Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.

Size: px
Start display at page:

Download "Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals."

Transcription

1 NSB00 K ) K ) K ) Auxiliary switch block, Contactors,. kw RT RT RT / front RH-... /0 Contactors,. kw RT RT RT / Surge suppressors RT /, / auxiliary switch block, -phase feeder front RT -G. / terminals RA -K Auxiliary switch block with unassigned NO contact RH -BA /0 Assembly kit RA -B The assembly kit contains: Mechanical interlock connecting clips Wiring modules on the top and bottom for connecting the main and control conducting paths ) Use version with NO. ) Use version with NC.

2 NSB0_00b K K K Mechanical interlock, lateral RA -B / Contactors, kw RT RT RT / auxiliary switch block, front ) Contactors, /. kw RT RT RT / RT -G... / Timing relay, lateral RP -N.0 ) Mechanical interlock, front RA -A / Auxiliary switch block with Auxiliary switch block, lateral RH -EA.. / unassigned NO contact RH -CA / Surge suppressors RT / Auxiliary switch block for -phase feeder terminal ) RV -A -phase busbar ) RT -CC0 - units RH -CA0 Push-in lug ) - units RH -CA / for timing relay RP 0 ) Assembly kit RA -B The assembly kit contains: ) Generally possible. If a solid-state time-delay auxiliary switch block is mounted onto the front of K, a standard auxiliary switch block can only be ) and can only be mounted with contactors with screw terminal (coil). Connecting clips Wiring modules on the top and bottom for connecting the main and control conducting paths ) Not included in the scope of supply of the preassembled contactor assemblies; ) See "Monitoring and Control Devices: RP, PV Timing Relays --> RP Timing Relays in Industrial Enclosure,. mm".

3 NSB0_00c K K K Mechanical interlock, lateral Contactors, /0 kw RT RT RT / Depth compensation required K:. mm; K: 0 mm ) Timing relay, lateral RP -N.0 ) RA -B / Auxiliary switch block with auxiliary switch block, front ) unassigned NO contact RH -CA / RT -G... / Auxiliary switch block for Auxiliary switch block, lateral RH -EA.. / Surge suppressors RT /, - units RH -CA0 RT / - units RH -CA / RV -A Base plate RA -E RV -A Assembly kit RA -C -phase feeder terminals -phase busbars Push-in lug ) for timing relay RP 0 ) Use the RA -B base plate for this configuration. ) Generally possible. If a solid-state time-delay auxiliary switch block is mounted onto the front of K, a standard auxiliary switch block can only be ) Not included in the scope of supply of the preassembled contactor assemblies; ) See "Monitoring and Control Devices: RP, PV Timing Relays --> RP Timing Relays in Industrial Enclosure,. mm". )

4 NSB0_00b K K K Mechanical interlock, lateral RA -B / Contactors, kw Contactors, kw RT RT RT RT RT RT / / auxiliary switch block, front ) RP -N.0 ) Mechanical interlock, front Auxiliary switch block, lateral RH -CA / Surge suppressors -phase feeder terminals -phase busbars Push-in lug ) for timing relay RT -G... RA -A RH -EA.. RT RT RV -A RV -A RP 0 / / / /, / ) Generally possible. If a solid-state time-delay auxiliary switch block is mounted onto the front of K, a standard auxiliary switch block can only be ) Timing relay, lateral Auxiliary switch block with unassigned NO contact Auxiliary switch block for - units - units Base plate Assembly kit RH -CA0 RH -CA RA -F RA -B / ) Not included in the scope of supply of the preassembled contactor assemblies; ) See "Monitoring and Control Devices: RP, PV Timing Relays --> RP Timing Relays in Industrial Enclosure,. mm".

