STED, on the SP5WLL. Wellcome on the STED Tutorial
|
|
- Gerard Fisher
- 5 years ago
- Views:
Transcription
1 STED, on the SP5WLL. Wellcome on the STED Tutorial Before using the Sp5 WLL STED microscope, you will need to put down your name on the reservation system = Version
2 System start Up. (Page 3-8) Laser switch and calibration (page 11-13) Sted configuration(page 14-17) System shut down. (page 18-22) 2
3 System Start up (step 1) On the STED Tower, Switch ON the button 3
4 System Start up (step 2) The SHG led turns green for 3sec, then it s turns orange for 3 minutes, then it s turns green again after 1 minutes. 4
5 System Start up (step 3) Turn the key from the depletion laser 592-nm to vertical position. The SHG led turns green. 5
6 System Start up (step 4) Push the PC/Microscope button Push the Scanner Power button. Push the Laser Power button (White laser is on ). Turn the Key on the right position (Argon laser is on ). 6
7 System Start up (step 5) Turn on the XCite Light. 7
8 System Start up (step 6) When the computer is on Introduce your Username Introduce your Password Introduce your login Start the LASAF software. Under Configuration select Machine STED. Do OK 8
9 Choosing the objective Under Acquire and Acquisition Choose and select your objective in the list. To acquire a STED image you need to use the HCX PL APO CS 100x 1.40 OIL 9
10 Choosing the Filter You need to introduice a Notch filter to block the laser 592nm Select Analyzer Filter Deselect Auto Select Select NF STED filter 10
11 Laser Switch 1 Under Configuration select 2times the 592 depletion laser Be sure the Laser Enabled led appears white (on the STED tower). 11
12 Laser Switch 2 Under Hardware Configuration and Laser select the WLL and Argon Laser. Increase the power of the 592 Depletion laser to 75% ( minimum) 100%. Increase the wll laser to 70% ( good value = the laser is very stable). Increase the Argon laser to 30%. 12
13 Laser calibration/alignement Every time that you want to use the STED, you need to allign the 592 laser vs WLL laser. Go to the STED Setting dialogue and press the Align Beams fonction. Wait until the calibration is finish. Press OK. 13
14 Conventional configuration By using the depletion laser 592nm, the samples can be bleach very quickly, so first scan the sample in standard Confocal mode to find the focus and prepare the STED configuration close to work. Set the WLL laser line that you need to use (10 to 30 %). Select the Hyd 2 detector and set it, to 100%. Set the Hyd bandwidth. Its start must be 10nm bigger than the WLL excitation line used and its end must not exceed 582nm. Use a format like 512x512 or 1024x1024. Use a scan speed like 400HRZ. Use a zoom factor from 4 to 6. 14
15 STED configuration ( step1) Select the STED mode. Set the WLL laser line that you need to use ( for ex. 488nm at 30 % to 50% transmission ). Select the Hyd 2 detector and set it to 100%. Introduce to the Hyd a bandwidth that is 10nm fahter to the WLL line that you set, and maximum 10nm lower than the wavelength of the laser depletion ( +/-582nm). Open the Gate Setting; set the Wll value which is equal to the value you use to excite the fluorochrome (for ex 488nm) Set the Gate Start from 0,5 to 2,5 1,5 a compromise Set the Gate End to 6,5 15
16 STED configuration (step2) Use a format like 1024x1024 to 2048x2048. Use a scan speed like 200 to 400HRZ. Use a zoom factor from 4 to 6. Very important,control that the pixel size is 20nm or less. Use 3-4 Accu in frame mode. Use 0-4 average in line mode. Ex. if you use 200 HRZ, use 2 3 accu without average. If you use 400 HRZ use 2-3 accu with 2-4 average. 16
17 STED configuration (step3) Select Switch Conventionel Laser. Select the STED. Set the Depletion 592nm laser line at 100% You can use less than 100%, but you may lost some resolution, and win some intesity. Use Start and not live to acquire the image. 17
18 System Shut Down (step 1) Before you exit from the software.please clean the objective. Turn off the 3 lasers 18
19 System Shut Down (step 2) Exit from the LASAF software. Go to Start and shut down the computer. 19
20 System Shut Down (step 3) Turn on the XCite Light. 20
21 System Shut Down (step 4) Turn the Key on the left position (Argon laser is off ). Turn off the Laser Power button (White laser is off ). Turn off the Scanner Power button Turn off the PC/Microscope button 21
22 System Shut Down (step 5) On the STED Tower, turn the Key vertical position Switch off the button 22
Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope
Indiana Center for Biological Microscopy Zeiss LSM-510 510-UV Confocal Microscope Microscope and the Attached Accessories Transmission Detector Halogen Lamp House Condenser Eyepiece Stage Scanning and
More informationLeica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life
Leica TCS CARS Live Molecular Profiling Technical Documentation Living up to Life Microscopes Inverted Leica DMI6000 CS Microscope anti-vibration table Specification Vibration insulation Passive Z-drive
More informationPlease feel free to download the Demo application software from analogarts.com to help you follow this seminar.
Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a
More informationQuick Start Guide. Multidimensional Imaging
Quick Start Guide Multidimensional Imaging Printed 11/2012 Multidimensional Imaging Content Quick Start Guide Content 1 Introduction 4 2 Set up multi-channel experiments 5 2.1 Set up a new experiment
More informationVasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer
Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer solvents) Updated November 14, 2017 Instrument instructions can be found at: http://academic.bowdoin.edu/chemistry/resources/instructions.shtml
More informationStandard Operating Procedure of nanoir2-s
Standard Operating Procedure of nanoir2-s The Anasys nanoir2 system is the AFM-based nanoscale infrared (IR) spectrometer, which has a patented technique based on photothermal induced resonance (PTIR),
More informationConfocal Application Notes Vol. 2 May 2004
The Sequential Scan Tool In Sequential Scan mode, images will be recorded in a sequential order instead of acquiring them simultaneously in different channels. Each sequence can be recorded using an individual
More informationPreparing for remote data collection at NE-CAT
Preparing for remote data collection at NE-CAT Important Note: The beamtime and remote login privileges are intended just for you and your group. You are not allowed to share these with any other person
More informationStandard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology
Standard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology Before starting with the CytoFLEX S Flow Cytometer: 1. A new user needs to get an introduction to the flow cytometer
More informationCONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes
CONFOCAL MICROSCOPE Instrument Details: Make: Zeiss Modal: LSM 700 Specifications: Microscopes Stands: Upright: Axio Imager.Z1m, M1m and Axio Scope mot for LSM Inverted: Axio Observer.Z1m SP (side port)
More informationUpdate Records. Scanning Update Records
Scanning Update Records This document provides a step-by-step tutorial on how to scan Update Records and verify the imported information. 1) From the Tools Menu, select Scanning Wizard. 2) Select Using
More informationRelease Notes for LAS AF version 1.8.0
October 1 st, 2007 Release Notes for LAS AF version 1.8.0 1. General Information A new structure of the online help is being implemented. The focus is on the description of the dialogs of the LAS AF. Configuration
More informationWhat s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven
What s New in Raven 1.3 16 May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven 1.2.1. Extensible multi-channel audio input device support
More information2.1. Log on to the TUMI system (you cannot proceed further until this is done).
FEI DB235 ex-situ lift out TEM sample preparation procedure Nicholas G Rudawski ngr@ufledu (805) 252-4916 Last updated: 06/19/15 DISCLAIMER: this procedure describes one specific method for preparing ex-situ
More informationNONDESTRUCTIVE INSPECTION OF A COMPOSITE MATERIAL SAMPLE USING A LASER ULTRASONICS SYSTEM WITH A BEAM HOMOGENIZER
NONDESTRUCTIVE INSPECTION OF A COMPOSITE MATERIAL SAMPLE USING A LASER ULTRASONICS SYSTEM WITH A BEAM HOMOGENIZER J. M. S. Sakamoto 1, 4, A. Baba 2, B. R. Tittmann 3, J. Mulry 3, M. Kropf, 3 and G. M.
More informationBuilding Your Own 2-Photon Microscope: Challenges, Advantages and Limitations
Building Your Own 2-Photon Microscope: Challenges, Advantages and Limitations Roberto Weigert, Ph.D. Chief, Intracellular Membrane Trafficking Section Oral and Pharngeal Cancer Branch NIDCR-NIH Building
More informationTransitHound Cellphone Detector User Manual Version 1.3
TransitHound Cellphone Detector User Manual Version 1.3 RF3 RF2 Table of Contents Introduction...3 PC Requirements...3 Unit Description...3 Electrical Interfaces...4 Interface Cable...5 USB to Serial Interface
More informationMeasurement of Microdisplays at NPL
Conference on Microdisplays Measurement of Microdisplays at NPL Christine Wall, Dr Julie Taylor, Colin Campbell 14 th Sept 2001 Overview Displays measurement at NPL Why measure microdisplays? Measurement
More informationThe PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.
