Mosaic. Mosaic Real Time Parallel Illumination of Multiple Regions. Features and Benefits. DMD Technology. Specifications Summary

Size: px
Start display at page:

Download "Mosaic. Mosaic Real Time Parallel Illumination of Multiple Regions. Features and Benefits. DMD Technology. Specifications Summary"

Transcription

1 Active Illumination Features and Benefits Unlimited flexibility in shape, size and complexity of illumination mask Simultaneous illumination of multiple regions of interest Precise illumination of areas of interest that protects target specimen and fluorophore Zero delta acquisition time for true digital excitation/illumination Longest lifetime and lowest maintenance with rugged semiconductor device DMD Technology The core of Mosaic is the Digital Micromirror Device (DMD), a high speed and highly efficient semiconductor-based light switch array of hundreds of thousands hinge-mounted, addressable, tiltable, microscopic mirrors. When a DMD chip is coordinated with a digital video or graphic signal, a light source, and beam delivery optics, its mirrors reflect a digital image of the illumination mask onto the sample. Mosaic Real Time Parallel Illumination of Multiple Regions Mosaic is a patented instrument platform built around MEMS Digital Mirror Devices (DMD). Mosaic exploits DMD in a proprietary programmable platform, integrated with scientific light sources including lasers, LEDs and arc lamps, and operates from 360 to 800 nm. It is offered with a range of high performance microscope adapter optics and can be integrated with CLSM, spinning disk and wide field imaging modalities. High speed frame switching (60 Hz) makes Mosaic suitable for many dynamic applications including bleaching, uncaging, photo-switching, optogenetics and constrained illumination. Variable intensity distributions can be achieved by rapid gating of mirror patterns. Specifications Summary Transmission Extinction ratio > 1000:1 Minimum resolvable spot Optical pixel rise / fall time < 1 µs Minimum optical pulse width Maximum frame repetition rate 360 nm to 800 nm Diffraction limited with 60x or 100x objective 75 µs external trigger 100 µs internal trigger 600 frames / sec Certification CDRH IIIb (if fitted with a laser source) Page 1 of 9

2 Hardware Specifications Optical Model Mosaic Mosaic Transmission Intensity stability 360 nm to 800 nm Absolute Extinction ratio > 1000:1 Minimum resolvable spot Fields of view Illumination port clear aperture Diffraction limited with 100x objective 7206 = 5.4 x 4.1 mm 7201 = 15.2 x 11.3 mm Ø 34 mm For flat field illumination port options, please see table at bottom of this section Illumination Source Options DMD illumination ports 1 or 2 on left hand side* 1 or 2 on left hand side, 1 or 2 on right hand side* Incoherent sources High pressure mercury lamp (100 W - 300W) DG4 Andor AMH-200 Other light sources on request CW laser 405 nm diode 488 nm Argon 514 nm Argon Other on request * 7201 allows only 1 port, 7206 allows 2 ports Additional illumination source options available on request Illumination Port Options Dichroic beamsplitter Single pass, specify wavelength Multi-pass, specify wavelength Beamsplitter 360 nm to 700 nm, R = 100, 70, 50 or 30% Excitation filter * Laser safety filter, interlocks 480 nm / 20 nm (GFP), 470 nm / 40 nm (FITC) - 38 mm Other filters on request - 25 mm with adapter Laser specific Optional * Additional excitation filter options available on request Flat field EPI illumination ports Adapter Leica DMI series Nikon TE2000 Nikon Ti series Nikon Universal Olympus IX series Part Number MM-7310-DMI-FFEP-X* MM-7310-TE2K-FFEP-X* MM-7310-TI-FFEP-X* MM-7310-NFS-FFEP-X* MM-7310-IX70-FFEP-X* Adapter Zeiss Axiovert 200 Zeiss Axio Examiner D1 Zeiss Axio Imager M1 Zeiss Axio Observer C-mount video port Part Number MM-7310-ZSAV-FFEP-X* MM-7310-D1-FFEP-X* MM-7310-IMG-FFEP-X* MM-7310-OBS-FFEP-X* On request *For 7201, X = 1 *For 7206, X = 2 INTEROPERABILITY Compatible with microscopes platforms - point & slit scan confocal, spinning disk confocal & widefield. Custom OEM systems available for High Content Screening and other fluorescence based imaging instrumentation. Compatible with control and acquisition software from market leading microscope manufacturers including Carl Zeiss, Leica and Olympus. Wavelength modularity - add lasers and filters cost effectively. Page 2 of 9

