Abstract. imedpub Journals Vol.3 No.2:27. Introduction

Size: px
Start display at page:

Download "Abstract. imedpub Journals Vol.3 No.2:27. Introduction"

Transcription

1 Research Article imedpub Journals Journal of Eye & Cataract Surgery DOI: / Intraoperative Biometry versus Conventional Methods for Predicting Intraocular Lens Power: A Closer Look at Patients Undergoing Toric Lens Implantation for Astigmatic Correction Emily Waisbren 1*, David Ritterband 1, Li Wang 2, Danielle Trief 3, Richard Koplin 1 and John Seedor 1 1 Department of Ophthalmology, The New York Eye and Ear Infirmary of Mt. Sinai, New York, USA 2 Cullen Eye Institute, Baylor College of Medicine, New York, USA 3 Harkness Eye Institute, Department of Ophthalmology, Columbia University School of Medicine, New York, USA * Corresponding author: Emily Waisbren, Department of Ophthalmology, The New York Eye and Ear Infirmary of Mt. Sinai, New York, USA, Tel: , Fax ; ewaisbren@gmail.com Received date: March 21, ; Accepted date: May 15, ; Published date: May 22, Citation: Waisbren E, Ritterband D, Wang L, Trief D, Koplin R, et al. () Intraoperative Biometry versus Conventional Methods for Predicting Intraocular Lens Power: A Closer Look at Patients Undergoing Toric Lens Implantation for Astigmatic Correction. J Eye Cataract Surg 3: 27. doi: / Copyright: Waisbren E, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Abstract Purpose: To compare intraoperative refractive biometry to conventional methods for intraocular lens (IOL) power calculation in patients receiving toric IOLs. Setting: The New York Eye and Ear Infirmary of Mt. Sinai. Design: Retrospective Case Series. Methods: Separate cohorts of patients undergoing primary cataract extraction with toric IOL implantation were analyzed. In 52 patients, Optivue Refractive Analysis (ORA) was used to guide IOL power determination and axis adjustment. In a separate cohort of 52 patients, conventional methods were used to determine the astigmatic axis and calculate the IOL power. Prediction error (Actual spherical equivalent (SE)-Predicted SE) and median absolute error (MAE) were calculated in each group. The percentage of eyes within ± 0.50 diopters (D) and ± 1.00 D of the refractive target along with the residual cylinder and deviation from intended axis were compared. Results: The 52 patients in the ORA cohort achieved statistically significant better postoperative MAE than those in the conventional group (MAE 0.34 ± 0.29 (conventional) vs ± 0.22 (ORA), p=0.05). When ORA were used, patients were more likely to fall within 0.5D of the targeted refraction (87% vs. 79%). Residual astigmatism was less than 1D in 87% of the ORA group compared to 69% of the conventional group. In the ORA group, 29% of eyes ended up within 10 degrees of the intended axis compared to 12% of eyes in the conventional group. Conclusions: The current study shows that intraoperative biometry significantly improves refractive target outcomes for patients undergoing toric IOL implantation in comparison to conventional methodology. Introduction Traditional intraocular lens (IOL) power calculation methods rely on mathematical assumptions which render them inherently inaccurate, particularly in eyes that fall outside of the "normal" bell curve such as post-laser vision correction (LVC) or in eyes with extreme hyperopia or myopia. This is due to multiple factors, including the inability of manual keratometers to accurately measure the anterior corneal curvature, the use of incorrect refractive indices to calculate corneal power, and the inaccurate prediction of effective lens position [1,2]. The traditional lens calculation formulas require an estimation of the position of the IOL in the eye. This factor is known as the effective lens position (ELP). IOL formulas differ in the way they calculate ELP. Most of the modern day formulae are based upon the theoretical equation designed by Fedorov and its modifications [3,4]. Conventional methods of intraocular lens (IOL) power calculation are based on preoperative biometry using keratometry (K), axial length (AL), and, in some formulas, additional measurements such as anterior chamber depth. While newer third and fourth-generation formulas, and improvements in biometric technology have increased the accuracy of IOL power prediction, only about 70% of eyes fall within +0.5 diopters (D) of the targeted refraction after cataract surgery [2]. In patients with preexisting astigmatism, toric lens implantation with conventional calculations have been shown to improve uncorrected visual acuity and provided greater spectacle independence than lenses that did not correct astigmatism [5,6]. Intraoperative aberrometry may be advantageous for patients undergoing toric intraocular lens implantation for astigmatic Under License of Creative Commons Attribution 3.0 License This article is available from: 1

2 correction. Not only does the ORA allow the surgeon to confirm or revise the IOL power selection that was based on preoperative biometry calculations, but it also allows for intraoperative axis adjustment. In addition, it can help eliminate potential sources of errors such as posterior corneal astigmatism, surgically induced astigmatism, and tilting or head misalignment either with preoperative testing or perioperative axis marking. In a previous study by our group at the New York Eye and Ear Infirmary, A we analyzed 529 eyes undergoing uncomplicated cataract surgery. The toric subgroup was found to have a statistically significant difference in MAE in postoperative refractive outcomes when using ORA versus conventional methods (p=0.005). However, in all of these patients, ORA were used intraoperatively. Therefore, there was no control group of toric IOL patients to compare to, who used conventional methods only. In the current study, we analyzed the refractive target outcomes using an intraoperative aberrometer (Optiwave Refractive Analysis [ORA] System WaveTec Vision, Inc, Aliso Viejo, CA) and compared it toa control group cohort using conventional preoperative methods in whom the ORA was not utilized. Methods This series compared two separate cohorts of patients undergoing primary cataract extraction with toric IOL implantation. The group undergoing conventional preoperative calculations underwent surgery from 2010 through 2012, and the group undergoing ORA intra-operatively underwent surgery from 2013 through All patients who underwent primary phacoemulsification and IOL implantation for cataract without additional visually significant ocular comorbidities were queried from our office medical records and the ORA surgical outcomes database. An Acrysof toric IOL ( Alcon, Ft worth, Tx) was used in all cases. (Table 1) Chart reviews were conducted to document preoperative demographic data and biometric measurements. Exclusion criteria were as follows: A preoperative diagnosis of irregular astigmatism, keratoconus, previous corneal laser vision correction, prior intraocular surgery, and other ocular disease that might prevent a best-corrected vision. Postoperatively, we excluded patients with a best-corrected visual acuity of worse than 20/30 three weeks after surgery. Patients who developed cystoid macular edema were also excluded. Our study involved two experienced cataract surgeons at one institution. The study protocol was approved by the Investigational Review Board at our institution. Preoperatively, the axial length (AL) and keratometric values (K) were obtained using partial coherence optical biometry (IOL Master, Carl Zeiss Meditec, Jena, Germany). K values were also obtained manually and through corneal topography (Pentacam, Oculus, Dutenhofen, Germany). If the measurements were inconsistent, they were repeated. The IOL predictive formulas used in the IOL Master (i.e. Holladay, Haigis, or SRK-T) were chosen by the surgeon based on preoperative patient data. For each study eye, the surgeon used his/her best judgment to choose atoric IOL based on the patient s targeted postoperative refraction. For toric IOL axis placement, all patients underwent pre-operative corneal topography using Pentacam which uses Scheimpflug technology. Calculation of power of the implanted IOL was determined using: 1. The HicSoaPro software for toric IOL calculations (IOLMaster ), and/or 2. The online toric calculator from Alcon ( The Baylor Nomogram, which considers the effect of posterior corneal astigmatism [7]. The K value from the IOL Master was plugged into the formulas. The surgeon compared the lens recommendations from the HicSoaPro software and the online toric manufacturer s calculator to choose a lens power and astigmatic correction based on their best judgment. To determine the proper axis at which the toric lens should be aligned, the astigmatic axis was measured manually as well as from the corneal topography and IOLMaster. The keratometry and axis were used from the two devices that showed the most consistent results. If none of the three were consistent, the measurements were repeated until some consensus could be reached. The ORA s Wavetec vision website ( home.wavetecvision.com/) was used to remotely enter the patient data, including which keratometric method was used, the magnitude of the flat and steep K as well as the axis, whiteto-white measurement and the axial length. The target refraction was entered as well as data about the IOL to be implanted, including manufacturer, model, power, and formula used to determine the lens power, and predicted refractive outcome. Prior to entering the operating room with the patient in a seated position, the surgeon used a marking pen to delineate the horizontal axis using a Stephens Bubble Level Toric Axis Marker (Stephens Instruments, Lexington Kentucky). In the operating room, the conventional group underwent routine phacoemulsification through a temporal clear corneal incision. Prior to implanting the IOL, viscoelastic was used to fill the capsular bag. A Henderson toric axis IOL marker (Katena instruments, Denville NJ) was used to mark the axis of astigmatism at the predetermined axis determined from the preoperative calculations. The IOL was implanted and aligned to the correct axis marked on the cornea. Care was taken during viscoelastic removal to prevent rotation of the toric IOL after placement. In the ORA toric subgroup, after the cataract was removed, the capsular bag and anterior chamber were filled with viscoelastic. The intraocular pressure was measured using an applanation tonometer in order to ensure that the eye was pressurized to at least 30 mmhg, as per the manufacturer s recommendations. As with the conventional methods, a Henderson toric axis IOL marker was used to mark the axis of astigmatism at the predetermined calculated astigmatic axis. The ORA was then used to determine the aphakic refractive state of the eye, and the ORA's calculation of the predicted postoperative refraction was used to either confirm or adjust the toric IOL power prior to implantation. The toric IOL was then implanted into the eye, and was aligned with the previously calculated marked toric axis. The ORA was then utilized for realtime axis adjustment. The lens was rotated according to the ORA s recommendations. The measurement was repeated until 2 This article is available from:

