Finding a key detection method with TRIZ

Size: px
Start display at page:

Download "Finding a key detection method with TRIZ"

Transcription

1 Finding a key detection method with TRIZ Author: Dr.-Ing. Robert Adunka Abstract The old design of the 3SB1 lock used a micro switch to detect if the key is within the lock. To use this micro switch, cables had to be run through the lock and to be connected to a special socket. A special device had to be used to connect to this socket and to transfer the signal to the wires. The task was to make the whole design smaller and reduce the costs of the assembly. After several other solutions were tried and none led to the desired end, a TRIZ workshop was conducted. Within that workshop, a function analysis (modern TRIZ, as in TechOptimizer) with a trimming variant was created. Resources were listed and 40 inventive principles were used. The solution that was found reduced the manufacturing costs dramatically, was much smaller than the original design and had also a new feature that was appreciated a lot by the customer. Initial Situation A new generation of a key lock with key detection should be developed. There was already a new generation - the so called 3SB3 locks - in place. The key lock with key detection was in the old fashion series of locks, which is named 3SB1. So this special 3SB1 lock was the object of the improvement. In this lock a micro switch was used to detect the insertion of a key into the lock. The micro switch was inserted in the cylinder of the lock. It detected the key insertion within the first 4mm of the insertion. This is a requirement for the lock, as it is not allowed to detect the key at the very end of its 20mm long insertion. The micro switch gives his signal over two wires to a special socket (see fig. 1). Figure 1: Cross section through the lock with key detection Lock Cylinder Key Pins Lock Housing Contact Element Socket Ball Micro Switch Internal Wires Actuator Assembly

2 This socket is comparable to a socket which is used for light bulbs. It has two contact areas that are then contacted by a special contacting assembly that is snapped onto the bottom of the lock. This contacting assembly has two contacting elements that touch the contact areas of the socket and that are connected to screws. These screws are used to attach a wire to the contacting elements. Because of the size of the micro switch, the whole body of the lock is bigger than it should be for the 3SB3 design series. There are also problems associated with the assembly of the lock. In order to avoid malfunction, care had to be taken, that the wires that run from the mcro switch to the socket, were not squeezed too hard. To improve the situation, a new generation of locks should be developed. To do this, the main customer for those locks was asked early in the conceptual design phase. In different scheduled meetings, solutions by Siemens and the manufacturer of the key lock were presented to him. Figure 2: Concept Slider One of the solutions presented by Siemens is shown in figure 2. The key 3 moves a slider 5 that lies within the lock cylinder 4. The slider 5 then presses on a pusher 6 that is under spring loaded by spring 7. The pusher 6 then presses on a standard switching element 2. The switching element 2 has a movable bridge within that connects or disconnects two fixed. Via screws wires can be connected to the fixed. With this solution the requirement for the early detection of the key within the lock could be recognized. The first few millimeters the key is inserted into the lock, the slider moves. The contact is made after the first four millimeters. The rest of the key insertion, the slider is out of the way to allow the key to be inserted to the very end of the lock cylinder. Also another concept is shown in this example: the use of the standard switching element. This switching element is used as a normally closed (NC) or normally open (NO) switching element which is attached to the bottom of push buttons and key locks for the detection of the push button being pressed or the key which is turned. As it is used in other assemblies of the 3SB3 series, it would be a good solution to have this standard switching element also used to do the job of the micro switch.

