that you read the reference prior to answering the post-test questions. Complete the post-test questions. If you have difficulty in answering any question, refer to the reference. Complete the Answer Sheet and Course Evaluation Complete the post-test and record your responses on the answer sheet and complete the course evaluation. You may mail your answer sheet to 6511 Glenridge Park Place, Suite 6, Louisville, KY If you mail your answer sheet and course evaluation, retain a copy before mailing. We request that you do not fax your answer sheet unless you are within two weeks of your expiration date. If you fax your answer sheet and course evaluation, obtain verification from the machine that the fax was delivered or call our office for verification. OR Use the Online Answer Sheet on our website homepage at After completing the ONLINE Answer sheet, just hit submit to send via . Remember to also complete the online course evaluation. Grading and Issuance of a Certificate Your answer sheet will be scored within 1-2 days of arrival in our office. To obtain continuing education credit, you must have a cumulative average score of at least 75%. Verification of awarded continuing education for this course will be submitted to the following states: KY, IA, FL. For ARRT and all other states, please self-report to the state radiation certification agency in your state and the ARRT and any other organizations. You will be awarded a certificate verifying satisfactory completion of this course, or notification if you do not. We are now ing certificates so be sure to include your address. Please let us know if you prefer to receive a copy in the mail and allow 4-5 days to receive your copy. Need Additional Information You may call our office (502) voice mail. Our office hours are 9 a.m. 6 p.m. Monday through Friday. The office operates on Eastern Standard Time and is closed on major holidays. You may also us at xraylady@insightbb.com. For information, about courses or to order online, visit our web site at The X-ray Lady Refund and Exchange Policy, Certificate Replacement Policy, and other related policies are included in each course.

4 Jeana Fleitz The X-Ray Lady 6511 Glenridge Park Place, Suite 6 Louisville, KY Telephone (502) Website us at xraylady@insightbb.com Important Information Refund Policy (8/2011) Applies to Hardcopy Courses Customers have 30 days from the date of the original purchase to receive a refund. After 30 days customers may receive a credit towards future purchases for any materials/book returned to us. All refunds and credits will be subject to a $5 re-stocking fee per course. There will be no refunds or credits for shipping & handling charges once a course has already shipped to you. Refunds will not be issued until the course material/book is received in our office and considered to be in excellent condition. Customers are responsible for the shipping costs when returning materials to our company for a refund. Credits expire after one year from the issuance date. Refund Policy (8/2011) Applies to Ebook Courses No refunds will be issued for Ebook courses once the materials have already been sent. Customers wishing to return an Ebook course will have 30 days from the original date of purchase to receive a credit towards a future purchase minus a $5 processing fee. Credits expire after one year from the issuance date. Exchange Policy (1/2009) An exchange of a course may be made up to 30 days after the date of purchase. Customers are responsible for the shipping costs when returning materials for an exchange. After materials have arrived at our office and are inspected and are in excellent condition the replacement materials will be shipped. Customers are responsible for payment of new shipping costs and any difference in price for the replacement course The following applies to both the Refund and Exchange Policies Refunds will be issued in the same manner as the original order (i.e., credit card/check). Refunds on materials purchased with a personal or company check will be refunded with a cashier s check after initial check payment has cleared the banking process. No refund/exchange will be made for courses that are within one month of the course approval expiration date. About Your Certificates and Faxing Your Answer Sheets Effective : All course certificates will be sent via unless we are otherwise notified. Be sure to add our to your address book so that your certificate is not sent to your junk/bulk mail. If you have a new or different please notify our office or make note of it on your answer sheet. Please DO NOT FAX your course answer sheet(s) and evaluation form(s) to us unless your certificate is going to expire within two weeks of the date you complete the course. Instead we request that you maintain a copy of your answer sheet for each course you complete, and mail these to us at the address listed above OR use our online generic answer sheet on our website at (the link is in the top right hand corner on the homepage). Certificate Replacement Charge A $5 replacement fee per certificate will be charged for any request that occurs 30 days after the issuance date on the original certificate. We can send a duplicate certificate via your address or U.S. mail service. If you request that your replacement certificate be faxed, there will be a $3 fee per page. Please retain your course certificates in case the ARRT or state licensing agency conducts an audit of your records. Because of the staff time required to research and prepare a replacement certificate, we assess a charge for this service. This will not affect the majority of customers.

5 Jeana Fleitz, M.Ed., RT(R)(M) The X-Ray Lady 6511 Glenridge Park Place, Suite 6 Louisville, KY Telephone (502) Fax (502) Address xraylady@insightbb.com Web Address Disclaimer Notice This course has been evaluated and approved for a specified amount of continuing education by the agencies listed on the cover. The provider of this course does not imply or guarantee that completion of this course automatically ensures renewal or initial issuance of any state, national, or federal x-ray certification or licensure requirements. It is the responsibility of the individual, completing this course, to understand and to comply with state, national, and federal x-ray certification and licensure regulations regarding initial and renewal requirements. Further, the provider of this course claims no responsibility for determining if the topic or amount of continuing education credit is appropriate for any person. The field of radiography and medicine is ever changing. Readers are advised to check the most current product information provided by equipment and supply manufacturers. The provider of this course does not assume any liability for any injury and/or damage to persons or property arising from information contained in this course. The information contained in this course should not be used for medical diagnosis or treatment. Users of this information are encouraged to contact their physician or health care provider for any health related concerns. The X-Ray Lady, LLC is neither responsible nor liable for any claim, loss, or damage resulting from the use of this course. Earning CE Credit This activity may be available in multiple formats or from different sponsors. Continuing education credit can be awarded only once for the same activity.

