User Guide for the Early Countermeasure Model EmerSim of RODOS PRTY 6.0L

Size: px
Start display at page:

Download "User Guide for the Early Countermeasure Model EmerSim of RODOS PRTY 6.0L"

Transcription

1 User Guide for the Early Countermeasure Model EmerSim of RODOS PRTY 6.0L Irmgard Hasemann, Claudia Landman, Jürgen Päsler-Sauer STATUS: 23. November 2007 RODOS Version: PRTY 6.0L Contents USER GUIDE FOR THE EARLY COUNTERMEASURE MODEL EMERSIM OF RODOS PV6FINAL 1 1 Overview Brief description of the RODOS modelling of early countermeasures Tasks of the model EmerSim EmerSim Interval Input Output References 11 2 Starting an EmerSim run in the interactive mode Before starting the run Selection of results from ADM run Consideration of countermeasure input Starting the run Overview Start of interactive manager Selection of run option Selection of the RODOS ADM run on which the EmerSim run shall base on Start of EmerSim run without or with static initialisation Messages resulting from missing load lists during the different start phases, and corresponding user actions 15 3 Static Initialisation Windows for EmerSim Overview Starting and ending the static EmerSim initialisation Starting the static initialisation Ending the static initialisation (EmerSim-1.0) Startup-window for static early countermeasure items Determination of potential areas (Emersim-3.0) Areas: Input mode (Emersim-3.21) Area determination with intervention levels - Sector/Zone Option (Emersim-3.31 and subwindows) Area determination with graphics input Action selection and timing for selected actions (Emersim-4.0) Action selection Timing for selected actions (EmerSim-5.1) Timing for <sheltering only> (EmerSim-5.2) Timing for <evacuation only>

2 (EmerSim-5.12) Timing for <sheltering + evacuation> (EmerSim-5.3) Timing for <stable iodine only> 32 4 Dynamic Intervention Level Window (C/M-IL) for EmerSim 34 5 EmerSim results accessible with the RODOS Graphics Overview Preparing EmerSim results for graphical display [Potential Action Areas] Areas potentially affected by early countermeasures [Areas] The grid elements affected [Day of exceeding IL] Time point when the intervention level was exceeded [Groundshine] Development of ground level gamma dose with time [Organ Doses] Individual organ doses without and with actions [Population] [Spectra] Dose frequency distributions [Tables] Tables with countermeasure definitions and selected consequences 41 6 Trouble shooting General remarks EmerSim ends normally, but results look strange: Problem localisation Abnormal termination from fatal error caused by user input Location of countermeasure definition protocol, EmerSim run protocol, and consequence table on disk 44 7 Example runs 45 Document History

3 1 Overview 1.1 Brief description of the RODOS modelling of early countermeasures Tasks and performance of the model EmerSim An early countermeasure scenario in RODOS consists of combinations of the three single actions sheltering, evacuation, and administration of stable iodine, carried out in different areas and time intervals. The early countermeasures model of RODOS, EMERSIM, has three tasks: - The assessment of potential (that is, without the consideration of countermeasures) "open air" and "normal living" radiation doses on the whole calculation grid. - The determination of the areas and numbers of individuals potentially affected by the three early countermeasures mentioned above. - The assessment of radiation doses with simulation of the effects of early countermeasures in the potential action areas for those actions the user wants to consider. The early countermeasure simulation uses results from any of the near range atmospheric dispersion and deposition models (nearadm) of RODOS that describe - in each cell of the calculation grid - the spatial and temporal development of the radiological situation after an accidental release in the form of potential dose histories. These dose histories are generated by the nearadm in each cell of the calculation grid for a so called EmerSim-Interval (see Chapter 1.1.2) covering the last 24 hours or less of the dispersion calculation episode. Early countermeasures will only be simulated for this limited time period. In such modelling approach, a dose that an individual has received prior the EmerSim-Interval represents a dose pedestal that can no longer be mitigated by one of the actions, but does contribute to the overall dose. With the pedestal doses, EmerSim determines as additional information the areas where an intervention level has been exceeded at some time during the release, thus identifying all potential areas where early countermeasures might have been initiated in the past. For longer release scenarios, the described concept forces the user to consider exactly which scenario period of time shall be investigated in detail and define the timing for EmerSim accordingly. To calculate the dose reduction due to normal living behaviour of the population and to the effects of the early countermeasures, the potential "open air" dose histories are modified by factors depending on location and time, for example shielding factors (see below). Dose calculation in case of sheltering - 3 -

4 1.1.2 EmerSim Interval Until beginning and upon completion of sheltering, normal living of the population is assumed. The dose reduction during sheltering is simulated by using building type specific shielding factors for external cloud and ground gamma radiation. The shielding factors are defined as average values for each grid cell and are derived from the building types in that cell as contained in the RODOS data base. Similar shielding factors are applied for normal residence periods. Dose calculation in case of evacuation Before the start and during the ride out of the evacuation area, radiation exposure at the starting point is assumed for all evacuees. During the absence from the evacuation area, it is assumed that the evacuated persons are not exposed to any more accident-related radiation. After having returned, normal living is assumed. Hint: The user should assess the duration of the evacuation ride considering that the region with high exposure can be left during that time. Dose calculation in case of administration of stable iodine The intake of stable iodine causes a 100 % blocking of the thyroid against radioactive iodine after 15 minutes. Some dose reduction will still be achieved if stable iodine is applied within some hours after the inhalation of radioactive iodine, for example, 50 % for an intake delay of 4 hours after one single inhalation event. The time dependence of the reduction factor is modelled by an exponential function. In RODOS it is assumed that the intake of the stable iodine takes place simultaneously in the entire potential iodine tablets area. Prolonged inhalation is modelled by summing up the average contributions from each ADM time step. Note on relocation: Relocation areas are also determined in EmerSim because of the possible need for fast emergency management there. The intervention criteria in the early countermeasures model correspond to German modelling. Intervention criteria for International modelling can be specified only in the late countermeasures model of RODOS. A calculation episode in RODOS can cover in principle more than one month. However, on the one hand, early countermeasures like sheltering can be maintained for no longer than about a day in a given area. On the other hand, in case of an ongoing accident the time of interest is most probably close to the "now time", and there seems little sense in simulating in detail over so many days sequences of early countermeasures. In additiona, Numerical Weather Prediction data in case of a real event are limited to the nearest future, and accurate information about the source term might be restricted to several hours into the future only

5 On these grounds it was decided to carry out detailed calculations with the early countermeasure model EmerSim of RODOS only for a limited time period of 24 hours or shorter. This time period is called EmerSim-Interval and is determined by the time step length and the episode duration and of the underlying near range atmospheric dispersion and deposition model (ADM) calculations as follows. For an ADM time step length of 10 Minutes, the maximum duration of the EmerSim-interval is 8 hours; for an ADM time step length of 30 Minutes or 60 minutes, respectively, it is 24 hours. If the ADM episode duration is less or equal the maximum duration of the EmerSim-interval for the chosen ADM time step length, the EmerSim-interval is identical with the ADM episode. For an ADM episode duration exceeding the maximum duration of the EmerSim-interval, the EmerSim-interval will cover the last 8 (for 10 minutes ADM-time steps) or 24 hours (for half hour or hour ADM time steps) of the calculation episode, that is, it starts 8 or 24 hours before the end of the calculation episode. 1.2 Input The early countermeasures which can be considered in EmerSim are sheltering, evacuation, and the distribution of stable iodine tablets. In addition, EmerSim allows assessing relocation areas, because of the potential need for fast emergency management there. The user can tailor a countermeasure scenario with the Initialisation windows of RODOS. From RODOS PV6.0 Patch 07 onwards, there are several static and one dynamic initialisation window. Run data via the static windows must be given by the user before EmerSim starts. The static windows have to be opened actively by the user by pressing the button [Initialisation] in the (Start-Dialog) window, see Chapter Run data via the dynamic window are to be given during EmerSim execution. The dynamic window will appear automatically without request from the user. The countermeasure items that can be accessed, the Initialisation window hierarchy, and the default settings are shown in Fehler! Verweisquelle konnte nicht gefunden werden. on the following page

6 Table 1: EmerSim user input STATIC initialisation window hierarchy (EmerSim-1.0) Emergency actions Determination of potential areas (Emersim-3.0) Areas: Input mode (Emersim-3.21) Areas by intervention levels Option for extension to sectors/zones (Emersim-3.31) Areas by graphics input Sub-window for graphical input Action selection and timing parameters Action selection (Emersim-4.0) Action selection Timing parameters for selected actions (Emersim-5.1) Timing for <sheltering only> (Emersim-5.2) Timing for <evacuation only> (Emersim-5.3) Timing for <stable iodine only> (Emersim-5.12) Timing for <sheltering + evacuation> (Emersim-5.13) Timing for <sheltering + stab.iodine> (Emersim-5.23) Timing for <evacuation + stab.iodine > (Emersim-5.123) Timing for <shelter+evac+stab.iodine> STATIC initialisation window default settings No extension to sectors/zones. All actions selected. Timing set for maximum possible effect of each action DYNAMIC initialisation window (C/M-IL) Dose intervention levels DYNAMIC initialisation window default setting Country-specific default settings; for details see text

