General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications Model PR300 Power and Energy Meter GS 77C01E01-01E Oeriew This panel-monted power and energy meter with a large, three-row ED display integrates all the measring fnctions reqired for power management in locations sch as factories and bildings into a single nit. With the objectie of woring toward the preseration of the global enironment by saing energy and performing eqipment maintenance, the PR300 is designed to display and otpt the energy of arios types of electrical eqipment. Featres Saes on cost, wiring, and space Integrates a wide selection of fnctions for measring things lie energy (actie, regeneratie, reactie, and apparent), power (actie, regeneratie, reactie, and apparent), oltage, crrent, freqency, and power factor into a single nit. Employs a large, three-row ED display Capable of displaying three-phase crrent and oltage simltaneosly, and the measrement items yo assign. Analog otpt fnction Eqipped with a transdcer fnction for power (actie, regeneratie, reactie, and apparent), oltage, crrent, freqency, and power factor (4 to ma DC). Demand measrement Measres the aerage power and crrent within a specified period. It also allows yo to set p alarm points to otpt alarms. Eqipped with a mltitde of fnctions Enables measrement of the maximm and minimm ales of oltage and the maximm ale of crrent, as well as, for example, the se of external digital inpt to measre energy at arbitrary times. Plse otpt Capable of otptting plses proportional to energy (one measrement item from actie, regeneratie, reactie, and apparent energy). Conerts the phase and wire system of an AC power system and an inpt oltage circit to a niersal format The PR300 can handle from the single-phase two-wire system and single-phase three-wire system to the threephase three-wire system and three-phase for-wire system, and also niersally cope with inpt oltage circits p to 600 AC. Compatible with ANSI 4-inch rond form size and DIN 96-sqare instrment size The ability to attach and detach JIS/ANSI-monting it maes the PR300 compatible with panel ctots of ANSI 4- inch rond form, JIS 0-sqare instrment size, and DIN 96-sqare instrment size. Standard eqipped with an RS-485 commnication fnction and capable of Ethernet commnication Compatible with oerseas reqirements Power line indications A, B, and C proided for oerseas se, in addition to R, S, and T ANSI 4-inch rond form size The ability to attach and detach JIS/ANSI-monting it ensres compatibility with two sizes. Model and Sffix Codes PR300-0 Model Phase and wire system 3: niersal three-phase three-wire system (single-phase two-wire, single-phase three-wire, and three-phase three-wire systems) 4: niersal three-phase for-wire system (single-phase two-wire, single-phase three-wire, three-phase three-wire, and three-phase for-wire systems) 5: Three-phase for-wire system (2.5 element)* 1 Inpt oltage/inpt crrent 1: niersal oltage inpt* 2 (0, 300, 600 ) / 1 A AC 2: niersal oltage inpt* 2 (0, 300, 600 ) / 5 A AC Additional inpt and otpt fnction 0: 1 digital inpt 1: 1 digital inpt, 1 analog otpt 2: 1 digital inpt, 1 plse otpt 3: 1 digital inpt, 1 analog otpt, 1 plse otpt Commnication fnction 0: RS-485 commnication 3: RS-485 commnication, Ethernet commnication* 3 Optional measring fnction 0: None 3: Demand measrement (1 demand alarm otpt) 6: AC 10% (50/60 Hz) or DC % Phase indication format A: A, B, and C indications R: R, S, and T indications *1 Can be sed only when the oltage is in a state of eqilibrim. The phase and wire system cannot be changed. *2 Set the oltage range (0, 300, or 600 ) according to the rated inpt oltage to be measred. (Refer to Rated Inpt oltage of the Inpt Specifications on page 6.) *3 For Ethernet commnication, the RS-485 commnication interface is exclsiely for the Ethernet-serial gateway fnction. Ordering Information Specify the model and sffix codes. Example: PR A-0 nder application for approal DIN 96-sqare instrment size GS 77C01E01-01E Copyright Feb. 06 1st Edition Feb. 06

2 2 Measring Fnctions Measrement item Single-phase Single-phase Three-phase Three-phase Three-phase nit and two-wire three-wire three-wire for-wire for-wire system system system system system (2.5 element) * 3 symbol Remars Actie energy () * 1 Wh, MWh Actie energy () * 1 Wh, MWh Regeneratie energy Reactie energy () * 1 * 4 arh, Marh AG: Reactie energy () * 1 * 4 arh, Marh EAD: Apparent energy * 1 * 4 Ah, MAh Optional actie energy * 1 Wh Actie power Maximm W, W, MW Minimm Reactie power Maximm *4 ar, ar, Mar Minimm Apparent power Maximm *4 A, A, MA Minimm oltage-1 Maximm, Minimm oltage-2 Maximm, Minimm oltage-3 Maximm, Minimm Crrent-1 Maximm * 4 A, A Crrent-2 Maximm A, A Crrent-3 Maximm * 4 A, A Freqency Calclated from the Maximm Hz oltage-1 Minimm Power factor Maximm * 4 AG: COS EAD: Minimm Demand crrent-1 Demand Maximm * 4 * 4 A Demand crrent-2 Demand A Maximm A Demand crrent-3 Demand * 4 A Maximm * 4 A * Demand power 2 Maximm W Demand W Demand crrent * 2 *1 Integrated low-ct power can be set for each energy. Integrated low-ct power: This is a fnction for not integrating power less than a set ale as energy. The setting range of integrated low-ct power is 0.05 to.00% of the rated power (initial ale: 0.05%). *2 Either demand power or demand crrent can be set as a measrement item. *3 Can be sed only when the oltage is in a state of eqilibrim. *4 Can be measred only when the crrent is in a state of eqilibrim. : Effectie : Ineffectie All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

3 3 Optional integrating fnction Power is integrated while a control signal for optional integration is on. When the control signal is switched from off to on, the optional integrated ale indication is reset and integration starts. (The integrated ale prior to the reset is held in a register.) The integrated ale cannot be garanteed in the eent of a power failre occrring dring integration. Demand measrement (when demand measrement is specified) The PR300 measres aerage power or aerage crrent within a set demand period. The maximm demand ale for the demand measring time is held ntil the power is trned off, remote reset is exected, or the next demand measrement is started. Item Setting Range Resoltion Initial ale Remars Demand power/crrent Actie power, crrent Actie power Demand period 1 to 60 mintes (Demand alarm mas time to 60 mintes) 1 minte 30 mintes Demand alarm mas time Demand period Demand alarm mas time* 1 minte to length of demand period 1 minte 1 minte Demand power alarm point 1 to 1000 W 1 W 100 W When demand power is selected Demand crrent alarm point 1 to 1000 A 1 A 100 A When demand crrent is selected Alarm release fnction Atomatic release and Atomatic manal release release Data pdate interal 10 seconds * This is the time from the start of the demand period to the set time in which no jdgment is made for the alarm (alarm mased). Dring the alarm mas time, no maximm demand ale is pdated and no alarm is otpt. Start demand measment Demand period (1 period) Stop demand measment Aerage power Aerage power (crrent) pdate (crrent) pdate Demand measring time The maximm demand ale for this time is held. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

