C E R T I F I C A T E O F C O M P L I A N C E

Size: px
Start display at page:

Download "C E R T I F I C A T E O F C O M P L I A N C E"

Transcription

1 JG Frame, Types NJGA, HJGA and LJGA. These are two and three pole circuit breakers with interchangeable thermal magnetic and electronic trip units. They are uncompensated 40 o C construction rated A, 600 V ac, 250 V dc (two pole) and 500 V dc (three pole for ungrounded UPS systems). Circuit breakers with electronic trip units are not marked with dc ratings. These circuit breakers may be marked for 100% continuous current, and HACR Type.. Current interrupting ratings are as follows: Voltage Poles Ratings Type NJGA Type HJGA Type LJGA 240 ac, 50/60 Hz 2,3 65 ka 100 ka 200 ka 480 ac, 50/60 Hz 2,3 35 ka 65 ka 100 ka 600 ac. 50/60 Hz 2,3 25 ka 25 ka 25 ka 250 dc 2 30 ka 30 ka 30 ka 500 dc 3 25 ka 35 ka 35 ka

2 Report Reference E10848, 2006 January 19 JG Frame, Type HJMA. Three pole, rated 400A, 600 V ac, 250 V dc.

3 Certificate Number E68312 Report Reference E68312, 2006 January 20 Molded Case Switch JG Frame, Type HJGA and LJGA. Two and three pole, rated 400A, 600V ac, 250 V dc. Does not provide overcurrent protection. This switch is suitable for use on a circuit capable of delivering not more than: Voltage Max RMS Symm. Amp Type HJGA Type LJGA 240 ac, 50/60 Hz 100 ka 200 ka 480 ac, 50/60 Hz 65 ka 100 ka 600 ac. 50/60 Hz 25 ka 25 ka 250 dc 30 ka 30 ka When protected by a fuse or circuit breaker, rated 400A maximum. May open circuit above 5500 A., CAN/CSA-C22.2 No. 5 (2002), Molded-Case Circuit Breakers, Molded-Case Switches and. Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with C and US identifiers: the word LISTED ; a control number (may be alphanumeric) assigned by UL; and the product category

4 JG Frame, Types NJGA4, HJGA4 and LJGA4 These are four pole circuit breakers with interchangeable thermal magnetic trip units. They are uncompensated 40 o C construction rated A, 600 V ac. The neutral pole does not have overcurrent protection. Current interrupting ratings are as follows: Voltage Poles Ratings Type NJGA4 Type HJGA4 Type LJGA4 240 ac, 50/60 Hz 2,3 65 ka 100 ka 200 ka 480 ac, 50/60 Hz 2,3 35 ka 65 ka 100 ka 600 ac. 50/60 Hz 2,3 25 ka 25 ka 25 ka

5 JG Frame, Type NJJA. These are two and three pole circuit breakers with non-interchangeable thermal magnetic trip units. They are uncompensated 40 o C construction rated A, 240 V ac, 250 V dc (two pole). These circuit breakers may be marked HACR Type Current interrupting ratings are as follows: Voltage Poles Ratings Type NJJA 240 ac, 50/60 Hz 2,3 65 ka 250 dc 2 30 ka

6 JG Frame, Type HJGD. These are complete three pole circuit breakers with thermal magnetic trip units. They are uncompensated 40 o C construction rated A, 600 V dc. These circuit breakers may be marked HACR Type. Current interrupting ratings are as follows 65 ka, 600 Vdc and CAN/CSA-C22.2 No. 5, Molded-Case Circuit Breakers, Molded-Case Switches and Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with C and US identifiers: the word LISTED ; a control number (may be alphanumeric) assigned by UL; and the product category

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Power Circuit of a UL508A Panel. Typical UL489 Application

Power Circuit of a UL508A Panel. Typical UL489 Application Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech

More information

Type MG-6 Auxiliary Relay Class 1E

Type MG-6 Auxiliary Relay Class 1E Type MG-6 Auxiliary Relay Class 1E Product Guide Device Number: 94X, Y, Z ZPA Rating 4.2g ABB Application MG-6 relays have been specially designed and tested to establish their suitability for Class 1E

