ATT AN TENG TESTING R& TTE TEST REPORT. For Electric Skateboard Surfwheel. Test Report Number: ATT RT

Size: px
Start display at page:

Download "ATT AN TENG TESTING R& TTE TEST REPORT. For Electric Skateboard Surfwheel. Test Report Number: ATT RT"

Transcription

1 TT N TENG TESTING R& TTE TEST REPORT For Electric Skateboard Surfwheel R1 Trademark: Surfwheel Test Report Number: TT RT Issued Date: June 02, 2016 Issued for: Koofy Development Limited Unit 220 2/F, Enterprise Place, NO.5 Science Park West venue, Science Park, Shatin, N.T., HK TEL: FX: Note: This report shall not be reproduced except in full, without the written approval of Shenzhen n-teng Testing Service Co., Ltd. This document may be altered or revised by Shenzhen n-teng Testing Service Co., Ltd. personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample.

2 TT N TENG TESTING 1 GENERL INFORMTION Shenzhen n-teng Testing Service Co., Ltd Report No.: TT RT pplicant Koofy Development Limited ddress Unit 220, 2/F, Enterprise Place, NO.5 Science Park West venue, Science Park, Shatin, N.T., HK Manufacture Huizhou Tianchang Industrial Co. Ltd. ddress No.2, Xingde & Xingye Rd, Dongjiang Hi-tech Zone, Zhongkai Hi-tech Zone, Huizhou, Guangdong, China Equipment under Test (EUT) Name: Model No.: EUT Power Supply: Standards: ITest Result: Electric Skateboard Surfwheel R 1 DC 59V (Recharge Voltage: DC 67.2V, 1.5) ETSI EN : 2002 V1.4.1, ETSI EN :2008 V1.8.1 I PSS In the configuration tested, the EUT detailed in this report complied with the standards specified above. refer to section 2 of this report for further details. Please The other tests (e.g. Low Voltage Directive 2014/30/EU) required in R&TIE Directive2014/53/EU were not included in the report, only part tests related to RF were performed and reported in this report. Hence to clarify compliance with R&TTE directive 99/5/EC shall comply with the other essential required tests additionally. I Tested By: t MI(/& ~'I'f- /~ Nico Liang Date: ~J~u"n~e~Oul~._2~Ol~6~ Check By: ~~~~~~~~ Date : ---IJll,luwnwei..lil ,...21ir.10"'1u.61..-_ dd: Room1502, Liutang Building, Baomin 2nd Road, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China. Page 2 of 23

3 2 Test Summary Shenzhen n-teng Testing Service Co., Ltd Electromagnetic Compatibility (EMC) Part The EUT belong to Type I in table 1 and class 3 in table 3 (refer to nnex B) of EN :2002. Test Test Requirement Test Method Class / Severity Remark Result Radiated Emission, 30MHz to 6 GHz EN :2002 V clause 7.1 EN : 2008 V1.8.1.clause 8.2, EN55016 Class B Table 3, 4 Test Rx only PSS Conducted emission (150K to 30MHz) EN :2002 V clause 7.2 EN : 2008 V1.8.1.clause 8.3/ 8.4/ 8.7 EN Class B Test both Rx & Tx together. (worst case) N/ Electrostatic Discharge EN :2002 V clause 7.2 EN /9.3 EN kV, Contact 8kV. ir Test Tx & Rx together PSS Radiated Immunity, 80MHz to 1GHz & 1.4GHz to 2.7GHz EN :2002 V clause 7.2 EN /9.2 EN V/m, 80%, 1KHz,.M. Test Tx & Rx together PSS EFT (Electrical Fast Transients) on C EN :2002 V clause 7.2 EN /9.4 EN Table 3 row 4 Test Tx & Rx together N/ Surge Immunity on C EN :2002 V clause 7.2 EN /9.8 EN Table 3 row 8 Test Tx & Rx together N/ Injected Currents 150kHz to 80MHz EN :2002 V clause 7.2 EN /9.5 EN Table 3 row 5 Test Tx & Rx together N/ Voltage Dips and Interruptions on C EN :2002 V clause 7.2 EN /9.7 EN Table 3 row 7 Test Tx & Rx together N/ Tx: In this whole report Tx (or tx) means Transmitter. Rx: In this whole report Rx (or rx) means Receiver. Page 3 of 23

4 3 Contents Page 1 GENERL INFORMTION TEST SUMMRY CONTENTS GENERL INFORMTION CLIENT INFORMTION DETILS OF E.U.T DESCRIPTION OF SUPPORT UNITS STNDRDS PPLICBLE FOR TESTING TEST LOCTION DEVITION FROM STNDRDS OTHER INFORMTION REQUESTED BY THE CUSTOMER MONITORING OF EUT FOR THE IMMUNITY TEST MODEL DIFFERENCE EMC REQUIREMENTS SPECIFICTION IN EN EMI (EMISSION) Radiated Emission Conducted Emission Harmonics Test Results Flicker Test Results IMMUNITY ESD Radiated Immunity Electrical Fast Transients (EFT) RF Common Mode 0.15MHz to 80MHz PPENDIX : INSTRUMENTS USED DURING TEST EUT PHOTOGRPHS Page 4 of 23

5 4 General Information 4.1 Client Information pplicant: ddress of pplicant: 4.2 Details of E.U.T Koofy Development Limited Unit 220, 2/F, Enterprise Place, No.5 Science Park West venue, Science Park, Shatin, N.T., HK EUT Power Supply: DC 59V (Recharge Voltage: DC 67.2V,1.5) 4.3 Description of Support Units The EUT has been tested as an independent unit. 4.4 Standards pplicable for Testing The customer requested (R&TTE) EMC part tests for R/C CR. The standards used were EN V1.4.1 ( ) Table 1 : Tests Carried Out Under EN V1.4.1 ( ) EMI TEST ITEM TEST METHOD Clause 7.1 Radiated Emission EN : 2008 V1.8.1.clause 8.2, EN55016 Conducted Emission EN : 2008 V1.8.1.clause 8.3/ 8.4/ 8.7, EN55022 Harmonic Current EN : 2008 V1.8.1.clause 8.5 EN Voltage Fluctuation & Flicker EN : 2008 V1.8.1.clause 8.6 EN EMS TEST ITEM TEST METHOD Clause 7.2 RF EM fields (RI) EN : 2008 V1.8.1.clause 9.2, EN Electrostatic Discharge (ESD) EN : 2008 V clause 9.3, EN Fast transients (EFT) EN : 2008 V1.8.1.clause 9.4, EN : RF Common Mode (CI) EN : 2008 V1.8.1.clause 9.5, EN Transient & Surge in Vehicular EN : 2008 V1.8.1.clause 9.6, ISO7637-1/-2 Voltage dips & Interruption EN : 2008 V1.8.1.clause 9.7, EN Surge EN : 2008 V1.8.1.clause 9.8, EN : Indicates that the test was not applicable, since the EUT is powered by DC input. : Indicates that the test was applicable. Page 5 of 23

6 4.5 Test Location ll tests were performed at: NTEK Testing Technology Co., Ltd. ddress: Fenda Science Park, Sanwei Community, Xixiang Street, Bao'an District, Shenzhen, China 4.6 Deviation from Standards None. 4.7 Other Information Requested by the Customer None. 4.8 Monitoring of EUT for the Immunity Test Visual: Monitored the work status of the EUT. udio: Monitored the sound of the EUT. 4.9 Model difference Page 6 of 23