3 Software Specifications The Mosaic system includes software that controls calibration and enables the user to graphically or numerically define and edit the shape and characteristics of the illumination at the target. Release MicroPoint Mosaic Version 1.1 Drivers Calibration Operating systems File Functions Drawing Editor Shapes Drawn Shape Characteristics Controls Options PLX 9054 API version 4.1 for Mosaic.exe UI PLX 9054 API version 6 for SDK Scale & Offset corrections for X & Y 8 user-defined descriptions Windows 2000, XP Import (*.dxf, *.bmp, *.msk); Save *.msk Line, Paintbrush, Rectangle, Oval, Freehand polyshape Line width, paintbrush size, Alpha blended color and opacity of defined regions, Color palette Click and drag shapes and edges, cut, copy, paste, delete shape, Group, ungroup shapes Engage mask pattern, Go dark (global), Stop, Snapshot video Continuous update from drawing editor, Configure video subsystem, Exposure time & trigger selection Video mode & time selection, On/Off, Adjust laser outline highlight The angular alignment of either the CW laser or lamp illumination is factory set. The spatial alignment is controlled via the software calibration routine. The focus in the z direction is fixed at installation or OEM integration. Beam shaping is then controlled with the spatial light modulating DMD. Define region of interest and excitation energy at the target in image acquisition software Simultaneously excite and acquire image with zero delta time Software Compatibility - Life Science Applications Mosaic systems are compatible with a wide range of life science imaging software as indicated in the table below. Andor iq Version 2.0 MicroPoint Laser Galvo Version 1.0 MDC MetaMorph Ver 7.1 and above (32-bit) MDC MetaMorph Ver 7.74 and above (64-bit) Nikon NIS Elements 3.0 SP4 Build 505 Software Development Kits (SDK) Live cell multi-dimensional imaging with flexible control of MicroPoint Image-based targeting, control & calibration Fully integrated MicroPoint support with powerful imaging capabilities Fully integrated MicroPoint support with powerful imaging capabilities Multi-dimensional imaging with simple/fast control of MicroPoint SDKs are available for OEM to develop software to control integrated MicroPoint systems Page 3 of 9

4 Components The main components of Mosaic are shown below: Beamsplitter/ dichroic plugs Flange for EPI source DMD array Electronic interface Laser fiber input Laser zoom collimator Flange for optional second light source Page 4 of 9

5 Ordering your Mosaic system Prior to commencing the order process, please advise your customer representative of your application requirements. Please also refer to the flow charts on the next 2 pages. Step 1. Confirm your Microscope make and model Leica, Nikon, Olympus, Zeiss Step 2. The following field of illumination options are available: 7201 = 15.2 x 11.3 mm and 7206 = 5.4 x 4.1 mm Step 1. In order to allow us to select the correct model for your requirements please advise your customer representative of the make, model (and any accessories fitted) of the microscope being used. Step 2. Please select the field of illumination required. Step 3a. Select the primary left sided DMD light source. For the 7206 option only, a secondary left side light source can also be selected at this point. Step 3b. For Mosaic systems only a primary right sided light source can also be selected. For the 7206 option only, a secondary right side light source can also be selected at this point. Step 4. Select the type of EPI light source require. Step 5. Step 3a. The following DMD light sources / filter sets for the left side port of Mosaic are available: Diode laser, XLED1, Other laser, Andor AMH, DG4, Hg The following left sided excitation filters are available: GFP filter in holder (480/20), FITC (470/40),Blank filter holder, Others on request Secondary left sided DMD source, select one or more of the following beamsplitters: 30 EPI, 50 EPI,70 EPI, 100% EPI Plug, 0% EPI (Blank) Plug. A range of dichroic mirrors is available on request. Step 3b. For Mosaic systems only, additional DMD light sources / filter sets for the right side port: Diode laser, XLED1, Other laser, Andor AMH, DG4, Hg The following right sided excitation filters are available: GFP filter in holder (480/20), FITC (470/40),Blank filter holder, Others on request Secondary right sided DMD source, select one or more of the following beamsplitters: 30 EPI, 50 EPI, 70 EPI, 100% EPI Plug, 0% EPI (Blank) Plug. A range of dichroic mirrors is available on request. Step 4. The following EPI light sources are available: Andor AMH, XLED1, DG4, Microscope specific Hg lamp, MicroPoint, other Step 5. Optional EPI Excitation filters are also available: GFP filter in holder (480/20), FITC (470/40). Others on request Step 6. The following EPI-Mosaic beamsplitters are available: 30 EPI, 50 EPI, 70 EPI, 100% EPI plug, 0% EPI (Blank) Plug Choose one or more optional EPI excitation filters. Step 6. Choose one or more EPI / Mosaic beamsplitters. Page 5 of 9

6 Configuring Mosaic The Mosaic can be tailored to suit your needs, there are a number of options including mosaic illumination sources, EPI illumination sources, Active mirror array magnification and filtering. Microscope Olympus Nikon Zeiss Leica Microscope Options Mosaic Illumination Input with & BNC Cable Laser Delivery / safety filters Three Channel TTL synchronization modules with delay and duration inputs/outputs Field of Illumination x 11.3mm 5.4 x 4.1mm Mosaic Input Light Source Diode laser XLED1 AMH DG4 Hg Other Note: If laser chosen, then laser kit (containing fluorescent target, fiber coupler, homogenizer, fiber collimator & interlock) is required Input Excitation Filter Large GRP filter in holder (480 x 40nm) Large blank filter holder Secondary Light Source Beamsplitters (Choose one or more) 30 EPI:70 Laser Beamsplitter Plug 50 EPI:50 Laser Beamsplitter Plug 70 EPI:30 Laser Beamsplitter plug 100% EPI Plug 0% EPI (Blank) Plug EPI Light Source AMH DG4 XLED1 Hg MicroPoint Other 5 Optional EPI Excitation Filters (Choose one or more if required) FITC exciter filter GFP exciter filter Rhodamine exciter filter Blank filter holder EPI/ Mosaic Beamsplitter 30 EPI:70 Laser Beamsplitter Plug 100% EPI Plug 50 EPI:50 Laser Beamsplitter Plug 0% EPI (Blank) Plug 70 EPI:30 Laser Beamsplitter Plug Multiplex with MicroPoint For applications requiring both ablation and zero delta time fluorescence excitation of multiple regions with complex geometries, the Mosaic s EPI Illumination port can be fitted with a Micropoint system and filtering. Page 6 of 9