More information

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS File E322469 Project 4786125262 December 11, 2013 REPORT On DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS Lutron Electronics Co Inc Coopersburg, Pa Copyright 2013 UL LLC UL LLC authorizes

More information

AUTOMATIC TRANSFER SWITCHES. Product Guide

AUTOMATIC TRANSFER SWITCHES. Product Guide AUTOMATIC TRANSFER SWITCHES Product Guide CUSTOM CONFIGURATION The chart tells the story. You can custom configure switches by choosing the exact components needed. This standard process allows Kohler

More information

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3 PowerPact Multistandard Catalogue numbers Functions and characteristics A-1 Installation recommendations B-1 Dimensions C-1 Wiring diagrams D-1 Additionals characteristics E-1 H-Frame, J-Frame unit-mount

More information

Digital output modules

Digital output modules Appendix 374 Digital output modules Order number Figure Type DO 8xDC 24V 2A DO 16xDC 24V 1A DO 16xDC 24V 2A DO 16xDC 24V 0.5A manual operation General information Note - - - - Features 8 outputs, in groups

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz. HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.

More information

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection... IEC ors and Starters. Contents Description Catalog Number Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications..........

More information

Type: DILM12 10(24VDC) Article No.:

Type: DILM12 10(24VDC) Article No.: Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals Product datasheet Characteristics GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - spring terminals Main Range Product name Device short name Product or component type Device application

More information

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles

More information

llen-bradley 194R-HM4-NFPA3

llen-bradley 194R-HM4-NFPA3 Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main. Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main. Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

GV2ME. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application Product datasheet Characteristics GV2ME32 TeSys GV2-Circuit breaker-thermal-magnetic - 24...32 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology

More information

GV2P05. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application Product datasheet Characteristics GV2P05 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2P Circuit breaker Motor Thermal-magnetic

More information

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2 AC Voltage Range¹ / resolution 2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 khz 2.0% + 3 600.0 mv / 0.1 mv 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V 1. All AC voltage ranges are specified

More information

GP-500 SERIES - Low Voltage

GP-500 SERIES - Low Voltage M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete motor protection solution by

More information

XT IEC Power Control Combination Motor Controllers

XT IEC Power Control Combination Motor Controllers 7 Product Family Overview May 007 Contents Description Page Standards and Certifications............. 7 Catalog Selection................ 76 Product Selection.......... 77 Accessories............... 7

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100 DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective

More information

File E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised:

File E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised: File E64388 Vol. 1 Sec. 106 Page 1 Issued: 1993-11-08 and Report Revised: 2011-06-01 DESCRIPTION PRODUCT COVERED: USR; Component - Appliance Filter, Models FN261#W-Y-XX-ZZ, FN9260#W-Y-XX- ZZ, FN9263#W-Y-XX-ZZ,

More information

PRINCIPLES AND APPLICATIONS

PRINCIPLES AND APPLICATIONS GENERATION & NETWORK Digital Automation Measuring and Control Devices AMS7000 PROCOM The optimum operation of an electrical network depends particularly on the reliability and the availability of the protection,

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63 Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC

More information

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM25 10(24V50HZ) Article No.: Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

GV2ME. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application Product datasheet Characteristics GV2ME10 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2ME Circuit breaker Motor Thermal-magnetic

More information

Kinetix Application Note

Kinetix Application Note Applying 2094 LIM Modules to Multiple Loads Kinetix Application Note PURPOSE This document addresses application cases where it is desired to utilize a single 2094 LIM module to supply three phase power

More information

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release

More information

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A. CURRENT INJECTION RELAY TESTER CR-100 ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M 981 329 / 05A ) (c) CIRCUTOR S.A. ---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 2 CURRENT INJECTION

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

TeSys circuit-breakers

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping

More information

Magnum Panel Systems. UL1741 Interconnection System Equipment. The Powerful Difference

Magnum Panel Systems. UL1741 Interconnection System Equipment. The Powerful Difference Magnum Panel Systems UL1741 Interconnection System Equipment The Powerful Difference MMP Mini Magnum Panel The MMP Enclosure The MMP shown with inverter (sold separately) and optional remote and backplate.