7 5 EMC Requirements Specification in EN Type of SRD Equipment in EN , sub clause 4.1 table 1 Equipment Type I II III Technical nature of the primary function Transfer of messages (digital or analogue signals) Transfer of audio (speech or music) Others Classification of SRD Equipment in EN , sub clause 6.1 table 3 Class of SRD Equipment Risk assessment of Rx performance Highly reliable SRD communication media; e.g. serving human life inherent system (may result in a physical risk to a person) Medium reliable SRD communication media e.g. causing inconvenience to persons, which cannot simply overcome by other means Standard reliable SRD communication media e.g. causing inconvenience to persons, which can simply overcome by other means Remark: The EUT belong to Type I, class 3. Page 7 of 23

8 5.1 EMI (Emission) Radiated Emission Test Method: EUT Operation: EN clause (EN ) Running(Test both Rx & Tx together). mbient: Temp.: 25 C Humid.: 45% Press.: 1050 mbar Status: Compliance test in keeping running mode. Receive setup: Frequency range (MHz) Detector RBW VBW Quasi-peak 120KHz 300KHz bove 1000 Peak 1MHz 3MHz Test Limit Frequency Limit(3m) Remark Test Procedure: 30MHz-230MHz 40dBuv/m QP value 230MHz-1GHz 47dBuv/m QP value 1GHz-3GHz 3GHz-6GHz 50dBuv/m 70dBuv/m 54dBuv/m 74dBuv/m verage value PK value verage value PK value 1. The EUT is placed on a turntable, which is 0.8m above ground plane. 2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission level. 3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the maximum emissions. 4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance. 5. nd also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. 6. Repeat above procedures until the measurements for all frequencies are complete. Equipment Used: Please refer to the section 6. Page 8 of 23

9 Test Configuration: Below 1GHz bove 1GHz Page 9 of 23

10 Measurement Record Uncertainty: 6dB Rx running mode below 1GHz Cable ntenna Preamp Read Over Frequency Level Limit Line Loss Factor Factor Level Limit (MHz) (dbuv/m) (dbuv/m) (db) (db/m) (db) (dbuv) (db) Polarity Vertical Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Rx running mode above 1GHz Peak measurement Cable ntenna Preamp Read Limit Over Frequency Level Loss Factor Factor Level Line Limit (MHz) (dbuv/m) (db) (db/m) (db) (dbuv) (dbuv/m) (db) Polarity Vertical Vertical Vertical Horizontal Horizontal Horizontal verage measurement Page 10 of 23

11 Frequency (MHz) Cable Loss (db) ntenna Factor (db/m) Preamp Factor (db) Read Level (dbuv) Level (dbuv/m) Limit Line (dbuv/m) Over Limit (db) Polarity Vertical Vertical Vertical Horizontal Horizontal Horizontal Remark: The EUT was tested at 3m in field chamber Conducted Emission Test Method: EN clause (EN 55022) Detector: Peak for pre-scan (9kHz Resolution Bandwidth) Quasi-Peak if maximised peak within 6dB of Quasi-Peak limit EUT Operation: Running(Test both Rx & Tx together). mbient: Temp.: 25 C, Humid.: 63% Press.: 1050 mbar Status: Test Procedure: Equipment Used: Compliance test in keeping running mode. Scan from 0.15M to 30MHz, find the maximum radiation frequency to measure. Refer to section 5 for details. Test Configuration: Test Results N/ Page 11 of 23

12 5.1.3 Harmonics Test Results Test Requirement: EN : EN Test Method: N/: See Remark Below Remark: There is no need for Harmonics test to be performed on this product (rated power is less than 75W) in accordance with EN For further details, please refer to Clause 7, Note 1 of EN which states:- For the following categories of equipment limits are not specified in this edition of the standard. Note 1: Equipment with a rated power of 75W or less, other than lighting equipment Flicker Test Results Test Requirement: EN : EN Test Method: N/: See remark below Remark: There is no need for Flicker test to be performed on this product in accordance with EN For further details, please refer to Clause 6.1 of EN which states:- Tests need not be made on equipment which is unlikely to produce significant voltage fluctuations or flicker. It may be necessary to determine, by examination of the circuit diagram and the specification of the equipment and by a short function test, whether significant voltage fluctuations or flicker are likely to be produced. Page 12 of 23

13 5.2 Immunity Performance Criteria of EN , sub clause 6.3 table 4. Class 1 SRD Equipment Criteria During Test fter Test B Operated as intended, Operated as intended, No loss of function, No loss of function, For equipment Type II the communication link shall For equipment Type II the minimum be maintained. performance shall be 12dB SIND, No Degradation of performance, No unintentional responses. No loss of data or user programmable functions May be loss of function (one or more) Operated as intended, No unintentional responses Loss functions shall be self- recoverable, No Degradation of performance, No loss of data or user programmable functions Class 2 SRD Equipment Criteria During Test fter Test B Operated as intended, No loss of function, For equipment Type II the minimum performance shall be 6dB SIND, No unintentional responses. May be loss of function (one or more), No unintentional responses Operated as intended, No loss of function, For equipment Type II the communication link shall be maintained. No Degradation of performance, No loss of data or user programmable functions Operate as intended, Loss functions shall be self- recoverable, No Degradation of performance, No loss of data or user programmable functions Class 3 SRD Equipment Criteria During Test fter Test & B May be loss of function (one or more), No unintentional respond. Operate as intended, for equipment Type II the communication link may be lost, but shall be recoverable by user. No Degradation of performance. Loss functions shall be self- recoverable. Page 13 of 23

14 Remark: The EUT belonged to class 3. Shenzhen n-teng Testing Service Co., Ltd Page 14 of 23

15 5.2.1 ESD Test Method: EN clause (EN : :1998+2: 2001) EUT Operation: Running(Test both Rx & Tx together). mbient: Temp.: 25 C Humid.: 63% Press.: 1050 mbar Status: 1) Kept Tx & Rx on mode, 2) Kept Tx & Rx idle mode. Test both Rx & Tx together. Test Procedure: Compliance test was performed in mode 1), 2) Equipment Used: Please refer to the section Test Results Direct pplication Test Results Test points: Direct pplication 1. ll insulated enclosure and seams. 2. ll accessible metal parts of the enclosure. Test Results Discharge Level (kv) Pulse No. Test Point Contact Discharge ir Discharge 2, 4, 8 10 for every level 1 N/ 2, 4 10 for every level 2 N/ Indirect pplication Test Results Test points: Indirect pplication for Tx 1. ll sides. Discharge Level (kv) Pulse No. Test Point Horizontal Coupling Test Results Vertical Coupling 2, 4 10 for every level 1 Indirect pplication for Rx Test Results Discharge Level (kv) Pulse No. Test Point Horizontal Coupling Vertical Coupling 2, 4 10 for every level 1 Results : No degradation in the performance of the EUT was observed. No unintentional transmissions were observed. N/: Not applicable (not required by Standard or floor mounted EUT). Page 15 of 23

16 5.2.2 Radiated Immunity Test Method: EUT Operation: EN clause (EN :2006+1:2008) Running(Test both Rx & Tx together). mbient: Temp.: 25 C Humid.: 45% Press.:1050mBar Status: 1) Kept Tx & Rx on mode, 2) Kept Tx & Rx idle mode. Test both Rx & Tx together. Test Procedure: Compliance test were performed in mode 1), 2) Equipment Used: Please refer to the section Test Results Frequency Level Modulation EUT Face ntenna Polaxis V Front H Result / Observations Back V H 80MHz-1GHz, 1.4GHz to 2.7G 3V/m 1kHz, 80% mp. Mod, 1% increment Dwell time:3seconds Left Right V H V H Top V H Under V H Remarks: : No degradation in the performance of the E.U.T. was observed. No unintentional transmissions were observed. Page 16 of 23

