Polytec Scanning Vibrometer PSV-300

Size: px
Start display at page:

Download "Polytec Scanning Vibrometer PSV-300"

Transcription

1 Polytec Scanning Vibrometer PSV-300 Principle of Operation and Applications This Powerpoint presentation informs you about operation of the Polytec s Scanning Vibrometer PSV-300 and presents some typical measurements carried out in the automotive industry. As this material contains several AVI movie files a fast CD ROM is recommended for viewing.

2 Polytec Scanning Vibrometer PSV-300 Basic Configuration of a Scanning Vibrometer The PSV-300 comprises an optical scanning head incorporating the laser interferometer sensor, beam steering optics and a video camera. Data from the scanning head are processed by the OFV-3001 vibrometer controller. A Windows NT workstation is responsible for scan point definition, data acquisition and control of the entire system. Sensor Head OFV-056 Test object Scan Electronics Video Vibrometer Sensor OFV-303 Scanning Mirrors Vibrometer Controller OFV-3001 Data Management System with NT Workstation

3 Polytec Scanning Vibrometer PSV-300 The OFV-056 Sensor Head features: Scan angle 40 x 40 degrees with 0.02 degrees resolution. Important feature for measurements of large objects in limited space areas 72 x zoom color video camera for measuring large and/or small objects without re-positioning the sensor head. Video camera, laser focus, range settings: All remote controlled for easy operation, e.g. with the scan head installed in an engine test chamber. Large range of working distance 0.2 m to > 50 m Coaxial attachment for scanning small objects down to 1 x 1 mm, e.g. injector nozzles

4 Polytec Scanning Vibrometer PSV-300 PSV-300-H Data Management System designed for the specific needs of our automotive customers 6 velocity ranges up to 10 m/s. Important for measurements on tires, shafts and other rotating parts. 4 channel data acquisition with 80 khz bandwidth. Up to 3 reference channels are recorded together with the vibrometer data. Full remote control of all hardware Scanning speed up to 100 points per second, reducing the brake squeal measurement time Build-in multiple channel signal generator Optional order tracking software for run-up measurements.

5 Polytec Scanning Vibrometer PSV-300 Making a PSV measurement On the following pages we will demonstrate how easy a PSV measurement is set-up and carried out. The experienced PSV user may use our new Visual Basic Macro feature to generate his own macros for automation of the entire measurement routine. Define Scan Area Adjust Parameters Select Scan Mode Scan Select Frequency Bands Presentation of Data Export

6 Polytec Scanning Vibrometer PSV-300 Define Scan Area Adjust Parameters Select Scan Mode Scan Select Frequency Bands Presentation of Data Export Like in a drawing program the user defines the scan points on the structure. Different objects may have different types of meshes and mesh densities. Single points can be defined as well as lines of points (e.g. for scanning a drive shaft) with densities up to 512 x 512 points per object! The laser beam is clearly visible on screen and perfectly matching with the scan points in the video image.

7 Polytec Scanning Vibrometer PSV-300 Define Scan Area Adjust Parameters Select Scan Mode Scan Select Frequency Bands Presentation of Data Export If you have ever used an FFT analyzer the selection of acquisition parameters will be self explaining. The PSV data acquisition features Zoom- FFT, time domain data storage and FastScan for single frequency measurements (e.g. brake noise). In Multi Frame Mode the vibration data are synchronized with the engine and scanning results may be displayed for each cylinder separately.

8 Polytec Scanning Vibrometer PSV-300 Define Scan Area Adjust Parameters Select Scan Mode Scan Select Frequency Bands Presentation of Data Export During the scan the data quality is verified for each point. The Signal Enhancement algorithm will automatically increase the number of averages for points with low SNR. Data with too low SNR are rejected or re-measured resulting in perfectly clean measurement data. If you are using modal analysis software you will appreciate the high quality of the PSV-300 data.

9 Polytec Scanning Vibrometer PSV-300 Define Scan Area Adjust Parameters Select Scan Mode Scan Select Frequency Bands Export After the scan is finished the power spectrum is shown either averaged over all scan points or for individual data points. The user selects frequencies (modes) of interest for the on screen presentation of the results. Data can be presented for the entire frequency band (rms), for selected frequency bands (rms) or for individual frequencies.

10 Polytec Scanning Vibrometer PSV-300 Define Scan Area Adjust Parameters Select Scan Mode Scan Data are presented in 2-D color coded, 3-D mesh or isoline displays. Even the video image of the test object may be animated. Presentation of Data Export

11 Polytec Scanning Vibrometer PSV-300 Define Scan Area Adjust Parameters Select Scan Mode Scan Select Frequency Bands Presentation of Data Export For the vibrometer and all 3 reference channels the the complex spectra are saved to hard disc during the scan. The Universal File Format (UFF) option allows easy export of these data to all common modal analysis programs.

12 Polytec Scanning Vibrometer PSV-300 Selected Automotive Applications On the following pages we present some examples of automotive measurements carried out with the PSV system. Please note that the list of applications mentioned here is not complete. Many of our customers applications are confidential and cannot be discussed in this presentation. If you have questions about your particular application please do not hesitate to contact Polytec for more information.

13 Polytec Scanning Vibrometer PSV-300 Panel vibration on doors, bonnet and inside of the vehicle Vibration testing on panels is a classical PSV applications in the automotive industry. The panels are excited either by mounting onto a shaker, by rolling road or by mounting the entire vehicle onto a shaker system. This application includes also tests inside of the car such as on the dashboard or on the car seats.

14 PSV-300 for panel vibrations The animation shows the color coded vibration of the bonnet at 103 Hz. Green data areas are standing for negative and red areas for positive velocities. The data are super-imposed to the video image. The bonnet (0.7 mm sheet metal) is supported by beams which can resonate like organ pipes. Stoppers are placed into the beams for closing open cavities. The PSV helps to identify the best location for these stoppers. Furthermore the effects of additional dumping materials is studied. In this measurement the bonnet is freely suspended and excited by a set of loudspeakers. A period chirp signal generated by the PSV-300 is applied to the loudspeakers for simultaneous excitation of the entire frequency band.

15 PSV-300 for panel vibrations Same measurement on a bonnet, but data shown at 153 Hz. The animation of the video image provides an easy understanding of how a structure is vibrating.

