SECTION CLOSED CIRCUIT TELEVISION (CCTV) SYSTEM
|
|
- Stewart Turner
- 5 years ago
- Views:
Transcription
1 SECTION CLOSED CIRCUIT TELEVISION (CCTV) SYSTEM Part 1 - GENERAL 1.01 SECTION INCLUDES A. This section describes the detailed technical requirements for the closed circuit television (CCTV) system to be designed, installed and tested under this contract. The CCTV system shall be designed to provide visual surveillance of designated areas at elevator entrances, interior of elevator cabs and both landings of escalators as defined in Metro Design Criteria for safety and security of patrons. This system shall provide monitoring capability for above specified areas and shall be compatible with the existing equipment at the Rail Operations Control (ROC). B. Contractor shall design, install and test the CCTV system and the associated networking equipment necessary to transmit video to the ROC via the cable transmission system (CTS) network. Metro will furnish CCTV equipments RELATED SECTIONS A. Section : Submittal Procedures B. Section : Project Quality Program Requirements - Design/Build 1.03 REFERENCES A. Design and operation of the CCTV system shall conform to the following reference codes, regulations, and standards as applicable: 1. American Public Transportation Association (APTA) a. APTA IT-CCTV-RP Recommended Practice, Selection of Cameras, Digital Recording Systems, Digital High-Speed Networks and Trainlines for Use in Transit-Related CCTV Systems. b. APTA SS-SIS-RP Technical Recommended Practice for Cameras Coverage and Field of View Criteria for Passenger Facilities. c. APTA-RT-S-SC Standard for Closed Circuit Television (CCTV) Inspection, Testing and Maintenance. Closed Circuit Television (CCTV) System
2 d. Security program considerations for Public Transit APTA SS-SIS-S , March 2013 e. Physical security for Public Transit APTA SS-SIS-RP-013-B, March Electronic Industries Association (EIAA) a. Bulletin #1 CCTV Definitions b. EIA-310D 19-inch Rack Standard c. EIA-568-A Commercial Building Telecommunications Cabling Standard d. EIA-632 Electronics Industrial Alliance (EIA) Standard: Processes for Engineer a System. e. EIA-649 Standard for Configuration Management f. EIA-836 Configuration Management Data Exchange and Interoperability 3. Industry Foundation Classes Standard (IFC) 4. Institute of Electrical and Electronics Engineers (IEEE) a. IEEE Ethernet (CSMA/CD) b. IEEE 1473 Communications Protocol Aboard Passenger Trains c. IEE 1220 Application and Management of the Systems Engineering Process 5. International Build Code (IBC) 6. International Organization for Standardization (ISO) a. ISO/IEC/JTC1/SC29 WG11 Coding of Moving Pictures and Audio 7. Manufacturing Method (MM) a. MM-33A Process Control Specification for Paint Application Closed Circuit Television (CCTV) System
3 b. MM-42 Process Control Specification of Chromate Conversion Coating 8. National Fire Protection Association (NFPA) a. NFPA 70 National Electric Code 9. National Electrical Manufacturers Association (NEMA) a. NEMA 3R Standards for Enclosure, Box & Cabinet Rating and Definition 10. California Occupational Safety and Health Standard (Cal/OSHA) 11. National Fire Protection Association (NFPA) a. NFPA 70 National Electric Code (NEC) 12. Underwriters Laboratories (UL) a. UL 2044 Standard for Commercial Closed Circuit Television Equipment. b. UL 2391 Equipment with Remote Feeding Telecommunication circuits Intend for Backwards Compatibility in Legacy Telecommunication Equipment c. UL 3044 Standards for Surveillance Closed Circuit Television Equipment 1.04 QUALITY ASSURANCE A. Comply with Project Quality Program Requirements (see 1.02 above). B. Manufacturer and Applicator/Installer Qualifications: 1. Manufacturer s Qualifications: Minimum of 5 years experience in manufacturing of specified materials/products, with record of successful in-service performance. 2. Applicator/Installer Qualifications: Engage applicator/installer with minimum 5 years experience in installation of materials/products similar in material, design, and to extent indicated for this Project. a. Installer Certification: Obtain written certification from manufacturer, certifying that installer is approved by, licensed, or certified by manufacturer for installation of specified materials/products or systems. Closed Circuit Television (CCTV) System