17 5.2.3 Electrical Fast Transients (EFT) Test Method: EN clause (EN :2004) Test Level: Polarity: Repetition Frequency: Burst Duration: Test Duration: EUT Operation: 0.5, 1.0kV on C Positive & Negative 5kHz 300ms 2 minute per level & polarity Running(Test both Rx & Tx together). mbient: Temp.: 25 C Humid.: 45% Press.: 1050mBar Status: 1) Keep the RX unit in running mode. 2) Keep the RX unit in idle mode. Test both Rx & Tx together. Test Procedure: Compliance test were performed in mode 1), 2) Equipment Used: Refer to section 5 for details Test Results Lead under Test Level ( kv) Coupling Direct/Clamp EUT operating mode Observations (Performance Criterion) Live 1.0 Direct ll mode No loss of performance was observed () Neutral 1.0 Direct ll mode () Live, Neutral 1.0 Direct ll mode () Page 17 of 23

18 5.2.4 RF Common Mode 0.15MHz to 80MHz Test Method: EN clause (EN :2007) Test level: 3V rms on C Ports (unmodulated emf into 150 ) Modulation: 80%, 1kHz mplitude Modulation EUT Operation: Running(Test both Rx & Tx together). mbient: Temp.:25 C Humid.:63% Press.:1050 mbar Status: 1) Keep the RX unit in running mode. 2) Keep the RX unit in idle mode. Test both Rx & Tx together. Test Procedure: Equipment Used: Compliance test was performed in the abovemodes Refer to section 5 for details Test Results Frequency Line Test Level Modulation Step Size Dwell Time Observation (Performance Criterion) 150kHz to 80MHz 3 Wire C Supply Cable 3Vrm s 80%, 1kHz mp. Mod. 1% 2S No Loss of Function () Page 18 of 23

19 6 ppendix : Instruments Used during Test RE in Chamber Item Test Equipment Manufacturer Model No. Inventory No. Cal.Date (dd-mm-yy) Cal.Due date (dd-mm-yy) 1 3m Semi-nechoic Chamber ETS-LINDGREN N/ SEL EMI Test Receiver Rohde & Schwarz ESIB26 SEL EMI Test software UDIX E3 SEL0050 N/ N/ 4 Coaxial cable SGS N/ SEL BiConiLog ntenna ( MHz) ETS-LINDGREN 3142C SEL Pre-amplifier ( MHz) Double-ridged horn (1-18GHz) Horn ntenna (18-26GHz) Pre-amplifier (18-26GHz) gilent Technologies 8447D SEL ETS-LINDGREN 3117 SEL ETS-LINDGREN 3160 SEL Rohde & Schwarz FS P-44 SEL Band filter mindeon SEL ctive.loop ntenna Beijing Daze ZN30900 SEL Conducted Emission Item Test Equipment Manufacturer Model No. Inventory No. Cal.Date (dd-mm-yy) Cal.Due date (dd-mm-yy) 1 Shielding Room ZhongYu Electron GB-88 SEL0042 N/ N/ 2 LISN ETS-LINDGREN 3816/2 SEL Line ISN Fischer Custom Communications FCC-TLISN-T8-02 EMC Inc. 4 4 Line ISN Fischer Custom Communications FCC-TLISN-T4-02 EMC Inc. 5 2 Line ISN Fischer Custom Communications FCC-TLISN-T2-02 EMC Inc. 6 EMI Test Receiver Rohde & Schwarz ESCI SEL Page 19 of 23

20 7 Coaxial Cable SGS N/ SEL ESD Item Test Equipment Manufacturer Model No. Inventory Cal.Date Cal.Due date No. (dd-mm-yy) (dd-mm-yy) 1 ESD Simulator Thermo MZ-15/EC SEL ESD Simulator SCHFFNER NSG 438 SEL ESD Ground Plane SGS(3m*3m) N/ SEL0004 N/ N/ Radiated Immunity Item Test Equipment Manufacturer Model No. Inventory No. Cal.Date (dd-mm-yy) Cal.Due date (dd-mm-yy) 1 3m Semi-nechoic Chamber ETS-LINDGREN N/ SEL Signal Generator Rohde & Schwarz SML03 SEL RF mplifier 30M-1GHz mplifier Research 250W1000 SEL RF mplifier GHz mplifier Research 60S1G3 SEL Power Meter Rohde & Schwarz NRVD SEL Power Sensor Rohde & Schwarz URV5-Z2 SEL Power Sensor Rohde & Schwarz URV5-Z2 SEL Software EMC32 Rohde & Schwarz EMC32-S SEL0082 N/ N/ 9 Log-periodic ntenna mplifier Research T1080 SEL0073 N/ N/ 10 ntenna Tripod mplifier Research TP1000 SEL0074 N/ N/ 11 High Gain Horn ntenna (0.8-5GHz) mplifier Research T4002 SEL0075 N/ N/ EFT, Surge, Voltage dips and Interruption, Power-frequency Magnetic Field Item Test Equipment Manufacturer EMC Immunity Test System ProPLUS Capacitive Clamp MGNETIC FIELD IMMUNITY LOOP Thermo ELECTRON Thermo ELECTRON Model No. Inventory No. Cal.Date (dd-mm-yy) Cal.Due date (dd-mm-yy) EMCPro Plus SEL N/ SEL0008 N/ N/ FCC F /9/10-L-1M SEL Page 20 of 23

21 7 EUT PHOTOGRPHS Shenzhen n-teng Testing Service Co., Ltd Photo 1 View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal Photo 2 View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal Page 21 of 23

22 Photo 3 View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal Photo 4 View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal Page 22 of 23

23 Photo 5 Shenzhen n-teng Testing Service Co., Ltd View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal --END.-- Page 23 of 23

R&TTE EMC TEST REPORT

R&TTE EMC TEST REPORT No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 Email: sgs_internet_operations@sgs.com Application

More information

EMC REPORT. Shenzhen Sunchip Technology Co., Ltd. * In the configuration tested, the EUT complied with the standards specified above.

EMC REPORT. Shenzhen Sunchip Technology Co., Ltd. * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS16000346E01 EMC REPORT Applicant: Shenzhen Sunchip Technology Co., Ltd Address of Applicant: 201-301, Building A4, No. 90, Dayang Road, FuYong town, Bao'an District, Shenzhen, China Equipment

More information

FCC REPORT. SZEM CR Monument Labs, Inc. Qingyuan Gadmei Electronics Technology Co., Ltd. Monument Photo Management Device

FCC REPORT. SZEM CR Monument Labs, Inc. Qingyuan Gadmei Electronics Technology Co., Ltd. Monument Photo Management Device No. Workshop, M-, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 5857 Telephone: +86 () 755 26 253 Fax: +86 () 755 267 594 Email: ee.shenzhen@sgs.com Page: of 8 Cover page pplication

More information

FCC Report. Beijing Visual World Technology Co.,Ltd.

FCC Report. Beijing Visual World Technology Co.,Ltd. FCC Report Report No.: GTS201703000097F01 Applicant: Beijing Visual World Technology Co.,Ltd. Address of Applicant: 15th Floor and 17th Floor 1701-10A, Building 3, No. 10, Jiuxianqiao Road Jia, Chaoyang

More information

TEST REPORT. iphone Hi-Fi Audio cable Adapter with Lightning female connector Model No.:

TEST REPORT. iphone Hi-Fi Audio cable Adapter with Lightning female connector Model No.: No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 Email: ee.shenzhen@sgs.com Application No.:

More information

FCC Report (WIFI) Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town Business Park LiShan Road, NanShan, Shenzhen, Guangdong, China

FCC Report (WIFI) Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town Business Park LiShan Road, NanShan, Shenzhen, Guangdong, China FCC Report (WIFI) Applicant: Address of Applicant: Manufacturer/y: Address of Manufacturer/y: Equipment Under Test (EUT) Product Name: Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town

More information

FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS

FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS Page 1 of 22 FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS Prepared for Address Prepared By Address : Aeon Labs LLC. : 121 Buckingham drive, unit36 santa claras

More information

Testing. Maker Works. Applicant: Model No.: FCC ID: Jun., May to 16. Date of Test: PASS* Test Result: Signature: Authorized. this report.