3 The concept of the solution was very good from the perspective of the functionality. The only drawback was that the key lock manufacturer announced that he is not able to manufacture a lock with a slider inside. Therefore the manufacturer came up with another solution, which is shown in figure 3. Figure 3: Concept 23mm pusher In the manufacturer s solution, the pusher was located in the center of the cylinder and an additional slider was inserted with a little offset. That way the lock would be easy to manufacture. The problem with this solution was, that the slider and the pusher would move the whole 23mm that the key is inserted. So as the key is inserted 23mm, the pusher will come out 23mm from the bottom of the lock. The standard switching element will just need 4mm displacement to connect or disconnect. With that solution of the lock manufacturer, the standard switching element couldn t be used. Along with other solutions those concepts were presented to the main customer one at a time. None of them were accepted by the customer. Therefore a two day workshop was set up to deal with the problem. Proceeding in the workshop The first thing to do in the workshop was to brain write all ideas down, that the participants already had. This is a very important step in every idea workshop. If the participants don t get the possibility to write down what is already in their heads, they could not be open for new concepts and ideas. After this initial step, a function analysis was performed on the system. The model is shown in figure 4 and has some minor drawbacks in terms of accuracy, which is based on the knowledge level of the team members of the workshop. But for the cause of the workshop, the model was of sufficient accuracy. As the model just showed how the different parts of the lock worked together and as there were no problems stated, a trimming was done on the model. With the trimming step different new scenarios were built to create artificially problems. To do a trimming one or more components of the model have to be trimmed and their useful functions transferred to new components. As those functions are transferred to new components which didn t do those functions before, new tasks arise. Those are tasks that question the engineers how the function can be performed by the other component. Finding answers to those tasks results in new concepts for a new key lock. One of those scenarios is shown in figure 5. This scenario also brings in an X-component that wasn t in the original design and now should do magically the job of all the other trimmed components. For better readability two functions were rearranged in figure 5 (numbered function 1 and 2).

4 User Figure 4: Function analysis of the 3SB1 lock removes inserts Key displaces Ball actuates Micro Switch Internal Wires turns Pins adjusts locks takes in Lock Cylinder locates Lock Housing Actuator Assembly emits Contact Element Socket Signal Figure 5: Trimming scenario User turns Pins removes adjusts inserts locks displaces 1 Key takes in displaces 1 locates X-Component Lock Cylinder Ball emits 2 Signal Assembly Micro Switch actuates Lock Housing Micro Switch Internal Wires Actuator Assembly Contact Element Socket emits 2 Signal

5 In the scenario described in figure 5 all components of the micro switch and those associated with the micro switch are trimmed. Those are all the elements that make a detection of the key possible first hand. The key now does something (not necessarily displaces) to the X-Component, which responds on this action with the emission of the wanted signal. That means that the action 1 (displaces) now points to the X-component instead of the ball. The action 2 (emits) that was formerly done by the socket will now be done by the X-component. A task derived from this scenario is: How can the X- component emit a signal when it is displaced? The solution of this problem would remove the need for a micro switch. Besides going for the trimming scenario the group also dealt with the different detection methods that could be used on the key. To tackle the problem of detection, different features of the key were listed, that could be detected: Conducts electricity Reflects light Cuts light beam Changes impedance of a coil Codes with profile Could be magnetic Cohesion Temperature Mass Stability Stiff, static part Robustness With a feature transfer the existing concept was compared to the concept slider (figure 2) and another inferior concept (concept latch ). With the comparison of the three different concepts the team members tried to transfer features of one lesser rated concept to a better rated concept which had a weak shot in the feature under consideration. Although feature transfer normally generates very good solutions, it didn t work to well in the task at hand. Table 1: Feature transfer Simplicity Number of Protection class Micro switch Concept Slider Concept Latch Ease of assembly Manufacturability Switching capacity Diameter

6 Beside those more analytic tools the 40 innovative principles were also used to generate more ideas. The contradiction matrix and analysis of technical contradictions was used in this context but was turned down by the participants. The physical contradiction analysis was not used in that context. A presentation with 40 slides, each depicting one principle and examples for it, was given as a handout. Conclusion There were only four participants in the workshop, but those four generated 39 additional solutions to the given task. Those solutions were then discussed with the lock manufacturer. The solution that was favored by the lock manufacturer was then presented to the customer as a mock up only two weeks after the ideas were discussed with the lock manufacturer. The concept of the solution as it was drawn in the workshop is shown in figure 6. The concept is based on the principle of the 23mm pusher (see figure 3). The pusher is substituted by a telescopic bar clearly a principle 7 (Nesting, Matrioshka ) at work. The telescopic bar is spring loaded. The spring that lies within the telescopic bar pushes the ends away from each other. In the detailed solution, a second spring on the outside of the telescopic bar was added to hold it in place. Also the inner and the outer spring had to be coordinated in that fashion that they correspond to the spring in the standard switching element in the bottom of the key lock. Figure 6: Concept Telescopic Bar A summary of some of the advantages of the new solution in comparison to the old solution is shown in figure 7. What made it also very attractive to the customer is the fact that we were able to add a new feature into the design. The key is now automatically ejected in the 0 -position of the lock. This is good, because with that feature the user now cannot forget his key in this safety relevant key lock.

