1 Early Outcomes (9 months) with a Toric Accommodating IOL How do They Fit in My refractive Practice Douglas Katsev MD Sansum Clinic i Chairman Ophthalmology Santa Barbara CA 1
2 Disclosure Consulting Fee: Abbott Medical Optics; Bausch + Lomb Speakers Bureau: Alcon Laboratories, Inc.; Allergan Ownership Interest: TruVision 2
3 Model Specifications Model Recommended Starting A-constant Recommended Starting ACD Overall Diameter Available Now Diopter Power Accomodating Toric IOL BL1UT 119.1* 5.61 mm* 11.5 mm 17.0 to 25.0 D in 0.50 D steps Cylinder powers IOL plane Cylinder powers corneal plane 1.25, 2.00, 2.75 D 0.83, 1.33, 1.83 D Optic body diameter 5.0 mm Anterior surface Aspheric with axis marks Posterior surface Aspheric toric (cyl at 1.25, 2.00, 2.75 D) Material body and plates Silicone with enhanced UV protection; 10% UV cutoff at 400 nm Material loop (haptics) Polyimide Refractive index at 35 o C 1.43 Edge design 360º posterior square edge Delivery system Crystalsert IOL Delivery System 3
4 Accomadating Toric How do I position it? A broader range of vision with astigmatic correction May read but NO promise Does NOT produce all ranges of Vision all the time Telling the patient the real results will not hurt your conversion rate but will help with patients satisfaction It may take time and work to get the result Need to offer a good reading multifocal IOL too 4
5 Accomodating Lens with and without Toric Work with Previous Refractive These are harder patients, they need to know it! Works with Coma/Trefoil Previous RK, need to know they are harder Lasik especially hyperopic do well in my hands Informed consent is the most important Prepare for reops PRK/LASIK Prepare for IOL exchange Especially with RK but only after healing 5
6 Retina s View of Crystalens Less issue than multifocals Easier to work around view when operating Can use with SMD and ERM with proper consent Less chance they tell the patient later that lens makes thing difficult 6
7 Crystalens AO - Non Post Refractive Absolute Prediction Error <0.5D 100% TMF 84% 93% 94% Restor 84% 88% 85% 80% 73% 67% 60% 40% 40% 44% 20% 0% 0.25D 0.5D 0.75D 1D PreOp Est Prediction Error ORA N=864; Mean N=869; Mean
8 Dr. Douglas Katsev Santa Barbara Surgery Center ORA Outcome Analysis
9 Accomodating Toric Global ORA Data (non VerifEye) Astigmatism Management Pre-Op Keratometric Astigmatism N=70; Mean 1.64 D Range 0.25 D to 4.68D Prost-Op Refractive Astigmatism N=70; Mean 0.43 D Range 0.00 D to 1.50 D
10 Accommodating Toric Personal Data Astigmatism Management (early data) PreOp Keratometry Post Op Manifest Ref N=5; Mean N=5; Mean
11 Accommodating Toric Personal Data Astigmatism Management Pre-Op Keratometric Astigmatism Post-Op Refractive Astigmatism N=11; Mean 2.30 D 1.04 N=11; Mean 0.51 D 0.47 Range:103Dto468D D Range:000Dto150D D
12 Accommodating Toric Personal Data Post-op op Refractive Astigmatism N=11; Mean 0.51 D 0.47
13 Accommodating Toric Absolute Prediction i Error and Distribution ib i ORA N=11 Mean 0.31 D 0.19
14 Comparison with Standard Toric IOLs TRULIGN Toric IOL 1 AcrySof IQ Toric 2 Tecnis Toric IOL 3 Uncorrected Distance Visual Acuity: Eyes 20/ % 93.8% 97.0% Rotational Stability: Rotation 5 at 6 months vs prior 96.1% 81.1% 94.1% assessment Residual Cylinder: Eyes D 95.5% 87.0% 94.1% Data on file, Bausch & Lomb Incorporated. Study 650. Results of a prospective, multicenter, randomized, single-masked, clinical study of 229 eyes of 229 subjects. 2. AcrySof IQ Toric Directions for Use. 3. Tecnis Toric IOL Directions for Use.
15 Outstanding Rotational Stability Absolute rotation results at 4 to 6 months D 2.00 D 2.75 D All Toric 5.00,% ,% Mean IOL rotation < % exhibited IOL rotational stability of 5 1. Data on file, Bausch & Lomb Incorporated. Study CSR-PMA-20feb2012.doc T 54 p75
16 Premium IOL Complaints : 2164 cataract surgeries implanted premium lenses 570 times (25% conversion rate) I received 12 patient complaints related to the use of these lenses 2.1% of cases 16
17 Convertion Rates to Premium IOL 2012 Total 29% TMF 13% Toric 11.5% Crystalens 4.5% 17
18 Convertion Rates to Premium IOL 1 st half year 2013 Total 36% TMF 12% Toric 12.5% Crystalens 12% 18
19 Convertion Rates to Premium IOL 2 st half year 2013 Total 38% increased 2% over 1 st have 12% over previous 2 years TMF 5% decreased Toric 8.5% Decreased 4% Crystalens 16% Trulign 8% 19
20 Premium IOL Complaints 2013 to date ~800cases implanted premium lenses 332 times (38% conversion rate) I received 1 patient complaints related to the use of these lenses 0.3 % of cases *time could bring more *complaint was didn t use ORA 20
21 My Ideal Patient for Accommodating Toric Most appropriate for astigmatic cataract patients who perform a variety of activities that require a range of vision. My patients Computer, ipad, iphone and texting drive and flying participate in sports NOT for the person that wants to read at close in a dark room NOT for the person who has good accommodation and wants Refractive Lensectomy Data on file, Bausch & Lomb Incorporated, Study TRULIGN Toric IOL Directions for Use.