16 PSV-300 for panel vibrations In some experiments vibration measurements are carried out on objects excited by their own running engine. A once per revolution trigger pulse from the engine may be acquired simultaneously by the PSV system for synchronization of the data. The vibration of the rear part of the car is shown at 2 different frequencies. In the lower case the video image itself with super-imposed measurement data is animated.

17 PSV-300 for panel vibrations Bonnet vibration of the new VW Beetle car. For these measurements the vehicle was mounted onto shakers and excited by a periodic chirp signal.

18 PSV-300 for panel vibrations Vibration measurements on car doors are a traditional application for Polytec scanning vibrometers. Best results are achieved on a freely suspended door coupled to a vibration shaker as shown on the left.

19 PSV-300 for panel vibrations Measurements on the dashboard as shown above are routinely performed with the PSV-300. In above example the dashboard is mounted to a vibration shaker. The customer had problems to identify the source of vibrations on the glove box. The PSV helped to locate a part (dumper) behind the glove box causing the unwanted vibrations.

20 PSV-300 for panel vibrations From time to time measurements on highly reflecting parts (mirrors) or on windows are requested. Such measurements require a special surface treatment as otherwise the PSV would not receive any return signal. Polytec provides a special spray (powder) for scattering enhancement which can easily be removed after the measurement without any damage to the surface.

21 Polytec Scanning Vibrometer PSV-300 Vibration Testing of Braking Systems All major brake manufacturers are using Polytec vibrometer systems for measurements of brake noise, squeal and modal testing. This includes not only the Scanning Vibrometer, but also the Polytec 3-D vibrometer and fiber optical systems. For more details about brake testing please refer to the other presentation on this CD prepared by our customer Bosch.

22 PSV-300 for brake testing PSV-300 measurements on a test stand for brake pads. Data for used and new pads are acquired and compared to each other. During the scan the brake disc is slowly rotating.

23 PSV-300 for brake testing Deflection shape of brake disc under squeal condition. The squeal appears once per revolution and may disappear once the brake is running hot. Polytec provides an acoustical trigger unit comprising a microphone, DSP filter and gate unit. With this trigger unit the scan is paused while no squeal is present. As the squeal appears at single frequencies FastScan mode with scan speeds of up to 100 points per second is normally used for this kind of measurements.

24 PSV-300 for brake testing In most measurements the brake disc is mounted to a brake dynamometer. In above example the brake was driven by the tire running on the rolling road. Optical access was very difficult to achieve and only possible via mirrors. The Polytec trigger unit with microphone was used to synchronize the scan with the brake squeal.

25 Polytec Scanning Vibrometer PSV-300 Vibration Testing on Rotating Systems Many automotive measurements are performed on moving surfaces such as brakes, tires, pulleys, fan belts etc. Such tests are only possible with non-contact methods like laser vibrometry. While scanning the vibrometer will not only see the vibrational out-ofplane, but also the DC in-plane velocity component. Here the high velocity capability of the PSV-300 (10 m/s) is an important feature. A system with lower velocity limit would easily go into saturation when the scan angle, i.e. the DC velocity component increases.

26 PSV-300 for rotating objects Axial vibration measurements on an engine pulley and on an alternator. For such measurements a once per revolution signal from the engine is frequently used for triggering the data acquisition. An accelerometer on the engine/alternator provides a phase reference for the PSV data. The PSV can acquire up to 3 reference signals simultaneously.

27 PSV-300 for rotating objects Although in these examples the tires are mounted to a shaker and non-rotating, measurements on rotating tires are a major application for Polytec Vibrometers. Engineers at leading tire manufacturing companies are using the PSV-300 for modal testing on stationary tires and ODS measurements on rotating tires. Tire measurements are a demanding application requiring a high velocity capability of the laser vibrometer as the circumferential velocity of the tire might otherwise saturate the vibrometer system.

28 Polytec Scanning Vibrometer PSV-300 Vibration Testing for other automotive applications Not all applications of the PSV in the automotive industry can be addressed in this presentation. Measurements on engine components, testing in wind tunnels, exhaust systems, car seats and even measurements on all the electrical motors of a vehicle are other popular applications. In addition some applications require non-scanning vibrometers, e.g. valve train testing on engines, common rail injection nozzles and more.

29 PSV-300 for other automotive applications Above animation prsents data measured on a yellow glowing hot exhaust system. Even if surface temperatures are approaching 900 C no special precautions are needed. For exhaust measurements frequently a PSV-300 and a single point vibrometer are combined. One for scanning the exhaust and the other as a stationary reference. The reference vibrometer is fully remote controlled by the PSV software as well.

30 PSV-300 for other automotive applications A large portion of all PSV systems are used by suppliers of automotive components and not by the motor companies themselves. The images are showing an inlet manifold made of plastics. The manufacturer of these plastics parts is routinely using PSV systems for achieving data for their modal analysis workstation.

31 Polytec Scanning Vibrometer PSV-300 Vibration Testing on large structures The PSV-300 system can be used for measurements on untreated surfaces for distances exceeding 20 m. Hence the PSV is capable of scanning large structures such as complete cars or even trucks. In some situations the scattering properties are too poor and surface enhancement is required, e.g. on very reflective paints, when measuring via poor quality mirrors etc. The next example shows that even if surface preparation is required a huge amount of time will be saved by using the PSV.

32 PSV-300 for large structures Measurement on a 20 m wide rail way wagon from ca. 20 m distance. The set-up for a large truck or bus would be similar. Instead of using powder spray for enhancing the scattering properties of the surface a total of 700 reflective marks was attached. Preparation of the measurement took ca. 3 hours, the measurement itself less than 10 minutes. When using conventional accelerometers time needed for the preparation of the test was more than 1 week.