Testing. Maker Works. Applicant: Model No.: FCC ID: Jun., May to 16. Date of Test: PASS* Test Result: Signature: Authorized. this report. 1 Cover Page Shenzhen Zhongjian Nanfang Testing Co., Ltd. FCC REPORT Applicant: Address of Applicant: Maker Works Technology INC Building C3, Floor 4th, Zhiyuan, Xili, Nanshan District, ShenZhen 518057

More information

FCC REPORT Q6WBT * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT Q6WBT * In the configuration tested, the EUT complied with the standards specified above. 1 Cover Page Report No: CCIS12110026101 FCC REPORT Applicant: Address of Applicant: Equipment Under Test (EUT) GUANGDONG STEELMATE SECURITY CO., LTD Renan Street, Dong fu Road, Dongfeng Town,Zhongshan,

More information

Page: 1 of 19 EMC TEST REPORT EN55024:1998+A2:2003

Page: 1 of 19 EMC TEST REPORT EN55024:1998+A2:2003 Page: 1 of 19 EMC TEST REPORT Reference No. Applicant : WT05110894 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Card reader Model No : USB2.0A LL-in-1 Standards : EN55022:1998+A2:2003

More information

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCIS15010007003 1 Cover Page FCC REPORT Applicant: Address of Applicant: Interglobe Connection Corp 7500 NW 25 th Street 112 Miami, Florida 33122 USA Equipment Under Test (EUT) Product Name:

More information

FCC Report (WIFI) Red Bear Company Limited. RedBear IoT phat 2ABXJ-PHAT-IOT

FCC Report (WIFI) Red Bear Company Limited. RedBear IoT phat 2ABXJ-PHAT-IOT Report No.: GTS201607000065E01 FCC Report (WIFI) Applicant: Red Bear Company ed Address of Applicant: 1711 Block B, Wah Luen Industrial Centre, 15-21 Wong Chuk Yeung Street, Fo Tan, Hong Kong Equipment

More information

Sensoray. Model 819. Tests Conducted by: ElectroMagnetic Investigations, LLC. May 10, 2013

Sensoray. Model 819. Tests Conducted by: ElectroMagnetic Investigations, LLC. May 10, 2013 European Union (EU) Council Directive 2004/108/EC Electromagnetic Compatibility (EMC) and FCC Part 15 Subpart B Class B Test Report for Information Technology Equipment Sensoray Model 819 May 10, 2013

More information

FCC Report (WIFI) Shenzhen SDMC Technology Co., Ltd 2AFC2-STB-1HD. * In the configuration tested, the EUT complied with the standards specified above.

FCC Report (WIFI) Shenzhen SDMC Technology Co., Ltd 2AFC2-STB-1HD. * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTSE15080158301 FCC Report (WIFI) Applicant: Shenzhen SDMC Technology Co., Ltd Address of Applicant: 7/F, W2-A Bld, Gaoxin S. Av. 4, Hi-tech Park, Nanshan, Shenzhen, China Equipment Under Test

More information

FCC Part 15 Subpart B Test Report. FCC PART 15 Subpart B Class B: 2014

FCC Part 15 Subpart B Test Report. FCC PART 15 Subpart B Class B: 2014 Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 FCC Part 15 Subpart B Test Report FCC PART 15 Subpart B Class B: 2014 Report Reference No...: CTL1408272147-F

More information

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCISE8572 Cover Page FCC REPORT (Bluetooth) pplicant: ddress of pplicant: Equipment Under Test (EUT) GROUPSFIT 8/84 route de la Libération 7734 PONTULT COMBULT France Product Name: Model No.:

More information

FCC TEST REPORT For. ETI Solid State Lighting (Zhuhai) Ltd. LED downlight Model No.: XX

FCC TEST REPORT For. ETI Solid State Lighting (Zhuhai) Ltd. LED downlight Model No.: XX Page 1 of 24 FCC TEST REPORT For ETI Solid State Lighting (Zhuhai) Ltd LED downlight Model No.: 531931XX Prepared for Address Prepared by Address : ETI Solid State Lighting (Zhuhai) Ltd : No.1, Zhongzhu

More information

TABLE OF CONTENTS 1. GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY

TABLE OF CONTENTS 1. GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY FCC Rule(s): FCC Part 15B Measurement and Test Report Product Description: Tested Model: Report No.: For GlobTek, Inc. 186 Veterans Dr. Northvale, NJ 07647 USA FCC Part 15 Subpart B X-PLORE 8000 STANDARD

More information

FCC Test Report (Bluetooth)

FCC Test Report (Bluetooth) Report No.: T479F Page: of 52 FCC Test Report (Bluetooth) FCC ID : 8IVOOMBOX-ONGO pplicant : Shenzhen DIVOOM Technology Co., Ltd. 3, 2nd Floor, Block, Zhengxing Building, No. 33 Taizi Road, Shekou, Nanshan

More information

STC (Dongguan) Company Limited EC VERIFICATION OF COMPLIANCE EMC-D163584VOC

STC (Dongguan) Company Limited EC VERIFICATION OF COMPLIANCE EMC-D163584VOC EC VERIFICATION OF COMPLIANCE Reference Number: Applicant: EMC-D16584VOC Zhuhai Zhi Li Battery Co., Ltd. 7/F., Building 10, Xiang Zhou North Industry Park, Zhuhai, GD 519002, China Description: Zinc Air

More information

Report On. FCC Testing of the Pace Plc 16x4 Hybrid Gateway Cable Set Top Box COMMERCIAL-IN-CONFIDENCE

Report On. FCC Testing of the Pace Plc 16x4 Hybrid Gateway Cable Set Top Box COMMERCIAL-IN-CONFIDENCE Report On FCC Testing of the Pace Plc 16x4 Hybrid Gateway Cable Set Top Box Document 75926325 Report 01 Issue 1 April 2014 TÜV SÜD Product Service, Octagon House, Concorde Way, Segensworth North, Fareham,

More information

FCC PART MEASUREMENT AND TEST REPORT FOR. DongGuan City FLYSKY Remote Model Co., Ltd.

FCC PART MEASUREMENT AND TEST REPORT FOR. DongGuan City FLYSKY Remote Model Co., Ltd. FCC PART 15.249 MEASUREMENT AND TEST REPORT FOR DongGuan City FLYSKY Remote Model Co., Ltd. No.41 Road West, BanHu Village, HuangJiang Town, DongGuan City, GuangDong Porvince, China FCC ID: VPOFLYSKY002

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 IC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00095-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China TEST

More information

Test Report. Product Name: Access Point Model No.: MS-6809 FCC ID: DoC

Test Report. Product Name: Access Point Model No.: MS-6809 FCC ID: DoC Test Report Product Name: Access Point Model No.: MS-6809 FCC ID: DoC Applicant : MICRO-STAR INT L Co., LTD Address : No 69, Li-De st., Jung-He City, Taipei Hsien, Taiwan, R.O.C Date of Receipt : June

More information

FCC PART 15B, CLASS B TEST REPORT. Autel Intelligent Tech. Corp., Ltd.