PHI VersaProbe Scanning XPS System I. Overview The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction. PHI Summitt
More informationMosaic. Mosaic Real Time Parallel Illumination of Multiple Regions. Features and Benefits. DMD Technology. Specifications Summary
Active Illumination Features and Benefits Unlimited flexibility in shape, size and complexity of illumination mask Simultaneous illumination of multiple regions of interest Precise illumination of areas
More informationAFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)
AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode) 1. Log into the Log Usage system on the SMIF web site 2. Open Nanoscope 6.14r1 software by double clicking on the Nanoscope 6.14r1 desktop
More informationDurham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications
Durham Magneto Optics Ltd NanoMOKE 3 Wafer Mapper Specifications Overview The NanoMOKE 3 Wafer Mapper is an ultrahigh sensitivity Kerr effect magnetometer specially configured for measuring magnetic hysteresis
More informationSEM- EDS Instruction Manual
SEM- EDS Instruction Manual Double-click on the Spirit icon ( ) on the desktop to start the software program. I. X-ray Functions Access the basic X-ray acquisition, display and analysis functions through
More informationDigital SWIR Scanning Laser Doppler Vibrometer
Digital SWIR Scanning Laser Doppler Vibrometer Scan-Series OptoMET Scanning SWIR Laser Doppler Vibrometer (SLDV) is used for non-contact measurement, visualization and analysis of structural vibrations.
More informationLSR II Users Guide Stanford Shared FACS Facility
LSR II Users Guide Stanford Shared FACS Facility PPE must be worn at all times in our BSL-2 environment *Lab coat, gloves, and closed toed shoes are mandatory; respirator and goggles are available* An
More informationSPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University
SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University Introduction: Scanning Probe Microscopy (SPM) is a general term referring to surface characterization techniques that utilize
More informationAnalysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised
Analysis and sorting of cells with FACSAria II flow cytometer 10.6.2010 Tiina Pessa-Morikawa / Revised 16-03-17 This instruction refers to the operating manual (FAUG, i.e. FACSAria II Users Guide and page
More informationRaptor University. Raptor System Kiosk Training. Instructor: RAPTOR TECHNOLOGIES, LLC
Raptor University Raptor System Kiosk Training Instructor: RAPTOR TECHNOLOGIES, LLC Kiosks provide self service sign in and sign out functionality for visitors, contractors, students, staff and volunteers.
More informationNOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.
Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only
More informationTT AFM LongBeach Procedures and Protocols V2.1
TT AFM LongBeach Procedures and Protocols V2.1 1. Startup Procedure 1. Turn on PC: Allow to boot to Windows. Turn on monitor. Password is afm 2. Turn on second PC that controls the video camera. 3. Turn
More informationDigital SWIR Scanning Laser Doppler Vibrometer
Digital SWIR Scanning Laser Doppler Vibrometer Scan-Series OptoMET Scanning SWIR Laser Doppler Vibrometer (SLDV) is used for non-contact measurement, visualization and analysis of structural vibrations.
More information1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.
TENDER SPECIFICATIONS FOR THE SUPPLY, DELIVERY, INSTALLATION AND COMMISSIONING OF ONE UNIT OF VARIABLE PRESSURE ENVIRONMENTAL SCANNING ELECTRON MICROSCOPE (SEM) CUM ENERGY DISPERSIVE SPECTROSCOPY (EDS)
More informationUser Guide. Best Seat Help Desk 24 hours a day/7 days a week
Android TM App User Guide Best Seat Help Desk 24 hours a day/7 days a week 1-800-455-5958 ManageMyTVs Application 1. To use the ManageMyTVs application, select the ManageMyTVs icon from the screen. The
More informationRobarts Research Institute at the Western University London, Ontario, Canada
About the facility: Robarts Research Institute at the Western University London, Ontario, Canada The London Regional Cell and In Vitro Molecular Imaging Facility is located within the Robarts Research
More informationScreen investigations for low energetic electron beams at PITZ
1 Screen investigations for low energetic electron beams at PITZ S. Rimjaem, J. Bähr, H.J. Grabosch, M. Groß Contents Review of PITZ setup Screens and beam profile monitors at PITZ Test results Summary
More informationPulseCounter Neutron & Gamma Spectrometry Software Manual
PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN
More informationQuick Guide Book of Sending and receiving card
Quick Guide Book of Sending and receiving card ----take K10 card for example 1 Hardware connection diagram Here take one module (32x16 pixels), 1 piece of K10 card, HUB75 for example, please refer to the
More informationTest Records. Scanning Test Records. This document provides a step-by-step tutorial on how to scan Test Records and verify the imported information.