3 there was no residual astigmatism measured and confirmed with the ORA platform. The predicted postoperative refraction for the implanted IOL was recorded and was imported to the database. The predicted refractive refraction from the IOL Master printout for the actual implanted IOL was also recorded. Postoperatively, best-corrected visual acuity and the spherical equivalent were calculated from a refraction performed by an experienced optometrist or ophthalmologist during an office visit at a minimum of three weeks after surgery. The prediction error for the implanted IOL power was calculated as the difference between the postoperative outcome and the predicted refraction from the IOL Master for the lens that was implanted or the predicted refraction from the ORA for the lens that was implanted. Median absolute errors (MAE) were derived for all refractive outcomes. Results A total of 104 patients were included in the series. There were 52 eyes in the conventional calculations subgroup and 52 eyes in the ORA subgroup (Table 1). Patients in the ORA cohort achieved a statistically significant lower MAE than those in the conventional subgroup (0.34 ± 0.29 (conventional) vs ± 0.22 (ORA), (p=0.05). Of the ORA group, 45/52(87%) of eyes were within 0.5D of the targeted refraction, compared to 41/52 (79%) in the conventional group (p=0.437) (Table 2). Table 1: Patient & Operative Characteristics of Study Eyes. Characteristic Conventional Group (N=52) ORA Group (N=52) Mean ± SD or % Mean ± SD or % Male 56% 46% Age at time of surgery (years) 66 ± 9 67 ± 8 Preoperative astigmatism 2.23 ± 1.38 (min 0.76D, max 9.4D) 2.19 ± 0.88 (min 0.82D, max 4D) Average K (IOL Master) ± ± 1.99 Axial Length (mm) ± ± 1.71 Implanted IOL Power (D) 16 ± 5 17 ± 5 Implanted IOL Type Alcon toric 100% 100% D=Diopter, IOL=Intraocular lens, K=Keratometry Table 2: Refractive Outcomes. Conventional Group (N=52) ORA Group (N=52) MAE, D 0.34 ± ± 0.22 P value* % within ± 0.50D Residual Astigmatism 0D 18/52 (35%) 14/52 (27%) <0.5D 28/52 (54%) 34/52 (65%) <1D 36/52 (69%) 45/52 (87%) MAE=Mean Absolute Error, D=Diopter, * Chi square With the help of the ORA, surgeons were able to reduce astigmatism to less than 1D in 45/52 (87%) of patients compared to only 36/52 (69%) of patients who underwent conventional planning without ORA, which almost reached statistical significance (p=0.059). Of the ORA group, 14/52 (27%) had no postoperative residual astigmatism vs. 18/52 (35%) of the conventional group. Of the remaining patients with residual astigmatism postoperatively, 15/52 (29%) of the ORA group refracted to an axis within 10 degrees of the intended axis at which the IOL was aligned in the operating room, compared to 6/52 (12%) of the conventional patients (p=0.133). Discussion Preoperative astigmatism 1.5D or greater is present in 20% of all patients undergoing operation for age-related cataracts [8]. It is well known that residual postoperative astigmatism is an important cause for the inability to obtain emmetropia after cataract surgery. Residual postoperative astigmatism is an important reason for spectacle use even in patients with a spherical equivalent refraction ± 0.5 D [9]. Correcting residual astigmatism results in improved visual acuity at all contrast levels at both distance and near [10]. Refractive astigmatism can be corrected by three main methods: implanting a toric IOL, changing the corneal curvature through laser vision correction (LVC), or through limbal relaxing incision(s) [11]. Generally, relaxing incisions may correct up to 3D of astigmatism, LVC may correct up to 6D of astigmatism, and toric IOLs can correct up to 8D of astigmatism [12]. Despite the weakness inherent in correcting astigmatism with manual incisions, the advent of the femtosecond-laser created corneal incisions has raised the possibility that arcuate incisions created with the femtosecond laser may be more accurate not only in Under License of Creative Commons Attribution 3.0 License 3