7 3SB1 Figure 7: Summary of the parameters 3SB3 Former design 30 V / 0,5 A NC special switching element Vulnerable to dirt Extra size No accessory useable Key is in lock when at 0 position Parameter Switch. capacity Tapping Form and size Key ejection 400 V / 10 A New design NC/NO standard switching element Protected in switch cabinet Standard size Standard accessory usable Key is ejected in 0 position Biography Dr. Robert Adunka was born in 1971 in Sulzbach-Rosenberg, Germany. After his study of production engineering at the Friedrich-Alexander-University Erlangen he worked as a scientific assistant and lecturer at the Institute for engineering design, University Erlangen-Nurnberg. In this timeframe he also had a sideline job as Application Engineer for Invention Machine Germany GmbH (Innovation coach and facilitator of workshops in over 30 companies in Germany, Austria, Switzerland and Liechtenstein). In 2002 he fortified his Ph.D. thesis "Computer-aided Evaluation Process in the Field of Methodic Product Development". After his Ph.D. he went to the Siemens AG, Automation and Drives. After working as an engineer for electro-mechanical switching devices, he took on a job as an internal consultant on innovation methods within the same division. In this position facilitated over 30 Workshops and is now heading the Innovation Tool Academy an internal training program, mainly based on TRIZ. Since 10/2001 he is recognized as "Innovation Master" and since 03/2006 he a MATRIZ Level 3 Certificate. His name is mentioned on 25 invention disclosures, which led up to now to 17 granted patents.

Building a MidiBox LCD Cable

Building a MidiBox LCD Cable Building a MidiBox LCD Cable By Jim Henry, 3-Apr-2004 An LCD panel may be connected to the Core module by a 16 conductor flat ribbon cable. A 16 pin insulation displacement connector (IDC) terminates one

More information

RGB 5050 PixelControl LED Super Flat Rope Part Numbers: PSFR-RGB-W-20

RGB 5050 PixelControl LED Super Flat Rope Part Numbers: PSFR-RGB-W-20 11235 West Bernardo Court, Suite 102 San Diego, CA 92127 888-880-1880 Fax: 707-281-0567 EnvironmentalLights.com RGB 5050 PixelControl LED Super Flat Rope Part Numbers: PSFR-RGB-W-20 PixelControl LED Super

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Complete Fine Beam Tube System 1013843 Instruction sheet 10/15 SD/ALF If it is to be expected that safe operation is impossible (e.g., in case of visible damage), the apparatus is

More information

Sensor technologies Proximity sensors Series ST4. Brochure

Sensor technologies Proximity sensors Series ST4. Brochure Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with

More information

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max.

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max. PKK loa d / (kg/m) PKK 10 8 6 4 2 0 0 P KK 1 20 PKK applications 49 PKK dimensions 50 PKK types 52 PKK sizes 54 PKK parts 55 PKK assembly 56 PKK article numbers 62 LOAD DIAGRAM PKK 2 2 0 2 P KK 2 40 PKK

More information

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie. Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin,

More information

Flexible. Fast. Precise. PPU-E Pick & Place Unit

Flexible. Fast. Precise. PPU-E Pick & Place Unit PPU-E Flexible. Fast. Precise. PPU-E Pick & Place Unit Compact 2-axis unit for a faster, flexible running of any curve on one plane. Field of Application For use in clean and slightly polluted environment.

More information

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max.

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max. loa d / (kg/m) PKK inner height / (mm) 10 8 6 4 2 0 0 118 115 80 50 30 16 7 48 7 P KK 1 20 30 PKK applications 49 PKK dimensions 50 PKK types 52 PKK sizes 54 PKK parts 55 PKK assembly 56 PKK article numbers

More information

Design Guide DSK/DSL

Design Guide DSK/DSL Page 1 of 16 Original version of the design guide For Components DSK 14.26 DSL 14.26 DSK 30.42 DSL 30.42 DSK 50.75 DSL 50.75 DSK 140.170 DSL 140.170 DSK 14.26 DSL 15.28 DSK 30.47 DSL 30.47 DSK 50.80 DSL

More information

Fiber Optic Meter Fiber Optic Source

Fiber Optic Meter Fiber Optic Source FOM/FOS Fiber Optic Meter Fiber Optic Source Warning To avoid injury: do not service the FOM or FOS unless you are qualified to do so. The service information provided in this document is for the use of