22 The Ideal Patient (cont) Good ocular health hnot impacting best-corrected visual acuity Active lifestyle Realistic expectations 22
23 PRE-OP PEARLS Spherical Targeting First eye implant should be targeted between and D Second eye implant targeted for plano based on first eye results Ora can help tighten results but doesn t eliminate touch ups 23
24 Marking the Cornea Prior to surgery, the subject s operative eye should be marked to identify the axis of placement TruVision works well ORA works well if you fill with viscoelastic and then mark cornea, reposition to marks after viscoelastic removed NOTE: I use the TRULIGN Toric IOL Calculator software program 24
25 Symmetrical Capsulorhexis Create a symmetrical capsulorhexis of 5.0 to 6.0 mm Very small and very large should be avoided d Femto will make this none issue o o 25
26 Polishing the Capsule Very important t change for me Polish the anterior and posterior capsule Meticulous cortical cleanup is very important to minimize capsular contraction and posterior capsular opacification (PCO) Special attention should be given to keeping the zonular apparatus intact, because IOL placement is highly dependent on an intact capsular zonular system and capsular bag HELP PREVENT Zsyndrome 26
27 Accommodating Toric Toric IOL Insertion IOL Delivery System requires a 2.85-mm opening for injection I prefer the injector to be deep in eye for easier haptic in bag placement Verify that the IOL is right-side-up (refer to Directions for Use) The round knob leading haptic on the right (remember round to the right ) 27
28 INTRA/Post-OPERATIVE PEARLS I put a drop of atropine I put a suture in *new FDA approved sealant may stop I have them use reading glasses 2 weeks 28
29 My Summary of Accommodating Toric IOL A broader range of vision than standard toric IOLs 1 Excellent visual acuity at intermediate and distance 2 Outstanding rotational stability 2,3 Effective cylinder correction 2 Residual cylinder 1.0 D: 95.5% of eyes % of patients reported no visual disturbances 2 1. TRULIGN Toric IOL Directions for Use. 2. Data on file, Bausch & Lomb Incorporated. Study AcrySof IQ Toric Directions for Use. 29
30 The Biggest Reason it Fits in My Practice Increase Conversion rates Less Complaints Happy Patients 30
White Paper. Astigmatism Management With Toric IOLs The Importance of Rotational Stability After IOL Implantation. Xiaolin Gu, M.D., PhD.
White Paper Astigmatism Management With Toric IOLs The Importance of Rotational Stability After IOL Implantation Xiaolin Gu, M.D., PhD. Introduction Cataracts, or clouding of the crystalline lens, are
More information* Villegas EL, Alcón E, Artal P. Minimum amount of astigmatism that should be corrected. J Cataract Refract Surg 2014; 40: n My SIA: Ø Centroid
Astigmatism correction in cataract surgery: A work in progress 9 things you should know Douglas D. Koch, M.D. Cullen Eye Institute Baylor College of Medicine Houston, Texas Financial disclosure: AMO Alc
More informationToric intraocular lenses
Supplement to EyeWorld August 2015 Driving adoption and outcomes with toric IOLs: Pre-, intra-, and postoperative pearls for success 2014 ASCRS Clinical Survey: Trends in toric IOL implementation Click
More information4/9/2016. Sources of. Single-angle vs. double-angle plots for astigmatism data. Commercial Toric IOL calculators. Unexpected residual astigmatism!