7 Configuring Mosaic (Complementary Multicolour Illumination) Some photosensitive proteins can be activated with one wavelength of light and deactivated or silenced with another. This property is exploited in the Mosaic e.g. to sharpen control over protein localization. A second light source is coupled into the DMD at a complementary angle to the primary. In this configuration pixels NOT selected for activation define an inverse mask which can be illuminated to silence molecules outside of the activation region(s) or those diffusing away. Microscope Olympus Nikon Zeiss Leica Microscope Options Mosaic Illumination Input with & BNC Cable Laser Delivery / safety filters Three Channel TTL synchronization modules with delay and duration inputs/outputs Field of Illumination x 4.1mm Primary Left Sided Light Source Diode laser XLED1 AMH DG4 Hg Other Note: If laser chosen, then laser kit (containing fluorescent target, fiber coupler, homogenizer, fiber collimator & interlock) is required Left Side Excitation Filter Large GRP filter in holder (480 x 40nm) Large blank filter holder Secondary Left Side Light Source Beamsplitters (Choose one or more) 30 EPI:70 Laser Beamsplitter Plug 50 EPI:50 Laser Beamsplitter Plug 70 EPI:30 Laser Beamsplitter plug 100% EPI Plug 0% EPI (Blank) Plug Primary Right Sided Light Source Diode laser XLED1 AMH DG4 Hg Other Note: If laser chosen, then laser kit (containing fluorescent target, fiber coupler, homogenizer, fiber collimator & interlock) is required Right Side Excitation Filter Large GRP filter in holder (480 x 40nm) Large blank filter holder EPI Light Source AMH DG4 XLED1 Hg MicroPoint Other Secondary Right Side Light Source Beamsplitters (Choose one or more) 30 EPI:70 Laser Beamsplitter Plug 50 EPI:50 Laser Beamsplitter Plug 70 EPI:30 Laser Beamsplitter plug 100% EPI Plug 0% EPI (Blank) Plug EPI/ Mosaic Beamsplitter 30 EPI:70 Laser Beamsplitter Plug 100% EPI Plug 50 EPI:50 Laser Beamsplitter Plug 0% EPI (Blank) Plug 70 EPI:30 Laser Beamsplitter Plug 5 Optional EPI Excitation Filters (Choose one or more if required) FITC exciter filter GFP exciter filter Rhodamine exciter filter Blank filter holder Page 7 of 9

8 Product Drawings Dimensions in mm [inches] Fields of Illumination (FoI) [3.8] 80 [3.1] Model FOV (Lamp house) Diagonal, mm [3.0] 0 FOV (Lamp house) XY, mm 15.2 x x 4.1 FOV 0.4 mm fiber ZC* x2 (mm)** 13.7 x x [3.8] FOV 0.4 mm fiber ZC x1 (mm)*** FOV 0.2 mm fiber ZC x2 (mm)** FOV 0.2 mm fiber ZC x1 (mm)** [5.8] [4] Fiber Bend Radius Laser Fiber Collimator Mosaic Lamphouse Adapter 175 [6.88] (Lamphouse Attachment Plane) DMD effective pixel size (µm) *ZC = Zoom Collimator X2 = max; X1 = min ** Intersection of circle and DMD rectangle *** Circular field of illumination Moves 38.1[1.50] Removeable Beamsplitter 57 [2.2] Ø Cylinder Moves 38.1[1.50] 76.2 [3.0] 0 See Table Weights: Mosaic Body = 3.5 kg [7.5 lb] 160 [6.3] Mosaic Body = 4.5 kg [9.8 lb] [3.1] Body Dimensions Model Part Number Length 7201 MEC mm [14.53] 76.2 [3.0] MEC mm [13.1] (Laser Input Attachment) 146 [5.8] [4] Fiber Bend Radius Mosaic Lamphouse Adapter 160 [6.3] 229 [9.0] 240 [9.375] (Lamphouse Attachment Plane) Laser Fiber Collimator Removeable Beamsplitter 57 [2.2] Ø Cylinder Moves 38.1[1.50] Moves 38.1[1.50] 76.2 [3.0] [13.1] Page 8 of 9

9 Order Today Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our regional sales offices, please see: /contact Our regional headquarters are: Europe Belfast, Northern Ireland Japan Tokyo Phone +44 (28) Phone +81 (3) Fax +44 (28) Fax +81 (3) North America China Connecticut, USA Beijing Phone +1 (860) Phone +86 (10) Fax +1 (860) Fax +86 (10) Items shipped with your Mosaic: 1x DMD Head assembly, Mosaic II 1x PLX and daughter board pair, programmed 1x 10 SCSI-3 Ultra LVD/SE MD698 cable 1x TPES15-T050PP-7 Mosaic custom power supply 1x 3m mains cable for TPES15-T050PP-7 1x First surface mirror 10x Green Post-It notes 1x Allen key (0.05 ) 1x T-handle (3/32) 1x LED Maglite, with 2 xaa batteries 1x Maglite clamp 1x Mosaic post holder 1x Mosaic foot 1x NT stainless steel post (1/4-20 UNC) 1x NT stainless steel post (1/4-20 UNC) 1x Zeiss male flange 1x BNC finger assembly 1x User guide NOTE: Laser radiation is only present in Mosaic systems fitted with a laser. Some Mosaic systems use non laser-based light sources. Minimum Computer Requirements: The imaging computer must have two adjacent PCI slots (with exceptions) and a bay for BNC Trigger connectors. Application software for the Mosaic Digital Diaphragm System is typically integrated into the imaging software provided for the microscope. Operating & Storage Conditions Operating Temperature: 0 C to 30 C ambient Relative Humidity: < 70% (non-condensing) Storage Temperature -25 C to 50 C Power Requirements VAC, Hz, 1.0 A Windows is a registered trademark of Microsoft Corporation. MMosaicSS 0213 R1 Page 9 of 9