4 4 Display and Operation Specifications (6) (7) (8) (9) (1) (5) (10) () (2) pper display (3) Middle display (4) ower display () (1) Measred ale Display <Contined on the following page> 5-digit, 3-row, 7-segment ED display Display color: red Measred ale display: Measrement Item Display Actie energy [Wh, MWh] *1 Reactie energy [arh, Marh] *2 Apparent energy [Ah, MAh] *1 Regeneratie energy [Wh, MWh] *2 Optional actie energy [Wh] Actie/regeneratie power (instantaneos, maximm, and minimm ales) [W, W, MW] *2, *3 Reactie power (instantaneos, maximm, and minimm ales) [ar, ar, Mar] *2, *3 Apparent power (instantaneos, maximm, and minimm ales) [A, A, MA] *1, *3 oltage (instantaneos, maximm, and minimm ales) [, ] *1, *3 Crrent (instantaneos and maximm ales) [A, A] *2, *4 Power factor (instantaneos, maximm, EAD: d [COS] and minimm ales) AG: G [COS] *3 Freqency (instantaneos, maximm, and minimm ales) [Hz] *3 Demand power Maximm demand power [W] [DEMAND] *4 Demand crrent Maximm demand crrent [A] [DEMAND] *4 *1: Withot sign, bt with a decimal point *2: With a sign and a decimal point ("+" is not indicated). Regeneratie power (energy) always shows negatie indication. The position of a decimal point differs depending on the primary rated power, T ratio, and ratio. *3: "MAX" lights p for the maximm ale and "MIN" lights p for the minimm ale. *4: "MAX" lights p for the maximm ale. Measred ale screen: Display pattern: The measrement items yo want to display are assigned to each of the pper, middle, and lower displays to proide indications sing three display rows as one pattern. p to eight display patterns can be set. The initial ales are as shown in the following table. (Combinations other than those shown in the following table are also aailable if the parameters are set.) Nmber of display patterns: Can be set in the range of 1 to 8. Pressing the SET/ENT ey switches the display from "display pattern-1," "display pattern-2," and so on in order according to the nmber of patterns set. The initial ale is "1" and only display pattern 1 is displayed when this ale is set. Display Pattern-1 Display Pattern-2 Display Pattern-3 Display Pattern-4 Display Pattern-5 Display Pattern-6 Display Pattern-7 Display Pattern-8 pper display Middle display ower display Crrent (Phase switch indication)* oltage (Phase switch indication)* Actie power Actie energy Reactie power Actie power Power factor AG reactie energy Apparent energy Crrent-1 Crrent-2 Crrent-3 oltage-1 oltage-2 oltage-3 Crrent (Phase switch indication)* oltage (Phase switch indication)* Freqency Crrent (Phase switch indication)* Actie power Power factor Actie power Maximm demand ale Demand ale * The display of crrent (phase switch indication) is switched between crrent-1, crrent-2, and crrent-3 each time the SE ey is pressed. The display of oltage (phase switch indication) is switched between oltage-1, oltage-2, and oltage-3 each time the SE ey is pressed. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

5 5 T ratio/ ratio: If the T ratio and ratio are set, inpt to the PR300 is displayed after conerting it to the primary inpt ale before T or. The T and ratios can be set ia commnication or sing the operation eys. T ratio setting range: 1 to 6000* ratio setting range: 0.05 to 300* * Set the T ratio and ratio so that [secondary rated power] [T ratio] [ ratio] is smaller than 10 GW. (2) nit amps The releant nit lamp lights p according to a measrement item and measred ale. Display color: red (3) MAX and MIN amps Either the MAX or MIN lamp lights p when a maximm or minimm measred ale is displayed. Display color: red (4) Phase Indication amps Indicate the phase to which the measred ale corresponds. (The A, B, and C indications or R, S, and T indications shold be specified in accordance with the sffix code.) Display color: red Phase and Wire System oltage-1 oltage-2 oltage-3 Crrent-1 Crrent-2 Crrent-3 Single-phase two-wire system A (R) A (R) Single-phase three-wire system A, B (R, S) B, C (S, T) A (R) C (T) Three-phase three-wire system A, B (R, S) B, C (S, T) A (R) C (T) Three-phase for-wire system A (R) B (S) C (T) A (R) B (S) C (T) Three-phase for-wire system (2.5 element) A (R) C (T) A (R)* C (T)* * Can be measred only when the crrent is in a state of eqilibrim. (5) Power amp ights p when power is spplied. Blins (4 times/sec) ntil it retrns to normal when the commnication error occrs. Display color: green (6) Commnication amp Blins dring commnication (RS-485 or Ethernet). Display color: green (7) Plse Otpt amp ights p when otpt is prodced dring plse otpt, and goes ot when no otpt is prodced. Display color: green (8) Demand Alarm amp If a demand ale exceeds the demand alarm point at a time other than dring the alarm mas time, the OER lamp lights p to indicate the occrrence of an alarm. Display color: red (9) Phase and Wire The lamps of the phase and wire system that hae been set light p. System amps Display color: green (10) Inpt Range amps The inpt oltage range (0, 300, or 600 ) and inpt crrent range (1 A or 5 A) that hae been set light p. Display color: green () DEMAND amp ights p when a demand ale is displayed. Display color: red () Operation Keys sed to switch measred ale display patterns. This ey is also sed for setting parameters. sed to adjst the display digit dring energy indication. This ey is also sed for setting parameters. sed to display the maximm or minimm measred ale. These eys are also sed for setting parameters. Indicator-ot Mode Setting A/D Sampling Rate, Data pdate Interal sed to switch phase indications when the PR300 displays a oltage or crrent for which phase indication can be changed. (Phase switch indication is not aailable for single-phase two-wire system.) This ey is also sed for setting parameters. sed to start/stop demand measrement. The lamp in the ey lights p dring demand measrement. Display color: green This fnction trns off EDs after a certain time elapses, with the exception of the power lamp (ED). The ON/OFF setting of the indicator-ot mode fnction and the wait time before entering the indicator-ot mode can be set sing the operation eys. (Cannot be set ia commnication.) Indicator-ot mode: ON/OFF (initial ale: OFF) Indicator-ot mode wait time: 1 to 60 mintes (resoltion: 1 minte) (initial ale: 10 mintes) A/D sampling rate: 4.8 Hz Internal measrement data: display/commnication data is pdated at an interal of 1 second or less All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

6 6 Inpt Specifications Phase and Wire System Freqency Rated Inpt oltage niersal three-phase three-wire system (switch the setting from single-phase two-wire system, single-phase three-wire system, or three-phase three-wire system) niersal three-phase for-wire system (switch the setting from single-phase two-wire system, single-phase three-wire system, three-phase three-wire system, or three-phase for-wire system) Three-phase for-wire system (2.5 element) 45 to 65 Hz Rated oltage oltage Range (ariable) Allowable Inpt oltage Rated Inpt Crrent Rated Crrent Crrent Range (Fixed) 1 A 1 A 5 A 5 A Allowable Inpt Crrent 1.2 times the crrent range (continos) Twice the crrent range (10 seconds) or 10 times the crrent range (3 seconds) Rated Inpt Power and Measring Range (Secondary side of T and if T and are sed) Single-phase two-wire system Inpt (AC) 0/1A 0/5A 240/1A 240/5A 480/1A 480/5A Rated Power 100 W 500 W 0 W 1000 W 400 W 00 W Inpt Measring Range 0 to 0 W 600 to 600 W 240 to 240 W 00 to 00 W 480 to 480 W 2400 to 2400 W Three-phase three-wire system Inpt (AC) 0/1A 0/5A 240/1A 240/5A 480/1A 480/5A Rated Power 0 W 1000 W 400 W 00 W 800 W 4000 W Inpt Measring Range 240 to 240 W 00 to 00 W 480 to 480 W 2400 to 2400 W 960 to 960 W 4800 to 4800 W Approximate Consmed A oltage Side Crrent Side 0.2 A 0.4 A 0.2 A 0.8 A Approximate Consmed A oltage Side 0.2 A/ phase 0.4 A/ phase 0.8 A/ phase Crrent Side 0.2 A/ phase Single-phase three-wire system Inpt (AC) 240 / 1 A 240 / 5 A Three-phase for-wire system Inpt (AC) 0 / 1 A 0 / 5 A 240 / 1 A 240 / 5 A 480 / 1 A 480 / 5 A Rated Power 0 W 1000 W Rated Power 300 W 00 W 600 W 3000 W 00 W 6000 W Inpt Measring Range 240 to 240 W 00 to 00 W Inpt Measring Range 360 to 360 W 1800 to 1800 W 7 to 7 W 3600 to 3600 W 1440 to 1440 W 70 to 70 W Approximate Consmed A oltage Side Crrent Side 0.2 A/ 0.2 A/ phase phase Approximate Consmed A oltage Side 0.2 A/ phase 0.4 A/ phase 0.8 A/ phase Crrent Side 0.2 A/ phase Inpt measring range if T and are sed The primary inpt power is smaller than 10 GW and the ale calclated by the following eqation is within the inpt measring range mentioned aboe. Inpt measring range (W) = Primary inpt power (W) T ratio ratio Digital Inpt Specifications For digital inpt, either the optional integration start/stop or the demand alarm release can be sed. If demand measrement is specified for an optional measring fnction, digital inpt enters demand alarm release stats. In this case, the optional integration start/stop cannot be sed. Control signal for optional integration Fnction Starts or stops optional integration. Nmber of Inpts 1 Inpt Signal oltage signal* ON signal: 4.5 to DC OFF signal: within 1 DC * A special order can be placed for no-oltage contact. Note: Optional integration control is also possible ia commnication. Once control is performed ia digital inpt, only digital inpt-based control is aailable. Commnication-based control is no longer possible ntil the power is trned off or remote reset is exected. Demand alarm release (when demand measrement is specified) Fnction Cancels demand alarm. Nmber of Inpts 1 Inpt Signal oltage signal* ON signal:4.5 to DC OFF signal: within 1 DC * A special order can be placed for no-oltage contact. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