5 0 NSB0_00e K K K Mechanical interlock, lateral Depth compensation required RA -B / Contactors, kw Contactors, kw RT RT RT RT RT RT / / K: 0 mm; K:. mm ) Timing relay, lateral RP -N.0 ) auxiliary switch block, front ) Auxiliary switch block with RT -G... / unassigned NO contact RH -CA / Auxiliary switch block, lateral Surge suppressors RH -EA.. RT.-... / / Auxiliary switch block for Push-in lug ) for timing relay - units RH -CA0 RP 0 ) - units RH -CA / 0 -phase feeder terminals RA -L Base plate RA -E Assembly kit RA -C ) Use the RA -B base plate for this configuration. ) Generally possible. If a solid-state time-delay auxiliary switch block is mounted onto the front of K, a standard auxiliary switch block can only be ) Not included in the scope of supply of the preassembled contactor assemblies; ) See "Monitoring and Control Devices: RP, PV Timing Relays --> RP Timing Relays in Industrial Enclosure,. mm".

Selection guide siemens.com/sirius-modular-system

Selection guide siemens.com/sirius-modular-system SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Terminal designations according to EN 50 012 3RT10 1 contactors Ident. no. 10E 01 Sizes S0 to S12 Terminal designations according to EN 50 012 3RT10 2 to 3RT10 7, 3RT12, 3RT14 contactors 3RT10 1 contactors

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

TeSys circuit-breakers

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page 3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe EFC, EFCe Systems Electronic Frequency Control Continuously variable speed control using frequency converter technology With the EFC and EFCe system Bock offers the most efficient means of adapting the

More information

Bulletin 305 AC Starters

Bulletin 305 AC Starters Bulletin 305 AC Starters Bulletin 305 NEMA AC Starters NEMA sizes 0 2 Cost saving design E1 Plus electronic overload relays Compact size Bulletin 305 reversing starters are most commonly used for full-voltage

More information

Bulletin 509 Full Voltage

Bulletin 509 Full Voltage Bulletin 509 Full Voltage Example Cat. No. 509 B O D A2E 17 a b c d e f a Bulletin No. Bulletin No. 509 Top-wired starter 509DC Top-wired starter (DC voltage) b NEMA Size T 00 A 0 B 1 C 2 D 3 E 4 F 5 G

More information

Features XT SC 012 B B A

Features XT SC 012 B B A Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power

More information

Features XT SC 012 B B A

Features XT SC 012 B B A Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power

More information

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic

More information

XT IEC Power Control Combination Motor Controllers

XT IEC Power Control Combination Motor Controllers 7 Product Family Overview May 007 Contents Description Page Standards and Certifications............. 7 Catalog Selection................ 76 Product Selection.......... 77 Accessories............... 7

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

3-pole contactors for standard applications

3-pole contactors for standard applications PF511137R.eps PF511139R.eps PF511138R.eps LC1 K0910 LC1 K09103 3-pole contactors for standard applications Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 220 V 230 V 380 V 415 V 440/500

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

Bulletin 500 Top Wiring For Motor Loads

Bulletin 500 Top Wiring For Motor Loads Bulletin 500 Top Wiring For Motor Loads Product Selection of size 0 4 Modular Kits Base Contactor Includes a 120V AC coil and (1) N.O. auxiliary contactor as standard. Full Load Current Must Not Exceed

More information

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection... IEC ors and Starters. Contents Description Catalog Number Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications..........

More information

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1) 80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,

More information

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business

More information

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range

More information

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B 11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories

Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories Bulletin 100-M Miniature Contactors Compact Size Uniform Panel Mounting Dimensions Full oltage Non-Reversing and Reversing Contactors 5, 9, and 12 A Contactors Compatible with Bulletin 193-E solid-state

More information

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview. .1 Motor Control and Protection Product Overview Selection Guide Description Definite Purpose XT IEC Miniature XT IEC Page 65 Page 69 Page 71 Type Definite purpose IEC IEC Approvals UL Recognized, CSA,

More information

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,

More information

Fastbus Combination Starters. SIRIUS 3RA11 Fastbus Non-Reversing Combination Starters,

Fastbus Combination Starters. SIRIUS 3RA11 Fastbus Non-Reversing Combination Starters, Fastbus Combination Starters SIRIUS 3RA11 Fastbus Non-Reversing Combination Starters, otor Starter Protectors (MSP) SIRIUS3RV10MSP aeneral Description 3RV10 Motor Starter Protectors (MSP's) are built for