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination Advanced LED Illumination for Fluorescence Microscopy X-Cite XLED1 Resetting the standard for LED illumination Optimized excitation with high power LED illumination at the sample plane Instant switching

More information

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company A TyRex Technology Family Company CEL5500 LIGHT ENGINE PRODUCT GUIDE World Leader in DLP Light Exploration Digital Light Innovations (512) 617-4700 dlinnovations.com CEL5500 Light Engine The CEL5500 Compact

More information

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body Beta TX Datasheet Beta-TX The Beta-TX is a complete self contained laser diode system which can operate in both CW and modulation modes. The Beta- TX features high speed modulation with a bandwidth of

More information

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately The from Princeton Instruments is the ultimate scientific, intensified CCD camera (ICCD) system, featuring a 1k x 1k interline CCD fiberoptically coupled to Gen III filmless intensifiers. These intensifiers

More information

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS FOCUS ON FINE SOLUTIONS THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS Welding lasers from ROFIN ROFIN s laser sources for welding satisfy all criteria for the optimized laser

More information

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter Fully compliant to LXI Class C specification General Information Up to 8 power meter channels in a

More information

Industrial Diode Laser (IDL) System IDL Series

Industrial Diode Laser (IDL) System IDL Series COMMERCIAL LASERS Industrial Diode Laser (IDL) System IDL Series Key Features Round, top-hat beam profile for uniform power distribution Warranted for full rated power in either pulsed or continuous wave

More information

Light Delivery Systems for Optogenetics

Light Delivery Systems for Optogenetics Product Catalog and Selection Guide August 2013 Edition Simply Brighter Solutions for Optogenetics WWW.MIGHTEX.COM WWW.MIGHTEXSYSTEMS.COM Mightex Systems 2013 All Rights Reserved. Introduction Optogenetics

More information

STAR-07 RGB MULTI-COLOR INDUSTRIAL PATTERN PROJECTION

STAR-07 RGB MULTI-COLOR INDUSTRIAL PATTERN PROJECTION STAR-07 RGB MULTI-COLOR INDUSTRIAL PATTERN PROJECTION STAR-07 RGB is a high performance DLP projector based upon the Texas Instruments micromirror technology and designed to serve in demanding industrial

More information

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications March 2006 Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical

More information

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging Compatible Windows Software GLOBAL LAB Image/2 DT Vision Foundry DT3162 Variable-Scan Monochrome Frame Grabber for the PCI Bus Key Features High-speed acquisition up to 40 MHz pixel acquire rate allows

More information

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device Dynamic IR Scene Projector Based Upon the Digital Micromirror Device D. Brett Beasley, Matt Bender, Jay Crosby, Tim Messer, and Daniel A. Saylor Optical Sciences Corporation www.opticalsciences.com P.O.

More information

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope Indiana Center for Biological Microscopy Zeiss LSM-510 510-UV Confocal Microscope Microscope and the Attached Accessories Transmission Detector Halogen Lamp House Condenser Eyepiece Stage Scanning and

More information

CBF500 High resolution Streak camera

CBF500 High resolution Streak camera High resolution Streak camera Features 400 900 nm spectral sensitivity 5 ps impulse response 10 ps trigger jitter Trigger external or command 5 to 50 ns analysis duration 1024 x 1024, 12-bit readout camera

More information

HP 70950B OPTICAL SPECTRUM ANALYZER

HP 70950B OPTICAL SPECTRUM ANALYZER HP 71450B, 71451B, and 71452B Optical Spectrum Analyzers Technical Specifications Spectral Measurements from 600 to 1700 nm HP 70950B OPTICAL SPECTRUM ANALYZER OPTICAL INPUT The HP 71450B, 71451B, and

More information

DT3130 Series for Machine Vision

DT3130 Series for Machine Vision Compatible Windows Software DT Vision Foundry GLOBAL LAB /2 DT3130 Series for Machine Vision Simultaneous Frame Grabber Boards for the Key Features Contains the functionality of up to three frame grabbers

More information

In-process inspection: Inspector technology and concept

In-process inspection: Inspector technology and concept Inspector In-process inspection: Inspector technology and concept Need to inspect a part during production or the final result? The Inspector system provides a quick and efficient method to interface a

More information

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life Leica TCS CARS Live Molecular Profiling Technical Documentation Living up to Life Microscopes Inverted Leica DMI6000 CS Microscope anti-vibration table Specification Vibration insulation Passive Z-drive