FCC PART 15B, CLASS B TEST REPORT. Autel Intelligent Tech. Corp., Ltd. FCC PART 15B, CLASS B TEST REPORT For Autel Intelligent Tech. Corp., Ltd. 6th - 10th Floor, Bldg. B1, Zhiyuan, Xueyuan Rd., Xili, Nanshan Shenzhen China FCC ID: WQ8MAXISYSMY906 Report Type: Original Report

More information

FCC ID: IMK-ILCISA EMI TEST REPORT

FCC ID: IMK-ILCISA EMI TEST REPORT 15.247 Certification FCC ID: IMK-ILCISA EMI TEST REPORT On SYMPHONY ISA Card Prepared for Proxim 295 N. Bernardo Ave Mountain View, CA 94043 Tel: (650)960-1630 Fax: (650)960-0332 Prepared by Electronic

More information

Sunlight Supply, Inc.

Sunlight Supply, Inc. FCC Part 18 Subpart C Consumer For RF Lighting Equipment Electromagnetic Compatibility Test Report Sunlight Supply, Inc. Etelligent Compatible Ballast - olt July 19, 2017 Tests Conducted by:, LLC 20811

More information

Test Report. Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 )

Test Report. Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 ) Test Report Applicant: Product Name: Brand Name: Jetway Information Co.,Ltd Motherboard/Barebone N/A Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for

More information

CONTENTS 1. GENERAL INFORMATION INTRODUCTION PRODUCT INFORMATION DESCRIPTION OF TESTS CHANNEL BANDWIDTH...

CONTENTS 1. GENERAL INFORMATION INTRODUCTION PRODUCT INFORMATION DESCRIPTION OF TESTS CHANNEL BANDWIDTH... Test Report Number : GETEC-E3-09-083 Page 2 / 33 CONTENTS. GENERAL INFORMATION...4 2. INTRODUCTION...5 3. PRODUCT INFORMATION...6 3. DESCRIPTION OF EUT...6 3.2 SUPPORT EQUIPMENT / CABLES USED...7 3.3 MODIFICATION

More information

FCC PART TEST REPORT. HHC Changzhou Corp.

FCC PART TEST REPORT. HHC Changzhou Corp. FCC PART 15.249 TEST REPORT For HHC Changzhou Corp. No 61, Xinggang Road, Zhonglou District, Changzhou, Jiangsu, China, 213023 FCC ID: 2AEQWCB20HHC011 Report Type: Original Report Product Type: Control

More information

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd.

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd. FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT For Tritech Technology Ltd. Unit 8B,Chung pont Commercial Building No.300 Hennessy Road, Wanchai, HongKong Model: 0-545-24967-8, 0-545-24986-4 Report Type:

More information

Test Report. Applicant Address. : WALTOP International Corp. : 6F,No.19-1 Industry E.Rd.IV,Hsinchu Science Park,Hsin-Chu 30077,Taiwan,R.O.C.

Test Report. Applicant Address. : WALTOP International Corp. : 6F,No.19-1 Industry E.Rd.IV,Hsinchu Science Park,Hsin-Chu 30077,Taiwan,R.O.C. Test Report Product Name : Tablet: Wireless Tablet X86/X86; Dongle: Wireless Tablet Receiver X86/X86 Model No. : Tablet: RCK-T7, RCK-T7S; Dongle: RCK-T7R, RCK-T7RS FCC ID. : Tablet: UBBRCKT7, Dongle: UBBRCKT7R

More information

Global United Technology Services Co., Ltd. TEST REPORT. Bentel Sistem SRL. HEGEL STREET NO.1, Cluj-Napoca, Romania Equipment Under Test (EUT)

Global United Technology Services Co., Ltd. TEST REPORT. Bentel Sistem SRL. HEGEL STREET NO.1, Cluj-Napoca, Romania Equipment Under Test (EUT) Report No.: GTSE15030028301 TEST REPORT Applicant: Address of Applicant: Bentel Sistem SRL HEGEL STREET NO.1, 400448 Cluj-Napoca, Romania Equipment Under Test (EUT) Product Name: Model No.: Trade Mark:

More information

CHAO WEI ELECTRONICS CO., LTD. FCC REPORT CHAO WEI ELECTRONICS CO., LTD.

CHAO WEI ELECTRONICS CO., LTD. FCC REPORT CHAO WEI ELECTRONICS CO., LTD. CHAO WEI ELECTRONICS CO., LTD. FCC REPORT Prepared For : CHAO WEI ELECTRONICS CO., LTD. No.8, Xianglong Road, Xiagang, Changantown, Dongguan City, China Product Name: Model : DVB-T ANTENNA CW-DVB66, CW-DVB83,

More information

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCIS3667. Cover page FCC REPORT (Mobile Phone) Applicant: Address of Applicant: Equipment Under Test (EUT) NETLET ELECTRONICS (HONG KONG) LIMITED 2/F., San Toi Building,37-39 Connaught Road

More information

CONTENTS 6.2 TEST SET-UP...16

CONTENTS 6.2 TEST SET-UP...16 CONTENTS 1. GENERAL INFORMATION...3 2. INTRODUCTION...4 3. PRODUCT INFORMATION...5 3.1 DESCRIPTION OF EUT...5 3.2 SUPPORT EQUIPMENT / CABLES USED...6 3.3 MODIFICATION ITEM(S)...6 4. DESCRIPTION OF TESTS...7

More information

Date: ESPOO Page: 1 (10) Appendices. Tyre Pressure Monitoring Device. Flextronics International Finland.

Date: ESPOO Page: 1 (10) Appendices. Tyre Pressure Monitoring Device. Flextronics International Finland. TEST REPORT Date: ESPOO 25.04.2003 Page: 1 (10) Appendices Number: 1031681 No.1/1 Date of handing in: 07.04.2003 Testedby: Timo Leismala, Product Manager Reviewed by: Janne Nyman, Product Manager, EMC

More information

FCC Part 15B Test Report

FCC Part 15B Test Report Shenzhen Toby Technology Co., Ltd. Report No.: TB-FCC111757 Page: 1 of 18 FCC Part 15B Test Report Application No. : TB11081419 Applicant : Ingtron Enterprise Co., Ltd. Equipment Under Test (EUT) EUT Name

More information

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC FCC ID TEST REPORT

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC FCC ID TEST REPORT CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC ID TEST REPORT TEST REPORT NUMBER : CGZ3150520-00565-EF TEST REPORT For FCC ID 47 CFR PART 15 OCT, 2014 Report Reference No....

More information

FCC REPORT (GSM & WCDMA)

FCC REPORT (GSM & WCDMA) . Cover Page FCC REPORT (GSM & WCDM) Report No: CCISE84 pplicant: Garbarino S ddress of pplicant: Bolivar 874. CB (66) Equipment Under Test (EUT) Product Name: Model No.: Trade mark: Smart phone D5 Datsun

More information

Order Number : GETEC-C FCC Part 15 subpart B Test Report Number : GETEC-E Page 2 / 32 CONTENTS

Order Number : GETEC-C FCC Part 15 subpart B Test Report Number : GETEC-E Page 2 / 32 CONTENTS Test Report Number : GETEC-E3-12-032 Page 2 / 32 CONTENTS 1. GENERAL INFORMATION... 3 2. INTRODUCTION... 4 3. PRODUCT INFORMATION... 5 3.1 DESCRIPTION OF EUT... 5 3.2 SUPPORT EQUIPMENT / CABLES USED...