4 b. Provide list of minimum 5 projects similar in nature and size to that of this Project, where specified materials/products have been successfully installed/used. C. The Contractor shall perform the following: 1. Material qualification testing and certification for acceptance of materials, components and assemblies. 2. Job control testing of in-progress Work being performed in shops, factories and onsite. 3. On-site inspection of specified Work elements SUBMITTALS A. Refer to Section Submittal Procedures, for submittal requirements and procedures. B. Action Submittals 1. Floor plans showing locations of all devices. 2. Submit detailed hardware interface schematics and installation details. 3. Provide IP (Internet Protocol) addressing of all IP camera equipment. 4. Submit power cable voltage and fiber optic signal loss calculations to confirm proper device operation at designed cable lengths. 5. Mounting and installation details for cameras, pedestals and enclosures. 6. Submit termination and interconnection diagrams for all cable to each component furnished and installed under this Contract. 7. Submit manufacturer s technical product data for all devices furnished with certificates of compliance, dimensions, capacities, performance, electrical characteristics and start-up instructions. 8. Submit detailed installation work plans and procedures. 9. Submit detailed test plans and procedures for the following: a. Local field acceptance tests (LFAT) b. Systemwide field acceptance tests (SFAT) 10. Submit test records. C. Informational Submittals 1. Calculations and Certifications a. Calculations as listed above. Closed Circuit Television (CCTV) System
5 b. ISO certifications for all proposed D. Maintenance Material Submittals 1. As-Built Documentation a. Shop Drawings with the following information: 1) Plan diagrams showing location of all cameras and accessories. 2) Wiring diagrams. Clearly differentiate between portions of wiring that are factory-installed and portions to be field-installed. 3) Submit detailed information for all programmable equipment together with the associated passwords and access codes. b. Product Data: Submit approved manufacturer s technical product data. c. Submit manufacturer s operating and maintenance instructions for the complete system DEFINITIONS (Not Used) PART 2 - PRODUCTS 2.01 CONTRACT FURNISHED MATERIALS - GENERAL DESIGN REQUIREMENTS A. Functional Requirements 1. The system shall be designed for everyday safety and security requirements as well as anticrime and antiterrorist applications requiring the identification of unknown people and objects depicted within images. 2. The system shall provide monitoring capability and video recording of all cameras at the ROC. B. Elevators and Escalators 1. Dedicated fixed cameras shall be installed in the elevator cab that give full coverage and field of view of the cab interior and elevator entrance. The cameras within in the elevator cabs shall be corner mounted, grip free and vandal proof. 2. Camera should cover elevator cab with door opening on one side of the cab. For each elevator cab with doors on opposite sides of the cab, two cameras shall be used. 3. Dedicated Pan/Tilt/Zoom cameras shall be used that monitor elevator entrance areas from the outside of the elevator on bridge deck area and street level. 4. Dedicated Pan/Tilt/Zoom cameras shall be used that monitor each escalator at each landing (Top & Bottom). C. Design Criteria Closed Circuit Television (CCTV) System
6 1. The CCTV system shall be an IP-based system. 2. The CCTV picture characteristics shall be as follows: a. National Television System Committee (NTSC) color format 3. The CCTV system shall be capable of supporting the following video resolutions and shall be user-adjustable at the ROC console: a. Up to 30 fps (frame per second, user selectable 5, 15 or 30) at Common Intermediate Format (CIF) (360x240) b. Up to 30 fps (user selectable 5, 15 or 30) at 2CIF (720x 240 or 640x480) c. Up to 30 fps (user selectable 5, 15 or 30) at 4CIF (720x576) d. Minimum monitor resolution shall be 720 lines. 4. The camera shall provide a usable video signal (as defined below) over the entire specified range with a scene illumination as low as 1.0 foot-candle. The camera shall detect and render 10 shades of gray from the EIA (Electronic Industries Alliance) TV resolution chart with 5 fc (foot candle) illumination. 5. System shall be designed to provide a resolution upto 30 fps at 4 CIF from all cameras. 6. System shall be IP based and use the MPEG 4 protocol for transmission on the dedicated CCTV network. 7. Minimum ambient illumination shall be one fc when emergency lighting is activated. 8. The signal-to-noise ratio over the entire system length shall be no less than 44 db (for analog portion of the system, if used). 9. CCTV systems shall be configured in a hub-and-spoke arrangement, with local recording being undertaken and compressed images then being transmitted back to the ROC via a CTS or possibly wireless network. 10. Camera Identification a. A discrete camera ID consisting of a minimum of sixteen alphanumeric digits in ASCII-II code shall be superimposed on each camera video to identify the camera location. 11. Video Recording System a. All CCTV camera signals shall record video images in real time. Local network video server equipped with video storage hardware shall be able to store at least 30 days at 4 CIF. The recorded video images shall be capable of being retrieved and controlled by the ROC control console. New network video recorder shall be installed in station TC&C ROOM. Closed Circuit Television (CCTV) System