More information

IMPAC Infrared Thermometers

IMPAC Infrared Thermometers IMPAC Infrared Thermometers focusable optics for non-contact temperature measurements on metals, ceramics, graphite etc. between 300 and 3300 C IS 140 IGA 140 IS 140-PB IGA 140-PB Short response times

More information

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator 20 Channel Digital Delay Generator Features of the 745T-20C: 20 Independent delay channels - 100 ps resolution - 25 ps rms jitter - 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every

More information

GFT Channel Digital Delay Generator

GFT Channel Digital Delay Generator Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Fours Triggers Three are repetitive from three

More information

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules DT9834 Series High-Performance Multifunction USB Data Acquisition Modules DT9834 Series High Performance, Multifunction USB DAQ Key Features: Simultaneous subsystem operation on up to 32 analog input channels,

More information

CONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes

CONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes CONFOCAL MICROSCOPE Instrument Details: Make: Zeiss Modal: LSM 700 Specifications: Microscopes Stands: Upright: Axio Imager.Z1m, M1m and Axio Scope mot for LSM Inverted: Axio Observer.Z1m SP (side port)

More information

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters Data Sheet Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical power of laser light

More information

LD OEM/LD PDS/LD PeCo

LD OEM/LD PDS/LD PeCo LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class

More information

STAR-07. Industrial Pattern Projection. System Architecture. System Control

STAR-07. Industrial Pattern Projection. System Architecture. System Control STAR-07 Industrial Pattern Projection STAR-07 is a high performance DLP projector based upon the Texas Instruments micromirror technology and designed to serve in demanding industrial applications. Widely

More information

USA Price List. January or 8-channel LIBSCAN system (100 mj, 1064 nm laser) Alternative LIBSCAN configurations

USA Price List. January or 8-channel LIBSCAN system (100 mj, 1064 nm laser) Alternative LIBSCAN configurations USA Price List January 2012 PRODUCT CODE LIBSCAN 100 LIBSCAN DESCRIPTION 6 or 8-channel LIBSCAN system (100 mj, 1064 nm laser) Includes LIBSCAN head, laser, spectrometer console, interconnecting umbilical

More information

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical power of laser

More information

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET IMPAC Infrared Temperature Sensors focusable optics for non-contact temperature measurements on metals, ceramics, graphite etc. between 220 and 3500 C IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA

More information

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS LVM-4000 LASER VALVE MOTION measurement system OH-1000 LASER VIBROMETER HEAD LASER-BASED TECHNOLOGY SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS ENGINE HEAD VIBRATION

More information

SPATIAL LIGHT MODULATORS

SPATIAL LIGHT MODULATORS SPATIAL LIGHT MODULATORS Reflective XY Series Phase and Amplitude 512x512 A spatial light modulator (SLM) is an electrically programmable device that modulates light according to a fixed spatial (pixel)

More information

OPTICAL POWER METER WITH SMART DETECTOR HEAD

OPTICAL POWER METER WITH SMART DETECTOR HEAD OPTICAL POWER METER WITH SMART DETECTOR HEAD Features Fast response (over 1000 readouts/s) Wavelengths: 440 to 900 nm for visible (VIS) and 800 to 1700 nm for infrared (IR) NIST traceable Built-in attenuator

More information

KVANT. Spectrum 1,6W RGB laser system. Product datasheet

KVANT. Spectrum 1,6W RGB laser system. Product datasheet KVANT Spectrum 1,6W RGB laser system Product datasheet SPECTRUM series professional full colour laser system 1. DESCRIPTION Kvant Spectrum is professional laser system with wide range of use, mainly for

More information

InGaAs multichannel detector head

InGaAs multichannel detector head Near infrared line camera (Line rate: 31.25 khz) The is a multichannel detector head suitable for applications where high-speed response is required, such as SD- OCT (spectral domain-optical coherence

More information

SMT Encoder for High Performance, High Volume Designs Small Size High Resolution Low Cost ChipEncoder Reflective Surface Mount Encoder Features

SMT Encoder for High Performance, High Volume Designs Small Size High Resolution Low Cost ChipEncoder Reflective Surface Mount Encoder Features SMT Encoder for High Performance, High Volume Designs Small Size 7.0mm (W) x 11.0mm (L) x 3.1mm (H) High Resolution Linear: 10μm or 1μm per quadrature count Rotary: 3,300 to 327,000 quadrature counts per

More information

Fiber-coupled light sources

Fiber-coupled light sources Optogenetics catalog 7.4 - Fiber-coupled light sources 9 Fiber-coupled light sources The fiber optic circuits are driven by light and hence the need to couple the light sources into the optical fiber.

More information

Create an Industrial 3D Machine Vision System using DLP Technology

Create an Industrial 3D Machine Vision System using DLP Technology Create an Industrial 3D Machine Vision System using DLP Technology -AM572x Processor based DLP Structured Light Terry Yuan Business Development Manager 1 1987 TI DLP Products: A History of Innovation Dr.