Scanning Test Records This document provides a step-by-step tutorial on how to scan Test Records and verify the imported information. 1) From the Tools Menu, select Scanning Wizard. 2) Select Using Scanner
More informationPHI 5000 VersaProbe TM Operator s Guide
PHI 5000 VersaProbe TM Operator s Guide Part No. 705921 Rev. A Copyright 2006 ULVAC-PHI, INC. 370 Enzo, Chigasaki, JAPAN The PHI logo ( ) is a registered trademark of ULVAC-PHI, INC. Physical Electronics,
More informationAPPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software
APPLICATION NOTE Fiber Alignment Now Achievable with Commercial Software 55 Fiber Alignment Now Achievable with Commercial Software Fiber Alignment Fiber (or optical) alignment s goal is to find the location
More informationGVD-120 Galvano Controller
Becker & Hickl GmbH June 2007 Technology Leader in Photon Counting Tel. +49 / 30 / 787 56 32 FAX +49 / 30 / 787 57 34 http://www.becker-hickl.de email: info@becker-hickl.de GVD-120 Galvano Controller Waveform
More informationProfessional 4-channel Thermocouple Thermometer plus Infrared Thermometer
Professional 4-channel Thermocouple Thermometer plus Infrared Thermometer TIF3340 BUTTONS = Power ON or OFF. = Steps through maximum (MAX), minimum (MIN), and average (AVG) readings. To exit MAX / MIN
More informationReflecta Super 8 Scanner. User Manual
Reflecta Super 8 Scanner User Manual 1 FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT This Equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part
More informationLHC Beam Instrumentation Further Discussion
LHC Beam Instrumentation Further Discussion LHC Machine Advisory Committee 9 th December 2005 Rhodri Jones (CERN AB/BDI) Possible Discussion Topics Open Questions Tune measurement base band tune & 50Hz
More informationBitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.
BitWise. Instructions for New Features in ToF-AMS DAQ V2.1 Prepared by Joel Kimmel University of Colorado at Boulder & Aerodyne Research Inc. Last Revised 15-Jun-07 BitWise (V2.1 and later) includes features
More informationLedSet User s Manual V Official website: 1 /
LedSet User s Manual V2.6.1 1 / 42 20171123 Contents 1. Interface... 3 1.1. Option Menu... 4 1.1.1. Screen Configuration... 4 1.1.1.1. Instruction to Sender/ Receiver/ Display Connection... 4 1.1.1.2.