6 Digital Radiography and PACS Posttest (Revised Textbook Version) 1. In medicine, digital imaging was first used with the introduction of: a. ultrasonography b. magnetic resonance imaging (MRI) c. computed tomography (CT) d. nuclear medicine scanning 2. Early picture archiving and communications systems (PACs) were developed by the: a. aviation industry b. U.S. military c. Department of Homeland Defense d. federal prison system 3. Improved image quality in computed radiography (CR) and digital radiography (DR) opened the way for to convert to a digital format. a. CT b. MRI c. ultrasonography d. mammography 4. Computed radiography was first introduced commercially in the U.S. in 1983 by Medical Systems. a. Fugi b. Phillips c. General Electric d. Hitachi 5. Conventional x-ray and CR requires all of the following, except: a. traditional x-ray room b. x-ray table c. wall Bucky d. detector 6. In DR the image will appear in to seconds. a. 1 2 b. 3 5 c d

7 7. Today most CR storage phosphor plates are made of: a. fluoride lithium b. barium fluorohalide c. calcium tungstate d. sodium fluoride 8. In DR there are no cassettes. a. True b. False 9. In conventional radiography, radiographic contrast is primarily controlled by: a. time of exposure (s) b. milliamperage (ma) c. kilovoltage peak (kvp) d. milliamperage-seconds (mas) 10. For CR and DR, mas has more influence on: a. shape distortion b. quantum mottle c. image noise d. reticulation of the image 11. The first full scale PACs in the U.S. was installed at the Veterans Medical Center in Baltimore in: a b c d Common computer output devices are: a. monitors b. printers c. speakers d. all of the above

8 13. A byte is made up of bits. a. 10 b. 8 c. 6 d The motherboard is the largest circuitry board inside the computer. a. True b. False 15. For the letter x, the binary code is: a b c d The central processing unit (CPU) is the personal computers (PC) box. a. True b. False 17. The connections for the information to flow within the computer is provided for by the: a. universal serial bus (USB)basic b. input/output system (BIOS) c. central processing system (CPU) d. random access memory (RAM) 18. The random access memory (RAM) is only temporary; once the computer has been turned off, the RAM is wiped clean. a. True b. False 19. Ports, on a computer, link: a. adapter cards and drives b. printers and scanners c. keyboards, mice, and other peripherals d. all of the above

9 20. By using universal serial bus (USB) ports on a computer, the user can connect up to devices to one single USB port. a. 30 b. 55 c. 127 d The main repository for programs and documents on a personal computer (PC) is the: a. hard drive b. sound card c. network card d. port 22. A digital versatile disk (DVD) holds up to times more than the compact disk (CD) drive. a. three b. seven c. nine d. thirteen 23. A wireless type of mouse device is considered a mouse. a. PS/2 b. serial c. infrared d. Bus 24. With the advent of wireless connections, keyboard makers use either infrared or radiofrequency (RF) signals. a. True b. False 25. A basic picture element on a display is known as a: a. matrix b. dot c. crystal d. pixel

10 26. All of the following are true regarding dot pitch, except: a. it is an arrangement of pixels b. is a measurement of how close the dots are located to one another within a pixel c. may be expressed as aperture grille or slot pitch d. the smaller the dot pitch of a display, the finer the resolution 27. Most modern PACs use a platform on their servers. a. windows-based b. UNIX c. LINUX d. Local area network (LAN) 28. Devices other than computers that can also be found on a network are: a. printers b. scanners c. barcode readers d. all of the above 29. A small area networked with a series of cables or wireless access points that allow computers to share information and devices on the same networks is a: a. modem b. LAN c. BUS d. Wide are networks (WAN) 30. The maximum number of peers that should be connected in a peer-to-peer network is: a. 2 b. 4 c. 6 d There can be multiple servers on a server-based network but there must be a dedicated server that controls the network. a. True b. False

11 32. The most commonly used wire as the connection medium in LANs is: a. twisted-pair wire b. coaxial cable c. fiberoptic cable d. infrared transmitter-wire 33. The biggest advantage of wireless connections is: a. privacy and confidentiality b. low cost c. mobility and convenience d. resolution of the connection 34. A network is the simplest device that can be used to connect several pieces of equipment together for network connection purposes. a. interface card b. hub c. switch d. bridge 35. A device used to read portions of messages and direct them to their intended target is referred to as a network. a. modem b. switch c. bridge d. router 36. When larger networks can be segmented, a network is created. a. modem b. switch c. bridge d. router 37. When devices communicate through a network interface card (NIC) each computer on the network will have the same address. a. True b. False

12 38. There are common topology configuration layouts possible on the devices connected on a network. a. two b. four c. six d. eight 39. Topology in which a network has multiple pathways interconnecting devices and networks is a: a. ring b. BUS c. Mesh d. Star 40. The first version of digital imaging and communications in medicine (DICOM) was completed in: a b c d The DICOM standard is made up of different parts ranging from image display to media storage. a. 24 b. 16 c. 8 d Unique identifier numbers are created based on all of the following, except: a. vendor number b. equipment serial number c. date, time, patient or processing number d. patient s ability to pay for the study 43. As images are compressed at higher values, some loss of image detail can occur. a. True b. False

13 44. Data travels along the network using an agreed on set of rules known as a net-work protocol. a. True b. False 45. All of the following are true regarding the CR cassette, except: a. looks like a conventional radiography cassette b. is backed by a thin sheet of aluminum c. contains calcium tungstate screens d. contains an antistatic material 46. In CR cassettes located between the active layer and the support that absorbs the stimulating light but reflects emitted light is the layer. a. color b. support c. backing d. conductive 47. With CR systems, the purpose of the reader is to: a. trap the electron signal b. release stored electrons c. convert the electrons to ions d. magnify the stored electrons 48. Although there will be variances among manufacturers, the typical throughput is cassettes per hour based on average hospital department workflow. a. 25 b. 50 c. 75 d In film/screen radiography resolution is determined by: a. the range of the kilovoltage used b. centimeter size and pathology c. type of image processing system used d. crystal size and thickness of the phosphor layer

14 50. Fuji Medical Systems reports that a 1-mR exposure at 80 kvp and a source-to-image distance of 72 inches will result in a luminescence value of 200, hence a speed class of: a. 100 b. 200 c. 300 d Imaging plates should be erased at least or when in doubt about the presence of exposure to the plate to remove background radiation and scatter. a. once a day b. every 48 hours c. once a week d. once a month 52. In CR, if a knee examination is to be performed and the examination selected is for the skull, this will result in: a. improper brightness b. improper contrast c. unacceptable action d. all of the above 53. In CR, it is not recommended that kvp values less than 45 or greater than be used because those values may be inconsistent and produces too little or too much excitation of the phosphors. a. 120 b. 95 c. 80 d Quantum noise results when: a. too much kvp is used b. the kvp range is low c. insufficient light is produced d. the exposure time is too long 55. Typically, high-resolution imaging plates are most often used for: a. extremities b. mammography c. examinations requiring increased detail d. all of the above