More information

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No. Sensor module Ref.No.: SM 1608 V03 Safety instructions Caution! Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the installation information could

More information

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

19 TiRAX cabinet system. from page 3. 19 NETcell cabinet system from page 31. Open 19 racks from page 43 19" TiRAX cabinet system from page 3 19" NETcell cabinet system from page 31 Open 19" racks from page 43 all-mounting/stand-alone distribution systems from page 53 all-mounting enclosure systems from page

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

Swiveling unit. Smooth and precise swiveling

Swiveling unit. Smooth and precise swiveling NEW Swiveling unit RSP-FLEX Smooth and precise swiveling Swiveling unit RSP-FLEX Especially with automated loading and unloading of machine tools, the RSP-Flex swivel units offer an alternative to expensive

More information

NEW SWIVELING UNIT RSP-FLEX. Smooth and precise swiveling

NEW SWIVELING UNIT RSP-FLEX. Smooth and precise swiveling NEW SWIVELING UNIT RSP-FLEX Smooth and precise swiveling SWIVELING UNIT RSP-FLEX Especially with automated loading and unloading of machine tools, the RSP-Flex swivel units offer an alternative to expensive

More information

SubstiTUBE Value ST8-HV5

SubstiTUBE Value ST8-HV5 www.osram.com SubstiTUBE Value ST8-HV5 Datasheet Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 66% by replacing 1.5 m T8 fluorescent

More information

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion ES-Mega MegaBeans Access Control System User Manual / Order No. Device People in Motion Contents 1. General description..3 2. Installation Instructions..4 3. Start-up..4 4. Audible signals..4 5. Operating

More information

DL-AR2 Technical Specifications Universal HDMI Adapter Ring Rev

DL-AR2 Technical Specifications Universal HDMI Adapter Ring Rev DL-AR2 Technical Specifications Universal HDMI Adapter Ring Rev. 130814 The DL-AR2 Digital Adapter Keychain was developed to support the rising proliferation of mobile devices used in presentation systems.

More information

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1 Content 1. Company Profile... 3 2. Product Introduction... 3 3. Operation Instruction...

More information

Panel-mounting thermostats, type series EM

Panel-mounting thermostats, type series EM Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting

More information

Contents Introduction Safety Cleaning Connections Cartridge gain and loading Technical specification Fig.1 PS.30R/ PS.30RDT rear panel Fig.

Contents Introduction Safety Cleaning Connections Cartridge gain and loading Technical specification Fig.1 PS.30R/ PS.30RDT rear panel Fig. Contents Introduction Safety Cleaning Connections Cartridge gain and loading Technical specification Fig.1 PS.30R/ PS.30RDT rear panel Fig.2 Basic audio connection Fig.3 Removing the lid Fig 4 Gain and

More information

SU17 Series Fiber Optic Sensors

SU17 Series Fiber Optic Sensors SU17 Series Fiber Optic Sensors Fiber Optic Diffuse and Thru-Beam Mode See page 750 Sensing Range: Determined by fiber optic cable Output: NPN, PNP Built-in auto-tuning Digital display Mutual interference

More information

Topic: Instructional David G. Thomas December 23, 2015

Topic: Instructional David G. Thomas December 23, 2015 Procedure to Setup a 3ɸ Linear Motor This is a guide to configure a 3ɸ linear motor using either analog or digital encoder feedback with an Elmo Gold Line drive. Topic: Instructional David G. Thomas December

More information

SubstiTUBE Value ST8V-0.6m

SubstiTUBE Value ST8V-0.6m www.osram.com SubstiTUBE Value ST8V-0.6m Datasheet Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 64% by replacing 0.6 m T8 fluorescent

More information

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro WID-DL74 WID-DL74 BLP WID Designed for BrightLink Pro Installation guide for workitdesk interactive table BrightLink Pro for Mounting the table unit 1 Unpack boxes 1 of 4 (Mobile base) and 2 of 4 (Motorized

More information

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces Automatic s 2004 Automatic. All rights reserved. pdf 1.0 3-18-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable Plugs...................