Sources of Corneal astigmatism measurements Methods of calculation Corneal surgically induced astigmatism (SIA) Toric IOL misalignment Unexpected residual astigmatism! Single-angle vs. double-angle plots
More informationArthur Cummings FRCSEd
How to Improve your Refractive Cataract Surgery Outcomes by Skilful Interpretation of Corneal Mapping Course IC-16 ESCRS Copenhagen 10 th September 2016 Consultant for Alcon / WaveLight/TearLab Arthur
More informationPostoperative Astigmatic Outcomes Based on the Haptic Axis of Intraocular Lenses Inserted in Cataract Surgery
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2011;25(1):22-28 DOI: 10.3341/kjo.2011.25.1.22 Original Article Postoperative Astigmatic Outcomes Based on the Haptic Axis of Intraocular Lenses Inserted
More informationHandout Course Title : Astigmatisme Management with toric IOL
Handout Course Title : Astigmatisme Management with toric IOL ESCRS Milano 2012 Level :Basic Course leader : Jerome jean Bovet Course duration : 2 hours Faculty : Jerome Bovet, Warren Hill Keiki Mehta
More informationPremium treatment starts with premium diagnosis
by i-optics Premium treatment starts with premium diagnosis Complete your cataract-refractive platform The premium IOL opportunity Premium IOL market to nearly double in next 5 years 2013 1.6 million 22
More informationFemtosecond Cataract Surgery: Correction of Astigmatism and Complex Cases Financial Disclosures Femtosecond Laser Utility in Cataract Surgery
1 2 3 4 5 6 7 Femtosecond Cataract Surgery: Correction of Astigmatism and Complex Cases Michael J Taravella, MD Director: Cornea and Refractive Surgery University of Colorado Financial Disclosures Consultant
More informationAXsys Studay Data and Press Release Reference
Clinically Tested to be the World s Most Accurate Toric Marking Device AXsys Studay Data and Press Release Reference Press Release Reference electronic leveling device for implantation of a toric iol The
More informationIrregular Corneal Astigmatism & Cataract
Costas Karabatsas MD, PhD, MRCOphth, FEBOphth, FRCS Ophth Irregular Corneal Astigmatism & Cataract (assessing ocular surface, IOL selection) In both LRS and Cataract Surgery aim = Emmetropia Refractive
More informationProspective study of toric IOL outcomes based on the Lenstar LS 900 W dual zone automated keratometer
Gundersen and Potvin BMC Ophthalmology 2012, 12:21 RESEARCH ARTICLE Open Access Prospective study of toric IOL outcomes based on the Lenstar LS 900 W dual zone automated keratometer Kjell Gunnar Gundersen
More informationNovel Microscope Mounted Digital Keratoscope for Intra-Operative Toric IOL Alignment
Cronicon OPEN ACCESS EC OPHTHALMOLOGY Research Article Novel Microscope Mounted Digital Keratoscope for Intra-Operative Toric IOL Alignment Sviatlana M Ilyina 1 *, Siarhei M Lohash 2 and Alex Artsyukhovich
More informationManagement of astigmatism at the time of cataract or refractive lens surgery has evolved to include arcuate keratotomy and toric
Management of Astigmatism with the LENSAR Laser System with Streamline Mark Packer Mark Packer MD Consulting, Inc., Boulder, CO, US DOI: https://doi.org/10.17925/usor.2017.12.99 Management of astigmatism
More informationDisclosure. Getting Up to Date with LASIK. Modern advancements LASIK. What we re curing. Changing the corneal surface
Getting Up to Date with LASIK Disclosure I am not a paid consultant to any drug or device company. Stillwater, MN Adjunct Associate Professor University of Minnesota LASIK Use one instrument to make a
More informationAbstract. imedpub Journals Vol.3 No.2:27. Introduction
Research Article imedpub Journals http://www.imedpub.com/ Journal of Eye & Cataract Surgery DOI: 10.21767/2471-8300.100027 Intraoperative Biometry versus Conventional Methods for Predicting Intraocular
More informationComparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators
Original Article http://dx.doi.org/10.3349/ymj.2015.56.4.1097 pissn: 0513-5796, eissn: 1976-2437 Yonsei Med J 56(4):1097-1105, 2015 Comparison of the Astigmatic Power of Toric Intraocular Lenses Using
More informationPOST-OPERATIVE ASTIGMATISM AFTER SICS AND PHACOEMULSIFICATION.
4 POST-OPERATIVE ASTIGMATISM AFTER SICS AND PHACOEMULSIFICATION. Dr.Vijay Damor, Dr.Anupama Mahant, Department of ophthalmology,amc MET Medical college. Ahmedabad pin 380008 Abstract : Background: Astigmatism
More informationTHE CHALLENGES CORNEAL IRREGULARITIES POST-LASIK ECTASIA IS THIS A GOOD LASIK CANDIDATE? 3/5/2015. FITTING THE IRREGULAR CORNEA Challenges & Solutions
DISCLOSURE STATEMENT No disclosure statement. CORNEAL IRREGULARITIES Course Title: Lecturer: FITTING THE IRREGULAR CORNEA Challenges & Solutions Phyllis Rakow, COMT, NCLM, FCLSA(H) Keratoconus Pseudokeratoconus
More informationTotal corneal astigmatism in older adults taking into account posterior corneal astigmatism by ray tracing
ARTICLE Total corneal astigmatism in older adults taking into account posterior corneal astigmatism by ray tracing Alvaro Rodríguez Ratón, MD 1 ; Javier Orbegozo Gárate, MD 1 ; Iñaki Basterra Barrenetxea,OD