7 7 Analog Otpt Specifications (When Analog Otpt is Specified) Fnction Conerts measrement data into DC crrent for otpt. Measrement Item for Otpt One item selected from actie power, reactie power, apparent power, oltage (1 to 3), crrent (1 to 3), power factor, and freqency Otpt Signal 4 to ma DC Otpt Accracy Measrement accracy of measrement item for otpt (0.5% of F.S.) Allowable oad Resistance 0 to 600 Response speed 2 seconds or less (ntil 1% of the final ale is reached) Setting Item Measrement item for otpt and the pper and lower limits of scaling. Initial ale: actie power (W), lower limit of scaling: 50% (0 W), pper limit of scaling: 100% (maximm ale of the inpt measring range W) Scaling setting condition: pper limit of scaling lower limit of scaling 50% pper and ower imits Actie power rated power (W) to rated power (W) of Scaling Setting Reactie power rated power (ar) to rated power (ar) Range for Apparent power 0 to rated power (A) Each Measrement Item oltage (1 to 3) 0 to rated oltage () for Otpt Crrent (1 to 3) 0 to rated crrent (A) Power factor 0.5 to 1 to 0.5 Freqency 45 to 65 (Hz) Plse Otpt Specifications (When Plse Otpt is Specified) Fnction Otpts plses proportional to energy. Measrement Item for Otpt One item selected from actie energy, regeneratie energy, reactie energy (EAD, AG), and apparent energy Nmber of Otpts 1 Otpt Signal Open collector Contact Capacity 30 DC at 0 ma Plse nit 0.1 to Wh/plse* (set in 100 Wh increments) Setting Item Measrement item for otpt, plse nit, and ON plse width Initial ale: actie energy (Wh), plse nit: 1 Wh/plse, and ON plse width: 50 ms ON Plse Width Represents the ON time of plses to be otpt. (Set the plse width so that the maximm ON plse width obtained by the following eqation is not exceeded.) Within the range of 10 to 70 ms (set in 10 ms increments) Plse nit [Wh/plse]* Maximm ON plse width (ms) = Secondary rated power [W] T ratio ratio * The nits are arh/plse for reactie energy and Ah/plse for apparent energy. Demand Alarm Otpt Specifications (When Demand Measrement is Specified) Fnction Otpt Signal Contact Capacity Alarm Release Fnction Otpts an alarm if the measred demand ale exceeds the set demand alarm point. Open collector 30 DC at 0 ma Atomatic release: Cancels the alarm if demand falls below the demand alarm point when the next measrement is performed. Manal release*: Holds the stats of an alarm that occrred once. Cancel the alarm ia digital inpt or commnication, or sing the operation eys. * Refer to Demand alarm release of the Digital Inpt Specifications. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

8 8 Commnication Specifications RS-485 commnication Example: PC Maximm commnication distance: 00 m Maximm nmber of slae stations to be connected: 31 Station nmber 01 Station nmber 02 Station nmber 31 Fnction RS-485 commnication enables yo to se the command response method to read a ariety of measrements and write arios settings. Protocol PC lin (with checsm, withot checsm), Modbs (RT, ASCII) Transmission Distance Approx. 00 m maximm (when 24 AWG twisted-pair cable is sed) Connection Method Mlti-drop connection (a maximm of 32 nits [inclding a higher-leel deice]) Station Nmber 01 to 99 (maximm nmber of nits to be connected: 31 [nmber of nits that can be connected to a PC etc.]) (Setting range: 01 to 31 is recommended) Transmission Method Half-dplex commnication Synchronization Method Start-stop synchronization Bad Rate 0, 9600, and 2400 bps Xon/Xoff Control None Data Format Data length 8 bits, 7 bits Parity None, een, odd Stop bit 1 bit, 2 bits For details, refer to the ser s manal for commnications of each deice to be connected. Example of Connection Diagram Approx. 00 m maximm (31 nits maximm) RS-232C straight cable M2 Conerter (Yoogawa) PR300 PR300 PR300 0 (bilt-in) (A) (B) (SG) RS-485 (A)(B) (SG) RS-485 (A) (B) (SG) RS-485 (TERM)(A)(B)(SG) PC * * 0 Ω (external resistor) se the external resistor withot sing the bilt-in resistor of M2. Terminator (FG) Notes: The PR300 employs a two-wire system for RS-485 commnication. SG: The SG terminal is connected to match the signal leel of the RS-485 commnication line. FG: All shielded wires mst be connected and then gronded at one place to proide noise protection for RS-485 commnication lines. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

9 9 Ethernet commnication (when the Ethernet commnication fnction is specified) Example: PC IP address: HB Ethernet AN connection Station nmber 01 IP address: Station nmber 01 IP address: Station nmber 01 IP address: Station nmber 01 IP address: Fnction Ethernet commnication enables yo to se the command response method to read a ariety of measrements and write arios settings. The PR300 can be connected to IEEE802.3 compliant networs (10BASE-T/100BASE-TX). Application layer Transport layer Networ layer Data lin layer Physical layer Higher-leel deice (PC etc.) MODBS/TCP TCP, DP IP, ICMP, ARP Ethernet 10BASE-T/100BASE-TX Commnication Protocol Modbs/TCP Specifications Access Control CSMA/CD Bad Rate 10Mbps/100Mbps Maximm Segment ength 100 m (distance between the hb and modle) Maximm Connecting Maximm of 4 leels of cascading (for 10BASE-T) or maximm of 2 leels of cascading (for 100BASE-TX) Configration (Nmber of hbs that can be cascade connected) IP Address Modbs/TCP Fnction Oeriew of Modbs/TCP Protocol IP addresses can be set sing the operation eys on the front of the PR300. Code Fnction Description 03 Reads data from mltiple D registers Capable of reading data from p to 64 registers continosly. 06 Writes data into D register Capable of writing data into one register. 08 Performs loopbac test Capable of performing a commnication test. 16 Writes data into mltiple D registers Capable of writing data into p to 32 registers continosly. The Modbs/TCP protocol is configred as follows: MBAP Header Fnction code PD Data The MBAP header (Modbs Application Protocol Header) contains the following seen bytes: Byte No Description Transaction ID Protocol ID Nmber of bytes nit ID PD (Simple Protocol Data nit) is the same as Modbs/RT (serial commnication based Modbs protocol). Transaction ID: Set any ale for identifying the transaction. The PR300 retrns a ale receied from a higher-leel deice as a response. Protocol ID: Specify "0" for the Modbs/TCP protocol. Nmber of bytes: Nmber of bytes after the nit ID (byte nmber 6) nit ID: The PR300 retrns a ale receied from a higher-leel deice as a response. Ethernet- Serial Gateway Fnction The PR300 has an RS-485 commnication terminal in addition to an Ethernet commnication connector. Modbs/TCP commands receied by Ethernet are relayed to the RS-485 terminal. This enables the PR300 to connect to a deice with an RS-485 commnication fnction (Modbs/RT protocol) ia a networ. Example: Higher-leel deice IP address: (arbitrary) Ethernet 10BASE-T/100BASE-TX RS-485 commnication Protocol Modbs/RT Bad Rate 9600 bps Parity Een, odd, or none Stop Bit 1 bit Data ength 8 bits PR300 (with Ethernet commnication fnction) RS-485 connection Station nmber 01 (fixed) IP address: (arbitrary) Deice with RS-485 serial commnication fnction Power Monitor of POWERCERT series Digital indicating controller of GREEN series Signal conditioner of JXTA series Station nmber 02 (arbitrary) Station nmber 10 (arbitrary) For details, refer to the ser s manal for commnications of each deice to be connected. Note: If Ethernet commnication is sed, the RS-485 commnication interface is sed specifically for the Ethernet-serial gateway fnction. Therefore, it is not possible for a higher-leel deice sch as a PC to access the PR300 ia the RS-485 commnication interface. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