33 Measurement of turbine blade vibrations. Experimental setup and scan grid on the A320 wheel

34 Jet Engines

35 Inflatable 4x6-meter communications antenna concept.

36 Squealing Brakes Three views of a deflection shape of a brake disk

37 New Method for Non-destructive Testing of Materials and Structures using Non-linear Acoustics Higher harmonics (40 khz excitation) at a simulated defect: Delamination in carbon fibre reinforced plastics (CFRP) Flaw detection in aluminum: 4th Harmonic (excitation frequency 20 khz)

38 3D animation and time trace of Input Shaped step response MEMS Accelerometer spring elbow at 23 khz

39 Bending mode of HGA at 5114 Hz Torsion mode of HGA at 6650 Hz Applications to Data Storage Dynamics

40 Laser Doppler Vibrometry Brings Insight into the Functioning of Fruit Fly Ears

41 Loudspeaker Development The Balanced Mode Radiator is a new approach to loudspeaker design with unique visual and acoustic features. Tight control of the membrane properties is essential to providing proper acoustic fidelity from the device. Polytec s Scanning Vibrometer enabled insitu measurements on operating devices with no contact or loading of the panel membrane, successfully accelerating the development and manufacturability of the new Sounds Good Vibration Analysis is a Valuable Tool for Loudspeaker Development loudspeaker k On-axis SPL [db] SPL 2k 3k 4k 5k 6k 7k 10k 20k 30k 40k 50k Frequency [Hz] Release Sample Golden Sample Fig. 1: On-axis Sound Pressure Level (SPL) spectra from tested BMR s. Introduction The Balanced Mode Radiator (BMR) represents a new class of loudspeaker with distinct design features and acoustical properties that distinguish it from the traditional, well-known electrodynamic loudspeaker design based on conical membranes. The most obvious difference between traditional conical speakers and the BMR is the use of a suspended flat circular disc as the radiating membrane panel (see title image). The drive unit features a clean appearance and a plane front that allows for innovative industrial designs with unique sound properties. Acoustically, the BMR is designed as full-range driver which supports almost the entire audible spectrum. For frequencies above the panel s first eigenmode, the BMR operates as a bending-wave device where its acoustic behavior is predominantly determined by the panel s mass density, bending stiffness, damping, and shear. These parameters are of paramount importance for the acoustic performance of the BMR. From Prototype to Mass Production The design of the BMR was done in Germany. But, due to cost constraints in the consumer market, most drive units had to be manufactured in China. During the product development phase, all required parts were tooled and made in China then assembled and tested in Germany. Each part s geometry and material was changed until satisfactory performance was achieved. A construction manual was written and sent to China together with the final drive unit. This Gold Standard called Golden Sample serves as a reference when setting up the production line. An initial set of prototype drive units known as Release Samples were sent back to Germany for approval. In the case study presented here, unexpected changes in the panel s material composition degraded the acoustic performance. A Release Sample was found to produce a less bright sound than the Gold Standard, although both units were built according to the same nominal specifications. Thus, the task was to identify the source of this difference. On-axis Frequency Response To begin the drive unit assessment, the acoustic on-axis frequency response was measured (Fig. 1). Above 18 khz the Release Sample is slightly louder than the Gold Standard, indicating a somewhat brighter sound. This measured result was the opposite of what was subjectively noted when auditioning both units k Averaged velocity & acceleration spectrum Velocity [mm/s] Acceleration Release Sample Golden Sample Velocity Release Sample Golden Sample Acceleration [m/s 2 ] 2k 3k 4k 5k 6k 8k 10k 20k 30k 40k 50k Frequency (Hz) Fig. 2: Average velocity and acceleration spectra from tested BMR panels Source: Polytec InFocus 1/2008 Polytec GmbH

42 Consequently, the next step was to try to resolve this apparent contradiction by spatially measuring the dynamic response of the BMR panels of both units using the Scanning Vibrometer. Vibration Analysis of Drive Units Vibration analysis was performed using a Polytec PSV-300 Scanning Vibrometer. For sample excitation, the vibrometer generated a swept sine wave signal ranging from 150 Hz to 50 khz, and acquired the velocity frequency response data from 1781 measurement points that were evenly distributed in a circular symmetric mesh across the panel. The average spectrum calculated using the Scanning Vibrometer software allowed quick access to mean velocity and mean acceleration data. In Fig. 2, the acceleration spectra of both units are plotted in Fig. 3: Out-of-plane deflection shapes for BMR panels at 10 khz, Release Sample (left), Gold Standard (right). the upper half of the diagram with the associated ordinate axis positioned to the right, while the velocity spectra are located in the lower half with the associated ordinate axis to the left. The most obvious deviations occur in the 7 12 khz range as opposed to the khz range identified by the on-axis Sound Pressure Level (SPL) measurements. Differences in this frequency range (7 12 khz) are more likely to be judged as bright or dull. The brighter sounding Gold Standard shows higher activity in both average spectra than the Release Sample, supporting the results of the informal subjective evaluation. Modal Analysis The results shown in Fig. 2 suggest that the two drive units have different panel materials. In Fig. 3, the operational deflection shapes (ODS) at 10 khz are compared. It is obvious that the Release Sample shows a bending mode with circular symmetry on its panel (left) while the Gold Standard features rotationally symmetric structures that break circular symmetry (right). The results confirm the previous findings. The Gold Standard BMR panel shows a much less isotropic bending stiffness than the Release Sample panel. Obviously, the panel manufacturer had actually tried to improve the panel quality by making it more isotropic. Release sample 10 khz velocity profile Momentary value [um/s ] GoldenSample 10kHz velocity profile Momentary value [um/s ] Conclusions Structural response data taken with Polytec s Scanning Vibrometer allowed in-situ identification and characterization of dynamic material properties in loudspeakers and clarified inconsistent preliminary SPL measurements and auditory tests. The net result of the vibration analysis was an improved understanding of the BMR and reduced development time by eliminating trial-and-error approaches raidal position [mm] Release Sample: axis Release Sample: axis Fig. 4: Plots of orthogonal cuts through Fig. 3 deflection shapes, Release Sample (left), Gold Standard (right) raidal position [mm] Golden Sample: 0 -axis Golden Sample: 90 -axis Authors Contact Dipl.-Ing. Charalampos Ferekidis, Karl-Heinz Fink Fink Audio Consulting, Essen, Germany; AudioPlus, Sutton SM1 2SG, UK lampos@ferekidis.de; karl-heinz@fink-audio.com Source: Polytec InFocus 1/2008 Polytec GmbH

Digital SWIR Scanning Laser Doppler Vibrometer

Digital SWIR Scanning Laser Doppler Vibrometer Digital SWIR Scanning Laser Doppler Vibrometer Scan-Series OptoMET Scanning SWIR Laser Doppler Vibrometer (SLDV) is used for non-contact measurement, visualization and analysis of structural vibrations.