More informationXI'AN NOVASTAR TECH CO., LTD
Document number: NOVA2013-MCTRL660-HB-01 Version: V1.2.0 M3 Controller MCTRL660 User Manual Xi an NovaStar Tech Co., LTD 1 Overview MCTRL660, NovaStar's latest independent master control, is mainly applied
More informationTechnical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework
Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework 1.0 Purpose This technical procedure shall be followed for the operation of the Scanning
More informationWA-7000 Multi-line Wavemeter OPERATING MANUAL
WA-7000 Multi-line Wavemeter OPERATING MANUAL Operating Manual (Rev. A) 08435-M-00 Copyright Burleigh Instruments, Inc. 1999 All Rights Reserved Burleigh Instruments, Inc. Burleigh Park P.O. Box E Fishers,
More informationNetwork Disk Recorder WJ-ND200
Network Disk Recorder WJ-ND200 Network Disk Recorder Operating Instructions Model No. WJ-ND200 ERROR MIRROR TIMER HDD1 REC LINK /ACT OPERATE HDD2 ALARM SUSPEND ALARM BUZZER STOP Before attempting to connect
More informationMini Micro Pulse Lidar System
Mini Micro Pulse Lidar System MiniMPL-532-C Sensor Suite Operations Manual Version: June 2016 THIS PAGE INTENTIONALLY LEFT BLANK 2 Table of Contents MINIMPL SENSOR SUITE SYSTEM: RECORD OF PURCHASE... 4
More informationSpecifications LED Display Video Controller VX4. Xi an NovaStar Tech Co., Ltd. Rev1.0.4 NS
Specifications LED Display Video Controller VX4 Rev1.0.4 NS160110153 General Feature The VX4 is a professional LED display controller. Besides the function of display control, it also features in powerful
More informationTransmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
More informationNoise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0
CHEM 411L Instrumental Analysis Laboratory Revision 2.0 Noise In this laboratory exercise we will determine the Signal-to-Noise (S/N) ratio for an IR spectrum of Air using a Thermo Nicolet Avatar 360 Fourier
More informationUsing the Agilent for Single Crystal Work
Using the Agilent for Single Crystal Work Generally, the program to access the Agilent, CrysalisPro, will be open. If not, you can start the program using the shortcut on the desktop. There is no password
More informationSpecifications LED Display Video Controller VX4S
Specifications LED Display Video Controller VX4S Rev1.0.3 NS160110155 General The VX4S is a professional LED display controller. Besides the function of display control, it also features in powerful front
More informationCytoFLEX Flow Cytometer Quick Start Guide
Sheath Waste CLASS 1 LASER PRODUCT COMPLIES WITH 21 CFR 1040.10 AND 1040.11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO. 50 DATED JUNE 24, 2007 MANUFACTURED Sheath B49008AC February 2015 CytoFLEX
More informationBEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera
PRELIMINARY POWER DETECTORS ENERGY DETECTORS MONITORS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS CMOS Beam Profiling Camera AVAILABLE MODEL Beamage 3.0 (⅔ in CMOS
More information843-R 843-R LASER POWER METER USER MANUAL. NEWPORT CORPORATION
843-R 843-R LASER POWER METER USER MANUAL NEWPORT CORPORATION www.newport.com Table of Contents Chapter 1.Introduction: How to Use This Manual. 3 Chapter 2.Quick Reference... 4 2.1 Getting Started... 4
More informationSpecifications. Video Controller VX4U. Xi an NovaStar Tech Co., Ltd.
Specifications Video Controller VX4U Rev1.0.3 NS160100233 Overview Features VX4U is a professional LED display controller of NovaStar. Besides having all the functions of an LED display controller, it
More informationHIGH DEFINITION MONITOR HDM 5049 PLUS USER S MANUAL
BARCO N.V. Communication Systems Th. Sevenslaan 106 B-8500 Kortrijk (Belgium) Tel.: +32.56.233.211 Fax: + 32.56.233.461 E-mail: support.bcs@barco.com Web site: http://www.barco.com HIGH DEFINITION MONITOR
More informationValuNet Android ManageMyTVs Application User Guide
ValuNet Android ManageMyTVs Application User Guide Version 2.0 March 2014 ManageMyTVs Application NOTICE: before using this guide you must download and install the ManageMyTVs application from the Google
More informationCI-218 / CI-303 / CI430
CI-218 / CI-303 / CI430 Network Camera User Manual English AREC Inc. All Rights Reserved 2017. l www.arec.com All information contained in this document is Proprietary Table of Contents 1. Overview 1.1
More informationPart 1 Basic Operation
This product is a designed for video surveillance video encode and record, it include H.264 video Compression, large HDD storage, network, embedded Linux operate system and other advanced electronic technology,
More informationVIDEO GRABBER. DisplayPort. User Manual
VIDEO GRABBER DisplayPort User Manual Version Date Description Author 1.0 2016.03.02 New document MM 1.1 2016.11.02 Revised to match 1.5 device firmware version MM 1.2 2019.11.28 Drawings changes MM 2
More informationVirtual Vibration Analyzer
Virtual Vibration Analyzer Vibration/industrial systems LabVIEW DAQ by Ricardo Jaramillo, Manager, Ricardo Jaramillo y Cía; Daniel Jaramillo, Engineering Assistant, Ricardo Jaramillo y Cía The Challenge:
More informationCharacterization of Diamond Samples CHESS Run Summer 2013
Characterization of Diamond Samples CHESS Run Summer 2013 5/22 5/28/2013 Characterization of Diamond Samples CHESS Run Summer 2013 Useful information Goals for this run Conditions of the experiment 1.