4 depth but length than those incisions created manually and might attain the accuracy seen with toric IOLs. Nevertheless, toric IOL's have significant advantages including the ability to achieve correction of higher amounts of astigmatism, minimally traumatic surgeries, improved accuracy (less likely to regress with healing), and the ability to readjust the axis or exchange the alignment post-operatively. You cannot easily undo corneal incisions, whether made manually or made with the femtosecond laser. It has also been our group s experience that LRI's for astigmatism greater than 1.5D has less satisfactory long-term results and stability. One potential downfall of toric implants is the postoperative rotation of the implant within the capsular bag. A rotation of greater than 30 degrees off the intended axis could potentially reduce the power of the IOL to the point of eliminating its correcting effect [13]. These cases may require surgical repositioning of the IOL and increase the risk for an untoward complications including rupture of the capsule. In addition, patients who are paying out-of-pocket for a premium toric IOL, typically have higher expectations for postoperative results. In these patients, accurate determination of the amount of astigmatism and its axis is paramount. It is important preoperatively to determine the amount of refractive, lenticular and corneal astigmatism. As the patient is undergoing cataract surgery, the lenticular astigmatism should not be factored into preoperative calculations. As the corneal incision may induce astigmatism, surgeons must consider this in their calculation of how much astigmatism needs to be corrected, and the axis of their wound. The manufacturer's toric calculators take this into account and recommend a final cylindrical power and axis of IOL orientation. While conventional methods of IOL calculation are accurate in the majority of eyes, their accuracy is reduced in eyes that deviate from the normal", such as eyes with high astigmatic error [5,6,14]. This is in part due to preoperative factors such as the inability to accurately measure the amount or axis of astigmatism, as well as operative factors such as correct alignment of the IOL. Traditionally, surgeons choose the alignment of a toric IOL based on preoperative topography and biometry calculations. The ability to use ORA to guide IOL alignment and adjust the power of the lens has intuitive benefits. Our study identified a statistically significant difference in predictive accuracy when using the ORA compared with conventional methods for patients received a toric implant. Hatch et al. looked specifically at toric IOL patients, and analyzed residual astigmatism using ORA versus conventional methods. Their study demonstrated that cataract extraction with toric IOL placement aided by intraoperative aberrometry (37 eyes) was 2.4 times more likely to have less than 0.50D of residual astigmatism after surgery compared to standard methods (27 eyes) [15]. One advantage of the ORA in these patients is that the technology is the first to allow for the adjustment of both power and axis of the implanted IOL in the perioperative setting. It allows for real time analysis of astigmatism, which is subject to errors due to induced astigmatism from corneal incision as well as torsion of the eye when the patient is in the supine position. The ORA avoids some of the errors in preoperative measurements and allows us to resolve disagreements between preoperative tests. Traditional biometry only measures anterior corneal astigmatism. By measuring the aphakic refraction of the whole eye, the ORA may also factor in the posterior corneal astigmatism that is not identified by conventional measurements, potentially leading to better outcomes [16]. Our study identified a statistically significant difference in the predictive accuracy when using the ORA compared with conventional methods for the patients who required a toric IOL. It is possible that in addition to the anterior corneal astigmatism, these eyes have significant posterior astigmatism that is not identified by conventional measurements. ORA s wave front technology incorporates the contributions of the posterior cornea into the IOL calculation, which could potentially lead to better outcomes and explain the advantage of ORA in these patients. Additionally, the ORA helps guide the surgeon with alignment of the IOL based on axis of astigmatism while in the operating room. The surgeon is able to take into account intraoperative variables that may affect astigmatism such as the cataract incision and torsion of the globe that occurs when the patient is in the supine position. Traditional toric implant alignment is dependent on preoperative topography and the determination of the "best guess" for the astigmatic axis. The ORA allows for real-time power and axis adjustment and may contribute to better outcomes in these patients, not only in its ability to modify the power of the toric IOL, but also in the ability to modify the axis of astigmatism. Conclusion This study demonstrated a number of potential advantages of intraoperative methodology for IOL power calculation. The aphakic refraction is an optical measurement obtained using wavefront technology. It allows us to use the optics of the eye instead of relying on estimations of corneal power. We believe that intraoperative aberrometry is a promising technology that will allow for more reliable, predictable, and accurate surgical decisions. Based on the findings of this study, intraoperative refractive biometry may be a helpful adjuvant in obtaining target refractions in patients undergoing cataract surgery, particularly those requiring astigmatic correction. Only the absolute error was significantly improved in these patients using ORA. The other variables tested, such as proximity to the targeted axis, were also improved in the ORA subgroup, but they did not achieve statistical significance. A larger study may help elucidate if these variables are significantly different. What Was Known Prior to undergoing cataract surgery, all patients must undergo calculations to determine which lens power to use. While these calculations have proven to be extremely accurate, newer technology allows surgeons to repeat and confirm these calculations intraoperatively. 4 This article is available from:

5 What This Paper Adds Intraoperative aberrometry leads to more accurate refractive target outcomes if used in lieu of or in conjunction with traditional lens calculations in patients undergoing toric lens implantation for astigmatic correction? References 1. Hoffer KJ (2009) Intraocular lens power calculation after previous laser refractive surgery. J Cataract Refract Surg 35: Wang L, Shirayama M, Ma XJ (2011) Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm. J Cataract Refract Surg 37: Fedorov SN, Kolinko AI, Kolinko AI (1967) Estimation of optical power of the intraocular lens. VestnOftalmol 80: Hoffer KJ (1993) The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 19: T. Miyake, K. Kamiya, R. Amano (2014) Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism. J Cataract Refract Surg 40: Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL (2011) Formula choice: Hoffer Q, Holladay 1, or SRK/ T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg 37: Koch DD, Jenkins RB, Weikert MP, Yeu E, Wang L (2013) Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism. J Cataract Refract Surg 39: OstriC, Falck L, Boberg-Ans G, Kessel L (2015) The need for toric intra-ocular lens iplantation in public ophthalmology departments. Acta Ophthalmol 93: Wilkins MR, Allan B, Rubin G (2009) Spectacle use after routine cataract surgery.br J Ophthalmol 93: Lehmann RP, Houtman DM (2012) Visual performance in cataract patients with low levels of postoperative astigmatism: full correction versus spherical equivalent correction. Clin Ophthalmol 6: Mozayan E, Lee JK (2014) Update on astigmatism management. Curr Opin Ophthalmol 25: Rubenstein JB, Raciti M (2013) Approaches to corneal astigmatism in cataract surgery. Curr Opin Ophthalmol 24: Felipe A, Artigas JM, Diez-Ajenjo A (2011) Residual astigmatism produced by toric intraocular lens rotation. J Cataract Refract Surg 37: Koch DD, Jenkins RB, Weikert MP, Yeu E, Wang L (2013) Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism. J Cataract Refract Surg 39: Hatch KM, Woodcock EC, Talamo JH (2015) Intraocular lens power selection and positioning with and without intraoperative aberrometry. Journal of Refractive Surgery 31: Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, et al. (2012) Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg 38: Under License of Creative Commons Attribution 3.0 License 5

4/9/2016. Sources of. Single-angle vs. double-angle plots for astigmatism data. Commercial Toric IOL calculators. Unexpected residual astigmatism!

4/9/2016. Sources of. Single-angle vs. double-angle plots for astigmatism data. Commercial Toric IOL calculators. Unexpected residual astigmatism! Sources of Corneal astigmatism measurements Methods of calculation Corneal surgically induced astigmatism (SIA) Toric IOL misalignment Unexpected residual astigmatism! Single-angle vs. double-angle plots

More information

White Paper. Astigmatism Management With Toric IOLs The Importance of Rotational Stability After IOL Implantation. Xiaolin Gu, M.D., PhD.

White Paper. Astigmatism Management With Toric IOLs The Importance of Rotational Stability After IOL Implantation. Xiaolin Gu, M.D., PhD. White Paper Astigmatism Management With Toric IOLs The Importance of Rotational Stability After IOL Implantation Xiaolin Gu, M.D., PhD. Introduction Cataracts, or clouding of the crystalline lens, are

More information

* Villegas EL, Alcón E, Artal P. Minimum amount of astigmatism that should be corrected. J Cataract Refract Surg 2014; 40: n My SIA: Ø Centroid

* Villegas EL, Alcón E, Artal P. Minimum amount of astigmatism that should be corrected. J Cataract Refract Surg 2014; 40: n My SIA: Ø Centroid Astigmatism correction in cataract surgery: A work in progress 9 things you should know Douglas D. Koch, M.D. Cullen Eye Institute Baylor College of Medicine Houston, Texas Financial disclosure: AMO Alc

More information

AXsys Studay Data and Press Release Reference

AXsys Studay Data and Press Release Reference Clinically Tested to be the World s Most Accurate Toric Marking Device AXsys Studay Data and Press Release Reference Press Release Reference electronic leveling device for implantation of a toric iol The

More information

Toric intraocular lenses

Toric intraocular lenses Supplement to EyeWorld August 2015 Driving adoption and outcomes with toric IOLs: Pre-, intra-, and postoperative pearls for success 2014 ASCRS Clinical Survey: Trends in toric IOL implementation Click

More information

Novel Microscope Mounted Digital Keratoscope for Intra-Operative Toric IOL Alignment