10 10 Standard Performance Accracy Rating Calclation Accracy Bacp pon Power Failre Inslation Resistance Withstand oltage Implse Withstand oltage Effects of Magnetic Field Effects of Changes in Ambient Temperatre Effects of Power Spply oltage ariations Effects of Inpt Freqency Dstproof and Dripproof Power Spply Power Consmption Actie energy/optional actie energy (Wh) Actie power (W) oltage () Crrent (A) Freqency (Hz) Demand 0.5% (EN60687 accracy: class 0.5 or eqialent) 0.5% of F.S. 0.% of F.S. (oltage rms) 0.% of F.S. (crrent rms) 0.5Hz 0.5% The ale is calclated to an accracy of 1 digit from the measred ale for reactie energy, apparent energy, reactie power, apparent power, power factor or crrent*. * Crrent is only for the 2.5 element measrement. The last integrated ales obtained immediately before the power failre are held for actie energy, regeneratie energy, reactie energy, and apparent energy. Between each of the oltage inpt, crrent inpt, power, 100 M or more (at 500 DC) grond, digital inpt, plse otpt, analog otpt, commnication otpt, and alarm otpt terminals Between each of the oltage inpt, crrent inpt, power, and 00 AC for one minte grond terminals: Between (the oltage inpt, crrent inpt, power and grond 00 AC for one minte terminals) and the digital inpt, plse otpt, analog otpt, alarm otpt, RS-485 commnication otpt, and Ethernet commnication otpt terminals: Between each of the digital inpt, plse otpt, analog otpt, 1000 AC for one minte alarm otpt, and (RS-485 commnication otpt, Ethernet commnication otpt) terminals: Between the RS-485 commnication otpt, and Ethernet 500 AC for one minte commnication otpt terminals: Between all of the oltage inpt, crrent inpt, and power terminals and the grond terminal: Between all of the otpt and grond terminals and all of the oltage inpt and crrent inpt terminals: 6 (1.2/50s), 10 times for positie and negatie Within accracy range at 400 A/m or less 0.01%/ C for a temperatre change rate of 10 C/h or less (when 0.05 In I I max, power factor = 1) 0.02%/ C for a temperatre change rate of 10 C/h or less (when 0.1 In I I max, power factor = AG 0.5) In: rated crrent, I: present crrent inpt 0.05% for ariations within the power spply operating range (when 0.01 In and power factor = 1) In: rated crrent 0.1% for a ariation of 5% (when power factor = 1 and AG 0.5) IP5X AC 10% (50/60 Hz) or DC % AC drie: 10 A maximm, DC drie: 5 W maximm Safety and EMC Standards Safety Standards Measrement category Compliant with IEC/EN nder application for approal 600 CAT. III Measrement Category CAT.I CAT.II CAT.III CAT.I Description Remars Circits not directly connected to main power spply Circits directly connected to low-oltage facility Home-se eqipment, portable tools, etc. Circits in bilding facilities Switchboards, circit breaers, etc. Spply sorces to low-oltage facilities Oerhead lines, cable systems, etc. Polltion degree Rated measrement inpt oltage EMC-compliant Standards 2 (IEC/EN61010) 600 AC (between terminals) Compliant with EN626 Dring testing, the instrment contines to operate at a measrement accracy within the range of %. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

11 Enironmental Conditions Normal Operating Conditions Warm-p time Ambient temperatre Temperatre change Ambient hmidity Magnetic field Continos ibration Short-time ibration Shoc Monting position Installation altitde Effects on Operating Conditions Effects of ambient Analog otpt: 0.05% of F.S./ C or less temperatre Effects on spply Analog otpt: 0.05% of F.S./ C or less oltage ariations Transport and Storage Conditions Temperatre Hmidity Shoc and dropping of pacage At least 30 mintes 0 to 50 C (reference temperatre: 23 2 C) 10 C/h or less to 90% RH (no condensation) 400 A/m or less 10 to 60 Hz, mm, 75 mintes 60 to 0 Hz, 4.9 m/s 2, 75 mintes 14.7 m/s 2 for seconds or less 98 m/s 2 or less (for shoc time of ms) ertical srface monting only 00 m or less to 70 C 5 to 95% RH (no condensation) 90 cm (proided that an external pacing box is sed) Power Items and Eqations Phase and Wire Syatem Single-phase two-wire system Single-phase three-wire system Three-phase three-wire system Three-phase for-wire system Three-phase for-wire system (2.5 element) Apparent Power A= A Ai= iai i=1, 2 A= A1+A2 Ai= iai i= 1, 3 A= 3 /2(A1+A3) Ai= iai i=1, 2, 3 A= A1+A2+A3 Ai= iai i= 1, 3 A= 3 /2(A1+A3) ( and A are rms ales) Reactie Power (withot sing reactie Power Factor power meter method) Q= ((A) 2 P 2 ) Q= ((Ai) 2 Pi 2 ) i= 1, 2 Q = Q1+Q2 Q= ((Ai) 2 Pi 2 ) i= 1, 3 Q = Q1+Q3 Q= ((Ai) 2 Pi 2 ) i= 1, 2, 3 Q = Q1+Q2+Q3 Q= ( 3 /2(Ai) 2 Pi 2 ) i= 1, 3 Q = Q1+Q3 P/A (withot sing reactie power meter method) * For distorted wae inpt, there may be differences between the PR300 and a measring instrment that ses a different measrement principle. Initial Settings (Time of Shipment) The PR300 has the following initial settings at the time of shipment. Settings can be modified after deliery. Inpt Plse Otpt * 2 Commnication Analog Otpt * 3 Demand Measrement * 4 Setting Item Phase and wire system oltage range T ratio/ ratio Integrated low-ct power Station nmber Protocol Bad rate Parity Stop bit Data length IP address * 1 Port nmber * 1 Sbnet mas * 1 Defalt gateway * 1 Measrement item for plse otpt Plse nit ON plse width Measrement item for analog otpt ower limit of scaling pper limit of scaling Demand power/crrent Demand period Demand alarm mas time Demand power alarm point Demand crrent alarm point Alarm release fnction Indicator-ot mode/indicator-ot Other mode wait time Initial ale Three-phase three-wire system (for three-phase three-wire system) Three-phase for-wire system (for three-phase for-wire system) / % 01 PC lin with checsm 9600 bps None 1 bit 8 bits Actie energy (Wh) 1 Wh/plse 50 ms Actie power (W) 50% (0 W) 100% (maximm ale of the inpt measring range W) Actie power 30 mintes 1 minte 100 W 100 A Atomatic release Off/10 mintes *1 When the Ethernet commnication fnction is specified *2 When plse otpt is specified *3 When analog otpt is specified *4 When demand measrement is specified Monting and Shape Materials Monting Method Connection Method External Dimensions (inclding a terminal coer) Weight Accessories Casing: polycarbonate resin (PC), 94-0 Terminal bloc: polybtylene terephthalate (PBT), 94-0 Terminal coer: polyamide resin (PA6), 94-2 Panel monting (refer to Panel Ctot Dimensions) se of M3 screws for terminal connections: analog otpt, plse otpt, demand alarm otpt, digital inpt, and RS-485 commnication se of M4 screws for terminal connections: oltage/crrent inpt and power spply RJ45 connection: Ethernet commnication 0(H) 0(W) 8(D) mm or 96(H) 96(W) 6(D) mm Approx. 600 g (when the accessories sch as monting bracet are attached) JIS/ANSI-monting it DIN-monting bracet Dst coer (with a screw) Terminal coer (with screws) Shorting bar (for RS-485 commnication termination) Tag nmber label 1 set Related Prodcts (Optionally Aailable) Prodct Name Model Description W0 800A/5A W A/5A Clamp-on crrent transformer W35 300A/1A W 0A/1A W 100A/1A W10 100A/1A A/5A Separate type transformer 0A/1A A/1A All Rights Resered. Copyright 05, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Dec.30, 05-00