15 56. When using a stationary grid if the grid lines and the scanning laser are parallel, a wavy artifact known as a pattern occurs. a. moiré b. pi c. cross-hatch d. rhombic 57. All of the following are true regarding grid frequency, except: a. refers to the number of grid lines per centimeter or lines per inch b. the finer the grid line in the image the less they interfere with the image c. typical grid frequency is between 80 and 152 lines/inch d. the higher the frequency the greater the positioning latitude 58. For mobile radiography, a grid ratio of would be proper. a. 3 : 1 b. 6 : 1 c. 12 : 1 d. 18 : Parallel grids should not be used at distances less than inches. a. 48 b. 52 c. 65 d A sensitivity number (s) of 400 is the exposure of an S number of 200. a. four times b. three times c. twice d. half 61. The semiautomatic mode is especially useful for all of the following, except: a. odontoid process b. lumbosacral spot film c. sinuses d. hip with a prostheses

16 62. Cracks in the imaging plate appear as areas of on the image. a. radiolucency b. dark lines c. pinpoint dots d. static discharge streaks 63. A white grid-type pattern and white areas that correspond to the hinges results when the cassette is exposed with the back toward the source. a. True b. False 64. Detective quantity efficiency (DQE) refers to: a. conversion of CR to DR b. efficiency of resolution of the image c. how effectively scatter radiation is absorbed by the grid d. how efficiently a system converts the x-ray input signal into a useful output image 65. Automatic rescaling means that images are produced with: a. less magnification than is actually present b. uniform density and contrast regardless of the amount of exposure c. minimal scatter radiation d. the greatest degree of collimation 66. Smoothing is also known as: a. low-pass filtering b. high-pass filtering c. modulation transfer d. windowing 67. In CR veil glare may be effectively eliminated by: a. filtering b. image sampling c. aliasing d. shuttering

17 68. Image stitching technique eliminates the need for: a. large (36 inch) cassettes b. image annotation c. edge enhancement d. image sampling 69. An archive server in a PACs system is comparable to a room. a. waiting b. viewing c. processing d. file 70. Mammography requires a megapixel resolution to provide the viewing capacity needed. a. 5 b. 4 c. 3 d One of the most important features on a physician review station is the ability to: a. manipulate image density and contrast b. increase or decrease edge enhancement c. filter out extraneous white light d. view current and previous reports along with the images 72. How a set of images will be displayed on the monitor is referred to as protocol. a. scrolling b. hanging c. aliasing d. switching 73. The most common measurement function found on PACs stations is: a. distance b. resolution c. magnification d. degree of angulation

18 74. Archive technology continues to make drastic improvements each year; the storage capacity is said to double every to months. a. 1 2 b. 3 6 c d When data is broken up into pieces it is referred to as : a. enhancing b. digitizing c. striping d. mirroring 76. The most common redundant array of independent disks (RAID) level used for a PACs archive is a RAID : a. 0 b. 1 c. 3 d The first ultra density optical disk (UDO) was introduced in: a b c d Tape libraries being offered in 2006 held between 24 and disks. a. 800 b. 638 c. 424 d A type of storage that is connected directly via cable connections and shows up on the computer as different partitions for use is referred to as: a. DAS b. NAS c. PNP d. SAN

19 80. Disaster recovery involves: a. rebooting the CR or DR system b. making copies of each tape of disk and sending them to an off-site location c. manual operation directions in case of a system crash d. designation of key personnel in case of a crisis 81. All of the following are true regarding CCD film digitizers, except: a. uses fluorescent bulbs that shine through the film b. are more expensive than laser digitizers c. can take up to 80 seconds to scan one film d. can have problems with extreme light and dark areas on the film 82. Dry imagers use to process the latent image. a. heat b. chemicals c. infrared d. lasers 83. Film can and will be used in the filmless radiology department because: a. A backup ability to print is needed in case the PACS goes down b. When a PACS is installed, there are a few departments that are difficult to convert to PACS initially c. Films are required for legal cases when a copy needs to be viewed in court d. All of the above 84. One sheet of dry laser film costs approximately $. a b c d Quality control measures are taken to ensure that radiologic procedures are: a. performed safely b. appropriate for the patient c. performed efficiently and produce a high quality image d. all of the above

20 86. Continuous quality improvement (CQI) tends to focus on: a. people b. services c. processes d. organizations 87. The American College of Radiology (ACR) suggests that quality control tests be performed at least: a. semi-annually b. monthly c. weekly d. daily 88. The weakest link in the digital imaging chain often is the: a. printer b. workstation c. scanner d. monitor 89. For luminance, reflection, noise and glare test, the technologist should verify that all luminance patches are clearly visible. a. 32 b. 24 c. 16 d The TG-18-QC test pattern is used to test for: a. reflection b. geometric distortion c. luminance response d. luminance dependencies 91. All annual testing and acceptance testing should be performed by a qualified: a. medical physicist b. densitometry technologist c. quality control technologist d. board certified radiologist

21 92. After acceptance testing of the workstation processing speed, if no changes are seen on the weekly-established pattern, the procedure can then be done on a basis. a. annual b. semi-annual c. quarterly d. monthly 93. Compression is used to: a. reduce the technologist s workload b. minimize strain on the image processing system c. increase speed of the network transfer of images d. expand capability of the network 94. The first line of defense in preventing, recognizing and reporting QC issues is the: a. radiologist b. medical physicist c. referring physician d. radiologic technologist 95. Daily QC duties for technologists includes: possible responses a. 2 and 3 b. 3 and 4 c. 2, 3, & 4 d. 1, 2, 3, & 4 1. inspect and clean cassettes 2. inspect hinges and latches and laser printers 3. erase imaging plates 4. verify digital interfaces and network transmission 96. Reject analysis requires: a. repeat reason b. number of repeats c. the responsible technologist(s) d. all of the above

22 97. Image plates (IPs) should be removed from the cassette and inspected visually for: possible responses a. 1 and 2 b. 3 and 4 c. 1, 2, & 3 d. 1, 2, 3, & 4 1. dirt and hair 2. lint 3. scratches 4. cracks 98. Because IPs contains a small amount of, they must be discarded according the state and U.S. Environmental Protection Agency (EPA) regulations. a. lead b. arsenic c. barium d. copper 99. A system of preventative maintenance (PM) typically takes place on a basis. a. monthly b. quarterly c. semi-annual d. annual 100. When tested, the reproducibility of exposures produced should be plus or minus % within established exposure parameters measured in multiple exposures. a. 2 b. 5 c. 9 d. 11