More informationWINDOWS GUIDE LIBRESTREAM.COM
WINDOWS GUIDE Librestream Guide, Onsight for Windows OS Doc #: 400289-01, rev.a November 2016 Information in this document is subject to change without notice. Reproduction in any manner whatsoever without
More informationAndroid ManageMyTVs Application User Guide Version 3.0
Android ManageMyTVs Application User Guide Version 3.0 IPTV Middleware with Android Application Page 1 ManageMyTVs Application 1. To use the ManageMyTVs application, select the ManageMyTVs icon from the
More information111 Highland Drive Putnam, CT USA PHONE (860) FAX (860) SM32Pro SDK
SM32Pro SDK Spectrometer Operating -Software Development Kit- USER MANUAL For USB 2.0 Multi-channel User Only Table of Contents Warranty and Liability...3 Location of the SDK source code for USB 2.0...4
More informationLinrad On-Screen Controls K1JT
Linrad On-Screen Controls K1JT Main (Startup) Menu A = Weak signal CW B = Normal CW C = Meteor scatter CW D = SSB E = FM F = AM G = QRSS CW H = TX test I = Soundcard test mode J = Analog hardware tune
More informationProjector Management Application Version 7.00 Instruction Guide
Projector Management Application Version 7.00 Instruction Guide Contents 1 INTRODUCTION... 4 1.1 OUTLINE... 4 1.2 SYSTEM... 4 2 INSTALLATION... 5 2.1 SYSTEM REQUIREMENTS... 5 2.2 PROJECTOR MANAGEMENT APPLICATION
More informationOPTICAL POWER METER WITH SMART DETECTOR HEAD
OPTICAL POWER METER WITH SMART DETECTOR HEAD Features Fast response (over 1000 readouts/s) Wavelengths: 440 to 900 nm for visible (VIS) and 800 to 1700 nm for infrared (IR) NIST traceable Built-in attenuator
More informationElectron Beam Technology
Electron Beam Technology Best of both worlds: Direct write and direct view Ultra High Resolution Electron Beam Lithography and Scanning Electron Microscope Imaging MULTI TECHNIQUE ELECTRON BEAM LITHOGRAPHY
More informationScanning Entry Records Entry Records 1) Tools Menu Scanning Wizard 2) Using Scanner Hardware Contro 3) Entry Front Side 1
Scanning Entry Records This document provides a step-by-step tutorial on how to scan Entry Records and verify the imported information. 1) From the Tools Menu, select Scanning Wizard. 2) Select Using Scanner
More informationNOTES ON FACSCalibur USE AND TROUBLESHOOTING PROCEDURES. Department of Immunology Monash University 14/12/07
NOTES ON FACSCalibur USE AND TROUBLESHOOTING PROCEDURES Department of Immunology Monash University 14/12/07 Paul U Cameron paul.cameron@med.monash.edu.au Page Responsibilities of FACSCalibur users 3 Preparation
More informationUser Manual OVP Raman
Version 6 User Manual OVP Raman 2006 BRUKER OPTIK GmbH, Rudolf-Plank-Straße 27, D-76275 Ettlingen, www.brukeroptics.com All rights reserved. No part of this manual may be reproduced or transmitted in any
More informationSCode V3.5.1 (SP-601 and MP-6010) Digital Video Network Surveillance System
V3.5.1 (SP-601 and MP-6010) Digital Video Network Surveillance System Core Technologies Image Compression MPEG4. It supports high compression rate with good image quality and reduces the requirement of
More informationSCode V3.5.1 (SP-501 and MP-9200) Digital Video Network Surveillance System
V3.5.1 (SP-501 and MP-9200) Digital Video Network Surveillance System Core Technologies Image Compression MPEG4. It supports high compression rate with good image quality and reduces the requirement of
More informationUser s Manual. Network Board. Model No. WJ-HDB502
Network Board User s Manual Model No. WJ-HDB502 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. CONTENTS Introduction...
More informationSPATIAL LIGHT MODULATORS
SPATIAL LIGHT MODULATORS Reflective XY Series Phase and Amplitude 512x512 A spatial light modulator (SLM) is an electrically programmable device that modulates light according to a fixed spatial (pixel)
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationTracQ Basic. Spectroscopy Software v6.5. User's Manual
S TracQ Basic Spectroscopy Software v6.5 User's Manual Family of Brands ILX Lightwave New Focus Ophir Corion Richardson Gratings Spectra-Physics MTRACQBASIC6.5, Rev B 2 TABLE OF CONTENTS 1 SAFETY INFORMATION...