7 As can be seen from the table, there are three main input categories. 1. (STATIC initialisation) Determination of potential countermeasure areas The following selection can be made in window (EmerSim-3.0): For sheltering, evacuation, and distribution of stable iodine tablets: Determination of potential countermeasure areas either by intervention levels (default) or by graphical input. For Relocation: Only intervention levels are possible. If the determination of the areas shall be based on intervention levels, it is additionally possible to let the areas automatically become extended by RODOS to complete sectors/zones in window (EmerSim-3.21). The default is "no automatic extension". 2. (STATIC initialisation) Selection of early actions to be considered for carrying out Timing parameters for the selected actions The actions, which can be considered for carrying out, are sheltering, evacuation, and distribution of stable iodine tablets. The selection is made in window (EmerSim-4.0). By default, all three actions are switched on. Before selecting the timing parameters one has to remember, that EmerSim calculates detailed countermeasures only for the so called "EmerSim interval" which lasts over the last 24 hours of the dispersion calculation episode, or covers it completely if the episode is shorter than 24 hours. Thus actions will only be carried out during this time period, not affecting the doses the population has received up to the time, the action starts. For the actions to be considered for carrying out, timing parameters can be specified. Which window will appear depends on the selected single action or action combination. By default, the timing is set for the maximum possible effect of any action, that is, sheltering during complete plume passage in areas affected by sheltering, evacuation before plume arrival in areas affected by evacuation, and prophylactic intake of iodine tablets in areas affected by the distribution of stable iodine. 3. (DYNAMIC initialisation) Numerical values for dose intervention levels The dynamic window (C/M-IL) serves for the specification of dose intervention levels, for the three emergency actions sheltering, evacuation, iodine tablets, and additionally for relocation

8 From RODOS PV6.0 Patch 07 onwards, RODOS considers countryspecific intervention criteria for sheltering, evacuation, and iodine tablets. The selection of the country is done already in the atmospheric dispersion and deposition (ADM) run, on which the EmerSim-run bases on. The selection of the country activated the default intervention levels for the respective country, which are displayed when window (C/M-IL) opens up for the first time. These values can then be changed by the user. The definition of the dose concept (projected or averted dose), and the exposure pathways and integration times to be considered for the calculation of the intervention doses for each organ, for the comparison with the dose intervention levels, got also already defined in the ADM run, on which the current EmerSim-run bases; they cannot be changed at the level of EmerSim. Note on dose intervention levels for relocation: Relocation areas are assessed also in the early countermeasures model of RODOS because of the potential need for fast emergency management there. The intervention criteria on the level of the early countermeasures model correspond to German modelling. Intervention criteria for International modelling can be specified only on the level of the late countermeasures model of RODOS. 1.3 Output Tab. 1 shows the results and additional information of EmerSim that are accessible with the RODOS graphics, together with the keywords, under which the results can be located in the RODOS graphics, and the physical units. The results cover: Maps of the areas potentially affected by the early actions, and additionally for relocation. Furthermore, the day of exceeding the intervention level for all early emergency actions is displayed. This information is an indication of a potential problem, but no action was carried out in these calculated areas. The time development of gamma doses and gamma dose rates from contaminated ground surface (lawn). Maps of individual doses from the exposure to cloudshine, groundshine, and inhalation for several organs and integration times. Maps of individual skin doses from the exposure to contaminated skin and clothes. Maps of individual doses summed over the exposure pathways

9 Dose frequency distributions in the population. Number of people living in a RODOS grid cell Protocol of the countermeasure definitions used in a run. Table with selected consequences. The doses without emergency actions and without any radiation shielding are called open-air doses. The normal living doses result from additional location factors, which describe the shielding under average normal living conditions. Tab. 1: Output from EmerSim result key in graphics unit [Potential Action Areas] Areas potentially affected by countermeasures (detailed simulation of actions only performed during the EmerSim-Interval) [Areas] the grid elemets affected by the action sheltering [Sheltering] - evacuation [Evacuation] - stable iodine - children age 5 years - stable iodine, adults relocation - temporary - permanent [IodineTablets] -[Children] -[Adults] [Relocation] -[temporary] -[permanent] [Day of exceeding IL] Time for exceeding of a given intervention level at a certain grid point sheltering [Sheltering] days evacuation [Evacuation] days stable iodine - children age 5 years - stable iodine, adults [IodineTablets] -[Children] -[Adults] - - days [Groundshine] Development of ground gamma dose and rate with time (individual dose) For open air Effective dose rate by gamma radiation from ground [Rates] msv/h (adults only), curve with time points at the first days of scenario, additionally at +1,7,14,30 days,+0.5, 1, 50 years 1 Effective Ground gamma dose (adults only) [Doses] msv 1 For simplification the time points of the dose rate curves are drawn at the upper end of the time intervals, corresponding to those of the dose curves. By this the dose rate curves appear to be shifted systematically to bigger times. (The times of the average dose rates lie in the interval, not at the upper end)

10 curve with time points at the first days of the scenario, additionally at +1,7,14,30 days,+0.5, 1, 50 years [OrganDoses] Individual organ doses for exposure pathways cloud, ground, inhalation [NoAction] Without actions (for open air and normal living) [Action] With actions Cloud [Cloud] msv - integrated over plume passage - organs lung, bone marrow, thyroid, uterus, effective, skin - adults only Ground [Ground] msv - integrated over 1 day, 7 days, 30 days, 1 year, 50 years - organs lung, bone marrow, thyroid, uterus, effective, skin - adults only Inhalation, - integrated over 1 day, 7 days, 30 days, 1 year, 50 years - organs lung, bone marrow, thyroid, uterus, effective, skin - adults only - thyroid children age 5 years, integrated over 70 years [Inhalation] msv [OrganDoses] Doses for exposure to contaminated skin and clothes (individual dose, adults only) [NoAction] Without actions (for open air and normal living) [Action] With actions Local skin dose from self-irradiation of contaminated skin [LocalSkinDose] msv and clothes (alpha-, beta-, gamma-irradiation) accumulated over scenario length [OrganDoses] Doses summed up over exposure pathways Intervention Dose: Potential effective dose for comparison with intervention levels of early countermeasures (cloud gamma + ground gamma at least 7 days 2 + inhalation 50 years) Sum of organ doses from the exposure pathways cloud, ground (integrated over at least 7 days 2 ), inhalation (integrated over 50 years), plus organ dose resulting from skin and clothes during the scenario following the initial release (adults only) - without actions (for open air and normal living) and with actions - organs lung, bone marrow, thyroid, uterus, effective [Intervention Dose] [Sum] msv msv 2 Integration time exceeds 7 days for scenarios with duration longer than 7 days

11 [Spectra] Dose Frequency Distributions in the Population (individual dose, adults only) For organs lung, bone marrow, thyroid, uterus, effective [NoAction] Without actions (for open air and normal living) [Action] With actions Cloud, integrated over plume passage [Cloud] - Ground, integrated over at least 7 days 2 [Ground] - Inhalation, integrated over 50 years [Inhalation] - Sum of above results [Sum] - [Population] Number of people living in one RODOS grid cell Number of people living in one RODOS grid cell [Population] People /grid [Tables] Situation data protocols Countermeasure selection and timing [ActionData] - Selected consequences: Areas and people potentially [Consequences] - affected; collective doses; maximum doses 1.4 References In addition to the results shown in the table above, EmerSim also calculates data for the long-term countermeasure module LCMT, for the early consequence module EarlyCons, and the expert system module ESY. The general user has no access to these data. J. Päsler-Sauer, Model Description of the Early Countermeasures Module EmerSim in RODOS PV6final. Internal report RODOS(RA3)- TN(04)-03, Draft Version

12 2 Starting an EmerSim run in the interactive mode 2.1 Before starting the run Selection of results from ADM run To execute EmerSim, results of a previous run of one of the RODOS atmospheric dispersion and deposition (ADM) programs, QUICKPRO, ALSMC, or RLSMC, are required as input data for EmerSim. Consider which run from which program you want to use Consideration of countermeasure input 2.2 Starting the run Before starting an EmerSim run you should consider, for example with help of Fehler! Verweisquelle konnte nicht gefunden werden., if static input is required, or if the default settings for the static input items are sufficient for your purposes Overview Starting an interactive EmerSim run requires the following actions (in that order!): 1. (Cogent) Start of interactive manager 2. (Cogent) Selection of the RODOS ADM run on which the EmerSim run shall base on 3. (Cogent) Start of EmerSim without or with (Optional) previous static initialisation The countermeasure definitions used in each EmerSim run are recorded; see Chapter 5.8 for more details Start of interactive manager In the Main Dialogue menu of RODOS select the button [Interactive]. The Interactive Manager window appears