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba Equipment Quality Control for Digital Radiography February 22, 2018 Imaging Physics CancerCare Manitoba Purpose An equipment quality control (QC) program establishes baseline performance levels, tracks

More information

The Versatile and Powerful ACLxy. ACLxy

The Versatile and Powerful ACLxy. ACLxy The Versatile and Powerful ACLxy ACLxy ROLLING into a Clinic, Imaging Center and Hospital Near You! COMPUTED RADIOGRAPHY (CR) IS RAPIDLY JUST THE BEGINNING. THE OREX CR SOLUTION BECOMING A DRIVING FORCE

More information

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline Medical Display Performance and Evaluation Mike Silosky, MS University of Colorado, School of Medicine Dept. of Radiology 1 Objectives Review display function, QA metrics, procedures, and guidance provided

More information

CARESTREAM DIRECTVIEW Elite CR System

CARESTREAM DIRECTVIEW Elite CR System CARESTREAM DIRECTVIEW Elite CR System Improve workflow, productivity, and patient throughput. The CARESTREAM DIRECTVIEW Elite CR System is small, easy to install and easy to use. This powerful distributed

More information

CARESTREAM DIRECTVIEW Elite CR System

CARESTREAM DIRECTVIEW Elite CR System CARESTREAM DIRECTVIEW Elite CR System Improve workflow, productivity, and patient throughput. The CARESTREAM DIRECTVIEW Elite CR System is small, easy to install and easy to use. This powerful distributed

More information

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

DirectView Elite CR System. Improve workflow, productivity, and patient throughput. Improve workflow, productivity, and patient throughput. DirectView DirectView Compact, single cassette CR systems designed to improve workflow, productivity, and patient throughput. The is small, easy

More information

FFDM Quality Control in Canada - a Vendor Neutral Approach

FFDM Quality Control in Canada - a Vendor Neutral Approach FFDM Quality Control in Canada - a Vendor Neutral Approach Rasika Rajapakshe, PhD, FCCPM BC Cancer Agency-Center for the Southern Interior Kelowna, BC, Canada 2011 Joint AAPM/COMP Meeting August 4, 2011

More information

World First Slim Cassette Type Digital Mammo. Upgrade Solution

World First Slim Cassette Type Digital Mammo. Upgrade Solution World First Slim Cassette Type Digital Mammo. Upgrade Solution Still Analog? Slim Cassette Type Digital Mammo. Upgrade Solution Contents 3 P. 5 P. 7 P. 9 P. 11 P. 13 P. 1824C & 2430C, easy digitalization

More information

Scope: All CT staff technologist

Scope: All CT staff technologist APPROVED BY: Radiology Technical Director Page 1 of 6 Purpose: The QC program assesses relative changes in system performance as determined by the technologist, service engineer, qualified medical physicist,

More information

Essentials of Digital Imaging

Essentials of Digital Imaging Essentials of Digital Imaging Module 3 Transcript 2016 ASRT. All rights reserved. Essentials of Digital Imaging Module 3 Display 1. ASRT Animation 2. Welcome Welcome to the Essentials of Digital Imaging

More information

Guidelines for Assuring Softcopy Image Quality

Guidelines for Assuring Softcopy Image Quality Guidelines for Assuring Softcopy Image Quality What s inside? Quality Control Guidelines Softcopy QA testing and frequencies Danny Deroo Product and R&D Manager QA Products ABSTRACT To ensure diagnostic

More information

Imaging solutions for any size patient and any size budget.

Imaging solutions for any size patient and any size budget. Imaging solutions for any size patient and any size budget. VetTek V e t e r i n a r y X - R a y S y s t e m s VetTek We See Things Differently & It Shows In Your Image Imagine a veterinary x-ray system

More information

Monitor QA Management i model

Monitor QA Management i model Monitor QA Management i model 1/10 Monitor QA Management i model Table of Contents 1. Preface ------------------------------------------------------------------------------------------------------- 3 2.

More information

The Digital Debate. Competing Technologies. Up and Coming 1/5

The Digital Debate. Competing Technologies. Up and Coming 1/5 The Digital Debate axisimagingnews.com/2001/04/the-digital-debate/ The long-awaited transition from film-based radiography to electronic review of medical images has begun. There are a number of factors

More information

Display Quality Assurance: Considerations When Establishing a Display QA Program. Mike Silosky, M.S. 8/3/2017

Display Quality Assurance: Considerations When Establishing a Display QA Program. Mike Silosky, M.S. 8/3/2017 Display Quality Assurance: Considerations When Establishing a Display QA Program Mike Silosky, M.S. 8/3/2017 Objectives and Outline Why, Who, What, When, Where? Discuss the resources that may be needed

More information

Overview. ACR Accreditation Update in Mammography. ACR Topics. Requirements Today. What s Coming For Tomorrow

Overview. ACR Accreditation Update in Mammography. ACR Topics. Requirements Today. What s Coming For Tomorrow ACR Accreditation Update in Mammography Eric Berns, PhD University of Colorado Hospital Denver Health Medical Center Denver, CO *No financial disclosures to report Overview ACR Topics Requirements Today

More information

Ride the Lightning. A Review of Radiographic Physics

Ride the Lightning. A Review of Radiographic Physics Ride the Lightning A Review of Radiographic Physics Overview Basic principles of x-ray production Imaging equipment Quality Control Technical Factors Image QA Preparing for the registry The ARRT just wants

More information

Performance Evaluation of Industrial Computed Radiography Image Display System

Performance Evaluation of Industrial Computed Radiography Image Display System Performance Evaluation of Industrial Computed Radiography Image Display System More info about this article: http://www.ndt.net/?id=21169 Lakshminarayana Yenumula *, Rajesh V Acharya, Umesh Kumar, and

More information

Request for Proposals

Request for Proposals Request for Proposals Reference: ERDFIAI2012-4006A Caring First Ltd, is a limited liability company providing healthcare services. The company is currently commissioning a private new-build hospital complete

More information

Data. X-ray Image Intensifier HIDEQ 23-3 ISP

Data. X-ray Image Intensifier HIDEQ 23-3 ISP Data X-ray Image Intensifier HIDEQ 23-3 ISP State-of-the-art Image Intensifier Technology HIDEQ 23-Mu Features and benefits HDQE cesium iodide input phosphor screen of very fine structure deposited on

More information

+ Human method is pattern recognition based upon multiple exposure to known samples.