7 b. The CCTV system shall be capable of applying time and date stamps on each recording D. Operation: Continuous Duty 1. Digital Signatures E. Interface a. In order to digitally sign a file, all data/video files, which are to be protected, shall be passed through a hashing function. The hashing function shall produce a large checksum value for the file, which shall then be encrypted using the private key. The two hashing functions most recognized by and acceptable to Metro, which may be used for digital signature technologies, are MD5 and SHA-1. Contractor may propose equivalents for approval. b. Watermarks shall not be used for traceability of video evidence. The CCTV system shall be interfaced with ETEL and LTEL such that activation of ETEL or LTEL within viewing distance of a CCTV camera shall cause the video scene from that camera to be automatically displayed at the ROC on the console (event) monitor (camera call-up). If several calls are originated, the images shall be rotated on the console (event) monitor. The image shall be maintained until the ETEL or LTEL call(s) is terminated. After that the event monitor should display the last camera image prior to call-up event. F. Alarms 1. CCTV individual alarms shall be transmitted to supervisory control and data acquisition (SCADA) console in the ROC. 2. The alarms, at a minimum, shall include: a. Power failure b. CCTV communications equipment failure (transmission equipment) c. CCTV cable failure d. Video loss MAJOR COMPONENTS A. IP Cameras 1. Camera equipment furnished by Metro have the following features and meet the technical requirements listed herein: a. All camera equipment are IP-based and interchangeable between locations. b. Input Voltage: 24 VAC c. Produce a picture with no geometric distortion. Closed Circuit Television (CCTV) System
8 2. PTZ commands shall be non-proprietary and conform to industry standards. 3. PTZ cameras shall have the following additional features: a. Pan movement: -3 ~ 90 b. Tilt movement: 0 horizontal to 90 down 4. Power over Ethernet shall be used for all cameras in the project. B. Camera Enclosures 1. The Contractor shall provide an enclosure and mounting hardware required to install camera. 2. Enclosures shall run on 24 VAC power. 3. Enclosures shall meet NEMA 3R standards or better. 4. Window material shall be scratch-resistant. 5. Enclosures shall be installed with sunshields in areas where they are exposed to direct sunlight that could distort camera images. 6. Enclosures shall have lockable latches, capable of being padlocked for security. Any exterior fasteners shall be tamper-resistant. 7. Enclosures shall have a minimum of two sealable glands on the bottom of the enclosure for cable entry. All wiring shall be terminated neatly on wiring blocks/terminals within the enclosure. 8. All holes in camera enclosures shall be sealed to prevent debris from entering. Camera equipment shall be electrically isolated from bridge structure grounding systems. 9. Any deviation from the approved configuration of camera placement shall be subject to Metro approval. C. Camera Mounting Kits 1. Camera mounting kits shall be used to support the loads of camera and enclosure along with the wind load. All parts shall be protected from corrosion. 2. For pole-mounted cameras, adapters shall be provided for placing standard wallmount units on camera-equipped poles. D. Local Area Networking (LAN) Equipment Ethernet switch shall be required to connect all cameras at bridge structure locally, aggregate video and transmit video to a CTS node that transports video to the ROC CCTV console via the CTS network. Ethernet switches shall have following features: 1. Ethernet switches shall support IEEE (10BaseT), IEEE 802.3u (100BaseTX, FX) standards. Closed Circuit Television (CCTV) System
9 2. Ethernet switches shall have sufficient quantities of copper, RJ-45, 10/100 ports sufficient to connect all cameras, plus 50 percent spare. Where an Ethernet switch is more than 300 feet from the CTS node it connects to, two or more 100BaseFX fiber ports supporting transmission over multimode or single-mode fiber-optic cabling or media converter shall be provided to uplink video to the CTS as indicated. All fiber ports shall be duplex. 3. Ethernet switches shall have the following indicators - Port status LEDs, system status LEDs, power status LEDs. 4. Ethernet switches shall be capable of local management and shall be remotely manageable by a telnet connection and a single simple network management protocol (SNMP)-based manager application. 5. Ethernet switch shall be mounted properly in a wall mount enclosure. E. PoE Ethernet Extender 1. Category 6 cable extenders shall be used when the cable length between the nearest switch and the camera is greater than 300 ft, or when the signal becomes degraded due to cable length. 2. Ethernet extenders shall be paired identically to ensure compatibility. 3. Units shall have a line interface and a 10/100BaseT Ethernet RJ-45 equipment interface. 