More information

COLOUR CHANGING USB LAMP KIT

COLOUR CHANGING USB LAMP KIT TEACHING RESOURCES SCHEMES OF WORK DEVELOPING A SPECIFICATION COMPONENT FACTSHEETS HOW TO SOLDER GUIDE SEE AMAZING LIGHTING EFFECTS WITH THIS COLOUR CHANGING USB LAMP KIT Version 2.1 Index of Sheets TEACHING

More information

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM www.osram.com SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM Datasheet Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 63% by replacing

More information

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1 Product Brochure Version 1. R&S HZ-15/R&S HZ-17 Probe Sets R&S HZ-16 Preamplifier E and H near-field emission measurements with test receivers, spectrum analyzers and oscilloscopes HZ-15_16_17_bro_en_5213-6687-12_v1.indd

More information

SLiC Fiber Aerial Closure System

SLiC Fiber Aerial Closure System 3 SLiC Fiber Aerial Closure System SLFC 533-SP SLFC 533-TS SLFC 733-SP Instructions May 2005 78-8135-4502-3-B N C H E S R A N G E M IL L IM E T E R S.4 10.6.8 A B C 15 20 I 1.0 Kit Contents Note: Examine

More information

Figure 1: Device components

Figure 1: Device components Order No. : 2860 10 Order No. : 2830 10 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe

More information

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions High Density Block BRCP HD BRCP- 128/192/256 pair Installation Instructions Product Introduction The BRCP block is the latest generation of MDF terminal blocks developed by 3M, specifically designed for

More information

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N In-line and butt version Cold applied re-usable fiber optic closure Contents 1 Introduction 1.1 Product description 1.2 Capacity 2 General

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

MAGNETIC TAPE. Series MB. incremental scale. Key-Features: MAGNETIC TAPE incremental scale Series MB Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...3 Installation Instruction...3 Digital Displays...4 Order Code...5 - Available

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

Color Star Advanced Talking Color Identifier Light Detector and Light Analyzer

Color Star Advanced Talking Color Identifier Light Detector and Light Analyzer USER MANUAL Color Star Advanced Talking Color Identifier Light Detector and Light Analyzer EN TABLE OF CONTENTS 1. INTRODUCTION 2 2. DESCRIPTION OF THE DEVICE 3 3. CHARGING THE BATTERY 4 4. HOW TO TURN

More information

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity HD Flex Patch Panel Part Numbers: FLEX1UPN**, FLEX2UPN**, FLEX4UPN** Panduit Corp. 2018 INSTALLATION INSTRUCTIONS Note: HD Flex Patch Panels are compatible with HD Flex Fiber System Components. HD Flex

More information

RAIL D-SUB BACKSHELLS

RAIL D-SUB BACKSHELLS RAIL D-SUB BACKSHELLS FOR D-SUBMINIATURE CONNECTORS D-SUB BACK SHELLS /// DATA SHEET RAIL D-SUB BACKSHELLS FOR D-SUBMINIATURE CONNECTORS TE Connectivity (TE) provide a comprehensive range of ruggedized

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1995 Metric CSJ 0508-01-258 SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1.0 Description This Item shall govern for the furnishing and installation of color Single

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS B SCIENTIFIC PHYSICS Triode S 11 Instruction sheet 1/15 ALF 1 5 7 1 Guide pin Connection pins Cathode plate Heater filament 5 Grid Anode 7 -mm plug for connecting anode 1. Safety instructions Hot cathode

More information

TV Lift System Model CL-65 Installation Instructions

TV Lift System Model CL-65 Installation Instructions TV Lift System Model CL-65 Installation Instructions Contact: Support@Nexus21.com Toll Free: (866) 500-5438 Phone: (480) 951-6885 Fax: (480) 951-6879 Revised: 01/17/17 Below is a parts list describing

More information

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements Product Brochure Version 01.01 R&S ZN-Z32/-Z33 Automatic In-Line Calibration

More information

SubstiTUBE Advanced ST8-HA4

SubstiTUBE Advanced ST8-HA4 www.osram.com SubstiTUBE Advanced ST8-HA4 Datasheet Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 60% by replacing 36 W (1.2 m) T8

More information

MONDO VIDEOSCREENS AND LED SOLUTIONS

MONDO VIDEOSCREENS AND LED SOLUTIONS MONDO VIDEOSCREENS AND LED SOLUTIONS DESCRIPTION A MONDO video screen is not only a product but a full package that includes personalized service done at different stages, from before to after the production