13 2.2.3 Selection of run option For details about the Interactive Manager window see [RODOS User Guide of the System Interface]. From RODOS PV6.0 Patch 07 onwards, it is recommended to use always the default run option default. For details about the meaning of the run option see [RODOS User Guide of the System Interface] Selection of the RODOS ADM run on which the EmerSim run shall base on In the tool bar of the Interactive Manager window, first press [Configuration] and then [Importing Result-Dataset to]. A window called Target Programs appears. In this window, choose EmerSim/QP when using the results of QUICKPRO, EmerSim/AL when using the results of ALSMC, EmerSim/RL when using the results of RLSMC. EmerSim/DL when using the results of DLSMC. A window appears in which all archived runs of all Atmospheric Dispersion Modules are listed. A run is selected by clicking on it and then pressing the button [Apply]. Attention (1): If you get an error message, although you carried out all steps in the correct way, proceed with the instructions in Chapter Attention (2): If results from another atmospheric dispersion module than the one implied by the selection EmerSim /QP, /AL, or /RL is chosen, an error message appears and the configuration is refused Start of EmerSim run without or with static initialisation In the Interactive Manager window, click on

14 [EmerSim/QP] when using the results of QUICKPRO, [EmerSim/AL] when using the results of ALSMC, [EmerSim/RL] when using the results of RLSMC. [EmerSim/DL] when using the results of DLSMC. The Start window pops up. First, enter the name you want to give to the run (the "Run-ID"). If your problem requires static initialisation, press [Initialising]. If the system then informs you, that there is no load list, and an automatic copy will be generated, proceed with the instructions in Chapter When the load list is present, Static Initialisation windows will open, which are described in detail in Chapters 3. On return from the Initialisation windows you automatically come back to the Start window. Start the EmerSim run by pressing on [Start]. After a while, a Dynamic Initialisation window will open, that is described in Chapter Fehler! Verweisquelle konnte nicht gefunden werden.. Or, you can cancel the start preparations by pressing [Cancel]. After the run has been started, the Control & Services window appears. This window is described in detail in [RODOS User Guide of the System Interface]. One feature, however, namely the [Info]-button, is of particular importance for EmerSim and is described here

15 The [Info]-button appears at the bottom of the Control & Services window, but only some time after EmerSim has left the INIT phase (use the [Process Status]-button of the Control & Services window to see where EmerSim is when running). On first appearance, the button has a violet colour and can be pressed (later, it gets grey and becomes inactive). A window opens which informs you about the site and the reactor block name, the size of the inner grid cells, and whether the areas are defined by intervention levels or by graphics input Messages resulting from missing load lists during the different start phases, and corresponding user actions If you wanted to carry out a configuration step in the Interactive Manager window, and an error message appears when the system is going to perform the configuration, although you carried out all steps in the correct way, this means that there is no load list. Then go to the Start window and click [Start]: The system will generate an automatic copy. You must wait until the ready-message appears, and then repeat the configuration step(s). If you wanted to carry out an initialisation step with the Initialisation windows, and the system informs you, that there is no load list, and an automatic copy will be generated, you first must wait until that was finished. Afterwards, you must repeat any configuration you have performed so far

16 3 Static Initialisation Windows for EmerSim 3.1 Overview All EmerSim Static Initialisation windows are arranged in the form of a tree. It is always possible to proceed to the next branch or return to the previous branch. Some of the windows have a [Help] button. By pressing this button, you get more information about the items in the corresponding menu. This button is omitted in the following menu descriptions. Some of the windows have a [Print] button. By pressing this button, you get a printout of the corresponding menu. This button is omitted in the following menu descriptions. The static initialisation windows shown in Chapters 3.3 to 3.5 are for an example run with run-name "demo". This run-name appears as the leftmost item [demo] in the title line of the windows. The static initialisation window hierarchy is summarised in Fehler! Verweisquelle konnte nicht gefunden werden Starting and ending the static EmerSim initialisation After having pressed [Initialising] in the Start window, the Program Initialisation window appears. On return from the EmerSim Static Initialisation windows you come back to this menu. For the meaning of the two buttons [single-display], which is the default, and [double-display] see [RODOS User Guide of the System Interface] Starting the static initialisation In the Program Initialisation window, click on EmerSim. Next, the Dataset Selection window comes up

17 This window switches between modification of the default data, or of either the data from the previous initialisation, or the data from another initialisation made earlier. After pressing the appropriate button (details not shown here), the first EmerSim initialisation menu EmerSim-1.0 pops up (see Chapter 3.3) Ending the static initialisation On return from the Static Initialisation windows you come back to the Program Initialisation window. Now you have three choices: To apply the input made in the Initialisation windows, click on [Apply]. After the system finished working, click on [Return]. To cancel all input made in the Initialisation windows and then start again with new input, click first on [unlock buttons], then proceed again from To ignore all input made in the Initialisation windows and start the program with the pre-set selections, click on [Return]. Leaving the EmerSim initialisation brings you back to the Start window. 3.3 (EmerSim-1.0) Startup-window for static early countermeasure items Menu EmerSim-1.0 is for the selection of items for early countermeasures that must be put in statically in RODOS. The subwindows for the actual input are accessed by clicking on Determination of potential areas, and on Action selection and timing parameters, which brings you to the menus Emersim-3.0 and Emersim-4.0, respectively

18 [Close] brings you back to the Program Initialisation window. 3.4 Determination of potential areas (Emersim-3.0) Areas: Input mode Clicking on Area determination with intervention levels (this is the default) and on Area determination with graphics input brings you to the menus Emersim-3.21 and Emersim-3.31, respectively. You can choose either one or the other mode, a combination of both is not possible. [Close] stores the selection and brings you back to the next upper menu (Emersim-3.21) Area determination with intervention levels - Sector/Zone Option In this window, you can specify, if the area determination shall be done on the basis of intervention levels (which can be defined in a dynamic window during run-time) exclusively (default), or on the basis of intervention levels, but extended to complete sectors/zones

19 In the first case, the areas only consist of those cells in the calculation grid, where the intervention levels are exceeded. In the second case, the entire sector of a distance zone is assumed to be affected by a countermeasure, if the intervention level is exceeded in at least one of the computation cells contained there-in. Outside of the area covered, it is proceeded as in the first case. [Close] exits the window without storing any input. [Update] confirms any input (Emersim-3.31 and subwindows) Area determination with graphics input To enable the area determination with graphics input for EmerSim, the Main Drawing Window must be open. After pressing the Area determination with graphics input button in the window EmerSim-3.0, the entry window for the graphical area input EmerSim-3.31 opens. There are two options for the graphical area input: [Modify archived areas]: Here, the graphical area input can be based on the results of a previous run; the action areas calculated there can be loaded into the Main Drawing Window, modified and then saved

20 At first, window Emersim-3.32 opens. Click to [Continue] and the window "List of Archived Runs" opens. If you want to go back without any input at this stage, click on [Close], which brings you back to the next upper level. If you want to go back without any input at this stage, click on [Close], which brings you back to the next upper level. Selecting one of the archived runs presented in the window means that you base your input on an already existing area determination created earlier, which you now want to modify graphically. The stored files are distinguished by "arch: run-id", which means "archived runs". Having made the selection, press [Apply] and window Emersim-3.33 will open. [New area input]: Selecting this button means that you want to input the areas graphically completely from scratch. After pressing the button, window Emersim-3.33 will open. Note that in this case you will not get relocation areas, because for them there exists no graphical input mode. Independent which of the two options for graphical input of areas you choose, you come to window Emersim-3.33, where you select the countermeasure or countermeasure combination for modification

21 If you want to enter sheltering and/or evacuation areas, press [Shelter+Evac.]. If you want to enter stable iodine tablet administration areas for adults or children, click on [Iodine Adults] or [Iodine Child.], respectively. You can modify the areas for all three actions one after the other. Note: The graphical input of relocation areas is not possible. If you want to go back without any input at this stage, click on [Close], which brings you back to the next upper level. After having chosen [Shelter+Evac.] or [Iodine Adults], or [Iodine Child.], either the results from the base run or empty areas will be shown in the Main Drawing Window. In the following, as an example it is assumed that [Shelter+Evac.] was selected; the successor window Input/Sheltering and Evacuation pops up. Now you have to do the following: In the Save to line, pull from [RIF file] to [Module] (but do not press [Save] yet!). Click on User Input. In the same line, you can select the input mode. By default, it is [Pencil mode]. In this mode, you can use the mouse pointer as a pencil and draw a line. Each grid cell hit by the line is then marked. Or you can pull this bar down from [Pencil mode] to [Area mode],