Novel Microscope Mounted Digital Keratoscope for Intra-Operative Toric IOL Alignment Cronicon OPEN ACCESS EC OPHTHALMOLOGY Research Article Novel Microscope Mounted Digital Keratoscope for Intra-Operative Toric IOL Alignment Sviatlana M Ilyina 1 *, Siarhei M Lohash 2 and Alex Artsyukhovich

More information

Handout Course Title : Astigmatisme Management with toric IOL

Handout Course Title : Astigmatisme Management with toric IOL Handout Course Title : Astigmatisme Management with toric IOL ESCRS Milano 2012 Level :Basic Course leader : Jerome jean Bovet Course duration : 2 hours Faculty : Jerome Bovet, Warren Hill Keiki Mehta

More information

Total corneal astigmatism in older adults taking into account posterior corneal astigmatism by ray tracing

Total corneal astigmatism in older adults taking into account posterior corneal astigmatism by ray tracing ARTICLE Total corneal astigmatism in older adults taking into account posterior corneal astigmatism by ray tracing Alvaro Rodríguez Ratón, MD 1 ; Javier Orbegozo Gárate, MD 1 ; Iñaki Basterra Barrenetxea,OD

More information

Richard N. McNeely 1,2, Salissou Moutari 3, Eric Pazo 1,2 and Jonathan E. Moore 1,2*

Richard N. McNeely 1,2, Salissou Moutari 3, Eric Pazo 1,2 and Jonathan E. Moore 1,2* McNeely et al. Eye and Vision (2018) 5:7 https://doi.org/10.1186/s40662-018-0103-4 RESEARCH Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent

More information

Prospective study of toric IOL outcomes based on the Lenstar LS 900 W dual zone automated keratometer

Prospective study of toric IOL outcomes based on the Lenstar LS 900 W dual zone automated keratometer Gundersen and Potvin BMC Ophthalmology 2012, 12:21 RESEARCH ARTICLE Open Access Prospective study of toric IOL outcomes based on the Lenstar LS 900 W dual zone automated keratometer Kjell Gunnar Gundersen

More information

Douglas Katsev MD Sansum Clinic Chairman Ophthalmology Santa Barbara CA

Douglas Katsev MD Sansum Clinic Chairman Ophthalmology Santa Barbara CA Early Outcomes (9 months) with a Toric Accommodating IOL How do They Fit in My refractive Practice Douglas Katsev MD Sansum Clinic i Chairman Ophthalmology Santa Barbara CA 1 Disclosure Consulting Fee:

More information

Postoperative Astigmatic Outcomes Based on the Haptic Axis of Intraocular Lenses Inserted in Cataract Surgery

Postoperative Astigmatic Outcomes Based on the Haptic Axis of Intraocular Lenses Inserted in Cataract Surgery pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2011;25(1):22-28 DOI: 10.3341/kjo.2011.25.1.22 Original Article Postoperative Astigmatic Outcomes Based on the Haptic Axis of Intraocular Lenses Inserted

More information

Management of astigmatism at the time of cataract or refractive lens surgery has evolved to include arcuate keratotomy and toric

Management of astigmatism at the time of cataract or refractive lens surgery has evolved to include arcuate keratotomy and toric Management of Astigmatism with the LENSAR Laser System with Streamline Mark Packer Mark Packer MD Consulting, Inc., Boulder, CO, US DOI: https://doi.org/10.17925/usor.2017.12.99 Management of astigmatism

More information

Premium treatment starts with premium diagnosis

Premium treatment starts with premium diagnosis by i-optics Premium treatment starts with premium diagnosis Complete your cataract-refractive platform The premium IOL opportunity Premium IOL market to nearly double in next 5 years 2013 1.6 million 22

More information

Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators

Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators Original Article http://dx.doi.org/10.3349/ymj.2015.56.4.1097 pissn: 0513-5796, eissn: 1976-2437 Yonsei Med J 56(4):1097-1105, 2015 Comparison of the Astigmatic Power of Toric Intraocular Lenses Using

More information

Development of a program for toric intraocular lens calculation. considering posterior corneal astigmatism, incisioninduced

Development of a program for toric intraocular lens calculation. considering posterior corneal astigmatism, incisioninduced DOI 10.1007/s00417-016-3446-3 CATARACT Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective

More information

Irregular Corneal Astigmatism & Cataract

Irregular Corneal Astigmatism & Cataract Costas Karabatsas MD, PhD, MRCOphth, FEBOphth, FRCS Ophth Irregular Corneal Astigmatism & Cataract (assessing ocular surface, IOL selection) In both LRS and Cataract Surgery aim = Emmetropia Refractive

More information

AXsys Study Data and Press Release Reference

AXsys Study Data and Press Release Reference Clinically Tested to be the World s Most Accurate Toric Marking Device Takayuki Akahoshi, MD Tokyo Japan Ophthalmologist Anterior Segment I WORKED WITH ASICO LLC TO DESIGN AN AXsys TM TORIC MARKING DEVICE

More information

DOWNLOAD ASTIGMATIC TECHNIQUE IN ONE STEP RAINBOW HOLOGRAPHY

DOWNLOAD ASTIGMATIC TECHNIQUE IN ONE STEP RAINBOW HOLOGRAPHY ASTIGMATIC TECHNIQUE IN ONE PDF DOWNLOAD 1 / 5 2 / 5 3 / 5 astigmatic technique in one pdf astigmatic technique in one pdf Signs and symptoms. Although astigmatism may be asymptomatic, higher degrees of

More information

Over the last decade, a vast improvement on intraocular

Over the last decade, a vast improvement on intraocular REVIEW Posterior Astigmatism: Considerations for Cataract Refractive Surgery Planning Milton S. Yogi, MD, MBA1 Bruna V. Ventura, MD, PhD2 Eliane M. Nakano, MD3 1 Head, Cataract Department, Beneficência

More information

POST-OPERATIVE ASTIGMATISM AFTER SICS AND PHACOEMULSIFICATION.

POST-OPERATIVE ASTIGMATISM AFTER SICS AND PHACOEMULSIFICATION. 4 POST-OPERATIVE ASTIGMATISM AFTER SICS AND PHACOEMULSIFICATION. Dr.Vijay Damor, Dr.Anupama Mahant, Department of ophthalmology,amc MET Medical college. Ahmedabad pin 380008 Abstract : Background: Astigmatism

More information

2Optimizing the Refractive

2Optimizing the Refractive Chapter 02 3/4/11 4:29 PM Page 1 2Optimizing the Refractive Outcome: Correction of Astigmatism in Cataract Surgery By: Robert M. Kershner, M.D., FACS General Considerations Lens extraction with the implantation

More information

Phacoemulsification: The first 50 Cases

Phacoemulsification: The first 50 Cases Phacoemulsification: The first 5 Cases Aneeq Ullah Baig Mirza*, Samina Jehangir**, Wasif Mohy-ud-din Kadri** * Department of Ophthalmology Islamic International Medical College and Railway Hospital Rawalpindi.