12 Connection Diagrams A phase and wire system can be selected by specifying the parameters. If measrement inpt does not exceed 600 AC or 5A AC, direct inpt withot sing a T or is possible. Do not grond the inpt circit when a T or is not sed. Single-phase two-wire system Power-sorce side 1 2 Plse otpt 30 DC, 0mA 14 Analog otpt Otpt signal: 4 to ma DC RS-485 commnication* 1 17 TERM R R: 0 (bilt-in) 18 A B RS-485 SG K l Fse T 1S 1 P1 P ED ED When terminating on wiring, short-circit terminals 17 and N PE Operating range: AC 10% or DC % Optional integration control signal or demand alarm release* 2 D/I D/I oad side CATION Screws mared with are an essential part of the strctre. For safety reasons, do not toch them. Demand alarm otpt AM 30 DC, 0mA 16 AM (resistie load) *1: If Ethernet commnication is sed, the RS-485 commnication interface is sed specifically for the Ethernet-serial gateway fnction. *2: If demand measrement is specified, the demand alarm release is selected. oltage signal ON signal: 4.5 to DC OFF signal: within 1 DC Ethernet commnication RJ45 connector 10BASE-T/100BASE-TX in ED (top) Actie ED (bottom) Color Description Color Description Off Stopped Off Stopped Orange 10Mbps Orange Half dplex Green 100Mbps Green Fll dplex Switching between 10BASE-T and100base-tx taes place atomatically. Switching between half dplex and fll dplex taes place atomatically. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

13 Single-phase three-wire system Power-sorce side 1 N 2 Plse otpt 30 DC, 0mA 14 Analog otpt Otpt signal: 4 to ma DC RS-485 commnication* 1 17 TERM R R: 0 (bilt-in) 18 A B RS-485 SG K l K l Fse T 1S 1 2S 2 P1 P0 P ED ED When terminating on wiring, short-circit terminals 17 and N PE Operating range: AC 10% or DC % Optional integration control signal or demand alarm release* 2 D/I D/I oad side CATION Screws mared with are an essential part of the strctre. For safety reasons, do not toch them. Demand alarm otpt AM 30 DC, 0mA 16 AM (resistie load) *1: If Ethernet commnication is sed, the RS-485 commnication interface is sed specifically for the Ethernet-serial gateway fnction. *2: If demand measrement is specified, the demand alarm release is selected. oltage signal ON signal: 4.5 to DC OFF signal: within 1 DC Ethernet commnication RJ45 connector 10BASE-T/100BASE-TX in ED (top) Actie ED (bottom) Color Description Color Description Off Stopped Off Stopped Orange 10Mbps Orange Half dplex Green 100Mbps Green Fll dplex Switching between 10BASE-T and100base-tx taes place atomatically. Switching between half dplex and fll dplex taes place atomatically. Three-phase three-wire system Power-sorce side A (R) B (S) C (T) Plse otpt 30 DC, 0mA 14 Analog otpt Otpt signal: 4 to ma DC RS-485 commnication* 1 17 TERM R R: 0 (bilt-in) 18 A B RS-485 SG K l K oad side l Fse T 1S 1 3S 3 P1 P2 P CATION Screws mared with are an essential part of the strctre. For safety reasons, do not toch them ED ED Demand alarm otpt AM 30 DC, 0mA 16 AM (resistie load) *1: If Ethernet commnication is sed, the RS-485 commnication interface is sed specifically for the Ethernet-serial gateway fnction. *2: If demand measrement is specified, the demand alarm release is selected. When terminating on wiring, short-circit terminals 17 and N PE Operating range: AC 10% or DC % Optional integration control signal or demand alarm release* 2 D/I D/I oltage signal ON signal: 4.5 to DC OFF signal: within 1 DC Ethernet commnication RJ45 connector 10BASE-T/100BASE-TX in ED (top) Actie ED (bottom) Color Description Color Description Off Stopped Off Stopped Orange 10Mbps Orange Half dplex Green 100Mbps Green Fll dplex Switching between 10BASE-T and100base-tx taes place atomatically. Switching between half dplex and fll dplex taes place atomatically. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

14 14 Three-phase for-wire system Power-sorce side N A (R) B (S) C (T) Plse otpt 30 DC, 0mA 14 Analog otpt Otpt signal: 4 to ma DC RS-485 commnication* 1 17 TERM R R: 0 (bilt-in) 18 A B RS-485 SG K l K l K oad side l Fse T 1S 1 2S 2 3S 3 P1 P0 P2 P CATION Screws mared with are an essential part of the strctre. For safety reasons, do not toch them ED ED Demand alarm otpt AM 30 DC, 0mA 16 AM (resistie load) *1: If Ethernet commnication is sed, the RS-485 commnication interface is sed specifically for the Ethernet-serial gateway fnction. *2: If demand measrement is specified, the demand alarm release is selected. When terminating on wiring, short-circit terminals 17 and N PE Operating range: AC 10% or DC % Optional integration control signal or demand alarm release* 2 D/I D/I oltage signal ON signal: 4.5 to DC OFF signal: within 1 DC Ethernet commnication RJ45 connector 10BASE-T/100BASE-TX in ED (top) Actie ED (bottom) Color Description Color Description Off Stopped Off Stopped Orange 10Mbps Orange Half dplex Green 100Mbps Green Fll dplex Switching between 10BASE-T and100base-tx taes place atomatically. Switching between half dplex and fll dplex taes place atomatically. Three-phase for-wire system (2.5 element) Power-sorce side N A (R) B (S) C (T) Plse otpt 30 DC, 0mA 14 Analog otpt Otpt signal: 4 to ma DC RS-485 commnication* 1 17 TERM R R: 0 (bilt-in) 18 A B RS-485 SG K l K l K l Fse T 1S 1 2S 2 3S 3 P1 P0 P ED ED When terminating on wiring, short-circit terminals 17 and N PE Operating range: AC 10% or DC % Optional integration control signal or demand alarm release* 2 D/I D/I oad side CATION Screws mared with are an essential part of the strctre. For safety reasons, do not toch them. Demand alarm otpt AM 30 DC, 0mA 16 AM (resistie load) *1: If Ethernet commnication is sed, the RS-485 commnication interface is sed specifically for the Ethernet-serial gateway fnction. *2: If demand measrement is specified, the demand alarm release is selected. oltage signal ON signal: 4.5 to DC OFF signal: within 1 DC Ethernet commnication RJ45 connector 10BASE-T/100BASE-TX in ED (top) Actie ED (bottom) Color Description Color Description Off Stopped Off Stopped Orange 10Mbps Orange Half dplex Green 100Mbps Green Fll dplex Switching between 10BASE-T and100base-tx taes place atomatically. Switching between half dplex and fll dplex taes place atomatically. All Rights Resered. Copyright 06, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Feb., 06-00

15 External Dimensions ANSI 4-inch rond form size (when a bezel is attached) 0 2 (6.5) (109) Dst coer nit: mm Terminal coer Bezel (for ANSI-monting) <Panel Ctot Dimensions> 23 2-M5 1 to 10 (Acceptable panel thicness for monting) ANSI 42.9±0.4 (1.688±0.0) 42.9±0.4 (1.688±0.0) 42.9±0.4 (1.688±0.0) ø101.6 (ø4.000) nit: mm (approx. inch) 42.9±0.4 (1.688±0.0) ø7.9 (ø0.3) Mltiple Monting 0 min. (5.8 min.) 7 min. (4.606 min.) Normal Allowable Deiation= ±(ale of JIS B tolerance grade IT18)/2 All Rights Resered. Copyright 05, Yoogawa Electric Corporation GS 77C01E01-01E 1st Edition Dec.30, 05-00

16 16 DIN 96-sqare instrment size 0 96 (4.5) (109) Dst coer nit: mm 96 Terminal coer 109 <Panel Ctot Dimensions> 1 to 10 (Acceptable panel thicness for monting) Monting bracet 2 places (38) nit: mm () Min. 7 Min. 0 Normal Allowable Deiation= ±(ale of JIS B tolerance grade IT18)/2 All Rights Resered. Copyright 05, Yoogawa Electric Corporation Sbject to change withot notice. GS 77C01E01-01E 1st Edition Dec.30, 05-00

Field Communication FXA 675 Rackbus RS-485 Interface monorack II RS-485

Field Communication FXA 675 Rackbus RS-485 Interface monorack II RS-485 Technical Information TI 221F/00/en Field Commnication RS-485 Interface monorack II RS-485 For distribted control of Commtec transmitters and field transmitters with RS-485 interface 19" Racksyst plg-in