More information

Digital SWIR Scanning Laser Doppler Vibrometer

Digital SWIR Scanning Laser Doppler Vibrometer Digital SWIR Scanning Laser Doppler Vibrometer Scan-Series OptoMET Scanning SWIR Laser Doppler Vibrometer (SLDV) is used for non-contact measurement, visualization and analysis of structural vibrations.

More information

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time HEAD Ebertstraße 30a 52134 Herzogenrath Tel.: +49 2407 577-0 Fax: +49 2407 577-99 email: info@head-acoustics.de Web: www.head-acoustics.de Data Datenblatt Sheet HEAD VISOR (Code 7500ff) System for online

More information

Laser measurements in the motor bearing diagnostics. Ariel Dzwonkowski 1, Leon Swędrowski 2

Laser measurements in the motor bearing diagnostics. Ariel Dzwonkowski 1, Leon Swędrowski 2 Laser measurements in the motor bearing diagnostics Ariel Dzwonkowski 1, Leon Swędrowski 2 1 Faculty of Electrical and Control Engineering, Gdansk University of Technology, Narutowicza 11/12 Str., Gdansk,

More information

Getting Started with the LabVIEW Sound and Vibration Toolkit

Getting Started with the LabVIEW Sound and Vibration Toolkit 1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool

More information

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS LVM-4000 LASER VALVE MOTION measurement system OH-1000 LASER VIBROMETER HEAD LASER-BASED TECHNOLOGY SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS ENGINE HEAD VIBRATION

More information

EngineDiag. The Reciprocating Machines Diagnostics Module. Introduction DATASHEET

EngineDiag. The Reciprocating Machines Diagnostics Module. Introduction DATASHEET EngineDiag DATASHEET The Reciprocating Machines Diagnostics Module Introduction Reciprocating machines are complex installations and generate specific vibration signatures. Dedicated tools associating

More information

EngineDiag. The Reciprocating Machines Diagnostics Module. Introduction DATASHEET

EngineDiag. The Reciprocating Machines Diagnostics Module. Introduction DATASHEET EngineDiag DATASHEET The Reciprocating Machines Diagnostics Module Introduction Industries Fig1: Diesel engine cylinder blocks Machines Reciprocating machines are complex installations and generate specific

More information

FLOW INDUCED NOISE REDUCTION TECHNIQUES FOR MICROPHONES IN LOW SPEED WIND TUNNELS

FLOW INDUCED NOISE REDUCTION TECHNIQUES FOR MICROPHONES IN LOW SPEED WIND TUNNELS SENSORS FOR RESEARCH & DEVELOPMENT WHITE PAPER #42 FLOW INDUCED NOISE REDUCTION TECHNIQUES FOR MICROPHONES IN LOW SPEED WIND TUNNELS Written By Dr. Andrew R. Barnard, INCE Bd. Cert., Assistant Professor

More information

MSV-400 Microscope Scanning Vibrometer

MSV-400 Microscope Scanning Vibrometer MSV-400 Microscope Scanning Vibrometer POLYTEC MICROSCOPE SYSTEMS MSV-050 Manual Microscope Adapter MSV-100 Remote Controlled Microscope Adapter MSV-400 Microscope Scanning Vibrometer PMA-400 Planar Motion

More information

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR Introduction: The RMA package is a PC-based system which operates with PUMA and COUGAR hardware to

More information

DESIGNING OPTIMIZED MICROPHONE BEAMFORMERS

DESIGNING OPTIMIZED MICROPHONE BEAMFORMERS 3235 Kifer Rd. Suite 100 Santa Clara, CA 95051 www.dspconcepts.com DESIGNING OPTIMIZED MICROPHONE BEAMFORMERS Our previous paper, Fundamentals of Voice UI, explained the algorithms and processes required

More information

Standard Operating Procedure of nanoir2-s

Standard Operating Procedure of nanoir2-s Standard Operating Procedure of nanoir2-s The Anasys nanoir2 system is the AFM-based nanoscale infrared (IR) spectrometer, which has a patented technique based on photothermal induced resonance (PTIR),

More information

The Removal of Speckle Noise from Torsional Laser Doppler Vibrometer Signals in Machine Health Monitoring

The Removal of Speckle Noise from Torsional Laser Doppler Vibrometer Signals in Machine Health Monitoring 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa The Removal of Speckle Noise from Torsional Laser Doppler Vibrometer Signals in Machine Health Monitoring Abrie J.

More information

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING R.H. Pawelletz, E. Eufrasio, Vallourec & Mannesmann do Brazil, Belo Horizonte, Brazil; B. M. Bisiaux,

More information

Torsional vibration analysis in ArtemiS SUITE 1

Torsional vibration analysis in ArtemiS SUITE 1 02/18 in ArtemiS SUITE 1 Introduction 1 Revolution speed information as a separate analog channel 1 Revolution speed information as a digital pulse channel 2 Proceeding and general notes 3 Application

More information

Transporting NV Standardized Testing from the Lab to the Production Environment

Transporting NV Standardized Testing from the Lab to the Production Environment 2009-01-2158 Transporting NV Standardized Testing from the Lab to the Production Environment G. Pietila and P. Goodes Sound Answers Copyright 2009 SAE International ABSTRACT NVH labs at Tier 1 and Tier

More information

In-process inspection: Inspector technology and concept

In-process inspection: Inspector technology and concept Inspector In-process inspection: Inspector technology and concept Need to inspect a part during production or the final result? The Inspector system provides a quick and efficient method to interface a

More information

Acoustical Noise Problems in Production Test of Electro Acoustical Units and Electronic Cabinets

Acoustical Noise Problems in Production Test of Electro Acoustical Units and Electronic Cabinets Acoustical Noise Problems in Production Test of Electro Acoustical Units and Electronic Cabinets Birger Schneider National Instruments Engineering ApS, Denmark A National Instruments Company 1 Presentation

More information

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it! Laser Beam Analyser Laser Diagnos c System If you can measure it, you can control it! Introduc on to Laser Beam Analysis In industrial -, medical - and laboratory applications using CO 2 and YAG lasers,

More information

THE DIGITAL DELAY ADVANTAGE A guide to using Digital Delays. Synchronize loudspeakers Eliminate comb filter distortion Align acoustic image.

THE DIGITAL DELAY ADVANTAGE A guide to using Digital Delays. Synchronize loudspeakers Eliminate comb filter distortion Align acoustic image. THE DIGITAL DELAY ADVANTAGE A guide to using Digital Delays Synchronize loudspeakers Eliminate comb filter distortion Align acoustic image Contents THE DIGITAL DELAY ADVANTAGE...1 - Why Digital Delays?...