More information

Evaluation of Opposite Clear Corneal Incision in Controlling Astigmatism in Cataract Patients Undergoing Phacoemulsification Surgery

Evaluation of Opposite Clear Corneal Incision in Controlling Astigmatism in Cataract Patients Undergoing Phacoemulsification Surgery Evaluation of Opposite Clear Corneal Incision in Controlling Astigmatism in Cataract Patients Undergoing Phacoemulsification Surgery J.S.Bhalla, Meenakshi Rani, Surbhi Gupta Department of Ophthalmology,

More information

Arthur Cummings FRCSEd

Arthur Cummings FRCSEd How to Improve your Refractive Cataract Surgery Outcomes by Skilful Interpretation of Corneal Mapping Course IC-16 ESCRS Copenhagen 10 th September 2016 Consultant for Alcon / WaveLight/TearLab Arthur

More information

Standard for Reporting Refractive Outcomes of Intraocular Lens Based Refractive Surgery

Standard for Reporting Refractive Outcomes of Intraocular Lens Based Refractive Surgery EDITORIAL Standard for Reporting Refractive Outcomes of Intraocular Lens Based Refractive Surgery Dan Z. Reinstein, MD, MA(Cantab), FRCSC; Timothy J. Archer, MA(Oxon), DipCompSci(Cantab); Sathish Srinivasan,

More information

Index. D DALK, 69, 155 Differential sector index (DSI), 92 Discriminant function analysis, DMEK, 23 Donor factors, 156 DSAEK, 23

Index. D DALK, 69, 155 Differential sector index (DSI), 92 Discriminant function analysis, DMEK, 23 Donor factors, 156 DSAEK, 23 A Abberrometry, intraoperative, 66 Aberrated corneas, topography-guided laser for, 146 Aberration coefficient, 99 corneal, 94 Ablation cylindrical, 131 hyperopic, 130, 131 pattern, design and planning,

More information

2nd ESASO Anterior Segment Academy April 2016, Milano/Italy

2nd ESASO Anterior Segment Academy April 2016, Milano/Italy 2nd ESASO Anterior 28 30 April 2016, Milano/Italy Istituto Clinico Humanitas Humanitas Congress Centre Via Manzoni, 56 20089 Rozzano, Milan Congress Chairmen: José L. Güell, Paolo Vinciguerra www.esaso.org/2nd-esaso-anteriorsegment-academy-2016/

More information

Femtosecond Cataract Surgery: Correction of Astigmatism and Complex Cases Financial Disclosures Femtosecond Laser Utility in Cataract Surgery

Femtosecond Cataract Surgery: Correction of Astigmatism and Complex Cases Financial Disclosures Femtosecond Laser Utility in Cataract Surgery 1 2 3 4 5 6 7 Femtosecond Cataract Surgery: Correction of Astigmatism and Complex Cases Michael J Taravella, MD Director: Cornea and Refractive Surgery University of Colorado Financial Disclosures Consultant

More information

CHANGE ON THE HORIZONTAL AND VERTICAL MERIDIANS OF THE CORNEA AFTER CATARACT SURGERY*

CHANGE ON THE HORIZONTAL AND VERTICAL MERIDIANS OF THE CORNEA AFTER CATARACT SURGERY* 15 Merriam Final 11/9/01 11:22 AM Page 187 CHANGE ON THE HORIZONTAL AND VERTICAL MERIDIANS OF THE CORNEA AFTER CATARACT SURGERY* BY John C. Merriam, MD, Lei Zheng, MD (BY INVITATION), Joanna Urbanowicz,

More information

The efficacy of Toric IOL in comparison to LRI in correcting pre-existing astigmatism in phacoemulsification

The efficacy of Toric IOL in comparison to LRI in correcting pre-existing astigmatism in phacoemulsification Original Research Article The efficacy of Toric IOL in comparison to LRI in correcting pre-existing astigmatism in phacoemulsification Parul Singh 1, Ruchika Agarwal 2*, Sanjeev Rohatgi 2, Malini Vohra

More information

Disclosure. Getting Up to Date with LASIK. Modern advancements LASIK. What we re curing. Changing the corneal surface

Disclosure. Getting Up to Date with LASIK. Modern advancements LASIK. What we re curing. Changing the corneal surface Getting Up to Date with LASIK Disclosure I am not a paid consultant to any drug or device company. Stillwater, MN Adjunct Associate Professor University of Minnesota LASIK Use one instrument to make a

More information

ORIGINAL ARTICLE. Primary Topography-Guided LASIK: Treating Manifest Refractive Astigmatism Versus Topography-Measured Anterior Corneal Astigmatism

ORIGINAL ARTICLE. Primary Topography-Guided LASIK: Treating Manifest Refractive Astigmatism Versus Topography-Measured Anterior Corneal Astigmatism ORIGINAL ARTICLE Primary Topography-Guided LASIK: Treating Manifest Refractive Astigmatism Versus Topography-Measured Anterior Corneal Astigmatism Avi Wallerstein, MD, FRCSC; Mathieu Gauvin, BEng, PhD;

More information

No financial interest

No financial interest Management of high astigmatism after penetrating keratoplasty Ahmed Sherif MD Assistant Professor of Ophthalmology Cairo University No financial interest 1 Incidence Several reports state that 15-31% of

More information

The Short Term Effects of a Single Limbal Relaxing Incision Combined with Clear Corneal Incision

The Short Term Effects of a Single Limbal Relaxing Incision Combined with Clear Corneal Incision pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2010;24(2):78-82 DOI: 10.3341/kjo.2010.24.2.78 Original Article The Short Term Effects of a Single Limbal Relaxing Incision Combined with Clear Corneal

More information

LASIK for post penetrating keratoplasty astigmatism and myopia

LASIK for post penetrating keratoplasty astigmatism and myopia Br J Ophthalmol 1999;83:113 118 113 The Eye Institute, Chatswood, NSW, Australia S K Webber M A Lawless G L Sutton C M Rogers Correspondence to: Dr Michael Lawless, Level 3, 7 Victoria Avenue, Chatswood,

More information

Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent

Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent Journal of the Optical Society of Korea Vol. 17, No. 2, April 2013, pp. 219-223 DOI: http://dx.doi.org/10.3807/josk.2013.17.2.219 Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical

More information

Arcuate Keratotomy for High Postoperative Keratoplasty Astigmatism Performed With the IntraLase Femtosecond Laser

Arcuate Keratotomy for High Postoperative Keratoplasty Astigmatism Performed With the IntraLase Femtosecond Laser Arcuate Keratotomy for High Postoperative Keratoplasty Astigmatism Performed With the IntraLase Femtosecond Laser Luca Buzzonetti, MD; Gianni Petrocelli, MD; Antonio Laborante, MD; Emilio Mazzilli, MD;

More information

Non-penetrating Femtosecond Laser. intrastromal astigmatic keratotomy (ISAK) Patients With Mixed Astigmatism After Previous Refractive Surgery

Non-penetrating Femtosecond Laser. intrastromal astigmatic keratotomy (ISAK) Patients With Mixed Astigmatism After Previous Refractive Surgery ORIGINAL ARTICLE Non-penetrating Femtosecond Laser Intrastromal Astigmatic Keratotomy in Patients With Mixed Astigmatism After Previous Refractive Surgery Jan Venter, MD; Rodney Blumenfeld, MD; Steve Schallhorn,

More information

Irregular Astigmatism Diagnosis And Treatment

Irregular Astigmatism Diagnosis And Treatment Irregular Astigmatism Diagnosis And Treatment 1 / 5 2 / 5 3 / 5 Irregular Astigmatism Diagnosis And Treatment Irregular Astigmatism: Diagnosis and Treatment. Ming Wang, ed., Thorofare, NJ: Slack Inc.;

More information

Assessment & management of irregular astigmatism

Assessment & management of irregular astigmatism Assessment & management of irregular astigmatism Athens, March 2018 D. Epstein, MD, PhD, FARVO No financial interest What is an irregular astigmatism? A question that starts at the wrong end... How about

More information

New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder

New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder ARTICLE New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder Noel Alpins, FRANZCO, FRCOphth, FACS, James K.Y. Ong, BOptom, Dr.rer.nat, George Stamatelatos,

More information

STUDY OF ASTIGMATISM IN SMALL INCISSION CATARACT SURGERY BETWEEN TEMPORAL AND SUPERIOR INCISSIONS K. J. N. Sivacharan 1, G.