More information

DIVAR network 3000 recorder

DIVAR network 3000 recorder Video DIVAR network 3000 recorder DIVAR network 3000 recorder www.boschsecrity.com APP H.265 32 IP channels with incoming 12 MP IP camera spport for view and playback Real time live display for 16 channels

More information

Analog Signal Input. ! Note: B.1 Analog Connections. Programming for Analog Channels

Analog Signal Input. ! Note: B.1 Analog Connections. Programming for Analog Channels B Analog Signal Inpt B.1 Analog Connections Refer to the diagram (page B-10) showing the VAN analog boards for connection of analog inpts. Be sre yo follow the indicated positive and negative polarity

More information

1. Basic safety information 4 2. Proper use 4

1. Basic safety information 4 2. Proper use 4 307041 01 EN Digital twilight switch LUNA 120 top2 1200100/ 1200200 1. Basic safety information 4 2. Proper se 4 Disposal 4 3. Installation and connection 5 Monting the time switch 5 Connecting the cable

More information

¾Strip cable to 8 mm (max. 9) ¾Insert cable in the open DuoFix plug-in terminal at 45. LL2 cables per terminal position possible

¾Strip cable to 8 mm (max. 9) ¾Insert cable in the open DuoFix plug-in terminal at 45. LL2 cables per terminal position possible 307253 45 cable E Time switch TR 610 top3 6100130 TR 612 top3 6120130 DoFix plg-in terminal Test tap Plg-in screwless terminal C contact 1. Basic safety information WARIG Danger of death throgh electric

More information

1. Basic safety information. 2. Proper use. 3. Installation and connection. Time switch installation. Disposal. click. Time switch.

1. Basic safety information. 2. Proper use. 3. Installation and connection. Time switch installation. Disposal. click. Time switch. 307029 Time switch installation EN Time switch SELEKTA 175 top2 1750100 1. Basic safety information!! WARNING Danger of death from electric shock or fire! ¾Installation shold only be carried ot by a qalified

More information

DIVAR network 2000 recorder

DIVAR network 2000 recorder Video DIVAR network 2000 recorder DIVAR network 2000 recorder www.boschsecrity.com APP H.265 16 IP channels with 256 Mbps incoming bandwidth 8 MP (UHD) IP camera spport for view and playback Real time

More information

LTC 8800 Series Allegiant Matrix/Control Systems - Modular

LTC 8800 Series Allegiant Matrix/Control Systems - Modular Video LTC 88 Series Allegiant Matrix/Control Systems - Modlar LTC 88 Series Allegiant Matrix/Control Systems - Modlar www.boschsecrity.com 5 Camera by 4 monitor switching Expandable to larger matrix sizes

More information

LB2 Premium-sound Cabinet Loudspeaker Range

LB2 Premium-sound Cabinet Loudspeaker Range Commnications Systems LB2 Premim-sond Cabinet Lodspeaker Range LB2 Premim-sond Cabinet Lodspeaker Range www.boschsecrity.com High-fidelity msic and speech reprodction Selectable 8 ohm, 70 V and 100 V inpts

More information

DIVAR network 2000 recorder

DIVAR network 2000 recorder Video DIVAR network 2000 recorder DIVAR network 2000 recorder www.boschsecrity.com APP H.265 16 IP channels with 256 Mbps incoming bandwidth 8 MP (UHD) IP camera spport for view and playback Real time

More information

DIVAR network 5000 recorder

DIVAR network 5000 recorder Video DIVAR network 5000 recorder DIVAR network 5000 recorder www.boschsecrity.com APP H.265 32 IP channels with 320 Mbps incoming bandwidth 12 MP IP camera spport for view and playback Real time live

More information

UML Series 42- and 55-inch High Performance HD LED Monitors

UML Series 42- and 55-inch High Performance HD LED Monitors Video UML Series 42- and 55-inch High Performance HD LED Monitors UML Series 42- and 55-inch High Performance HD LED Monitors www.boschsecrity.com Fll HD 1920 x 1080 resoltion Precise color reprodction

More information

1. Basic safety information 4 2. Proper use 4

1. Basic safety information 4 2. Proper use 4 307304 EN Astro Time Switch SELEKTA 170 top3 1700130 SELEKTA 174 top3 1740130 1. Basic safety information 4 2. Proper se 4 Disposal 4 3. Installation and connection 5 Time switch installation 5 Connecting

More information

Sauter Components

Sauter Components 51.362/1 AVM 105S, 115S: Actuator with SAUTER Uniersal Technology (SUT) How energy efficiency is improed Automatic adaptation to ale, precision control and high energy efficiency with minimal operating

More information

DINION 5000 AN. Video DINION 5000 AN. Ultra high resolution 960H sensor

DINION 5000 AN. Video DINION 5000 AN.   Ultra high resolution 960H sensor Video TVL 960H Ultra high resoltion 960H sensor High Dynamic Range to see bright and dark details simltaneosly Detail enhancement Bilinx commnication for remote set-p and control Easy to install The DINION

More information

MIC Series IP Power Supply

MIC Series IP Power Supply Video MIC Series IP Power Spply MIC Series IP Power Spply www.boschsecrity.com MIC power spply with IVA-enabled, integrated Bosch IP technology provides video and control over IP for MIC550, MIC550IR,

More information

DIVAR network 5000 recorder

DIVAR network 5000 recorder Video DIVAR network 5000 recorder DIVAR network 5000 recorder www.boschsecrity.com APP H.265 32 IP channels with 320 Mbps incoming bandwidth 12 MP IP camera spport for view and playback Real time live

More information

LB3-PCx50 Premium Cabinet Loudspeakers

LB3-PCx50 Premium Cabinet Loudspeakers Conications Systems LB3-PCx Premim Cabinet Lodspeakers LB3-PCx Premim Cabinet Lodspeakers www.boschsecrity.com High-qality speech and msic reprodction Weatherized, sited for sheltered otside se Prepared

More information

MIC Series IP Power Supply

MIC Series IP Power Supply Video MIC Series IP Power Spply MIC Series IP Power Spply www.boschsecrity.com MIC power spply with IVA-enabled, integrated Bosch IP technology provides video and control over IP for MIC550, MIC550IR,

More information

DINION 5000 AN. Video DINION 5000 AN. Ultra high resolution 960H sensor

DINION 5000 AN. Video DINION 5000 AN.  Ultra high resolution 960H sensor Video www.boschsecrity.com TVL 960H Ultra high resoltion 960H sensor High Dynamic Range to see bright and dark details simltaneosly Detail enhancement Bilinx commnication for remote set-p and control Easy

More information

VIDEOJET decoder 8000

VIDEOJET decoder 8000 Video www.boschsecrity.com HD, 4K UHD and MP decoding Flexible monitor layots Directly drives p to two 4K UHD monitors Displays VCA metadata Compact size and VESA mont displays video from Standard Definition

More information

DINION AN H. Video DINION AN Ultra high resolution 960H sensor

DINION AN H. Video DINION AN Ultra high resolution 960H sensor Video www.boschsecrity.com 960H Ultra high resoltion 960H sensor High Dynamic Range to see bright and dark details simltaneosly Detail enhancement Bilinx commnication for remote set-p and control Easy

More information

Hybrid Chart Recorder 250 mm (10")

Hybrid Chart Recorder 250 mm (10) Hybrid Chart Recorder 250 mm (10") RD5100 Series U High Speed Scanning at 36 Points/Sec and High-Speed Recording U High Accuracy of 0.05% U Various Industrial Values Can be Measured at the Same Time with

More information

EVENT INPUT/OUTPUT MODULE [PUME]

EVENT INPUT/OUTPUT MODULE [PUME] PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm

More information

VIP X16 XF E Video Encoder

VIP X16 XF E Video Encoder Video VIP X16 XF E Video Encoder VIP X16 XF E Video Encoder www.boschsecrity.com 16 video inpt channels with Dal Streaming Deinterlacing at video inpt and progressive encoding Network-attached iscsi recording

More information

CUSTOM INSTALLATION. Autoleads Custom Installation section provides a full range of quality custom vehicle installation products.