More information

Heating thermostat Series AMHs B Operating Instructions 11.06/

Heating thermostat Series AMHs B Operating Instructions 11.06/ Heating thermostat Series AMHs-1-80 B 60.3045.0 Operating Instructions 11.06/ 00367556 Typographical conventions Warning signs The signs for Danger and Warning are used in this manual under the following

More information

Processing Specification MiniBridge IDC

Processing Specification MiniBridge IDC Processing Specification MiniBridge IDC ERNI Electronics GmbH & Co. KG Seestrasse 9 l 73099 Adelberg / Germany l +49 7166 50-0 l www.erni.com Version 5 IMS Verarbeitungsspezifikationen Seite 1 von 11 Table

More information

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL !!! ATTENTION - NOTICE FOR THE INSTALLER!!! The bridges present on the contacts STOP, SENSITIVE EDGE, PHOTOCELLS, will not be installed anymore

More information

Catalogue Ignitors and power switches for HID

Catalogue Ignitors and power switches for HID Catalogue 2012 Ignitors and power switches for HID Overview Product overview Ignitor matrix Standards Page 6 Page 7 Page 8 Product information Ignitors and power switches for HID Page 9 Superimposed-pulse

More information

SubstiTUBE Value EM ST8V-1.2m-17W-EM

SubstiTUBE Value EM ST8V-1.2m-17W-EM www.osram.com SubstiTUBE Value EM EM Datasheet Technical operating data Product 865-EM 840-EM Color Colortemp. [K] Lum. Flux [lm] Cool Daylight 6500 K 1700 Cool White 4000 K 1700 830-EM Warm White 3000

More information

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2179-CD Series Fiber Optic Splice Closure. Installation Instructions 2179-CD Series Fiber Optic Splice Closure Installation Instructions 1.0 Product Introduction The new 3M TM 2179-CD Series Fiber Optic Splice Closure can be used in buried, underground, aerial, and pedestal

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DLP200M 2 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless

More information

NOTICE. The above identified patent application is available for licensing. Requests for information should be addressed to:

NOTICE. The above identified patent application is available for licensing. Requests for information should be addressed to: Serial Number 09/311.900 Filing Date 14 May 1999 Inventor Gair P. Brown Yancy T. Jeleniewski Robert A. Throm NOTICE The above identified patent application is available for licensing. Requests for information

More information

LED Backlight for Technics amplifiers

LED Backlight for Technics amplifiers LED Backlight for Technics amplifiers Technics SE-A900S Technics SE-A900SM2 Technics SE-A909S Technics SE-A1000 Technics SE-A1000M2 Technics SE-A1010 Rev. 1.2 B Description The LED module is designed to

More information

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX 5 APPENDIX 5. TROUBLE SHOOTING LED MODULE SITUATION CAUSE ACTION Can not receive DMX signal ) DMX signal cable error 2) Signal connection error 3) The input signal IC damaged 4) DMX address error ) Check

More information

12G Broadcast connectors

12G Broadcast connectors 12G Broadcast connectors Delivering 12G in a single punch www.coax-connectors.com Welcome to COAX 12G BNC Plug return loss COAX Connectors Ltd is a leading UK designer, manufacturer and supplier of high

More information

BASIC PH METER BASIC PH METER KIT

BASIC PH METER BASIC PH METER KIT BASIC PH METER 840087 BASIC PH METER KIT 840088 Instruction Manual 2 TABLE OF CONTENTS I. INTRODUCTION... 3 II. PANEL DESCRIPTION... 4 III. OPERATING INSTRUCTIONS A. PH CALIBRATION PROCEDURE... 5 B. MEASUREMENT

More information

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Measurement Accuracy of the ZVK Vector Network Analyzer

Measurement Accuracy of the ZVK Vector Network Analyzer Product: ZVK Measurement Accuracy of the ZVK Vector Network Analyzer Measurement deviations due to systematic errors of a network analysis system can be drastically reduced by an appropriate system error

More information

MKE platinum-c. Bedienungsanleitung Instructions for use Notice d emploi Istruzioni per l uso Instrucciones para el uso Gebruiksaanwijzing

MKE platinum-c. Bedienungsanleitung Instructions for use Notice d emploi Istruzioni per l uso Instrucciones para el uso Gebruiksaanwijzing MKE platinum-c Bedienungsanleitung Instructions for use Notice d emploi Istruzioni per l uso Instrucciones para el uso Gebruiksaanwijzing MKE platinum-c The MKE platinum-c is a high-quality, sub-miniature,