4. Remote extenders used at cameras shall be non-powered. F. PoE Media Converter Media converters shall be used to convert optical input signals from the remote CCTV cameras to electrical signal output to the Ethernet switch. 1. LAN media converters shall convert the 10/100 Base-T/TX ports of Ethernet switching modules to 100 Base-FX for transmission over fiber optic media. The Contractor shall furnish, install, and test these media converters. 2. Where installed with other modular media converter chassis, modules shall be added to that chasses rather than installing stand-alone media converters. 3. The converters shall comply with the following requirements: a. 10/100 Base-T/TX to 100 Base- FX converter b. Interfaces: 100 Base-TX (RJ-45), 100 Base-FX (SC) optical c. Protocol Compatibility: IEEE 802u 100 Base-TX and 100 Base-FX Standards d. Operating Distance: 328feet for 100Base-TX, 1.3 mile for 100 Base-FX MM, 9.4 miles for 100 Base-FX SM e. Data Flow: Half or full duplex support Closed Circuit Television (CCTV) System
10 f. LEDs: Power, link, transmit, receive g. Fiber Requirements: Multimode, and single-mode fiber cabling with SC connectors h. Input Power Requirement: 120 VAC G. Power Supplies - if Power over Ethernet (PoE) is not used VAC a. Both camera and enclosure shall be powered by a 24 VAC power supply. Input power shall be sourced from the newly installed uninterruptible power supply (UPS) in the bridge electrical room, 120V, 208 or 277 VAC) through a transformer. b. Each power supply output shall have a fuse sized adequately for all connected equipment, but no less than one (1) amp. c. PTZ cameras shall have their own power supply. d. Power supply shall have integrated surge suppression on the AC voltage input. e. Power supplies shall be UL listed. 2. Individual Camera Power Transformer a. Contractor shall provide transformers for 24 VAC power requirements of camera and enclosure where conduits cannot connect camera location to centralized camera power supply. b. Single-phase primary input voltage will be 120/208/277 VAC, depending on the available power at the camera location. The output voltage will be 24 VAC to the camera and enclosure. c. Transformer shall be housed in an appropriately environmentally protected enclosure (minimum acceptable NEMA 3R). H. Digital Video Recording 1. Network Video Recorder (NVR) shall be provided for video data recording. Recorded image resolution can be up to 30 fps (user selectable 5, 15 or 30) at 4CIF for 30 days. I. Local Network Video Server (NVS) 1. Contractor shall provide the network video server for local and remote access, playback, and evaluate the video surveillance data stored in the NVS. 2. Storage capacity shall be as specified. PART 3 - EXECUTION Closed Circuit Television (CCTV) System
11 3.01 INSTALLATION A. General 1. Installations shall comply with NFPA, IBC, IFC, NEC and equipment manufacturers requirements and procedures. 2. Field adjustments shall be made as required to provide or improve the field of view of the area to be monitored. Final alignment shall be the responsibility of the contractor, and any costs related to changing lenses to obtain the desired field of view shall be included in the original bid price. 3. All equipment shall be grounded in accordance with the recommendations of the manufacturers. B. Field Installation 1. CCTV rack shall be installed and securely bolted to the floor in the existing TC&C room as required. 2. Cabling shall be secured to racks and cable trays using approved cable management equipment to avoid any pinching or microbends. Fiber optic cables shall be secured only with Velcro-type cable ties. 3. All power, control, and communications cabling shall be concealed from public view inside conduits or other defined cableways. 4. Fiber boots shall be installed on fiber jumper connectors at connection points requiring a 90-degree or greater bend within six inches of the connector. 5. Conduits for the CCTV system consist of two conduits in parallel, both serving each camera location. All conduits shall be GRS, minimum one inch TESTING A. Testing shall be conducted to verify picture-to-noise ratios for all video signals. Resolution, low-light level performance and auto-iris operation shall be tested for each camera make/model employed in the system MANUAL A. Operations and maintenance manuals shall be provided for all active equipment and for the overall system. END OF SECTION Closed Circuit Television (CCTV) System
SECTION 686 VIDEO DECODER DESCRIPTION
686 SECTION 686 VIDEO DECODER DESCRIPTION 686.01.01 GENERAL A. This specification describes the functional, performance, environmental, submittal, documentation, and warranty requirements, as well as the
More information1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment
1993 Specifications CSJ 0922-33-042, etc. SPECIAL SPECIFICATION ITEM 8549 CCTV Central Equipment 1. Description. This Item shall govern for the furnishing and installation of closed circuit television
More informationB. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.
VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems
More informationSECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION
683 SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION 683.01.01 GENERAL A. The Contractor shall furnish the designated quantity of Video Optical Transceiver (VOTR) pairs
More informationSPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel
1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed
More informationSPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment
1993 Specifications CSJ 0027-12-086, etc. SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of color
More informationSPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment
1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video
More informationSPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment
2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment
More information1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT
1995 Metric CSJ 0508-01-258 SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1.0 Description This Item shall govern for the furnishing and installation of color Single
More informationSPECIAL SPECIFICATION 8276 CLOSED CIRCUIT TELEVISION SYSTEM
2004 Specifications CSJ 0196-07-027 SPECIAL SPECIFICATION 8276 CLOSED CIRCUIT TELEVISION SYSTEM 1. Description. Supplier s scope as defined by this specification shall include the furnishing of all engineering,
More informationHONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA
Section 00000 SECURITY ACCESS AND SURVEILLANCE HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA PART 1 GENERAL 1.01 SUMMARY The intent of this document is to specify the minimum criteria for the
More informationSalient Systems June, N Mopac Expy, Bldg 3, Ste 700 Austin, Texas FAX
Salient Systems June, 2014 10801 N Mopac Expy, Bldg 3, Ste 700 Austin, Texas 78759 512-617-4800 512-617-4801 FAX www.salientsys.com Product Guide Specification Specifier Notes: This product guide specification
More informationBILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School
BILOXI PUBLIC SCHOOL DISTRICT Biloxi Junior High School Request for Proposals E-Rate 2014-2015 - Internal Connections Submit Proposals To: Purchasing Department Attn: Traci Barnett 160 St. Peter Street
More informationGigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT
COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationSPECIAL SPECIFICATION 6713 Ethernet Video Decoder (MPEG-4)
2004 Specifications CSJ 0016-04-103, etc. SPECIAL SPECIFICATION 6713 Ethernet Video Decoder (MPEG-4) 1. Description. Furnish, install, and make fully operational with the TransGuide or Combined Transportation,
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationSPECIAL SPECIFICATION 6700 CCTV Field Equipment
2004 Specifications CSJ 0017-10-240 SPECIAL SPECIFICATION 6700 CCTV Field Equipment 1. Description. Provide, install, and make fully operational with the TransGuide system Closed Circuit Television (CCTV)
More informationSPECIAL SPECIFICATION 1726 CCTV Field Equipment
1993 Specifications CSJ 0018-06-021& 0922-11-017 SPECIAL SPECIFICATION 1726 CCTV Field Equipment 1. Description. This Item shall govern for the furnishing and installation of closed circuit television
More informationSPECIAL SPECIFICATION 6735 Video Optical Transceiver
2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6735 Video Optical Transceiver 1. Description. This Item governs the furnishing and installation of Video optical transceiver (VOTR) in field location(s)
More informationQuick Operation Guide of LTN7700/7600 Series NVR
Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable
More informationSPECIAL SPECIFICATION 1118 Dual OC-3 ATM MPEG-2 Encoder
1993 Specifications CSJ 0521-04-190 SPECIAL SPECIFICATION 1118 Dual OC-3 ATM MPEG-2 Encoder 1. Description. Furnish, install, and make fully operational an Asynchronous Transfer Mode (ATM) Video Encoder
More informationSECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS
SECTION 27 51 23 SPEC WRITER NOTES: 1. Use this section only for NCA projects. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Contact Department of Veterans
More information100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual
100Base-FX Multi-mode to 100Base-FX Single Mode Converter NXF-708 Series User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationREQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus
REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus PART 1: GENERAL REQUIREMENTS A. Contractor Work 1. Provide and install (except as noted in this document), cable,
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SURVEILLANCE SYSTEM, REMOTE SITE. ITS:CLC 1 of 7 APPR:LWB:DBP: FHWA:APPR:
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SURVEILLANCE SYSTEM, REMOTE SITE ITS:CLC 1 of 7 APPR:LWB:DBP:07-15-16 FHWA:APPR:07-29-16 a. Description. This work consists of furnishing, installing,
More informationPurchasing Department Finance Group INVITATION TO BID
Purchasing Department Finance Group July 3, 2013 INVITATION TO BID The City of Norwalk is soliciting bids for the Building Management Department for Network Video Recording (NVR) Equipment for the existing
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD, applicable TC -, and CEHNC Design Guide 0-- (Standard is single UTOs and Double UTOs) B. Roads-Service, Lanes Adequate access is provided to the and AAR D. Testing Results-provided
More informationAnalog HD video over fiber converters for smart HD CCTV
Our AHD Video over Fiber Converters can simultaneously transmit 1-16 channels AHD over one multimode or single-mode optical fiber. Electronic and optical adjustments are never required. LED indicators
More informationSalient Systems July, N. MoPac Expy. Building 3, Suite 700 Austin, TX FAX
Salient Systems July, 2016 10801 N. MoPac Expy. Building 3, Suite 700 Austin, TX 78759 512-617-4800 512-617-4801 FAX www.salientsys.com Product Guide Specification Specifier Notes: This product guide specification
More informationMICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features
Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX Description This Ethernet Switch Module has been designed with 4x10/100Base-TX ports and 1x100Base-FX fiber optic port for the interconnection
More informationINSTALLATION MANUAL FT-FOTR-1VDE-ST-S
INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package
More informationInstallation. SAPTF33xx-1xx in the Network. Standard Configuration
SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device
More informationColour Explosion Proof Video Camera USER MANUAL VID-C
Colour Explosion Proof Video Camera USER MANUAL VID-C Part Number: MAN-0036-00 Rev 4 Copyright 2002 Net Safety Monitoring Inc. Printed in Canada This manual is provided for informational purposes only.
More informationACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO
SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationCoastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents
PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2
More informationUNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE
UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and
More informationSPECIAL SPECIFICATION 6559 Telecommunication Cable
2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,
More informationSECTION TESTING, IDENTIFICATION AND ADMINISTRATION
PART 1 - GENERAL 1.1 SUMMARY SCOPE SECTION 25170 TESTING, IDENTIFICATION AND ADMINISTRATION 1. This section includes the minimum requirements for the testing, certification administration and identification
More informationCisco Video Surveillance 6400 IP Camera
Data Sheet Cisco Video Surveillance 6400 IP Camera Product Overview The Cisco Video Surveillance 6400 IP Camera is an outdoor, high-definition, full-functioned video endpoint with an integrated infrared
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002
STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 02 872.01 Description 872.02 Prequalification 872.03 Material Requirements
More informationA. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
ENDURA NET5308T VIDEO ENCODER TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1 28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2 28 23 00 VIDEO SURVEILLANCE LEVEL 3 28
More informationSPECIAL SPECIFICATION 8540 Telecommunication Cable
2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,
More informationSECTION COMMUNICATIONS HORIZONTAL CABLING
SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors including patch panels. 3. Cabling identification
More informationPrimex Wireless, Inc. July, Wells Street Lake Geneva, WI
Division 0 0 0 0 Primex Wireless, Inc. July, 00 Wells Street Lake Geneva, WI 00--0 www.primexwireless.com Product Guide Specification Specifier Note: This product specification is written according to
More informationMinimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)
PART 1: GENERAL 1.01 Telecommunications Engineer Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) B. Registered Communications Distribution Designer
More informationSPECIAL SPECIFICATION 1116 CCTV Field Equipment
1993 Specifications CSJ 0521-04-190 SPECIAL SPECIFICATION 1116 CCTV Field Equipment 1. Description. This Item shall govern for the furnishing and installation of Closed Circuit Television (CCTV) Field
More informationSPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment
2004 Specifications CSJ 0922-00-025, 0921-02-173 & 0921-06-208 SPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment 1. Description. Furnish and install closed circuit television (CCTV) central equipment
More informationSPECIAL SPECIFICATION 2344 TMC Support Equipment
2004 Specifications CSJ 0912-00-488 SPECIAL SPECIFICATION 2344 TMC Support Equipment 1. Description. Furnish Traffic Management Center (TMC) support equipment in the City of Missouri City TMC location
More informationADDENDUM NO. 1 FDVA-ITB B ITB TITLE: JENKINS AUDIO/VIDEO SECURITY SYSTEM ISSUE DATE: THURSDAY, JUNE 30, 2016
Glenn Sutphin Interim Executive Director State of Florida DEPARTMENT OF VETERANS AFFAIRS Division of Administration and Public Information 11351 Ulmerton Road, #311-K Largo, FL 33778-1630 Phone: (727)
More informationMAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide
MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK Model MX3257HD Description The rack-mountable MX3257HD fiber optic video multiplexer is ideal for transmitting 1 channel of video, 2 channels
More informationMIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project
1.1.0 GENERAL The purpose of this specification is to establish a requirement for the installation of a voice, video and data cable network. The cable (copper), wire, hardware, equipment racks, jumpers,
More informationCFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit
CFMFF1317-210 SC, 1300 nm multimode CFMFF1717-210 60 km (37.2 miles) CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit Transition Networks CFMFFxxxx-2xx series
More informationCalifornia Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationDS-7200HVI/HFI-SH Series DVR Quick Operation Guide
DS-7200HVI/HFI-SH Series DVR Quick Operation Guide UD.6L0202B0019A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is
More informationA. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete.