22 to enable drawing polygons. Each grid cell inside a polygon is then marked. Pull down the Value bar away from [0] (zero means no action) to the desired action or action combination. Go into the Main Drawing Window. Draw a polygon in [Area mode] with the left mouse button (repeated "click on polygon-corner, - pull line - click on next polygon-corner"). Close the polygon by pressing the right mouse button. By selecting [Redraw] in the Tool Bar of Main Drawing Window, the map is redrawn with the polygon area appearing in the colour of the selected action or action combination. Draw a line or point in [Pencil mode] with the left mouse button ("click on point - pull line - click on point", a little pull is necessary also for drawing a point). By selecting [Redraw] in the Tool Bar of the Main Drawing Window, the map is redrawn with the line area or grid cell appearing in the colour of the selected action or action combination. Repeat above actions as often as necessary until the desired action pattern is achieved, eventually with switching the mode or the value. Click on [Save] in the Input/Sheltering and Evacuation window, which then disappears. Now you are back in the countermeasure selection window for the graphical area input, EmerSim-3.33, where you can choose another action to modify the corresponding area. [Close] exits the window without storing any input; [Update] confirms any input. After that, exit the EmerSim input and start a new run with the graphically defined early countermeasure areas (and, of course, all eventual input made for the timing parameters). 3.5 Action selection and timing for selected actions (Emersim-4.0) Action selection In window EmerSim-4.0, select those countermeasures, the performance of which shall be computed in the potentially affected area. Each of the countermeasures listed in the window can be switched on and off (switched on: key in pressed position; switched off: key is not pressed). By default, all three actions are switched on

23 3.5.2 Timing for selected actions If you only want to inspect which actions are active without further changes to the selection or input of timing parameters, simply click on [Close], which brings you back to the next upper level. If you want to activate or de-activate actions, but without modification of timing parameters, first activate or de-activate the action(s). Then click on [Update], which brings you back to the next upper level. If you have switched off all actions, a window EmerSim-4.1 will appear to inform you about this, in which you must click on [Close], which brings you back to the next upper level. If you want to activate or de-activate actions with modification of timing parameters, first activate or de-activate the action(s). Then click on [Timing], which brings you to the window for the input of the timing parameters. Upon completion of entering the timing parameters, click on [Update], which brings you back to the next upper level. After the click on [Timing] in window EmerSim-4.0, a successor window pops up for the input of the timing parameters. Which window will appear depends on which countermeasures have been activated (see also Fehler! Verweisquelle konnte nicht gefunden werden.). For the countermeasures sheltering and evacuation, three combinations exist: - Sheltering (without evacuation), - Evacuation (without sheltering), - Sheltering and evacuation. In addition, the countermeasure distribution of stable iodine can be studied either as an individual countermeasure or in combination with sheltering or evacuation. The input windows for sheltering (EmerSim-5.1), evacuation (EmerSim-5.2), stable iodine (EmerSim-5.3) as single actions, and for the combined action sheltering+evacuation (EmerSim-5.12) are shown

24 and explained in the following chapters. If stable iodine was selected in addition to sheltering, evacuation, or sheltering+evacuation, the same input as for the iodine action alone appears in the bottom of the respective window for the action combination. The corresponding windows (EmerSim-5.13), (EmerSim-5.23), (EmerSim-5.123) are combinations of the windows already explained and are not shown again. Please remember, that all emergency actions are assumed to be performed in the so-called EmerSim-Interval (see also Chapter 1.1.2): If the ADM episode duration is less or equal the maximum duration of the EmerSim-interval for the chosen ADM time step length, the EmerSim-interval is identical with the ADM episode. For an ADM episode duration exceeding the maximum duration of the EmerSim-interval, the EmerSim-interval will cover the last 8 (for 10 minutes ADM-time steps) or 24 hours (for half hour or one hour ADM time steps) of the calculation episode, that is, it starts 8 or 24 hours before the end of the calculation episode. With respect to action timing specifications for EmerSim, please note: All action timing specifications refer to the beginning of the EmerSim-interval. All timing specifications should be given in multiples of the ADM time step length. If this is not so, times get rounded to the nearest ADM time step multiple, and a corresponding message is written into the protocol of the countermeasure definitions. Action durations exceeding the EmerSim-interval are cut to the end of the EmerSim-interval. Is not allowed to request an action to start beyond the EmerSiminterval. Example (for an ADM time step of 30 minutes or 1 hour): Start of prognosis calculation: End of prognosis calculation :15 o' clock :40 o' clock. The EmerSim-Interval will start on at 18:40 and ends on at 18:40, i.e. it lasts 24 hours. Emergency actions are simulated only for this time period. All actions performed are ended after this time period

25 (EmerSim-5.1) Timing for <sheltering only> The timing is illustrated in Figure 1. For the action <sheltering only>, before the start and after completion of the action normal living is assumed for the population in the sheltering area. During sheltering, the people in the sheltering area are supposed to stay in buildings with the respective shielding properties taken from the geographical database. In the input window, which is shown below, specify the start and the duration of sheltering. All times apply for the entire area potentially affected by <sheltering only>. The start-time must be given relative to the time point <begin of EmerSim-Interval>. If the start-time is beyond the end of the EmerSim-Interval (that means also beyond the end of the prognosis period), the program will stop. For the example above 3, the following is not allowed: Start of sheltering = 24.5 hours, i.e. on at 19:10. begin of EmerSim-Interval 0 duration of sheltering start of sheltering Figure 1: Timing for sheltering without evacuation If the start-time does not lie beyond the EmerSim-Interval, but the end of sheltering does so, sheltering is assumed to terminate with the end of the prognosis. For the example above 4 : 3 This example refers to an ADM time step length of 30 or 60 minutes. 4 This example refers to an ADM time step length of 30 or 60 minutes

26 - Start of sheltering = 4.5 hours, i.e. on at 23:10. - User-specified duration of sheltering = 22 hours, i.e. sheltering would end at 21:10 on ; - Assumed end of sheltering in EmerSim, however, at 18:40 on , i.e. duration of sheltering is cut to 19.5 hours. The duration of sheltering can have a maximal value of 24 hours; in this case the sheltering must start at time 0. The default timing for <sheltering only> is set up for "sheltering from the start of the EmerSim-Interval until end of the prognosis". Note that all times should be given in multiples of the ADM time step length. If this is not so, times get rounded to the nearest ADM time step multiple. A Corresponding message gets written into the protocol of the countermeasure definitions. [Close] exits the window without storing any input. [Update] confirms any input (EmerSim-5.2) Timing for <evacuation only> The timing is illustrated in Figure 2. For the action <evacuation only>, before the start normal living is assumed for the population in the evacuation area. During the ride out of the evacuation area, radiation exposure at the starting point is assumed for all evacuees. During the absence from the evacuation area, it is assumed that the evacuated persons are not exposed to any further accident-related radiation. After the people have returned, normal living is assumed again. In the input window, which is shown below, first specify the start of the evacuation. Then specify the duration of the travel time to leave the evacuation area, and the duration of absence from the area. All times

27 apply for the entire area potentially affected by <evacuation only>. The start-time must be given relative to the time point <begin of EmerSim- Interval>. begin of EmerSim-Interval 0 evacuation travel time duration of absence from evacuation area start of evacuation people returning from evacuation Figure 2: Timing for evacuation without sheltering If the start-time is beyond the end of the EmerSim-Interval, the program will stop. For the example above the following is not allowed: Start of evacuation = 25 hours, i.e. on at 19:40. If the start-time does not lie the beyond the EmerSim-Interval, but the end of the evacuation travel time does so, it is assumed that evacuation is completed with the end of the prognosis. For the example above 5 : - Start of evacuation = 20.5 hours, i.e. on at 15:10. - User-specified evacuation travel time = 5 hours, i.e. evacuation would be completed on at 20:10; - Assumed completion of evacuation in EmerSim, however, on at 18:40, i.e. travel time is cut to 3.5 hours. 5 This example refers to an ADM time step length of 30 or 60 minutes

28 The default timing for <evacuation only> is set up to be completed with the end of the EmerSim-Interval. This is achieved by specifying zero for the start of the evacuation and for the duration of the travel time to leave the evacuation area. The default duration of absence from the evacuation area is 30 days. Note that all times should be given in multiples of the ADM time step length. If this is not so, times get rounded to the nearest ADM time step multiple. A Corresponding message gets written into the protocol of the countermeasure definitions. [Close] exits the window without storing any input. [Update] confirms any input (EmerSim-5.12) Timing for <sheltering + evacuation> For simultaneous simulation of sheltering and evacuation, three areas may be distinguished as a function of the radiological situation and the intervention levels selected: 1. An area that is only affected by sheltering, but not by evacuation. 2. An area that is only affected by evacuation, but not by sheltering. 3. An area that is affected by both sheltering and evacuation. The three areas and the respective timing in RODOS are illustrated in Figure 3. In the area only affected by sheltering, but not by evacuation, before the start and after completion of the action normal living is assumed for the population in the area. During sheltering, the people in the area are supposed to stay in buildings with the respective shielding properties taken from the geographical database