More informationAXsys Study Data and Press Release Reference
Clinically Tested to be the World s Most Accurate Toric Marking Device Takayuki Akahoshi, MD Tokyo Japan Ophthalmologist Anterior Segment I WORKED WITH ASICO LLC TO DESIGN AN AXsys TM TORIC MARKING DEVICE
More informationThe efficacy of Toric IOL in comparison to LRI in correcting pre-existing astigmatism in phacoemulsification
Original Research Article The efficacy of Toric IOL in comparison to LRI in correcting pre-existing astigmatism in phacoemulsification Parul Singh 1, Ruchika Agarwal 2*, Sanjeev Rohatgi 2, Malini Vohra
More informationDOWNLOAD ASTIGMATIC TECHNIQUE IN ONE STEP RAINBOW HOLOGRAPHY
ASTIGMATIC TECHNIQUE IN ONE PDF DOWNLOAD 1 / 5 2 / 5 3 / 5 astigmatic technique in one pdf astigmatic technique in one pdf Signs and symptoms. Although astigmatism may be asymptomatic, higher degrees of
More informationNo financial interest
Management of high astigmatism after penetrating keratoplasty Ahmed Sherif MD Assistant Professor of Ophthalmology Cairo University No financial interest 1 Incidence Several reports state that 15-31% of
More informationAssessment & management of irregular astigmatism
Assessment & management of irregular astigmatism Athens, March 2018 D. Epstein, MD, PhD, FARVO No financial interest What is an irregular astigmatism? A question that starts at the wrong end... How about
More informationORIGINAL ARTICLE. Primary Topography-Guided LASIK: Treating Manifest Refractive Astigmatism Versus Topography-Measured Anterior Corneal Astigmatism
ORIGINAL ARTICLE Primary Topography-Guided LASIK: Treating Manifest Refractive Astigmatism Versus Topography-Measured Anterior Corneal Astigmatism Avi Wallerstein, MD, FRCSC; Mathieu Gauvin, BEng, PhD;
More information2nd ESASO Anterior Segment Academy April 2016, Milano/Italy
2nd ESASO Anterior 28 30 April 2016, Milano/Italy Istituto Clinico Humanitas Humanitas Congress Centre Via Manzoni, 56 20089 Rozzano, Milan Congress Chairmen: José L. Güell, Paolo Vinciguerra www.esaso.org/2nd-esaso-anteriorsegment-academy-2016/
More information2Optimizing the Refractive
Chapter 02 3/4/11 4:29 PM Page 1 2Optimizing the Refractive Outcome: Correction of Astigmatism in Cataract Surgery By: Robert M. Kershner, M.D., FACS General Considerations Lens extraction with the implantation
More informationPhacoemulsification: The first 50 Cases
Phacoemulsification: The first 5 Cases Aneeq Ullah Baig Mirza*, Samina Jehangir**, Wasif Mohy-ud-din Kadri** * Department of Ophthalmology Islamic International Medical College and Railway Hospital Rawalpindi.
More informationRichard N. McNeely 1,2, Salissou Moutari 3, Eric Pazo 1,2 and Jonathan E. Moore 1,2*
McNeely et al. Eye and Vision (2018) 5:7 https://doi.org/10.1186/s40662-018-0103-4 RESEARCH Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent
More informationPredicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent
Journal of the Optical Society of Korea Vol. 17, No. 2, April 2013, pp. 219-223 DOI: http://dx.doi.org/10.3807/josk.2013.17.2.219 Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical
More informationIndex. D DALK, 69, 155 Differential sector index (DSI), 92 Discriminant function analysis, DMEK, 23 Donor factors, 156 DSAEK, 23
A Abberrometry, intraoperative, 66 Aberrated corneas, topography-guided laser for, 146 Aberration coefficient, 99 corneal, 94 Ablation cylindrical, 131 hyperopic, 130, 131 pattern, design and planning,
More informationDevelopment of a program for toric intraocular lens calculation. considering posterior corneal astigmatism, incisioninduced
DOI 10.1007/s00417-016-3446-3 CATARACT Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective
More informationStandard for Reporting Refractive Outcomes of Intraocular Lens Based Refractive Surgery
EDITORIAL Standard for Reporting Refractive Outcomes of Intraocular Lens Based Refractive Surgery Dan Z. Reinstein, MD, MA(Cantab), FRCSC; Timothy J. Archer, MA(Oxon), DipCompSci(Cantab); Sathish Srinivasan,
More informationHandheld Shack Hartmann Wavefront Sensor. Jim Schwiegerling, Ph.D. Department of Ophthalmology and Optical Sciences The University of Arizona
Handheld Shack Hartmann Wavefront Sensor Jim Schwiegerling, Ph.D. Department of Ophthalmology and Optical Sciences The University of Arizona COLLABORATORS Erin M. Harvey, PhD Velma Dobson, PhD Joseph M.
More information1. Standard Equipment Subjective Eye Tester Name of Parts Details of Auxiliary Lenses Measuring Performance...
Notification Dear Users, Thank you for your purchase of R 2500 Refractor. Please take time to read our user s manual carefully before use. This guarantees you to make full use of this unit and prolongs
More informationSTUDY OF ASTIGMATISM IN SMALL INCISSION CATARACT SURGERY BETWEEN TEMPORAL AND SUPERIOR INCISSIONS K. J. N. Sivacharan 1, G.
STUDY OF ASTIGMATISM IN SMALL INCISSION CATARACT SURGERY BETWEEN TEMPORAL AND SUPERIOR INCISSIONS K. J. N. Sivacharan 1, G. Hanumantharao 2 HOW TO CITE THIS ARTICLE: K. J. N. Sivacharan, G. Hanumantharao.