More information

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line... XT Line Replacement s.1 Freedom Line............................................ A200 Line............................................... Lighting Contactor Magnetic.2 IEC Contactors and Starters XT Line..................................................3

More information

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286 CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

Bulletin 190 Compact. Combination Starters

Bulletin 190 Compact. Combination Starters 0Circuit reaker ulletin 10 ulletin 10 Compact Combination Starters Power Range 0.1...45 ulletin 10E Modular Eco Starters ulletin 10S Pre-wired Compact Starters Uses ulletin 140M Motor Protectors and ulletin

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) XT RE C 10 B 22 AD

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) XT RE C 10 B 22 AD . Selection XT Relays Product Line Prefix XT = XT IEC power control XT Timers Product Line Prefix XT = XT IEC power control Product Family Code RM = Mini IEC control relay RE = IEC control relay Product

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

AC1036. Definite Purpose Contactors

AC1036. Definite Purpose Contactors Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous

More information

Minicontactorrelay,2NO/2NC,DCoperated

Minicontactorrelay,2NO/2NC,DCoperated Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique

More information

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control IEC Contactors and Starters. Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete

More information

Data Sheet Definite Purpose Contactors Ex9CK Series

Data Sheet Definite Purpose Contactors Ex9CK Series Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed

More information

Accessories. EasyPact and Vigi CVS100/160/ short LV long LV Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242

Accessories. EasyPact and Vigi CVS100/160/ short LV long LV Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242 Catalogue numbers Accessories CVS100/160/250 DB112225 2 short LV429235 2 long LV429236 DB112226 Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242 LV429243 DB112225 DB112726 Aluminium connectors

More information

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete motor protection solution by

More information

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem

More information

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...

More information

Bulletin 150, 154 Softstarters Quick Selection Table

Bulletin 150, 154 Softstarters Quick Selection Table Bulletin 50, 54 Quick Selection Table Type Current Range Bulletin No. 50 50 50 SMC-3 Controller 85 A SMC-Delta Controller 47 A SMC Flex Controller 54 480 A Soft Start Kickstart Current Limit Dual Ramp

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications

More information

Operating Manual RISH OPTIMA VAF

Operating Manual RISH OPTIMA VAF Operating Manual RISH OPTIMA VAF 2-60-006-00-00511_Rev. A - 5/2014 Section DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Digital Panel Meter Installation & Operating Instructions Contents

More information

HS-509 VIBRATION TRIP MODULE

HS-509 VIBRATION TRIP MODULE HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an

More information

2-output DALI controller

2-output DALI controller 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 -output DALI controller Page. Use.... Technical features... 3. Overall dimensions.... 4. Connection... 5. Installation...3

More information

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. On-Delay: Provides a delay period on energization, at the end of which the switch contacts transfer. De-energizing

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry. SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.

More information

Bulletin 100-G IEC Contactors

Bulletin 100-G IEC Contactors Bulletin 100-G IEC Contactors Bulletin 100 G IEC Contactors 315...710 kw, 400V 350 900 Hp, 460/575V 3-Pole contactors 4th add-on neutral switching pole AC and DC control Horizontal and vertical interlocking

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

Variable speed drives Altivar Process Three-phase supply voltage: V 50/60 Hz Wall-mounting drives

Variable speed drives Altivar Process Three-phase supply voltage: V 50/60 Hz Wall-mounting drives s Three-phase supply voltage: 200...240 V 50/60 Hz Wall-mounting drives ATV630D11M3 ATV630D15M3 ATV630D30M3 200...240 V IP 21/UL Type 1 drives Motor Line supply Power indicated on rating plate (2) Line

More information

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3 PowerPact Multistandard Catalogue numbers Functions and characteristics A-1 Installation recommendations B-1 Dimensions C-1 Wiring diagrams D-1 Additionals characteristics E-1 H-Frame, J-Frame unit-mount

More information

DMX and 4000 air circuit breakers from 800 to 4000 A

DMX and 4000 air circuit breakers from 800 to 4000 A DMX 3 20 and 00 air circuit breakers from 800 to 00 NEW 286 56 + 288 02 (p. 4) 286 4 + 288 02 (p. 4) 28 56 + 288 02 (p. 4) Dimensions (p. to 53) Electrical characteristics (p. 54 to 5) ir circuit breakers