29 Area "Sheltering Only" begin of EmerSim-Interval 0 duration of sheltering start of sheltering Area "Sheltering followed by Evacuation" and area "Evacuation" begin of EmerSim-Interval 0 duration of sheltering evacuation travel time duration of absence from evacuation area start of sheltering start of evacuation people returning from evacuation Figure 3: Areas and timings for sheltering plus evacuation In the area affected by evacuation, the following assumptions hold irrespective from parts of the area eventually also being affected by sheltering: The evacuation begins with the specified start time. During the ride out of the evacuation area, radiation exposure at the starting point is assumed for all evacuees. During the absence from the evacuation area, it is assumed that the evacuated persons are not exposed to any further accident-related radiation. After the people have returned, normal living is assumed. However, the assumptions for the time prior to the start of the evacuation are different in the parts of the evacuation area affected by evacuation only, and by sheltering and evacuation, respectively: In the part affected by evacuation, but not by sheltering, normal living is assumed for all people. In the part affected by both sheltering and evacuation, during the sheltering period the people are supposed to stay in buildings with the respective shielding properties taken from the geographical database. Before the start of sheltering, or in the time period between the end of sheltering and the start of evacuation (if there is

30 such a time gap in the user specifications), normal living is assumed for all people. Window EmerSim-5.12 for the input of the timing parameters for the combined action <sheltering+evacuation> is shown below. As the window is rather large, it is shown in two parts to demonstrate all items. All start-times must be given relative to the time point <begin of EmerSim-Interval>. All times apply for the entire area potentially affected by the respective action or action combination. Window (EmerSim-5.12) Upper part- The upper part of window EmerSim-5.12 serves for the input for the area only affected by sheltering, but not by evacuation. There, specify the start and the duration of sheltering for this region. If the start-time is beyond the end of the EmerSim-Interval, the program will stop. If the start-time does not exceed the EmerSim-Interval, but the duration does so, sheltering is assumed to terminate with the end of the EmerSim-Interval. The default timing for the <sheltering only> area is set up for "sheltering from the start of the EmerSim-Interval until end of prognosis" (the prognosis duration is per default 24 hours and can be changed in the atmospheric dispersion program by the user). This is achieved by specifying 0 for the start of sheltering, and 24 hours for the sheltering duration

31 The lower part of window EmerSim-5.12 serves for the input for the area affected by evacuation only and sheltering + evacuation, respectively. For sheltering, specify the start and the duration of sheltering for this region. For evacuation, first specify the start of the evacuation. Then specify the duration of the ride out of the evacuation area, and the duration of absence from the area. If the duration of sheltering exceeds the start time of evacuation, it is assumed that the duration of sheltering is cut and the people evacuate with the specified start time of evacuation. Note, however, that the start of sheltering must be earlier than the start of evacuation. Violation of this constraint will lead to an error stop with a respective error message. Window (EmerSim-5.12) Lower part- If the start-time for evacuation is beyond the EmerSim-Interval, the program will stop. If the start-time does not exceed the EmerSim- Interval, but the travel time out of the evacuation area does so, it is assumed that evacuation is completed with the end of the EmerSim- Interval. The default timing for the <evacuation > area is set up so that evacuation is to be completed without any sheltering period with the start of the EmerSim-Interval. This is achieved by specifying 0 for the start of the evacuation and for the duration of the evacuation travel time as well as for the start and the duration of sheltering in the

32 evacuation area. The default duration of absence from the evacuation area is 30 days. Note that all times should be given in multiples of the ADM time step length. If this is not so, times get rounded to the nearest ADM time step multiple. A Corresponding message gets written into the protocol of the countermeasure definitions. [Close] exits the window without storing any input. [Update] confirms any input (EmerSim-5.3) Timing for <stable iodine only> The timing is illustrated in Figure 4Fehler! Verweisquelle konnte nicht gefunden werden.. In the entire area potentially affected by the distribution of iodine tablets, it is assumed that the intake of the iodine tablets takes place at the same time. In the input window, which is shown below, specify the intake of the iodine tablets relative to the time point <begin of EmerSim-Interval>. If the intake-time is beyond the EmerSim-Interval, the program will stop. begin of EmerSim-Interval 0 Intake of stable iodine Figure 4: Timing for the distribution of stable iodine The default timing for <stable iodine> is set up for intake of the tablets with the start of the EmerSim-Interval. This is achieved by specifying 0 for the intake time

33 Note that all times should be given in multiples of the ADM time step length. If this is not so, times get rounded to the nearest ADM time step multiple. A Corresponding message gets written into the protocol of the countermeasure definitions. [Close] exits the window without storing any input. [Update] confirms any input

34 4 Dynamic Intervention Level Window (C/M-IL) for EmerSim From RODOS PV6.0 Patch 07 onwards, there is one dynamic initialisation window, (C/M-IL), which will appear automatically when EmerSim runs, without request from the user. The window shown below is for an example run with run-name "emersim". This run-name appears as the leftmost item [emersim] in the title line of the window. Window (C/M-IL) serves for the specification of dose intervention levels, for different organs, for the three emergency actions sheltering, evacuation, iodine tablets (adults and children), and additionally for relocation 6. 6 Relocation areas are assessed also in the early countermeasures model of RODOS because of the potential need for fast emergency management there. The intervention criteria on the level of the early countermeasures model correspond to German modelling. Intervention criteria for International modelling can be specified only on the level of the late countermeasures model of RODOS

With Export all setting information (preferences, user setttings) can be exported into a text file.

With Export all setting information (preferences, user setttings) can be exported into a text file. Release Notes 1 Release Notes What s new in release 1.6 Version 1.6 contains many new functions that make it easier to work with the program and more powerful for users. 1. Preferences Export Menu: Info

More information

VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below.

VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below. VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below. Number Title Page Number 1 Adding actuated signal control to an

More information

MODFLOW - Grid Approach

MODFLOW - Grid Approach GMS 7.0 TUTORIALS MODFLOW - Grid Approach 1 Introduction Two approaches can be used to construct a MODFLOW simulation in GMS: the grid approach and the conceptual model approach. The grid approach involves

More information

v. 8.0 GMS 8.0 Tutorial MODFLOW Grid Approach Build a MODFLOW model on a 3D grid Prerequisite Tutorials None Time minutes

v. 8.0 GMS 8.0 Tutorial MODFLOW Grid Approach Build a MODFLOW model on a 3D grid Prerequisite Tutorials None Time minutes v. 8.0 GMS 8.0 Tutorial Build a MODFLOW model on a 3D grid Objectives The grid approach to MODFLOW pre-processing is described in this tutorial. In most cases, the conceptual model approach is more powerful

More information

VNS2200 Amplifier & Controller Installation Guide

VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation 1. Determine the installation location for the VNS2200 device. Consider the following when determining the

More information

Import and quantification of a micro titer plate image

Import and quantification of a micro titer plate image BioNumerics Tutorial: Import and quantification of a micro titer plate image 1 Aims BioNumerics can import character type data from TIFF images. This happens by quantification of the color intensity and/or

More information

Instructions for DataMark PDF Temperature Logger

Instructions for DataMark PDF Temperature Logger Instructions for DataMark PDF Temperature Logger DataMark provides a convenient way to obtain high accuracy temperature data in transit. The unit is a self contained temperature logger that plugs directly

More information

Background. About automation subtracks

Background. About automation subtracks 16 Background Cubase provides very comprehensive automation features. Virtually every mixer and effect parameter can be automated. There are two main methods you can use to automate parameter settings:

More information

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD 610 N. Whitney Way, Suite 160 Madison, WI 53705 Phone: 608.238.2171 Fax: 608.238.9241 Email:info@powline.com URL: http://www.powline.com Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

More information

dbtechnologies QUICK REFERENCE

dbtechnologies QUICK REFERENCE dbtechnologies QUICK REFERENCE 1 DVA Composer Ver3.1 dbtechnologies What s new in version 3.1 COMPOSER WINDOW - DVA T8 line array module now available in the System Models window. - Adding modules in the

More information

GS122-2L. About the speakers:

GS122-2L. About the speakers: Dan Leighton DL Consulting Andrea Bell GS122-2L A growing number of utilities are adapting Autodesk Utility Design (AUD) as their primary design tool for electrical utilities. You will learn the basics