More information

General Specifications

General Specifications General Specifications WG41F11C Compact O Frame GS 14M04B10-20E-Z1 [Style: S1] Overview The WG41F11C Compact O frame is a space-saving frame designed for coating lines of battery electrode sheets. This

More information

ADVANCED OPTICAL FIBER SOLUTIONS

ADVANCED OPTICAL FIBER SOLUTIONS Fiber Laser Building Blocks Fiber Laser Cavities and All-Fiber Beam Combiners A Furukawa Company www.ofsoptics.com ADVANCED OPTICAL FIBER SOLUTIONS for Your Next Multi-Kilowatt Fiber Laser Applications

More information

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source Agilent 83437A Agilent 83438A Erbium ASE Source Product Overview H Incoherent light sources for single-mode component and sub-system characterization The Technology 2 The Agilent Technologies 83437A (BBLS)

More information

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors) More Precision scancontrol // 2D/D laser scanner (laser profile sensors) 12 scancontrol 29x gapcontrol 29x1 Technical details and versions - z-axis measuring range up to 265mm - x-axis measuring range

More information

XC-77 (EIA), XC-77CE (CCIR)

XC-77 (EIA), XC-77CE (CCIR) XC-77 (EIA), XC-77CE (CCIR) Monochrome machine vision video camera modules. 1. Outline The XC-77/77CE is a monochrome video camera module designed for the industrial market. The camera is equipped with

More information

Agilent 81600B Tunable Laser Source Family

Agilent 81600B Tunable Laser Source Family Agilent 81600B Tunable Laser Source Family Technical Specifications August 2007 The Agilent 81600B Tunable Laser Source Family offers the full wavelength range from 1260 nm to 1640 nm with the minimum

More information

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator)

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator) POWER LCOS-SLM CONTROLLER RESET POWER OUTPUT ERROR LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator) Control your light! Shape your beam! Improve your image! The devices are a reflective type

More information

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output! New model: 1260 1375 nm, low SSE output! Agilent Tunable Laser Source Family Technical Specifications August 2004 The Agilent Tunable Laser Source Family offers the from 1260 nm to 1640 nm with the minimum

More information

OTS-300 Express Series Power Meters/Sources and Testers

OTS-300 Express Series Power Meters/Sources and Testers OTS-300 Express Series includes intelligent, versatile optical meters, sources, and testers that simultaneously test and store dual wavelength attenuation measurements. At the press of a button, dual wavelength

More information

Digital SWIR Scanning Laser Doppler Vibrometer

Digital SWIR Scanning Laser Doppler Vibrometer Digital SWIR Scanning Laser Doppler Vibrometer Scan-Series OptoMET Scanning SWIR Laser Doppler Vibrometer (SLDV) is used for non-contact measurement, visualization and analysis of structural vibrations.

More information

MAP Optical Power Meter Module (mopm-b1)

MAP Optical Power Meter Module (mopm-b1) COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MAP Optical Power Meter Module (mopm-b1) Key Features Panel mount or remote head configuration Single, dual, or quad channel configurations available 250 khz

More information

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2.

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2. Overview 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK 1. Power connector 3. Security lock slot 2. VGA Brazil Version 1 April 20, 2018 Page 1 Model: 2XM32AA Panel Type 18.5-inch TN Viewable Image

More information

Light Source. Specification & User Manual

Light Source. Specification & User Manual Light Source Specification & User Manual Page 1 of 11 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar

More information

CMA4000i Optical Test System

CMA4000i Optical Test System CMA000i Optical Test System The CMA000i Optical Test System is an all-in-one test and measurement solution for network commissioning, fault location/restoration, maintenance, and DWDM spectral analysis.

More information

013-RD

013-RD Engineering Note Topic: Product Affected: JAZ-PX Lamp Module Jaz Date Issued: 08/27/2010 Description The Jaz PX lamp is a pulsed, short arc xenon lamp for UV-VIS applications such as absorbance, bioreflectance,

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

25W 9xxnm Uncooled Multimode Laser Diode Module

25W 9xxnm Uncooled Multimode Laser Diode Module 25W 9xxnm Uncooled Multimode Laser Diode Module BMU25-9xx-01/02-R Features: Single emitter based laser diode module High output power of 25W 0.15NA or 0.22NA 105μm core multimode optical fiber Hermetically

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) For more information about Agilent Technologies test and measurement products, applications, services, and for a current

More information

Measurement of Microdisplays at NPL

Measurement of Microdisplays at NPL Conference on Microdisplays Measurement of Microdisplays at NPL Christine Wall, Dr Julie Taylor, Colin Campbell 14 th Sept 2001 Overview Displays measurement at NPL Why measure microdisplays? Measurement

More information

Scanning System S-2100

Scanning System S-2100 2D laser measurement system The fastest 2D laser measurement system in the world 119 m range Scan rate >1 million points/sec 360 vertical field of view System description The PENTAX Scanning System S-2100

More information

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE ? 8 LCD Screen? 10.4 LCD Screen LCD Zoom Microscope Instruction Manual Please read the Instruction Manual carefully before installation and keep it for future

More information

ivw-ud322 / ivw-ud322f

ivw-ud322 / ivw-ud322f ivw-ud322 / ivw-ud322f Video Wall Controller Supports 2 x 2, 2 x 1, 3 x 1, 1 x 3, 4 x 1 & 1 x 4 Video Wall Array User Manual Rev. 1.01 i Notice Thank you for choosing inds products! This user manual provides

More information

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications OPTICAL SPECTRUM ANALYZER 600 to 750 nm GPIB High Performance for DWDM Optical Communications The is a diffraction-grating spectrum analyzer for analyzing optical spectra in the 600 to 750 nm wavelength