STUDY OF ASTIGMATISM IN SMALL INCISSION CATARACT SURGERY BETWEEN TEMPORAL AND SUPERIOR INCISSIONS K. J. N. Sivacharan 1, G. STUDY OF ASTIGMATISM IN SMALL INCISSION CATARACT SURGERY BETWEEN TEMPORAL AND SUPERIOR INCISSIONS K. J. N. Sivacharan 1, G. Hanumantharao 2 HOW TO CITE THIS ARTICLE: K. J. N. Sivacharan, G. Hanumantharao.

More information

Circular Keratotomy to Reduce Astigmatism and Improve Vision in Stage I and II Keratoconus

Circular Keratotomy to Reduce Astigmatism and Improve Vision in Stage I and II Keratoconus Circular Keratotomy to Reduce Astigmatism and Improve Vision in Stage I and II Keratoconus Jorg H. Krumeich, MD; Guy M. Kezirian, MD, FACS ABSTRACT PURPOSE: To report the use of circular keratotomy in

More information

Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery

Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery 접수번호 : 2008-114 Korean Journal of Ophthalmology 2009;23:240-248 ISSN : 1011-8942 DOI : 10.3341/kjo.2009.23.4.240 Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery Yang Kyeung

More information

Clinical outcomes of Transepithelial photorefractive keratectomy to treat low to moderate myopic astigmatism

Clinical outcomes of Transepithelial photorefractive keratectomy to treat low to moderate myopic astigmatism Xi et al. BMC Ophthalmology (2018) 18:115 https://doi.org/10.1186/s12886-018-0775-5 RESEARCH ARTICLE Clinical outcomes of Transepithelial photorefractive keratectomy to treat low to moderate myopic astigmatism

More information

Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism

Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism Original Article Yonsei Med J 216 Nov;57(6):1475-1481 pissn: 513-5796 eissn: 1976-2437 Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High

More information

Clinical results of arcuate incisions to correct astigmatism

Clinical results of arcuate incisions to correct astigmatism Clinical results of arcuate incisions to correct astigmatism Kurt A. Buzard, MD, Eduardo Laranjeira, MD, Bradley R. Fundingsland, BS ABSTRACT Purpose: To evaluate the effectiveness of arcuate incisions

More information

Results of Intraoperative Manual Cyclotorsion Compensation for Myopic Astigmatism in Patients Undergoing Small Incision Lenticule Extraction (SMILE)

Results of Intraoperative Manual Cyclotorsion Compensation for Myopic Astigmatism in Patients Undergoing Small Incision Lenticule Extraction (SMILE) ORIGINAL ARTICLE Results of Intraoperative Manual Cyclotorsion Compensation for Myopic Astigmatism in Patients Undergoing Small Incision Lenticule Extraction (SMILE) Sri Ganesh, MS, DNB; Sheetal Brar,

More information

A R Sebai Sarhan, Harminder S Dua, Michelle Beach

A R Sebai Sarhan, Harminder S Dua, Michelle Beach Br J Ophthalmol 2000;84:837 841 837 Division of Ophthalmology and Visual Sciences, University of Nottingham, University Hospital, Queen s Medical Centre, Nottingham NG7 2UH A R S Sarhan H S Dua M Beach

More information

A novel method for human Astigmatism formulation and measurement

A novel method for human Astigmatism formulation and measurement Available online at http://www.ijabbr.com International journal of Advanced Biological and Biomedical Research Volume 1, Issue 8, 2013: 874-884 A novel method for human Astigmatism formulation and measurement

More information

Effect of Pupil Size on Uncorrected Visual Acuity in Pseudophakic Eyes With Astigmatism

Effect of Pupil Size on Uncorrected Visual Acuity in Pseudophakic Eyes With Astigmatism ORIGINAL ARTICLE Effect of Pupil Size on Uncorrected Visual Acuity in Pseudophakic Eyes With Astigmatism Kazuhiro Watanabe, MD; Kazuno Negishi, MD; Murat Dogru, MD; Takefumi Yamaguchi, MD; Hidemasa Torii,

More information

620 Rejwrts Investigative Ophthalmology

620 Rejwrts Investigative Ophthalmology Rejwrts Investigative Ophthalmology August D. E.: Retinal dystrophy in the rat a pigment epithelial disease, INVEST. OPHTHALMOL. :,. Color vision: blue deficiencies in? ANTHONY J. ADAMS,* RICHARD BAL-

More information

Refractive, anterior corneal and internal astigmatism in the pseudophakic eye

Refractive, anterior corneal and internal astigmatism in the pseudophakic eye Refractive, anterior corneal and internal astigmatism in the pseudophakic eye Jesper F. Bregnhøj, 1,2 Pourang Mataji 1,2 and Kristian Næser 1,2 1 Department of Ophthalmology, Aarhus University Hospital,

More information

Clinical Study Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass Instrument

Clinical Study Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass Instrument BioMed Research International Volume 2013, Article ID 124327, 6 pages http://dx.doi.org/1155/2013/124327 Clinical Study Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass

More information

THE CHALLENGES CORNEAL IRREGULARITIES POST-LASIK ECTASIA IS THIS A GOOD LASIK CANDIDATE? 3/5/2015. FITTING THE IRREGULAR CORNEA Challenges & Solutions

THE CHALLENGES CORNEAL IRREGULARITIES POST-LASIK ECTASIA IS THIS A GOOD LASIK CANDIDATE? 3/5/2015. FITTING THE IRREGULAR CORNEA Challenges & Solutions DISCLOSURE STATEMENT No disclosure statement. CORNEAL IRREGULARITIES Course Title: Lecturer: FITTING THE IRREGULAR CORNEA Challenges & Solutions Phyllis Rakow, COMT, NCLM, FCLSA(H) Keratoconus Pseudokeratoconus

More information

Full-Thickness Astigmatic Keratotomy Combined With Small-Incision Lenticule Extraction to Treat High-Level and Mixed Astigmatism

Full-Thickness Astigmatic Keratotomy Combined With Small-Incision Lenticule Extraction to Treat High-Level and Mixed Astigmatism CLINICAL SCIENCE Full-Thickness Astigmatic Keratotomy Combined With Small-Incision Lenticule Extraction to Treat High-Level and Mixed Astigmatism Bu Ki Kim, MD, MS,* Su Joung Mun, MD, PhD,* Dae Gyu Lee,

More information

AstigmatismamongotherRefractiveErrorsinChildrenofSouthernSriLanka. Astigmatism among other Refractive Errors in Children of Southern Sri Lanka

AstigmatismamongotherRefractiveErrorsinChildrenofSouthernSriLanka. Astigmatism among other Refractive Errors in Children of Southern Sri Lanka : F Diseases Volume 15 Issue 1 Version 1.0 Year 2015 Type: Double Blind Peer Reviewed International Research Journal Publisher: Global Journals Inc. (USA) Online ISSN: 2249-4618 & Print ISSN: 0975-5888

More information

Lin Liu, Jun Zou *, Hui Huang, Jian-guo Yang and Shao-rong Chen

Lin Liu, Jun Zou *, Hui Huang, Jian-guo Yang and Shao-rong Chen Liu et al. Diagnostic Pathology 2012, 7:55 RESEARCH Open Access The influence of corneal astigmatism on retinal nerve fiber layer thickness and optic nerve head parameter measurements by spectral-domain

More information

Orthokeratology (Ortho-K), or corneal refractive therapy, is. Toric Double Tear Reservoir Contact Lens in Orthokeratology for Astigmatism ARTICLE

Orthokeratology (Ortho-K), or corneal refractive therapy, is. Toric Double Tear Reservoir Contact Lens in Orthokeratology for Astigmatism ARTICLE ARTICLE Toric Double Tear Reservoir Contact Lens in Orthokeratology for Astigmatism Jaume Pauné, M.Sc., Genís Cardona, Ph.D., and Lluïsa Quevedo, Ph.D. Objectives: This study aimed at assessing the performance