SPECIFICATIONS GPS Wireless Clock System Section 16730 TIME SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete. B.
More informationPre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017
Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library
More informationSECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.
SECTION 33 71 49.23 MEDIUM VOLTAGE CABLE INSTALLATION PART 1 GENERAL 1.1 SCOPE A. Work included in this Section: Medium Voltage Cable (4 kv and 12 kv) Installation and Termination. Removal and return of
More informationOperating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA
Operating Manual Automated Gear Apollo Design Technology, Inc. 4130 Fourier Drive Fort Wayne, IN 46818 USA PH: +01(260)497-9191 FX: +01(260)497-9192 www.apollodesign.net 11-25-09 5-6 POWERING UP THE RIGHT
More informationSECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA
SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA TABLE OF CONTENTS Section Title Page 5901 GENERAL... 2 5902 DESIGN CRITERIA... 2 5902.1 Codes and Standards... 2 5902.2 Signal
More informationDatasheet EC-750 Ex DOME Camera
Product: EC-750 Ex DOME Camera Description and highlights Explosion proof color TV camera with swivelling head and zoom Chemical, shock and vibration resistant Water- and dustproof IP68 Compact and light
More informationRequest for Quote E- Rate Eligible Services Scope of Work Network Infrastructure and Structured Cabling
Request for Quote E- Rate Eligible Services Scope of Work Network Infrastructure and Structured Cabling Due Date: Allowable Contract Date from Posted 470 The Clarkdale- Jerome School District is requesting
More informationCASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS
CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS Cass County, Michigan invites qualified vendors to submit proposals for the purchase, installation, and programming of a centralized
More informationA. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
ESPRIT SERIES POSITIONING SYSTEM TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1 28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2 28 23 00 VIDEO SURVEILLANCE LEVEL 3
More informationGAMING COMMISSION REGULATIONS ESTABLISHING MINIMUM STANDARDS FOR SECURITY AND SURVEILLANCE
GAMING COMMISSION REGULATIONS ESTABLISHING MINIMUM STANDARDS FOR SECURITY AND SURVEILLANCE Coyote Valley Gaming Commission Coyote Valley Band of Pomo Indians Chapter 5 MINIMUM STANDARDS FOR SECURITY AND
More informationA. All communications equipment rooms shall be installed in a neat and workmanlike manner.
SECTION 27 11 00 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationCisco DAXI. Features. Data Sheet. Cisco DAXI. Figure 1.
Cisco DAXI The Cisco DSAN Auxiliary Input Box (DAXI) is a compatible external product that converts up to four analog video channels to digital format for distribution via the Digital Service Access Node
More informationIndex Contents: 1000 Series Single Channel Multi Mode Fiber Optic Video Solutions Product Overview Product Configurations Product Specifications
Welcome Nitek is a Rolling Meadows, Illinois based manufacturing company with a primary focus on design, development and manufacturing of high performance, reliable CCTV video transmission systems. Nitek
More informationTelecommunciations Infrastructure Project September 20, A. Broadband radio frequency active and passive components
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Broadband radio frequency active and passive components B. Broadband optical active and passive components C. Coaxial cable and connectors D. Support and termination
More informationA. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
SPECTRA MINI SERIES DOME SYSTEM, NTSC/PAL TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION -- 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1 28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2 28 23 00 VIDEO SURVEILLANCE
More informationMarch 4 th, Addendum No. 1. Brooklyn College Systems Integrator Broadcast Television Equipment Project No: BY019/
Facilities Planning, Construction, and Management Office of Financial Management Procurement Services 555 West 57 th Street 11 th Floor New York, New York 10019 CUNY.Builds@mail.cuny.edu March 4 th, 2013
More informationSTRUCTURED CABLE SYSTEM (SCS)
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationGE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM
g GE Interlogix Fiber Options Instruction Manual S700V & S702V FIBER-OPTIC VIDEO TRANSMISSION SYSTEM Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment
More informationINSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras
INSTALLATION MANUAL FT-FOTR-8VD-ST-S 8-Channel Digital Duplex Baseband Transmitter and Receiver With Reverse Transmission for PTZ Cameras v1.0 4/5/11 1 PACKAGE CONTENTS This package contains: One each
More informationE3/DS3 Fibre Extender
User Manual E3/DS3 Fibre Extender Black Box Network Services 464 Basingstoke Road, Reading, Berkshire, RG2 0BG Tech: 0118 965 6000 www.blackbox.co.uk CONTENTS 1 Introduction 1 1.1 About the products 1
More informationDATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.