CUSTOM INSTALLATION. Autoleads Custom Installation section provides a full range of quality custom vehicle installation products. Atoleads Cstom Installation section provides a fll range of qality cstom vehicle installation prodcts. From cable terminals, distribtion blocks, phono leads and fses to power management prodcts sch as

More information

FLEXIDOME 5000 AN. Video FLEXIDOME 5000 AN. Ultra high resolution 960H sensor

FLEXIDOME 5000 AN. Video FLEXIDOME 5000 AN.   Ultra high resolution 960H sensor Video www.boschsecrity.com TVL 960H Ultra high resoltion 960H sensor High Dynamic Range to see bright and dark details simltaneosly High impact, vandal-resistant, weatherproof hosing Bilinx commnication

More information

MIC Series 440 Explosion-Protected Camera

MIC Series 440 Explosion-Protected Camera Video MIC Series 440 Explosion-Protected Camera MIC Series 440 Explosion-Protected Camera www.boschsecrity.com Explosion-protected nit certified to ATEX Directive 94/9/EC Exd IIC T6 CSA and Inmetro certified

More information

DIVAR AN H RT APP. Video DIVAR AN H RT high-resolution on HDMI output. Mobile device support (ios, Android)

DIVAR AN H RT APP. Video DIVAR AN H RT high-resolution on HDMI output. Mobile device support (ios, Android) Video www.boschsecrity.com 960H RT APP 960H RT high-resoltion on HDMI otpt Mobile device spport (ios, Android) Remote alarm notification Network fnction for remote viewing, playback and control Simltaneos

More information

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated) INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

NWD 455 FlexiDome IP Cameras

NWD 455 FlexiDome IP Cameras Video NWD 455 FlexiDome IP Cameras NWD 455 FlexiDome IP Cameras www.boschsecrity.com High-impact, vandal-resistant enclosre Advanced color CCD network dome camera NightSense for low light sitations High-performance

More information

MINIMED 640G SYSTEM^ Getting Started. WITH THE MiniMed 640G INSULIN PUMP

MINIMED 640G SYSTEM^ Getting Started. WITH THE MiniMed 640G INSULIN PUMP MINIMED 640G SYSTEM^ Getting Started WITH THE MiniMed 640G INSULIN PUMP let s get started! Table of Contents Section 1: Getting Started... 3 Getting Started with the MiniMed 640G Inslin Pmp...3 1.1 Pmp

More information

DIVAR AN H RT APP. Video DIVAR AN H RT high-resolution on HDMI output. Mobile device support (ios, Android)

DIVAR AN H RT APP. Video DIVAR AN H RT high-resolution on HDMI output. Mobile device support (ios, Android) Video www.boschsecrity.com 960H RT APP 960H RT high-resoltion on HDMI otpt Mobile device spport (ios, Android) Network fnction for remote viewing, playback, control and alarm notification Simltaneos monitoring,

More information

MIC Series 440 Explosion-Protected Camera

MIC Series 440 Explosion-Protected Camera Video MIC Series 440 Explosion-Protected Camera MIC Series 440 Explosion-Protected Camera www.boschsecrity.com Explosion-protected nit certified to ATEX Directive 94/9/EC Exd IIC T6 CSA and Inmetro certified

More information

MIC Series 440 Explosion-Protected Camera

MIC Series 440 Explosion-Protected Camera Video MIC Series 440 Explosion-Protected Camera MIC Series 440 Explosion-Protected Camera www.boschsecrity.com Explosion-protected nit certified to ATEX Directive 94/9/EC Exd IIC T6 CSA and Inmetro certified

More information

ME110SSR ME110SSR-4AP ME110SSR-4APH ME110SSR-4A2P ME110SSR-C ME110SSR-CH ME110SSR-MB. MITSUBISHI Electronic Multi-Measuring Instrument

ME110SSR ME110SSR-4AP ME110SSR-4APH ME110SSR-4A2P ME110SSR-C ME110SSR-CH ME110SSR-MB. MITSUBISHI Electronic Multi-Measuring Instrument MITSBISHI Eectronic MtiMeasring Instrment This mana is a simpe ersion. Pease contact or Serice Networ for a detaied ersion of ser s Mana. ME110SSR ME110SSRAP ME110SSRAPH ME110SSRAP Safety precation ME110SSRC

More information

DCP100 Digital Control Programmer Specifications

DCP100 Digital Control Programmer Specifications DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,

More information

DQMx Series. Digital QAM Multiplexer INSTRUCTION MANUAL. Model Stock No. Description

DQMx Series. Digital QAM Multiplexer INSTRUCTION MANUAL. Model Stock No. Description One Jake Brown Road Old Bridge, NJ 08857-1000 USA (800) 523-6049 (732) 679-4000 FAX: (732) 679-4353 www.blondertonge.com INSTRUCTION MANUAL DQMx Series Digital QAM Mltiplexer Model Stock No. Description

More information

E-Vision Laser 4K Series High Brightness Digital Video Projector

E-Vision Laser 4K Series High Brightness Digital Video Projector E-Vision Laser 4K Series High Brightness Digital Video Projector 4INSTALLATION AND QUICK-START GUIDE 4CONNECTION GUIDE 4OPERATING GUIDE 4REFERENCE GUIDE 118-157A Abot This Docment Follow the instrctions

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page

More information

MetroLED. Linear LED Lighting System for Display Illumination

MetroLED. Linear LED Lighting System for Display Illumination MetroLED Linear LED Lighting System for Display Illmination The MetroLED lighting system. Click, twist, play. LED lighting systems have traditionally been the poor relation to fibre optics when it comes

More information

EX65 Explosion Protected Camera

EX65 Explosion Protected Camera Video EX65 Explosion Protected EX65 Explosion Protected www.boschsecrity.com Electropolished 316L stainless steel or alminm constrction High-resoltion, high-sensitivity Dinion 2X imager with WDR Integrated

More information

LBC 347x/00 Horn and Driver Loudspeaker Range

LBC 347x/00 Horn and Driver Loudspeaker Range Conications Systems LBC 347x/ Horn and Driver Lodspeaker Range LBC 347x/ Horn and Driver Lodspeaker Range High efficiency drivers Excellent speech reprodction Easy assembly Water- and dst protected to

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

MBUS 10 RS232 TO MBUS LEVEL CONVERTER Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit

More information

Chapter 4 (Part I) The Processor. Baback Izadi Division of Engineering Programs

Chapter 4 (Part I) The Processor. Baback Izadi Division of Engineering Programs EGC442 Introdction to Compter Architectre Chapter 4 (Part I) The Processor Baback Izadi Division of Engineering Programs bai@engr.newpaltz.ed Introdction CPU performance factors Instrction cont Determined

More information

HVWIP-Series (HVWIP-T + HVWIP-R)

HVWIP-Series (HVWIP-T + HVWIP-R) HVWIP-Series ( + ) The AG Neovo HVWIP-Series ( + ) LAN video wall matrix extender for digital signage applications. Features > Support 1080P@60Hz up to 100meters in Point-to-Point mode. > Support seamless

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type s with Built-in Linear Motor Type R88D-KN@-ECT-L Contents Ordering Information Specifications General Specifications Characteristics Servo Drives with 100 VAC Input Power Servo Drives with 200 VAC Input

More information

1. Basic safety information. 2. Proper use. 3. Installation and connection. Connecting the cable. Disposal. Time switch installation

1. Basic safety information. 2. Proper use. 3. Installation and connection. Connecting the cable. Disposal. Time switch installation E Astro Time Switch SELEKTA 170 top3 1700130 SELEKTA 174 top3 1740130 307304 45 cable DoFix screwless terminal Test tap Plg-in screwless terminal C contact 1. Basic safety information WARIG Danger of death

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

AMX Precis HDBaseT Receiver and Scaler For use with the Precis 8x8 4K60 HDMI matrix switcher PR01-RX (FG )

AMX Precis HDBaseT Receiver and Scaler For use with the Precis 8x8 4K60 HDMI matrix switcher PR01-RX (FG ) DATA SHEET AMX Precis HDBaseT Receiver and Scaler For use with the Precis 8x8 4K60 HDMI matrix switcher PR01-RX (FG1020-050) Front Rear Overview The AMX Precis PR01-RX HDBaseT Receiver and Scaler provides

More information

51.377/1. AVM 234S: Valve drive with SUT positioner. Sauter Components

51.377/1. AVM 234S: Valve drive with SUT positioner. Sauter Components 51.377/1 AVM 234S: Vale drie with SUT positioner For controllers with a continuous (0...10 V and/or 4...20 ma) or switched output (2- or 3-point control). To operate the through ales or three-way ales