More information

RF Test Report: Airspan ib440 to 47CFR SC_TR_150_B

RF Test Report: Airspan ib440 to 47CFR SC_TR_150_B RF Test Report: irspan ib44 to 47CFR5.247 FCC ID: O2J-iB44 SC_TR_5_B Prepared for: irspan Communications Ltd Capital Point, 33 Bath Road Slough, Berkshire SL 3UF Sulis Consultants Limited Mead House, Longwater

More information

FCC REPORT. Report Reference No... : TRE R/C.: Simbans Picasso 10 Inch Tablet

FCC REPORT. Report Reference No... : TRE R/C.: Simbans Picasso 10 Inch Tablet FCC REPORT Report Reference No.... : TRE1704011605 R/C.:59884 FCC ID... : Applicant s name... : Address... : Manufacturer...: Address...: Test item description... : Trade Mark... : Model/Type reference...

More information

TEST REPORT. Issued for:

TEST REPORT. Issued for: TEST REPORT FCC ID: 2PMJBV68PRO Product: Smart phone Model No.: BV68Pro dditional Model No.: N/ Trade Mark: Blackview Report No.: TCT823E47 Issued Date: Nov. 2, 28 Issued for: Shenzhen DOKE Electronic

More information

Page: 1 of 15 FCC TEST REPORT. : MEGAVIEW DIGITECH LIMITED : C Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China

Page: 1 of 15 FCC TEST REPORT. : MEGAVIEW DIGITECH LIMITED : C Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China Page: 1 of 15 FCC TEST REPORT Reference No. Applicant Address : WT10125265-S-E-F : MEGAVIEW DIGITECH LIMITED : C1-1001 Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China Equipment Under Test (EUT)

More information

APPLICATION OF CERTIFICATION For. TTE Technology Inc. LCD TV FCC ID: W8ULE32HDE3000

APPLICATION OF CERTIFICATION For. TTE Technology Inc. LCD TV FCC ID: W8ULE32HDE3000 FCC ID:W8ULE32HDE3000 APPLICATION OF CERTIFICATION For TTE Technology Inc. LCD TV Brand Name TCL Model Number LE32HDE3000; LE32HDE3011 LE32HDE5311; LE32HDF3310TA LE32HDF3311; LE32HDF3312 FCC ID: W8ULE32HDE3000

More information

EN : 2015 IEC :2014 TEST REPORT FOR LED ILLUMINATOR MODEL NUMBER: P1347 REPORT NUMBER: E1V1 ISSUE DATE: MAY 15, 2017

EN : 2015 IEC :2014 TEST REPORT FOR LED ILLUMINATOR MODEL NUMBER: P1347 REPORT NUMBER: E1V1 ISSUE DATE: MAY 15, 2017 EN 60601-1-2: 2015 IEC 60601-1-2:2014 TEST REPORT FOR LED ILLUMINATOR MODEL NUMBER: P1347 REPORT NUMBER: 11473017- E1V1 ISSUE DATE: MAY 15, 2017 Prepared for TECHNI-QUIP CORPORATION 530 BOULDER COURT SUITE

More information

FCC PART TEST REPORT SHANGHAI MERIT TECHNOLOGY CORP.

FCC PART TEST REPORT SHANGHAI MERIT TECHNOLOGY CORP. FCC PART 15.247 TEST REPORT For SHANGHAI MERIT TECHNOLOGY CORP. 1058 TAOGAN RD., SHESHAN TOWN, SONGJIANG DISTRICT, SHANGHAI, China FCC ID: XJ6MT-180H Report Type: Original Report Product Type: 4CH 2.4GHZ

More information

T E S T - R E P O R T. No for PC24E-11-FC/R. RF-modem for wireless LAN. Agere Systems Nederland B.V.

T E S T - R E P O R T. No for PC24E-11-FC/R. RF-modem for wireless LAN. Agere Systems Nederland B.V. EMV-Prüfzentrum EMI/EMC-Testcenter Straubing, September 5, 2001 T E S T - R E P O R T No. 56305-10552-1 for RF-modem for wireless LAN Purpose of testing: To show compliance with FCC Code of Federal Regulations,

More information

FCC test report. Via Pezza Alta, 13 I Rustignè di Oderzo (TV)

FCC test report. Via Pezza Alta, 13 I Rustignè di Oderzo (TV) Test report nr. 20811FCC11 Measurements performed in accordance with: FCC Rules: code of Federal Regulations (CFR) no. 47 PART 15 RADIO FREQUENCY DEVICES Product: Tested model: FCC ID Applicant: Manufacturer:

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. CD/USB RADIO. Model Number: TY-CWU700

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. CD/USB RADIO. Model Number: TY-CWU700 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. CD/USB RADIO Model Number: TY-CWU700 FCC ID: ESX-CWU700 Prepared for : Guangzhou Panyu Juda Car

More information

FCCC RF : ZTE APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID STANDARDD : WF722. The product was SPORTON. Page Number (KUNSHAN) INC.

FCCC RF : ZTE APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID STANDARDD : WF722. The product was SPORTON. Page Number (KUNSHAN) INC. FCC RF Test Report 7 FCCC RF Test Report PPLICNT EQUIPMENT BRND NME MODEL NME FCC ID STNDRDD CLSSIFICTION : ZTE CORPORTION : HOME PHONE : ZTE : WF722 : SRQ-WF722 : FCC 47 CFR Part 2, 22(H), 24(E) : PCS

More information

T E S T - R E P O R T. No for. SLG 42 MOBY Component

T E S T - R E P O R T. No for. SLG 42 MOBY Component Straubing, August 04, 1998 T E S T - R E P O R T No. 51905-80643-0 for SLG 42 MOBY Component Applicant: Purpose of Testing: Siemens AG To show compliance with FCC Rules Part 15, Subpart C section 15.209

More information

EMC Test Report. Client: Continental Automotive Systems, Inc. Tested by: Fendy Liauw, Engineering Technician

EMC Test Report. Client: Continental Automotive Systems, Inc. Tested by: Fendy Liauw, Engineering Technician Test Report Number: 3953917EMC7 Rev: Page: 1 of 35 EMC Test Report Project Number: 3953917 Report Number: 3953917EMC7 Revision Level: Client: Continental Automotive Systems, Inc. Equipment Under Test:

More information

Improving the accuracy of EMI emissions testing. James Young Rohde & Schwarz

Improving the accuracy of EMI emissions testing. James Young Rohde & Schwarz Improving the accuracy of EMI emissions testing James Young Rohde & Schwarz Q&A Who uses what for EMI? Spectrum Analyzers (SA) Test Receivers (TR) CISPR, MIL-STD or Automotive? Software or front panel?

More information

FCC PART TEST REPORT. Hantat Technology Ltd.

FCC PART TEST REPORT. Hantat Technology Ltd. FCC PRT 5.247 TEST REPORT For Hantat Technology Ltd. 3/F., C Building, Fuxinlin Industrial Park, Hangch,Xixiang Town, Banan District,Shenzhen,China,5826 FCC ID: V3NHB67 Report Type: Original Report Product

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: D-MINI-2108-2019 FCC ID: NEO-DMINI21082019 To: FCC Parts 2.1046; 2.1049; 22.913(a); 22.917; 24.232; 24.238 & 15.107 3GPP TS 36.143 V10.3.0 This Test Report

More information

Test Report #: Date: January 24, 2006

Test Report #: Date: January 24, 2006 Test Report #: 2415-1 Date: January 24, 2006 CERTIFICATE #2316.01 Issued To: Jeffrey Samstad American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description

More information

Test result 1. Conducted emission EN 55022: A1:2007 EA 3 passed 2. Radiated emission <1GHz (others)

Test result 1. Conducted emission EN 55022: A1:2007 EA 3 passed 2. Radiated emission <1GHz (others) SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-2 of TR-13 5 SUMMARY OF TEST RESULTS Emission testing No. Item Test procedure Page code Number of pages Test result 1. Conducted emission

More information

Fibre Optic Modem ODW-622

Fibre Optic Modem ODW-622 Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.