More information

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment

More information

System Quality Indicators

System Quality Indicators Chapter 2 System Quality Indicators The integration of systems on a chip, has led to a revolution in the electronic industry. Large, complex system functions can be integrated in a single IC, paving the

More information

SC26 Magnetic Field Cancelling System

SC26 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields

More information

MKE 2 Gold. Instruction manual

MKE 2 Gold. Instruction manual MKE 2 Gold Instruction manual Parts Metal Parts Pb Hg Cd Cr 6+ PBB PBDE EFUP x o o o o o 15 Circuit Modules Cables & Cable Assemblies Circuit Breakers o x o o o o o x o o o o o x o o o o o 15 15 15 x Important

More information

QUIZ BUZZER KIT TEACHING RESOURCES. Version 2.0 WHO ANSWERED FIRST? FIND OUT WITH THIS

QUIZ BUZZER KIT TEACHING RESOURCES. Version 2.0 WHO ANSWERED FIRST? FIND OUT WITH THIS TEACHING RESOURCES SCHEMES OF WORK DEVELOPING A SPECIFICATION COMPONENT FACTSHEETS HOW TO SOLDER GUIDE WHO ANSWERED FIRST? FIND OUT WITH THIS QUIZ BUZZER KIT Version 2.0 Index of Sheets TEACHING RESOURCES

More information

RESOLUTION MSC.95(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR DAYLIGHT SIGNALLING LAMPS

RESOLUTION MSC.95(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR DAYLIGHT SIGNALLING LAMPS MSC 72/23/Add.1 RESOLUTION MSC.95(72) THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning the functions of Committee, RECALLING

More information

Safety Light Curtain C 4000

Safety Light Curtain C 4000 O P E R A T I N G I N S T R U C T I O N S Safety Light Curtain C 4000 Operating Instructions Chapter 2 On safety 2 On safety This chapter deals with your own safety and the safety of the equipment operators.!

More information

RKSlimlift / EM. Two-stage lifting column

RKSlimlift / EM. Two-stage lifting column RKSlimlift / EM Two-stage lifting column Two-stage lifting column - RKSlimlift / EM Rod-shaped design and extremely quiet operation RKSlimlift RKSlimlift EM 4 fixing threads 9Simple 9 connection Drive

More information

Technical operating data

Technical operating data www.osram.com SubstiTUBE Advanced UO UN ST8AU-1.5m-24W-UN Preliminary Datasheet Innovative LED-lamp, easy and safe to use in CCG and ECG installations as direct retrofit. Energy saving potential of up

More information

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video

More information

Documentation. Magnetic Encoder System (MES) Version: Date:

Documentation. Magnetic Encoder System (MES) Version: Date: Documentation Magnetic Encoder System (MES) Version: Date: 1.1 2016-02-26 Table of content Table of content 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Intended use... 5 1.3 Documentation

More information

3.22 Finalize exact specifications of 3D printed parts.

3.22 Finalize exact specifications of 3D printed parts. 3.22 Finalize exact specifications of 3D printed parts. This is the part that connect between the main tube and the phone holder, it needs to be able to - Fit into the main tube perfectly - This part need

More information

3 SLiC Aerial Closure with Rubber End Seal

3 SLiC Aerial Closure with Rubber End Seal 3 Aerial Closure with Rubber End Seal Instructions 1.0 General 1.1 This instruction bulletin describes the assembly of the 3M Aerial Closure with external bonding hanger brackets. These closures are suitable

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

Arc Detector for Remote Detection of Dangerous Arcs on the DC Side of PV Plants

Arc Detector for Remote Detection of Dangerous Arcs on the DC Side of PV Plants 1 Arc Detector for Remote Detection of Dangerous Arcs on the DC Side of PV Plants Heinrich Haeberlin Berne University of Applied Sciences (BFH-TI), Division of Electrical- and Communication Engineering,

More information

About your Kobo ereader...6

About your Kobo ereader...6 User Guide Kobo Touch 2.0 User Guide Table of Contents About your Kobo ereader...6 Anatomy of your Kobo ereader...6 Charging your Kobo ereader...8 Charging your Kobo ereader with a wall adapter...9 Turning

More information

Technical operating data

Technical operating data www.osram.com SubstiTUBE Advanced UO UN ST8AU-1.2m-16W-UN Preliminary Datasheet Innovative LED-lamp, easy and safe to use in CCG and ECG installations as direct retrofit. Energy saving potential of up

More information

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control Series 3000 Model R-165A Audio/Video IF/RF Relay Panel Instruction Manual CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. Lyndonville NY 14098 www.monroe-electronics.com Table

More information

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1993 Specifications CSJ 0027-12-086, etc. SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of color

More information

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button.