More information

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM PTY. LTD A.B.N. 83 003 020 504 OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM Document

More information

Standard Operating Procedure of nanoir2-s

Standard Operating Procedure of nanoir2-s Standard Operating Procedure of nanoir2-s The Anasys nanoir2 system is the AFM-based nanoscale infrared (IR) spectrometer, which has a patented technique based on photothermal induced resonance (PTIR),

More information

Steady-Lite Model 13plus Variable Intensity Fluorescent Illuminator High Frequency (85 khz) - Lite Mite Series

Steady-Lite Model 13plus Variable Intensity Fluorescent Illuminator High Frequency (85 khz) - Lite Mite Series Illumination Steady-Lite Model 13plus Variable Intensity Fluorescent Illuminator High Frequency (85 khz) - Lite Mite Series FEATURES: Uniform, shadow-free illumination High light output and color rendition

More information

Lensed Fibers & Tapered Ends Description:

Lensed Fibers & Tapered Ends Description: Lensed Fibers & Tapered Ends Description: LaseOptics Corporation ( LaseOptics ) has been producing next generation optical lensed fibers. LaseOptics Lensed Optical Fibers technology is proprietary integrated

More information

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera PRELIMINARY POWER DETECTORS ENERGY DETECTORS MONITORS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS CMOS Beam Profiling Camera AVAILABLE MODEL Beamage 3.0 (⅔ in CMOS

More information

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules MTS/T-BERD platform Applications Provisioning and maintenance of ROADM networks Commissioning of DWDM

More information

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat WaveNow USB Potentiostat / Galvanostat WaveNow / WaveNowXV Portable USB Potentiostat WaveNano Low-Current Portable USB Potentiostat Part Numbers Product Name WaveNow WaveNano WaveNowXV Description Portable

More information

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating /A Electronic Signal Data Logger Contents: Product Applications and Useful Features Product Transmitter / DicksonWare Software Product Frequently Asked Questions Warranty / Software & FAQs & Product Applications

More information

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Applications Academic/Education Design, development and manufacturing of passive and active

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

Video Digital Optical Converter

Video Digital Optical Converter Video Digital Optical Converter Model : W-VD1 AD Model : W-VD2 AD Model : W-VD4 AD Model : W-VD8 AD Video Digital Optical Converter adopt the advanced international digital video and optical fiber transmission

More information

Optical Perfection. HIGHYAG Beam Delivery Products

Optical Perfection. HIGHYAG Beam Delivery Products Optical Perfection HIGHYAG Beam Delivery Products At a Glance HIGHYAG Beam Delivery Products HIGHYAG beam delivery products for 1 µ lasers - from the beam launching unit at the laser via the laser light

More information

Click to Print This Page. 9,500 ANSI / 10,500 ISO Lumens Contrast Ratio: 10,000:1 (Dynamic Black) 1,000:1 native Part Number:

Click to Print This Page. 9,500 ANSI / 10,500 ISO Lumens Contrast Ratio: 10,000:1 (Dynamic Black) 1,000:1 native Part Number: Digital Projection Projector Specification Click to Print This Page Specification Sheet E-Vision Laser 0K 9,500 ANSI / 0,500 ISO Lumens Contrast Ratio: 0,000: (Dynamic Black),000: native Part Number: 8-060

More information

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software APPLICATION NOTE Fiber Alignment Now Achievable with Commercial Software 55 Fiber Alignment Now Achievable with Commercial Software Fiber Alignment Fiber (or optical) alignment s goal is to find the location

More information

Digital SWIR Scanning Laser Doppler Vibrometer

Digital SWIR Scanning Laser Doppler Vibrometer Digital SWIR Scanning Laser Doppler Vibrometer Scan-Series OptoMET Scanning SWIR Laser Doppler Vibrometer (SLDV) is used for non-contact measurement, visualization and analysis of structural vibrations.

More information

High performance optical blending solutions

High performance optical blending solutions High performance optical blending solutions WHY OPTICAL BLENDING? Essentially it is all about preservation of display dynamic range. Where projected images overlap in a multi-projector display, common

More information

Mahdad Manavi LOTS Technology, Inc.

Mahdad Manavi LOTS Technology, Inc. Presented by Mahdad Manavi LOTS Technology, Inc. 1 Authors: Mahdad Manavi, Aaron Wegner, Qi-Ze Shu, Yeou-Yen Cheng Special Thanks to: Dan Soo, William Oakley 2 25 MB/sec. user data transfer rate for both

More information

More Precision. confocaldt // Confocal chromatic measuring system

More Precision. confocaldt // Confocal chromatic measuring system More Precision confocaldt // Confocal chromatic measuring system Confocal chromatic sensors for displacement and thickness confocaldt IFS206 / IFS207 IFS206-/VAC(001) IFS206-/VAC(001) IFS206/90-/VAC(001)

More information

Multicolor Scan Laser Photocoagulator MC-500 Vixi

Multicolor Scan Laser Photocoagulator MC-500 Vixi Multicolor Scan Laser Photocoagulator MC-500 Vixi MC-500 The Versatile Laser Photocoagulator Selectable configuration of laser colors and delivery units Multiple scan patterns Enhanced usability LPM (Low

More information

Optical Engine Reference Design for DLP3010 Digital Micromirror Device

Optical Engine Reference Design for DLP3010 Digital Micromirror Device Application Report Optical Engine Reference Design for DLP3010 Digital Micromirror Device Zhongyan Sheng ABSTRACT This application note provides a reference design for an optical engine. The design features

More information

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach NEW DRS: Incremental encoders, number of lines and zero pulse width freely programmable DRS: s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS. GENERAL. A.) Overview. SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS. 1.) The luminaire shall be a color mixing luminaire employing twenty-four (24) red, green, blue, and white LED engines.