More information

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST... Table of Contents. GENERL INFORMTION... 5. PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST... 5.2 RELTED SUBMITTL(S) / GRNT (S)... 5.3 TEST METHODOLOGY... 8.4 EQUIPMENT MODIFICTIONS... 8.5 SUPPORT DEVICE...

More information

FCC PART 22, 74, 80 and 90 TEST REPORT. Shenzhen Excera Technology Co., Ltd.

FCC PART 22, 74, 80 and 90 TEST REPORT. Shenzhen Excera Technology Co., Ltd. FCC PRT 22, 74, 8 and 9 TEST REPORT For Shenzhen Excera Technology Co., Ltd. 3rd Floor, Jiada R&D Building, No.5 Songpingshan Road, Hi-Tech Park North, Nanshan District, Shenzhen,China FCC ID: 2E6CER9VHF

More information

Fibre optic router for TP/FT-10 LRW-112PP

Fibre optic router for TP/FT-10 LRW-112PP Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of NYNE MULTIMEDIA INC. Bluetooth Speaker. Model Number: NYNE VIBE FCC ID: AWA-NYNEVIBE

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of NYNE MULTIMEDIA INC. Bluetooth Speaker. Model Number: NYNE VIBE FCC ID: AWA-NYNEVIBE FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of NYNE MULTIMEDIA INC. Bluetooth Speaker Model Number: NYNE VIBE FCC ID: AWA-NYNEVIBE Prepared for: NYNE MULTIMEDIA INC. 3451 LUNAR COURT, OXNARD,

More information

EMC Test Report. 850 Kacena Road Hiawatha, IA 52233

EMC Test Report. 850 Kacena Road Hiawatha, IA 52233 EMC Client: EUT: Crystal Group 850 Kacena Road Hiawatha, IA 52233 Model RS112 No.: R20140819-21 Approved By: Nic S. Johnson, NCE EMC Test Engineering Manager/Technical Manager inarte Certified EMC Engineer

More information

Table of Contents 5. NUMBER OF HOPPING CHANNEL APPLIED PROCEDURES / LIMIT TEST RESULTS 32

Table of Contents 5. NUMBER OF HOPPING CHANNEL APPLIED PROCEDURES / LIMIT TEST RESULTS 32 Table of Contents. GENERL INFORMTION 3. GENERL DESCRIPTION OF EUT 4.2 FCILITIES ND CCREDITTIONS 5.3 DESCRIPTION OF TEST MODES 6.4 TBLE OF PRMETERS OF TEXT SOFTWRE SETTING 7.5 DESCRIPTION OF SUPPORT UNITS(CONDUCTED

More information

TEST REPORT. REPORT NUMBER: B15W50007-FCC-RF_Rev4

TEST REPORT. REPORT NUMBER: B15W50007-FCC-RF_Rev4 TEST REPORT REPORT NUMBER: B5W57-FCC-RF_Rev4 ON Type of Equipment: GPS Tracker Type of Designation: ll-in-one 3 Manufacturer: Presidio Networked Solutions, Inc. CCORDING TO FCC CFR Part 2, FREQUENCY LLOCTIONS

More information

Fibre Optic Modem ODW-611

Fibre Optic Modem ODW-611 Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.

More information

FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT

FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT For XIAMEN YEALINK NETWORK TECHNOLOGY CO., LTD. 7/F HuaLian Electronic BLDG., No.580 JiaHe Road, XiaMen, China September 26, 2005 This Report Concerns:

More information

RF TEST REPORT. Equipment Under Test (EUT): NOTE: The following sample(s) was/were submitted and identified by the client as

RF TEST REPORT. Equipment Under Test (EUT): NOTE: The following sample(s) was/were submitted and identified by the client as 588 West Jindu Road, Xinqiao, Songjiang, 62 Shanghai, China Telephone: +86 () 2 69 5666 Fax: +86 () 2 69 5678 ee.shanghai@sgs.com Page: of 77 Cover Page pplication No.: pplicant: RF TEST REPORT SHEM752849CR

More information

Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. Bluetooth Speaker. Model Number: UB-SPB4M-101 FCC ID: ESXSPB4M

Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. Bluetooth Speaker. Model Number: UB-SPB4M-101 FCC ID: ESXSPB4M FCC ID: ESXSPB4M FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. Bluetooth Speaker Model Number: UB-SPB4M-101 FCC ID: ESXSPB4M Prepared for : Guangzhou

More information

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver Accurate IRIG-B Over Fiber Optics Major Features and Benefits The SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver can send high-accuracy demodulated

More information

BT SOUND BAR. Model Number: AR2010 SBT2014, SBT2014XX, SBT2015,SBT2015XX, ER822FL FCC ID: RI5AR2010

BT SOUND BAR. Model Number: AR2010 SBT2014, SBT2014XX, SBT2015,SBT2015XX, ER822FL FCC ID: RI5AR2010 FCC ID: RI5AR2010 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Dongguan Earson Audio Technology Co., Ltd BT SOUND BAR Model Number: AR2010 Additional Model:AR2010XX, AR3002, AR3002XX, SBT2014,

More information

FCC Test Report. Color LCD Monitor

FCC Test Report. Color LCD Monitor Underwriters Laboratories Inc. www.ul.com/emc www.ulk.co.kr Project: 10CA46552 File: TC8352 Report: 10CA46552-FCC Date: October 13, 2010 Model: EX190W (Basic), RadiForce EX190W FCC Test Report For Color

More information

LONWORKS Fibre Optic Router

LONWORKS Fibre Optic Router LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS

More information

FCC PART 15 TEST REPORT

FCC PART 15 TEST REPORT FCC PART 15 TEST REPORT for Huawei Technologies Co.,Ltd tablet Model Name: T1-A1w FCC ID: QIST1-A1W with Hardware Version: SH1T1A1LM Software Version: T1-A1wV1R1C1 Issued Date: 15--15 TESTING CNAS L57

More information

Report No. 074L076-RFCEP02V01-A. Test Report MSI / MS-6837D

Report No. 074L076-RFCEP02V01-A. Test Report MSI / MS-6837D Test Report Product Name Model No. Transmitter Module Notebook MS-16371,MS-16372 Atheros / AR5BXB63 MSI / MS-6837D Applicant MICRO-STAR INT L Co., LTD. Address No. 69, Li-De St., Jung-He City, Taipei Hsien,

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

FCC Part 15 Certification Test Report. 433 MHz Alarm System

FCC Part 15 Certification Test Report. 433 MHz Alarm System FCC Part 15 Certification Test Report 433 MHz Alarm System FCC ID: Q6K 1000-7253 FCC Rule Part: 15.231 ACS Report Number: 03-0111-15B Manufacturer: 3SI Security Systems Model: 1000-7253 with variants Test

More information

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F Test Report Product Name: IQ Pager (Receiver) FCCID: WDC-IQ2008 Model No.: IQ2008 Applicant: HME Wireless, Inc. 1400 Northbrook Parkway, Suite 320, Suwanee City, GA, 30024, U.S.A Date Receipt : 12/20/2008

More information

FCC PART 15 TEST REPORT

FCC PART 15 TEST REPORT FCC PART 15 TEST REPORT No. I17Z60314SRD06 for HMD Global Oy Smart Phone TA-1033 with FCC ID: 2AJOTTA-1033 Hardware Version: 3 Software Version: 000C_3_050 Issued Date: 2017-04-17 Note:The test results