More information

A V 50Hz / V 60Hz

A V 50Hz / V 60Hz A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V

More information

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS Copyright 2013 UL LLC File E322469 Project 4786125262 December 11, 2013 REPORT On DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS Lutron Electronics Co Inc Coopersburg, Pa UL LLC authorizes

More information

GR circuit breaker - hydraulic magnetic, Datasheet

GR circuit breaker - hydraulic magnetic, Datasheet GR circuit breaker - hydraulic magnetic, Datasheet railway, 35 mm rail Description Compact hydraulic magnetic circuit breaker for railway applications, to protect electronic equipment and components against

More information

Active UTP Transceiver Hub Installation Guide

Active UTP Transceiver Hub Installation Guide Active UTP Transceiver Hub Installation Guide Models Include: HubWayEX16 - Sixteen (16) Channels - Thirty-two (32) Channels Rev. 011810 More than just power. TM Overview: Altronix HubWayEX16/EX32 Active

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control IEC Contactors and Starters. Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

3AH3 Vacuum Circuit-Breakers

3AH3 Vacuum Circuit-Breakers Catalog HG 11.03 Edition 2018 3AH3 Vacuum Circuit-Breakers Medium-Voltage Equipment siemens.com/3ah3 2 3AH3 Vacuum Circuit-Breakers Siemens HG 11.03 2018 R-HG11-373.tif Contents 3AH3 Vacuum Circuit-Breakers

More information

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

CAMTO LTD. Arc detecting system DC/AC

CAMTO LTD. Arc detecting system DC/AC CAMTO LTD Arc detecting system DC/AC Arc detecting system DC/AC The system is based on experience with arc protection since 1962. The system units are built into boxes that all fit on a 35 mm DIN-rail.

More information

Switching Power Module

Switching Power Module Assembled in U.S.A. 5005757 Rev. A GCU-HOSP 243C ID. COT. EQ. IEC PEV /EC Class 2 +.800.523.9466 + 44.(0)20.7680.448 HomeWorks DI Power odule Switching Power odule The Switching Power odule family is a

More information

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100 Circuit-breaker,3p,400A Partno. LZMC3-A400-I Articleno. 111955 Similar to illustration Deliveryprogramme Product range Circuit-breaker Protective function System and cable protection Standard/Approval

More information

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View) 30A 400A (30 200A Load Breaking), Maximum 600VAC/250VDC Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion-Proof Interlocked Receptacles Cast Aluminum Circuit Breaker Interlocked

More information

COHERENCE ONE PREAMPLIFIER

COHERENCE ONE PREAMPLIFIER COHERENCE ONE PREAMPLIFIER OWNER S MANUAL TABLE OF CONTENTS Introduction Features Unpacking Instructions Installation Phono Cartridge Loading Basic Troubleshooting Technical Specifications Introduction

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air

More information

GR circuit breaker - hydraulic magnetic, Datasheet

GR circuit breaker - hydraulic magnetic, Datasheet GR circuit breaker - hydraulic magnetic, Datasheet railway, 35 mm rail Description Compact hydraulic magnetic circuit breaker for railway applications, to protect electronic equipment and components against

More information

Intertie Protection M 3520

Intertie Protection M 3520 PROTECTION Intertie Protection M 3520 Integrated Protection System Unit shown with optional HMI and Target modules Integrated Protection System for DR/DG Intertie, Providing: Loss of parallel utility operation

More information

EMC Solutions Noise filtering

EMC Solutions Noise filtering Power & Signal Quality TRABTECH EMC Solutions Noise filtering Interference-free power supply and signal transmission A permanent supply and safe data link are essential for the operational reliability

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I

More information

PRELIMINARY Sunny Boy 240-US

PRELIMINARY Sunny Boy 240-US PRELIMINARY Sunny Boy 240-US SB 240-US-10 Optimized reliability Simple installation Unrivaled monitoring SMA-backed security Multigate technology allows for reduced component count Private band powerline

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Manual Motor Protectors Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays....................