More information

MTS/T-BERD 8000 Platform

MTS/T-BERD 8000 Platform Key Features New optical design for field applications 50% reduction in size and weight for true OSNR measurements in ROADM networks Full spectral range of 1250 to 1650 nm for DWDM and CWDM testing High-resolution

More information

TIL311 HEXADECIMAL DISPLAY WITH LOGIC

TIL311 HEXADECIMAL DISPLAY WITH LOGIC TIL311 Internal TTL MSI IC with Latch, Decoder, and Driver 0.300-Inch (7,62-mm) Character Height Wide Viewing Angle High Brightness Left-and-Right-Hand Decimals Constant-Current Drive for Hexadecimal Characters

More information

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full. TENDER SPECIFICATIONS FOR THE SUPPLY, DELIVERY, INSTALLATION AND COMMISSIONING OF ONE UNIT OF VARIABLE PRESSURE ENVIRONMENTAL SCANNING ELECTRON MICROSCOPE (SEM) CUM ENERGY DISPERSIVE SPECTROSCOPY (EDS)

More information

4-channel HDMI Network Extender

4-channel HDMI Network Extender RoHS 4-channel HDMI Network Extender Ver..3. (80608) The are a 4-channel HDMI network transmitter and receiver set having a built-in scan converter and scaler. This extender transmits 4-channel HDMI signal

More information

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement A worldwide leader in precision measurement solutions MTI-2100 FOTONIC SENSOR High resolution, non-contact measurement of vibration and displacement MTI-2100 Fotonic TM Sensor Unmatched Resolution and

More information

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94 LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94 Colour balance alignment of LCD/EL displays Optical system for spot measurements High

More information

Driver circuit for CCD linear image sensor

Driver circuit for CCD linear image sensor Driver circuit for CCD linear image sensor C11165-01 For CCD image sensor (S11155/S11156-2048-01) The C11165-01 is a driver circuit designed for HAMAMATSU CCD image sensor S11155/S11156-2048-01. The C11165-01

More information

More Precision. confocaldt // Confocal chromatic measuring system

More Precision. confocaldt // Confocal chromatic measuring system More Precision confocaldt // Confocal chromatic measuring system Confocal chromatic sensors for displacement and thickness confocaldt IFS206 / IFS207 IFS206-/VAC(001) IFS206-/VAC(001) IFS206/90-/VAC(001)

More information

PSM-003. Micro Polarization Controller/Scrambler. User Guide

PSM-003. Micro Polarization Controller/Scrambler. User Guide PSM-003 Micro Polarization Controller/Scrambler User Guide Version: 1.0 Date: August 23, 2012 General Photonics, Incorporated is located in Chino California. For more information visit the company's website

More information

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS. SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS. GENERAL. A.) Overview. 1.) The luminaire shall be a color mixing luminaire employing nine (19) homogenized red, green, blue, and white LED engines.

More information

LASER SCANNING PRODUCT GUIDE. Industrial Holographic and Conventional Laser 1D, Omnidirectional Bar Code Scanners

LASER SCANNING PRODUCT GUIDE. Industrial Holographic and Conventional Laser 1D, Omnidirectional Bar Code Scanners LASER SCANNING PRODUCT GUIDE Industrial Holographic and Conventional Laser 1D, Omnidirectional Bar Code Scanners 1D PRODUCT IS8550 - IS8500 - Contents Selection Guide and Specifications 1-2 IS8000 Series

More information

Altman Lighting AP-150 RGBW Par Specification

Altman Lighting AP-150 RGBW Par Specification 1.01 COLOR MIXING LED WASH FIXTURE A. General 1. The fixture shall be Red, Green, Blue, and White LED luminaire with motorized zoom and DMX control. The fixture shall be the AP-150 RGBW by Altman Stage

More information

Prisma Optical Networks Ancillary Modules

Prisma Optical Networks Ancillary Modules Optoelectronics Prisma Optical Networks Ancillary Modules Description The Prisma platform is capable of utilizing a combination of modules which address a variety of revenue generating applications. The

More information

E4416A EPM-P Series Single Channel Power Meter

E4416A EPM-P Series Single Channel Power Meter United States Home >... > Power Meters & Power Sensors > EPM and EPM-P Series Power Meters > E4416A EPM-P Series Single Channel Power Meter Product Status: Currently Orderable Currently Supported Key Specifications

More information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Installation. SAPTF33xx-1xx in the Network. Standard Configuration SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device

More information

iqs-1600/iqs-1700/ohs-1700 POWER METER AND OPTICAL HEAD SERIES

iqs-1600/iqs-1700/ohs-1700 POWER METER AND OPTICAL HEAD SERIES iqs-1600/iqs-1700/ohs-1700 POWER METER AND OPTICAL HEAD SERIES Fast, accurate, flexible power measurement in a platform-based solution. spec sheet Key Features Wide selection of power meter options, to

More information