More information

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications Durham Magneto Optics Ltd NanoMOKE 3 Wafer Mapper Specifications Overview The NanoMOKE 3 Wafer Mapper is an ultrahigh sensitivity Kerr effect magnetometer specially configured for measuring magnetic hysteresis

More information

A PSYCHOACOUSTICAL INVESTIGATION INTO THE EFFECT OF WALL MATERIAL ON THE SOUND PRODUCED BY LIP-REED INSTRUMENTS

A PSYCHOACOUSTICAL INVESTIGATION INTO THE EFFECT OF WALL MATERIAL ON THE SOUND PRODUCED BY LIP-REED INSTRUMENTS A PSYCHOACOUSTICAL INVESTIGATION INTO THE EFFECT OF WALL MATERIAL ON THE SOUND PRODUCED BY LIP-REED INSTRUMENTS JW Whitehouse D.D.E.M., The Open University, Milton Keynes, MK7 6AA, United Kingdom DB Sharp

More information

PSV-500 Scanning Vibrometer Full-fieldVibrationMeasurement Datasheet. PSV-500 Scanning Vibrometer

PSV-500 Scanning Vibrometer Full-fieldVibrationMeasurement Datasheet. PSV-500 Scanning Vibrometer PSV-500 Vibrometer PolytecVibrometersarestate-of-the-artfor noiseandvibrationmeasurementinresearchand development.theydetermineoperationaldeflection shapesandeigenmodesfornvh,acoustics,structural dynamics,ultrasonicsandfemvalidation.thehigh

More information

Virtual Vibration Analyzer

Virtual Vibration Analyzer Virtual Vibration Analyzer Vibration/industrial systems LabVIEW DAQ by Ricardo Jaramillo, Manager, Ricardo Jaramillo y Cía; Daniel Jaramillo, Engineering Assistant, Ricardo Jaramillo y Cía The Challenge:

More information

Concept of Operations (CONOPS)

Concept of Operations (CONOPS) PRODUCT 0-6873-P1 TxDOT PROJECT NUMBER 0-6873 Concept of Operations (CONOPS) Jorge A. Prozzi Christian Claudel Andre Smit Praveen Pasupathy Hao Liu Ambika Verma June 2016; Published March 2017 http://library.ctr.utexas.edu/ctr-publications/0-6873-p1.pdf

More information

Modal Testing of a Soprano pan using a 3D Laser Doppler Vibrometer

Modal Testing of a Soprano pan using a 3D Laser Doppler Vibrometer Technical Paper Modal Testing of a Soprano pan using a 3D Laser Doppler Vibrometer S.E. Maloney sem73@cam.ac.uk, Department of Engineering, University of Cambridge R. Traynor, roger@lambdaphoto.co.uk Lambda

More information

White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle. Introduction and Background:

White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle. Introduction and Background: White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle Introduction and Background: Although a loudspeaker may measure flat on-axis under anechoic conditions,

More information

Pre-processing of revolution speed data in ArtemiS SUITE 1

Pre-processing of revolution speed data in ArtemiS SUITE 1 03/18 in ArtemiS SUITE 1 Introduction 1 TTL logic 2 Sources of error in pulse data acquisition 3 Processing of trigger signals 5 Revolution speed acquisition with complex pulse patterns 7 Introduction

More information

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV

Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV Product: R&S UPV Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV Application Note 1GA47_0E This application note explains how to use acoustic calibrations

More information

Measurement of overtone frequencies of a toy piano and perception of its pitch

Measurement of overtone frequencies of a toy piano and perception of its pitch Measurement of overtone frequencies of a toy piano and perception of its pitch PACS: 43.75.Mn ABSTRACT Akira Nishimura Department of Media and Cultural Studies, Tokyo University of Information Sciences,

More information

Mechanical aspects, FEA validation and geometry optimization

Mechanical aspects, FEA validation and geometry optimization RF Fingers for the new ESRF-EBS EBS storage ring The ESRF-EBS storage ring features new vacuum chamber profiles with reduced aperture. RF fingers are a key component to ensure good vacuum conditions and

More information

Using the BHM binaural head microphone

Using the BHM binaural head microphone 11/17 Using the binaural head microphone Introduction 1 Recording with a binaural head microphone 2 Equalization of a recording 2 Individual equalization curves 5 Using the equalization curves 5 Post-processing

More information

FIRST WORKSHOP. Airbus A320 Main Landing Gear Door Ground Vibration Testing. Delft, September 10, 2015 Presenter: Pascal Lubrina (ONERA)

FIRST WORKSHOP. Airbus A320 Main Landing Gear Door Ground Vibration Testing. Delft, September 10, 2015 Presenter: Pascal Lubrina (ONERA) FIRST WORKSHOP Airbus A320 Main Landing Gear Door Ground Vibration Testing Delft, September 10, 2015 Presenter: Pascal Lubrina (ONERA) Airbus A320 Main Landing Gear Door Ground Vibration Testing Pascal

More information

THE EFFECT OF PERFORMANCE STAGES ON SUBWOOFER POLAR AND FREQUENCY RESPONSES

THE EFFECT OF PERFORMANCE STAGES ON SUBWOOFER POLAR AND FREQUENCY RESPONSES THE EFFECT OF PERFORMANCE STAGES ON SUBWOOFER POLAR AND FREQUENCY RESPONSES AJ Hill Department of Electronics, Computing & Mathematics, University of Derby, UK J Paul Department of Electronics, Computing

More information

Choosing an Oscilloscope

Choosing an Oscilloscope Choosing an Oscilloscope By Alan Lowne CEO Saelig Company (www.saelig.com) Post comments on this article at www.nutsvolts.com/ magazine/article/october2016_choosing-oscilloscopes. All sorts of questions

More information

Gyrophone: Recognizing Speech From Gyroscope Signals

Gyrophone: Recognizing Speech From Gyroscope Signals Gyrophone: Recognizing Speech From Gyroscope Signals Yan Michalevsky Dan Boneh Computer Science Department Stanford University Abstract We show that the MEMS gyroscopes found on modern smart phones are

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 7.9 THE FUTURE OF SOUND

More information

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing Application Note #63 Field Analyzers in EMC Radiated Immunity Testing By Jason Galluppi, Supervisor Systems Control Software In radiated immunity testing, it is common practice to utilize a radio frequency

More information

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1 Content 1. Company Profile... 3 2. Product Introduction... 3 3. Operation Instruction...