More information

Dr Noel Alpins AM Digest of Personal and Professional biography

Dr Noel Alpins AM Digest of Personal and Professional biography Dr Noel Alpins AM Digest of Personal and Professional biography Work Address: 7 Chesterville Road Cheltenham 3192 Dr Noel Alpins AM has been specialising in Cataract and Refractive Surgery since founding

More information

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,700 108,500 1.7 M Open access books available International authors and editors Downloads Our

More information

Research conducted over the past 15 years has yielded a

Research conducted over the past 15 years has yielded a Visual Psychophysics and Physiological Optics Longitudinal Change and Stability of Refractive, Keratometric, and Internal Astigmatism in Childhood Erin M. Harvey, 1,2 Joseph M. Miller, 1 3 J. Daniel Twelker,

More information

OPTOMETRY. An analysis of the astigmatic changes induced by accelerated o rt ho ke ratolog y I ORIGINALPAPER 1

OPTOMETRY. An analysis of the astigmatic changes induced by accelerated o rt ho ke ratolog y I ORIGINALPAPER 1 OPTOMETRY I ORIGINALPAPER 1 An analysis of the astigmatic changes induced by accelerated o rt ho ke ratolog y Clin Exp Optom ; 85: 5: 84-93 John Mountford* DipAppSc FAAO FVCO FCLS Konrad Pesudovst PhD

More information

Astigmatic axis and amblyopia in childhood

Astigmatic axis and amblyopia in childhood Astigmatic axis and amblyopia in childhood Maths Abrahamsson and Johan Sjo strand ABSTRACT. Purpose: This study is part of a larger project whose aim is to evaluate the relationship between refractive

More information

Proposed classification for topographic patterns seen after penetrating keratoplasty

Proposed classification for topographic patterns seen after penetrating keratoplasty Br J Ophthalmol 1999;83:403 409 403 Department of Ophthalmology, Bristol Eye Hospital, Bristol C H Karabatsas S D Cook J M Sparrow Correspondence to: Costas H Karabatsas, PO Box 16757, Athens 115 02, Greece.

More information

Analysis of WFS Measurements from first half of 2004

Analysis of WFS Measurements from first half of 2004 Analysis of WFS Measurements from first half of 24 (Report4) Graham Cox August 19, 24 1 Abstract Described in this report is the results of wavefront sensor measurements taken during the first seven months

More information

Astigmatism: analysis and synthesis of the astigmatic ametropia

Astigmatism: analysis and synthesis of the astigmatic ametropia http://eoftalmo.org.br OPINION OF SPECIALISTS Astigmatism: analysis and synthesis of the astigmatic ametropia Astigmatismo: análise e síntese da ametropia astigmática Analysis and synthesis of the astigmatic

More information

Femtosecond laser-assisted astigmatic keratotomy: a review

Femtosecond laser-assisted astigmatic keratotomy: a review Chang Eye and Vision (2018) 5:6 https://doi.org/10.1186/s40662-018-0099-9 REVIEW Open Access Femtosecond laser-assisted astigmatic keratotomy: a review John S. M. Chang Abstract Background: Astigmatic

More information

Astigmatism is a common refractive error 1 and an important. The Changing Profile of Astigmatism in Childhood: The NICER Study

Astigmatism is a common refractive error 1 and an important. The Changing Profile of Astigmatism in Childhood: The NICER Study Clinical and Epidemiologic Research The Changing Profile of Astigmatism in Childhood: The NICER Study Lisa O Donoghue, Karen M. Breslin, and Kathryn J. Saunders School of Biomedical Sciences, University

More information

Diagnosis and Management of Astigmatism

Diagnosis and Management of Astigmatism Diagnosis and Management of Astigmatism Ray George Diagnosis and Management of Astigmatism "This page is Intentionally Left Blank" Diagnosis and Management of Astigmatism Edited by Ray George Published

More information

1. Introduction. Correspondence should be addressed to Edmund Arthur; arthur

1. Introduction. Correspondence should be addressed to Edmund Arthur; arthur Hindawi Publishing Corporation Journal of Ophthalmology Volume, Article ID 989, 7 pages http://dx.doi.org/.//989 Clinical Study Postoperative Corneal and Surgically Induced Astigmatism following Superior

More information

The CV provides complete support for Cataract and Vitreoretinal surgery with four features that enhance usability:

The CV provides complete support for Cataract and Vitreoretinal surgery with four features that enhance usability: The CV-30000 provides complete support for Cataract and Vitreoretinal surgery with four features that enhance usability: Essential Components Fortas Pump Advanced peristaltic pump Advanced Cassette System

More information

1. Standard Equipment Subjective Eye Tester Name of Parts Details of Auxiliary Lenses Measuring Performance...

1. Standard Equipment Subjective Eye Tester Name of Parts Details of Auxiliary Lenses Measuring Performance... Notification Dear Users, Thank you for your purchase of R 2500 Refractor. Please take time to read our user s manual carefully before use. This guarantees you to make full use of this unit and prolongs

More information

Astigmatism: Aberration or ametropia?

Astigmatism: Aberration or ametropia? http://eoftalmo.org.br OPINION OF SPECIALISTS Astigmatism: Aberration or ametropia? Astigmatismo: Aberração ou Ametropia? Astigmatismo: Aberración o ametropía? Sidney Julio Faria e Sousa - Faculdade de

More information

Cycloplegic Refractions of Infants and Young Children: The Axis of Astigmatism

Cycloplegic Refractions of Infants and Young Children: The Axis of Astigmatism Cycloplegic Refractions of Infants and Young Children: The Axis of Astigmatism Velma Dobson,* Anne B. Fulton, f and S. Lawson Sebris* Review of the cycloplegic refractions of all children who were first

More information

CA-800 Tear Module. Rick Gaudenti. Product Manager, Refraction Mar 2017

CA-800 Tear Module. Rick Gaudenti. Product Manager, Refraction Mar 2017 CA-800 Tear Module Rick Gaudenti Product Manager, Refraction Mar 2017 Meibomian Gland Imaging Meibomian Gland [MEIB] Viewing Meibomian Images are displayed in the center of the screen Two types of an adjustable

More information

Handheld Shack Hartmann Wavefront Sensor. Jim Schwiegerling, Ph.D. Department of Ophthalmology and Optical Sciences The University of Arizona

Handheld Shack Hartmann Wavefront Sensor. Jim Schwiegerling, Ph.D. Department of Ophthalmology and Optical Sciences The University of Arizona Handheld Shack Hartmann Wavefront Sensor Jim Schwiegerling, Ph.D. Department of Ophthalmology and Optical Sciences The University of Arizona COLLABORATORS Erin M. Harvey, PhD Velma Dobson, PhD Joseph M.