More informationDektak Step by Step Instructions:
Dektak Step by Step Instructions: Before Using the Equipment SIGN IN THE LOG BOOK Part 1: Setup 1. Turn on the switch at the back of the dektak machine. Then start up the computer. 2. Place the sample
More informationConnection for filtered air
BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers Instantly measure focus spot size Dynamically measure focal plane location during start-up From 1kW
More informationFRQM-2 Frequency Counter & RF Multimeter
FRQM-2 Frequency Counter & RF Multimeter Usage Instructions Firmware v2.09 Copyright 2007-2011 by ASPiSYS Ltd. Distributed by: ASPiSYS Ltd. P.O.Box 14386, Athens 11510 (http://www.aspisys.com) Tel. (+30)
More informationGetting Started with the LabVIEW Sound and Vibration Toolkit
1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool
More informationPASS. Professional Audience Safety System. User Manual. Pangolin Laser Systems. November 2O12
PASS Professional Audience Safety System User Manual November 2O12 Pangolin Laser Systems Downloaded from the website www.lps-laser.com of your distributor: 2 PASS Installation Manual Chapter 1 Introduction
More informationElectrical connection
Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication
More informationManageMyTVs App for AndroidTM
ManageMyTVs App for AndroidTM ManageMyTVs App 1. To use the ManageMyTVs app, tap the ManageMyTVs icon from the screen.the ManageMyTVs Sign-In screen will appear. 2. Enter your username in the Username
More informationCFlow User Guide. Science is hard. Flow cytometry should be easy.
CFlow User Guide Science is hard. Flow cytometry should be easy. Table of Contents Chapter 1 The Basics - Operating the Accuri C6 Flow Cytometer... 4 Introduction to CFlow and Running the C6... 4 CFlow
More informationON-THE-FLY SCANS FOR FAST TOMOGRAPHY AT LNLS IMAGING BEAMLINE. Gabriel B. Z. L. Moreno X-Ray Imaging Beamline Group, LNLS
ON-THE-FLY SCANS FOR FAST TOMOGRAPHY AT LNLS IMAGING BEAMLINE Gabriel B. Z. L. Moreno X-Ray Imaging Beamline Group, LNLS Experiment Control, ICALEPCS 2015 LNLS 1 d 3 h 2 Sirius Construction Site (July
More information16-BIT LOAD CELL/DUAL STATUS INPUT
16-BIT LOAD CELL/DUAL STATUS INPUT On-board Excitation. +5VDC, (120mA). State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. Optional Excitation
More informationHV/PHA Adjustment (PB) Part
HV/PHA Adjustment (PB) Part Contents Contents 1. How to set Part conditions...1 1.1 Setting conditions... 1 2. HV/PHA adjustment sequence...7 3. How to use this Part...9 HV/PHA Adjustment (PB) Part i
More informationOperation and Installation Guide
Operation and Installation Guide HDS2800 Series Encoder Modulator High Definition (HD) Digital COFDM MPEG2 and H.264 Modulator with IP Multicast. 19 Rack Mount Revision 4.0 Firmware version Released File
More informationMTS/T-BERD 8000 Platform
Key Features New optical design for field applications 50% reduction in size and weight for true OSNR measurements in ROADM networks Full spectral range of 1250 to 1650 nm for DWDM and CWDM testing High-resolution
More informationMCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010
MCP Signal Extraction and Timing Studies Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010 Outline Studying algorithms to process pulses from MCP devices. With the goal of
More informationChecking the fluids of the cart
1 Preparing FACSAria for sterile sorting Prepare and autoclave these fluids at least 2 days in advance: Fluids Remarks Prepare 5L (for 1 period) or 10L (for 2 Each stainless-steel-sheath-tank has a periods)
More informationPrecise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN BEAMS DEPARTMENT CERN-BE-2014-002 BI Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope M. Gasior; M. Krupa CERN Geneva/CH
More informationDigital Storage Oscilloscopes 2550 Series
Data Sheet Digital Storage Oscilloscopes 2550 Series The 2550 series digital storage oscilloscopes provide high performance and value in 2-channel and 4-channel configurations. With bandwidth from 70 MHz
More information