More information

Scanning A/D Converters, Waveform Digitizers, and Oscilloscopes

Scanning A/D Converters, Waveform Digitizers, and Oscilloscopes Scanning A/D Converters, Waveform Digitizers, and Oscilloscopes Scanning A/Ds, waveform digitizers and oscilloscopes all digitize analog signals. In all three instrument types, the purpose is to capture

More information

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders Scott Hewitt, President SICK STEGMANN, INC. Dayton, OH www.stegmann.com sales@stegmann.com 800-811-9110 The

More information

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing ECNDT 2006 - Th.1.1.4 Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing R.H. PAWELLETZ, E. EUFRASIO, Vallourec & Mannesmann do Brazil, Belo Horizonte,

More information

MachineryMate 800 operating guide Handheld vibration meter

MachineryMate 800 operating guide Handheld vibration meter MachineryMate 800 operating guide Handheld vibration meter Wilcoxon Sensing Technologies 20511 Seneca Meadows Parkway, Germantown MD 20876, USA Amphenol (Maryland), Inc d/b/a Wilcoxon Sensing Technologies

More information

Adaptive Resampling - Transforming From the Time to the Angle Domain

Adaptive Resampling - Transforming From the Time to the Angle Domain Adaptive Resampling - Transforming From the Time to the Angle Domain Jason R. Blough, Ph.D. Assistant Professor Mechanical Engineering-Engineering Mechanics Department Michigan Technological University

More information

4 MHz Lock-In Amplifier

4 MHz Lock-In Amplifier 4 MHz Lock-In Amplifier SR865A 4 MHz dual phase lock-in amplifier SR865A 4 MHz Lock-In Amplifier 1 mhz to 4 MHz frequency range Low-noise current and voltage inputs Touchscreen data display - large numeric

More information

Entwicklungen der Mikrosystemtechnik. in Chemnitz

Entwicklungen der Mikrosystemtechnik. in Chemnitz Entwicklungen der Mikrosystemtechnik Gliederung: in Chemnitz Fraunhofer Institut für f r Zuverlässigkeit und Mikrointegration IZM Institutsteil Multi Device Integration, Chemnitz, Thomas Gessner jan.mehner@che.izm.fhg.de

More information

9070 Smart Vibration Meter Instruction Manual

9070 Smart Vibration Meter Instruction Manual 9070 Smart Vibration Meter Instruction Manual Overall machine and bearing conditions: vibration values are displayed with color coded alarm levels for ISO values and Bearing Damage (BDU). Easy vibration

More information

NuQ152-WH # # connector plate carries Neutrik speakon* NL4 connectors for input and link connections to additional enclosures.

NuQ152-WH # # connector plate carries Neutrik speakon* NL4 connectors for input and link connections to additional enclosures. Product Information Document 2 way full range loudspeaker for portable PA and installation applications 5 Watts continuous, 2, Watts peak power Ideal for FOH, side fill and monitor applications Carbon

More information

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full. TENDER SPECIFICATIONS FOR THE SUPPLY, DELIVERY, INSTALLATION AND COMMISSIONING OF ONE UNIT OF VARIABLE PRESSURE ENVIRONMENTAL SCANNING ELECTRON MICROSCOPE (SEM) CUM ENERGY DISPERSIVE SPECTROSCOPY (EDS)

More information

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs By: Jeff Smoot, CUI Inc Rotary encoders provide critical information about the position of motor shafts and thus also their

More information

The Versatility in Vibration Measurement Datasheet

The Versatility in Vibration Measurement Datasheet OFV-5000 Vibrometer Controller The OFV-5000 Controller is the core of Polytec s latest state-of-the-art laser vibrometer systems. Its modular design allows the frequency, velocity and displacement capabilities

More information

Area-Efficient Decimation Filter with 50/60 Hz Power-Line Noise Suppression for ΔΣ A/D Converters

Area-Efficient Decimation Filter with 50/60 Hz Power-Line Noise Suppression for ΔΣ A/D Converters SICE Journal of Control, Measurement, and System Integration, Vol. 10, No. 3, pp. 165 169, May 2017 Special Issue on SICE Annual Conference 2016 Area-Efficient Decimation Filter with 50/60 Hz Power-Line

More information

INTRODUCTION. SLAC-PUB-8414 March 2000

INTRODUCTION. SLAC-PUB-8414 March 2000 SLAC-PUB-8414 March 2 Beam Diagnostics Based on Time-Domain Bunch-by-Bunch Data * D. Teytelman, J. Fox, H. Hindi, C. Limborg, I. Linscott, S. Prabhakar, J. Sebek, A. Young Stanford Linear Accelerator Center

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1995 Metric CSJ 0508-01-258 SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1.0 Description This Item shall govern for the furnishing and installation of color Single

More information

SPECIAL REPORT OF THE SUBCOMMITTEE ON POLARITY STANDARDS 1

SPECIAL REPORT OF THE SUBCOMMITTEE ON POLARITY STANDARDS 1 This document has been converted from the original publication: Thigpen, Ben B., Dalby, A. E. and Landrum, Ralph, 1975, Report on Subcommittee on Polarity Standards *: Geophysics, 40, no. 04, 694-699.