+ Human method is pattern recognition based upon multiple exposure to known samples. Main content + Segmentation + Computer-aided detection + Data compression + Image facilities design + Human method is pattern recognition based upon multiple exposure to known samples. + We build up mental

More information

2012 Computed Tomography

2012 Computed Tomography 2012 Computed Tomography QUALITY CONTROL MANUAL Radiologist s Section Radiologic Technologist s Section Medical Physicist s Section 2012 Computed Tomography QUALITY CONTROL MANUAL Radiologist s Section

More information

FDA MAMMOSCAN FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM MAMMOGRAPHY

FDA MAMMOSCAN FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM MAMMOGRAPHY MAMMOGRAPHY MAMMOSCAN FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM Biopsy Attachment џ MAMMOSCAN is a digital scanning technology development taking a special place in ADANI Medical X-ray product line. џ Its

More information

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide Use of the Guide Carestream CR Systems are designed to meet international safety and performance standards. Personnel operating

More information

Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel:

Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel: Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel:+82-31-737-2211 Fax:+82-31-737-2210 Factory 236-4 Sangdaewon-dong, Seongnam-si,

More information

SEAMLESS INTEGRATION MULTIPLE SOLUTIONS ONE PRODUCT ONE COMPANY

SEAMLESS INTEGRATION MULTIPLE SOLUTIONS ONE PRODUCT ONE COMPANY SEAMLESS INTEGRATION ONE COMPANY ONE PRODUCT MULTIPLE SOLUTIONS SEAMLESS INTEGRATION ONE COMPANY - ONE PRODUCT - MULTIPLE SOLUTIONS Introduction As leaders in X-Ray Generator Technology we are utilizing

More information

Global Trade Medical Supplies

Global Trade Medical Supplies Features: Achieve Clarity True to the Source Data A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD

More information

Equipment Quality Control for Primary Displays June 5, Imaging Physics CancerCare Manitoba

Equipment Quality Control for Primary Displays June 5, Imaging Physics CancerCare Manitoba Equipment Quality Control for Primary Displays June 5, 2018 Imaging Physics CancerCare Manitoba Purpose An equipment quality control (QC) program establishes baseline performance levels, tracks system

More information

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria Nicholas B. Bevins, Ph.D. TG270 Co-chair Display Check 2 1 TG270 Goals Provide an update

More information

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria Nicholas B. Bevins, Ph.D. TG270 Co-chair Display Check 2 TG270 Goals Provide an update to

More information

The American College of Radiology Mammography Accreditation Program Screen-Film: Frequently Asked Questions (Updated: March 16, 2018)

The American College of Radiology Mammography Accreditation Program Screen-Film: Frequently Asked Questions (Updated: March 16, 2018) The American College of Radiology Mammography Accreditation Program Screen-Film: Frequently Asked Questions (Updated: March 16, 2018) Table of Contents ACR Mammography Accreditation... 1 The 1999 ACR Mammography

More information

Module 7. Video and Purchasing Components

Module 7. Video and Purchasing Components Module 7 Video and Purchasing Components Objectives 1. PC Hardware A.1.11 Evaluate video components and standards B.1.10 Evaluate monitors C.1.9 Evaluate and select appropriate components for a custom

More information

Understanding Multimedia - Basics

Understanding Multimedia - Basics Understanding Multimedia - Basics Joemon Jose Web page: http://www.dcs.gla.ac.uk/~jj/teaching/demms4 Wednesday, 9 th January 2008 Design and Evaluation of Multimedia Systems Lectures video as a medium

More information

Nio. Industry-standard diagnostic display systems

Nio. Industry-standard diagnostic display systems Nio Industry-standard diagnostic display systems Diagnostic confidence in grayscale With the Nio diagnostic display system, Barco brings dependable diagnostic imaging to its true potential. Presenting

More information

Colour Explosion Proof Video Camera USER MANUAL VID-C

Colour Explosion Proof Video Camera USER MANUAL VID-C Colour Explosion Proof Video Camera USER MANUAL VID-C Part Number: MAN-0036-00 Rev 4 Copyright 2002 Net Safety Monitoring Inc. Printed in Canada This manual is provided for informational purposes only.

More information

Breast Imaging Essentials

Breast Imaging Essentials Breast Imaging Essentials Module 10 Transcript 2016 ASRT. All rights reserved. Breast Imaging Essentials Module 10 Digital Breast Tomosynthesis 1. ASRT Animation 2. Welcome Welcome to Module 10 of Breast

More information

Intuitive Workflow by Barco. Designed for the way you work, naturally.

Intuitive Workflow by Barco. Designed for the way you work, naturally. Intuitive Workflow by Barco Designed for the way you work, naturally. As the volume and complexity of patient exams continue to grow, radiologists face increasing demands to boost their productivity. Many

More information

Guidelines for Quality Assurance in Radiation Protection for Diagnostic X-Ray Facilities: Large X-Ray Facilities

Guidelines for Quality Assurance in Radiation Protection for Diagnostic X-Ray Facilities: Large X-Ray Facilities Guidelines for Quality Assurance in Radiation Protection for Diagnostic X-Ray Facilities: Large X-Ray Facilities J L Poletti 1995/1 NRL Report GUIDELINES FOR QUALITY ASSURANCE IN RADIATION PROTECTION FOR

More information

V9A01 Solution Specification V0.1

V9A01 Solution Specification V0.1 V9A01 Solution Specification V0.1 CONTENTS V9A01 Solution Specification Section 1 Document Descriptions... 4 1.1 Version Descriptions... 4 1.2 Nomenclature of this Document... 4 Section 2 Solution Overview...