More information

Bulletin 100-G IEC Contactors

Bulletin 100-G IEC Contactors Bulletin G IEC Contactors 315...710 kw, 400V 350 900 Hp, 460/575V 3-Pole contactors 4th add-on neutral switching pole AC and DC control Horizontal and vertical interlocking Mechanical latching Meets IEC,

More information

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm 21.610/1 RAK: Universal thermostat How energy efficiency is improved Demand-led controlling, monitoring and limiting, without auxiliary energy. Areas of application For controlling and monitoring the temperature

More information

SPECIAL SPECIFICATION 2344 TMC Support Equipment

SPECIAL SPECIFICATION 2344 TMC Support Equipment 2004 Specifications CSJ 0912-00-488 SPECIAL SPECIFICATION 2344 TMC Support Equipment 1. Description. Furnish Traffic Management Center (TMC) support equipment in the City of Missouri City TMC location

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I

More information

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The

More information

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control Series 3000 Model R-165A Audio/Video IF/RF Relay Panel Instruction Manual CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. Lyndonville NY 14098 www.monroe-electronics.com Table

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Definite Purpose Contactors

Definite Purpose Contactors Definite Purpose Contactors Your order must include: 1) complete cat. no. of selected contactor, and 2) auxiliary contacts, if required. 20/25 FLA 1 and 2 Pole 1-Pole Contactor with Shunt 2-Pole Contactor

More information

Sentinel I24 Digital Input and Output Configuration

Sentinel I24 Digital Input and Output Configuration Application Bulletin: #155 Date: October 19, 2007 Sentinel I24 Digital Input and Output Configuration The Sentinel I24 can communicate with external hardware using digital inputs and outputs. There are

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

Single sensor setup with NIVEL210

Single sensor setup with NIVEL210 Single sensor setup with NIVEL210 Essential Items: 576 198 NIVEL210 RS232 748 335 Cable, Lemo 0 power supply cable Lemo 1 802 902 Cable, Lemo 0 722 409 Power supply plus power cords 802 902 576 198 748

More information

DIN Power Module - Phase Adaptive

DIN Power Module - Phase Adaptive DIN Power Module ow Capacity Phase Adaptive DIN Power Module - Phase Adaptive 369849a 1 08.06.15 The Phase Adaptive Power Module family is a group of modular products for the control of lighting loads.

More information

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance NEW Safety Light Curtain MS4800 Series Strong, Durable Body and Long, 20-m Sensing Distance A Powerful Safety Light Curtain with Durable, Impact-resistant Body and Long, 20-m Sensing Distance Has Arrived.

More information

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

Manual Version Audio/Video Switchers. AV4x1P AV8x1P AV8x1A

Manual Version Audio/Video Switchers. AV4x1P AV8x1P AV8x1A AV4x1P AV8x1P AV8x1A Audio/Video Switchers Manual Version 2.01 BURST ELECTRONICS INC ALBUQUERQUE, NM 87109 USA (505) 898-1455 VOICE (505) 890-8926 TECH SUPPORT Made in USA (505) 898-0159 FAX www.burstelectronics.com

More information

Safety Light Curtains GuardShield

Safety Light Curtains GuardShield Description The Allen-Bradley Guardmaster safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. safety light curtains are general purpose presence

More information

llen-bradley 194R-HM4-NFPA3

llen-bradley 194R-HM4-NFPA3 Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

We are your competent partner for cable routing

We are your competent partner for cable routing A Phoenix Mecano Company We are your competent partner for cable routing...ensuring your production processes don't get left hanging. BLOCAN Cable Channel System BLOCAN Cable Channel System Channel functionality

More information

Instructions for WiP Relay Block Kit

Instructions for WiP Relay Block Kit Instructions for WiP Relay Block Kit So you re working on a larger-than-normal electrical project? That s what this relay kit is offered for (it s also for use with the regular project that you may add

More information