More information

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F Test Report Product Name: IQ Pager (Receiver) FCCID: WDC-IQ2008 Model No.: IQ2008L Applicant: HME Wireless, Inc. 1400 Northbrook Parkway, Suite 320, Suwanee City, GA, 30024, U.S.A Date Receipt : 12/20/2008

More information

TEST REPORT. Test Report No. : UL-RPT-RP C V2.0. Date of Issue: 06 March 2018

TEST REPORT. Test Report No. : UL-RPT-RP C V2.0. Date of Issue: 06 March 2018 Test Report No. : UL-RPT-RP11913492-2216C V2.0 Manufacturer : Raspberry Pi (Trading) Ltd Model No. : Raspberry Pi 3 Model B+ FCC ID : 2ABCB-RPI3BP Technology : Bluetooth Low Energy Test Standard(s) : FCC

More information

Report No R-RFCEP02V01. Test Report MSI / MS-6837D. Date of Receipt Aug. 21, Issued Date Sep. 11, 2007

Report No R-RFCEP02V01. Test Report MSI / MS-6837D. Date of Receipt Aug. 21, Issued Date Sep. 11, 2007 Test Report Product Name Model No. Transmitter Module Notebook MS-163D, EX610 Atheros / AR5BXB63 MSI / MS-6837D Applicant Address MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien,

More information

Report No R-RFCEP02V01. Test Report. MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

Report No R-RFCEP02V01. Test Report. MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C. Test Report Product Name Model No. Notebook MS-1242, U200 Transmitter Module. Ralink / RT3090 (MS-6891) Bluetooth Module MSI / MS-6837D Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He

More information

FCC Test Report (Class II Permissive Change)

FCC Test Report (Class II Permissive Change) FCC Test Report (Class II Permissive Change) Product Name Intel Wireless-AC 9560 Model No. 9560NGW FCC ID. 2AKHF9560NG Applicant TONGFANG HONGKONG (SUZHOU) LIMITED Address NO. 83 Wu Lane, Suzhou Industrial

More information

Report No. 074L146-RFCEP02V01. Test Report MSI / MS-6837D. Date of Receipt Apr. 24, Issued Date May. 28, 2007

Report No. 074L146-RFCEP02V01. Test Report MSI / MS-6837D. Date of Receipt Apr. 24, Issued Date May. 28, 2007 Test Report Product Name Model No. Transmitter Module Notebook MS-16342 Atheros / AR5BXB63 MSI / MS-6837D Applicant Address MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan,

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test of: Blighter B422-HPNB Aux Unit FCC ID: UFQB400HPNBAUX To: FCC Part 90: 2010 Subpart F in accordance with RFI Test Plan RFI/REGE1/TP75565JD03 Test Report Serial No: RFI-RPT-RP76945JD15B

More information

TEST REPORT. Power Spout PLT V. tested to. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

TEST REPORT. Power Spout PLT V. tested to. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices EMC Technologies (NZ) Ltd PO Box 68-307,Newton Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100

More information

CERTIFICATION APPLICATION TEST REPORT

CERTIFICATION APPLICATION TEST REPORT BEC INCORPORATED CERTIFICATION APPLICATION TEST REPORT TEST STANDARDS: FCC Part 15 Subpart C, Section 15.247 Intentional Radiator ARRIS Model VMS4100 Set Top Box FCC ID: ACQ-VMS4100 REPORT BEC-1792-03

More information

EMC Test Report. Client: Crestron Electronics, Inc. Tested by: Jeremy O. Pickens, Senior EMC Engineer

EMC Test Report. Client: Crestron Electronics, Inc. Tested by: Jeremy O. Pickens, Senior EMC Engineer Test Report Number: 3919823EMC1 Rev. Page: 1 of 26 EMC Test Report Project Number: 3919823 Report Number: 3919823EMC1 Revision Level: Client: Crestron Electronics, Inc. Equipment Under Test: infinet EXTM

More information

EMC TEST REPORT. Product : Digital Camcorder Model No. : SCD5000. SAMSUNG ELECTRONICS Co., Ltd. EMC Test Laboratory. Project No.

EMC TEST REPORT. Product : Digital Camcorder Model No. : SCD5000. SAMSUNG ELECTRONICS Co., Ltd. EMC Test Laboratory. Project No. Page 1 of 17 EMC TEST REPORT Project No. :LBE031059 Product : Digital Camcorder Model No. : SCD5000 Date of test : May 7 ~ 9, 2003 Issued Date : May 9, 2003 Tested by: Jay Yong, PARK / Test Engineer Reviewed

More information

FCC PART RSS-GEN, ISSUE 5, APRIL 2018 RSS-247, ISSUE 2, FEBRUARY 2017 TEST REPORT SZ DJI TECHNOLOGY CO., LTD

FCC PART RSS-GEN, ISSUE 5, APRIL 2018 RSS-247, ISSUE 2, FEBRUARY 2017 TEST REPORT SZ DJI TECHNOLOGY CO., LTD FCC PART 5.247 RSS-GEN, ISSUE 5, APRIL 208 RSS-247, ISSUE 2, FEBRUARY 207 TEST REPORT For SZ DJI TECHNOLOGY CO., LTD 4th floor, West Wing, Skyworth Semiconductor Design Building NO.8 Gaoxin South 4th Ave,

More information

FCC TEST REPORT D-LINK CORPORATION

FCC TEST REPORT D-LINK CORPORATION FCC TEST REPORT REPORT NO.: RF921014R02 MODEL NO.: DWL-120(refer to page 6 for other models) RECEIVED: October 14, 2003 TESTED: October 16 ~ October 17, 2003 APPLICANT: ADDRESS: D-LINK CORPORATION NO.8,

More information

Raspberry Pi (Trading) Ltd. Raspberry Pi. dated. 9th December 2013

Raspberry Pi (Trading) Ltd. Raspberry Pi. dated. 9th December 2013 FCC ID: 2ABCB-RPI2 T545 of 37 EMC Testing ---------- ( Cambridge Ltd. ) ---------- EMC Consultancy EMC Training 23, Headington Drive, Cambridge. CB 9HE Tel : 0954 25974 (test site) or : 0223 2440 (accounts)

More information

FCC PART 22H, PART 24E MEASUREMENT AND TEST REPORT. Shanghai AirM2M Communication Technology Co., Ltd

FCC PART 22H, PART 24E MEASUREMENT AND TEST REPORT. Shanghai AirM2M Communication Technology Co., Ltd FCC PART 22H, PART 24E MEASUREMENT AND TEST REPORT For Shanghai AirM2M Communication Technology Co., Ltd No. 666.East beijing road, Shanghai, China FCC ID: 2AEGG-AIR208 Report Type: Original Report Product

More information

A Test Lab Techno Corp. FCC. RF Test Report. Product Type. : Mobile Hotspot. Applicant. : Netgear Inc.

A Test Lab Techno Corp. FCC. RF Test Report. Product Type. : Mobile Hotspot. Applicant. : Netgear Inc. FCC RF Test Report Product Type Applicant : Mobile Hotspot : Netgear Inc. Address : 350 East Plumeria Drive, San Jose, CA 95134 Trade Name Model Number Test Specification : NETGEAR : AC810S-300 : FCC 47

More information

Radio Test report

Radio Test report Radio Test report 2824333 based on: Radio Equipment Regulations for Japan 82. abg compact flash module Summit Data Communications SDC-CFG Report number: 2824333 Contents MIN MODULE...3 INTRODUCTION...3

More information

Open Rack Specification 2.1 Update

Open Rack Specification 2.1 Update Rack and Power Open Rack Specification 2.1 Update Steve Mills Technical Lead Facebook Busbar Thickness Tolerance Reduction Reduce Rack Frame Tolerance Agenda Add Appendix D: Optional Rack-level EMI test

More information