DATA/SPEC SHEET V920 KOLLECTOR - PRODUCT FORCE DESCRIPTION 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER Configured with ViconNet Video Management Software (VMS) Scalable from one to hundreds of recorders Support
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationRequest for Quote E- Rate Eligible Services Scope of Work - Wireless LAN and Cabling for Access Points
Request for Quote E- Rate Eligible Services Scope of Work - Wireless LAN and Cabling for Access Points Due Date: Allowable Contract Date from Posted 470 The Palo Verde Elementary School District is requesting
More informationDescription. Features MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2.
MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2 Description Features The Light LinkB B Series 2 Optical distribution node with two amplified RF ports (ODN2P) has been
More informationUSER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH
USER GUIDE AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH Electromagnetic Compatibility (EMC) This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
More informationNational Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.
National Park Service Photo Utah 400 Series 1 Digital Routing Switcher Utah Scientific has been involved in the design and manufacture of routing switchers for audio and video signals for over thirty years.
More informationInformation Technology Services DESIGN AND INSTALLATION STANDARDS
Requirements and Guidelines for: New Construction, Renovations, Upgrades, and Retrofits. Revised: June 5, 2015 VIU ITS Network Services 2 TABLE OF CONTENTS 0 GENERAL... 5 1 FIBER OPTIC CABLING... 5 1.1
More informationSpecial Specification 6293 Adaptive Traffic Signal Control System
Special Specification Adaptive Traffic Signal Control System 1. DESCRIPTION 2. MATERIALS Furnish, install, relocate, or remove adaptive traffic signal control (ATSC) system software and equipment at locations
More informationMS2540 Current Loop Receiver with RS485 Communication
MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:
More informationSpec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights
In-Building Wireless Networking System InterReach Fusion is the latest addition to ADC s portfolio of Distributed Antenna Systems. It offers the same superior performance as Unison in an easy-to-install,
More informationSECTION FIBER OPTIC STATION CABLES
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications shall include all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationCASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS
CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS Cass County, Michigan invites qualified vendors to submit proposals for the purchase, installation, and programming of: a door card
More informationFollow The Leader In Shielded Technology
1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated
More informationFLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems
FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems Item No. 1 Specifications Required Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor (cooled) systems SMC 3500 x 3 sets Required
More informationTelecommunication Infrastructure Project September 20, 2002
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Category rated UTP systems shall be provided and tested in accordance with the performance level established in Specification
More informationAUTOMATIC VIDEO LOSS A/B SWITCH
CG-X AUTOMATIC VIDEO LOSS A/B SWITCH INSTRUCTION BOOK IB647502 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 3 HOW TO CABLE THE CG-X 3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE AND MAINTENANCE
More informationSPECIAL SPECIFICATION 6734 CCTV Central Equipment
1995 Metric CSJ 0038-01-033, Etc. SPECIAL SPECIFICATION 6734 CCTV Central Equipment 1. Description. This Item shall govern for the furnishing and installation of Closed Circuit Television (CCTV) central
More informationPublic Works Division Lighting District Fiber Optic Specifications April 2009
Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks
More informationWATCHMASTER IP THERMAL SURVEILLANCE SYSTEMS
WATCHMASTER IP THERMAL SURVEILLANCE SYSTEMS Furnishing Systems Integrators with a competitive edge by providing 24/7 affordable thermal solutions that outperform conventional surveillance technologies,
More information1995 METRIC CSJ SPECIAL SPECIFICATION ITEM 6573 CCTV CENTRAL EQUIPMENT
1995 METRIC CSJ 0196-03-209 SPECIAL SPECIFICATION ITEM 6573 CCTV CENTRAL EQUIPMENT 1.0 DESCRIPTION. THIS ITEM SHALL GOVERN FOR THE FURNISHING AND INSTALLATION OF CLOSED CIRCUIT TELEVISION (CCTV) CENTRAL
More informationDigital Video Recorder
Digital Video Recorder Quick Operation Guide UD.6L0202B0067A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable
More informationDINOX&Digital&Video&Recorder&
DINOX&Digital&Video&Recorder& & & & & & & & & & &&&Quick&Operation&Guide& UD.7L0X02B1228B01& Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact
More informationPSI-MOS-RS232/FO 850 E Serial to Fiber Converter
PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to
More informationTruck router (3Gbps/HD/SD/ASI)
NVISION 8288 Truck router (3Gbps/HD/SD/ASI) The ultra-compact NVISION 8288 truck video routers are the world s smallest large routers with full broadcast quality, resilience and advanced control systems.
More informationFibre Optic Modem ODW-622
Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.
More information