More information

Astigmatism in Children: Changes in Axis and Amount from Birth to Six Years

Astigmatism in Children: Changes in Axis and Amount from Birth to Six Years Astigmatism in Children: Changes in Axis and Amount from Birth to Six Years Jane Gwiazda, Mitchell Scheiman,* Indra Mohindra, and Richard Held Noncycloplegic refractions of, children aged - years revealed

More information

ORIGINAL ARTICLE. Corneal and Refractive Error Astigmatism in Singaporean Schoolchildren: a Vector-Based Javal s Rule

ORIGINAL ARTICLE. Corneal and Refractive Error Astigmatism in Singaporean Schoolchildren: a Vector-Based Javal s Rule 1040-5488/01/7812-0881/0 VOL. 78, NO. 12, PP. 881 887 OPTOMETRY AND VISION SCIENCE Copyright 2001 American Academy of Optometry ORIGINAL ARTICLE Corneal and Refractive Error Astigmatism in Singaporean

More information

Multicolor Scan Laser Photocoagulator MC-500 Vixi

Multicolor Scan Laser Photocoagulator MC-500 Vixi Multicolor Scan Laser Photocoagulator MC-500 Vixi MC-500 The Versatile Laser Photocoagulator Selectable configuration of laser colors and delivery units Multiple scan patterns Enhanced usability LPM (Low

More information

CSE 8 th Edition Name-Year System

CSE 8 th Edition Name-Year System The UNB Writing Centre 16/17 C. C. Jones Student Services Centre 26 Bailey Drive, Box 4400 Fredericton, NB Canada, E3B 5A3 Contact us: Phone:(506) 453-4527 (506) 452-6346 Email: wss@unb.ca CSE 8 th Edition

More information

How to Chose an Ideal High Definition Endoscopic Camera System

How to Chose an Ideal High Definition Endoscopic Camera System How to Chose an Ideal High Definition Endoscopic Camera System Telescope Laparoscopy (from Greek lapara, "flank or loin", and skopein, "to see, view or examine") is an operation performed within the abdomen

More information

Instructions to Authors

Instructions to Authors Instructions to Authors European Journal of Psychological Assessment Hogrefe Publishing GmbH Merkelstr. 3 37085 Göttingen Germany Tel. +49 551 999 50 0 Fax +49 551 999 50 111 publishing@hogrefe.com www.hogrefe.com

More information

Characterization and improvement of unpatterned wafer defect review on SEMs

Characterization and improvement of unpatterned wafer defect review on SEMs Characterization and improvement of unpatterned wafer defect review on SEMs Alan S. Parkes *, Zane Marek ** JEOL USA, Inc. 11 Dearborn Road, Peabody, MA 01960 ABSTRACT Defect Scatter Analysis (DSA) provides

More information

Relationships Between Quantitative Variables

Relationships Between Quantitative Variables Chapter 5 Relationships Between Quantitative Variables Three Tools we will use Scatterplot, a two-dimensional graph of data values Correlation, a statistic that measures the strength and direction of a

More information

in the Howard County Public School System and Rocketship Education

in the Howard County Public School System and Rocketship Education Technical Appendix May 2016 DREAMBOX LEARNING ACHIEVEMENT GROWTH in the Howard County Public School System and Rocketship Education Abstract In this technical appendix, we present analyses of the relationship

More information

Relationships. Between Quantitative Variables. Chapter 5. Copyright 2006 Brooks/Cole, a division of Thomson Learning, Inc.

Relationships. Between Quantitative Variables. Chapter 5. Copyright 2006 Brooks/Cole, a division of Thomson Learning, Inc. Relationships Chapter 5 Between Quantitative Variables Copyright 2006 Brooks/Cole, a division of Thomson Learning, Inc. Three Tools we will use Scatterplot, a two-dimensional graph of data values Correlation,

More information

ORIGINAL ARTICLE. Amblyopia in Astigmatic Infants and Toddlers

ORIGINAL ARTICLE. Amblyopia in Astigmatic Infants and Toddlers 1040-5488/10/8705-0330/0 VOL. 87, NO. 5, PP. 330 336 OPTOMETRY AND VISION SCIENCE Copyright 2010 American Academy of Optometry ORIGINAL ARTICLE Amblyopia in Astigmatic Infants and Toddlers Velma Dobson*,

More information

How to Manage Color in Telemedicine

How to Manage Color in Telemedicine [ Document Identification Number : DIN01022816 ] Digital Color Imaging in Biomedicine, 7-13, 2001.02.28 Yasuhiro TAKAHASHI *1 *1 CANON INC. Office

More information

Human Hair Studies: II Scale Counts

Human Hair Studies: II Scale Counts Journal of Criminal Law and Criminology Volume 31 Issue 5 January-February Article 11 Winter 1941 Human Hair Studies: II Scale Counts Lucy H. Gamble Paul L. Kirk Follow this and additional works at: https://scholarlycommons.law.northwestern.edu/jclc

More information

Blueline, Linefree, Accuracy Ratio, & Moving Absolute Mean Ratio Charts

Blueline, Linefree, Accuracy Ratio, & Moving Absolute Mean Ratio Charts INTRODUCTION This instruction manual describes for users of the Excel Standard Celeration Template(s) the features of each page or worksheet in the template, allowing the user to set up and generate charts

More information

Onset and Progression of With-the-Rule Astigmatism in Children with Infantile Nystagmus Syndrome

Onset and Progression of With-the-Rule Astigmatism in Children with Infantile Nystagmus Syndrome Visual Psychophysics and Physiological Optics Onset and Progression of With-the-Rule Astigmatism in Children with Infantile Nystagmus Syndrome Jingyun Wang, Lauren M. Wyatt, Joost Felius,, David R. Stager,

More information

*Please note that although this product has been approved in Japan, its launch in other countries has not yet been confirmed.

*Please note that although this product has been approved in Japan, its launch in other countries has not yet been confirmed. make News & Information 1-7-1 Konan, Minato-ku, Tokyo 108-0075, Japan Sony Corporation No.13-085E July 23, 2013 Sony Introduces head-mount image processing unit for endoscopic image display - Images from

More information

Eyes with regular astigmatism have two orthogonal focal. Accommodation in Astigmatic Children During Visual Task Performance

Eyes with regular astigmatism have two orthogonal focal. Accommodation in Astigmatic Children During Visual Task Performance Clinical and Epidemiologic Research Accommodation in Astigmatic Children During Visual Task Performance Erin M. Harvey, 1,2 Joseph M. Miller, 1 3 Howard P. Apple, 1 Pavan Parashar, 4 J. Daniel Twelker,

More information

Treatment of astigmatism-related amblyopia in 3- to 5-year-old children

Treatment of astigmatism-related amblyopia in 3- to 5-year-old children Vision Research 44 (2004) 1623 1634 www.elsevier.com/locate/visres Treatment of astigmatism-related amblyopia in 3- to 5-year-old children Erin M. Harvey a, *, Velma Dobson a,b, Joseph M. Miller a,c,d,

More information

1. MORTALITY AT ADVANCED AGES IN SPAIN MARIA DELS ÀNGELS FELIPE CHECA 1 COL LEGI D ACTUARIS DE CATALUNYA

1. MORTALITY AT ADVANCED AGES IN SPAIN MARIA DELS ÀNGELS FELIPE CHECA 1 COL LEGI D ACTUARIS DE CATALUNYA 1. MORTALITY AT ADVANCED AGES IN SPAIN BY MARIA DELS ÀNGELS FELIPE CHECA 1 COL LEGI D ACTUARIS DE CATALUNYA 2. ABSTRACT We have compiled national data for people over the age of 100 in Spain. We have faced

More information

OPTOMETRY INVITED REVIEW. A review of astigmatism and its possible genesis

OPTOMETRY INVITED REVIEW. A review of astigmatism and its possible genesis C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY INVITED REVIEW A review of astigmatism and its possible genesis Clin Exp Optom 2007; 90: 1: 5 19 Scott A Read PhD Michael J Collins PhD Leo G Carney

More information

Mental Health Status and Perceived Tinnitus Severity

Mental Health Status and Perceived Tinnitus Severity Mental Health Status and Perceived Tinnitus Severity Steven L. Benton, Au.D. VA M edical Center D ecatur, GA 30033 steve.benton@va.gov Background: Relevance Veterans Benefits Administration (2012): Tinnitus

More information

How to Talk with Your Doctor About Music During Surgery (or other medical or dental procedures)

How to Talk with Your Doctor About Music During Surgery (or other medical or dental procedures) How to Talk with Your Doctor About Music During Surgery (or other medical or dental procedures) Don't wait! If you or a loved one are planning to have a medical procedure now or in the future, you MUST

More information