More informationCHANGE ON THE HORIZONTAL AND VERTICAL MERIDIANS OF THE CORNEA AFTER CATARACT SURGERY*
15 Merriam Final 11/9/01 11:22 AM Page 187 CHANGE ON THE HORIZONTAL AND VERTICAL MERIDIANS OF THE CORNEA AFTER CATARACT SURGERY* BY John C. Merriam, MD, Lei Zheng, MD (BY INVITATION), Joanna Urbanowicz,
More informationOver the last decade, a vast improvement on intraocular
REVIEW Posterior Astigmatism: Considerations for Cataract Refractive Surgery Planning Milton S. Yogi, MD, MBA1 Bruna V. Ventura, MD, PhD2 Eliane M. Nakano, MD3 1 Head, Cataract Department, Beneficência
More informationClinical results of arcuate incisions to correct astigmatism
Clinical results of arcuate incisions to correct astigmatism Kurt A. Buzard, MD, Eduardo Laranjeira, MD, Bradley R. Fundingsland, BS ABSTRACT Purpose: To evaluate the effectiveness of arcuate incisions
More informationCircular Keratotomy to Reduce Astigmatism and Improve Vision in Stage I and II Keratoconus
Circular Keratotomy to Reduce Astigmatism and Improve Vision in Stage I and II Keratoconus Jorg H. Krumeich, MD; Guy M. Kezirian, MD, FACS ABSTRACT PURPOSE: To report the use of circular keratotomy in
More informationClinical Study Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass Instrument
BioMed Research International Volume 2013, Article ID 124327, 6 pages http://dx.doi.org/1155/2013/124327 Clinical Study Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass
More informationAstigmatism: analysis and synthesis of the astigmatic ametropia
http://eoftalmo.org.br OPINION OF SPECIALISTS Astigmatism: analysis and synthesis of the astigmatic ametropia Astigmatismo: análise e síntese da ametropia astigmática Analysis and synthesis of the astigmatic
More informationResearch conducted over the past 15 years has yielded a
Visual Psychophysics and Physiological Optics Longitudinal Change and Stability of Refractive, Keratometric, and Internal Astigmatism in Childhood Erin M. Harvey, 1,2 Joseph M. Miller, 1 3 J. Daniel Twelker,
More informationEffect of Pupil Size on Uncorrected Visual Acuity in Pseudophakic Eyes With Astigmatism
ORIGINAL ARTICLE Effect of Pupil Size on Uncorrected Visual Acuity in Pseudophakic Eyes With Astigmatism Kazuhiro Watanabe, MD; Kazuno Negishi, MD; Murat Dogru, MD; Takefumi Yamaguchi, MD; Hidemasa Torii,
More informationAstigmatismamongotherRefractiveErrorsinChildrenofSouthernSriLanka. Astigmatism among other Refractive Errors in Children of Southern Sri Lanka
: F Diseases Volume 15 Issue 1 Version 1.0 Year 2015 Type: Double Blind Peer Reviewed International Research Journal Publisher: Global Journals Inc. (USA) Online ISSN: 2249-4618 & Print ISSN: 0975-5888
More informationArcuate Keratotomy for High Postoperative Keratoplasty Astigmatism Performed With the IntraLase Femtosecond Laser
Arcuate Keratotomy for High Postoperative Keratoplasty Astigmatism Performed With the IntraLase Femtosecond Laser Luca Buzzonetti, MD; Gianni Petrocelli, MD; Antonio Laborante, MD; Emilio Mazzilli, MD;
More informationEvaluation of Opposite Clear Corneal Incision in Controlling Astigmatism in Cataract Patients Undergoing Phacoemulsification Surgery
Evaluation of Opposite Clear Corneal Incision in Controlling Astigmatism in Cataract Patients Undergoing Phacoemulsification Surgery J.S.Bhalla, Meenakshi Rani, Surbhi Gupta Department of Ophthalmology,
More informationLASIK for post penetrating keratoplasty astigmatism and myopia
Br J Ophthalmol 1999;83:113 118 113 The Eye Institute, Chatswood, NSW, Australia S K Webber M A Lawless G L Sutton C M Rogers Correspondence to: Dr Michael Lawless, Level 3, 7 Victoria Avenue, Chatswood,
More informationComparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism
Original Article Yonsei Med J 216 Nov;57(6):1475-1481 pissn: 513-5796 eissn: 1976-2437 Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High
More informationContents. Innovation Is Just a First Step 3 Mark Wright, OD, FCOVD. Closing the Knowledge Gap 4 Gina Wesley, OD, FAAO
Contents INNOVATION IN PRACTICE Innovation Is Just a First Step 3 Mark Wright, OD, FCOVD PRACTITIONER PERSPECTIVES & BUSINESS AUTHOR INSIGHTS Closing the Knowledge Gap 4 Gina Wesley, OD, FAAO What Do Customers
More informationOrthokeratology (Ortho-K), or corneal refractive therapy, is. Toric Double Tear Reservoir Contact Lens in Orthokeratology for Astigmatism ARTICLE