More information

Yellow Frog. Manual Version 1.1

Yellow Frog. Manual Version 1.1 Yellow Frog Manual Version 1.1 1 YellowFrog Contents PC Requirements...... 2 YellowFrog Power Meter Measurement.... 3 YellowFrog PC Software..... 3 Main Screen....... 4 Input Overload....... 5 Battery

More information

VNS2210 Amplifier & Controller Installation Guide

VNS2210 Amplifier & Controller Installation Guide VNS2210 Amplifier & Controller Installation Guide VNS2210 Amplifier & Controller Installation 1. Determine the installation location for the VNS2210 device. Consider the following when determining the

More information

Source/Receiver (SR) Setup

Source/Receiver (SR) Setup PS User Guide Series 2015 Source/Receiver (SR) Setup For 1-D and 2-D Vs Profiling Prepared By Choon B. Park, Ph.D. January 2015 Table of Contents Page 1. Overview 2 2. Source/Receiver (SR) Setup Main Menu

More information

OPERATION MANUAL OF MULTIHEAD WEIGHER

OPERATION MANUAL OF MULTIHEAD WEIGHER OPERATION MANUAL OF MULTIHEAD WEIGHER Page 1 of 62 PREFACE Multihead weigher is automatic weighing equipment by using MCU control system to achieve high speed, accuracy and stable performance. Different

More information

Blueline, Linefree, Accuracy Ratio, & Moving Absolute Mean Ratio Charts

Blueline, Linefree, Accuracy Ratio, & Moving Absolute Mean Ratio Charts INTRODUCTION This instruction manual describes for users of the Excel Standard Celeration Template(s) the features of each page or worksheet in the template, allowing the user to set up and generate charts

More information

PS User Guide Series Seismic-Data Display

PS User Guide Series Seismic-Data Display PS User Guide Series 2015 Seismic-Data Display Prepared By Choon B. Park, Ph.D. January 2015 Table of Contents Page 1. File 2 2. Data 2 2.1 Resample 3 3. Edit 4 3.1 Export Data 4 3.2 Cut/Append Records

More information

Pre-processing of revolution speed data in ArtemiS SUITE 1

Pre-processing of revolution speed data in ArtemiS SUITE 1 03/18 in ArtemiS SUITE 1 Introduction 1 TTL logic 2 Sources of error in pulse data acquisition 3 Processing of trigger signals 5 Revolution speed acquisition with complex pulse patterns 7 Introduction

More information

Processes for the Intersection

Processes for the Intersection 7 Timing Processes for the Intersection In Chapter 6, you studied the operation of one intersection approach and determined the value of the vehicle extension time that would extend the green for as long

More information

User Manual OVP Raman

User Manual OVP Raman Version 6 User Manual OVP Raman 2006 BRUKER OPTIK GmbH, Rudolf-Plank-Straße 27, D-76275 Ettlingen, www.brukeroptics.com All rights reserved. No part of this manual may be reproduced or transmitted in any

More information

Table of Contents. iii

Table of Contents. iii Rental Table of Contents Introduction... 1 Technical Support... 1 Overview... 2 Getting Started... 3 Inventory Folders for Rental Items... 3 Rental Service Folders... 3 Equipment Inventory Folders...

More information

Printed Documentation

Printed Documentation Printed Documentation Table of Contents INTRODUCTION... 1 Technical Support... 1 Overview... 2 GETTING STARTED... 3 Inventory Folders for Rental Items... 3 Rental Service Folders... 4 Equipment Inventory

More information

Eagle Business Software

Eagle Business Software Rental Table of Contents Introduction... 1 Technical Support... 1 Overview... 2 Getting Started... 5 Inventory Folders for Rental Items... 5 Rental Service Folders... 5 Equipment Inventory Folders...

More information

ExtIO Plugin User Guide

ExtIO Plugin User Guide Overview The SDRplay Radio combines together the Mirics flexible tuner front-end and USB Bridge to produce a SDR platform capable of being used for a wide range of worldwide radio and TV standards. This

More information

Chapter 23 Dimmer monitoring

Chapter 23 Dimmer monitoring Chapter 23 Dimmer monitoring ETC consoles may be connected to ETC Sensor dimming systems via the ETCLink communication protocol. In this configuration, the console operates a dimmer monitoring system that

More information

CLIPSTER. 3D LUT File Generation with the Kodak Display Manager. Supplement

CLIPSTER. 3D LUT File Generation with the Kodak Display Manager. Supplement Supplement: CLIPSTER 3D LUT File Generation with the Kodak Display Manager (Version 1.0) CLIPSTER 3D LUT File Generation with the Kodak Display Manager Supplement Supplement for the CLIPSTER Documentation:

More information

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work?

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work? Positive Attendance Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work? Setup Security Codes Absence Types Absence Reasons Attendance Periods/Bell

More information

invr User s Guide Rev 1.4 (Aug. 2004)

invr User s Guide Rev 1.4 (Aug. 2004) Contents Contents... 2 1. Program Installation... 4 2. Overview... 4 3. Top Level Menu... 4 3.1 Display Window... 9 3.1.1 Channel Status Indicator Area... 9 3.1.2. Quick Control Menu... 10 4. Detailed

More information

A Matlab toolbox for. Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE

A Matlab toolbox for. Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE Centre for Marine Science and Technology A Matlab toolbox for Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE Version 5.0b Prepared for: Centre for Marine Science and Technology Prepared

More information

SIDRA INTERSECTION 8.0 UPDATE HISTORY

SIDRA INTERSECTION 8.0 UPDATE HISTORY Akcelik & Associates Pty Ltd PO Box 1075G, Greythorn, Vic 3104 AUSTRALIA ABN 79 088 889 687 For all technical support, sales support and general enquiries: support.sidrasolutions.com SIDRA INTERSECTION

More information

Linkage 3.6. User s Guide

Linkage 3.6. User s Guide Linkage 3.6 User s Guide David Rector Friday, December 01, 2017 Table of Contents Table of Contents... 2 Release Notes (Recently New and Changed Stuff)... 3 Installation... 3 Running the Linkage Program...

More information

Housing Inventory Setup Guide

Housing Inventory Setup Guide The following guide should allow users with residential programs to become more familiar with the inventory setup and maintenance functions within the PA HMIS/Client Track system. This guide will walk

More information

Operation/Users Manual

Operation/Users Manual Operation/Users Manual 48-1-21 Please forward any suggestions or errors to: jillas@daumar.es 6- OPERATION MANUAL FOR MACHINE 48 VERSION 48-1-21 This document is made up of the following sections: COMPULSORY

More information

GBA 327: Module 7D AVP Transcript Title: The Monte Carlo Simulation Using Risk Solver. Title Slide

GBA 327: Module 7D AVP Transcript Title: The Monte Carlo Simulation Using Risk Solver. Title Slide GBA 327: Module 7D AVP Transcript Title: The Monte Carlo Simulation Using Risk Solver Title Slide Narrator: Although the use of a data table illustrates how we can apply Monte Carlo simulation to a decision

More information

inside i-guidetm user reference manual 09ROVI1204 User i-guide Manual R16.indd 1

inside i-guidetm user reference manual 09ROVI1204 User i-guide Manual R16.indd 1 inside i-guidetm user reference manual 09ROVI1204 User i-guide Manual R16.indd 1 4/6/10 12:26:18 PM Copyright 2010 Rovi Corporation. All rights reserved. Rovi and the Rovi logo are trademarks of Rovi Corporation

More information

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

Cyan Sample. Forward T Software. Infotainment Channel Design Sample. Revision as of January 22, 2009 г. Instruction on Installation and Use

Cyan Sample. Forward T Software. Infotainment Channel Design Sample. Revision as of January 22, 2009 г. Instruction on Installation and Use Forward T Software Cyan Sample Infotainment Channel Design Sample Revision as of January 22, 2009 г. Instruction on Installation and Use SoftLab-NSK Notice The information in this document is subject to

More information

Table of Contents. 2 Select camera-lens configuration Select camera and lens type Listbox: Select source image... 8

Table of Contents. 2 Select camera-lens configuration Select camera and lens type Listbox: Select source image... 8 Table of Contents 1 Starting the program 3 1.1 Installation of the program.......................... 3 1.2 Starting the program.............................. 3 1.3 Control button: Load source image......................