More information

Digital BPMs and Orbit Feedback Systems

Digital BPMs and Orbit Feedback Systems Digital BPMs and Orbit Feedback Systems, M. Böge, M. Dehler, B. Keil, P. Pollet, V. Schlott Outline stability requirements at SLS storage ring digital beam position monitors (DBPM) SLS global fast orbit

More information

onitoring Bearing Vibration with Seismic Transducers

onitoring Bearing Vibration with Seismic Transducers DEPARTMENTS onitoring Bearing Vibration M with Seismic Transducers Dr. Ryszard Nowicki Bently Nevada Asset Condition Monitoring Sales Application Engineer ryszard.nowicki@ge.com 7 8 O R B I T Vol.31 No.2

More information

An Introduction to Vibration Analysis Theory and Practice

An Introduction to Vibration Analysis Theory and Practice An Introduction to Vibration Analysis Theory and Practice An overview of Various Maintenance Methods Breakdown Preventive Predictive Reliability centered (Proactive) Vibration analysis What is machine

More information

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow ...Simple Effective Inexpensive to operate Economical The Saudi Factory for Air Conditioning Units No air cooled condenser needed No chiller or cooling tower needed No major control center No refrigerant

More information

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation Matthias Liepe Assistant Professor of Physics Cornell University Experience with the Cornell ERL Injector SRF

More information

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition

More information

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1993 Specifications CSJ 0027-12-086, etc. SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of color

More information

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance Table of Contents Introduction................................1 Axial pull test and horizontal shear test............2

More information

Detecting and Analyzing System for the Vibration Comfort of Car Seats Based on LabVIEW

Detecting and Analyzing System for the Vibration Comfort of Car Seats Based on LabVIEW Detecting and Analyzing System for the Vibration Comfort of Car Seats Based on LabVIEW Ying Qiu Key Laboratory of Conveyance and Equipment, Ministry of Education School of Mechanical and Electronical Engineering,

More information

Building Video and Audio Test Systems. NI Technical Symposium 2008

Building Video and Audio Test Systems. NI Technical Symposium 2008 Building Video and Audio Test Systems NI Technical Symposium 2008 2 Multimedia Device Testing Challenges Integrating a wide range of measurement types Reducing test time while the number of features increases

More information

RoomMatch RM and RM TECHNICAL DATA SHEET. asymmetrical array modules. Key Features. Product Overview. Technical Specifications

RoomMatch RM and RM TECHNICAL DATA SHEET. asymmetrical array modules. Key Features. Product Overview. Technical Specifications RoomMatch RM281 and RM281 Key Features All the benefits of the original 2 RoomMatch array module loudspeakers - Concert-quality sound quality for live music and outstanding spoken-word clarity with industry-leading

More information

A New Method for Processing Impact Excited Continuous-Scan Laser. Doppler Vibrometer Measurements

A New Method for Processing Impact Excited Continuous-Scan Laser. Doppler Vibrometer Measurements A New Method for Processing Impact Excited Continuous-Scan Laser Doppler Vibrometer Measurements Matthew S. Allen 1 and Michael W. Sracic Department of Engineering Physics University of Wisconsin-Madison

More information

Evaluation of a Vibration Text Fixture

Evaluation of a Vibration Text Fixture Evaluation of a Vibration Text Fixture Everaldo de Barros and Carlos d Andrade Souto Institute of Aeronautics and Space, Praça Eduardo Gomes, 50, 12228-904 São José dos Campos, SP, Brazil. (Received 9

More information

Brabender Twin Screw Extruders. for Laboratory and Pilot Plant Applications. where quality is measured.

Brabender Twin Screw Extruders. for Laboratory and Pilot Plant Applications. where quality is measured. Brabender Twin Screw Extruders for Laboratory and Pilot Plant Applications where quality is measured. Twin Screw Extruders Principle - application area The basic steps of compounding can perfectly be realized

More information

CAEN Tools for Discovery

CAEN Tools for Discovery Viareggio March 28, 2011 Introduction: what is the SiPM? The Silicon PhotoMultiplier (SiPM) consists of a high density (up to ~10 3 /mm 2 ) matrix of diodes connected in parallel on a common Si substrate.

More information

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS FOCUS ON FINE SOLUTIONS THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS Welding lasers from ROFIN ROFIN s laser sources for welding satisfy all criteria for the optimized laser

More information

UB22z Specifications. 2-WAY COMPACT FULL-RANGE See NOTES TABULAR DATA for details CONFIGURATION Subsystem DESCRIPTION

UB22z Specifications. 2-WAY COMPACT FULL-RANGE See NOTES TABULAR DATA for details CONFIGURATION Subsystem DESCRIPTION DESCRIPTION Ultra-compact 2-way system Wide projection pattern LF on angled baffles to maintain a wide upper/midrange beamwidth High output, high definition sound DESCRIPTION The UB22z is engineered for

More information

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera PRELIMINARY POWER DETECTORS ENERGY DETECTORS MONITORS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS CMOS Beam Profiling Camera AVAILABLE MODEL Beamage 3.0 (⅔ in CMOS

More information

An Ultra-low noise MEMS accelerometer for Seismology

An Ultra-low noise MEMS accelerometer for Seismology QuietSeis TM An Ultra-low noise MEMS accelerometer for Seismology aurelien.fougerat@sercel.com laurent.guerineau@sercel.com April 10 th, 2018 SERCEL Introduction French company founded in 1956, subsidiary

More information

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16] UNIT-3 Part A 1. What is CFAR loss? [ N/D-16] Constant false alarm rate (CFAR) is a property of threshold or gain control devices that maintain an approximately constant rate of false target detections

More information

PRAGUE TPZ122/64. # Designed and engineered in the U.K.

PRAGUE TPZ122/64. # Designed and engineered in the U.K. Arrayable 2 way full range loudspeaker for installation applications Rotatable waveguide with 6 H x 4 V dispersion 6 Watts continuous, 2,4 Watts peak power Carbon fibre loaded 12" low frequency driver

More information

Test of ScannerMAX Saturn 1 with 600Hz Sine-wave input, having an optical scan angle of 40 optical degrees peak to peak.

Test of ScannerMAX Saturn 1 with 600Hz Sine-wave input, having an optical scan angle of 40 optical degrees peak to peak. Test of ScannerMAX Saturn 1 with 600Hz Sine-wave input, having an optical scan angle of 40 optical degrees peak to peak. What follows are scope screen shots of a test of ScannerMAX Saturn 1B with our standard

More information

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

NDT Supply.com 7952 Nieman Road Lenexa, KS USA ETher ETherCheck Combined Eddy Current & Bond Testing Flaw Detector The ETherCheck is a combined Eddy Current and Bond Testing Flaw Detector which comes with a rich range of features offered by a best

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 5.3 ACTIVE NOISE CONTROL

More information

Open Research Online The Open University s repository of research publications and other research outputs

Open Research Online The Open University s repository of research publications and other research outputs Open Research Online The Open University s repository of research publications and other research outputs The effect of wall material on the structural vibrations excited when lip-reed instruments are

More information

Renishaw Ballbar Test - Plot Interpretation - Mills

Renishaw Ballbar Test - Plot Interpretation - Mills Haas Technical Documentation Renishaw Ballbar Test - Plot Interpretation - Mills Scan code to get the latest version of this document Translation Available This document has sample ballbar plots from machines

More information

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera Bingxin Yang, Alex H. Lumpkin, Katherine Harkay, Louis Emery, Michael Borland, and Frank Lenkszus Advanced

More information

What is the minimum sound pressure level iphone or ipad can measure? What is the maximum sound pressure level iphone or ipad can measure?