More information

Initial Experience With Automatic Image Transmission to an Intensive Care Unit Using Picture Archiving and Communications System Technology

Initial Experience With Automatic Image Transmission to an Intensive Care Unit Using Picture Archiving and Communications System Technology Initial Experience With Automatic Image Transmission to an Intensive Care Unit Using Picture Archiving and Communications System Technology Carl E. Ravin This report describes a refinement of the interaction

More information

Barco surgical displays. High-accuracy visualization solutions for surgery and endoscopy

Barco surgical displays. High-accuracy visualization solutions for surgery and endoscopy Barco surgical displays High-accuracy visualization solutions for surgery and endoscopy Near-patient surgical displays The complexity of general and minimally invasive surgery places high demands on technology

More information

QUALITY CONTROL AND PATIENT DOSES FROM X-RAY EXAMINATIONS IN SOME HOSPITALS IN THAILAND

QUALITY CONTROL AND PATIENT DOSES FROM X-RAY EXAMINATIONS IN SOME HOSPITALS IN THAILAND QUALITY CONTROL AND PATIENT DOSES FROM X-RAY EXAMINATIONS IN SOME HOSPITALS IN THAILAND P. Plainoi, W. Diswath, N. Manatrakul Ministry of Public Health, Nonthaburi, Thailand XA0101612 Abstract Quality

More information

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life. Ergonomic design packed with powerful performance MULTIMOBIL 5C Answers for life. MULTIMOBIL 5C Mobile C-arm image intensifier system with high frequency technology Siemens has led the way in development

More information

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS FOCUS ON FINE SOLUTIONS THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS Welding lasers from ROFIN ROFIN s laser sources for welding satisfy all criteria for the optimized laser

More information

JEFFERSON COLLEGE. Image Intensification & Equipment

JEFFERSON COLLEGE. Image Intensification & Equipment JEFFERSON COLLEGE COURSE SYLLABUS RAD175 Image Intensification & Equipment 3 Credit Hours Revised by: Janet E. Akers BS RT (R)(M) Date: October 3, 2013 Kenny Wilson, Director, Health Occupation Programs

More information

User Manual. Model 979T and 979R Digital Audio Converters

User Manual. Model 979T and 979R Digital Audio Converters User Manual Model 979T and 979R Digital Audio Converters Table Of Contents 1.0 Introduction....................... 3 2.0 Checking Package Contents............... 3 3.0 Installation........................

More information

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK NEMA Standards Publication XR 25-2010 Computed Tomography Dose Check Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite

More information

Coronis 5MP Mammo. The standard of care for digital mammography

Coronis 5MP Mammo. The standard of care for digital mammography Coronis 5MP Mammo The standard of care for digital mammography The standard of care For thousands of women every day, details make all the difference. This understanding, along with many years of commitment

More information

Optimizing the Workflow of Radiologists

Optimizing the Workflow of Radiologists Clinical Performance That Matters Optimizing the Workflow of Radiologists www.barcomedical.com Meeting the Challenges of Today s Reading Rooms Radiology has long been at the epicenter of healthcare, with

More information

Agilent 87075C Multiport Test Set Product Overview

Agilent 87075C Multiport Test Set Product Overview Agilent 87075C Multiport Test Set Product Overview A complete 75 ohm system for cable TV device manufacturers Now, focus on testing, not reconnecting! For use with the Agilent 8711 C-Series of network

More information

Radiology Physics Lectures: Computers. Associate Professor, Radiology x d

Radiology Physics Lectures: Computers. Associate Professor, Radiology x d COMPUTERS IN MEDICAL IMAGING David Hall, Ph.D. DABR Associate Professor, Radiology x20893 dhll@ djhall@ucsd.edud d 1 introduced into medical imaging in the early 1970 s essential to many modalities X-ray

More information

Understanding Compression Technologies for HD and Megapixel Surveillance

Understanding Compression Technologies for HD and Megapixel Surveillance When the security industry began the transition from using VHS tapes to hard disks for video surveillance storage, the question of how to compress and store video became a top consideration for video surveillance

More information

Mammo Tomosynthesis 5MP

Mammo Tomosynthesis 5MP Mammo Tomosynthesis 5MP Display system for digital breast imaging Approved for TOMOSYNTHESIS MAMMOGRAPHY The standard of care For thousands of women every day, details make all the difference. This understanding

More information

High Value-Added IT Display - Technical Development and Actual Products

High Value-Added IT Display - Technical Development and Actual Products High Value-Added IT Display - Technical Development and Actual Products ITAKURA Naoki, ITO Tadayuki, OOKOSHI Yoichiro, KANDA Satoshi, MUTO Hideaki Abstract The multi-display expands the desktop area to

More information

Radiography and Mammography Viewing Systems

Radiography and Mammography Viewing Systems Radiography and Mammography Viewing Systems For assistance contact your authorized RADX Dealer, or call S&S Technology at 800-231-1747 E-mail salessupport@radx.com www.ssxray.com Mammography Digital Viewing

More information

AWT150C/AWT150CS/ AWT151C CCD Camera

AWT150C/AWT150CS/ AWT151C CCD Camera AWT150C/AWT150CS/ AWT151C CCD Camera ISSUED OCTOBER 2018 WARNING Failure to follow all instructions and safety precautions in this manual, in the vehicle and body manufacturers' manuals and on the safety

More information

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions CAPTURE Add-on module for capturing images from analog video sources CAPTURE anything to DICOm VERSiON 1.2 Specialists in Medical Digital Imaging Solutions iq-capture Connect any medical device to your

More information

More Info at Open Access Database Process Control for Computed Tomography using Digital Detector Arrays

More Info at Open Access Database  Process Control for Computed Tomography using Digital Detector Arrays Digital Industrial Radiology and Computed Tomography (DIR 2015) 22-25 June 2015, Belgium, Ghent - www.ndt.net/app.dir2015 More Info at Open Access Database www.ndt.net/?id=18082 Process Control for Computed

More information

-Technical Specifications-

-Technical Specifications- Annex I to Contract 108733 NL-Petten: the delivery, installation, warranty and maintenance of one (1) X-ray computed tomography system at the JRC-IET -Technical Specifications- INTRODUCTION In the 7th

More information

Types of CRT Display Devices. DVST-Direct View Storage Tube

Types of CRT Display Devices. DVST-Direct View Storage Tube Examples of Computer Graphics Devices: CRT, EGA(Enhanced Graphic Adapter)/CGA/VGA/SVGA monitors, plotters, data matrix, laser printers, Films, flat panel devices, Video Digitizers, scanners, LCD Panels,

More information

User Guide. HDMI Active Cable Extender. DVI-7370c

User Guide. HDMI Active Cable Extender. DVI-7370c User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY STATEMENT........................ 1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE

More information

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c User Guide Single-Link DVI Active Cable Extender DVI-7171c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0

More information

2017 Computed Tomography

2017 Computed Tomography 2017 Computed Tomography QUALITY CONTROL MANUAL Radiologist s Section Radiologic Technologist s Section Qualified Medical Physicist s Section 2017 Computed Tomography QUALITY CONTROL MANUAL Radiologist

More information

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study: Case Study: Scalable Edge Enhancement Introduction Edge enhancement is a post processing for displaying radiologic images on the monitor to achieve as good visual quality as the film printing does. Edges

More information

CONTENTS. Section 1 Document Descriptions Purpose of this Document... 2

CONTENTS. Section 1 Document Descriptions Purpose of this Document... 2 CONTENTS Section 1 Document Descriptions... 2 1.1 Purpose of this Document... 2 1.2 Nomenclature of this Document... 2 Section 2 Solution Overview... 4 2.1 General Description... 4 2.2 Features and Functions...

More information

THE INTERNATIONAL REMOTE MONITORING PROJECT RESULTS OF THE SWEDISH NUCLEAR POWER FACILITY FIELD TRIAL

THE INTERNATIONAL REMOTE MONITORING PROJECT RESULTS OF THE SWEDISH NUCLEAR POWER FACILITY FIELD TRIAL L. 1 0 2 5 4 4 4 9 7545V8.C THE INTERNATIONAL REMOTE MONITORING PROJECT RESULTS OF THE SWEDISH NUCLEAR POWER FACILITY FIELD TRIAL C.S. Johnson Sandia National Laboratories Albuquerque, New Mexico USA OSTB

More information

Optical Engine Reference Design for DLP3010 Digital Micromirror Device

Optical Engine Reference Design for DLP3010 Digital Micromirror Device Application Report Optical Engine Reference Design for DLP3010 Digital Micromirror Device Zhongyan Sheng ABSTRACT This application note provides a reference design for an optical engine. The design features

More information

CHARLOTTE MECKLENBURG PUBLIC ACCESS CORPORATION

CHARLOTTE MECKLENBURG PUBLIC ACCESS CORPORATION CHARLOTTE MECKLENBURG PUBLIC ACCESS CORPORATION REGULATIONS & PROCEDURES A. MISSION STATEMENT Effective 12/19/18 1. Charlotte Mecklenburg Public Access Corporation (CMPAC) was created to manage and operate

More information

TANZANIA COMMUNICATIONS REGULATORY AUTHORITY

TANZANIA COMMUNICATIONS REGULATORY AUTHORITY ANNEX 10 THE UNITED REPUBLIC OF TANZANIA TANZANIA COMMUNICATIONS REGULATORY AUTHORITY FEES AND APPLICATION GUIDELINES FOR TELECOMMUNICATIONS/RADIOCOMMUNICATIONS EQUIPMENT TYPE APPROVAL COMMUNICATIONS EQUIPMENT

More information

ORDER FORM FOR SPECIALTY SERVICES OF MOVIE FILM RECOVERY AND SCANNING OF WARPED, SHRUNK OR DAMAGED FILM (Film in poor condition)

ORDER FORM FOR SPECIALTY SERVICES OF MOVIE FILM RECOVERY AND SCANNING OF WARPED, SHRUNK OR DAMAGED FILM (Film in poor condition) ORDER FORM FOR SPECIALTY SERVICES OF MOVIE FILM RECOVERY AND SCANNING OF WARPED, SHRUNK OR DAMAGED FILM (Film in poor condition) TEAMWORK MEDIA LAB 5662A Longbeach Rd. Nelson BC Canada V1L6N9 PHONE: 1-(250)

More information

Power Consumption Trends in Digital TVs produced since 2003

Power Consumption Trends in Digital TVs produced since 2003 Power Consumption Trends in Digital TVs produced since 2003 Prepared by Darrell J. King And Ratcharit Ponoum TIAX LLC 35 Hartwell Avenue Lexington, MA 02421 TIAX Reference No. D0543 for Consumer Electronics

More information

MX215. Your advantages. 2MP Medical-Display

MX215. Your advantages. 2MP Medical-Display MX215 Your advantages The EIZO MX215 features factory-preset DICOM tonal values and displays greyscale tones of radiological images in accordance with the requirements of the object. The advantage here

More information

Corrigendum-II. Up to 30 th October 2018 till 17:00 Hrs. 31 st October 2018 till 17:00 Hrs. 2 nd November 2018 till 14:00 Hrs.

Corrigendum-II. Up to 30 th October 2018 till 17:00 Hrs. 31 st October 2018 till 17:00 Hrs. 2 nd November 2018 till 14:00 Hrs. Bihar Medical Services & Infrastructure Corporation Limited 4 th floor State Building Construction Corporation Limited. Hospital Road, Shastri Nagar, Patna 800023, Phone/Fax: +91612 2283287,+ 91612 2283288

More information

Interaction of Infrared Controls And Fluorescent Lamp/Ballast Systems In Educational Facilities

Interaction of Infrared Controls And Fluorescent Lamp/Ballast Systems In Educational Facilities LSD 6-1999 A NEMA Lighting Systems Division Document Interaction of Infrared Controls And Fluorescent Lamp/Ballast Systems In Educational Facilities Prepared by Lamp Section Ballast Section National Electrical

More information

These are used for producing a narrow and sharply focus beam of electrons.