More information

Device/PLC Connection Manuals

Device/PLC Connection Manuals Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection

More information

DESCRIPTION FEATURES APPLICATIONS. LTC7543/LTC8143 Improved Industry Standard Serial 12-Bit Multiplying DACs TYPICAL APPLICATION

DESCRIPTION FEATURES APPLICATIONS. LTC7543/LTC8143 Improved Industry Standard Serial 12-Bit Multiplying DACs TYPICAL APPLICATION Improved Industry Standard Serial -Bit Multiplying DACs FEATRES Improved Direct Replacement for AD754 and DAC-84 Low Cost DNL and INL Over Temperature: ±0.5LSB Easy, Fast and Flexible Serial Interface

More information

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide Operating Instructions Coaxial - LAN Converter with PoE function Model No. Indoor Use Only BY-HPE11KTA Attached Installation Guide Before attempting to connect or operate this product, please read these

More information

Video Server SED-2100R/S. Quick Installation Guide

Video Server SED-2100R/S. Quick Installation Guide Video Server SED-2100R/S Quick Installation Guide Feb.10,2006 1 1 Getting Started 1.1 PACKAGE CONTENTS SED-2100 Warranty Card Software CD Hook up & Screws Terminal Blocks for Power & DI/O Power Adaptor

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

100 Hz Chassis 28 CTV

100 Hz Chassis 28 CTV SERVICE MANUAL 100 Hz Chassis 28 CTV Contents Technical Data..............................................4 Recommendation for service repairs............................5 Component description.......................................7

More information

Product Overview 2009

Product Overview 2009 Prodct Overview 2009 Living high tech 1 Contents Editorial...3 The new ECoS 4 The new ECoS - Jst Play...5 Fnctions detailed...7 Expandibility...9 ECoS 10 ECoS...10 Expandibility...11 Navigator 12 Eqipment

More information

System Interface Unit SIU-100/100T

System Interface Unit SIU-100/100T System Interface Unit /100T Since its introduction, the Digital Mixer has opened up an entirely new set of opportunities for affordable PA and sound-recording applications. Recognizing the ever-increasing

More information

General Specifications

General Specifications General Specifications GS 12E01A06-01E Model TB750G Right Angle Scattered Light Turbidimeter General There are increasing demands for good quality water for both industrial-use and drinking water applications

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04 10MSPS, 12-bit Analog Board for PCI AI-1204Z-PCI * Specifications, color and design of the products are subject to change without notice. This product is a PCI bus-compliant interface board that expands

More information

AF-300 E11 Adjustable Frequency Drive

AF-300 E11 Adjustable Frequency Drive AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed

More information

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX Description This Ethernet Switch Module has been designed with 4x10/100Base-TX ports and 1x100Base-FX fiber optic port for the interconnection

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data Product description Dimmable built-in for LED Constant current (with 2 adjustable output channels) Designed for outdoor and street luminaire Output power 2 x 38 W Suitable for mains voltage peaks (burst/surge)

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

E-Vision Laser 7500 Series E-Vision Laser 8500 Series E-Vision Laser 10K Series High Brightness Digital Video Projector

E-Vision Laser 7500 Series E-Vision Laser 8500 Series E-Vision Laser 10K Series High Brightness Digital Video Projector E-Vision Laser 7500 Series E-Vision Laser 8500 Series E-Vision Laser 10K Series High Brightness Digital Video Projector 4INSTALLATION AND QUICK-START GUIDE 4CONNECTION GUIDE 4OPERATING GUIDE 4REFERENCE

More information

HIGHlite 4K Series High Brightness Digital Video Projector

HIGHlite 4K Series High Brightness Digital Video Projector HIGHlite 4K Series High Brightness Digital Video Projector 4INSTALLATION AND QUICK-START GUIDE 4CONNECTION GUIDE 4OPERATING GUIDE 4REFERENCE GUIDE Rev A Febrary 2018 118-083A Abot This Docment Follow the

More information

A Buyers Guide to Laser Projection

A Buyers Guide to Laser Projection The Eropean Digital Cinema Form A Byers Gide to Laser Projection AUTUMN 2018 Table of Contents Slides 2-5 Introdctory notes Slides 6-22 1: Technical Considerations Slides 23-31 2. Financial and lifetime

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

ADJUSTABLE SPEED DRIVES. nc1 Drive

ADJUSTABLE SPEED DRIVES. nc1 Drive ADJUSTABLE SPEED DRIVES nc1 Drive Ultra-Compact Sub-Micro Drive The nc1 is a sub-micro, or nano-sized drive with a full range of features to meet the needs of nearly any user. The nc1 is designed to be

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES APPLICATION LPD04SA-15B-R (29.9 59.9 172mm) This product is digital display for system which is most suitable for display of various data of main

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information. CSM DS_E_1_1 Continuously monitor dust fallout and particles which detract from product quality. Compact design ideal for continuous monitoring Equipped with various interfaces such as a LAN port. Accurately

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

HDMI / Video Wall over IP Receiver with PoE

HDMI / Video Wall over IP Receiver with PoE / Wall over IP Receiver with Key Features Network 1080P ultra high quality video transmitter Assigns video sources to any monitor of the video wall Up to 8 x 8 Screen Array supported Extends high definition

More information

Industrial Wi-Fi Access Point and Client - DM500

Industrial Wi-Fi Access Point and Client - DM500 Industrial Access Point and Client - High Performance Entry-Level Access Point The is an IEEE 802.11n Access Point, that provides even for very demanding applications sufficient performance at a maximum

More information

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier Kramer Electronics, Ltd. USER MANUAL Model: 900xl Power Amplifier Introduction Contents 1 Introduction 1 2 Getting Started 1 2.1 Recycling Kramer Products 1 3 Overview 2 4 Your 900xl Power Amplifier 3

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

SINEAX A 210 / A 220 Multifunctional Power Monitor

SINEAX A 210 / A 220 Multifunctional Power Monitor SIEA A 10 / A 0 Mtifnctiona ower Monitor 63 measred qantities 8 energy meters 5 aerage power aes, Q, S each Appication The A 10/A 0 power measring instrment is sitabe for contro pane monting and measres

More information

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display. ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read

More information

NPN type (Analogue/Voltage/Dual) Laser type. PNP type (Analogue/Voltage/Dual) NPN type (RS422) PNP type (RS422) Pins configuration

NPN type (Analogue/Voltage/Dual) Laser type. PNP type (Analogue/Voltage/Dual) NPN type (RS422) PNP type (RS422) Pins configuration Displacement Sensor CD33 SERIES Laser type Connection diagram NPN type (Analogue/Voltage/Dual) CD33-30 CD33-50 CD33-120 CD33-250 INSTRUCTION MANUAL Confirm if the item meets your needs. Before the use,

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

Type SCH94FO. Type SCH94FO. Description

Type SCH94FO. Type SCH94FO. Description Type SCH94FO Hollow Shaft Fiber Optic Encoder - Ø 94 mm Dual Output Option (Digital & Fiber Optic) Fiber Optic Transmission up to 2,000 meters (~ 1.25 miles) No Degradation of Encoder Signal from Electrical

More information

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES pag. 1/13 FEATURES Outputs: 4 x channels BUS+SEQUENCER+FADER+DIMMER+DRIVER Input: DC 12/24/48 Vdc BUS Command: DALI LOCAL Command: 4x N.O. push button (with or without memory), 0-10V, 1-10V Controls: dimmer,

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

1x12 VGA & Audio over CAT5 Splitter

1x12 VGA & Audio over CAT5 Splitter SP-9112 1x12 VGA & Audio over CAT5 Splitter User Manual rev: 160322 Made in Taiwan Safety and Notice The SP-9112 1x12 VGA & Audio over CAT5 Splitter has been tested for conformance to safety regulations

More information

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE

More information

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm) SC-N/SA Series 7 Segment Display Unit 7 SegmneDisplay Unit With High Bright Characters (SC-N : W32 H57mm, SA Series: W H22mm) Features Selectable decimal (0 to 9) or hexadecimal (0 to 9, A to F) indication

More information

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet Cable Extension Position Sensors with internal magnetic encoder Position Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information