More information

Product Discontinuation Notices. Discontinuation Notice of built-in Power Supply Photoelectric sensors E3B2 series

Product Discontinuation Notices. Discontinuation Notice of built-in Power Supply Photoelectric sensors E3B2 series PRODUCT NEWS Product Discontinuation Notices March 1, 2011 Photoelectric Sensors No. 2011E011 Discontinuation Notice of built-in Power Supply Photoelectric sensors E3B2 series Product Discontinuation E3B2-D2

More information

KRF EMC Filters Installation, Operation and Maintenance Manual

KRF EMC Filters Installation, Operation and Maintenance Manual KRF EMC Filters Installation, Operation and Maintenance Manual KRF EMC Filters limit high frequency noise, as well as: Reduce interference Protect sensitive equipment Eliminate drive cross-talk Meet FCC

More information

STEVAL-ISA001V1. 6W Dual Output Supply using VIPer12A. Features. Blue angel. Applications

STEVAL-ISA001V1. 6W Dual Output Supply using VIPer12A. Features. Blue angel. Applications Features Switch mode General Purpose Power Supply Input: 85 to 264 VAC @ 50/60 Hz Output: 12V @ 0.5A Output Power (peak) 6W Burst Mode Operation in Standby for Blue Angel operation Current Mode Control

More information

Minicontactorrelay,2NO/2NC,DCoperated

Minicontactorrelay,2NO/2NC,DCoperated Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique

More information

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide

More information

Hypnotica is Color Changing Series

Hypnotica is Color Changing Series PRODUCT SUMMARY PRODUCT FEATURES Slender, low profile Smooth, even light output Compatible with any 512 controller or any RDM (Remote Device Mangement) controller Controllable in 6 increments Applications:

More information

Split System Air Conditioner

Split System Air Conditioner Residential & Light Commercial HVAC Split System Air Conditioner 1 R-410A, 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 2 to 5 tons

More information

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories Circuit Breakers BZM Product Information Circuit Breaker BZM1 16 to 125 A Circuit Breaker BZM2 125 to 250A BZM1 & BZM2 Accessories Circuit breakers BZM1 3-pole Rated current Short circuit Basic switching

More information

Medium and High Voltage Circuit Breakers Characteristic Time Quantities of the Circuit Breaker with Applications

Medium and High Voltage Circuit Breakers Characteristic Time Quantities of the Circuit Breaker with Applications Workshop 6: Maintenance and monitoring Medium and High Voltage Circuit Breakers Characteristic Time Quantities of the Circuit Breaker with Applications Alexander Herrera OMICRON electronics GmbH 3 December

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES COMPANY INTRODUCTION Bridex Singapore Pte Ltd is founded in 1978 as a manufacturer of instruments transformer for the Asian market. We are the first local electrical switchgear

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2008-05-07 Page 1 of 8 Report Reference # E320635-A1-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

Data Sheet Definite Purpose Contactors Ex9CK Series

Data Sheet Definite Purpose Contactors Ex9CK Series Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed

More information

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator EA63-7D Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 -

More information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat4D - Four (4) Channel Passive UTP Transceiver Hub with Integral HubSat42D - Four (4) Channel Passive UTP Transceiver includes

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

Toronto Hydro - Electric System

Toronto Hydro - Electric System Toronto Hydro - Electric System FIT Commissioning Requirements and Reports Comments and inquiries can be e-mailed to: FIT@torontohydro.com Customers without e-mail access can submit through regular mail

More information

BE3-GPR GENERATOR PROTECTIVE RELAY

BE3-GPR GENERATOR PROTECTIVE RELAY BE3-GPR GENERATOR PROTECTIVE RELAY Behind-the-Panel Mounting Semi-flush Mounting Basler Electric s BE3-GPR generator protective relay offers multiple protective features in a single package. Its microprocessor-based

More information

DSP 18 Sub active subwoofer. user manual

DSP 18 Sub active subwoofer. user manual DSP 18 Sub active subwoofer user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 05.11.2018,

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

Type Contact form Model

Type Contact form Model Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori Podatkovni list proizvoda Karakteristike GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori Glavno Range Product name Device short name Product or component type Device application

More information

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1) 80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1843470 Issued to: Hypertherm, Incorporated 21 Great Hollow Rd Hanover, New Hampshire 03755 USA Attention: Bobbie-Jeanne Wheeler The products listed below are eligible

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

EA350. Generator Automatic Voltage Regulator Operation Manual

EA350. Generator Automatic Voltage Regulator Operation Manual Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator For General Generators Compatible with Marathon SE350* * Use for reference purpose only and not a genuine

More information

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications.

More information