More information

PulseCounter Neutron & Gamma Spectrometry Software Manual

PulseCounter Neutron & Gamma Spectrometry Software Manual PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN

More information

WindData Explorer User Manual

WindData Explorer User Manual WindData Explorer User Manual Revision History Revision Date Status 1 April 2014 First Edition Contents I Framework 4 1 Introduction 5 2 System Requirements 5 3 System Architecture 5 4 Graphical User Interface

More information

Operation Manual OPERATION MANUAL ISL. Precision True Peak Limiter NUGEN Audio. Contents

Operation Manual OPERATION MANUAL ISL. Precision True Peak Limiter NUGEN Audio. Contents ISL OPERATION MANUAL ISL Precision True Peak Limiter 2018 NUGEN Audio 1 www.nugenaudio.com Contents Contents Introduction Interface General Layout Compact Mode Input Metering and Adjustment Gain Reduction

More information

TOMELLERI ENGINEERING MEASURING SYSTEMS. TUBO Version 7.2 Software Manual rev.0

TOMELLERI ENGINEERING MEASURING SYSTEMS. TUBO Version 7.2 Software Manual rev.0 TOMELLERI ENGINEERING MEASURING SYSTEMS TUBO Version 7.2 Software Manual rev.0 Index 1. Overview... 3 2. Basic information... 4 2.1. Main window / Diagnosis... 5 2.2. Settings Window... 6 2.3. Serial transmission

More information

Quick Start Guide. Multidimensional Imaging

Quick Start Guide. Multidimensional Imaging Quick Start Guide Multidimensional Imaging Printed 11/2012 Multidimensional Imaging Content Quick Start Guide Content 1 Introduction 4 2 Set up multi-channel experiments 5 2.1 Set up a new experiment

More information

Quick-Start for READ30

Quick-Start for READ30 Quick-Start for READ30 The program READ30 was written for the purpose of reading and configuring the digital pressure-transmitter of the series 30. The two features are divided into the following parts:

More information

Smart Control SC16 3-Channel for matrix

Smart Control SC16 3-Channel for matrix Operating Manual Smart Control SC16 3-Channel for matrix Dear Customer, Thank you for choosing a WALTRON daytime lighting controller. Your daytime lighting controller is a high-quality product that was

More information

Grid Interactive Advanced Features Self-Supply Mode

Grid Interactive Advanced Features Self-Supply Mode Grid Interactive Advanced Features Self-Supply Mode CHILICON POWER MICROINVERTERS AND CP-100 CORTEX GATEWAY SYSTEM OVERVIEW Chilicon Power Advanced Inverter functions Power Factor Control: -0.8 to +0.8

More information

Analyzing Modulated Signals with the V93000 Signal Analyzer Tool. Joe Kelly, Verigy, Inc.

Analyzing Modulated Signals with the V93000 Signal Analyzer Tool. Joe Kelly, Verigy, Inc. Analyzing Modulated Signals with the V93000 Signal Analyzer Tool Joe Kelly, Verigy, Inc. Abstract The Signal Analyzer Tool contained within the SmarTest software on the V93000 is a versatile graphical

More information

Synergy SIS Attendance Administrator Guide

Synergy SIS Attendance Administrator Guide Synergy SIS Attendance Administrator Guide Edupoint Educational Systems, LLC 1955 South Val Vista Road, Ste 210 Mesa, AZ 85204 Phone (877) 899-9111 Fax (800) 338-7646 Volume 01, Edition 01, Revision 04

More information

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-018: Answers for infrastructure and cities. SIPROTEC 5 - Application: SIP5-APN-018 Breaker-and-a-half Automatic reclosing and leader follower

More information

Deltasoft Services M A N U A L LIBRARY MANAGEMENT. 1 P a g e SCHOOL MANAGEMENT SYSTEMS. Deltasoft. Services. User Manual. Aug 2013

Deltasoft Services M A N U A L LIBRARY MANAGEMENT. 1 P a g e SCHOOL MANAGEMENT SYSTEMS. Deltasoft. Services. User Manual. Aug 2013 1 P a g e Deltasoft Services User Manual Aug 2013 2 P a g e Introductions Library Management covers the following features: Books database Books grouping, Shelves management, Multiple copies, Conditions

More information

Go! Guide: The Notes Tab in the EHR

Go! Guide: The Notes Tab in the EHR Go! Guide: The Notes Tab in the EHR Introduction The Notes tab in the EHR contains narrative information about a patient s current and past medical history. It is where all members of the health care team

More information

The DataView PowerPad III Control Panel

The DataView PowerPad III Control Panel Setting Up a Recording Session in the DataView PowerPad III Control Panel By Mike Van Dunk The DataView PowerPad III Control Panel is designed for working with AEMC PowerPad III Power Quality Analyzers,

More information

KNX Dimmer RGBW - User Manual

KNX Dimmer RGBW - User Manual KNX Dimmer RGBW - User Manual Item No.: LC-013-004 1. Product Description With the KNX Dimmer RGBW it is possible to control of RGBW, WW-CW LED or 4 independent channels with integrated KNX BCU. Simple

More information

Ultra 4K Tool Box. Version Release Note

Ultra 4K Tool Box. Version Release Note Ultra 4K Tool Box Version 2.1.43.0 Release Note This document summarises the enhancements introduced in Version 2.1 of the software for the Omnitek Ultra 4K Tool Box and related products. It also details

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ Products: AMIQ, SMIQ AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ The software AMIQ-K2 enables you to read, convert, and transfer various-format I/Q data files to AMIQ format. AMIQ-K2

More information

Using different reference quantities in ArtemiS SUITE

Using different reference quantities in ArtemiS SUITE 06/17 in ArtemiS SUITE ArtemiS SUITE allows you to perform sound analyses versus a number of different reference quantities. Many analyses are calculated and displayed versus time, such as Level vs. Time,

More information

GLog Users Manual.

GLog Users Manual. GLog Users Manual GLog is copyright 2000 Scott Technical Instruments It may be copied freely provided that it remains unmodified, and this manual is distributed with it. www.scottech.net Introduction GLog

More information

welcome to i-guide 09ROVI1204 User i-guide Manual R16.indd 3

welcome to i-guide 09ROVI1204 User i-guide Manual R16.indd 3 welcome to i-guide Introducing the interactive program guide from Rovi and your cable system. i-guide is intuitive, intelligent and inspiring. It unlocks a world of greater choice, convenience and control

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

Tebis application software

Tebis application software Tebis application software LED projector with quicklink radio infrared detector Electrical / Mechanical characteristics: see product user manual Product reference Product designation Application software

More information

Owner s manual Planner Radio Manager Online

Owner s manual Planner Radio Manager Online Owner s manual Planner Radio Manager Online V2.1 December 2014 Page 1 Contents Introduction... 5 Accessing the Planner... 5 1 - Planner... 6 Introduction... 6 1.1 The menu... 6 1.2 The Radionomy Player...

More information

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity Print Your Name Print Your Partners' Names Instructions August 31, 2016 Before lab, read

More information

Koester Performance Research Koester Performance Research Heidi Koester, Ph.D. Rich Simpson, Ph.D., ATP

Koester Performance Research Koester Performance Research Heidi Koester, Ph.D. Rich Simpson, Ph.D., ATP Scanning Wizard software for optimizing configuration of switch scanning systems Heidi Koester, Ph.D. hhk@kpronline.com, Ann Arbor, MI www.kpronline.com Rich Simpson, Ph.D., ATP rsimps04@nyit.edu New York

More information

EYE TRACKING DATA ANALYSIS TOOL

EYE TRACKING DATA ANALYSIS TOOL ETAnalysis Manual EYE TRACKING DATA ANALYSIS TOOL MANUAL VERSION 1.1 May, 2017 Argus Science LLC Email: argus@argusscience.com Table of Contents 1 INTRODUCTION... 5 1.1 BASIC FEATURES... 5 1.2 OPTIONAL

More information

(Skip to step 11 if you are already familiar with connecting to the Tribot)

(Skip to step 11 if you are already familiar with connecting to the Tribot) LEGO MINDSTORMS NXT Lab 5 Remember back in Lab 2 when the Tribot was commanded to drive in a specific pattern that had the shape of a bow tie? Specific commands were passed to the motors to command how

More information

TA Instruments Cement Analysis Software Getting Started Guide

TA Instruments Cement Analysis Software Getting Started Guide TA Instruments Cement Analysis Software Getting Started Guide Overview Cement Analysis software from TA Instruments is a standalone software application for running cement setting experiments and analyzing

More information

Stream Labs, JSC. Stream Logo SDI 2.0. User Manual

Stream Labs, JSC. Stream Logo SDI 2.0. User Manual Stream Labs, JSC. Stream Logo SDI 2.0 User Manual Nov. 2004 LOGO GENERATOR Stream Logo SDI v2.0 Stream Logo SDI v2.0 is designed to work with 8 and 10 bit serial component SDI input signal and 10-bit output

More information

PYROPTIX TM IMAGE PROCESSING SOFTWARE

PYROPTIX TM IMAGE PROCESSING SOFTWARE Innovative Technologies for Maximum Efficiency PYROPTIX TM IMAGE PROCESSING SOFTWARE V1.0 SOFTWARE GUIDE 2017 Enertechnix Inc. PyrOptix Image Processing Software v1.0 Section Index 1. Software Overview...