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button. DIGITAL COLOR VIDEO INTERCOM SYSTEM The contractor shall supply, install, test and commission a modern Electronic Digital Color Video Entry Phone System of an approved manufacturer and design to facilitate

More information

Reference Manual. Notes 9/16 Series H

Reference Manual. Notes 9/16 Series H Reference Manual Notes 9/16 Series 173.01H Copyright notice The information in this document is subject to change without prior notice and does not represent a commitment on the part of Q-MATIC AB. All

More information

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

National Wire and Cable and National Cable Molding Headquarters Los Angeles California National Wire and Cable and National Cable Molding Headquarters Los Angeles California CAPABILITIES Medical Business Machines Communications Equipment Computer Equipment Audio Systems General Instrumentation

More information

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES FOR 75 OHM AND 75 OHM HD COAXIAL CONTACTS AND MODULES Table of Contents SECTION 1 RECEIVER CONTACT ASSEMBLY INSTRUCTIONS SECTION 2 ITA CONTACT

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

Service manual Cantano W/T

Service manual Cantano W/T Service manual Cantano W/T Here you will see everything that should be included in your Cantano package 2 Prerequisite: Placement and leveling of the drive 5 Setting up the motor and connecting it to the

More information

A KIND OF COAXIAL RESONATOR STRUCTURE WITH LOW MULTIPACTOR RISK. Engineering, University of Electronic Science and Technology of China, Sichuan, China

A KIND OF COAXIAL RESONATOR STRUCTURE WITH LOW MULTIPACTOR RISK. Engineering, University of Electronic Science and Technology of China, Sichuan, China Progress In Electromagnetics Research Letters, Vol. 39, 127 132, 2013 A KIND OF COAXIAL RESONATOR STRUCTURE WITH LOW MULTIPACTOR RISK Xumin Yu 1, 2, Xiaohong Tang 1, Juan Wang 2, Dan Tang 2, and Xinyang

More information

When you load media, you must place the roll onto the media hangers. You must use the correct media for the type of printing you require.

When you load media, you must place the roll onto the media hangers. You must use the correct media for the type of printing you require. Getting Started 13 When you load media, you must place the roll onto the media hangers. You must use the correct media for the type of printing you require. Preparing Media Whether your roll media is inside

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

DIN Connectors DIN06 E-03

DIN Connectors DIN06 E-03 DIN Connectors DIN0 E-0 Contents Introduction HOSIDEN DIN connectors are supplied to electronic equipment manufacturers both in Japan and overseas and are very well accepted because of high quality, a

More information

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide GB05-7 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2013 In the interests of development, information

More information

www.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~

More information

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING: MSB12906121MAN UK English INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING: Ensure that the Matsuko Switchbox is switched off at the mains before you attempt

More information

G.R.A.S. Sound & Vibration

G.R.A.S. Sound & Vibration Instruction Manual Single-channel Low-noise Measuring System consisting of: ½-inch Low-noise Level Microphone System Type 40HH and Power Module Type 12HF 40HH 12HF G.R.A.S. Sound & Vibration Skovlytoften

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

120cm (4x36 Watt) incl. Splitter Instruction Manual

120cm (4x36 Watt) incl. Splitter Instruction Manual 120cm incl. Splitter Instruction Manual Table of contents 1 Description of Device and Functions... 3 1.1 Safety Instructions... 4 2 Preparation and Installation... 5 2.1 Mounting... 5 2.2 Secure the...

More information

3M Better Buried Closures

3M Better Buried Closures 3M Better Buried Closures Instructions March 2016 78-0015-2945-8-A Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Closure Selection Guide... 4 4.0 LHS End Cap Installation... 5 5.0 Cable Preparations...

More information

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features Description Page 1 of 8 The EM1 is a transmissive optical encoder module. This module is designed to detect rotary or linear position when used together with a codewheel or linear strip. The EM1 consists

More information