These are used for producing a narrow and sharply focus beam of electrons. CATHOD RAY TUBE (CRT) A CRT is an electronic tube designed to display electrical data. The basic CRT consists of four major components. 1. Electron Gun 2. Focussing & Accelerating Anodes 3. Horizontal

More information

Creating room. for your visions

Creating room. for your visions BuckyDiagnost Radiography solutions Creating room for your visions 2 What makes a Rad Room simply perfect? Room for all your ideas Efficient, powerful, individual and innovative. This sums up just some

More information

Multi-Format AV Scaler with DisplayPort

Multi-Format AV Scaler with DisplayPort AVSC-7DA-HDMI Product Data Sheet Multi-Format AV Scaler with DisplayPort Basic Features Compliant with HDCP 2.0. Input support: Analog: analog video, S-Video, composite video, VGA; Digital: DVI, HDMI,

More information

Technologist Quality Control Procedures

Technologist Quality Control Procedures Technologist Quality Control Procedures The specific procedures for the Technologist Quality Control Program are those specified in the most current ACR MRI QC Manual. WEEKLY MRI EQUIPMENT QUALITY CONTROL

More information

MX215. Your advantages. 2MP Medical-Display

MX215. Your advantages. 2MP Medical-Display MX215 Your advantages The EIZO MX215 features factory-preset DICOM tonal values and displays greyscale tones of radiological images in accordance with the requirements of the object. The advantage here

More information

VideoSplitter HDMI 4K PT

VideoSplitter HDMI 4K PT VideoSplitter HDMI 4K PT 4K HDMI Splitter Pigtail Type Installation and Operation Manual 10707 Stancliff Road Houston, Texas 77099 Phone: (281) 933-7673 tech-support@rose.com LIMITED WARRANTY Rose Electronics

More information

Just plug and go. Practical Features. Valuable Benefits

Just plug and go. Practical Features. Valuable Benefits Just plug and go Practical Features 12-inch adjustable monitor On-screen measurement in varied orientations Simple image capture directly from screen to USB stick or internal hard drive Touch-screen virtual

More information

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology High Frequency X-Ray Technology Wide Screen Control with Touch-Technology The Q-VISION HF Series TM The Q-VISION Series TM integrates innovative high frequency design along with superb functionality, resulting

More information

CrystalView DVI Micro-DL Extender

CrystalView DVI Micro-DL Extender CrystalView DVI Micro-DL Extender Quick Start Guide CrystalView DVI Micro Dual-Link Fiber Extender Rose Electronics 10707 Stancliff Road Houston, Texas 77099 Phone (281) 9337673 Limited Warranty Rose Electronics

More information

Evaluation report. Eizo RadiForce G33-N 3MP greyscale flat panel liquid crystal display (LCD) CEP 07003

Evaluation report. Eizo RadiForce G33-N 3MP greyscale flat panel liquid crystal display (LCD) CEP 07003 Evaluation report Eizo RadiForce G33-N 3MP greyscale flat panel liquid crystal display (LCD) CEP 07003 August 2007 Contents 2 Executive summary... 3 Introduction... 5 Product description... 6 Evaluation

More information

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR 28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. TABLE OF CONTENTS 1, General information...

More information

Coronis Fusion multi-modality displays. The ultimate in diagnostic flexibility

Coronis Fusion multi-modality displays. The ultimate in diagnostic flexibility Coronis Fusion multi-modality displays The ultimate in diagnostic flexibility The ultimate in diagnostic flexibility Radiology reading rooms are fast becoming one of the busiest departments in the healthcare

More information

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura Vascular Development of Trinias FPD-Equipped Angiography System Medical Systems Division, Shimadzu Corporation Yoshiaki Miura 1. Introduction Shimadzu has developed Trinias (one ceiling-mounted type C12

More information

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D User Manual HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D Model 1180T Transmitter Model 1180R Receiver Model 1180TD Transmitter Model 1180RD Receiver WARNINGS Read these

More information

Tele-Medicine Focusing on the future. Image and data ar Seize the

Tele-Medicine Focusing on the future. Image and data ar Seize the Image1 digital v 100% digita With the interdisciplinary IMAGE1 camera, image information is digitalized directly on the CCD sensor at the earliest possible point in time. Thanks to the unique DSS technology

More information

Elements of a Television System

Elements of a Television System 1 Elements of a Television System 1 Elements of a Television System The fundamental aim of a television system is to extend the sense of sight beyond its natural limits, along with the sound associated

More information

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration (Choice s experience) Installation and configuration (cont.) (Choice s experience) DOCSIS 3.0 Components M-CMTS deployment DTI Server Edge QAM Modular CMTS I-CMTS Integrated CMTS Integrated DOCSIS 3.0

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUAL Table of Contents Safety Information. 2 Specifications.. 3 Product Overview 4 Power & Signal Connection... 6 Installation... 7 Rigging the Fixture.2 Service...2 Maintenance.3 Parts List...

More information

Technology White Paper Plasma Displays. NEC Technologies Visual Systems Division

Technology White Paper Plasma Displays. NEC Technologies Visual Systems Division Technology White Paper Plasma Displays NEC Technologies Visual Systems Division May 1998 1 What is a Color Plasma Display Panel? The term Plasma refers to a flat panel display technology that utilizes

More information

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL Full HD Widescreen LED Monitor L215ADS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

User Manual. Model 1351 DVI Repeater with HDCP

User Manual. Model 1351 DVI Repeater with HDCP User Manual Model 1351 DVI Repeater with HDCP 2 Table Of Contents 1.0 Introduction....................... 4 2.0 Specifications...................... 5 3.0 Checking Package Contents............... 7 4.0

More information

Monitor and Display Adapters UNIT 4

Monitor and Display Adapters UNIT 4 Monitor and Display Adapters UNIT 4 TOPIC TO BE COVERED: 4.1: video Basics(CRT Parameters) 4.2: VGA monitors 4.3: Digital Display Technology- Thin Film Displays, Liquid Crystal Displays, Plasma Displays

More information

Dental Line. High frequency intraoral x-ray unit. radiology ahead

Dental Line. High frequency intraoral x-ray unit. radiology ahead Dental Line High frequency intraoral x-ray unit radiology ahead enhance your operating process Hi-frequency generator, for shorter exposures and reduced dose Wireless X-ray pushbutton, available for ultimate

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E USER MANUAL 27 Full HD Widescreen LED Monitor L270E TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

LASER DIODE NX8346TS nm AlGaInAs MQW-DFB LASER DIODE FOR 10 Gb/s APPLICATION DESCRIPTION APPLICATIONS FEATURES

LASER DIODE NX8346TS nm AlGaInAs MQW-DFB LASER DIODE FOR 10 Gb/s APPLICATION DESCRIPTION APPLICATIONS FEATURES LASER DIODE NX8346TS 1 310 nm AlGaInAs MQW-DFB LASER DIODE FOR 10 Gb/s APPLICATION DESCRIPTION The NX8346TS is a 1 310 nm Multiple Quantum Well (MQW) structured Distributed Feed-Back (DFB) laser diode

More information

USER MANUAL Full HD Widescreen LED Monitor L215IPS

USER MANUAL Full HD Widescreen LED Monitor L215IPS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215IPS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information