ARTICLE Toric Double Tear Reservoir Contact Lens in Orthokeratology for Astigmatism Jaume Pauné, M.Sc., Genís Cardona, Ph.D., and Lluïsa Quevedo, Ph.D. Objectives: This study aimed at assessing the performance
More informationNew method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder
ARTICLE New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder Noel Alpins, FRANZCO, FRCOphth, FACS, James K.Y. Ong, BOptom, Dr.rer.nat, George Stamatelatos,
More informationIrregular Astigmatism Diagnosis And Treatment
Irregular Astigmatism Diagnosis And Treatment 1 / 5 2 / 5 3 / 5 Irregular Astigmatism Diagnosis And Treatment Irregular Astigmatism: Diagnosis and Treatment. Ming Wang, ed., Thorofare, NJ: Slack Inc.;
More informationNon-penetrating Femtosecond Laser. intrastromal astigmatic keratotomy (ISAK) Patients With Mixed Astigmatism After Previous Refractive Surgery
ORIGINAL ARTICLE Non-penetrating Femtosecond Laser Intrastromal Astigmatic Keratotomy in Patients With Mixed Astigmatism After Previous Refractive Surgery Jan Venter, MD; Rodney Blumenfeld, MD; Steve Schallhorn,
More informationThe Short Term Effects of a Single Limbal Relaxing Incision Combined with Clear Corneal Incision
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2010;24(2):78-82 DOI: 10.3341/kjo.2010.24.2.78 Original Article The Short Term Effects of a Single Limbal Relaxing Incision Combined with Clear Corneal
More informationAstigmatism in Children: Changes in Axis and Amount from Birth to Six Years
Astigmatism in Children: Changes in Axis and Amount from Birth to Six Years Jane Gwiazda, Mitchell Scheiman,* Indra Mohindra, and Richard Held Noncycloplegic refractions of, children aged - years revealed
More informationA novel method for human Astigmatism formulation and measurement
Available online at http://www.ijabbr.com International journal of Advanced Biological and Biomedical Research Volume 1, Issue 8, 2013: 874-884 A novel method for human Astigmatism formulation and measurement
More informationCorrecting Your Vision: Advice and Opinions from an Eye Surgeon Health Radio April 17, 2007 Mark Walker, M.D. Introduction
Correcting Your Vision: Advice and Opinions from an Eye Surgeon Health Radio April 17, 2007 Mark Walker, M.D. Please remember the opinions expressed on Patient Power are not necessarily the views of Health
More informationAstigmatism: Aberration or ametropia?
http://eoftalmo.org.br OPINION OF SPECIALISTS Astigmatism: Aberration or ametropia? Astigmatismo: Aberração ou Ametropia? Astigmatismo: Aberración o ametropía? Sidney Julio Faria e Sousa - Faculdade de
More information620 Rejwrts Investigative Ophthalmology
Rejwrts Investigative Ophthalmology August D. E.: Retinal dystrophy in the rat a pigment epithelial disease, INVEST. OPHTHALMOL. :,. Color vision: blue deficiencies in? ANTHONY J. ADAMS,* RICHARD BAL-
More informationMost advanced, portable, high-power 532nm Diode-Pumped Solid-State Photocoagulator
Ophthalmology Since 1970 Most advanced, portable, high-power 532nm Diode-Pumped Solid-State Photocoagulator breakthrough technology FROM A BREAKTHROUGH COMPANY For treatment flexibility, the LaserLink
More informationResults of Intraoperative Manual Cyclotorsion Compensation for Myopic Astigmatism in Patients Undergoing Small Incision Lenticule Extraction (SMILE)
ORIGINAL ARTICLE Results of Intraoperative Manual Cyclotorsion Compensation for Myopic Astigmatism in Patients Undergoing Small Incision Lenticule Extraction (SMILE) Sri Ganesh, MS, DNB; Sheetal Brar,
More informationRefractive, anterior corneal and internal astigmatism in the pseudophakic eye
Refractive, anterior corneal and internal astigmatism in the pseudophakic eye Jesper F. Bregnhøj, 1,2 Pourang Mataji 1,2 and Kristian Næser 1,2 1 Department of Ophthalmology, Aarhus University Hospital,
More informationPerioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery
접수번호 : 2008-114 Korean Journal of Ophthalmology 2009;23:240-248 ISSN : 1011-8942 DOI : 10.3341/kjo.2009.23.4.240 Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery Yang Kyeung
More informationA R Sebai Sarhan, Harminder S Dua, Michelle Beach
Br J Ophthalmol 2000;84:837 841 837 Division of Ophthalmology and Visual Sciences, University of Nottingham, University Hospital, Queen s Medical Centre, Nottingham NG7 2UH A R S Sarhan H S Dua M Beach