More information

Getting started with

Getting started with Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial premises OVERVIEW: The OWL Intuition-e electricity monitoring system comprises of three

More information

Part 1 Basic Operation

Part 1 Basic Operation This product is a designed for video surveillance video encode and record, it include H.264 video Compression, large HDD storage, network, embedded Linux operate system and other advanced electronic technology,

More information

Syntor X Flash Memory Module Revision C

Syntor X Flash Memory Module Revision C Syntor X Flash Memory Module Revision C The PIEXX SynXFlash memory module, along with the supplied PC software, replaces the original SyntorX code plugs and allows you to easily set modify and update your

More information

Measurements on Bluetooth Products using R&S CMU200/CBT and CMUgo/CBTgo

Measurements on Bluetooth Products using R&S CMU200/CBT and CMUgo/CBTgo R&S CMU200 (B53, K53, possibly B41), CMUgo, R&S CBT/CBT32 (B55, K55), CBTgo Measurements on Bluetooth Products using R&S CMU200/CBT and CMUgo/CBTgo This application note describes how Bluetooth products

More information

Table of content. Table of content Introduction Concepts Hardware setup...4

Table of content. Table of content Introduction Concepts Hardware setup...4 Table of content Table of content... 1 Introduction... 2 1. Concepts...3 2. Hardware setup...4 2.1. ArtNet, Nodes and Switches...4 2.2. e:cue butlers...5 2.3. Computer...5 3. Installation...6 4. LED Mapper

More information

Introduction to Probability Exercises

Introduction to Probability Exercises Introduction to Probability Exercises Look back to exercise 1 on page 368. In that one, you found that the probability of rolling a 6 on a twelve sided die was 1 12 (or, about 8%). Let s make sure that

More information

Getting Started with myevnts

Getting Started with myevnts Getting Started with myevnts Version 2.1.0 Document: Getting Started with myevnts Document Number: MYE-GSG-2.1.0 System Version: 2.1.0 Nielsen Media Research, Nielsen Homevideo Index, NSS, NTI and Pocketpiece

More information

Agilent Parallel Bit Error Ratio Tester. System Setup Examples

Agilent Parallel Bit Error Ratio Tester. System Setup Examples Agilent 81250 Parallel Bit Error Ratio Tester System Setup Examples S1 Important Notice This document contains propriety information that is protected by copyright. All rights are reserved. Neither the

More information

5024 WEIGHING TERMINAL

5024 WEIGHING TERMINAL Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 5024 WEIGHING TERMINAL Basic system with automatic dosing Applies to: Software: Document no.: STDLIM.140630.1v1

More information

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great LED Display Configuration Software SmartLCT User s Manual Software Version: V3.0 Rev3.0.0 NS110100239 Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter

More information

Software Quick Manual

Software Quick Manual XX113-30-00 Workstation and NVR Quick Manual Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error

More information

Digital TV. Connected. Amino Set Top Box Instructional Manual. Your pathway to the world. Digital TV powered by Celect Communications

Digital TV. Connected. Amino Set Top Box Instructional Manual. Your pathway to the world. Digital TV powered by Celect Communications Digital TV Amino Set Top Box Instructional Manual Digital TV powered by Celect Communications 328 W Main St New Auburn, WI 54757 Connected Your pathway to the world Phone (715)237-2605 Web: www.citizens-tel.net

More information

MAGIC THipPro. Signalling and Control with. Configuration Guide. using the example of a LAWO crystal mixing console. Version: March 26 th, 2018

MAGIC THipPro. Signalling and Control with. Configuration Guide. using the example of a LAWO crystal mixing console. Version: March 26 th, 2018 MAGIC THipPro Signalling and Control with Configuration Guide using the example of a LAWO crystal mixing console The configuration for MAGIC TH2plus and MAGIC TH6 is identical in most parts Version: 2.700

More information

TUTORIAL IGBT Loss Calculation in the Thermal Module

TUTORIAL IGBT Loss Calculation in the Thermal Module TUTORIAL IGBT Loss Calculation in the Thermal Module October 2016 1 In this tutorial, the process of calculating the IGBT power losses using PSIM s Thermal Module is described. As an illustration, Semikon

More information

Linrad On-Screen Controls K1JT

Linrad On-Screen Controls K1JT Linrad On-Screen Controls K1JT Main (Startup) Menu A = Weak signal CW B = Normal CW C = Meteor scatter CW D = SSB E = FM F = AM G = QRSS CW H = TX test I = Soundcard test mode J = Analog hardware tune

More information

Setting Up the Warp System File: Warp Theater Set-up.doc 25 MAY 04

Setting Up the Warp System File: Warp Theater Set-up.doc 25 MAY 04 Setting Up the Warp System File: Warp Theater Set-up.doc 25 MAY 04 Initial Assumptions: Theater geometry has been calculated and the screens have been marked with fiducial points that represent the limits

More information

For an alphabet, we can make do with just { s, 0, 1 }, in which for typographic simplicity, s stands for the blank space.

For an alphabet, we can make do with just { s, 0, 1 }, in which for typographic simplicity, s stands for the blank space. Problem 1 (A&B 1.1): =================== We get to specify a few things here that are left unstated to begin with. I assume that numbers refers to nonnegative integers. I assume that the input is guaranteed

More information

DDA-UG-E Rev E ISSUED: December 1999 ²

DDA-UG-E Rev E ISSUED: December 1999 ² 7LPHEDVH0RGHVDQG6HWXS 7LPHEDVH6DPSOLQJ0RGHV Depending on the timebase, you may choose from three sampling modes: Single-Shot, RIS (Random Interleaved Sampling), or Roll mode. Furthermore, for timebases

More information

APP USE USER MANUAL 2017 VERSION BASED ON WAVE TRACKING TECHNIQUE

APP USE USER MANUAL 2017 VERSION BASED ON WAVE TRACKING TECHNIQUE APP USE USER MANUAL 2017 VERSION BASED ON WAVE TRACKING TECHNIQUE All rights reserved All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in

More information

CORIOmax Resolution Editor Programming Guide 2015/03/04

CORIOmax Resolution Editor Programming Guide 2015/03/04 CORIOmax Resolution Editor Programming Guide 2015/03/04 Document Information General Information: Title CORIOmax Resolution Editor Programming Guide Author Version 2.1 Brief Version Control: Version Amendments

More information

Cisco Spectrum Expert Software Overview

Cisco Spectrum Expert Software Overview CHAPTER 5 If your computer has an 802.11 interface, it should be enabled in order to detect Wi-Fi devices. If you are connected to an AP or ad-hoc network through the 802.11 interface, you will occasionally

More information

Overview. Project Shutdown Schedule

Overview. Project Shutdown Schedule Overview This handbook and the accompanying databases were created by the WGBH Media Library and Archives and are offered to the production community to assist you as you move through the different phases

More information

Chapter 40: MIDI Tool

Chapter 40: MIDI Tool MIDI Tool 40-1 40: MIDI Tool MIDI Tool What it does This tool lets you edit the actual MIDI data that Finale stores with your music key velocities (how hard each note was struck), Start and Stop Times

More information

BrainMaster tm System Type 2E Module & BMT Software for Windows tm. Display Screens for Master.exe

BrainMaster tm System Type 2E Module & BMT Software for Windows tm. Display Screens for Master.exe BrainMaster tm System Type 2E Module & BMT Software for Windows tm Display Screens for Master.exe 1995-2004 BrainMaster Technologies, Inc., All Rights Reserved BrainMaster and From the Decade of the Brain

More information

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices Audio Converters ABSTRACT This application note describes the features, operating procedures and control capabilities of a

More information

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters Written By: Colin Langridge Issue: Draft Date: 03 rd July 2008 1 Date: 29 th July 2008 2 Date: 20 th August 2008 3 Date: 02 nd

More information

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool For the SIA Applications of Propagation Delay & Skew tool Determine signal propagation delay time Detect skewing between channels on rising or falling edges Create histograms of different edge relationships

More information

Setting up the app. Press the Setting button (gear symbol) on the upper screen to go setup app. Before you

Setting up the app. Press the Setting button (gear symbol) on the upper screen to go setup app. Before you Setting up the app Press the Setting button (gear symbol) on the upper screen to go setup app. Before you simulate the air settings, be sure to configure the app s setting properly. Language Please choose

More information

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL DATA ACQUISITION SYSTEM V.15.4 INSTRUCTION MANUAL Timberline Instruments, LLC 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx:

More information

LED Effects Technology for professionals.

LED Effects Technology for professionals. LED Effects Technology for professionals. User Guide Pixel-Gate Introduction Video inputs ArtNet outputs 4 System Architecture Cabling Example Installation Menu Basis operation Detailed operation Changing

More information

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России) 127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) 322-99-34 +7 (800) 200-74-93 (бесплатно на территории России) E-mail: info@awt.ru, web:www.awt.ru Contents 1 Introduction...2

More information