What is the minimum sound pressure level iphone or ipad can measure? What is the maximum sound pressure level iphone or ipad can measure? Technical Note 1701 i437l- Frequent Asked Questions Question 1 : What are the advantages of MicW i437l? Answer 1 : The i437l is a digital microphone connected to iphone Lightning connector. It has flat

More information

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes: PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties Due Thursday, 2 Nov 2017 For this lab, you will explore the properties of the working HeNe laser. 1. Observation of higher-order modes: Realign

More information

VBOX3i Dual Antenna. Measures Slip and Pitch/Roll (RLVB3iSL) Features

VBOX3i Dual Antenna. Measures Slip and Pitch/Roll (RLVB3iSL) Features VBOX3i dual antenna (VB3iSL) is Racelogic s most powerful GPS data logging system. By utilising two GPS engines configured in a Fixed Baseline RTK setup, the VB3iSL combines high level accuracy and test

More information

A COMPUTERIZED SYSTEM FOR THE ADVANCED INSPECTION OF REACTOR VESSEL STUDS AND NUTS BY COMBINED MULTI-FREQUENCY EDDY CURRENT AND ULTRASONIC TECHNIQUE

A COMPUTERIZED SYSTEM FOR THE ADVANCED INSPECTION OF REACTOR VESSEL STUDS AND NUTS BY COMBINED MULTI-FREQUENCY EDDY CURRENT AND ULTRASONIC TECHNIQUE More Info at Open Access Database www.ndt.net/?id=18566 A COMPUTERIZED SYSTEM FOR THE ADVANCED INSPECTION OF REACTOR VESSEL STUDS AND NUTS BY COMBINED MULTI-FREQUENCY EDDY CURRENT AND ULTRASONIC TECHNIQUE

More information

E X P E R I M E N T 1

E X P E R I M E N T 1 E X P E R I M E N T 1 Getting to Know Data Studio Produced by the Physics Staff at Collin College Copyright Collin College Physics Department. All Rights Reserved. University Physics, Exp 1: Getting to

More information

Application Note AN-LD09 Rev. B Troubleshooting Low Noise Systems. April, 2015 Page 1 NOISE MEASUREMENT SYSTEM BASELINES INTRODUCTION

Application Note AN-LD09 Rev. B Troubleshooting Low Noise Systems. April, 2015 Page 1 NOISE MEASUREMENT SYSTEM BASELINES INTRODUCTION Troubleshooting Low Noise Systems April, 2015 Page 1 INTRODUCTION The exceedingly low level of electronic noise produced by the QCL family of drivers makes narrower linewidths and stable center wavelengths

More information

Sound and Vibration Data Acquisition

Sound and Vibration Data Acquisition NI PXI-449x, NI PXIe-449x NEW! 16 simultaneous analog inputs 24-bit resolution 204.8 ks/s maximum sampling rate 114 db dynamic range +10, +20, and +30 db gains ±0.316, 1, 3.16, and 10 V input ranges Antialiasing

More information

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual Field Test 2 Installation and operation manual OPDAQ 17.08.25 Installation and operation manual January 2016 How to get copies of OpDAQ technical publications: 53, St-Germain Ouest Rimouski, Québec Canada

More information

PEP-I1 RF Feedback System Simulation

PEP-I1 RF Feedback System Simulation SLAC-PUB-10378 PEP-I1 RF Feedback System Simulation Richard Tighe SLAC A model containing the fundamental impedance of the PEP- = I1 cavity along with the longitudinal beam dynamics and feedback system

More information

COMMISSIONING OF THE ALBA FAST ORBIT FEEDBACK SYSTEM

COMMISSIONING OF THE ALBA FAST ORBIT FEEDBACK SYSTEM COMMISSIONING OF THE ALBA FAST ORBIT FEEDBACK SYSTEM A. Olmos, J. Moldes, R. Petrocelli, Z. Martí, D. Yepez, S. Blanch, X. Serra, G. Cuni, S. Rubio, ALBA-CELLS, Barcelona, Spain Abstract The ALBA Fast

More information

PSM-003. Micro Polarization Controller/Scrambler. User Guide

PSM-003. Micro Polarization Controller/Scrambler. User Guide PSM-003 Micro Polarization Controller/Scrambler User Guide Version: 1.0 Date: August 23, 2012 General Photonics, Incorporated is located in Chino California. For more information visit the company's website

More information

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR Proceedings of FEL213, New York, NY, USA STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR F. Loehl, J. Alex, H. Blumer, M. Bopp, H. Braun, A. Citterio, U. Ellenberger, H. Fitze, H. Joehri, T. Kleeb, L.

More information

LIVERPOOL TLX43. Custom-Engineered Drivers

LIVERPOOL TLX43. Custom-Engineered Drivers Compact 2 way line array element for portable and fixed installation application 15 Watts continuous, 6 Watts peak power Ideal for FOH, center cluster, offstage fill, stereo in-fill or distributed fill

More information

Rendering Spatio-Temporal Dynamic of Deformable Mirrors

Rendering Spatio-Temporal Dynamic of Deformable Mirrors Rendering Spatio-Temporal Dynamic of Deformable Mirrors V. Markov, A. Khizhnyak, J. Kilpatrick, J. Weldon Advanced Systems & Technologies, Inc. G. Osborne Naval Air Warfare Center Weapon Division Irvine,

More information

CATHODE-RAY OSCILLOSCOPE (CRO)

CATHODE-RAY OSCILLOSCOPE (CRO) CATHODE-RAY OSCILLOSCOPE (CRO) I N T R O D U C T I O N : The cathode-ray oscilloscope (CRO) is a multipurpose display instrument used for the observation, measurement, and analysis of waveforms by plotting

More information

Acoustic Camera 2018

Acoustic Camera 2018 Acoustic Camera 2018 Product presentation A new modular design concept for acoustic arrays Acoustic beamforming arrays, commonly known as acoustic cameras, enable the user to visualise different sound

More information