More informationbalt5/zov-opx/zov-opx/zov01005/zov a washingd S 12 10/4/05 14:54 Art: OPX Input-nlm ORIGINAL ARTICLE
1040-5488/05/8210-0001/0 VOL. 82, NO. 10, PP. 1 1 OPTOMETRY AND VISION SCIENCE Copyright 2005 American Academy of Optometry ORIGINAL ARTICLE Progressive Powered Lenses: the Minkwitz Theorem JAMES E. SHEEDY,
More informationClinical outcomes of Transepithelial photorefractive keratectomy to treat low to moderate myopic astigmatism
Xi et al. BMC Ophthalmology (2018) 18:115 https://doi.org/10.1186/s12886-018-0775-5 RESEARCH ARTICLE Clinical outcomes of Transepithelial photorefractive keratectomy to treat low to moderate myopic astigmatism
More informationCV-5000 INSTRUCTION MANUAL COMPU-VISION CV-5000
CV-5000 INSTRUCTION MANUAL COMPU-VISION CV-5000 INTRODUCTION Thank you for purchasing the TOPCON Compu-Vision CV-5000. This instrument is used to measure refractive power of eyes and to test the binocular
More informationAstigmatism in infant monkeys reared with cylindrical lenses
Vision Research 43 (2003) 2721 2739 www.elsevier.com/locate/visres Astigmatism in infant monkeys reared with cylindrical lenses Chea-su Kee, Li-Fang Hung, Ying Qiao, Earl L. Smith III * College of Optometry,
More informationOPTOMETRY. An analysis of the astigmatic changes induced by accelerated o rt ho ke ratolog y I ORIGINALPAPER 1
OPTOMETRY I ORIGINALPAPER 1 An analysis of the astigmatic changes induced by accelerated o rt ho ke ratolog y Clin Exp Optom ; 85: 5: 84-93 John Mountford* DipAppSc FAAO FVCO FCLS Konrad Pesudovst PhD
More informationLin Liu, Jun Zou *, Hui Huang, Jian-guo Yang and Shao-rong Chen
Liu et al. Diagnostic Pathology 2012, 7:55 RESEARCH Open Access The influence of corneal astigmatism on retinal nerve fiber layer thickness and optic nerve head parameter measurements by spectral-domain
More informationWe are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors
We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,500 108,000 1.7 M Open access books available International authors and editors Downloads Our
More informationCycloplegic Refractions of Infants and Young Children: The Axis of Astigmatism
Cycloplegic Refractions of Infants and Young Children: The Axis of Astigmatism Velma Dobson,* Anne B. Fulton, f and S. Lawson Sebris* Review of the cycloplegic refractions of all children who were first
More informationsp)oken of as asthenopic troubles, and which werc due to some
MITTENDORF: Ocular Headaches. 339 FOUR THOUSAND CASES OF OCULAR HEAD- ACHES AND THE DIFFERENT STATES OF REFRACTION CONNECTED THEREWITH. BY DR. WV. F. AIITTENDORF, NEWV YORK. About four years ago I reported
More informationOPTOMETRY INVITED REVIEW. A review of astigmatism and its possible genesis
C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY INVITED REVIEW A review of astigmatism and its possible genesis Clin Exp Optom 2007; 90: 1: 5 19 Scott A Read PhD Michael J Collins PhD Leo G Carney
More informationFNP3 Series Tri-Lens for Nichia NS6x083 and NS6x183 LEDs
FNP3 Series Tri-Lens for Nichia NS6x083 and NS6x183 LEDs High efficiency 4 beams available MR-16 size tri-lens The FNP3 tri-lens offers MR16 size lenses specifically designed for the Nichia 083/183 series
More informationPROCEEDINGS OF SPIE. Volumetric, dashboard-mounted augmented display
PROCEEDINGS OF SPIE SPIEDigitalLibrary.org/conference-proceedings-of-spie Volumetric, dashboard-mounted augmented display David Kessler, Christopher Grabowski David Kessler, Christopher Grabowski, "Volumetric,
More informationTreatment of astigmatism-related amblyopia in 3- to 5-year-old children
Vision Research 44 (2004) 1623 1634 www.elsevier.com/locate/visres Treatment of astigmatism-related amblyopia in 3- to 5-year-old children Erin M. Harvey a, *, Velma Dobson a,b, Joseph M. Miller a,c,d,
More informationRefractor. Model:BR-7. Operation Manual. <Important> Read this manual thoroughly before use. Keep this manual on hand at all times.
Refractor Model:BR-7 Operation Manual Read this manual thoroughly before use. Keep this manual on hand at all times. I-050707 EU Representative FAUSTO GUZZETTI VIA SOLFERINO,5 21057 OLGIATE
More informationDate: 11/03/2014 Our ref: I write in response to your request for information in relation to ophthalmology equipment used in NHS Lothian.
Lothian NHS Board Waverley Gate 2-4 Waterloo Place Edinburgh EH1 3EG Telephone 0131 536 9000 Fax 0131 536 9088 www.nhslothian.scot.nhs.uk Date: 11/03/2014 Our ref: 4328 Enquiries to: Bryony Pillath Extension:
More informationEyes with regular astigmatism have two orthogonal focal. Accommodation in Astigmatic Children During Visual Task Performance
Clinical and Epidemiologic Research Accommodation in Astigmatic Children During Visual Task Performance Erin M. Harvey, 1,2 Joseph M. Miller, 1 3 Howard P. Apple, 1 Pavan Parashar, 4 J. Daniel Twelker,
More informationWe are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors
We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,700 108,500 1.7 M Open access books available International authors and editors Downloads Our
More informationAstigmatic axis and amblyopia in childhood
Astigmatic axis and amblyopia in childhood Maths Abrahamsson and Johan Sjo strand ABSTRACT. Purpose: This study is part of a larger project whose aim is to evaluate the relationship between refractive
More informationPHABLABS 4.0 Gobo Batman/Slide projector
PHABLABS 4.0 Gobo Batman/Slide projector Title of the workshop: The Gobo Batman/Slide projector Target audience: 14 /16? Time planning: Part 1 (15 min), part 2 (15 min), part 3 (5 min). Estimated cost:
More informationMulticolor Scan Laser Photocoagulator MC-500 Vixi
Multicolor Scan Laser Photocoagulator MC-500 Vixi MC-500 The Versatile Laser Photocoagulator Selectable configuration of laser colors and delivery units Multiple scan patterns Enhanced usability LPM (Low
More informationApproved by Principal Investigator Date: Approved by Super User: Date:
Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC Dektak 3030 Stylus Profilometer Version 2011 May 16 I. Purpose This Standard Operating Procedure
More informationFull-Thickness Astigmatic Keratotomy Combined With Small-Incision Lenticule Extraction to Treat High-Level and Mixed Astigmatism
CLINICAL SCIENCE Full-Thickness Astigmatic Keratotomy Combined With Small-Incision Lenticule Extraction to Treat High-Level and Mixed Astigmatism Bu Ki Kim, MD, MS,* Su Joung Mun, MD, PhD,* Dae Gyu Lee,
More informationORIGINAL ARTICLE. Corneal and Refractive Error Astigmatism in Singaporean Schoolchildren: a Vector-Based Javal s Rule
1040-5488/01/7812-0881/0 VOL. 78, NO. 12, PP. 881 887 OPTOMETRY AND VISION SCIENCE Copyright 2001 American Academy of Optometry ORIGINAL ARTICLE Corneal and Refractive Error Astigmatism in Singaporean
More informationORIGINAL ARTICLE. Amblyopia in Astigmatic Infants and Toddlers
1040-5488/10/8705-0330/0 VOL. 87, NO. 5, PP. 330 336 OPTOMETRY AND VISION SCIENCE Copyright 2010 American Academy of Optometry ORIGINAL ARTICLE Amblyopia in Astigmatic Infants and Toddlers Velma Dobson*,
More information1. Introduction. Correspondence should be addressed to Edmund Arthur; arthur
Hindawi Publishing Corporation Journal of Ophthalmology Volume, Article ID 989, 7 pages http://dx.doi.org/.//989 Clinical Study Postoperative Corneal and Surgically Induced Astigmatism following Superior
More informationProposed classification for topographic patterns seen after penetrating keratoplasty
Br J Ophthalmol 1999;83:403 409 403 Department of Ophthalmology, Bristol Eye Hospital, Bristol C H Karabatsas S D Cook J M Sparrow Correspondence to: Costas H Karabatsas, PO Box 16757, Athens 115 02, Greece.
More informationSelection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter
Fibre Optic Communications The greatest advantage of fibre cable is that it is completely insensitive to electrical and magnetic disturbances. It is therefore ideal for harsh industrial environments. It
More informationMultiFlex An Innovative I 2 PL Device and an Outstanding Nd:YAG Laser in One Versatile Platform
MultiFlex An Innovative I 2 PL Device and an Outstanding Nd:YAG Laser in One Versatile Platform The Ellipse MultiFlex The best of pulsed light and laser technology in a single platform MultiFlex makes
More informationCA-800 Tear Module. Rick Gaudenti. Product Manager, Refraction Mar 2017
CA-800 Tear Module Rick Gaudenti Product Manager, Refraction Mar 2017 Meibomian Gland Imaging Meibomian Gland [MEIB] Viewing Meibomian Images are displayed in the center of the screen Two types of an adjustable
More informationDr Noel Alpins AM Digest of Personal and Professional biography
Dr Noel Alpins AM Digest of Personal and Professional biography Work Address: 7 Chesterville Road Cheltenham 3192 Dr Noel Alpins AM has been specialising in Cataract and Refractive Surgery since founding
More informationOPERATOR MANUAL TOMEY REFRACTION SYSTEM TAP-1000 & TCP-1001
OPERATOR MANUAL TOMEY REFRACTION SYSTEM TAP-1000 & TCP-1001 Read this instruction manual carefully before using this instrument to ensure correct and safe operation. If you have questions about operations,
More informationAstigmatism is a common refractive error 1 and an important. The Changing Profile of Astigmatism in Childhood: The NICER Study
Clinical and Epidemiologic Research The Changing Profile of Astigmatism in Childhood: The NICER Study Lisa O Donoghue, Karen M. Breslin, and Kathryn J. Saunders School of Biomedical Sciences, University
More informationChrominance Subsampling in Digital Images
Chrominance Subsampling in Digital Images Douglas A. Kerr Issue 2 December 3, 2009 ABSTRACT The JPEG and TIFF digital still image formats, along with various digital video formats, have provision for recording
More informationApplication Note: Using the Turner Designs Model 10-AU Fluorometer to Perform Flow Measurements in Sanitary Sewers by Dye Dilution
Instrument set-up: Model 10-AU Digital Fluorometer equipped with the 13 mm x 100 mm cuvette holder; and a 10-056/10-056R (546 nm) Excitation Filter, a 10-052/10-052R (>570 nm) Emission Filter, 10-053/10-053R
More information